Search NASA⌕ Search

SEARCH · Search NASA

Results for “volume visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Identification of Galaxy–Galaxy Strong Lens Candidates in the DECam Local Volume Exploration Survey Using Machine Learning

We perform a search for galaxy–galaxy strong lens systems using a convolutional neural network (CNN) applied to imaging data from the first public data release of the DECam Local Volume Exploration Survey, which contains ~520 million astronomical sources covering ~4000 deg 2 of the southern sky to a 5σ point–source depth of g = 24.3, r= 23.9, i = 23.3, and z = 22.8 mag. Following the methodology of similar searches using Dark Energy Camera data, we apply color and magnitude cuts to select a catalog of ~11 million extended astronomical sources. After scoring with our CNN, the highest-scoring 50,000 images were visually inspected and assigned a score on a scale from 0 (not a lens) to 3 (very probable lens). We present a list of 581 strong lens candidates, 562 of which are previously unreported. We categorize our candidates using their human-assigned scores, resulting in 55 Grade A candidates, 149 Grade B candidates, and 377 Grade C candidates. We additionally highlight eight potential quadruply lensed quasars from this sample. Due to the location of our search footprint in the northern Galactic cap (b > 10 deg) and southern celestial hemisphere (decl. < 0 deg), our candidate list has little overlap with other existing ground-based searches. Where our search footprint does overlap with other searches, we find a significant number of high-quality candidates that were previously unidentified, indicating a degree of orthogonality in our methodology. We report properties of our candidates including apparent magnitude and Einstein radius estimated from the image separation.

79 ASTRONOMY AND ASTROPHYSICS↗

Three-Dimensional Imaging and Numerical Reconstruction of Graphite/Epoxy Composite Microstructure Based on Ultra-High Resolution X-Ray Computed Tomography

A combined experimental and computational study aimed at high-resolution 3D imaging, visualization, and numerical reconstruction of fiber-reinforced polymer microstructures at the fiber length scale is presented. To this end, a sample of graphite/epoxy composite was imaged at sub-micron resolution using a 3D X-ray computed tomography microscope. Next, a novel segmentation algorithm was developed, based on concepts adopted from computer vision and multi-target tracking, to detect and estimate, with high accuracy, the position of individual fibers in a volume of the imaged composite. In the current implementation, the segmentation algorithm was based on Global Nearest Neighbor data-association architecture, a Kalman filter estimator, and several novel algorithms for virtualfiber stitching, smoothing, and overlap removal. The segmentation algorithm was used on a sub-volume of the imaged composite, detecting 508 individual fibers. The segmentation data were qualitatively compared to the tomographic data, demonstrating high accuracy of the numerical reconstruction. Moreover, the data were used to quantify a) the relative distribution of individual-fiber cross sections within the imaged sub-volume, and b) the local fiber misorientation relative to the global fiber axis. Finally, the segmentation data were converted using commercially available finite element (FE) software to generate a detailed FE mesh of the composite volume. The methodology described herein demonstrates the feasibility of realizing an FE-based, virtual-testing framework for graphite/fiber composites at the constituent level.

Czabaj, M. W.↗

A simulation study of the flight dynamics of elastic aircraft. Volume 1: Experiment, results and analysis

The simulation experiment described addresses the effects of structural flexibility on the dynamic characteristics of a generic family of aircraft. The simulation was performed using the NASA Langley VMS simulation facility. The vehicle models were obtained as part of this research. The simulation results include complete response data and subjective pilot ratings and comments and so allow a variety of analyses. The subjective ratings and analysis of the time histories indicate that increased flexibility can lead to increased tracking errors, degraded handling qualities, and changes in the frequency content of the pilot inputs. These results, furthermore, are significantly affected by the visual cues available to the pilot.

