Search NASA⌕ Search

SEARCH · Search NASA

Results for “timing error evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

New constraint on the Np 237 ( n , γ ) Np 238 integral cross section using the Godiva-IV critical assembly

Accurate knowledge of the 237 Np(n, γ) 238 Np cross section at fast neutron energies is important for applied nuclear science. The presently available experimental data has large disagreements in the fast neutron region. Perform a model-independent measurement of the 237 Np(n, γ) 238 Np integral cross section using a well characterized fast neutron source and compare the result with previous measurements and current nuclear data evaluations. Provide an integral measurement that can be used as a benchmark for current evaluations. Multiple samples of 237 Np were irradiated in the Godiva-IV critical assembly. Following the irradiation, the samples placed in a γ-ray counting setup and the γ-rays emitted from the decay of 238 Np were measured over a time period of approximately 7 days. Multiple γ-ray decay branches of 238 Np were observed. The observed activity of 238 Np was used to calculate the amount of 238 Np produced during the irradiation via the 237 Np(n, γ) 238 Np reaction and an integral cross section of 342(11) mb was measured for the Godiva-IV neutron spectrum. Further, the 238 Np half-life has been measured with a result of 50.31(5) hours. The 237 Np(n, γ) 238 Np integral cross section measured in this work is in agreement with overlapping 1σ error bands to ENDF/B-VIII.0. However, the measured value is 3σ away from the calculated integral cross section using JENDL-5. This measurement offers a reliable benchmark for future 237 Np(n, γ) 238 Np cross section evaluations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The New Sun-Sky-Lunar Cimel CE318-T Multiband Photometer - A Comprehensive Performance Evaluation

This paper presents the new photometer CE318-T, able to perform daytime and night-time photometric measurements using the sun and the moon as light source. Therefore,this new device permits a complete cycle of diurnal aerosol and water vapour measurements valuable to enhance atmospheric monitoring to be extracted. In this study wehave found significantly higher precision of triplets when comparing the CE318-T master instrument and the Cimel AErosol RObotic NET work (AERONET) master (CE318-AERONET) triplets as a result of the new CE318-T tracking system. Regarding the instrument calibration, two new methodologies to transfer the calibration from a reference instrument using only daytime measurements (Sun Ratio and Sun-Moon gain factor techniques) are presented and discussed. These methods allow the reduction of the previous complexities inherent to nocturnal calibration. A quantitative estimation of CE318-T AOD uncertainty by means of error propagation theory during daytime revealed AOD uncertainties (u(sup D)(sub AOD)) for Langley-calibrated instruments similar to the expected values for other reference instruments (0.002-0.009). We have also found u(sup D)(sub AOD) values similar to the values reported in sun photometry for field instruments (approximately 0.015). In the case of the night-time period, the CE318-T-estimated standard combined uncertainty (u(sup N)(sub AOD)) is dependent not only on the calibration technique but also on illumination conditions and the instrumental noise. These values range from 0.011-0.018 for Lunar Langley-calibrated instruments to 0.012-0.021 for instruments calibrated using the Sun Ratio technique. In the case of moon-calibrated instruments using the Sun-Moon gain factor method and sun calibrated using the Langley technique, we found u(sup N)(sub AOD) ranging from 0.016 to 0.017 (up to 0.019 in 440 nm channel), not dependent on any lunar irradiance model. A subsequent performance evaluation including CE318-T and collocated measurements from independent reference instruments has served to assess the CE318-T performance as well as to confirm its estimated uncertainty. Daytime AOD evaluation, performed at Izana station from March to June 2014, encompassed measurements from a reference CE318-T, a CE318-AERONET master instrument, a Precision Filter Radiometer (PFR) and a Precision Spectroradiometer (PSR) prototype, reporting low AOD discrepancies between the four instruments (up to 0.006). The nocturnal AOD evaluation was performed using CE318-T- and starphotometer-collocated measurements and also by means of a day/night coherence transition test using the CE318-T master instrument and the CE318 daytime data from the CE318-AERONET master instrument. Results showed low discrepancies with the star photometer at 870 and 500 nm channels(less tna or equal to 0.013) and differences with AERONET daytime data (1 h after and before sunset and sunrise) in agreement with the estimated u(sup N)(sub AOD) values at all illumination conditions in the case of channels within the visible spectral range, and only for high moon's illumination conditions in the case of near infrared channels. Perceptible water vapour (PWV) validation showed a good agreement between CE318-T and Global Navigation Satellite System (GNSS) PWV values for all illumination conditions, within the expected precision for sun photometry. Finally, two case studies have been included to highlight the ability of the new CE318-T to capture the diurnal cycle of aerosols and water vapour as well as short-term atmospheric variations, critical for climate studies.

