Search NASA⌕ Search

SEARCH · Search NASA

Results for “source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Analysis of 3-panel and 4-panel microscale ionization sources

Two designs of a microscale electron ionization (EI) source are analyzed herein: a 3-panel design and a 4-panel design. Devices were fabricated using microelectromechanical systems technology. Field emission from carbon nanotube provided the electrons for the EI source. Ion currents were measured for helium, nitrogen, and xenon at pressures ranging from 10{sup -4} to 0.1 Torr. A comparison of the performance of both designs is presented. The 4-panel microion source showed a 10x improvement in performance compared to the 3-panel device. An analysis of the various factors affecting the performance of the microion sources is also presented. SIMION, an electron and ion optics software, was coupled with experimental measurements to analyze the ion current results. The electron current contributing to ionization and the ion collection efficiency are believed to be the primary factors responsible for the higher efficiency of the 4-panel microion source. Other improvements in device design that could lead to higher ion source efficiency in the future are also discussed. These microscale ion sources are expected to find application as stand alone ion sources as well as in miniature mass spectrometers.

07 ISOTOPE AND RADIATION SOURCES↗

Fluid model of the sheath in front of a floating electrode immersed in a magnetized plasma with oblique magnetic field: Some comments on ion source terms and ion temperature effects

A one-dimensional fluid model of the magnetized plasma-wall transition region in front of a floating electrode immersed in a magnetized plasma with oblique magnetic field is presented. The Boltzmann relation is assumed for the electrons, while the positive ions obey the ion continuity and momentum exchange equation. The ions are assumed to be isothermal. By comparison with a two-fluid model, it is shown that assuming the Boltzmann relation for the electrons implies that there is no creation or annihilation of the electrons. Consequently, there should not be any creation and annihilation of the positive ions either. The models that assume the Boltzmann relation for the electrons and a non-zero ion source term at the same time are therefore inconsistent, but such models have nevertheless been used extensively by many authors. So, in this work, an extensive comparison of the results obtained using the zero source term on one hand and three different non-zero source terms on the other hand is made. Four different ion source terms are considered in total: the zero source term and three different non-zero ion source terms. When the zero source term is used, the model becomes very sensitive to the boundary conditions, and in some cases, the solutions exhibit large amplitude oscillations. If any of the three non-zero ion source terms is used, those problems are eliminated, but also the consistency of the model is broken. The model equations are solved numerically in the entire magnetized plasma-wall transition region. For zero ion temperature, the model can be solved even if a very small ion velocity is selected as a boundary condition. For finite ion temperature, the system of equations becomes stiff, unless the ion velocity at the boundary is increased slightly above the ion thermal velocity. A simple method how to find a solution with a very small ion velocity at the boundary also for finite ion temperature in the entire magnetized plasma-wall transition region is proposed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Assessment on security system of radioactive sources used in hospitals of Thailand

Unsecured radioactive sources have caused deaths and serious injuries in many parts of the world. In Thailand, there are 17 hospitals that use teletherapy with cobalt-60 radioactive sources. They need to be secured in order to prevent unauthorized removal, sabotage and terrorists from using such materials in a radiological weapon. The security system of radioactive sources in Thailand is regulated by the Office of Atoms for Peace in compliance with Global Threat Reduction Initiative (GTRI), U.S. DOE, which has started to be implemented since 2010. This study aims to perform an assessment on the security system of radioactive sources used in hospitals in Thailand and the results can be used as a recommended baseline data for development or improvement of hospitals on the security system of a radioactive source at a national regulatory level and policy level. Results from questionnaires reveal that in 11 out of 17 hospitals (64.70%), there were a few differences in conditions of hospitals using radioactive sources with installation of the security system and those without installation of the security system. Also, personals working with radioactive sources did not clearly understand the nuclear security law. Thus, government organizations should be encouraged to arrange trainings on nuclear security to increase the level of understanding. In the future, it is recommended that the responsible government organization issues a minimum requirement of nuclear security for every medical facility using radioactive sources.

