Search NASA⌕ Search

SEARCH · Search NASA

Results for “resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Super-Resolution Study of Polymer Mobility Fluctuations near c *

Nanoscale dynamic heterogeneities in synthetic polymer solutions are detected using super-resolution optical microscopy. To this end, we map concentration fluctuations in polystyrene–toluene solutions with spatial resolution below the diffraction limit, focusing on critical fluctuations near the polymer overlap concentration, c*. Two-photon super-resolution microscopy was adapted to be applicable in an organic solvent, and a home-built STED-FCS system with stimulated emission depletion (STED) was used to perform fluorescence correlation spectroscopy (FCS). The polystyrene serving as the tracer probe (670 kg mol –1 , radius of gyration R G ≈ 35 nm, end-labeled with a bodipy derivative chromophore) was dissolved in toluene at room temperature (good solvent) and mixed with matrix polystyrene (3,840 kg mol –1 , R G ≈ 97 nm, M w /M n = 1.04) whose concentration was varied from dilute to more than 10c*. Whereas for dilute solutions the intensity–intensity correlation function follows a single diffusion process, it splits starting at c* to imply an additional relaxation process provided that the experimental focal area does not greatly exceed the polymer blob size. We identify the slower mode as self-diffusion and the increasingly rapid mode as correlated segment fluctuations that reflect the cooperative diffusion coefficient, D coop . These real-space measurements find quantitative agreement between correlation lengths inferred from dynamic measurements and those from determining the limit below which diffusion coefficients are independent of spot size. Furthermore, this study is considered to illustrate the potential of importing into polymer science the techniques of super-resolution imaging.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Resolution Dependence and Rossby Wave Modulation of Atmospheric Rivers in an Aquaplanet Model

Atmospheric rivers (ARs) are examined in a set of aquaplanet simulations using the Model for Prediction Across Scales dynamical core run at multiple horizontal resolutions, namely, 240, 120, and 60 km. As the resolution is increased, there is an increase in the occurrence of long—lasting ARs. At the same time there is also an increase in the local finite–amplitude wave activity (LWA) of upper–tropospheric absolute vorticity, a measure for Rossby wave phase and amplitude that is closely linked with wave breaking. Consistent with the notion that changes in ARs are driven by midlatitude dynamics, a strong relationship is identified between ARs and the equatorward component of LWA. Here, a logistic regression model is used to quantify the probability of AR occurrence based solely on LWA and explains most of the change in AR frequency with resolution. LWA is a diagnostic that may be easily applied to the broadly available output of phase 6 of the Coupled Model Intercomparison project and other model simulations, thus enabling scientists to infer AR and Rossby wave characteristics. AR characteristics, in particular, require higher–resolution moisture and winds at multiple levels that are not always easily available.

54 ENVIRONMENTAL SCIENCES↗

Multiscale Simulation of Precipitation Over East Asia by Variable Resolution CAM-MPAS

This study evaluates the precipitation over East Asia simulated by the variable resolution CAM-MPAS featuring the Model for Prediction Across Scales (MPAS) atmospheric dynamical core coupled with the physics parameterizations of the Community Atmosphere Model (CAM) version 5.4. Two CAM-MPAS experiments, one with a global quasi-uniform resolution mesh of 120 km (MPAS-UR) and the other with a variable resolution mesh of 30 to 120 km refined over East Asia (MPAS-VR), are conducted from 1989 to 2005 following the Atmospheric Model Intercomparison Project protocol. Two regional climate model simulations at ~25 km resolution from the Coordinated Regional Downscaling Experiment East Asia second plan are also analyzed for comparison. Results show that CAM-MPAS performs better than the selected regional models in simulating the precipitation climatology over East Asia. Compared with MPAS-UR, MPAS-VR with refinement over East Asia better simulates the precipitation over and around the Tibetan Plateau (TP), the frequency distribution of light, moderate, and heavy precipitation in various regions of China, and the interannual precipitation pattern associated with the East Asian summer monsoon. The improvements in MPAS-VR relative to MPAS-UR largely come from the decreased grid spacing rather than the use of finer-scale terrain information. Particularly, decreased grid spacing is more essential for simulating the precipitation magnitude over TP and the location of peak precipitation south of TP, likely due to the better resolved physical and dynamical processes associated with orographic precipitation. The 30-120 km CAM-MPAS model is shown to be a promising tool for precipitation simulation over East Asia.

