Search NASA⌕ Search

SEARCH · Search NASA

Results for “volume estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Silurian "Clinton" Sandstone Reservoir Characterization for Evaluation of CO2-EOR Potential in the East Canton Oil Field, Ohio

The purpose of this study was to evaluate the efficacy of using CO2-enhanced oil recovery (EOR) in the East Canton oil field (ECOF). Discovered in 1947, the ECOF in northeastern Ohio has produced approximately 95 million barrels (MMbbl) of oil from the Silurian 'Clinton' sandstone. The original oil-in-place (OOIP) for this field was approximately 1.5 billion bbl and this study estimates by modeling known reservoir parameters, that between 76 and 279 MMbbl of additional oil could be produced through secondary recovery in this field, depending on the fluid and formation response to CO2 injection. A CO2 cyclic test ('Huff-n-Puff') was conducted on a well in Stark County to test the injectivity in a 'Clinton'-producing oil well in the ECOF and estimate the dispersion or potential breakthrough of the CO2 to surrounding wells. Eighty-one tons of CO2 (1.39 MMCF) were injected over a 20-hour period, after which the well was shut in for a 32-day 'soak' period before production was resumed. Results demonstrated injection rates of 1.67 MMCF of gas per day, which was much higher than anticipated and no CO2 was detected in gas samples taken from eight immediately offsetting observation wells. All data collected during this test was analyzed, interpreted, and incorporated into the reservoir characterization study and used to develop the geologic model. The geologic model was used as input into a reservoir simulation performed by Fekete Associates, Inc., to estimate the behavior of reservoir fluids when large quantities of CO2 are injected into the 'Clinton' sandstone. Results strongly suggest that the majority of the injected CO2 entered the matrix porosity of the reservoir pay zones, where it diffused into the oil. Evidence includes: (A) the volume of injected CO2 greatly exceeded the estimated capacity of the hydraulic fracture and natural fractures; (B) there was a gradual injection and pressure rate build-up during the test; (C) there was a subsequent, gradual flashout of the CO2 within the reservoir during the ensuing monitored production period; and (D) a large amount of CO2 continually off-gassed from wellhead oil samples collected as late as 3 1/2 months after injection. After the test well was returned to production, it produced 174 bbl of oil during a 60-day period (September 22 to November 21, 2008), which represents an estimated 58 percent increase in incremental oil production over preinjection estimates of production under normal, conditions. The geologic model was used in a reservoir simulation model for a 700-acre model area and to design a pilot to test the model. The model was designed to achieve a 1-year response time and a five-year simulation period. The reservoir simulation modeling indicated that the injection wells could enhance oil production and lead to an additional 20 percent recovery in the pilot area over a five-year period. The base case estimated that by injecting 500 MCF per day of CO2 into each of the four corner wells, 26,000 STBO would be produced by the central producer over the five-year period. This would compare to 3,000 STBO if a new well were drilled without the benefit of CO2 injection. This study has added significant knowledge to the reservoir characterization of the 'Clinton' in the ECOF and succeeded in identifying a range on CO2-EOR potential. However, additional data on fluid properties (PVT and swelling test), fractures (oriented core and microseis), and reservoir characteristics (relative permeability, capillary pressure, and wet ability) are needed to further narrow the uncertainties and refine the reservoir model and simulation. After collection of this data and refinement of the model and simulation, it is recommended that a larger scale cyclic-CO2 injection test be conducted to better determine the efficacy of CO2-EOR in the 'Clinton' reservoir in the ECOF.

02 PETROLEUM↗

Fluid pressure arrival time tomography: Estimation and assessment in the presence of inequality constraints, with an application to a producing gas field at Krechba, Algeria

Deformation in the overburden proves useful in deducing spatial and temporal changes in the volume of a producing reservoir. Based upon these changes we estimate diffusive travel times associated with the transient flow due to production, and then, as the solution of a linear inverse problem, the effective permeability of the reservoir. An advantage an approach based upon travel times, as opposed to one based upon the amplitude of surface deformation, is that it is much less sensitive to the exact geomechanical properties of the reservoir and overburden. Inequalities constrain the inversion, under the assumption that the fluid production only results in pore volume decreases within the reservoir. We apply the formulation to satellite-based estimates of deformation in the material overlying a thin gas production zone at the Krechba field in Algeria. The peak displacement after three years of gas production is approximately 0.5 cm, overlying the eastern margin of the anticlinal structure defining the gas field. Using data from 15 irregularly-spaced images of range change, we calculate the diffusive travel times associated with the startup of a gas production well. The inequality constraints are incorporated into the estimates of model parameter resolution and covariance, improving the resolution by roughly 30 to 40%.

