Search NASA⌕ Search

SEARCH · Search NASA

Results for “time resolved”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Time Resolved Studies of ZnO(Eu) Nanostructure Luminescence Using Short Synchrotron Radiation Pulses

X-ray excited optical luminescence (XEOL) is a well established technique to study nano structured light emitting materials. XEOL bares the essential features necessary for the study of advanced nano structured materials like element specifity, good quantum efficiency, and easy approach for time resolution. Being sensitive to the geometry of the material on a nano-scale, luminescence gives insight into the phenomenologic correlation of structural, optical, and electronic properties. Besides structural aspects we study the time behavior of nanostructured ZnO (Eu) in a pump-probe like experiment, using the time structure of synchrotron radiation.

43 PARTICLE ACCELERATORS↗

Time-Resolved Grazing Incidence X-Ray Absorption Spectroscopy for the In Situ Investigation of the Initial Stages of Sputter-Deposited Copper Thin Films

The sputter deposition and the growth of thin copper films on float glass substrates are in situ studied using grazing incidence, reflection mode X-ray absorption fine structure spectroscopy with subsecond time resolution. The experimental data are compared with model calculations, assuming the presence of crystalline, face-centered cubic metallic Cu nanostructures. From a detailed analysis of the measured spectra, the film thickness as well as the surface roughness is determined, leading to a detailed understanding of the films growth as a function of the sputter deposition time. In particular, different stages of film growth can clearly be distinguished from the fits of the experimental data. The results suggest the formation of isolated, approximately nm-sized copper clusters in the initial phase of the film deposition for the first few seconds, a coalescence phase with a nominal thickness of ≈1.5–2.8 nm, constant roughness of about 1.4 nm for the subsequent ≈5 s, and finally 3D growth of the Cu crystallites in the film for later stages of film growth. Further prospects of the methodology are given.

36 MATERIALS SCIENCE↗

Design of multi neutron-to-gamma converter array for measuring time resolved ion temperature of inertial confinement fusion implosions

The ion temperature varying during inertial confinement fusion implosions changes the amount of Doppler broadening of the fusion products, creating subtle changes in the fusion neutron pulse as it moves away from the implosion. A diagnostic design to try to measure these subtle effects is introduced—leveraging the fast time resolution of gas Cherenkov detectors along with a multi-puck array that converts a small amount of the neutron pulse into gamma-rays, one can measure multiple snapshots of the neutron pulse at intermediate distances. Further, precise measurements of the propagating neutron pulse, specifically the variation in the peak location and the skew, could be used to infer time-evolved ion temperature evolved during peak compression.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Protein Structural Dynamics Revealed by Time-Resolved X-ray Solution Scattering

One of the most important questions in biological science is how a protein functions. When a protein performs its function, it undergoes regulated structural transitions. In this regard, to better understand the underlying principle of a protein function, it is desirable to monitor the dynamic evolution of the protein structure in real time. To probe fast and subtle motions of a protein in physiological conditions demands an experimental tool that is not only equipped with superb spatiotemporal resolution but also applicable to samples in solution phase.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-resolved ion imaging at free-electron lasers using TimepixCam

In this paper, the application of a novel fast optical-imaging camera, TimepixCam, to molecular photoionization experiments using the velocity-map imaging technique at a free-electron laser is described. TimepixCam is a 256 × 256 pixel CMOS camera that is able to detect and time-stamp ion hits with 20 ns timing resolution, thus making it possible to record ion momentum images for all fragment ions simultaneously and avoiding the need to gate the detector on a single fragment. This allows the recording of significantly more data within a given amount of beam time and is particularly useful for pump–probe experiments, where drifts, for example, in the timing and pulse energy of the free-electron laser, severely limit the comparability of pump–probe scans for different fragments taken consecutively. Finally, in principle, this also allows ion–ion covariance or coincidence techniques to be applied to determine angular correlations between fragments.

47 OTHER INSTRUMENTATION↗

SU-C-207A-05: Feature Based Water Equivalent Path Length (WEPL) Determination for Proton Radiography by the Technique of Time Resolved Dose Measurement

Purpose: Studies show that WEPL can be determined from modulated dose rate functions (DRF). However, the previous calibration method based on statistics of the DRF is sensitive to energy mixing of protons due to scattering through different materials (termed as range mixing here), causing inaccuracies in the determination of WEPL. This study intends to explore time-domain features of the DRF to reduce the effect of range mixing in proton radiography (pRG) by this technique. Methods: An amorphous silicon flat panel (PaxScan™ 4030CB, Varian Medical Systems, Inc., Palo Alto, CA) was placed behind phantoms to measure DRFs from a proton beam modulated by a specially designed modulator wheel. The performance of two methods, the previously used method based on the root mean square (RMS) and the new approach based on time-domain features of the DRF, are compared for retrieving WEPL and RSP from pRG of a Gammex phantom. Results: Calibration by T{sub 80} (the time point for 80% of the major peak) was more robust to range mixing and produced WEPL with improved accuracy. The error of RSP was reduced from 8.2% to 1.7% for lung equivalent material, with the mean error for all other materials reduced from 1.2% to 0.7%. The mean error of the full width at half maximum (FWHM) of retrieved inserts was decreased from 25.85% to 5.89% for the RMS and T{sub 80} method respectively. Monte Carlo simulations in simplified cases also demonstrated that the T{sub 80} method is less sensitive to range mixing than the RMS method. Conclusion: WEPL images have been retrieved based on single flat panel measured DRFs, with inaccuracies reduced by exploiting time-domain features as the calibration parameter. The T{sub 80} method is validated to be less sensitive to range mixing and can thus retrieve the WEPL values in proximity of interfaces with improved numerical and spatial accuracy for proton radiography.

