Search NASA⌕ Search

SEARCH · Search NASA

Results for “pump efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Thermalization of Fluorescent Protein Exciton–Polaritons at Room Temperature

Fluorescent proteins (FPs) have recently emerged as a serious contender for realizing ultralow threshold room temperature exciton–polariton condensation and lasing. Here, this contribution investigates the thermalization of FP microcavity exciton–polaritons upon optical pumping under ambient conditions. Polariton cooling is realized using a new FP molecule, called mScarlet, coupled strongly to the optical modes in a Fabry–Pérot cavity. Interestingly, at the threshold excitation energy (fluence) of ≈9 nJ per pulse (15.6 mJ cm –2 ), an effective temperature is observed, T eff ≈ 350 ± 35 K close to the lattice temperature indicative of strongly thermalized exciton–polaritons at equilibrium. This efficient thermalization results from the interplay of radiative pumping facilitated by the energetics of the lower polariton branch and the cavity Q-factor. Direct evidence for dramatic switching from an equilibrium state into a metastable state is observed for the organic cavity polariton device at room temperature via deviation from the Maxwell–Boltzmann statistics at k || = 0 above the threshold. Thermalized polariton gases in organic systems at equilibrium hold substantial promise for designing room temperature polaritonic circuits, switches, and lattices for analog simulation.

36 MATERIALS SCIENCE↗

Improving Ventilation and Saving Energy: Final Report on Indoor Environmental Quality and Energy Monitoring in Sixteen Relocatable Classrooms

An improved HVAC system for portable classrooms was specified to address key problems in existing units. These included low energy efficiency, poor control of and provision for adequate ventilation, and excessive acoustic noise. Working with industry, a prototype improved heat pump air conditioner was developed to meet the specification. A one-year measurement-intensive field-test of ten of these IHPAC systems was conducted in occupied classrooms in two distinct California climates. These measurements are compared to those made in parallel in side by side portable classrooms equipped with standard 10 SEER heat pump air conditioner equipment. The IHPAC units were found to work as designed, providing predicted annual energy efficiency improvements of about 36 percent to 42 percent across California's climate zones, relative to 10 SEER units. Classroom ventilation was vastly improved as evidenced by far lower indoor minus outdoor CO2 concentrations. TheIHPAC units were found to provide ventilation that meets both California State energy and occupational codes and the ASHRAE minimum ventilation requirements; the classrooms equipped with the 10 SEER equipment universally did not meet these targets. The IHPAC system provided a major improvement in indoor acoustic conditions. HVAC system generated background noise was reduced in fan-only and fan and compressor modes, reducing the nose levels to better than the design objective of 45 dB(A), and acceptable for additional design points by the Collaborative on High Performance Schools. The IHPAC provided superior ventilation, with indoor minus outdoor CO2 concentrations that showed that the Title 24 minimum ventilation requirement of 15 CFM per occupant was nearly always being met. The opposite was found in the classrooms utilizing the 10 SEER system, where the indoor minus outdoor CO2 concentrations frequently exceeded levels that reflect inadequate ventilation. Improved ventilation conditions in the IHPAC lead to effective removal of volatile organic compounds and aldehydes, on average lowering the concentrations by 57 percent relative to the levels in the 10 SEER classrooms. The average IHPAC to 10 SEER formaldehyde ratio was about 67 percent, indicating only a 33 percent reduction of this compound in indoor air. The IHPAC thermal control system provided less variability in occupied classroom temperature than the 10 SEER thermostats. The average room temperatures in all seasons tended to be slightly lower in the IHPAC classrooms, often below the lower limit of the ASHRAE 55 thermal comfort band. State-wide and national energy modeling provided conservative estimates of potential energy savings by use of the IHPAC system that would provide payback a the range of time far lower than the lifetime of the equipment. Assuming electricity costs of $0.15/kWh, the perclassroom range of savings is from about $85 to $195 per year in California, and about $89 to $250 per year in the U.S., depending upon the city. These modelsdid not include the non-energy benefits to the classrooms including better air quality and acoustic conditions that could lead to improved health and learning in school. Market connection efforts that were part of the study give all indication that this has been a very successful project. The successes include the specification of the IHPAC equipment in the CHPS portable classroom standards, the release of a commercial product based on the standards that is now being installed in schools around the U.S., and the fact that a public utility company is currently considering the addition of the technology to its customer incentive program. These successes indicate that the IHPAC may reach its potential to improve ventilation and save energy in classrooms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Jet impingement heat transfer enhancement for the GPU-3 Stirling engine

