Search NASA⌕ Search

SEARCH · Search NASA

Results for “test effectiveness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

MO-FG-BRA-07: Theranostic Gadolinium-Based AGuIX Nanoparticles for MRI-Guided Radiation Therapy

Purpose: AGuIX are gadolinium-based nanoparticles, initially developed for MRI, that have a potential role in radiation therapy as a radiosensitizer. Our goal is to demonstrate that these nanoparticles can both be used as an MRI contrast agent, as well as to obtain local dose enhancement in a pancreatic tumor when delivered in combination with an external beam irradiation. Methods: We performed in vitro cell uptake and radiosensitization studies of a pancreatic cancer cell line in a low energy (220kVp) beam, a standard clinical 6MV beam (STD) and a flattening filter free clinical 6MV beam (FFF). After injection of 40mM of nanoparticles, a biodistribution study was performed in vivo on mice with subcutaneous xenograft pancreatic tumors. In vivo radiation therapy studies were performed at the time point of maximum tumor uptake. Results: The concentration of AGuIX nanoparticles in Panc-1 pancreatic cancer cells, determined in vitro by MRI and ICPMS, peaks after 30 minutes with 0.3% of the initial concentration (5mg/g). Clonogenic assays show a significant effect (p<0.05) when the AGuIX are coupled with MV photon irradiation (DEF20%=1.31). Similar AGuIX tumor uptake is found in vivo by both MRI and ICPMS 30 minutes after intravenous injection. For long term survival studies, the choice of the radiation dose is determined with 5 control groups (3mice/group) irradiated with 0, 5, 10, 15, and 20Gy. Afterwards, 4 groups (8mice/group) are used to evaluate the effect of the nanoparticles. A Logrank test is performed as a statistical test to evaluate the effect of the nanoparticles. Conclusion: The combination of the MRI contrast and radiosensitization properties of gadolinium nanoparticles reveals a strong potential for usage with MRI-guided radiation therapy.

60 APPLIED LIFE SCIENCES↗

Contrasting Foraging Patterns: Testing Resource-Concentration and Dilution Effects with Pollinators and Seed Predators

Resource concentration effects occur when high resource density patches attract and support more foragers than low density patches. In contrast, resource dilution effects can occur if high density patches support fewer consumers. In this study, we examined the foraging rates of pollinators and seed predators on two perennial plant species (Rudbeckia triloba and Verbena stricta) as functions of resource density. Specifically, we examined whether resource-dense patches (densities of flower and seeds on individual plants) resulted in greater visitation and seed removal rates, respectively. We also examined whether foraging rates were context-dependent by conducting the study in two sites that varied in resource densities. For pollinators, we found negative relationships between the density of flowers per plant and visitation rates, suggesting dilution effects. For seed predators, we found positive relationships consistent with concentration effects. Saturation effects and differences in foraging behaviors might explain the opposite relationships; most of the seed predators were ants (recruitment-based foragers), and pollinators were mostly solitary foragers. We also found that foraging rates were site-dependent, possibly due to site-level differences in resource abundance and consumer densities. These results suggest that these two plant species may benefit from producing as many flowers as possible, given high levels of pollination and low seed predation.

54 ENVIRONMENTAL SCIENCES↗

Local Doppler broadening effects from thermal neutrons during transient testing

Doppler broadening refers to the changing of a nuclear cross-section as a response to kinetic energy changes from interaction on a single-nucleus level. Interactions between irradiated particles causes a change in vibration of the nucleus, which is commonly correlated to the overall material's temperature, affecting how irradiate materials interact with additional incident particles. This phenomenon poses unique problems when specifically addressing transient conditions in the Transient Reactor Test Facility (TREAT) at Idaho National Laboratories (INL) because the facility is mainly concerned with in the thermal energy range (velocities beneath 2200 m/s) interacting with a plethora of alloyed metals inserted into the experimental test train slot of the facility. This work investigates the past validation of codes for on-the-fly (OTF) Doppler broadening programs and cross references them with experiments to determine the thermal range and limitations of the TREAT facility for transient conditions. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Novel Protocol for Acute In Situ Ecotoxicity Test Using Native Crustaceans Applied to Groundwater Ecosystems

