Search NASA⌕ Search

SEARCH · Search NASA

Results for “single photon source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Considerations about future hard x-ray area detectors

X-ray sources continue to advance in both intensity and temporal domains, thereby opening new ways to analyze the structure and properties of matter, provided that the resultant x-ray images can be efficiently and quantitatively recorded. In this perspective we focus on specific limitations of pixel area x-ray detectors. Although pixel area x-ray detectors have also advanced in recent years, many experiments are still detector limited. Specifically, there is need for detectors that can acquire successive images at GHz rates; detectors that can accurately measure both single photon and millions of photons per pixel in the same image at frame rates of hundreds of kHz; and detectors that efficiently capture images of very hard x-rays (20 keV to several hundred keV). The data volumes and data rates of state-of-the-art detection exceeds most practical data storage options and readout bandwidths, thereby necessitating on-line processing of data prior to, or in lieu of full frame readouts.

36 MATERIALS SCIENCE↗

Resonant enhanced multiphoton ionization studies of atomic oxygen

In resonant enhanced multiphoton ionization (REMPI), an atom absorbs several photons making a transition to a resonant intermediate state and subsequently ionizing out of it. With currently available tunable narrow-band lasers, the extreme sensitivity of REMPI to the specific arrangement of levels can be used to selectively probe minute amounts of a single species (atom) in a host of background material. Determination of the number density of atoms from the observed REMPI signal requires a knowledge of the multiphoton ionization cross sections. The REMPI of atomic oxygen was investigated through various excitation schemes that are feasible with available light sources. Using quantum defect theory (QDT) to estimate the various atomic parameters, the REMPI dynamics in atomic oxygen were studied incorporating the effects of saturation and a.c. Stark shifts. Results are presented for REMPI probabilities for excitation through various 2p(3) (4S sup o) np(3)P and 2p(3) (4S sup o) nf(3)F levels.

Dixit, S. N.↗

Two-dimensional-lattice-confined single-molecule-like aggregates

Intermolecular distance largely determines the optoelectronic properties of organic matter. Conventional organic luminescent molecules are commonly used either as aggregates or as single molecules that are diluted in a foreigner matrix. They have garnered great research interest in recent decades for a variety of applications, including light-emitting diodes, lasers and quantum technologies, among others. However, there is still a knowledge gap on how these molecules behave between the aggregation and dilution states. Here we report an unprecedented phase of molecular aggregate that forms in a two-dimensional hybrid perovskite superlattice with a near-equilibrium distance, which we refer to as a single-molecule-like aggregate (SMA). By implementing two-dimensional superlattices, the organic emitters are held in proximity, but, surprisingly, remain electronically isolated, thereby resulting in a near-unity photoluminescence quantum yield, akin to that of single molecules. Moreover, the emitters within the perovskite superlattices demonstrate strong alignment and dense packing resembling aggregates, allowing for the observation of robust directional emission, substantially enhanced radiative recombination and efficient lasing. Molecular dynamics simulations together with single-crystal structure analysis emphasize the critical role of the internal rotational and vibrational degrees of freedom of the molecules in the two-dimensional lattice for creating the exclusive SMA phase. Furthermore, this two-dimensional superlattice unifies the paradoxical properties of single molecules and aggregates, thus offering exciting possibilities for advanced spectroscopic and photonic applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design of a terahertz parametric oscillator based on a resonant cavity in a terahertz waveguide

We demonstrate ns-pulsed pumping of terahertz (THz) parametric oscillations in a quasi-triply resonant cavity in a THz waveguide. The THz waves, down converted through parametric interactions between the pump and signal waves at telecom frequencies, are confined to a GaP single mode ridge waveguide. By combining the THz waveguide with a quasi-triply resonant cavity, the nonlinear interactions can be enhanced. A low threshold pump intensity for parametric oscillations can be achieved in the cavity waveguide. The THz output power can be maximized by optimizing the quality factors of the cavity so that an optical to THz photon conversion efficiency, η{sub p}, of 0.35, which is near the quantum-limit level, can be attained. The proposed THz optical parametric oscillator can be utilized as an efficient and monochromatic THz source.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