07 ISOTOPE AND RADIATION SOURCES↗

X-RAY SOURCES AND THEIR OPTICAL COUNTERPARTS IN THE GALACTIC GLOBULAR CLUSTER M12 (NGC 6218)

We study a Chandra X-ray Observatory ACIS-S observation of the Galactic globular cluster M12. With a 26 ks exposure time, we detect six X-ray sources inside the half-mass radius (2.'16) of which two are inside the core radius (0.'72) of the cluster. If we assume that these sources are all associated with globular cluster M12, the luminosity L {sub X} among these sources between 0.3 and 7.0 keV varies roughly from 10{sup 30} to 10{sup 32} erg s{sup -1}. For identification, we also analyzed the Hubble Space Telescope (HST) Advanced Camera for Surveys (ACS) and Wide Field and Planetary Camera 2 (WFPC2) data and identified the optical counterparts to five X-ray sources inside the HST ACS field of view. According to the X-ray and optical features, we found 2-5 candidate active binaries (ABs) or cataclysmic variables (CVs) and 0-3 background galaxies within the HST ACS field of view. Based on the assumption that the number of X-ray sources scales with the encounter rate and the mass of the globular cluster, we expect two X-ray sources inside M12, and the expectation is consistent with our observational results. Therefore, the existence of identified X-ray sources (possible CVs or ABs) in M12 suggests the primordial origin of X-ray sources in globular clusters which is in agreement with previous studies.

79 ASTRONOMY AND ASTROPHYSICS↗

CHANDRA AND HST STUDIES OF THE X-RAY SOURCES IN GALACTIC GLOBULAR CLUSTER M92

We present the analysis of two observations of M92 taken with the Chandra X-Ray Observatory. We combined the two data sets with a total exposure of {approx}52 ks. With the combined observation, we detected 10 X-ray sources inside the half-mass radius (1.'02), five of which are inside the core radius (0.'26) of M92. The luminosities of the 10 sources are roughly within the range of 10{sup 30}-10{sup 32} erg s{sup -1} assuming cluster memberships. The background estimation suggests 7-8 cluster members and 2-3 background galaxies in M92. We identified the 10 sources by using Hubble Space Telescope Advanced Camera for Surveys observations of M92. Based on the X-ray and optical characteristics, we classified 4-5 possible candidates for cataclysmic variables within the half-mass radius. We discussed the possible formation mechanisms of the X-ray sources in M92 by comparing the predicted X-ray source number and observational results. Under the assumption that the number of X-ray sources scales with the encounter rate and the mass of the globular cluster, we expected eight X-ray sources formed from dynamical interactions and four from primordial binaries inside M92, which is consistent with the background estimation and comparable with the observational results. We therefore suggest that the X-ray sources in M92 may be contributed from both dynamical origin and primordial binaries.

79 ASTRONOMY AND ASTROPHYSICS↗

XMM-NEWTON OBSERVATIONS OF THE TeV {gamma}-RAY SOURCE HESS J1804-216

We have analyzed three XMM-Newton observations of the central part of the unidentified TeV {gamma}-ray source HESS J1804-216. We focus on two X-ray sources, 2XMMi J180442.0-214221 (Src 1) and 2XMMi J180432.5-214009 (Src 2), which were suggested to be the possible X-ray counterparts to the TeV source. We discover a 2.93 hr X-ray periodicity from Src 1, with the pulse profile explained with a self-eclipsing pole in an eclipsing polar. Src 2 exhibits a strong Fe emission line (FWHM {approx} 0.3 keV and equivalent width {approx}0.8 keV) and large X-ray variability on timescales of hours and is probably an intermediate polar. Thus Src 1 and Src 2 are probably two field sources not responsible for the TeV emission. The observations were contaminated by strong stray light from a nearby bright source, and we see no clear extended X-ray emission that can be attributed to the supernova remnant G8.7-0.1, a popular possible association with the TeV source. The other possible association, the pulsar wind nebula candidate PSR J1803-2137, shows little long-term variability compared with a previous Chandra observation. Many point sources were serendipitously detected, but most of them are probably normal stars. Three new candidate compact object systems (other than Src 1, Src 2, and PSR J1803-2137) are also found. They are far away from the TeV source and are probably also magnetic cataclysmic variables, thus unlikely to be responsible for the TeV emission.