A computer model of the combustion-gas-side heat transfer was developed to predict the effects of a jet impingement system and the possible range of improvements available. Using low temperature (315 C (600 F)) pretest data in an updated model, a high temperature silicon carbide jet impingement heat transfer system was designed and fabricated. The system model predicted that at the theoretical maximum limit, jet impingement enhanced heat transfer can: (1) reduce the flame temperature by 275 C (500 F); (2) reduce the exhaust temperature by 110 C (200 F); and (3) increase the overall heat into the working fluid by 10%, all for an increase in required pumping power of less than 0.5% of the engine power output. Initial tests on the GPU-3 Stirling engine at NASA-Lewis demonstrated that the jet impingement system increased the engine output power and efficiency by 5% - 8% with no measurable increase in pumping power. The overall heat transfer coefficient was increased by 65% for the maximum power point of the tests.

Johnson, D. C.↗

Multiobjective Optimization of Rocket Engine Pumps Using Evolutionary Algorithm

A design optimization method for turbopumps of cryogenic rocket engines has been developed. Multiobjective Evolutionary Algorithm (MOEA) is used for multiobjective pump design optimizations. Performances of design candidates are evaluated by using the meanline pump flow modeling method based on the Euler turbine equation coupled with empirical correlations for rotor efficiency. To demonstrate the feasibility of the present approach, a single stage centrifugal pump design and multistage pump design optimizations are presented. In both cases, the present method obtains very reasonable Pareto-optimal solutions that include some designs outperforming the original design in total head while reducing input power by one percent. Detailed observation of the design results also reveals some important design criteria for turbopumps in cryogenic rocket engines. These results demonstrate the feasibility of the EA-based design optimization method in this field.

Oyama, Akira↗

Rebuilding It Better: Greensburg, Kansas. Kiowa County Courthouse (Brochure)

This document is one in a series of five that showcases the green, sustainable buildings in Greensburg, Kansas. The Kiowa County Courthouse was one of only two buildings left standing after the tornado, which allowed the building to be renovated and refurbished rather than torn down.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Model to Evaluate Thermal Energy Storage Integrated with Air Source Heat Pumps: Preprint

Full decarbonization in buildings requires the replacement of combustion appliances with electric ones, and air source heat pumps (ASHP) are a candidate alternative. However, technical limitations, such as the efficiency decrease when operating in cold weather, limit their adoption in the global heating market. Among several options to improve ASHP efficiency operating in colder climates, thermal energy storage (TES) has been considered, as it may provide heating when it is cold and shift ASHP operation to times when the weather is warmer. It may also take advantage of time of use electricity rates and support defrosting when necessary. The evaluation of ASHP-TES systems, however, is still limited because traditional metrics do not capture their full economic and environmental benefits. In this work, a python framework is presented to model the ASHP with and without the presence of TES. Metrics are proposed to analyze the system performance in terms of costs, equivalent CO2 emission, and efficiency metrics to evaluate and compare alternative systems. Model validation against experimental data obtained for a commercial heat pump is provided, as well as an application example using Denver, Colorado, to highlight the model capabilities.

cold climate↗

Heralding efficiency and correlated-mode coupling of near-IR fiber-coupled photon pairs

We report on a systematic experimental study of heralding efficiency and generation rate of telecom-band infrared photon pairs generated by spontaneous parametric down-conversion and coupled to single mode optical fibers. We define the correlated-mode coupling efficiency--an inherent source efficiency--and explain its relation to heralding efficiency. For our experiment, we developed a reconfigurable computer controlled pump-beam and collection-mode optical apparatus which we used to measure the generation rate and correlated-mode coupling efficiency. The use of low-noise, high-efficiency superconducting-nanowire single-photon-detectors in this setup allowed us to explore focus configurations with low overall photon flux. The measured data agree well with theory and we demonstrated a correlated-mode coupling efficiency of 97%±2%, which is the highest efficiency yet achieved for this type of system. These results confirm theoretical treatments and demonstrate that very high overall heralding efficiencies can, in principle, be achieved in quantum optical systems. We expect that these results and techniques will be widely incorporated into future systems that require, or benefit from, a high heralding efficiency.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Generation of green frequency comb from chirped χ{sup (2)} nonlinear photonic crystals

