Search NASA⌕ Search

SEARCH · Search NASA

Results for “software estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Bay Area Regional Energy: Network Integrated Commercial Retrofits (BRICR) Project. Final Report

The BRICR project applied large-scale building energy modeling concepts with the aim of reducing the cost of energy efficiency targeting, design, and project development, and measurement of energy savings for energy efficiency programs implemented by local governments that serve small and medium commercial buildings (SMB). The project leveraged the services and resources of existing local government energy programs serving disadvantaged and hard-to-reach SMB customers. In contrast to programs run by utilities, local government programs generally do not have direct access to energy billing records for an entire class of customers in a geographic area, which prior research demonstrated useful for large-scale building energy model baseline development and calibration. , However, local governments are rich in public records that offer important clues about physical attributes and uses that, along with behavior, determine energy use. Relying only on public records, BRICR demonstrated development of credible baseline energy models for 3,792 office, retail, and hotel buildings. Publicly disclosed annual energy use data from a local energy benchmarking program and anonymized data from the Building Performance Database, the nation’s largest dataset about energy-related characteristics of buildings, were utilized to validate and calibrate energy models via an innovative method comparing distributions of energy intensity by fuel type for portfolios of buildings of similar size, vintage, and use. Portfolio calibration does not provide certainty that an energy model fits an individual building; the method is useful when billing data is not accessible – a common situation for researchers, energy service providers and ESCOs, local governments, and any party other than a utility. A software component was developed, the BRICR gem, which automates simulation when relevant data is added or edited by the user to a file saved in the standardized BuildingSync XML schema for energy audit data. The component was demonstrated as a simplified means to generate a mass of energy models corresponding to public records containing basic attributes such as building scale, location, use, year built, and aspect ratio in combination with building energy code prototype data corresponding to use and vintage. The component was also demonstrated as a simplified means to automate energy simulation when attributes are revised; the intention was to enable iterative improvement of the baseline model and energy savings estimates for common energy conservation measures as users revise relevant attributes based on their observations. In the context of institutional change and uncertainty for the participating local government energy programs, 13 whole building retrofits were completed. Impacts were measured by applying the CalTRACK2.0 methods to standardize measurement of normalized metered energy consumption. The GRIDMeter methods of stratified sampling and individual load shape analysis were applied to adjust for impacts of the effect of COVID-19 on retrofitted buildings in the context of all local buildings of similar size and use. Excluding impacts of the pandemic, retrofitted buildings demonstrated between 1.6% and 25.1% reduction in energy use. The project contributed use cases and feedback that helped inform evolution of the software tools and data formats that were combined for the first time in the BRICR project.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Data-driven Alignment of the Tracker for the Mu2e Experiment

An alignment of the Mu2e Tracker is investigated using the Mu2e Offline Software and Millepede-II. Simulated misalignments of Tracker planes were inserted between Monte-Carlo event generation and before reconstruction using randomly generated $(x,y,z)$-translations and rotations of the rigid-body planes in the detector model. Cosmic ray muons, with no magnetic field present in the Detector Solenoid, will follow a straight-line trajectory. A maximum-likelihood fit is used to reconstruct a track and determine its parameters. Tracks traversing at least four planes, with ten registered straw hits, and a maximum time residual of $20$ ns are selected to be used in an alignment sample. The cuts were chosen to discard tracks with low information content, such as those with high levels of multiple scattering or those with low numbers of measurements contributing to a single track fit. Millepede-II produces the resulting alignment constants according to a simultaneous least-squares fit of the alignment parameters and the track parameters for all input tracks. The improved alignment constants are used to repeat the process and recover an increased number of suitable tracks, further improving the estimate of the alignment constants in subsequent iterations. A performance study of the process was conducted on a misaligned Tracker in the case of translation-only, and translation plus rotational misalignments. In both cases, the correct alignment constants were recovered to within statistical error after three global fit iterations. Additionally, a continuous integration system was developed for the \texttt{Mu2e/Offline} GitHub repository, introducing a convenient automated testing process for all proposed changes (``pull requests"). The tests developed included a full build of the software, followed by tests of the validation routines, geometry overlap checking, and multi-threading mode. Additionally, code quality checks and low-statistics physics comparison checks a re also available.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance simulation of the soft gamma-ray concentrator