Barreto, Africa↗

Cosmology intertwined: A review of the particle physics, astrophysics, and cosmology associated with the cosmological tensions and anomalies

The standard Λ Cold Dark Matter (ΛCDM) cosmological model provides a good description of a wide range of astrophysical and cosmological data. However, there are a few big open questions that make the standard model look like an approximation to a more realistic scenario yet to be found. In this paper, we list a few important goals that need to be addressed in the next decade, taking into account the current discordances between the different cosmological probes, such as the disagreement in the value of the Hubble constant H 0 , the σ 8 – S 8 tension, and other less statistically significant anomalies. While these discordances can still be in part the result of systematic errors, their persistence after several years of accurate analysis strongly hints at cracks in the standard cosmological scenario and the necessity for new physics or generalisations beyond the standard model. In this paper, we focus on the 5.0 σ tension between the Planck CMB estimate of the Hubble constant H 0 and the SH0ES collaboration measurements. After showing the H 0 evaluations made from different teams using different methods and geometric calibrations, we list a few interesting new physics models that could alleviate this tension and discuss how the next decade's experiments will be crucial. Moreover, we focus on the tension of the Planck CMB data with weak lensing measurements and redshift surveys, about the value of the matter energy density Ω m , and the amplitude or rate of the growth of structure ( σ 8 , f σ 8 ). We list a few interesting models proposed for alleviating this tension, and we discuss the importance of trying to fit a full array of data with a single model and not just one parameter at a time. Additionally, we present a wide range of other less discussed anomalies at a statistical significance level lower than the H 0 – S 8 tensions which may also constitute hints towards new physics, and we discuss possible generic theoretical approaches that can collectively explain the non-standard nature of these signals. Finally, we give an overview of upgraded experiments and next-generation space missions and facilities on Earth that will be of crucial importance to address all these open questions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Unraveling the 2021 Central Tennessee flood event using a hierarchical multi-model inundation modeling framework

Flood prediction systems need hierarchical atmospheric, hydrologic, and hydraulic models to predict rainfall, runoff, streamflow, and floodplain inundation. The accuracy of such systems depends on the error propagation through the modeling chain, sensitivity to input data, and choice of models. In this study, we used multiple precipitation forcings (hindcast and forecast) to drive hydrologic and hydrodynamic models to analyze the impacts of various drivers on the estimates of flood inundation depth and extent. We implement this framework to unravel the August 2021 extreme flooding event that occurred in Central Tennessee, USA. We used two radar-based quantitative precipitation estimates (STAGE4 and MRMS) as well as quantitative precipitation forecasts (QPF) from the National Weather Service Weather Prediction Center (WPC) to drive a series of models in the hierarchical framework, including the Variable Infiltration Capacity (VIC) land surface model, the Routing Application for Parallel Computation of Discharge (RAPID) river routing model, and the AutoRoute and TRITON inundation models. An evaluation with observed high-water marks demonstrates that the framework can reasonably simulate flood inundation. Despite the complex error propagation mechanism of the modeling chain, we show that inundation estimates are most sensitive to rainfall estimates. Most notably, QPF significantly underestimates flood magnitudes and inundations leading to unanticipated severe flooding for all stakeholders involved in the event. Finally, we discuss the implications of the hydrodynamic modeling framework for real-time flood forecasting.

54 ENVIRONMENTAL SCIENCES↗

SU-G-JeP4-02: An Investigation of Respiratory Surrogate Motion Data Requirements for Multiple-Step Ahead Prediction