FAR-ULTRAVIOLET OBSERVATIONS OF THE TAURUS-PERSEUS-AURIGA COMPLEX

We have constructed a far-ultraviolet (FUV) continuum map of the Taurus-Auriga-Perseus complex, one of the largest local associations of dark clouds, by merging the two data sets of Galaxy Evolution Explorer and FUV Imaging Spectrograph, which made observations at similar wavelengths. The FUV intensity varies significantly across the whole region, but the diffuse FUV continuum is dominated by dust scattering of stellar photons. A diffuse FUV background of {approx}1000 CU is observed, part of which may be attributable to the scattered photons of foreground FUV light, located in front of the thick clouds. The fluorescent emission of molecular hydrogen constitutes {approx}10% of the total FUV intensity throughout the region, generally proportional to the local continuum level. We have developed a Monte Carlo radiative transfer code and applied it to the present clouds complex to obtain the optical properties of dust grains and the geometrical structures of the clouds. The albedo and the phase function asymmetry factor were estimated to be 0.42{sup +0.05}{sub -0.05}, and 0.47{sup +0.11}{sub -0.27}, respectively, in accordance with theoretical estimations as well as recent observations. The distance and thickness of the four prominent clouds in this complex were estimated using a single-slab model applied individually to each cloud. The results obtained were in good agreement with those from other observations of the Taurus cloud, as its geometrical structure is rather simple. For other clouds that were observed to have multiple components, the results gave distances and thicknesses encompassing all of the components of each cloud. The distance and thickness estimations were not crucially sensitive to the exact values of the albedo and the phase function asymmetry factor, while the locations of the bright field stars relative to the clouds as initial photon sources seem to be the most important factor in the process of fitting.

79 ASTRONOMY AND ASTROPHYSICS↗

Speckle correlation as a monitor of X-ray free-electron laser induced crystal lattice deformation

X-ray free-electron lasers (X-FELs) present new opportunities to study ultrafast lattice dynamics in complex materials. While the unprecedented source brilliance enables high fidelity measurement of structural dynamics, it also raises experimental challenges related to the understanding and control of beam-induced irreversible structural changes in samples that can ultimately impact the interpretation of experimental results. This is also important for designing reliable high performance X-ray optical components. In this work, X-FEL beam-induced lattice alterations are investigated by measuring the shot-to-shot evolution of near-Bragg coherent scattering from a single crystalline germanium sample. It is shown that X-ray photon correlation analysis of sequential speckle patterns measurements can be used to monitor the nature and extent of lattice rearrangements. Additionally, abrupt, irreversible changes are observed following intermittent high-fluence monochromatic X-ray pulses, thus revealing the existence of a threshold response to X-FEL pulse intensity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Star Confusion Effect on SIM PlanetQuest Astrometric Performance

SIM PlanetQuest will measure star positions to an accuracy of a few microarcseconds using precise white light fringe measurements. One challenge for SIM observation scenario is "star confusion," where multiple stars are present in the instrument field of view. This is especially relevant for observing dim science targets because the density of number of stars increases rapidly with star magnitude. We study the effect of star confusion on the SIM astrometric performance due to systematic fringe errors caused by the extra photons from the confusion star(s}. Since star confusion from multiple stars may be analyzed as a linear superposition of the effect from single star confusion, we quantify the astrometric errors due to single star confusion surveying over many spectral types, including AOV, FOV, K5III, and MOV, and for various visual magnitude differences. To the leading order, the star confusion effect is characterized by the magnitude difference, spectral difference, and the angular separation between the target and confusion stars.Strategies for dealing with star confusion are presented. For example, since the presence of additional sources in the field of view leads to inconsistent delay estimates from different channels, with sufficient signal to noise ratio, the star confusion can be detected using chi-square statistics of fringe measurements from multiple spectral channels. An interesting result is that the star confusion can be detected even though the interferometer cannot resolve the separation between the target and confusion stars when their spectra are sufficiently different. Other strategies for mitigating the star confusion effect are also discussed.

crowded field↗

Methods, systems, and apparatuses for calculating global fluence for neutron and photon monte carlo transport using expected value estimators

Global fluence estimators may be calculated on accelerators and processors for neutron and photon Monte Carlo transport. Monte Carlo random walk simulation may be performed on the processors and the calculation of a Volumetric-Ray-Casting (VRC) estimator may be offloaded to the accelerators. The VRC estimator may modify an expected-value estimator to extend a pseudo-particle ray along the direction of the emitted particle from source and collision event through not only the event volume, but also through all volumes that describe the problem geometry. Additionally, many pseudo-particle rays may be sampled per event, rather than just a single pseudo-particle ray per event, in order to provide more complete angular coverage.