Current standardized laboratory test protocols use model species that have limitations to accurately assess native species responses to stressors. We developed and tested a novel acute in situ protocol for testing field-collected organisms. We used Asellus aquaticus and NaCl as a reference toxicant to test for the effects of location (laboratory vs. in situ), medium (synthetic vs. field water), substrate (presence vs. absence), and protocol replicability. We further tested the protocol using groundwater-adapted isopods: Proasellus assaforensis for the effect of location, P. cavaticus of medium and P.lusitanicus of substrate. Our results showed that A.aquaticus’ lethality obtained with the novel acute in situ protocol did not significantly differ from those from laboratory testing. However, laboratory tested P.assaforensis showed a higher sensitivity, suggesting that its acclimation to laboratory conditions might have pernicious effects. A. aquaticus and P. cavaticus showed a higher mortality using synthetic medium in situ and under laboratory conditions, which overestimated the stressor’s effect. Besides, substrate use had no significant effect. The novel acute in situ protocol allows the use of native species under realistic scenarios. It is particularly well adapted for assessing the risk of groundwater ecosystems but it can be applied to a wide range of ecosystems.

Castaño-Sánchez, Andrea↗

Quantifying early stage irradiation damage from nanoindentation pop-in tests

Early stage irradiation effects on incipient plasticity are quantitatively investigated in single-crystalline molybdenum using nanoindentation pop-in tests. Defects produced under low-dose ion irradiations, even when they are hardly detected by ion-channeling technique, can significantly reduce the critical stress for the elastic-plastic transition, through acting as heterogeneous dislocation nucleation sources. Here, the density and strength of defects are derived using a unified model convoluting homogeneous and heterogeneous mechanisms. In addition to the increased defect density, defect strength is found to decrease with increasing irradiation dose, suggesting a growth in defect size, which is further evidenced by combined analyses between pop-in and hardness tests.

36 MATERIALS SCIENCE↗

EFFECTS OF SIZE AND GEOMETRY ON THE EQUIBIAXIAL FLEXURAL TEST OF FINE GRAINED NUCLEAR GRAPHITE

Reduction of specimen size is an essential requirement for neutron irradiation effect studies of materials since space in nuclear reactors for those studies are often very limited and costly. Reducing the specimen size can dramatically reduce the cost of these studies, the irradiation exposure to personnel involved in post irradiation examination and the volume of radioactive waste. In this study, 4 specimen sizes were systematically varied to examine the size effect on the equibiaxial flexure test of fine grain nuclear graphite in non-irradiated conditions at room temperature. A statistically significant sample population of 30 was used for each specimen geometry or dimension. The results showed that the round shaped samples followed weibull distribution with Weibull modulus of 25 to 35. The average strength followed the trend of the weakest link theory. The 2 sizes of square shaped samples had Weibull modulus of 29 and 40. Data from round and square samples agree with others reasonably and collectively follow the Weibull scaling theory. It is concluded that the equibiaxial flexural test using adequate population of small specimens provides useful and reliable information on the statistical strength properties for fine-grained nuclear graphite materials.

Shih, Chunghao↗

Radium and Thorium Sorption by Monosodium Titanate (MST) and Modified MST (mMST)

A series of tests were planned to examine the removal of Ra and Th by monosodium titanate (MST) and modified monosodium titanate (mMST). Simulated waste solutions were prepared containing Ra and Th, along with Sr, Np, Pu, and U. Following simulant preparation the simulants were filtered through 0.45-m filters. Analysis of the simulants indicated no Th in the filtered solution. This is due to the very low solubility of Th in alkaline solutions. Based on the reported detection limits for 228 Th by gamma analyses, the solubility of Th in the simulant solutions is < 3.0E-10 g/L or < 1.3E-12 M. Therefore, data could not be obtained regarding the removal of Th by MST and mMST; however, testing proceeded to examine the removal of Ra. Sorption testing indicated that Ra, like Sr, is very rapidly removed from solution by both MST and mMST. The Ra concentration in solution fell below the method detection limit (MDL) within 30 minutes of contact with MST, and within 2 hours of contact with mMST, when tested at 25 °C using a 5.6 M Na simulant. Additional testing examined the effects of ionic strength and temperature on the MST and mMST performance. Results from these tests showed that the majority of samples still reached a Ra concentration below the MDL, indicating excellent removal. For the highest ionic strength solution (6.6 M Na), there did appear to be a slight decrease in the Ra removal by mMST, as indicated by a larger number of samples just above the MDL. The effect of temperature on 226 Ra removal is indeterminate for either MST or mMST in the temperature range (25-60 °C) and concentrations studied since the final soluble concentration of Ra remained at or below the detection limits for all tests. Desorption testing was also performed using decontaminated salt solution (DSS) diluted to sodium concentrations of 2 M and 0.5 M, to represent the intermediate and final stages of washing. Results from these tests indicated no desorption of any sorbents, with the exception of Pu from mMST, which desorbed slightly (0.02%). Rather, the testing showed additional sorption of sorbates, likely due to the higher sorbent concentrations in these tests compared to the concentrations used for loading (i.e. 13 g/L vs. 0.4 g/L). SRNL recommends additional testing to confirm the low solubility of Th in a range of simulants representing SRS HLW. We also recommend additional sorption testing with simulants containing a higher concentration of 226Ra, to allow for the determination of actual DF values, rather than the minimum DF values reported here.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A kernel machine method for detecting higher order interactions in multimodal datasets: Application to schizophrenia