The soft gamma-ray concentrator is a telescope mission concept utilizing a suitable arrangement of bent multilayer structures of alternating low- and high-density materials. This lens is able to channel gamma-ray photons via total external reflection and concentrate the incident radiation to a point. The channeling technique offers the potential for concentrating gamma rays with focal lengths <10 m and energies >100 keV, beyond the reach of current grazing-incidence hard x-ray mirrors. For the performance estimation of such an instrument, we have developed a flexible set of computer modeling tools to compute the optical properties of multilayer structures, predict the channeling efficiency for a given multilayer configuration, and aid in the optimization of potential gamma-ray concentrator-based telescope designs. This modeling includes the multilayer optical properties calculated by the IMD software, the ray tracing using an IDL code, and the focal plane detector simulation by MEGAlib. We illustrate the potential of this approach by presenting simulated astronomical observations from a balloon-borne platform. The final result, including simulated effective area, instrument sensitivity, and polarization performance, shows that the gamma-ray concentrator will provide greatly increased sensitivity for next-generation soft gamma-ray missions with modest cost and complexity.

47 OTHER INSTRUMENTATION↗

Library based x-ray scatter correction for dedicated cone beam breast CT

Purpose: The image quality of dedicated cone beam breast CT (CBBCT) is limited by substantial scatter contamination, resulting in cupping artifacts and contrast-loss in reconstructed images. Such effects obscure the visibility of soft-tissue lesions and calcifications, which hinders breast cancer detection and diagnosis. In this work, we propose a library-based software approach to suppress scatter on CBBCT images with high efficiency, accuracy, and reliability. Methods: The authors precompute a scatter library on simplified breast models with different sizes using the GEANT4-based Monte Carlo (MC) toolkit. The breast is approximated as a semiellipsoid with homogeneous glandular/adipose tissue mixture. For scatter correction on real clinical data, the authors estimate the breast size from a first-pass breast CT reconstruction and then select the corresponding scatter distribution from the library. The selected scatter distribution from simplified breast models is spatially translated to match the projection data from the clinical scan and is subtracted from the measured projection for effective scatter correction. The method performance was evaluated using 15 sets of patient data, with a wide range of breast sizes representing about 95% of general population. Spatial nonuniformity (SNU) and contrast to signal deviation ratio (CDR) were used as metrics for evaluation. Results: Since the time-consuming MC simulation for library generation is precomputed, the authors’ method efficiently corrects for scatter with minimal processing time. Furthermore, the authors find that a scatter library on a simple breast model with only one input parameter, i.e., the breast diameter, sufficiently guarantees improvements in SNU and CDR. For the 15 clinical datasets, the authors’ method reduces the average SNU from 7.14% to 2.47% in coronal views and from 10.14% to 3.02% in sagittal views. On average, the CDR is improved by a factor of 1.49 in coronal views and 2.12 in sagittal views. Conclusions: The library-based scatter correction does not require increase in radiation dose or hardware modifications, and it improves over the existing methods on implementation simplicity and computational efficiency. As demonstrated through patient studies, the authors’ approach is effective and stable, and is therefore clinically attractive for CBBCT imaging.

60 APPLIED LIFE SCIENCES↗

Confidence intervals with a priori parameter bounds

We review the methods of constructing confidence intervals that account for a priori information about one-sided constraints on the parameter being estimated. We show that the so-called method of sensitivity limit yields a correct solution of the problem. Derived are the solutions for the cases of a continuous distribution with non-negative estimated parameter and a discrete distribution, specifically a Poisson process with background. For both cases, the best upper limit is constructed that accounts for the a priori information. A table is provided with the confidence intervals for the parameter of Poisson distribution that correctly accounts for the information on the known value of the background along with the software for calculating the confidence intervals for any confidence levels and magnitudes of the background (the software is freely available for download via Internet).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Python Robust Phase Estimation (PyRPE)

Robust Phase Estimation (RPE) is a quantum algorithm to determine the relative phases of eigenstates of a unitary operator. This code implements the classical portion of the RPE algorithm, useful both in simulation (e.g., Sandia's pyGSTi or IBM's Qiskit simulators) and on actual quantum hardware (e.g., IBM's Qiskit Quantum Experience). It additionally implements improvements in these dependent software packages, for both required core function of the RPE and improved usability. SAND2020-12547 M Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-NA0003525.