Waszak, Martin R.↗

Air STAR Beyond Visual Range UAS Description and Preliminary Test Results

The NASA Airborne Subscale Transport Aircraft Research Unmanned Aerial System project's capabilities were expanded by updating the system design and concept of operations. The new remotely piloted airplane system design was flight tested to assess integrity and operational readiness of the design to perform flight research. The purpose of the system design is to improve aviation safety by providing a capability to validate, in high-risk conditions, technologies to prevent airplane loss of control. Two principal design requirements were to provide a high degree of reliability and that the new design provide a significant increase in test volume (relative to operations using the previous design). The motivation for increased test volume is to improve test efficiency and allow new test capabilities that were not possible with the previous design and concept of operations. Three successful test flights were conducted from runway 4-22 at NASA Goddard Space Flight Center's Wallops Flight Facility.

Cunningham, Kevin↗

Probing multiscale dissolution dynamics in natural rocks through microfluidics and compositional analysis

Mineral dissolution significantly impacts many geological systems. Carbon released by diagenesis, carbon sequestration, and acid injection are examples where geochemical reactions, fluid flow, and solute transport are strongly coupled. The complexity in these systems involves interplay between various mechanisms that operate at timescales ranging from microseconds to years. Current experimental techniques characterize dissolution processes using static images that are acquired with long measurement times and/or low spatial resolution. These limitations prevent direct observation of how dissolution reactions progress within an intact rock with spatially heterogeneous mineralogy and morphology. We utilize microfluidic cells embedded with thin rock samples to visualize dissolution with significant temporal resolution (100 ms) in a large observation window (3 × 3 mm). Here we injected acidic fluid into eight shale samples ranging from 8 to 86 wt % carbonate. The pre- and postreaction microstructures are characterized at the scale of pores (0.1 to 1 µm) and fractures (1 to 1,000 µm). We observe that nonreactive particle exposure, fracture morphology, and loss of rock strength are strongly dependent on both the relative volume of reactive grains and their distribution. Time-resolved images of the rock unveil the spatiotemporal dynamics of dissolution, including two-phase flow effects in real time and illustrate the changes in the fracture interface across the range of compositions. Moreover, the dynamical data provide an approach for characterizing reactivity parameters of natural heterogeneous samples when porous media effects are not negligible. The platform and workflow provide real-time characterization of geochemical reactions and inform various subsurface engineering processes.

58 GEOSCIENCES↗

Imaging electric field with electrically neutral particles

It used to think that is impossible to determine/measure electric field inside a physically isolated volume, especially inside an electrically shielded space, because a conventional electric-field sensor can only measure electric field at the location of the sensor, and when an electric-field source is screened by conductive materials, no leakage electric field can be detected. For first time, we experimentally demonstrated that electrically neutral particles, neutrons, can be used to measure/image electric field behind a physical barrier. This work enables a new measurement capability that can visualize electric-relevant properties inside a studied sample or detection target for scientific research and engineering applications.

42 ENGINEERING↗

Exploring the Effects of Varying Pre-Chamber Geometry in a Heavy-Duty Natural Gas Optical Engine under Dilution Conditions

Pre-chamber combustion is an advanced ignition strategy that has been shown to enhance spark ignition (SI) combustion stability in natural gas (NG) engines by providing distributed ignition sites from turbulent jets and enhancing main-chamber turbulence. Pre-chamber combustion has been proven especially advantageous compared to SI in ultra-lean and dilute operating conditions. This work involves experimental investigation of the effects of varying passive pre-chamber nozzle configuration on pre-chamber and main chamber combustion under simulated exhaust gas recirculation (EGR) dilution (0 and 20%) conditions in a heavy-duty, single-cylinder, optically accessible NG engine at stoichiometric fuel-air ratio. Pre-chamber nozzle configurations include four pre-chambers with constant nozzle area to pre-chamber volume ratio (A/V) with different nozzle sizes and orientations and one configuration with larger nozzles. The optical engine is operated in a skip-fire sequence consisting of 18 motored cycles followed by two consecutive fired cycles to elucidate the effect of combustion residuals (internal EGR) on combustion evolution. Pressure-based diagnostics are used to monitor pre-chamber and subsequent main chamber combustion, and optical diagnostics include high-speed OH* chemiluminescence to visualize the development of pre-chamber jets and the resulting ignition of the main chamber charge. Heat release analysis of the in-cylinder pressure data indicates that a faster pre-chamber pressure rise does not always translate into faster main-chamber combustion. The pre-chamber with the smallest nozzle diameter produced the highest pre-chamber pressure rise and fastest combustion under non-diluted conditions. However, dilution delays the main chamber ignition for smaller nozzles despite a comparable rise in pre-chamber pressure compared to configurations with larger nozzles. This effect is more pronounced for cycles with in-cylinder combustion residuals in addition to external dilution. Additionally, it was observed that pre-chambers with swirling nozzles have a faster pressure rise in the pre-chamber and main chamber under dilute conditions. Optical diagnostics suggest that the main reason for the delay between the pre-chamber pressure rise and main-chamber combustion lies in jet quenching and delayed re-ignition, which can even lead to misfire if jets emitted from small nozzles combined with dilution fail to re-ignite.