60 APPLIED LIFE SCIENCES↗

A time-resolved laser induced fluorescence study on the ion velocity distribution function in a Hall thruster after a fast current disruption

The temporal characteristics of the Xe{sup +} ion axial velocity distribution function (VDF) were recorded in the course of low-frequency discharge current oscillations ({approx}14 kHz) of the 5 kW class PPS X000 Hall thruster. The evolution in time of the ion axial velocity component is monitored by means of a laser induced fluorescence diagnostic tool with a time resolution of 100 ns. As the number of fluorescence photons is very low during such a short time period, a homemade pulse-counting lock-in system was used to perform real-time discrimination between background photons and fluorescence photons. The evolution in time of the ion VDF was observed at three locations along the thruster channel axis after a fast shutdown of the thruster power. The anode discharge current is switched off at 2 kHz during 5 {mu}s without any synchronization with the current oscillation cycle. This approach allows to examine the temporal behavior of the ion VDF during decay and ignition of the discharge as well as during forced and natural plasma oscillations. Measurements show that the distribution function of the axial component of the Xe{sup +} ion does change periodically in time with a frequency close to the current oscillation frequency in both forced and natural cases. The ion density and the mean velocity are found to oscillate, whereas the velocity dispersion stays constant, which indicates that ionization and acceleration layers have identical dynamics. Finally, variations over time in the electric field are for the first time experimentally evidenced in a crossed-field discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-resolved x-ray and extreme ultraviolate spectrometer for use on the National Spherical Torus Experiment

We describe upgrades to a compact grazing-incidence spectrometer utilized on the National Spherical Torus Experiment for monitoring light and heavy impurities. A fast-readout charge couple device camera has been implemented that allows the recording of spectra with up to 25 ms time integration. This capability is used to study the time evolution of the K-shell emission of hydrogenlike and heliumlike boron, carbon, nitrogen, and oxygen between 10 and 65 A. Different camera positioning pieces have been employed to extend the possible spectral range to as high as 140. Several lines that cannot be ascribed to the usual elements found in the plasma have been observed in this spectral range, although often only in a few isolated discharges.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-Resolved Stochastic Dynamics of Quantum Thermal Machines

Steady-state quantum thermal machines are typically characterized by a continuous flow of heat between different reservoirs. However, at the level of discrete stochastic realizations, heat flow is unraveled as a series of abrupt quantum jumps, each representing an exchange of finite quanta with the environment. Here, in this work, we present a framework that resolves the dynamics of quantum thermal machines into cycles classified as enginelike, coolinglike, or idle. We analyze the statistics of individual cycle types and their durations, enabling us to determine both the fraction of cycles useful for thermodynamic tasks and the average waiting time between cycles of a given type. Central to our analysis is the notion of intermittency, which captures the operational consistency of the machine by assessing the frequency and distribution of idle cycles. Our framework offers a novel approach to characterizing thermal machines, with significant relevance to experiments involving mesoscopic transport through quantum dots.

full counting statistics↗

Time-resolved spectroscopy measurements of hydrogen-alpha, -beta, and -gamma emissions

Hydrogen emission spectroscopy results are reported following laser-induced optical breakdown with infrared Nd:YAG laser radiation focused into a pulsed methane flow. Measurements of Stark-broadened atomic hydrogen-alpha, -beta, and -gamma lines show electron number densities of 0.3 to 4x10{sup 17} cm{sup -3} for time delays of 2.1 to 0.4 {mu}s after laser-induced optical breakdown. In methane flow, recombination molecular spectra of the {delta}{nu}=+2 progression of the C2 Swan system are discernable in the H{beta} and H{gamma} plasma emissions within the first few microseconds. The recorded atomic spectra indicate the occurrence of hydrogen self-absorption for pulsed CH4 flow pressures of 2.7x10{sup 5} Pa (25 psig) and 6.5x10{sup 5} Pa (80 psig)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Probing time-resolved plasma-driven solution electrochemistry in a falling liquid film plasma reactor: Identification of HO$^−_2$ as a plasma-derived reducing agent