Russo, Antonio↗

Using Whisper-1.1 to Guide Improvements to Nuclear Data Evaluations

Along with the latest release of the general purpose Monte Carlo radiation transport code, MCNP6.2, came the first officially released version of Whisper, version 1.1, a statistical analysis code used for nuclear criticality safety (NCS) validation. The Whisper software package is primarily used to calculate the upper subcritical limit (USL) of a particular application case along with components of the margin of subcriticality (MOS). In the calculation of the MOS due to nuclear data uncertainties, Whisper uses the generalized linear-least-squares (GLLS) approach to obtain adjusted nuclear data uncertainties which are then propagated to estimate the nuclear data uncertainties in the k eff of the application. Due to the fact that Whisper contains the simulated and measured k eff values for over 1100 benchmarks, nuclear data sensitivity profiles for each benchmark along with the nuclear data covariance matrices, all of which are used in the GLLS method, it is possible to easily utilize these data available to help guide improvements to nuclear data evaluations. In the present work, the Whisper data and the GLLS method are used together to suggest an adjusted nuclear data cross section evaluation specifically for 233 U such that the agreement between the calculated and experimental k eff measurements of the relevant benchmarks are improved. With this adjusted nuclear data available, feedback to the theoretical and experimental nuclear data community is provided.

97 MATHEMATICS AND COMPUTING↗

Quantum Accelerators for High-performance Computing Systems

We define some of the programming and system-level challenges facing the application of quantum processing to high-performance computing. Alongside barriers to physical integration, prominent differences in the execution of quantum and conventional programs challenges the intersection of these computational models. Following a brief overview of the state of the art, we discuss recent advances in programming and execution models for hybrid quantum-classical computing. We discuss a novel quantum-accelerator framework that uses specialized kernels to offload select workloads while integrating with existing computing infrastructure. We elaborate on the role of the host operating system to manage these unique accelerator resources, the prospects for deploying quantum modules, and the requirements placed on the language hierarchy connecting these different system components. We draw on recent advances in the modeling and simulation of quantum computing systems with the development of architectures for hybrid high-performance computing systems and the realization of software stacks for controlling quantum devices. Finally, we present simulation results that describe the expected system-level behavior of high-performance computing systems composed from compute nodes with quantum processing units. We describe performance for these hybrid systems in terms of time-to-solution, accuracy, and energy consumption, and we use simple application examples to estimate the performance advantage of quantum acceleration.

Humble, Travis↗

Using Whisper-1.1 to guide improvements to nuclear data evaluations

Along with the latest release of the general purpose Monte Carlo radiation transport code, MCNP6.2, came the first officially released version of Whisper, version 1.1, a statistical analysis code used for nuclear criticality safety (NCS) validation. The Whisper software package is primarily used to calculate the upper subcritical limit (USL) of a particular application case along with components of the margin of subcriticality (MOS). In the calculation of the MOS due to nuclear data uncertainties, Whisper uses the generalized linear-least-squares (GLLS) approach to obtain adjusted nuclear data uncertainties which are then propagated to estimate the nuclear data uncertainties in the k{sub eff} of the application. Due to the fact that Whisper contains the simulated and measured k{sub eff} values for over 1100 benchmarks, nuclear data sensitivity profiles for each benchmark along with the nuclear data covariance matrices, all of which are used in the GLLS method, it is possible to easily utilize these data available to help guide improvements to nuclear data evaluations. In the present work, the Whisper data and the GLLS method are used together to suggest an adjusted nuclear data cross section evaluation specifically for {sup 233}U such that the agreement between the calculated and experimental k{sub eff} measurements of the relevant benchmarks are improved. With this adjusted nuclear data available, feedback to the theoretical and experimental nuclear data community is provided. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Field testing and validation of a low-cost MPC for demand flexibility for grid-interactive K-12 schools