Dhotre, Akash [University Of Minnesota-Twin Cities↗

Influence of Exercise Modality on Cerebral-Ocular Hemodynamics and Pressures

Background: Moderate and high intensity aerobic or resistance exercise has clearly identified benefits for cardiac, muscle, and bone health. However, the impact of such exercise - either as a mitigating or an exacerbating factor - on the development of the visual impairment and intracranial pressure syndrome (VIIP) is unknown. Accordingly, our aim was to characterize the effect of an acute bout of resistance (RE), moderate-intensity continuous (CE), and high-intensity interval exercise (IE) during a cephalad fluid shift on cerebral-ocular hemodynamics and pressures. Methods: 10 male subjects (36 plus or minus 9 years) completed 4 testing days in a 15 degree head-down tilt (HDT): (1) assessment of maximum volume of O (sub 2), (2) RE session (4 sets of 12 repetition maximum leg press exercise), (3) CE session (30 minutes of cycling at 60 percent maximum volume of O (sub 2)), and (4) IE session (4 by 4-minute intervals of exercise at 85 percent maximum volume of O (sub 2) with 3-minute active rest periods). During each session, blood flow (Vivid-e, GE Healthcare) in extracranial arteries (common carotid artery, CCA; internal carotid artery, ICA; external carotid artery, ECA and vertebral artery, VA), and mean blood flow velocity in middle cerebral artery (MCA), internal jugular pressure (IJP; VeinPress), and intraocular pressure (IOP; Icare PRO) were measured at rest, at the end of each resistance or interval set, and every 5 minutes during continuous exercise. Translaminar pressure gradient (TLPG) was estimated by subtracting IJP from IOP. Results: There were no differences across days in pre-exercise resting blood flows or pressures. IOP decreased slightly from HDT rest (20.2 plus or minus 2.3 millimeters of mercury) to exercise (RE: 19.2 plus or minus 2.8 millimeters of mercury; CE: 18.9 plus or minus 3.2 millimeters of mercury; IE: 20.1 plus or minus 2.8 millimeters of mercury), while IJP decreased during CE (31.6 plus or minus 9.5 millimeters of mercury) and RE (32.0 plus or minus 8.1 millimeters of mercury), and increased during IE (35.1 plus or minus 9.5 millimeters of mercury) from HDT rest (33.3 plus or minus 6.5 millimeters of mercury). Estimated TLPG was increased during IE only. Compared to RE and CE, IE resulted in the greatest increase in MCA blood flow velocity and extracranial artery blood flow. Conclusions: These preliminary results suggest that high-intensity IE acutely increases cerebral blood flow, IJP, and TLPG. Alterations in TLPG is one mechanism that may contribute to optic nerve sheath edema in astronauts. Accordingly, acutely raising IOP and/or orbital pressure during exercise could optimize cerebral-ocular pressures during spaceflight.