Purpose: Respiratory-gated radiotherapy and dynamic tracking employ real-time imaging and surrogate motion-monitoring methods with tumor motion prediction in advance of real-time. This study investigated respiratory motion data length on prediction accuracy of tumor motion. Methods: Predictions generated from the algorithm are validated against a one-dimensional surrogate signal of amplitude versus time. Prediction consists of three major components: extracting top-ranked subcomponents from training data matching the last respiratory cycle; calculating weighting factors from best-matched subcomponents; fusing data proceeding best-matched subcomponents with respective weighting factors to form predictions. Predictions for one respiratory cycle (∼3-6seconds) were assessed using 351 patient data from the respiratory management device. Performance was evaluated for correlation coefficient and root mean square error (RMSE) between prediction and final respiratory cycle. Results: Respiratory prediction results fell into two classes, where best predictions for 70 cycles or less performed using relative prediction and greater than 70 cycles are predicted similarly using relative and derivative relative. For 70 respiratory cycles or less, the average correlation between prediction and final respiratory cycle was 0.9999±0.0001, 0.9999±0.0001, 0.9988±0.0003, 0.9985±0.0023, and 0.9981±0.0023 with RMSE values of 0.0091±0.0030, 0.0091±0.0030, 0.0305±0.0051, 0.0299±0.0259, and 0.0299±0.0259 for equal, relative, pattern, derivative equal and derivative relative weighting methods, respectively. Respectively, the total best prediction for each method was 37, 65, 20, 22, and 22. For data with greater than 70 cycles average correlation was 0.9999±0.0001, 0.9999±0.0001, 0.9988±0.0004, 0.9988±0.0020, and 0.9988±0.0020 with RMSE values of 0.0081±0.0031, 0.0082±0.0033, 0.0306±0.0056, 0.0218±0.0222, and 0.0218±0.0222 for equal, relative, pattern, derivative equal and derivative relative weighting methods, respectively. Respectively, the total best prediction for each method was 24, 44, 42, 30, and 45. Conclusion: The prediction algorithms are effective in estimating surrogate motion in advance. These results indicate an advantage in using relative prediction for shorter data and either relative or derivative relative prediction for longer data.

60 APPLIED LIFE SCIENCES↗

Determining Reduced Order Models for Optimal Stochastic Reduced Order Models

The use of parameterized reduced order models(PROMs) within the stochastic reduced order model (SROM) framework is a logical progression for both methods. In this report, five different parameterized reduced order models are selected and critiqued against the other models along with truth model for the example of the Brake-Reuss beam. The models are: a Taylor series using finite difference, a proper orthogonal decomposition of the the output, a Craig-Bampton representation of the model, a method that uses Hyper-Dual numbers to determine the sensitivities, and a Meta-Model method that uses the Hyper-Dual results and constructs a polynomial curve to better represent the output data. The methods are compared against a parameter sweep and a distribution propagation where the first four statistical moments are used as a comparison. Each method produces very accurate results with the Craig-Bampton reduction having the least accurate results. The models are also compared based on time requirements for the evaluation of each model where the Meta- Model requires the least amount of time for computation by a significant amount. Each of the five models provided accurate results in a reasonable time frame. The determination of which model to use is dependent on the availability of the high-fidelity model and how many evaluations can be performed. Analysis of the output distribution is examined by using a large Monte-Carlo simulation along with a reduced simulation using Latin Hypercube and the stochastic reduced order model sampling technique. Both techniques produced accurate results. The stochastic reduced order modeling technique produced less error when compared to an exhaustive sampling for the majority of methods.

97 MATHEMATICS AND COMPUTING↗

BATSE Observations of the Piccinotti Sample of AGN II: Variability and Spectral Analysis

The Piccinotti sample is the hard x-ray-selected sample of active galactic nuclei (AGNs) best studied at energies below approximately 10 keV. It represents the only unbiased and complete high-energy survey of the sky down to a limiting flux of 3.1 x 10(exp -11) per square erg per second. As such, it has been used to study AGN properties such as X-ray spectral characteristics, log N-log S relation, and luminosity function. The BATSE data provide, for the first time, a systematic coverage of the whole sample at high energies. BATSE data from nearly four years of observations (1993 November - 1997 September) were analyzed using standard BATSE occultation analysis software to extract a signal from sources in the Piccinotti sample. Although the BATSE sensitivity for individual source measurements is relatively poor on short time scales, the near all-sky coverage and long CGRO lifetime allows us to improve our sensitivity considerably by sumrr~ng data over many years. This significantly reduces our statistical errors at the expense of loss of temporal information. However, the systematic errors associated with the summation of data over such a long period are not negligible, and the study of systematic effects was a major part of our effort. We evaluated two types of systematic error: those affecting the overall normalization (which are important for comparison with other instruments) and those affecting the size of the fluctuations (which are relevant for estimating the confidence level of a detection). The former was studied by comparison of BATSE data with other instruments, primarily CGRO/OSSE. The results indicate that our absolute flux values maybe overestimated by as much as 35% for some sources. However, since this does not affect our estimation of the detection confidence, we made no corrections to our flux estimates.