54 ENVIRONMENTAL SCIENCES↗

2D perovskite-based high spatial resolution X-ray detectors

Abstract X-ray radiography is the most widely used imaging technique with applications encompassing medical and industrial imaging, homeland security, and materials research. Although a significant amount of research and development has gone into improving the spatial resolution of the current state-of-the-art indirect X-ray detectors, it is still limited by the detector thickness and microcolumnar structure quality. This paper demonstrates high spatial resolution X-ray imaging with solution-processable two-dimensional hybrid perovskite single-crystal scintillators grown inside microcapillary channels as small as 20 µm. These highly scalable non-hygroscopic detectors demonstrate excellent spatial resolution similar to the direct X-ray detectors. X-ray imaging results of a camera constructed using this scintillator show Modulation Transfer Function values significantly better than the current state-of-the-art X-ray detectors. These structured detectors open up a new era of low-cost large-area ultrahigh spatial resolution high frame rate X-ray imaging with numerous applications.

2D perovskite↗

Spectral resolution measurement of an x-ray imaging crystal spectrometer for KSTAR

A spectral resolution measurement of the x-ray imaging crystal spectrometer for the Korea Superconducting Tokamak Advanced Research machine utilizing a segmented position-sensitive detector and time-to-digital converter based delay-line readout electronics was performed by using an x-ray tube in a laboratory. The measured spectral resolution is about 12 600, which means the actual energy resolution is 0.32 eV for the x-ray tube's bremsstrahlung peak energy of 4 keV. The results from the spectral resolution measurement are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte-Carlo studies of the angular resolution of a future Cherenkov gamma-ray telescope

The current generation of Imaging Atmospheric telescopes (IACTs) has demonstrated the power of this observational technique, providing high sensitivity and an angular resolution of {approx}0.1 deg. per event above an energy threshold of {approx}100 GeV. Planned future arrays of IACTs such as AGIS or CTA are aiming at significantly improving the angular resolution. Preliminary results have shown that values down to {approx}1' might be achievable. Here we present the results of Monte-Carlo simulations that aim to exploring the limits of angular resolution for next generation IACTs and investigate how the resolution can be optimised by changes to array and telescope parameters such as the number of pixel in the camera, the field of view of the camera, the angular pixel size, the mirror size, and also the telescope separation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microfabrication of High Resolution X-ray Magnetic Calorimeters

Metallic magnetic calorimeter (MMC) is one of the most promising x-ray detector technologies for providing the very high energy resolution needed for future astronomical x-ray imaging spectroscopy. For this purpose, we have developed micro-fabricated 5x5 arrays of MMC of which each individual pixel has excellent energy resolution as good as 3.4 eV at 6 keV x-ray. Here we report on the fabrication techniques developed to achieve good resolution and high efficiency. These include: processing of a thin insulation layer for strong magnetic coupling between the AuEr sensor film and the niobium pick-up coil; production of overhanging absorbers for enhanced efficiency of x-ray absorption; fabrication on SiN membranes to minimize the effects on energy resolution from athermal phonon loss. We have also improved the deposition of the magnetic sensor film such that the film magnetization is nearly completely that is expected from the AuEr sputter target bulk material. In addition, we have included a study of a positional sensitive design, the Hydra design, which allows thermal coupling of four absorbers to a common MMC sensor and circuit.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high resolution, broad energy acceptance spectrometer for laser wakefield acceleration experiments

Laser wakefield experiments present a unique challenge in measuring the resulting electron energy properties due to the large energy range of interest, typically several 100 MeV, and the large electron beam divergence and pointing jitter >1 mrad. In many experiments the energy resolution and accuracy are limited by the convolved transverse spot size and pointing jitter of the beam. In this paper we present an electron energy spectrometer consisting of two magnets designed specifically for laser wakefield experiments. In the primary magnet the field is produced by permanent magnets. A second optional electromagnet can be used to obtain better resolution for electron energies above 75 MeV. The spectrometer has an acceptance of 2.5-400 MeV (E{sub max}/E{sub min}>100) with a resolution of better than 1% rms for electron energies above 25 MeV. This high resolution is achieved by refocusing electrons in the energy plane and without any postprocessing image deconvolution. Finally, the spectrometer employs two complimentary detection mechanisms: (1) absolutely calibrated scintillation screens imaged by cameras outside the vacuum chamber and (2) an array of scintillating fibers coupled to a low-noise charge-coupled device.