79 ASTRONOMY AND ASTROPHYSICS↗

Discovery of a highly variable dipping ultraluminous X-ray source in M94

We report the discovery of a new ultraluminous X-ray source (ULX) 2XMM J125048.6+410743 within the spiral galaxy M94. The source has been observed by ROSAT, Chandra, and XMM-Newton on several occasions, exhibiting as a highly variable persistent source or a recurrent transient with a flux variation factor of ≳100, a high duty cycle (at least ∼70%), and a peak luminosity of L {sub X} ∼ 2 × 10{sup 39} erg s{sup –1} (0.2-10 keV, absorbed). In the brightest observation, the source is similar to typical low-luminosity ULXs, with the spectrum showing a high-energy cutoff but harder than that from a standard accretion disk. There are also sporadical short dips, accompanied by spectral softening. In a fainter observation with L {sub X} ∼ 3.6 × 10{sup 38} erg s{sup –1}, the source appears softer and is probably in the thermal state seen in Galactic black hole X-ray binaries (BHBs). In an even fainter observation (L {sub X} ∼ 9 × 10{sup 37} erg s{sup –1}), the spectrum is harder again, and the source might be in the steep-power-law state or the hard state of BHBs. In this observation, the light curve might exhibit ∼7 hr (quasi-)periodic large modulations over two cycles. The source also has a possible point-like optical counterpart from Hubble Space Telescope images. In terms of the colors and the luminosity, the counterpart is probably a G8 supergiant or a compact red globular cluster containing ∼2 × 10{sup 5} K dwarfs, with some possible weak UV excess that might be ascribed to accretion activity. Thus, our source is a candidate stellar-mass BHB with a supergiant companion or with a dwarf companion residing in a globular cluster. Our study supports that some low-luminosity ULXs are supercritically accreting stellar-mass BHBs.

79 ASTRONOMY AND ASTROPHYSICS↗

Recent H - ion source research and development at the Oak Ridge National Laboratory

The U.S. Spallation Neutron Source (SNS) is a state-of-the-art neutron scattering facility delivering the world's most intense pulsed neutron beams to a wide array of instruments which are used to conduct investigations in many fields of science and engineering. Neutrons are produced from spallation of liquid Hg by bombardment of short (~1 μs), intense (~35 A) pulses of protons delivered at 60 Hz by a storage ring which is fed by a high-intensity, ~1 GeV H - LINAC. This facility has operated almost continuously since 2006, with ion source performance increasing over those years, and currently providing 50–60 mA of H - ions with a duty-factor of 6% for maintenance-free runs of several months with near 100% availability. Ion source research and development at ORNL has played a key role in enabling and supporting this success: this report provides an update on some of the ongoing ion source research and development efforts which have been undertaken since the previous Negative Ion Beams and Sources (NIBS) conference in 2020. These include significant improvements to H - beam current by extraction from a larger source outlet aperture and improvements to the electron dumping system which should eliminate the gradual loss of electrode voltage over the course of a run which has occasionally impacted SNS operations. Improvement and simplification of the plasma ignition system for the external antenna ion source, a long-standing problem, was also realized. Lastly, RF coupling efficiency was measured for both the SNS internal and external antenna ion sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A theoretical study on phase-contrast mammography with Thomson-scattering x-ray sources