Scott, J.↗

A scalable messaging system for accelerating discovery from large scale scientific simulations

Emerging scientific and engineering simulations running at scale on leadership-class High End Computing (HEC) environments are producing large volumes of data, which has to be transported and analyzed before any insights can result from these simulations. The complexity and cost (in terms of time and energy) associated with managing and analyzing this data have become significant challenges, and are limiting the impact of these simulations. Recently, data-staging approaches along with in-situ and in-transit analytics have been proposed to address these challenges by offloading I/O and/or moving data processing closer to the data. However, scientists continue to be overwhelmed by the large data volumes and data rates. In this paper we address this latter challenge. Specifically, we propose a highly scalable and low-overhead associative messaging framework that runs on the data staging resources within the HEC platform, and builds on the staging-based online in-situ/in- transit analytics to provide publish/subscribe/notification-type messaging patterns to the scientist. Rather than having to ingest and inspect the data volumes, this messaging system allows scientists to (1) dynamically subscribe to data events of interest, e.g., simple data values or a complex function or simple reduction (max()/min()/avg()) of the data values in a certain region of the application domain is greater/less than a threshold value, or certain spatial/temporal data features or data patterns are detected; (2) define customized in-situ/in-transit actions that are triggered based on the events, such as data visualization or transformation; and (3) get notified when these events occur. The key contribution of this paper is a design and implementation that can support such a messaging abstraction at scale on high- end computing (HEC) systems with minimal overheads. We have implemented and deployed the messaging system on the Jaguar Cray XK6 machines at Oak Ridge National Laboratory and the Lonestar system at the Texas Advanced Computing Center (TACC), and we present the experimental performance evaluation using these HEC platforms in the paper.

Jin, Tong↗

High-speed synchrotron X-ray phase-contrast imaging for evaluating microscale damage mechanisms and tracking cracking behaviors inside cross-ply GFRCs

In this study, we integrated the high-speed synchrotron X-ray phase-contrast imaging (PCI) with a modified Kolsky compression bar loading platform to visualize the dynamic failure processes of cross-ply glass fiber reinforced composites (GFRCs). Four S-2 glass/SC-15 composite specimens were prepared, having similar thicknesses but different stacking sequences, namely as [0 12 /90 12 ], [90 12 /0 12 ], [0 8 /90 8 /0 8 ], and [90 8 /0 8 /90 8 ]. Three-dimensional synchrotron X-ray computed tomography and scanning electron microscopy (SEM) were employed to examine the microstructures and quantify the fiber volume fractions. Each specimen was notched and subjected to a dynamic three-point flexural loading. The onset of cracking close to the notch tip, crack propagation in 0° or 90° plies and their interface, crack opening, and ultimately failure of the specimen were captured by high-speed synchrotron X-ray PCI. Additional dynamic experiments were performed to determine the average time when the stress wave propagated through the specimen and correlate the X-ray images with the specimen&#x27;s force-deflection response. Finally, the surface morphology of each specimen after the dynamic loading was imaged by SEM. Comparison between real-time X-ray images and post-fracture SEM images demonstrated the capability of the X-ray method to record damage evolution inside composites. Furthermore, the high spatial and temporal resolutions of the X-ray setup and edge enhancement by PCI enabled the identification of microscale damage features within 1 μs. Two damaging processes were identified, crack growth was quantified, and fracture toughness of the composites was evaluated. The method is deemed useful to reveal microscale damage mechanisms and track cracking behaviors inside cross-ply GFRCs under dynamic loading in real time.