Paciesas, William S.↗

Time-on-task decrements in "steer clear" performance of patients with sleep apnea and narcolepsy

Loss of attention with time-on-task reflects the increasing instability of the waking state during performance in experimentally induced sleepiness. To determine whether patients with disorders of excessive sleepiness also displayed time-on-task decrements indicative of wake state instability, visual sustained attention performance on "Steer Clear," a computerized simple RT driving simulation task, was compared among 31 patients with untreated sleep apnea, 16 patients with narcolepsy, and 14 healthy control subjects. Vigilance decrement functions were generated by analyzing the number of collisions in each of six four-minute periods of Steer Clear task performance in a mixed-model analysis of variance and linear regression equations. As expected, patients had more Steer Clear collisions than control subjects (p=0.006). However, the inter-subject variability in errors among the narcoleptic patients was four-fold that of the apnea patients, and 100-fold that of the controls volunteers; the variance in errors among untreated apnea patients was 27-times that of controls. The results of transformed collision data revealed main effects for group (p=0.006), time-on-task (p=0.001), and a significant interaction (p=0.022). Control subjects showed no clear evidence of increasing collision errors with time-on-task (adjusted R2=0.22), while apnea patients showed a trend toward vigilance decrement (adjusted R2=0.42, p=0.097), and narcolepsy patients evidenced a robust linear vigilance decrement (adjusted R2=0.87, p=0.004). The association of disorders of excessive somnolence with escalating time-on-task decrements makes it imperative that when assessment of neurobehavioral performance is conducted in patients, it involves task durations and analyses that will evaluate the underlying vulnerability of potentially sleepy patients to decrements over time in tasks that require sustained attention and timely responses, both of which are key components in safe driving performance.

NASA Discipline Space Human Factors↗

Best Practices of Uncertainty Estimation for the National Solar Radiation Database (NSRDB 1998-2015): Preprint

It is essential to apply a traceable and standard approach to determine the uncertainty of solar resource data. Solar resource data are used for all phases of solar energy conversion projects, from the conceptual phase to routine solar power plant operation, and to determine performance guarantees of solar energy conversion systems. These guarantees are based on the available solar resource derived from a measurement station or modeled data set such as the National Solar Radiation Database (NSRDB). Therefore, quantifying the uncertainty of these data sets provides confidence to financiers, developers, and site operators of solar energy conversion systems and ultimately reduces deployment costs. In this study, we implemented the Guide to the Expression of Uncertainty in Measurement (GUM) 1 to quantify the overall uncertainty of the NSRDB data. First, we start with quantifying measurement uncertainty, then we determine each uncertainty statistic of the NSRDB data, and we combine them using the root-sum-of-the-squares method. The statistics were derived by comparing the NSRDB data to the seven measurement stations from the National Oceanic and Atmospheric Administration's Surface Radiation Budget Network, National Renewable Energy Laboratory's Solar Radiation Research Laboratory, and the Atmospheric Radiation Measurement program's Southern Great Plains Central Facility, in Billings, Oklahoma. The evaluation was conducted for hourly values, daily totals, monthly mean daily totals, and annual mean monthly mean daily totals. Varying time averages assist to capture the temporal uncertainty of the specific modeled solar resource data required for each phase of a solar energy project; some phases require higher temporal resolution than others. Overall, by including the uncertainty of measurements of solar radiation made at ground stations, bias, and root mean square error, the NSRDB data demonstrated expanded uncertainty of 17 percent - 29 percent on hourly and an approximate 5 percent - 8 percent annual bases.