Technological advances are enabling us to collect multimodal datasets at an increasing depth and resolution while with decreasing labors. Understanding complex interactions among multimodal datasets, however, is challenging. Here in this study, we tested the interaction effect of multimodal datasets using a novel method called the kernel machine for detecting higher order interactions among biologically relevant multimodal data. Using a semiparametric method on a reproducing kernel Hilbert space, we formulated the proposed method as a standard mixed-effects linear model and derived a score-based variance component statistic to test higher order interactions between multimodal datasets. The method was evaluated using extensive numerical simulation and real data from the Mind Clinical Imaging Consortium with both schizophrenia patients and healthy controls. Our method identified 13-triplets that included 6 gene-derived SNPs, 10 ROIs, and 6 gene-specific DNA methylations that are correlated with the changes in hippocampal volume, suggesting that these triplets may be important for explaining schizophrenia-related neurodegeneration. The performance of the proposed method is compared with the following methods: test based on only first and first few principal components followed by multiple regression, and full principal component analysis regression, and the sequence kernel association test. With strong evidence (p-value ≤0.000001), the triplet (MAGI2, CRBLCrus1.L, FBXO28) is a significant biomarker for schizophrenia patients. This novel method can be applicable to the study of other disease processes, where multimodal data analysis is a common task.

59 BASIC BIOLOGICAL SCIENCES↗

Determination of Arsenic Content in Water Using a Silver Coordination Polymer

In this report, we describe a practical method for the colorimetric determination of dissolved inorganic arsenic content in water samples, using a silver coordination polymer as the sensing material. We demonstrate that a crystalline polymer framework can be used to stabilize silver(I) ions, greatly reducing both photosensitivity and water solubility, while still affording sufficient reactivity to detect arsenic in water samples at low parts-per-billion (ppb) levels. Test strips fabricated with the silver-based polymer are shown to be effective for field tests of groundwater under real-world operating conditions and display performance that is competitive with commercially available mercury-based test strips. Spectroscopic methods are also used to probe the reaction products formed, in order to better understand the sensing mechanism. Thus, our work provides the foundation for an improved field test that could be deployed to help manage groundwater usage in regions where arsenic contamination is problematic but sophisticated lab testing is not readily available.

36 MATERIALS SCIENCE↗

A section 110 evaluation of the 10,500-foot blast line civil effects structures and military trenches associated with the apple-2 test, area 1, nevada national security site, nye county, nevada

The U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office (NNSA/NFO) has tasked Desert Research Institute (DRI) with identifying and evaluating additional resources that contribute to the significance of the Apple-2 Historic District as part of a Section 110 effort. Apple-2 was a 1955 atmospheric test in which the Federal Civil Defense Administration (FCDA) conducted an extensive civil effects program named Operation Cue. The objective of Operation Cue was to understand the blast and thermal effects of the test by using a simulated community of residential buildings, industrial structures, utilities, and commercial equipment arranged at various distances from ground zero (GZ). Military operations conducted by the Department of Defense (DoD) as part of the Desert Rock VI exercise were also associated with the Apple-2 test. The Apple-2 Historic District was originally defined in 2000 by Johnson and Edwards as 15 highly visible contributing elements dispersed across the landscape. Since its original recording, DRI has conducted additional archival research and this report details the identification and evaluation results of testing-related material remains at a distance of 10,500 ft from the Apple-2 GZ. Between 2017 and 2020, DRI conducted fieldwork at 10,500 ft from the Apple-2 GZ, revisited previously recorded contributing elements, and identified and evaluated newly recorded resources associated with Operation Cue as well as DoD operations. In total, DRI revisited or newly identified 15 principal resources. Of these, 13 are located within the historic district and contribute to the district’s significance. A set of military trenches and the associated material remains are discontiguous from the district, but also contribute to the district’s significance.