Purpose: The x-ray transmitted beam from any material/tissue depends on the complex refractive index (n=1-{delta}+i{beta}), where {delta} is responsible for the phase shift and {beta} is for the beam attenuation. Although for human tissues, the {delta} cross section is about 1000 times greater than the {beta} ones in the x-ray energy range from 10 to 150 keV, the gain in breast tumor visualization of phase-contrast mammography (PCM) with respect to absorption contact imaging (AI) is limited by the maximum dose that can be delivered to the patient. Moreover, in-line PC imaging (PCI) is the simplest experimental mode among all available x-ray PCI techniques since no optics are needed. The latter is a fundamental requirement in order to transfer the results of laboratory research into hospitals. Alternative to synchrotron radiation sources, the implementation of relativistic Thomson-scattering (TS) x-ray sources is particularly suitable for hospital use because of their high peak brightness within a relatively compact and affordable system. In this work, the possibility to realize PCM using a TS source in a hospital environment is studied, accounting for the effect of a finite deliverable dose on the PC visibility enhancement with respect to AI. Methods: The contrast-to-noise ratio of tumor-tissue lesions in PCM has been studied on the bases of a recent theoretical model, describing image contrast formation by means of both wave-optical theory and the mutual coherence formalism. The latter is used to describe the evolution, during wave propagation, of the coherence of the wave field emitted by a TS source. The contrast-to-noise ratio for both PCI and AI has been analyzed in terms of tumor size, beam energy, detector, and source distances, studying optimal conditions for performing PCM. Regarding other relevant factors which could influence ''tumor'' visibility, the authors have assumed simplified conditions such as a spherical shape description of the tumor inclusion, a constant surrounding background, ideal conditions for the calculus of the contrast-to-noise ratio. Results: The results show the possibility to enhance with PCI the signal-to-noise ratio for features in the submillimeter scale. This finding could give PCM a great advantage with respect to AI, opening the possibility to decrease the number of wrong diagnoses before histological exams. The results agree with experimental evidences obtained by Dreossi et al.[D. Dreossi et al., ''The mammography project at the SYRMEP beamline,'' Eur. J. Radiol. 68, S58-S62 (2008)] with real PCM using synchrotron radiation. Conclusions: The challenging characteristics of TS sources, suitable for PCM, should be fluxes of at least 10{sup 11} photons/s emitted by very small sources of about 10 {mu}m, together with moderate energy spreads (less than 10%) in order to realize both sufficient spatial coherence and enough fluence on the patient, collecting images in reasonable exposure times. These fluxes will be achieved by next generation TS sources which are already under development.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microfocus x-ray imaging of traceable pointlike {sup 22}Na sources for quality control

Purpose: The purpose of this study is to propose a microfocus x-ray imaging technique for observing the internal structure of small radioactive sources and evaluating geometrical errors quantitatively, and to apply this technique to traceable pointlike {sup 22}Na sources, which were designed for positron emission tomography calibration, for the purpose of quality control of the pointlike sources. Methods: A microfocus x-ray imaging system with a focus size of 0.001 mm was used to obtain projection x-ray images and x-ray CT images of five pointlike source samples, which were manufactured during 2009-2012. The obtained projection and tomographic images were used to observe the internal structure and evaluate geometrical errors quantitatively. Monte Carlo simulation was used to evaluate the effect of possible geometrical errors on the intensity and uniformity of 0.511 MeV annihilation photon pairs emitted from the sources. Results: Geometrical errors were evaluated with sufficient precision using projection x-ray images. CT images were used for observing the internal structure intuitively. As a result, four of the five examined samples were within the tolerance to maintain the total uncertainty below {+-}0.5%, given the source radioactivity; however, one sample was found to be defective. Conclusions: This quality control procedure is crucial and offers an important basis for using the pointlike {sup 22}Na source as a basic calibration tool. The microfocus x-ray imaging approach is a promising technique for visual and quantitative evaluation of the internal geometry of small radioactive sources.