14 SOLAR ENERGY↗

An improved method for direct incident solar radiation calculation from hourly solar insolation data in building energy simulation

Solar radiation considerably influences the energy consumption of buildings and the power production of building integrated photovoltaic (BIPV) systems. Hourly solar insolation (Wh/m 2 ), represented as the amount of solar irradiance collected on the ground during a 1-h period, is the most common solar radiation data available and widely used in weather files applied in building energy modeling programs (BEMPs). Because the solar beam and position vary over time, the use of hourly insolation data as the input might result in errors in the estimation of the direct incident solar radiation on a particular surface. In this study, methods used in BEMPs for direct incident solar radiation calculations are first analyzed, and an improved method adopting a new algorithm for estimating the solar irradiance is proposed. Furthermore, the algorithm assumes that the solar irradiance changes linearly within a 1-h period and can be estimated based on the solar irradiance at the half clock and slope. The collected direct normal solar irradiance data of 2016 from eight solar radiation stations in China were used to demonstrate the proposed method and evaluate its performance by comparing the results with those from three conventional methods used in BEMPs along with the ground truth measurements. In addition, in this study, factors affecting the accuracy of the calculation results are explored. The results of the estimated direct incident solar radiation show that the proposed method achieves the best accuracy, followed by the methods used in DOE-2, EnergyPlus, and DeST. The proposed method guarantees that the hourly direct solar insolation will remain the same and reflects the variation in the direct solar irradiance across a 1-h time frame. The proposed method can be adopted in BEMPs to improve the accuracy of the solar radiation calculation, thereby improving the accuracy of the simulated building performance and the BIPV production.

14 SOLAR ENERGY↗

NR sulphur vulcanization: Interaction study between TBBS and DPG by means of a combined experimental rheometer and meta-model best fitting strategy

The paper is aimed at studying the possible interaction between two different accelerators (DPG and TBBS) in the chemical kinetic of Natural Rubber (NR) vulcanized with sulphur. The same blend with several DPG and TBBS concentrations is deeply analyzed from an experimental point of view, varying the curing temperature in the range 150-180°C and obtaining rheometer curves with a step of 10°C. In order to study any possible interaction between the two accelerators –and eventually evaluating its engineering relevance-rheometer data are normalized by means of the well known Sun and Isayev normalization approach and two output parameters are assumed as meaningful to have an insight into the possible interaction, namely time at maximum torque and reversion percentage. Two different numerical meta-models, which belong to the family of the so-called response surfaces RS are compared. The first is linear against TBBS and DPG and therefore well reproduces no interaction between the accelerators, whereas the latter is a non-linear RS with bilinear term. Both RS are deduced from standard best fitting of experimental data available. It is found that, generally, there is a sort of interaction between TBBS and DPG, but that the error introduced making use of a linear model (no interaction) is generally lower than 10%, i.e. fully acceptable from an engineering standpoint.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Results of Propellant Mixing Variable Study Using Precise Pressure-Based Burn Rate Calculations

A designed experiment was conducted in which three mix processing variables (pre-curative addition mix temperature, pre-curative addition mixing time, and mixer speed) were varied to estimate their effects on within-mix propellant burn rate variability. The chosen discriminator for the experiment was the 2-inch diameter by 4-inch long (2x4) Center-Perforated (CP) ballistic evaluation motor. Motor nozzle throat diameters were sized to produce a common targeted chamber pressure. Initial data analysis did not show a statistically significant effect. Because propellant burn rate must be directly related to chamber pressure, a method was developed that showed statistically significant effects on chamber pressure (either maximum or average) by adjustments to the process settings. Burn rates were calculated from chamber pressures and these were then normalized to a common pressure for comparative purposes. The pressure-based method of burn rate determination showed significant reduction in error when compared to results obtained from the Brooks' modification of the propellant web-bisector burn rate determination method. Analysis of effects using burn rates calculated by the pressure-based method showed a significant correlation of within-mix burn rate dispersion to mixing duration and the quadratic of mixing duration. The findings were confirmed in a series of mixes that examined the effects of mixing time on burn rate variation, which yielded the same results.

Stefanski, Philip L.↗

SU-E-J-12: An Image-Guided Soft Robotic Patient Positioning System for Maskless Head-And-Neck Cancer Radiotherapy: A Proof-Of-Concept Study