42 ENGINEERING↗

Flow boiling in geometrically modified microchannels

Microchannels are a promising solution for high-heat-flux thermal management scenarios, including high-performance microelectronics cooling and power electronics cooling. However, thermohydraulic instabilities result from the rapid vapor bubble formation. The prior literature has examined several methods, including constricted inlet microchannels, expanding microchannels, and auxiliary jetting microchannels, to mitigate the effect of these instabilities. Computational fluid dynamics and heat transfer (CFD/HT) modeling of the flow boiling phenomena in these microchannel configurations has seen limited examination, and one-to-one numerical comparisons of the different mitigation strategies have not been performed. In the present investigation, CFD/HT analyses using a three-dimensional (3D) volume of fluid model coupled with a phase-change model for the interfacial heat and mass transfer were performed for multiple microchannel configurations (constricted inlet, expanding, and auxiliary jetting microchannels). A benchmark case of a rectangular microchannel was examined to quantify baseline thermohydraulic performance. Results demonstrated slight to significant thermal performance improvements for all cases, and significant pressure benefits for the expanding and jetting cases, consistent with experimental results in the literature. Bubble dynamics and visualization for the baseline and alternative configurations are provided to give insight into their underlying physics, and the differences in performance were investigated and compared with available literature.

Broughton, Justin (ORCID:000000026848457X)↗

Assessing the Relationships Between Sensorimotor Biomarkers and Post-Landing Functional Task Performance

Spaceflight drives adaptive changes in healthy individuals appropriate for sensorimotor function in a microgravity environment. These changes are maladaptive for return to earth's gravity. The inter-individual variability of sensorimotor decrements is striking, although poorly understood. The goal of this study was to identify a set of behavioral, neuroimaging and genetic measures that can be used to predict early post-flight performance on a set of sensorimotor tasks. Astronauts were recruited who previously participated in sensorimotor field tests and/or posturography soon after long-duration spaceflight. Behavioral tests included assessments of sensory dependency and adaptability. Visual dependency involved treadmill walking while viewing a moving virtual visual scene. Vestibular perceptual thresholds were measured while seated during lateral translations. Proprioception dependency was measured during one-legged stance on a horizontal air-bearing surface. Ground assessment of adaptability was performed (1) during treadmill walking with a virtual linear hallway and a moving walking surface, and (2) during multiple trials of navigating an obstacle course while wearing reversing prisms (adaptive Functional Mobility Test, aFMT). The neuroimaging tests characterized individual differences in regional brain volumes (using Structural MRI) and white matter microstructure (using Diffusion Tensor Imaging) to serve as potential predictors of adaptive capacity. The genetic tests utilized saliva samples to examine variations in four genes chosen because of their ability to differentiate sensorimotor adaptation ability in a normative population, including Catechol-O-methyltransferase (COMT), Dopamine Receptor D2 (DRD2), Brain-derived neurotrophic factor (BDNF) and the α2-adrenergic receptor. Thirty ISS crewmembers were recruited, including 12 first-time fliers, 6F, and mission durations lasting 185.5 ± 45.5 days, mean ± std. We utilized a combination of three post-flight functional task outcomes: tandem walk, recovery from fall and dynamic posturography. There was considerable variability among all post-flight performance outcomes. Based on an ordinal scale survey, 72% indicated their ability to perform functional tasks were more impacted postflight relative to inflight with 50% indicating they needed to restrict movements for a longer period postflight relative to inflight. While there is a strong association within tests obtained at different R+0 timepoints, by R+24 hr performance on one post-flight test does not necessarily correlate with performance on other post-flight tests. Preliminary statistical analysis indicates combining biomarkers will increase predictive power and this will be explored with future analyses. Our preliminary findings underscore the importance of a comprehensive post-flight test battery including different types of tasks with varying sensory feedback. Understanding the relationships between these sensorimotor biomarkers and post-flight functional task performance improve both our understanding of the individual variability and our strategy to optimize sensorimotor countermeasures.

biomarkers↗

WE-E-BRF-01: The ESTRO-AAPM Joint Symposium On Imaging for Proton Treatment Planning and Guidance