Spectrally broad frequency comb generation over 510–555 nm range was reported on chirped quasi-phase-matching (QPM) χ{sup (2)} nonlinear photonic crystals of 12 mm length with periodicity stepwise increased from 5.9 μm to 7.1 μm. When pumped with nanosecond infrared (IR) frequency comb derived from a QPM optical parametric oscillator (OPO) and spanned over 1040 nm to 1090 nm wavelength range, the 520 nm to 545 nm up-converted green spectra were shown to consist of contributions from (a) second-harmonic generation among the signal or the idler modes, and (b) sum-frequency generation (SFG) from the neighboring pairs of the signal or the idler modes. These mechanisms led the up-converted green frequency comb to have the same mode spacing of 450 GHz as that in the IR-OPO pump comb. As the pump was further detuned from the aforementioned near-degeneracy point and moved toward the signal (1020–1040 nm) and the idler (1090–1110 nm) spectral range, the above QPM parametric processes were preserved in the chirped QPM devices to support up-converted green generation in the 510–520 nm and the 545–555 nm spectral regime. Additional 530–535 nm green spectral generation was also observed due to concurrence of multi-wavelength SFG processes between the (signal, idler) mode pairs. These mechanisms facilitate the chirped QPM device to support a single-pass up-conversion efficiency ∼10% when subject to an IR-OPO pump comb with 200 mW average power operated near- or off- the degeneracy point.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Antiferromagnetic Parametric Resonance Driven by Voltage-Controlled Magnetic Anisotropy

Voltage-controlled magnetic anisotropy (VCMA) is a low-energy alternative to manipulate the ferromagnetic state, which has been recently also considered in antiferromagnets (AFMs). Here, we theoretically demonstrate that VCMA can be used to excite linear and parametric resonant modes in easy-axis AFMs with perpendicular anisotropy, thus opening the way for an efficient electrical control of the Néel vector and for the detection of high-frequency dynamics. Our work leads to two key results: (i) VCMA parametric pumping experiences the so-called “exchange enhancement” of the coupling efficiency and, thus, is 1–2 orders of magnitude more efficient than microwave magnetic fields or spin-orbit torques, and (ii) it also allows for zero-field parametric resonance, which cannot be achieved by other parametric pumping mechanisms in AFMs with an out-of-plane easy axis. Therefore, we demonstrate that VCMA parametric pumping is the most promising method for coherent excitation and manipulation of AFM order in perpendicular easy-axis AFMs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

ResStock Measure Documentation: Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER) With Light Envelope Improvements

This report is part of series describing a variety of different ResStock™ measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER) with Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Deployable Element Ultra-High Vacuum Pump

Advancing Ultra High Vacuum (UHV) Pumping Technology: The deployable UHV pump team has designed a theoretical model to boost efficiency in high vacuum environments. Traditional systems face challenges with random molecular motion. The innovative windmill design, using titanium sublimation technology, reduces randomness by deploying a gettering surface that actively captures particles. This marks a notable advancement in UHV pumping technology.

43 PARTICLE ACCELERATORS↗

Field Demonstration and Adoption Impacts of an Affordable Thermoelectric Heat Pump

This study presents the design, field validation, and utility impacts of an air source heat pump that uses thermoelectric (TE) technology to provide supplemental heating at outside air temperatures below 17°F. Conventional heat pumps experience reduced heating capacity and COP at low outdoor temperatures due to the temperature difference between the source and demand sides of the vapor compression cycle. Consequently, during colder months, supplemental heating such as electric resistance or natural gas furnace is often needed to provide additional warmth, which increases the overall equipment and energy costs. To address this challenge, a TE subcooler (an array of solid-state, thermoelectric modules that provides heat pumping using non-vapor compression technique) is fabricated and integrated with the vapor compression cycle of a conventional air-source heat pump. In colder ambient conditions, TE subcooler exchanges heat with the refrigerant to provide additional subcooling, thereby enhancing the capacity of the heat pump. The operation of thermoelectric-integrated heat pump was demonstrated in an occupied single-family home in Nashville, TN. The TE subcooler increased the system’s heating capacity at 15°F outdoor temperature by 25–30% and reduced electricity demand by 10%. It also met the heating load in the house without supplemental electric resistance down to 5°F outdoors, delivering the additional heat at nearly 80% greater efficiency compared to electric resistance heating. With a modest first cost increment of 10–15% over conventional single-speed heat pumps, this approach offers a promising, energy-efficient solution to accelerate residential heat pump adoption in the U.S.