Purpose: We propose a surface-image-guided soft robotic patient positioning system for maskless head-and-neck radiotherapy. The ultimate goal of this project is to utilize a soft robot to realize non-rigid patient positioning and real-time motion compensation. In this proof-of-concept study, we design a position-based visual servoing control system for an air-bladder-based soft robot and investigate its performance in controlling the flexion/extension cranial motion on a mannequin head phantom. Methods: The current system consists of Microsoft Kinect depth camera, an inflatable air bladder (IAB), pressured air source, pneumatic valve actuators, custom-built current regulators, and a National Instruments myRIO microcontroller. The performance of the designed system was evaluated on a mannequin head, with a ball joint fixed below its neck to simulate torso-induced head motion along flexion/extension direction. The IAB is placed beneath the mannequin head. The Kinect camera captures images of the mannequin head, extracts the face, and measures the position of the head relative to the camera. This distance is sent to the myRIO, which runs control algorithms and sends actuation commands to the valves, inflating and deflating the IAB to induce head motion. Results: For a step input, i.e. regulation of the head to a constant displacement, the maximum error was a 6% overshoot, which the system then reduces to 0% steady-state error. In this initial investigation, the settling time to reach the regulated position was approximately 8 seconds, with 2 seconds of delay between the command start of motion due to capacitance of the pneumatics, for a total of 10 seconds to regulate the error. Conclusion: The surface image-guided soft robotic patient positioning system can achieve accurate mannequin head flexion/extension motion. Given this promising initial Result, the extension of the current one-dimensional soft robot control to multiple IABs for non-rigid positioning control will be pursued.

60 APPLIED LIFE SCIENCES↗

THE APPLICATION OF CONTINUOUS WAVELET TRANSFORM BASED FOREGROUND SUBTRACTION METHOD IN 21 cm SKY SURVEYS

We propose a continuous wavelet transform based non-parametric foreground subtraction method for the detection of redshifted 21 cm signal from the epoch of reionization. This method works based on the assumption that the foreground spectra are smooth in frequency domain, while the 21 cm signal spectrum is full of saw-tooth-like structures, thus their characteristic scales are significantly different. We can distinguish them in the wavelet coefficient space easily and perform the foreground subtraction. Compared with the traditional spectral fitting based method, our method is more tolerant to complex foregrounds. Furthermore, we also find that when the instrument has uncorrected response error, our method can also work significantly better than the spectral fitting based method. Our method can obtain similar results with the Wp smoothing method, which is also a non-parametric method, but our method consumes much less computing time.

79 ASTRONOMY AND ASTROPHYSICS↗

TH-CD-209-02: Beam Angle Optimization Incorporating Anatomical Heterogeneities for Pencil Beam Scanning Charged-Particle Therapy

Purpose: In charged particle therapy with pencil beam scanning (PBS), localization of the dose in the Bragg peak makes dose distributions sensitive to lateral tissue heterogeneities. Sensitivity of a PBS plan to lateral tissue heterogeneity can be reduced by selecting suitable beam angles. The purpose of this study is to establish a fast and accurate method of beam angle selection for PBS. Methods: The lateral tissue heterogeneity surrounding the path of respective pencil beams at a given angle was quantified with the heterogeneity number using effective density data of patients. To shorten the computation time, one dimensional dose calculation and optimization were conducted along the central axis of pencil beams originating from the scanning magnets. Calculation was performed for all fields with possible gantry and couch angles. The angles leading the minimum mean heterogeneity number was selected as the optimal beam angle. Three head and neck (H&N) cancer patients were used to evaluate our method. Dose distributions and their robustness to range and set up errors were evaluated for all tested angles, and their relation to their heterogeneity numbers were investigated. Results: Variety of heterogeneity number was clearly shown due to air cavities and bony structures in the patients. The mean value of heterogeneity number in all possible fields varied between 1.2 and 10.6 mm. By selecting a field with a lower mean value of heterogeneity number, target dose coverage and robustness of the fields were improved. Conclusion: We developed a computational method to determine a beam angle that leads good target coverage and robustness to setup errors. The developed stand-alone computation program is simple, fast, accurate and applicable for beam angle selection in PBS therapy.

60 APPLIED LIFE SCIENCES↗

Consistent evaluation of GOSAT, SCIAMACHY, carbontracker, and MACC through comparisons to TCCON