In this first inaugural joint ESTRO-AAPM session we will attempt to provide some answers to the problems encountered in the clinical application of particle therapy. Indeed the main advantage is that the physical properties of ion beams offer high ballistic accuracy for tightly conformal irradiation of the tumour volume, with excellent sparing of surrounding healthy tissue and critical organs, This also its Achilles' heel calling for an increasing role of imaging to ensure safe application of the intended dose to the targeted area during the entire course of fractionated therapy. We have three distinguished speakers addressing possible solutions. Katia Parodi (Ludwig Maximilians University, Munich, Germany) To date, Positron Emission Tomography (PET) is the only technique which has been already clinically investigated for in-vivo visualization of the beam range during or shortly after ion beam delivery. The method exploits the transient amount of β{sup 2}-activity induced in nuclear interactions between the primary beam and the irradiated tissue, depending on the ion beam species, the tissue elemental composition and physiological properties (in terms of biological clearance), as well as the time course of irradiation and imaging. This contribution will review initial results, ongoing methodological developments and remaining challenges related to the clinical usage of viable but often suboptimal instrumentation and workflows of PET-based treatment verification. Moreover, it will present and discuss promising new detector developments towards next-generation dedicated PET scanners relying on full-ring or dual-head designs for in-beam quasi real-time imaging. Denis Dauvergne (Institut de Physique Nucleaire de Lyon, Lyon, France) Prompt gamma radiation monitoring of hadron therapy presents the advantage of real time capability to measure the ion range. Both simulations and experiments show that millimetric verification of the range can be achieved at the pencil beam scale for active proton beam delivery in homogenous targets. The development of gamma cameras, that has been studied by several groups worldwide over the last years, now reaches - for some of them - the stage of being applicable in clinical conditions, with real size prototypes and count rate capability matching the therapeutic beam intensities. We will review the different concepts of gamma cameras, the advantages and limitations of this method, and the main challenges that should still be overcome before the widespread of prompt gamma quality assurance for proton and hadrontherapy. Jon Kruse (Mayo Clinic, Rochester, MN, USA) Treatment simulation images for proton therapy are used to determine proton stopping power and range in the patient. This talk will discuss the careful control of CT numbers and conversion of CT number to stopping power required in proton therapy. Imaging for treatment guidance of proton therapy also presents unique challenges which will be addressed. Among them are the enhanced relationship between internal anatomy changes and dosimetry, the need for imaging to support adaptive planning protocols, and high operational efficiency. Learning Objectives: To learn about the possibilities of using activation products to determine the range of particle beams in a patient treatment setting To be informed on an alternative methodology using prompt gamma detectors To understand the impact of the accuracy of the knowledge of the patient information with respect to the delivered treatment.

60 APPLIED LIFE SCIENCES↗

Poster — Thur Eve — 70: Automatic lung bronchial and vessel bifurcations detection algorithm for deformable image registration assessment

Purpose: To investigate an automatic bronchial and vessel bifurcations detection algorithm for deformable image registration (DIR) assessment to improve lung cancer radiation treatment. Methods: 4DCT datasets were acquired and exported to Varian treatment planning system (TPS) EclipseTM for contouring. The lungs TPS contour was used as the prior shape for a segmentation algorithm based on hierarchical surface deformation that identifies the deformed lungs volumes of the 10 breathing phases. Hounsfield unit (HU) threshold filter was applied within the segmented lung volumes to identify blood vessels and airways. Segmented blood vessels and airways were skeletonised using a hierarchical curve-skeleton algorithm based on a generalized potential field approach. A graph representation of the computed skeleton was generated to assign one of three labels to each node: the termination node, the continuation node or the branching node. Results: 320 ± 51 bifurcations were detected in the right lung of a patient for the 10 breathing phases. The bifurcations were visually analyzed. 92 ± 10 bifurcations were found in the upper half of the lung and 228 ± 45 bifurcations were found in the lower half of the lung. Discrepancies between ten vessel trees were mainly ascribed to large deformation and in regions where the HU varies. Conclusions: We established an automatic method for DIR assessment using the morphological information of the patient anatomy. This approach allows a description of the lung's internal structure movement, which is needed to validate the DIR deformation fields for accurate 4D cancer treatment planning.