07 ISOTOPE AND RADIATION SOURCES↗

Experimental validation of a kilovoltage x-ray source model for computing imaging dose

Purpose: To introduce and validate a kilovoltage (kV) x-ray source model and characterization method to compute absorbed dose accrued from kV x-rays. Methods: The authors propose a simplified virtual point source model and characterization method for a kV x-ray source. The source is modeled by: (1) characterizing the spatial spectral and fluence distributions of the photons at a plane at the isocenter, and (2) creating a virtual point source from which photons are generated to yield the derived spatial spectral and fluence distribution at isocenter of an imaging system. The spatial photon distribution is determined by in-air relative dose measurements along the transverse (x) and radial (y) directions. The spectrum is characterized using transverse axis half-value layer measurements and the nominal peak potential (kVp). This source modeling approach is used to characterize a Varian{sup ®} on-board-imager (OBI{sup ®}) for four default cone-beam CT beam qualities: beams using a half bowtie filter (HBT) with 110 and 125 kVp, and a full bowtie filter (FBT) with 100 and 125 kVp. The source model and characterization method was validated by comparing dose computed by the authors’ inhouse software (kVDoseCalc) to relative dose measurements in a homogeneous and a heterogeneous block phantom comprised of tissue, bone, and lung-equivalent materials. Results: The characterized beam qualities and spatial photon distributions are comparable to reported values in the literature. Agreement between computed and measured percent depth-dose curves is ⩽2% in the homogeneous block phantom and ⩽2.5% in the heterogeneous block phantom. Transverse axis profiles taken at depths of 2 and 6 cm in the homogeneous block phantom show an agreement within 4%. All transverse axis dose profiles in water, in bone, and lung-equivalent materials for beams using a HBT, have an agreement within 5%. Measured profiles of FBT beams in bone and lung-equivalent materials were higher than their computed counterparts resulting in an agreement within 2.5%, 5%, and 8% within solid water, bone, and lung, respectively. Conclusions: The proposed virtual point source model and characterization method can be used to compute absorbed dose in both the homogeneous and heterogeneous block phantoms within of 2%–8% of measured values, depending on the phantom and the beam quality. The authors’ results also provide experimental validation for their kV dose computation software, kVDoseCalc.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multisource inverse-geometry CT. Part II. X-ray source design and prototype

Purpose: This paper summarizes the development of a high-power distributed x-ray source, or “multisource,” designed for inverse-geometry computed tomography (CT) applications [see B. De Man et al., “Multisource inverse-geometry CT. Part I. System concept and development,” Med. Phys. 43, 4607–4616 (2016)]. The paper presents the evolution of the source architecture, component design (anode, emitter, beam optics, control electronics, high voltage insulator), and experimental validation. Methods: Dispenser cathode emitters were chosen as electron sources. A modular design was adopted, with eight electron emitters (two rows of four emitters) per module, wherein tungsten targets were brazed onto copper anode blocks—one anode block per module. A specialized ceramic connector provided high voltage standoff capability and cooling oil flow to the anode. A matrix topology and low-noise electronic controls provided switching of the emitters. Results: Four modules (32 x-ray sources in two rows of 16) have been successfully integrated into a single vacuum vessel and operated on an inverse-geometry computed tomography system. Dispenser cathodes provided high beam current (>1000 mA) in pulse mode, and the electrostatic lenses focused the current beam to a small optical focal spot size (0.5 × 1.4 mm). Controlled emitter grid voltage allowed the beam current to be varied for each source, providing the ability to modulate beam current across the fan of the x-ray beam, denoted as a virtual bowtie filter. The custom designed controls achieved x-ray source switching in <1 μs. The cathode-grounded source was operated successfully up to 120 kV. Conclusions: A high-power, distributed x-ray source for inverse-geometry CT applications was successfully designed, fabricated, and operated. Future embodiments may increase the number of spots and utilize fast read out detectors to increase the x-ray flux magnitude further, while still staying within the stationary target inherent thermal limitations.