Consistent validation of satellite CO 2 estimates is a prerequisite for using multiple satellite CO 2 measurements for joint flux inversion, and for establishing an accurate long-term atmospheric CO 2 data record. We focus on validating model and satellite observation attributes that impact flux estimates and CO 2 assimilation, including accurate error estimates, correlated and random errors, overall biases, biases by season and latitude, the impact of coincidence criteria, validation of seasonal cycle phase and amplitude, yearly growth, and daily variability. We evaluate dry air mole fraction (X CO 2 ) for GOSAT (ACOS b3.5) and SCIAMACHY (BESD v2.00.08) as well as the CarbonTracker (CT2013b) simulated CO 2 mole fraction fields and the MACC CO 2 inversion system (v13.1) and compare these to TCCON observations (GGG2014). We find standard deviations of 0.9 ppm, 0.9, 1.7, and 2.1 ppm versus TCCON for CT2013b, MACC, GOSAT, and SCIAMACHY, respectively, with the single target errors 1.9 and 0.9 times the predicted errors for GOSAT and SCIAMACHY, respectively. When satellite data are averaged and interpreted according to error 2 = a 2 + b 2 / n (where n are the number of observations averaged, a are the systematic (correlated) errors, and b are the random (uncorrelated) errors), we find that the correlated error term a = 0.6 ppm and the uncorrelated error term b = 1.7 ppm for GOSAT and a = 1.0 ppm, b = 1.4 ppm for SCIAMACHY regional averages. Biases at individual stations have year-to-year variability of ~ 0.3 ppm, with biases larger than the TCCON predicted bias uncertainty of 0.4 ppm at many stations. Using fitting software, we find that GOSAT underpredicts the seasonal cycle amplitude in the Northern Hemisphere (NH) between 46–53° N. In the Southern Hemisphere (SH), CT2013b underestimates the seasonal cycle amplitude. Biases are calculated for 3-month intervals and indicate the months that contribute to the observed amplitude differences. The seasonal cycle phase indicates whether a dataset or model lags another dataset in time. We calculate this at a subset of stations where there is adequate satellite data, and find that the GOSAT retrieved phase improves substantially over the prior and the SCIAMACHY retrieved phase improves substantially for 2 of 7 sites. The models reproduce the measured seasonal cycle phase well except for at Lauder125 (CT2013b), Darwin (MACC), and Izana (+ 10 days, CT2013b), as for Bremen and Four Corners, which are highly influenced by local effects. We compare the variability within one day between TCCON and models in JJA; there is correlation between 0.2 and 0.8 in the NH, with models showing 10–100 % the variability of TCCON at different stations (except Bremen and Four Corners which have no variability compared to TCCON) and CT2013b showing more variability than MACC. This paper highlights findings that provide inputs to estimate flux errors in model assimilations, and places where models and satellites need further investigation, e.g. the SH for models and 45–67° N for GOSAT

54 ENVIRONMENTAL SCIENCES↗

Operational support for Upper Atmosphere Research Satellite (UARS) attitude sensors

The Upper Atmosphere Research Satellite (UARS) has several sensors that can provide observations for attitude determination: star trackers, Sun sensors (gimbaled as well as fixed), magnetometers, Earth sensors, and gyroscopes. The accuracy of these observations is important for mission success. Analysts on the Flight Dynamics Facility (FDF) UARS Attitude task monitor these data to evaluate the performance of the sensors taking corrective action when appropriate. Monitoring activities range from examining the data during real-time passes to constructing long-term trend plots. Increasing residuals (differences) between the observed and expected quantities is a prime indicator of sensor problems. Residual increases may be due to alignment shifts and/or degradation in sensor output. Residuals from star tracker data revealed and anomalous behavior that contributes to attitude errors. Compensating for this behavior has significantly reduced the attitude errors. This paper discusses the methods used by the FDF UARS attitude task for maintenance of the attitude sensors, including short- and long-term monitoring, trend analysis, and calibration methods, and presents the results obtained through corrective action.

Lee, M.↗

Dynamics of a split torque helicopter transmission

Split torque designs, proposed as alternatives to traditional planetary designs for helicopter main rotor transmissions, can save weight and be more reliable than traditional designs. This report presents the results of an analytical study of the system dynamics and performance of a split torque gearbox that uses a balance beam mechanism for load sharing. The Lagrange method was applied to develop a system of equations of motion. The mathematical model includes time-varying gear mesh stiffness, friction, and manufacturing errors. Cornell's method for calculating the stiffness of spur gear teeth was extended and applied to helical gears. The phenomenon of sidebands spaced at shaft frequencies about gear mesh fundamental frequencies was simulated by modeling total composite gear errors as sinusoid functions. Although the gearbox has symmetric geometry, the loads and motions of the two power paths differ. Friction must be considered to properly evaluate the balance beam mechanism. For the design studied, the balance beam is not an effective device for load sharing unless the coefficient of friction is less than 0.003. The complete system stiffness as represented by the stiffness matrix used in this analysis must be considered to precisely determine the optimal tooth indexing position.

Krantz, Timothy L.↗