60 APPLIED LIFE SCIENCES↗

SU-E-J-230: Evaluation of ViewRay 0.35 T MRI Normal Structure Segmentation

Purpose: In order to take advantage of the high resolution soft tissue imaging available in MR images, we investigated 3D images obtained with the low field 0.35 T MR in ViewRay to serve as an alternative to CT scans for radiotherapy treatment planning. In these images, normal and target structure delineation can be visualized. Assessment is based upon comparison with the CT images and the ability to produce comparable contours. Methods: Routine radiation oncology CT scans were acquired on five patients. Contours of brain, brainstem, esophagus, heart, lungs, spinal cord, and the external body were drawn. The same five patients were then scanned on the ViewRay TrueFISP-based imaging pulse sequence. The same organs were selected on the MR images and compared to those from the CT scan. Physical volume and the Dice Similarity Coefficient (DSC) were used to assess the contours from the two systems. Image quality stability was quantitatively ensured throughout the study following the recommendations of the ACR MR accreditation procedure. Results: The highest DSC of 0.985, 0.863, and 0.843 were observed for brain, lungs, and heart respectively. On the other hand, the brainstem, spinal cord, and esophagus had the lowest DSC. Volume agreement was most satisfied for the heart (within 5%) and the brain (within 2%). Contour volume for the brainstem and lung (a widely dynamic organ) varied the most (27% and 19%). Conclusion: The DSC and volume measurements suggest that the results obtained from ViewRay images are quantitatively consistent and comparable to those obtained from CT scans for the brain, heart, and lungs. MR images from ViewRay are well-suited for treatment planning and for adaptive MRI-guided radiotherapy. The physical data from 0.35 T MR imaging is consistent with our geometrical understanding of normal structures.

60 APPLIED LIFE SCIENCES↗

TH-EF-BRA-11: Feasibility of Super-Resolution Time-Resolved 4DMRI for Multi-Breath Volumetric Motion Simulation in Radiotherapy Planning

Purpose: To develop a novel super-resolution time-resolved 4DMRI technique to evaluate multi-breath, irregular and complex organ motion without respiratory surrogate for radiotherapy planning. Methods: The super-resolution time-resolved (TR) 4DMRI approach combines a series of low-resolution 3D cine MRI images acquired during free breathing (FB) with a high-resolution breath-hold (BH) 3DMRI via deformable image registration (DIR). Five volunteers participated in the study under an IRB-approved protocol. The 3D cine images with voxel size of 5×5×5 mm{sup 3} at two volumes per second (2Hz) were acquired coronally using a T1 fast field echo sequence, half-scan (0.8) acceleration, and SENSE (3) parallel imaging. Phase-encoding was set in the lateral direction to minimize motion artifacts. The BH image with voxel size of 2×2×2 mm{sup 3} was acquired using the same sequence within 10 seconds. A demons-based DIR program was employed to produce super-resolution 2Hz 4DMRI. Registration quality was visually assessed using difference images between TR 4DMRI and 3D cine and quantitatively assessed using average voxel correlation. The fidelity of the 3D cine images was assessed using a gel phantom and a 1D motion platform by comparing mobile and static images. Results: Owing to voxel intensity similarity using the same MRI scanning sequence, accurate DIR between FB and BH images is achieved. The voxel correlations between 3D cine and TR 4DMRI are greater than 0.92 in all cases and the difference images illustrate minimal residual error with little systematic patterns. The 3D cine images of the mobile gel phantom preserve object geometry with minimal scanning artifacts. Conclusion: The super-resolution time-resolved 4DMRI technique has been achieved via DIR, providing a potential solution for multi-breath motion assessment. Accurate DIR mapping has been achieved to map high-resolution BH images to low-resolution FB images, producing 2Hz volumetric high-resolution 4DMRI. Further validation and improvement are still required prior to clinical applications. This study is in part supported by the NIH (U54CA137788/U54CA132378).