54 ENVIRONMENTAL SCIENCES↗

Validation of UARS Microwave Limb Sounder 183 GHz H2O Measurements

The Upper Atmosphere Research Satellite (UARS) microwave limb sounder (MLS) makes measurements of thermal emission at 183.3 GHz which are used to infer the concentration of water vapor over a pressure range of 46-0.2hPa (approximately 20-60 km). We provide a validation of MLS H2O by analyzing the integrity of the measurements, by providing an error characterization, and by comparison with data from other instruments. It is estimated that version 3 MLS H2O retrievals are accurate to within 20-25% in the lower stratosphere and to within 8-13% in the upper stratosphere and lower mesosphere. The precision of a single profile is estimated to be approximately 0.15 parts per million by volume (ppmv) in the midstratosphere and 0.2 ppmv in the lower and upper stratosphere. In the lower mesosphere the estimate of a single profile precision is 0.25-0.45 ppmv. During polar winter conditions, H2O retrievals at 46 hPa can have a substantial contribution from climatology. The vertical resolution of MLS H2O retrievals is approximately 5 km.

Lahoz, W. A.↗

Method for estimating the density of high-level nuclear waste glass

A database of over 1100 silicate glass compositions and densities was compiled and used to evaluate the efficacy of an algorithm for estimating the density of silicate glass compositions. We sought to develop a parsimonious algorithm based on the additivity of partial molar volumes of individual oxide components weighted by their mole fraction in a glass composition. Bound molar volumes were used for oxides in which the density of the oxide bound in a glass matrix was previously determined. The bound molar volumes were known for oxides covering 97.5 mole percent of the database compositional space. The measured glass densities were plotted against the estimated glass densities and a linear regression yielded an R 2 adj. = 0.95 and a slope and intercept of approximately one and zero, respectively. This regression suggests that glass densities estimated by the algorithm, within analysis uncertainty, are equal to the measured densities of the glasses. In addition to the development of the density estimation, we corroborated many of the referenced bound molar volume data used in the parameterization of the estimation algorithm via linear regression of the individual partial molar volumes versus the inverse measured densities (specific volumes) of the glasses in the database.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High-Grade Glioma Radiation Therapy Target Volumes and Patterns of Failure Obtained From Magnetic Resonance Imaging and {sup 18}F-FDOPA Positron Emission Tomography Delineations From Multiple Observers

Purpose: The objective of this study was to compare recurrent tumor locations after radiation therapy with pretreatment delineations of high-grade gliomas from magnetic resonance imaging (MRI) and 3,4-dihydroxy-6-[{sup 18}F]fluoro-L-phenylalanine ({sup 18}F-FDOPA) positron emission tomography (PET) using contours delineated by multiple observers. Methods and Materials: Nineteen patients with newly diagnosed high-grade gliomas underwent computed tomography (CT), gadolinium contrast-enhanced MRI, and {sup 18}F-FDOPA PET/CT. The image sets (CT, MRI, and PET/CT) were registered, and 5 observers contoured gross tumor volumes (GTVs) using MRI and PET. Consensus contours were obtained by simultaneous truth and performance level estimation (STAPLE). Interobserver variability was quantified by the percentage of volume overlap. Recurrent tumor locations after radiation therapy were contoured by each observer using CT or MRI. Consensus recurrence contours were obtained with STAPLE. Results: The mean interobserver volume overlap for PET GTVs (42% ± 22%) and MRI GTVs (41% ± 22%) was not significantly different (P=.67). The mean consensus volume was significantly larger for PET GTVs (58.6 ± 52.4 cm{sup 3}) than for MRI GTVs (30.8 ± 26.0 cm{sup 3}, P=.003). More than 95% of the consensus recurrence volume was within the 95% isodose surface for 11 of 12 (92%) cases with recurrent tumor imaging. Ten (91%) of these cases extended beyond the PET GTV, and 9 (82%) were contained within a 2-cm margin on the MRI GTV. One recurrence (8%) was located outside the 95% isodose surface. Conclusions: High-grade glioma contours obtained with {sup 18}F-FDOPA PET had similar interobserver agreement to volumes obtained with MRI. Although PET-based consensus target volumes were larger than MRI-based volumes, treatment planning using PET-based volumes may not have yielded better treatment outcomes, given that all but 1 recurrence extended beyond the PET GTV and most were contained by a 2-cm margin on the MRI GTV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Final Geometry and Dimensions of UCG Field Test Cavities