Sweezy, Jeremy Ed↗

Accuracy of the electron transport in mcnp5 and its suitability for ionization chamber response simulations: A comparison with the egsnrc and penelope codes

Purpose: In this work, accuracy of the mcnp5 code in the electron transport calculations and its suitability for ionization chamber (IC) response simulations in photon beams are studied in comparison to egsnrc and penelope codes. Methods: The electron transport is studied by comparing the depth dose distributions in a water phantom subdivided into thin layers using incident energies (0.05, 0.1, 1, and 10 MeV) for the broad parallel electron beams. The IC response simulations are studied in water phantom in three dosimetric gas materials (air, argon, and methane based tissue equivalent gas) for photon beams ({sup 60}Co source, 6 MV linear medical accelerator, and mono-energetic 2 MeV photon source). Two optional electron transport models of mcnp5 are evaluated: the ITS-based electron energy indexing (mcnp5{sub ITS}) and the new detailed electron energy-loss straggling logic (mcnp5{sub new}). The electron substep length (ESTEP parameter) dependency in mcnp5 is investigated as well. Results: For the electron beam studies, large discrepancies (>3%) are observed between the mcnp5 dose distributions and the reference codes at 1 MeV and lower energies. The discrepancy is especially notable for 0.1 and 0.05 MeV electron beams. The boundary crossing artifacts, which are well known for the mcnp5{sub ITS}, are observed for the mcnp5{sub new} only at 0.1 and 0.05 MeV beam energies. If the excessive boundary crossing is eliminated by using single scoring cells, the mcnp5{sub ITS} provides dose distributions that agree better with the reference codes than mcnp5{sub new}. The mcnp5 dose estimates for the gas cavity agree within 1% with the reference codes, if the mcnp5{sub ITS} is applied or electron substep length is set adequately for the gas in the cavity using the mcnp5{sub new}. The mcnp5{sub new} results are found highly dependent on the chosen electron substep length and might lead up to 15% underestimation of the absorbed dose. Conclusions: Since the mcnp5 electron transport calculations are not accurate at all energies and in every medium by general clinical standards, caution is needed, if mcnp5 is used with the current electron transport models for dosimetric applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

X-ray photonic microsystems for the manipulation of synchrotron light

In this study, photonic microsystems played an essential role in the development of integrated photonic devices, thanks to their unique spatiotemporal control and spectral shaping capabilities. Similar capabilities to markedly control and manipulate X-ray radiation are highly desirable but practically impossible due to the massive size of the silicon single-crystal optics currently used. Here we show that micromechanical systems can be used as X-ray optics to create and preserve the spatial, temporal and spectral correlation of the X-rays. We demonstrate that, as X-ray reflective optics they can maintain the wavefront properties with nearly 100% reflectivity, and as a dynamic diffractive optics they can generate nanosecond time windows with over 100-kHz repetition rates. Since X-ray photonic microsystems can be easily incorporated into lab-based and next-generation synchrotron X-ray sources, they bring unprecedented design flexibility for future dynamic and miniature X-ray optics for focusing, wavefront manipulation, multicolour dispersion, and pulse slicing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spectroscopy of the three-photon laser excitation of cold Rubidium Rydberg atoms in a magneto-optical trap

The spectra of the three-photon laser excitation 5S{sub 1/2} {yields} 5P{sub 3/2} {yields} 6S{sub 1/2}nP of cold Rb Rydberg atoms in an operating magneto-optical trap based on continuous single-frequency lasers at each stage are studied. These spectra contain two partly overlapping peaks of different amplitudes, which correspond to coherent three-photon excitation and incoherent three-step excitation due to the presence of two different ways of excitation through the dressed states of intermediate levels. A four-level theoretical model based on optical Bloch equations is developed to analyze these spectra. Good agreement between the experimental and calculated data is achieved by introducing additional decay of optical coherence induced by a finite laser line width and other broadening sources (stray electromagnetic fields, residual Doppler broadening, interatomic interactions) into the model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

APS-U LATTICE DESIGN FOR OFF-AXIS ACCUMULATION

A 67-pm hybrid-seven-bend achromat (H7BA) lattice is being proposed for a future Advanced Photon Source (APS) multi-bend-achromat (MBA) upgrade project. This lattice design pushes for smaller emittance and requires use of a swap-out (on-axis) injection scheme due to limited dynamic acceptance. Alternate lattice design work has also been performed for the APS upgrade to achieve better beam dynamics performance than the nominal APS MBA lattice, in order to allow off-axis accumulation. Two such alternate H7BA lattice designs, which target a still-low emittance of 90 pm, are discussed in detail in this paper. Although the single-particle-dynamics performance is good, simulations of collective effects indicate that surprising difficulty would be expected accumulating high single-bunch charge in this lattice. The brightness of the 90-pm lattice is also a factor of two lower than the 67-pm H7BA lattice.