K-12 school buildings account for the highest energy consumption within the public sector. Implementing advanced HVAC controls in grid-interactive K-12 schools could bring substantial economic advantages and grid flexibility. Our previous study demonstrated that a low-cost model predictive control (MPC) solution, which coordinates multiple packaged units, can enable demand flexibility without major hardware upgrades. However, a significant gap remains between academic pilots and market-ready scalable solutions. This paper extends the previous single-site pilot to a multi-site demonstration involving three school campuses (95 total units) through a commercial technology transfer process. Addressing the challenge of verifying performance with sparse field data, we present a new statistical approach using Bayesian methods to estimate the MPC’s effect on peak demand. Unlike traditional methods, this approach robustly quantifies uncertainty in non-normal, limited datasets. The results confirm the solution’s replicability, achieving a 21.6–38.9% reduction in HVAC peak demand (10.8–22.1% at the site-level) with > 98% probability across diverse locations. Finally, we document critical barriers to scaling software-as-a-service (SaaS) solutions–such as API instability and diverse legacy systems–and offer practical strategies to accelerate the commercial adoption of grid-interactive efficient buildings.

Ham, Sang Woo↗

Interfraction rotation of the prostate as evaluated by kilovoltage X-ray fiducial marker imaging in intensity-modulated radiotherapy of localized prostate cancer

To quantify the daily rotation of the prostate during a radiotherapy course using stereoscopic kilovoltage (kV) x-ray imaging and intraprostatic fiducials for localization and positioning correction. From 2005 to 2009, radio-opaque fiducial markers were inserted into 38 patients via perineum into the prostate. The ExacTrac/Novalis Body X-ray 6-day image acquisition system (ET/NB; BrainLab AG, Feldkirchen, Germany) was used to determine and correct the target position. During the first period in 10 patients we recorded all rotation errors but used only Y (table) for correction. For the next 28 patients we used for correction all rotational coordinates, i.e., in addition Z (superior-inferior [SI] or roll) and X (left-right [LR] or tilt/pitch) according to the fiducial marker position by use of the Robotic Tilt Module and Varian Exact Couch. Rotation correction was applied above a threshold of 1 Degree-Sign displacement. The systematic and random errors were specified. Overall, 993 software-assisted rotational corrections were performed. The interfraction rotation errors of the prostate as assessed from the radiodense surrogate markers around the three axes Y, Z, and X were on average 0.09, -0.52, and -0.01 Degree-Sign with standard deviations of 2.01, 2.30, and 3.95 Degree-Sign , respectively. The systematic uncertainty per patient for prostate rotation was estimated with 2.30, 1.56, and 4.13 Degree-Sign and the mean random components with 1.81, 2.02, and 3.09 Degree-Sign . The largest rotational errors occurred around the X-axis (pitch), but without preferring a certain orientation. Although the error around Z (roll) can be compensated on average by a transformation with 4 coordinates, a significant error around X remains and advocates the full correction with 6 coordinates. Rotational errors as assessed via daily stereoscopic online imaging are significant and dominate around X. Rotation possibly degrades the dosimetric coverage of the target volume and may require suitable strategies for correction.

61 RADIATION PROTECTION AND DOSIMETRY↗

Tumor control probability and the utility of 4D vs 3D dose calculations for stereotactic body radiotherapy for lung cancer