This report documents parameters of underground coal gasification (UCG) field tests, coal seam geometries, and final documented dimensions of gasified coal cavities. Most of the analysis focused on Hanna, Hoe Creek, and Rocky Mountain. Other field tests are included, although thorough documentation was not done. Data and images are taken from multiple sources including field test reports, conference proceedings, presentations, and discussions. Time was restricted so not all data was included or researched. With time restricting, the main parameters of focus include maximum cavity length, maximum cavity width, coal zone height, maximum coal cavity height, oxidant at the end of the test, and shoebox dimensions (box width, length, and height dimensions such that the volume is approximately equal to that of the gasified cavity estimated from field test diagrams). The next important set of parameters include module type, well spacing, volume of consumed coal, volume of collapsed overburden, maximum cavity height, and duration of the test. The information of this report is meant to reflect on the final coal cavity geometries after days of forward gasification. In some cases, intermediate phases were not analyzed, especially if they consumed the same coal seam as later test phases.

01 COAL, LIGNITE, AND PEAT↗

Anomalous solute transport in saturated porous media: Relating transport model parameters to electrical and nuclear magnetic resonance properties

Abstract The advection‐dispersion equation (ADE) fails to describe commonly observed non‐Fickian solute transport in saturated porous media, necessitating the use of other models such as the dual‐domain mass‐transfer (DDMT) model. DDMT model parameters are commonly calibrated via curve fitting, providing little insight into the relation between effective parameters and physical properties of the medium. There is a clear need for material characterization techniques that can provide insight into the geometry and connectedness of pore spaces related to transport model parameters. Here, we consider proton nuclear magnetic resonance (NMR), direct‐current (DC) resistivity, and complex conductivity (CC) measurements for this purpose, and assess these methods using glass beads as a control and two different samples of the zeolite clinoptilolite, a material that demonstrates non‐Fickian transport due to intragranular porosity. We estimate DDMT parameters via calibration of a transport model to column‐scale solute tracer tests, and compare NMR, DC resistivity, CC results, which reveal that grain size alone does not control transport properties and measured geophysical parameters; rather, volume and arrangement of the pore space play important roles. NMR cannot provide estimates of more‐mobile and less‐mobile pore volumes in the absence of tracer tests because these estimates depend critically on the selection of a material‐dependent and flow‐dependent cutoff time. Increased electrical connectedness from DC resistivity measurements are associated with greater mobile pore space determined from transport model calibration. CC was hypothesized to be related to length scales of mass transfer, but the CC response is unrelated to DDMT.

Swanson, Ryan D.↗

Evolution of systems concepts for a 100 kWe class Space Nuclear Power System

Conceptual designs for the SP-100 Space Nuclear Power System have been prepared that meet baseline, backup and growth program scenarios. Near-term advancement in technology was considered in the design of the Baseline Concept. An improved silicon-germanium thermoelectric technique is used to convert the heat from a fast-spectrum, liquid lithium cooled reactor. This system produces a net power of 100 kWe with a 10-year end of life, under the specific constraints of area and volume. Output of the Backup Concept is estimated to be 60 kWe for a 10-year end of life. This system differs from the Baseline Concept because currently available thermoelectric conversion is used from energy supplied by a liquid sodium cooled reactor. The Growth Concept uses Stirling engine conversion to produce 100 kWe within the constraints of mass and volume. The Growth Concept can be scaled up to produce a 1 MWe output that uses the same type reactor developed for the Baseline Concept. Assessments made for each of the program scenarios indicate the key development efforts needed to initiate detailed design and hardware program phases. Development plans were prepared for each scenario that detail the work elements and show the program activities leading to a state of flight readiness.