APS-U↗

New Insertion Device Control System for the APS Upgrade

New Hybrid Permanent Magnet Undulators (HPMUs) have been designed and manufactured using servo motors for precise and reliable gap motion control for the Advanced Photon Source Upgrade (APS-U) project. Meanwhile, existing HPMUs equipped with legacy stepper motors are systematically replaced with servo motors. In parallel with mechanical modifications of the undulators, a comprehensive upgrade has been implemented for the control of the devices. This upgrade includes integration of standardized industrial components for replacement of motor controllers and motor drives using the Kollmorgen Programmable Controller Multi-axis Master (PCMM) controllers and the AKD2G series servo drives. Soft Input Output Controllers (IOCs) are developed and deployed to replace the legacy VME-based IOCs for both single-period undulators and Revolver undulators. In this paper, we will present the architecture of the new insertion device control system, including control mechanisms, interlock protocols, and tools for diagnostics and troubleshooting.

Li, W.↗

A balloon-borne Ge/Li/ spectrometer for gamma-ray astronomy

On June 10, 1974, a new high-resolution gamma ray spectrometer operating in the energy range of 0.05 to 10 MeV was successfully balloon-flight tested. This system uses four 40 cu cm Ge(Li) crystals in a single cryostat as prime sensors. A 6.35 cm thick CsI (Na) shield provides background rejection and collimation, defining a solid angle of 0.095 sr. Cooling is provided by a liquid-nitrogen dewar. The system was highly stable with spectral resolution of better than 2.5 keV at 1 MeV for the flight duration. The background total count rate was about 20 counts/sec. Numerous lines were observed, most of which originated from secondary neutron interactions in the spectrometer. The sensitivity of the system to line emissions originating in cosmic point sources is 0.0001 to 0.001 photons per sq cm s over the energy range.

Jacobson, A. S.↗

Sub-nanosecond laser-induced structural changes in the phase change material Ge2Sb2Te5 measured by an optical pump/x-ray probe technique

Phase-change alloys are characterized by reversible switching between amorphous and crystalline phases either by laser irradiation or by an electric programming current; the resulting changes in material properties can be used for non-volatile data storage. Switching typically occurs on nanosecond or less time scales. Considering the conflicting requirements for high-speed switching, yet long term data storage integrity, a deeper understanding of the switching processes in these materials is essential for insightful application development. Although, high-speed optical pump/probe observations have been made of reflectivity changes during the Ge{sub 2}Sb{sub 2}Te{sub 5} switching process, due to the nanosecond order time scales involved little is known about the corresponding changes in structure. In addition as the amorphous phase does not diffract, its structural analysis is not amenable to analysis by high-speed diffraction techniques. We have used synchrotron-based time-resolved x-ray absorption fine structure spectroscopy (XAFS), a technique equally suitable for amorphous and crystalline phases to elaborate details in structural changes in the phase-change process. We report on two experiments using high-speed pulsed lasers that serve as optical pumps to induced material changes followed by synchrotron produced x-ray burst that serve as a time resolved structural probe. The first experiment carried out at the Advanced Photon source focuses on changes due to heating in the amorphous phase. Our experimental results indicate that the maximum temperature reached during the re-amorphization process are less than the melting point indicated in the bulk phase diagram of Ge{sub 2}Sb{sub 2}Te{sub 5} reaching a maximum temperature of 620 C and in addition, do not share the same bond length distribution of a true melt. These findings strongly suggest the possibility of non-thermal melting. In the second experiment, we have obtained near-edge x-ray absorption data for a Ge{sub 2}Sb{sub 2}Te{sub 5} film in the process of transforming from the crystalline to the amorphous phase. This was accomplished by use of a second re-crystallizing laser in addition to the amorphous state induced fast pulsed laser. In the experiment presented here a 500 ps, 532 nm high-power pump laser was focused to a spot size of 20 {micro}m via the silica substrate onto a 50 {micro}m thick Ge{sub 2}Sb{sub 2}Te{sub 5} layer with a power density of approximately 60 mJ/cm{sup 2}; the layer was capped to prevent oxidation by air. Concentric to the laser beam, a 1 x 2.5 {micro}m x-ray pulse generated from a single electron bunch in the storage ring at Spring-8 was directed to the front side side of the sample. The relative delay of the laser with respect to the x-ray pulse was varied in steps of 500 ps in the current experiment. The presence of a 30 nm thick (ZnS){sub 0.85}(SiO{sub 2}){sub 0.15} layer above the Ge{sub 2}Sb{sub 2}Te{sub 5} layer caused the Ge{sub 2}Sb{sub 2}Te{sub 5} located below the layer spot to transform from a crystalline starting phase to an amorphous high-temperature phase and then back to a crystalline phase due to the trapped heat.