Many applications involving plasma–liquid interactions depend on the reactive processes occurring at the plasma–liquid interface. In this article, we report on a falling liquid film plasma reactor allowing for in situ optical absorption measurements of the time-dependence of the ferricyanide/ferrocyanide redox reactivity, complemented with ex situ measurement of the decomposition of formate. We found excellent agreement between the measured decomposition percentages and the diffusion-limited decomposition of formate by interfacial plasma-enabled reactions, except at high pH in thin liquid films, indicating the involvement of previously unexplored plasma-induced liquid phase chemistry enabled by long-lived reactive species. We also determined that high pH facilitates a reduction-favoring environment in ferricyanide/ferrocyanide redox solutions. In situ conversion measurements of a 1:1 ferricyanide/ferrocyanide redox mixture exceed the measured ex situ conversion and show that conversion of a 1:1 ferricyanide/ferrocyanide mixture is strongly dependent on film thickness. We identified three dominant processes: reduction faster than ms time scales for film thicknesses >100 µm, •OH-driven oxidation on time scales of <10 ms, and reduction on 15 ms time scales for film thickness <100 µm. We attribute the slow reduction and larger formate decomposition at high pH to HO$^−_2$ formed from plasma-produced H 2 O 2 enabled by the high pH at the plasma–liquid interface as confirmed experimentally and by computed reaction rates of HO$^−_2$ with ferricyanide. Overall, this work demonstrates the utility of liquid film reactors in enabling the discovery of new plasma-interfacial chemistry and the utility of atmospheric plasmas for electrodeless electrochemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fidelity of a Time-Resolved Imaging Diagnostic for Electron Beam Profiles

An optical tomographic diagnostic instrument has been fielded at the Dual-Axis Radiographic Hydrodynamic Test Facility at Los Alamos National Laboratory. Four optical lines of sight create projections of an image of an electron beam on a Cerenkov target, which are relayed via optical fiber to streak cameras. From these projections, a reconstruction algorithm creates time histories of the beam’s cross section. The instrument was fielded during and after facility commissioning, and tomographic reconstructions reported beam parameters. Results from reconstructions and analysis are noted.

Dual-Axis Radiographic Hydrodynamic Test, DARHT, e↗

(U) Implementation and demonstration of a time-resolved pyrometry/spectroscopy capability in shock compression experiments on metal oxide powders

Temperature is notably the most difficult quantity to measure in shock compression experiments; however, it is critical for accurately constraining theoretical or tabular equations of state. Until now, the temperature achieved during the shock loading of porous materials could only be calculated. The technique presented in this report measures, for the first time, the shocked temperature of porous systems.

36 MATERIALS SCIENCE↗

Time-Resolved X-Ray and Extreme Ultraviolet Spectrometer for Use on the National Spherical Torus Experiment

We describe upgrades to a compact grazing-incidence spectrometer utilized on the National Spherical Torus Experiment (NSTX) for monitoring light and heavy impurities . A fast-readout charge couple device (CCD) camera has been implemented that allows the recording of spectra with up to 25 ms time integration. This capability is used to study the time evolution of the K-shell emission of hydrogenlike and heliumlike boron, carbon, nitrogen, and oxygen between 10 and 65 {angstrom}. Different camera positioning pieces have been employed to extend the possible spectral range to as high as 140. Several lines that cannot be ascribed to the usual elements found in the plasma have been observed in this spectral range, though often only in a few isolated discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

M DWARF FLARES FROM TIME-RESOLVED SLOAN DIGITAL SKY SURVEY SPECTRA

We have identified 63 flares on M dwarfs from the individual component spectra in the Sloan Digital Sky Survey (SDSS) using a novel measurement of emission-line strength called the Flare Line Index. Each of the {approx}38,000 M dwarfs in the SDSS low-mass star spectroscopic sample of West et al. was observed several times (usually 3-5) in exposures that were typically 9-25 minutes in duration. Our criteria allowed us to identify flares that exhibit very strong H{alpha} and H{beta} emission-line strength and/or significant variability in those lines throughout the course of the exposures. The flares we identified have characteristics consistent with flares observed by classical spectroscopic monitoring. The flare duty cycle for the objects in our sample is found to increase from 0.02% for early M dwarfs to 3% for late M dwarfs. We find that the flare duty cycle is larger in the population near the Galactic plane and that the flare stars are more spatially restricted than the magnetically active but non-flaring stars. This suggests that flare frequency may be related to stellar age (younger stars are more likely to flare) and that the flare stars are younger than the mean active population.

79 ASTRONOMY AND ASTROPHYSICS↗

Photoinduced Melting of Superconductivity in the High-Tc Superconductor La2−xSrxCuO4 Probed by Time-resolved Optical and Terahertz Techniques

The dynamics of depletion and recovery of a superconducting state in La{sub 2-x}Sr{sub x}CuO{sub 4} thin films is investigated utilizing optical pump-probe and optical pump-THz-probe techniques as a function of temperature and excitation fluence. The absorbed energy density required to suppress superconductivity is found to be about eight times higher than the thermodynamically determined condensation energy density and nearly temperature independent between 4 and 25 K. These findings indicate that, during the time when the superconducting state suppression takes place ({approx}0.7 ps), a large part (nearly 90%) of the energy is transferred to the phonons with energy lower than twice the maximum value of the superconducting gap and only 10% is spent on Cooper pair breaking.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