Four-dimensional (4D) dose calculations for lung cancer radiotherapy have been technically feasible for a number of years but have not become standard clinical practice. The purpose of this study was to determine if clinically significant differences in tumor control probability (TCP) exist between 3D and 4D dose calculations so as to inform the decision whether 4D dose calculations should be used routinely for treatment planning. Radiotherapy plans for Stage I-II lung cancer were created for 8 patients. Clinically acceptable treatment plans were created with dose calculated on the end-exhale 4D computed tomography (CT) phase using a Monte Carlo algorithm. Dose was then projected onto the remaining 9 phases of 4D-CT using the Monte Carlo algorithm and accumulated onto the end-exhale phase using commercially available deformable registration software. The resulting dose-volume histograms (DVH) of the gross tumor volume (GTV), planning tumor volume (PTV), and PTV{sub setup} were compared according to target coverage and dose. The PTV{sub setup} was defined as a volume including the GTV and a margin for setup uncertainties but not for respiratory motion. TCPs resulting from these DVHs were estimated using a wide range of alphas, betas, and tumor cell densities. Differences of up to 5 Gy were observed between 3D and 4D calculations for a PTV with highly irregular shape. When the TCP was calculated using the resulting DVHs for fractionation schedules typically used in stereotactic body radiation therapy (SBRT), the TCP differed at most by 5% between 4D and 3D cases, and in most cases, it was by less than 1%. We conclude that 4D dose calculations are not necessary for most cases treated with SBRT, but they might be valuable for irregularly shaped target volumes. If 4D calculations are used, 4D DVHs should be evaluated on volumes that include margin for setup uncertainty but not respiratory motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Solid waste bin detection and classification using Dynamic Time Warping and MLP classifier

Highlights: • Solid waste bin level detection using Dynamic Time Warping (DTW). • Gabor wavelet filter is used to extract the solid waste image features. • Multi-Layer Perceptron classifier network is used for bin image classification. • The classification performance evaluated by ROC curve analysis. - Abstract: The increasing requirement for Solid Waste Management (SWM) has become a significant challenge for municipal authorities. A number of integrated systems and methods have introduced to overcome this challenge. Many researchers have aimed to develop an ideal SWM system, including approaches involving software-based routing, Geographic Information Systems (GIS), Radio-frequency Identification (RFID), or sensor intelligent bins. Image processing solutions for the Solid Waste (SW) collection have also been developed; however, during capturing the bin image, it is challenging to position the camera for getting a bin area centralized image. As yet, there is no ideal system which can correctly estimate the amount of SW. This paper briefly discusses an efficient image processing solution to overcome these problems. Dynamic Time Warping (DTW) was used for detecting and cropping the bin area and Gabor wavelet (GW) was introduced for feature extraction of the waste bin image. Image features were used to train the classifier. A Multi-Layer Perceptron (MLP) classifier was used to classify the waste bin level and estimate the amount of waste inside the bin. The area under the Receiver Operating Characteristic (ROC) curves was used to statistically evaluate classifier performance. The results of this developed system are comparable to previous image processing based system. The system demonstration using DTW with GW for feature extraction and an MLP classifier led to promising results with respect to the accuracy of waste level estimation (98.50%). The application can be used to optimize the routing of waste collection based on the estimated bin level.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Generating data ensembles over a model grid from sparse climate measurements.

Parameterizations in high-end climate models can be evaluated with observed climate and meteorological data. Often this evaluation is achieved by averaging measured quantities over time and space to match the spatial and temporal resolution of a gridded climate model without any regard for the statistical errors in doing so. We present a statistical method to interpolate sparsely located surface measurements into a uniform spatial grid representative of global and regional models of the atmosphere and climate. This method provides estimates of mean values over the entire domain containing the measurement sites as well as the uncertainty in the estimated quantities at the grid locations through multiple simulations to create 'data ensembles.' We demonstrate this method using measurements of surface sensible heat flux over the southern Great Plains region gathered through the Department of Energy's Atmospheric Radiation Measurement (ARM) program. Application to the numerous other climate variables measured through the ARM program and the development of a software tool to streamline data management and implementation of the statistical models is also discussed.