Katucki, R.↗

Food consumption and digestion time estimation of spotted scat, Scatophagus argus, using X-radiography technique

The present study was conducted to investigate the food consumption pattern and gastric emptying time using x-radiography technique in scats fish, Scatophagus argus feeding to satiation in laboratory conditions. Prior to feeding experiment, fish of various sizes were examined their stomach volume, using freshly prepared stomachs ligatured at the tips of the burret, where the maximum amount of distilled water collected in the stomach were measured (ml). Stomach volume is correlated with maximum food intake (S{sub max}) and it can estimate the maximum stomach distension by allometric model i.e volume=0.0000089W{sup 2.93}. Gastric emptying time was estimated using a qualitative X-radiography technique, where the fish of various sizes were fed to satiation at different time since feeding. All the experimental fish was feed into satiation using radio-opaque barium sulphate (BaSO{sub 4}) paste injected in the wet shrimp in proportion to the body weight. The BaSO{sub 4} was found suitable to track the movement of feed/prey in the stomach over time and gastric emptying time of scats fish can be estimated. The results of qualitative X-Radiography observation of gastric motility, showed the fish (200 gm) that fed to maximum satiation meal (circa 11 gm) completely emptied their stomach within 30 - 36 hrs. The results of the present study will provide the first baseline information on the stomach volume, gastric emptying of scats fish in captivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transition Path Sampling of Water Exchange Rates and Mechanisms around Aqueous Ions

The rates and mechanisms of water exchange around two aqueous ions, namely, Na + and Fe 2+ , have been determined using transition path sampling. In particular, the pressure dependence of the water exchange rates was computed to determine activation volumes. A common approach for calculating water exchange rates, the reactive flux method, was also employed and the two methods were compared. The water exchange rate around Na + is fast enough to be calculated by direct molecular dynamics simulations, thus providing a reference for comparison. The transition path sampling approach yielded more accurate rates, although both approaches predicted activation volumes of +2.6 cm3·mol-1, in agreement with the direct simulation results. The only previously determined activation volume for Na + is from a theoretical estimation (Spångberg, D.; Wojcik, M.; Hermansson, K. Chem. Phys. Lett. 1997, 276, 114-121) and differs in sign and magnitude from that calculated in this work. We show that this is due to an overestimation of the sodium hydration energy in the previous model. For water exchange around Fe 2+ , transition path sampling predicts an activation volume of +3.8 cm 3 mol -1 , in excellent agreement with available experimental data. The reactive flux approach, however, failed to identify the transition state and predicted the opposite pressure dependence of the rate as a result. Analysis of the reactive trajectories obtained with the transition path sampling approach suggests that the Fe 2+ exchange reaction takes place via an associative interchange mechanism, which goes against the conventional mechanistic interpretation of a positive activation volume. Collectively, considerable insight obtains not only for the exchange rates and mechanisms for Na + and Fe 2+ , but also for identifying the most robust modeling strategy for these purposes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low fractional volume superconductivity in single crystals of Pr{sub 4}Ni{sub 3}O{sub 10} under pressure

Magnetotransport measurements of P⁢r4⁢N⁢i3⁢O10 single crystals performed under externally applied pressures up to 73 GPa in diamond anvil cells with either KBr or Nujol oil as pressure media yield signatures of superconductivity with a maximum onset temperature of approximately 31 K. True zero resistance was not observed, consistent with a nonpercolating superconducting volume fraction. Magnetization measurements provided corroborating evidence of superconductivity, with a pressure-dependent diamagnetic signal occurring below the onset temperature, and an estimate from the absolute value of the susceptibility suggests a superconducting volume fraction on the order of 10%. We observe sample to sample variations in the magnitude and pressure dependence of 𝑇𝑐 as well as a dependence on the configuration of electrical contacts on a given sample. Possible causes of this behavior may be significant inhomogeneities in the pressure and/or damage to the samples induced by the pressure media as well as inhomogeneities in the crystals themselves. The results imply that our as-grown P⁢r4⁢N⁢i3⁢O10 single crystals are not bulk superconductors but that there is a minority structure present within the crystals that is indeed superconductin