43 PARTICLE ACCELERATORS↗

Note: Direct measurement of the point-to-point resolution for microns-thick specimens in the ultrahigh-voltage electron microscope

We report on a direct measurement method and results of the point-to-point resolution for microns-thick amorphous specimens in the ultrahigh-voltage electron microscope (ultra-HVEM). We first obtain the ultra-HVEM images of nanometer gold particles with different sizes on the top surfaces of the thick epoxy-resin specimens. Based on the Rayleigh criterion, the point-to-point resolution is then determined as the minimum distance between centers of two resolvable tangent gold particles. Some values of resolution are accordingly acquired for the specimens with different thicknesses at the accelerating voltage of 2 MV, for example, 18.5 nm and 28.4 nm for the 5 {mu}m and 8 {mu}m thick epoxy-resin specimens, respectively. The presented method and results provide a reliable and useful approach to quantifying and comparing the achievable spatial resolution for the thick specimens imaged in the mode of transmission electron including the scanning transmission electron microscope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computer simulation on spatial resolution of X-ray bright-field imaging by dynamical diffraction theory for a Laue-case crystal analyzer

Recently, dark-field imaging (DFI) and bright-field imaging (BFI) have been proposed and applied to visualize X-ray refraction effects yielded in biomedical objects. In order to clarify the spatial resolution due to a crystal analyzer in Laue geometry, a program based on the Takagi-Taupin equation was modified to be used for carrying out simulations to evaluate the spatial resolution of images coming into a Laue angular analyzer (LAA). The calculation was done with a perfect plane wave for diffraction wave-fields, which corresponded to BFI, under the conditions of 35 keV and a diffraction index 440 for a 2100 {mu}m thick LAA. As a result, the spatial resolution along the g-vector direction showed approximately 37.5 {mu}m. 126 {mu}m-thick LAA showed a spatial resolution better than 3.1 {mu}m under the conditions of 13.7 keV and a diffraction index 220.

36 MATERIALS SCIENCE↗

Investigation of a high spatial resolution method based on polar coordinate maximum entropy method for analyzing electron density fluctuation data measured by laser phase contrast

Laser phase contrast is a powerful diagnostic method to determine the spatial distribution of electron density fluctuations in magnetically confined plasmas, although its applicability depends on magnetic field configurations. The spatial resolution of fluctuations is linked with the resolution of the propagation direction that is derived from the two-dimensional spectral analysis of the wavenumber for the fluctuations. The method was applied to fluctuation measurements in a compact helical system. In order to improve the resolution of the propagation direction with a relatively small number of data points, the maximum entropy method with polar coordinates was employed. A spatial resolution of the order of 1 cm was obtained, which is satisfactory in a plasma with a 20 cm minor radius.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First results from the J-TEXT high-resolution three-wave polarimeter-interferometer

A laser-based far-infrared polarimeter-interferometer system utilizing the three-wave technique has been implemented on the J-TEXT tokamak. The polarimeter determines the Faraday effect by measuring the phase difference between two collinear, counter-rotating, circularly polarized laser beams. The first results of the polarimeter-interferometer designed for J-TEXT have been obtained in the most recent J-TEXT experimental campaign. Simultaneous polarimetric and interferometric measurement is achieved, with phase resolution up to 0.1 Degree-Sign , at bandwidth of 50 kHz. The temporal resolution, which is dependent on the laser's frequency offset, is {approx}1 {mu}s. Continual spatial measurement covering 45 cm (80% of the plasma cross-section) is realized by utilizing 1D parabolic beam expansion optics. Three initial test chords are installed and future plans call for expansion up to 30 chords with 1.5 cm chord spacing, providing high spatial resolution for measurement of electron density and current density profiles. Reliability of both polarimetric and interferometric measurement is confirmed by comparison with computation and data from a hydrocyanic acid (HCN) interferometer. With the high temporal and phase resolution, perturbations associated with the sawtooth cycle and MHD activity have been observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hard x-ray scanning microscopy with coherent radiation: Beyond the resolution of conventional x-ray microscopes

We demonstrate x-ray scanning coherent diffraction microscopy (ptychography) with 10 nm spatial resolution, clearly exceeding the resolution limits of conventional hard x-ray microscopy. The spatial resolution in a ptychogram is shown to depend on the shape (structure factor) of a feature and can vary for different features in the object. In addition, the resolution and contrast are shown to increase with increasing coherent fluence. For an optimal ptychographic x-ray microscope, this implies a source with highest possible brilliance and an x-ray optic with a large numerical aperture to generate the optimal probe beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatial resolution of synchrotron x-ray microtomography in high energy range: Effect of x-ray energy and sample-to-detector distance