54 ENVIRONMENTAL SCIENCES↗

REGULATORY TESTING AND 3D SCANNING METHODOLOGY OF THE DPP-1 TYPE SHIPPING CONTAINER FOR NCT AND HAC TESTS

The safe transportation of radioactive material using appropriately designed and certified transportation packages is important to protect the public and environment. In the United States of America all transportation of radioactive material is regulated by the Department of Transportation (DOT) along with input by the Nuclear Regulatory Commission (NRC). All packages that contain radioactive material requires that it be transported and regulated by the requirements set by the DOT Class 7 hazardous material transportation. Federal regulations place strict administrative controls on the transport of radioactive materials. The two main goals for transporting radioactive materials are 1. Safety should be the primarily focused on the package because it is the first line of defense. 2. Package integrity should be directly related to the degree of the hazard of the radioactive material contents. The two-part goal ensures that the right package is used. Type B packages are designed to transport radioactive materials with the highest level of radioactivity. Examples of material transported in Type B packagings include spent nuclear fuel, high-level radioactive waste, and high concentrations of other radioactive materials. The purpose of this test protocol is to determine the effects of drop and thermal testing on package performance in a Type B shipping package (DPP-1). Required physical tests for the DPP-1 package include free drop, crush, puncture, penetration, compression, vibration, water spray, water immersion, and thermal. The preparation, regulatory testing, and post-test evaluation of a Type B shipping package tested to the 10 CFR 71.71 and 10 CFR 71.73 requirements will be presented. Six packages were tested and the responses when subjected to the HAC sequence of free drop, puncture, and thermal tests according to 10 CFR 71.73(c)(1), (c)(2), (c)(3) and (c)(4) were measured. The Free Drop, Crush and Puncture tests were performed at the NTRC in Knoxville, TN, and the Thermal tests were performed Southwest Research Institute in San Antonio, TX. The test units were subjected to a pre-operational leak testing before the NCT and HAC tests and a post-operational leak test and a helium leak test once regulatory testing was complete. Finally, all test units were scanned with a handheld blue light scanner to capture a 3D CAD geometry of the test units in the deformed shape. The handheld scanner provided the most effective and reliable way to acquire accurate 3D measurements of the test unit. The scanned geometry was sectioned in areas with deformation and the cross-section profile was measured to determine accurate and repeatable results of the deformed shape of the test units.

Martinez, Oscar↗

Influences of Quench Cooling Rate on Microstructure and Corrosion Resistance of Al-Cu-Mg Alloy Based on the End-Quenching Test

To investigate the effects of the quench cooling rate on corrosion resistance of Al-Cu-Mg alloy, an end-quenching test was conducted and the microstructures at different cooling rates were observed by SEM and TEM. Additionally, the corrosion resistance was characterized by an intergranular corrosion test and electrochemical test. Moreover, the finite element method was applied to simulate the end quenching process. The results indicate that the actual end quenching process can be approximated as one-dimensional heat transfer, and the cooling rate varies at different cooling distances. By affecting the microstructures, decreasing the cooling rate leads to a decline in the corrosion properties. Low cooling rates coarsen the constituent particles and grain boundary particles, resulting in a wide precipitation-free zone and an increase in the intensity of corrosion reactions. A high cooling rate concentrates on the intragranular precipitant, which can reduce the pitting depth and represents a conversion from localized corrosion to general corrosion.

36 MATERIALS SCIENCE↗

IAEA Coordinated Research Project on Master Curve Approach to Monitor Fracture Toughness of RPV Steels: Final Results of the Experimental Exercise to Support Constraint Effects