KRISHNAMOORTHY, Sreenidhi [Electric Power Research↗

Optical Sidebands Multiplier

Optical sidebands have been generated with relative frequency tens to hundreds of GHz by using optical sidebands that are generated in a cascade process in high-quality optical resonators with Kerr nonlinearity, such as whispering gallery mode (WGM) resonators. For this purpose, the WGM resonator needs to be optically pumped at two frequencies matching its resonances. These two optical components can be one or several free spectral ranges (FSRs), equal to approximately 12 GHz, in this example, apart from each other, and can be easily derived from a monochromatic pump with an ordinary EOM (electro-optic modulation) operating at half the FSR frequency. With sufficient nonlinearity, an optical cascade process will convert the two pump frequencies into a comb-like structure extending many FSRs around the carrier frequency. This has a demonstratively efficient frequency conversion of this type with only a few milliwatt optical pump power. The concept of using Kerr nonlinearity in a resonator for non-degenerate wave mixing has been discussed before, but it was a common belief that this was a weak process requiring very high peak powers to be observable. It was not thought possible for this approach to compete with electro-optical modulators in CW applications, especially those at lower optical powers. By using the high-Q WGM resonators, the effective Kerr nonlinearity can be made so high that, using even weak seeding bands available from a conventional EOM, one can effectively multiply the optical sidebands, extending them into an otherwise inaccessible frequency range.

Strekalov, Dmitry V.↗

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements

This report is part of series describing a variety of different ResStock(TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

15 GEOTHERMAL ENERGY↗

Virtual refrigerant charge sensing algorithm for residential CO₂ heat pumps

Natural refrigerants are increasingly adopted in next-generation heat pump systems, among which CO₂ heat pumps have attracted significant attention. However, due to their high operating pressures, the leakage risk is higher, resulting in undercharge conditions and degraded heat pump performance. Thus, developing an accurate refrigerant charge level detection technique is necessary to guarantee safe and efficient operation. Although virtual refrigerant charge (VRC) level calculation algorithms for CO₂ heat pumps exist, they typically rely on empirically selected features without a systematic selection framework, leading to multicollinearity and potential overfitting, which limit their prediction accuracy and generalizability. To address these issues, this study proposes a VRC algorithm framework with a systematic feature selection method that identifies physically meaningful and statistically significant features, and is applied using a residential CO₂ heat pump as a case study. The method is extended from previous work on conventional refrigerants to account for charge behavior in CO₂ gas coolers. The selected features include gas cooler outlet density, evaporator pressure, and superheat temperature. The results demonstrate that the proposed feature selection method significantly improves prediction accuracy compared to existing VRC approaches. A relatively small training dataset (∼30 samples) is sufficient for feature identification and model development. The developed algorithm achieves less than 3% prediction error under both undercharge and overcharge conditions, representing reductions of 46.7% and 35.3% compared to two recent reference VRC algorithms for transcritical CO₂ heat pumps reported in the literature. The proposed algorithm and feature selection method enhance leakage detection capability, facilitate the deployment of CO₂ heat pump systems, and contribute to reduced energy waste and maintenance costs.

Guo, Fangzhou [Lawrence Berkeley National Laborato↗

Efficient Dual Head Nd:YAG 100mJ Oscillator for Remote Sensing

A diode pumped, Nd:YAG laser producing 100 mJ Q-switched pulses and employing a dual-pump head scheme in an unstable resonator configuration is described. Each head contains a side pumped zig-zag slab and four 6-bar QCW 808 nm diodes arrays which are de-rated 23%. Denoting 'z' as the lasing axis, the pump directions were along the x-axis in one head and the y-axis in the other, producing a circularized thermal lens, more typical in laser rod-based cavities. The dual head design's effective thermal lens is now corrected with a proper HR mirror curvature selection. This laser has demonstrated over 100 mJ output with high optical efficiency (24%), good TEM(sub 00) beam quality, and high pointing stability.

Coyle, Donald B.↗

Solar-pumped lasers for space power transmission

Multi-Megawatt CW solar-pumped lasers appear to be technologically feasible for space power transmission in the 1990s time frame. A new concept for a solar-pumped laser is presented which utilizes an intermediate black body cavity to provide a uniform optical pumping environment for the lasant, either CO or CO2. Reradiation losses are minimized with resulting high efficiency operation. A 1 MW output laser may weigh as little as 8000 kg including solar collector, black body cavity, laser cavity and ducts, pumps, power systems and waste heat radiator. The efficiency of such a system will be on the order of 10 to 20%. Details of the new concept, laser design, comparison to competing solar-powered lasers and applications to a laser solar power satellite (SPS) concept are presented.

Taussig, R.↗

All-optical depletion of dark excitons from a semiconductor quantum dot

Semiconductor quantum dots are considered to be the leading venue for fabricating on-demand sources of single photons. However, the generation of long-lived dark excitons imposes significant limits on the efficiency of these sources. We demonstrate a technique that optically pumps the dark exciton population and converts it to a bright exciton population, using intermediate excited biexciton states. We show experimentally that our method considerably reduces the dark exciton population while doubling the triggered bright exciton emission, approaching thereby near-unit fidelity of quantum dot depletion.

77 NANOSCIENCE AND NANOTECHNOLOGY↗