Spatial resolution of three-dimensional images obtained by synchrotron X-ray microtomography technique is evaluated using cyclic bar patterns machined on a steel wire. Influences of X-ray energy and the sample-to-detector distance on spatial resolution were investigated. High X-ray energies of 33-78 keV are applied due to the high X-ray absorption of transition metals. Best spatial resolution of about 1.2 {mu}m pitch was observed at the sample-to-detector distance range of 20-110 mm and at the energy range of 68-78 keV. Several factors such as X-ray scattering and diffraction phenomena affecting the degradation of spatial resolution are also discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The material dependence of temperature measurement resolution in thermal scanning electron microscopy

Thermal scanning electron microscopy is a recently developed temperature mapping technique based on thermal diffuse scattering in electron backscatter diffraction in a scanning electron microscope. It provides nano-scale and non-contact temperature mapping capabilities. Due to the specific temperature sensitive mechanism inherent to this technique, the temperature resolution is highly material dependent. A thorough investigation of what material properties affect the temperature resolution is important for realizing the inherent temperature resolution limit for each material. In this paper, three material dependent parameters-the Debye-Waller B-factor temperature sensitivity, backscatter yield, and lattice constant-are shown to control the temperature resolution.

36 MATERIALS SCIENCE↗

Experimental energy resolution of a paracentric hemispherical deflector analyzer for different entry positions and bias

A specially designed hemispherical deflector analyzer (HDA) with 5-element input lens having a movable entry position R{sub 0} suitable for electron energy analysis in atomic collisions was constructed and tested. The energy resolution of the HDA was experimentally determined for three different entry positions R{sub 0}= 84, 100, 112 mm as a function of the nominal entry potential V(R{sub 0}) under pre-retardation conditions. The resolution for the (conventional) entry at the mean radius R{sub 0}= 100 mm was found to be a factor of 1.6-2 times worse than the resolution for the two (paracentric) positions R{sub 0}= 84 and 112 mm at particular values of V(R{sub 0}). These results provide the first experimental verification and a proof of principle of the utility of such a paracentric HDA, while demonstrating its advantages over the conventional HDA: greater dispersion with reduced angular aberrations resulting in better energy resolution without the use of any additional fringing field correction electrodes. Supporting simulations of the entire lens plus HDA spectrometer are also provided and mostly found to be within 20%-30% of experimental values. The paracentric HDA is expected to provide a lower cost and/or more compact alternative to the conventional HDA particularly useful in modern applications utilizing a position sensitive detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time resolution of a 1-inch cylindrical CeBr{sub 3} crystal at {sup 60}Co energies

We have measured time resolutions of a cylindrical CeBr{sub 3} scintillator of 1-inch in height and 1-inch in diameter coupled to two different fast photomultiplier tubes, Hamamatsu R9779 and Photonis XP20D0, as a function of applied high voltages and different settings of a Constant Fraction Discriminator ORTEC 935. The time resolution was measured using a time-delayed coincidence set-up involving a fast reference detector. The best result of 119(2) ps at {sup 60}Co energies was obtained for the CeBr{sub 3} crystal coupled to the Hamamatsu PMT. This result is comparable to the resolution of 107 ps reported for a LaBr{sub 3}(Ce) crystal of the same size. For the coupling of the CeBr{sub 3} scintillator to the Photonis PMT we got the time resolution of 146(2) ps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy resolution and related charge carrier mobility in LaBr{sub 3}:Ce scintillators

The scintillation response of LaBr{sub 3}:Ce scintillation crystals was studied as function of temperature and Ce concentration with synchrotron X-rays between 9 keV and 100 keV. The results were analyzed using the theory of carrier transport in wide band gap semiconductors to gain new insights into charge carrier generation, diffusion, and capture mechanisms. Their influence on the efficiency of energy transfer and conversion from X-ray or γ-ray photon to optical photons and therefore on the energy resolution of lanthanum halide scintillators was studied. From this, we will propose that scattering of carriers by both the lattice phonons and by ionized impurities are key processes determining the temperature dependence of carrier mobility and ultimately the scintillation efficiency and energy resolution. When assuming about 100 ppm ionized impurity concentration in 0.2% Ce{sup 3+} doped LaBr{sub 3,} mobilities are such that we can reproduce the observed temperature dependence of the energy resolution, and in particular, the minimum in resolution near room temperature is reproduced.

36 MATERIALS SCIENCE↗