60 APPLIED LIFE SCIENCES↗

TH-CD-207B-01: BEST IN PHYSICS (IMAGING): Development of High Brightness Multiple-Pixel X-Ray Source Using Oxide Coated Cathodes

Purpose: To develop and characterize a high brightness multiple-pixel thermionic emission x-ray (MPTEX) source. Methods: Multiple-pixel x-ray sources allow for designs of novel x-ray imaging techniques, such as fixed gantry CT, digital tomosynthesis, tetrahedron beam computed tomography, etc. We are developing a high-brightness multiple-pixel thermionic emission x-ray (MPTEX) source based on oxide coated cathodes. Oxide cathode is chosen as the electron source due to its high emission current density and low operating temperature. A MPTEX prototype has been developed which may contain up to 41 micro-rectangular oxide cathodes in 4 mm pixel spacing. Electronics hardware was developed for source control and switching. The cathode emission current was evaluated and x-ray measurements were performed to estimate the focal spot size. Results: The oxide cathodes were able to produce ∼110 mA cathode current in pulse mode which corresponds to an emission current density of 0.55 A/cm{sup 2}. The maximum kVp of the MPTEX prototype currently is limited to 100 kV due to the rating of high voltage feedthrough. Preliminary x-ray measurements estimated the focal spot size as 1.5 × 1.3 mm{sup 2}. Conclusion: A MPTEX source was developed with thermionic oxide coated cathodes and preliminary source characterization was successfully performed. The MPTEX source is able to produce an array of high brightness x-ray beams with a fast switching speed.

60 APPLIED LIFE SCIENCES↗

Stronger Efforts are Needed to Improve the Control of Radioactive Sources: An IAEA Perspective

High activity radioactive sources provide great benefit to humanity through their utilization in agriculture, industry, medicine, research and education, and the vast majority is used in well-controlled environments. None-the-less, control has been lost over a small fraction of those sources resulting in accidents of which some had serious - even fatal - consequences. In order to improve the existing situation, concerted national and international efforts are needed and, to some degree, are being implemented to strengthen the safety and security of sources in use, as well as to improve the control of disused sources located at numerous facilities throughout the world. More efforts must also be made to identify, recover, and bring into control vulnerable and orphan sources. The IAEA has been involved in efforts to bring about better control of radioactive sources for many years but since the events of September 2001 the amount of effort put into this area has increased considerably. This paper highlights IAEA work in this regard. This paper also discusses in some detail the overall nature of the problem with regards to disused sources and points out how there is still much to do in both improving the existing situation and ensuring the sustainability of control over radioactive sources for the future. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Management of Ir-192 Disused Sealed Sources with Long-Lived Radioactive Contaminants

Iridium-192 sealed sources are the most widely used sealed source in industrial applications in Brazil. They are not recyclable and in the end of the useful life, they are discarded as radioactive waste. The recommended management strategy of this waste is decay in storage and disposal as exempt waste because the half-life is only 73.8 days. Presently, thousands of Ir- 192 sources are under storage waiting release. Surprisingly, sources that were under storage for more than ten years and for which no measurable contact dose rate was expected still present significant remaining radioactivity. The examination of the gamma spectra of these sources showed the presence of Co-60 and the gamma emission lines from the Ir-192m2 isomer, the metastable isotope with half-life of 241 years, which is also formed by the irradiation of natural iridium. The aim of the study reported in this paper is to characterize the Ir-192 disused sources under interim storage at the Radioactive Waste Management Department, considering the presence of minor contaminants in the irradiated iridium and the fraction of the total initial activity of the sources that is attributable to that metastable isotope. The radioactive inventories at the end of the irradiation and after the decay period were predicted using the Scale 6.0 code and the results were compared with activity measurements of the disused sources by gamma spectrometry. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Flux Estimation of a PuBe source using Delayed Gamma Neutron Activation Analysis