The precracked Charpy single-edge notched bend, SE(B), specimen (PCC) is the most likely specimen type to be used for determination of the reference temperature, T0, with reactor pressure vessel (RPV) surveillance specimens. Unfortunately, for many RPV steels, significant differences have been observed between the T0 temperature for the PCC specimen and that obtained from the 25-mm thick compact specimen [1TC(T)], generally considered the standard reference specimen for T0. This difference in T0 has often been designated a specimen bias effect, and the primary focus for explaining this effect is loss of constraint in the PCC specimen. The International Atomic Energy Agency (IAEA) has developed a coordinated research project (CRP) to evaluate various issues associated with the fracture toughness Master Curve for application to light-water RPVs. Topic Area 1 of the CRP is focused on the issue of test specimen geometry effects, with emphasis on determination of T0 with the PCC specimen and the bias effect. Topic Area 1 has an experimental part and an analytical part. Participating organizations for the experimental part of the CRP performed fracture toughness testing of various steels, including the reference steel JRQ (A533-B-1) often used for IAEA studies, with various types of specimens under various conditions. Additionally, many of the participants took part in a round robin exercise on finite element modeling of the PCVN specimen, discussed in a separate paper. Results from fracture toughness tests are compared with regard to effects of specimen size and type on the reference temperature T0. It is apparent from the results presented that the bias observed between the PCC specimen and larger specimens for Plate JRQ is not nearly as large as that obtained for Plate 13B (-11 C vs -37 C) and for some of the results in the literature (bias values as much as -45 C). This observation is consistent with observations in the literature that show significant variations in the bias that are dependent on the specific materials being tested. There are various methods for constraint adjustments and two methods were used that reduced the bias for Plate 13B from -37 C to -13 C in one case and to -11 C in the second case. Unfortunately, there is not a consensus methodology available that accounts for the differences observed with different materials. Increasing the Mlim value in the ASTM E-1921 to ensure no loss of constraint for the PCC specimen is not a practicable solution because the PCC specimen is derived from CVN specimens in RPV surveillance capsules and larger specimens are normally not available. Resolution of these differences are needed for application of the master curve procedure to operating RPVs, but the research needed for such resolution is beyond the scope of this CRP.

36 MATERIALS SCIENCE↗

An effective “three-in-one” screening assay for testing drug and nanoparticle toxicity in human endothelial cells

Evaluating nanoparticle (NP) toxicity in human cell systems is a fundamental requirement for future NP biomedical applications. In this study, we have designed a screening assay for assessing different types of cell death induced by NPs in human umbilical vein endothelial cell (HUVEC) culture. This assay consists of WST-8, LDH and Hoechst 33342 staining, all performed in one well, which enables an evaluation of cell viability, necrosis and apoptosis, respectively, in the same cell sample. The 96-well format and automated processing of fluorescent images enhances the assay rapidity and reproducibility. After testing the assay functionality with agents that induced different types of cell death, we investigated the endothelial toxicity of superparamagnetic iron oxide nanoparticles (SPIONs, 8 nm), silica nanoparticles (SiNPs, 7–14 nm) and carboxylated multiwall carbon nanotubes (CNTCOOHs, 60 nm). Our results indicated that all the tested NP types induced decreases in cell viability after 24 hours at a concentration of 100 μg/ml. SPIONs caused the lowest toxicity in HUVECs. By contrast, SiNPs induced pronounced necrosis and apoptosis. A time course experiment showed the gradual toxic effect of all the tested NPs. CNTCOOHs inhibited tetrazolium derivatives at 100 μg/ml, causing false negative results from the WST-8 and LDH assay. In summary, our data demonstrate that the presented “three-in-one” screening assay is capable of evaluating NP toxicity effectively and reliably. Due to its simultaneous utilization of two different methods to assess cell viability, this assay is also capable of revealing, if NPs interfere with tetrazolium salts.

59 BASIC BIOLOGICAL SCIENCES↗

Steep Decay Phase Shaped by the Curvature Effect. I. Flux Evolution

The curvature effect may be responsible for the steep decay phase observed in gamma-ray bursts. To test the curvature effect with observations, the zero time point t {sub 0} adopted to plot the observer time and flux on a logarithmic scale should be appropriately selected. In practice, however, the true t {sub 0} cannot be directly constrained from the data. Thus, we move t {sub 0} to a certain time in the steep decay phase, which can be easily identified. In this situation, we derive an analytical formula to describe the flux evolution of the steep decay phase. The analytical formula reads as F{sub ν}∝(1+ t-tilde {sub obs}/ t-tilde {sub c}){sup −α}, with α( t-tilde {sub obs})=2+∫{sub 0}{sup log(1+ t-tilde {sub o}{sub b}{sub s}/ t-tilde {sub c})} β(τ)d[log(1+τ/ t-tilde {sub c})]/log(1+ t-tilde {sub obs}/ t-tilde {sub c}), where F {sub ν} is the flux observed at frequency ν, t-tilde {sub obs} is the observer time by setting t {sub 0} at a certain time in the steep decay phase, β is the spectral index estimated around ν, and t-tilde {sub c} is the decay timescale of the phase with t-tilde {sub obs}⩾0. We test the analytical formula with the data from numerical calculations. It is found that the analytical formula presents a good estimate of the evolution of the flux shaped by the curvature effect. Our analytical formula can be used to confront the curvature effect with observations and estimate the decay timescale of the steep decay phase.

79 ASTRONOMY AND ASTROPHYSICS↗