43 PARTICLE ACCELERATORS↗

THEORY OF DISPERSED FIXED-DELAY INTERFEROMETRY FOR RADIAL VELOCITY EXOPLANET SEARCHES

The dispersed fixed-delay interferometer (DFDI) represents a new instrument concept for high-precision radial velocity (RV) surveys for extrasolar planets. A combination of a Michelson interferometer and a medium-resolution spectrograph, it has the potential for performing multi-object surveys, where most previous RV techniques have been limited to observing only one target at a time. Because of the large sample of extrasolar planets needed to better understand planetary formation, evolution, and prevalence, this new technique represents a logical next step in instrumentation for RV extrasolar planet searches, and has been proven with the single-object Exoplanet Tracker (ET) at Kitt Peak National Observatory, and the multi-object W. M. Keck/MARVELS Exoplanet Tracker at Apache Point Observatory. The development of the ET instruments has necessitated fleshing out a detailed understanding of the physical principles of the DFDI technique. Here we summarize the fundamental theoretical material needed to understand the technique and provide an overview of the physics underlying the instrument's working. We also derive some useful analytical formulae that can be used to estimate the level of various sources of error generic to the technique, such as photon shot noise when using a fiducial reference spectrum, contamination by secondary spectra (e.g., crowded sources, spectroscopic binaries, or moonlight contamination), residual interferometer comb, and reference cross-talk error. Following this, we show that the use of a traditional gas absorption fiducial reference with a DFDI can incur significant systematic errors that must be taken into account at the precision levels required to detect extrasolar planets.

79 ASTRONOMY AND ASTROPHYSICS↗

Gravitational analog of the canonical acoustic black hole in Einstein-scalar-Gauss-Bonnet theory

In this work, in the context of modified gravity, a curved spacetime analogous to the 'canonical acoustic black hole (CABH)' is constructed. The source is a self-interacting scalar field which is non-minimally coupled to gravity through the Gauss–Bonnet invariant. The scalar-Gauss–Bonnet coupling function is characterized by three positive parameters: σ with units of (length), μ with units of (length)4, and a dimensionless parameter s, thus defining a three-parameter model for which the line element of CABH is a solution. The spacetime is equipped with spherical and static symmetry and has a single horizon determined in Schwarzschild coordinates by the region r = μ^(1/4). The solution admits a photon sphere at r = (3μ)^(1/4), and it is shown that in the region (3μ)^(1/4) ⩽ r < ∞ the scalar field satisfies the null, weak, and strong energy conditions. Nonetheless, the model with s = 1 has major physical relevance since for this case the scalar field is well defined in the entire region r ⩾ μ^(1/4), while for s ≠ 1 the scalar field blows up on the horizon.

Pedro Cañate↗

A GREEN'S FUNCTION APPROACH FOR DETERMINING DOSE RATES FOR SMALL GRAM QUANTITIES IN SHIPPING PACKAGINGS

The Small Gram Quantity (SGQ) concept is based on the understanding that small amounts of hazardous materials, in this case radioactive materials (RAM), are significantly less hazardous than large amounts of the same materials. This paper describes a methodology designed to estimate an SGQ for several neutron and gamma emitting isotopes that can be shipped in a package in compliance with 10 CFR Part 71 external radiation level limits regulations. The neutron and photon sources were calculated using both ORIGEN-S and RASTA. The response from a unit source in each neutron and photon group was calculated using MCNP5 with each unshielded and shielded container configuration. Effects of self-shielding on both neutron and photon response were evaluated by including either plutonium oxide or iron in the source region for the case with no shielded container. For the cases of actinides mixed with light elements, beryllium is the bounding light element. The added beryllium (10 to 90 percent of the actinide mass) in the cases studied represents between 9 and 47 percent concentration of the total mixture mass. For beryllium concentrations larger than 50 percent, the increase in the neutron source term and dose rate tend to increase at a much lower rate than at concentrations lower than 50%. The intimately mixed actinide-beryllium form used in these models is very conservative and thus the limits presented in this report are practical bounds on the mass that can be safely shipped. The calculated dose rate from one gram of each isotope was then used to determin the maximum amount of a single isotope that could be shipped in the Model 9977 Package (or packagings having the same or larger external dimensions as well as similar structural materials) and have the external radiation level within the regulatory dose limits at the surface of the package. The estimates of the mass limits presented would also serve as conservative limits for both the Models 9975 and 9978 packages. If a package contains a mixture of isotopes, the acceptability for shipment can be determined by a sum of fractions approach. It should be noted that the SGQ masses presented in this report represent limits that would comply with the external radiation limits under 10CFR Part 71. They do not necessarily bound lower limits that may be required to comply with other factors such as heat load of the package.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