For handling and storage of a highly radioactive source, it is necessary to have an accurate knowledge of the radioactive source as well as the neutron flux. Recently, due to radiation safety requirements, a PuBe alpha-neutron source at an activation facility at IIT-Kanpur had to be taken out of its original damaged howitzer and placed inside a new shielded container. While, this effort was successful in reducing the radiation dose, and making the setup safe for laboratory measurements, the new source moderator configuration left the new Pu-Be source spectrum unknown. Therefore, in this work we have used delayed gamma neutron activation analysis (DGNAA) of aluminum, copper, iron, manganese (found in iron), and silver for thermal neutron flux estimation of the Pu-Be neutron source. A series of DGNAA measurements with different samples were carried out to find the value of the average thermal neutron flux of a Pu-Be neutron source at Indian Institute of Technology-Kanpur. The order of the thermal neutron flux is found to be nearly 1.64 x 10{sup 5} excluding aluminum. Upon including aluminum, the value of thermal neutron flux decreases to 1.57x10{sup 5}. We have used common metals (like aluminum, silver, copper and iron) to calculate the thermal neutron flux. The calculated value of the thermal neutron flux is consistent for all the metals except for iron. Iron is giving a value almost four times larger than the average calculated value of the thermal neutron flux using other six samples. The reason is currently being investigated. The DGNAA technique came out to be a very useful technique. Now that we know the thermal neutron flux of the Pu-Be source, our future work will include improving the safety and shielding calculations for our activation facility at IIT-Kanpur. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Source complexity of the 2015 Mw 7.9 Bonin earthquake

The 30 May 2015 Mw 7.9 Bonin earthquake, one of the largest and deepest earthquakes ever recorded by modern seismology, provides a unique opportunity to study the source process and physical mechanisms of deep-focus earthquakes. We develop a novel back-projection technique that allows source imaging in full three-dimensional space with high depth resolution. Our results indicate an initial SW-NE bilateral source propagation followed by a northwest source extension. The multiple-source inversion reveals a two-step source process with propagating directions near-perpendicular to each other, consistent with the 3D back-projection result. The spatial distribution and focal mechanisms of the sub-events cannot be modeled by a single planar rupture, which may display a curved rupture plane or sub-events crossing multiple fault interfaces. Thus, the complex source process can be best explained by stress or structure heterogeneity within the deep slab.

58 GEOSCIENCES↗

Intense Photoneutron Sources For Nuclear Material Detection

Intense neutron sources are essential for cargo inspection for a broad range of threats from explosives, to contraband, to nuclear materials and especially SNM (Special Nuclear Materials). To be effective over a wide range of cargo materials, in particular for hydrogenous cargo such as food, and to offer practical inspection times, the neutron source must be very strong, typically >10{sup 10} neutrons per second. Unfortunately there are currently no reasonably compact and economical neutron generators with the required intensities. The insufficiency and inadequacy of intense neutron sources are especially conspicuous in the {<=}2.5 MeV range (low voltage (d,D) generator). This energy range is needed if the strong signature of prompt fission neutrons ({approx_equal}3 per fission) is to be detected and discerned from the numerous source neutrons. The photonuclear reactions of x-rays from commercial linacs in appropriate converters can provide ample intensities of neutrons. These converters have a very low ({gamma},n) energy threshold: 1.67 MeV for beryllium and 2.23 MeV for deuterium. The intense x-ray beams provided by commercial x-ray systems, more than compensate for the relatively low ({gamma},n) cross-sections which are in the milli-barn range. The choice of converter material, the geometrical shape, dimensions and location relative to the x-ray source, determine the efficiency of the neutron conversion. For electron accelerators with less than 10 MeV, the preferred converters, Be and D{sub 2}O, are also very good neutron moderators. Thus, while increasing the converters' thickness leads to an increase in the overall neutron yield, this causes the softening of the neutron spectrum, which reduces the neutron penetration especially in hydrogenous cargos. Photoneutron sources can be optimized to meet specific needs such as maximum fission signals in various cargo materials of interest. Efficient photoneutron sources with different energy spectra were investigated. Conversion efficiency of more than 10-4 neutron per 9 MeV electron yielding neutron intensities of more than 10{sup 11} n/s for commercial 100 {mu}Amp electron accelerators has been modeled and designed. The simulation was validated in laboratory experiments using small Be and D{sub 2}O converters.

43 PARTICLE ACCELERATORS↗