60 APPLIED LIFE SCIENCES↗

Assessing the Relationships Between Sensorimotor Biomarkers and Post-Landing Functional Task Performance

Spaceflight drives adaptive changes in healthy individuals appropriate for sensorimotor function in a microgravity environment. These changes are maladaptive for return to earth's gravity. The inter-individual variability of sensorimotor decrements is striking, although poorly understood. The goal of this study is to identify a set of behavioral, neuroimaging and genetic measures that can be used to predict early post-flight performance on a set of sensorimotor tasks. Astronauts are recruited who previously participated in sensorimotor field tests and/or posturography soon after long-duration spaceflight. Behavioral tests include assessments of sensory dependency and adaptability. Visual dependency involves treadmill walking while viewing a moving virtual visual scene. Vestibular perceptual thresholds are measured while seated during lateral translations. Proprioception dependency is measured during one-legged stance on a horizontal air-bearing surface. Ground assessment of adaptability is performed(1) during treadmill walking with a virtual linear hallway and a moving walking surface, and (2) during multiple trials of navigating an obstacle course while wearing reversing prisms(adaptive Functional Mobility Test, aFMT). The neuroimaging tests will characterize individual differences in regional brain volumes (using Structural MRI) and white matter microstructure(using Diffusion Tensor Imaging) to serve as potential predictors of adaptive capacity. The genetic tests will utilize saliva samples to examine variations in four genes chosen because of their ability to differentiate sensorimotor adaptation ability in a normative population, including Catechol-O-methyltransferase (COMT), Dopamine Receptor D2 (DRD2), Brain-derived neurotrophic factor (BDNF) and the α2-adrenergic receptor. Twenty-seven ISS crewmembers have been tested to date, including 6 from this past year. This cohort includes 10first-time fliers, 6F, and mission durations lasting 178.6 ± 30.5 days, mean ± std. We are utilizing a combination of three post-flight functional task outcomes: tandem walk, recovery from fall and dynamic posturography. There is considerable variability among the post-flight performance outcomes for the 27participants to date. Based on a partial sample using an ordinal scale survey, 70% indicated their ability to perform functional tasks were more impacted postflight relative to inflight with 50% indicating they needed to restrict movements for a longer period postflight relative to inflight. While there is a strong association within tests obtained at different R+0 timepoints, by R+24 hr performance on one post-flight test does not necessarily correlate with performance on other post-flight tests. There are apparent relationships between individual measures and specific post-flight outcome measures, e.g., the cumulative time to complete the aFMT is significantly correlated to pre-to-post-flight changes in tandem walk (rho= 0.64, p = 0.001). Preliminary statistical analysis indicates combining biomarkers will increase predictive power and this will be explored with future analyses. Our preliminary findings underscore the importance of a comprehensive post-flight test battery including different types of tasks with varying sensory feedback. We expect that understanding the relationships between these sensorimotor biomarkers and post-flight functional task performance will improve both our understanding of the individual variability and our strategy to optimize sensorimotor countermeasures

S J Wood↗

Deliquescence of eutectic LiCl-KCl diluted with NaCl for interim waste salt storage

Molten eutectic LiCl-KCl salt is a widely used electrolyte for electrorefining uranium from spent nuclear fuel. Due to the hygroscopic nature of this salt, careful handling and storage of solidified waste electrorefiner (ER) salt is required to avoid deliquescence and corrosion of container materials. This study investigated a potential processing path for reducing the deliquescence through dilution with NaCl. The hydration behavior of LiCl-KCl salts diluted with NaCl was evaluated in terms of mass gain due to mass of water absorption, visual evidence of deliquescence, and visual evidence of corrosion to stainless steel containers in a humid air environment. Pure eutectic LiCl-KCl exhibited a 50 mass% increase due to water absorption and showed signs of deliquescence after 24 hours. 89 mass% NaCl was required in order to prevent deliquescence. Dilution with 89% NaCl was also found to protect corrosion to stainless steel crucibles. Corrosion, thus, appears to require deliquescence. While NaCl dilution greatly decreases steady state hydration and eliminated deliquescence, storage volume is increased ~10x.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