Chen, Xinglong↗

Inclusive reactions from finite Minkowski spacetime correlation functions

The need to determine scattering amplitudes of few-hadron systems for arbitrary kinematics expands a broad set of subfields of modern-day nuclear and hadronic physics. In this work, we expand upon previous explorations on the use of real-time methods, like quantum computing or tensor networks, to determine few-body scattering amplitudes. Such calculations must be performed in a finite Minkowski spacetime, where scattering amplitudes are not well defined. Our previous work presented a conjecture of a systematically improvable estimator for scattering amplitudes constructed from finite-volume correlation functions. Here we provide further evidence that the prescription works for larger kinematic regions than previously explored as well as a broader class of scattering amplitudes. Finally, we devise a new method for estimating the order of magnitude of the error associated with finite time separations needed for such calculations. In units of the lightest mass of the theory, we find that to constrain amplitudes using real-time methods within O ( 10 % ) , the spacetime volumes must satisfy m L ∼ O ( 10 – 10 2 ) ) and m T ∼ O ( 10 2 – 10 4 ) . Published by the American Physical Society 2024

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Equivalent GPS measurements for efficient estimation process

Dual-frequency pseudorange and carrier phase data streams can be analytically combined into a single equivalent data stream, reducing the data volume and computing time in the filtering process for parameter estimation by a factor of 2 to 4. The resulting single data stream is that of carrier phase measurements with both data noise and bias uncertainty strictly defined. Based on these analytical formulas the equivalent GPS measurements can be formed by simple and efficient numerical calculations without any degradation in data strength. Formulation for the equivalent GPS measurements and their covariances are given in closed form; and a numerical simulation is performed to demonstrate the validity and effectiveness of the equivalent measurements.

Wu, S. C.↗

Estimation of left ventricular mass in conscious dogs

A method for the assessment of the development or the regression of left ventricular hypertrophy (LVH) in a conscious instrumented animal is described. First, the single-slice short-axis area-length method for estimating the left-ventricular mass (LVM) and volume (LVV) was validated in 24 formaldehyde-fixed canine hearts, and a regression equation was developed that could be used in the intact animal to correct the sonomicrometrically estimated LVM. The LVM-assessment method, which uses the combined techniques of echocardiography and sonomicrometry (in conjunction with the regression equation), was shown to provide reliable and reproducible day-to-day estimates of LVM and LVV, and to be sensitive enough to detect serial changes during the development of LVH.

Coleman, Bernell↗

Near-infrared spectral tomography integrated with digital breast tomosynthesis: Effects of tissue scattering on optical data acquisition design

Purpose: Design optimization and phantom validation of an integrated digital breast tomosynthesis (DBT) and near-infrared spectral tomography (NIRST) system targeting improvement in sensitivity and specificity of breast cancer detection is presented. Factors affecting instrumentation design include minimization of cost, complexity, and examination time while maintaining high fidelity NIRST measurements with sufficient information to recover accurate optical property maps. Methods: Reconstructed DBT slices from eight patients with abnormal mammograms provided anatomical information for the NIRST simulations. A limited frequency domain (FD) and extensive continuous wave (CW) NIRST system was modeled. The FD components provided tissue scattering estimations used in the reconstruction of the CW data. Scattering estimates were perturbed to study the effects on hemoglobin recovery. Breast mimicking agar phantoms with inclusions were imaged using the combined DBT/NIRST system for comparison with simulation results. Results: Patient simulations derived from DBT images show successful reconstruction of both normal and malignant lesions in the breast. They also demonstrate the importance of accurately quantifying tissue scattering. Specifically, 20% errors in optical scattering resulted in 22.6% or 35.1% error in quantification of total hemoglobin concentrations, depending on whether scattering was over- or underestimated, respectively. Limited frequency-domain optical signal sampling provided two regions scattering estimates (for fat and fibroglandular tissues) that led to hemoglobin concentrations that reduced the error in the tumor region by 31% relative to when a single estimate of optical scattering was used throughout the breast volume of interest. Acquiring frequency-domain data with six wavelengths instead of three did not significantly improve the hemoglobin concentration estimates. Simulation results were confirmed through experiments in two-region breast mimicking gelatin phantoms. Conclusions: Accurate characterization of scattering is necessary for quantification of hemoglobin. Based on this study, a system design is described to optimally combine breast tomosynthesis with NIRST.

60 APPLIED LIFE SCIENCES↗