54 ENVIRONMENTAL SCIENCES↗

SU-E-T-318: Dosimetric Evaluation of ArcCHECK and 3DVH System Using Customized Polymer Gel Dosimeter

Purpose: ArcCHECK and 3DVH system (Sun Nuclear) can reconstruct the three-dimensional (3D) dose distribution and provide the DVH analysis in a patient. The aim of this study was to evaluate dosimetric accuracy of this system using customized polymer gel dosimeter, and also Gafchromic EBT3 films. Methods: Polyacrylamide-based gel contained magnesium chloride as a sensitizer (iPAGAT) was used in this study. Volumetric-modulated arc therapy (VMAT) plan was performed for the C-shape structure by the Eclipse treatment planning system (Varian) and used to irradiate the ArcCHECK by the Novalis Tx linear accelerator (Varian/BrainLAB). The cubic phantom filled with iPAGAT and EBT3 films placed in three orthogonal planes (axial, sagittal, and coronal) inserted into the I’mRT Phantom (IBA Dosimetry) simulated a patient were irradiated with the same VMAT plan. The measurement-guided 3D dose distribution was reconstructed using 3DVH software from the measured data of the ArcCHECK. The 3D dose distribution in iPAGAT was read out by Signa 1.5 T MRI system (GE), and 2D dose distribution on EBT3 was read out by color scanner (Epson). The comparison of all the dose distributions was performed with dose profiles and gamma index analysis in orthogonal planes using in-house developed software. Results: A good agreement was observed by overlaying the dose profiles of 3DVH, EBT3, and iPAGAT. The mean pass rates by gamma index analysis with 3%/3 mm criteria in orthogonal planes were 94.3% (3DVH vs EBT3), 91.1% (3DVH vs iPAGAT), and 96.4% (iPAGAT vs EBT3), respectively. Conclusion: 3D dose distribution reconstructed by ArcCHECK and 3DVH system was estimated accurately in a patient. However, slightly differences were observed between 3DVH and iPAGAT because of MRI noise, therefore further study is required to improve the accuracy of MRI based polymer gel dosimetry for the DVH analysis.

60 APPLIED LIFE SCIENCES↗

Code for BALDR Study 07.04

SAND2024-11256O The Code for BALDR Study 07.04 software reproduces results from the BALDR study concerning "Multilabel Proportion Prediction and Out-of-Distribution Detection on Gamma Spectra of Short-Lived Fission Products." This code can reproduce a scientific study following the step numbers present in the file names. The scientific study uses synthetic and measured data to find the best model for the radioisotope proportion estimation task of interest and generates results. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Morrow, Tyler↗

LANL Lightning Flash Time Duration Ground Truth

Video cameras were used to record cloud-to-ground (CG) lightning flash events on or near Los Alamos National Laboratory (LANL) over 3 days in August, 2018. Custom scripting software was created to automatically trigger camera recording off National Lightning Data Network (NLDN) streamed reporting of CG lightning within 12 miles of LANL. Cameras were sited near meteorology towers at LANL and 4k video captures were manually reviewed to extract still sequence images from 9 identified CG flashes. A camera frame rate of 30 fps was used to estimate time durations of 33-200 milliseconds over this natural lightning dataset.

58 GEOSCIENCES↗

Optimal Distribution System Voltage Regulation using State Estimation and DER Grid-Support Functions

Increasing solar energy penetrations may create challenges for distribution system operations because production variability can lead to large voltage deviations or protection system miscoordination. Instituting advanced management systems on distribution systems is one promising method for combating these challenges by intelligently controlling distribution assets to regulate voltage and ensure protection safety margins. While it is generally not the case today, greater deployment of power system sensors and interoperable distributed energy resources (DER)e.g., photovoltaic (PV) inverters, energy storage systems (ESS), electric vehicles (EVs)will enable situational awareness, control, and optimization of distribution systems. In this work, a control system was created which measures power system parameters to estimate the status of a feeder, forecasts the distribution state over a short-term horizon, and issues optimal set point commands to distribution-connected equipment to regulate voltage and protect the system. This two-year project integrated multiple research innovations into a management system designed to safely allow PV penetrations of 50% or greater. The integrated software was demonstrated through extensive real-time (RT) and power hardware-in-the-loop studies and a field demonstration on a live power system with a 684 kVA PV system.

24 POWER TRANSMISSION AND DISTRIBUTION↗