Search NASA⌕ Search

SEARCH · Search NASA

Results for “weights”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Role of Diffusion-Weighted Magnetic Resonance Imaging in Predicting Sensitivity to Chemoradiotherapy in Muscle-Invasive Bladder Cancer

Purpose: In chemoradiation (CRT)-based bladder-sparing approaches for muscle invasive bladder cancer (MIBC), patients who respond favorably to induction CRT enjoy the benefits of bladder preservation, whereas nonresponders do not. Thus, accurate prediction of CRT sensitivity would optimize patient selection for bladder-sparing protocols. Diffusion-weighted MRI (DW-MRI) is a functional imaging technique that quantifies the diffusion of water molecules in a noninvasive manner. We investigated whether DW-MRI predicts CRT sensitivity of MIBC. Methods and Materials: The study cohort consisted of 23 MIBC patients (cT2/T3 = 7/16) who underwent induction CRT consisting of radiotherapy to the small pelvis (40 Gy) with two cycles of cisplatin (20 mg/day for 5 days), followed by partial or radical cystectomy. All patients underwent DW-MRI before the initiation of treatment. Associations of apparent diffusion coefficient (ADC) values with CRT sensitivity were analyzed. The proliferative potential of MIBC was also assessed by analyzing the Ki-67 labeling index (LI) in pretherapeutic biopsy specimens. Results: Thirteen patients (57%) achieved pathologic complete response (pCR) to CRT. These CRT-sensitive MIBCs showed significantly lower ADC values (median, 0.63 Multiplication-Sign 10{sup -3} mm{sup 2}/s; range, 0.43-0.77) than CRT-resistant (no pCR) MIBCs (median, 0.84 Multiplication-Sign 10{sup -3} mm{sup 2}/s; range, 0.69-1.09; p = 0.0003). Multivariate analysis identified ADC value as the only significant and independent predictor of CRT sensitivity (p < 0.0001; odds ratio per 0.001 Multiplication-Sign 10{sup -3} mm{sup 2}/s increase, 1.03; 95% confidence interval, 1.01-1.08). With a cutoff ADC value at 0.74 Multiplication-Sign 10{sup -3} mm{sup 2}/s, sensitivity/specificity/accuracy in predicting CRT sensitivity was 92/90/91%. Ki-67 LI was significantly higher in CRT-sensitive MIBCs (p = 0.0005) and significantly and inversely correlated with ADC values ({rho} = -0.67, p = 0.0007). Conclusions: DW-MRI is a potential biomarker for predicting CRT sensitivity in MIBC. DW-MRI may be useful to optimize patient selection for CRT-based bladder-sparing approaches.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Role of Diffusion-Weighted Magnetic Resonance Imaging in the Treatment Response Evaluation of Hepatocellular Carcinoma Patients Treated With Radiation Therapy

Purpose: We investigated the role of diffusion-weighted magnetic resonance imaging (DW MRI) as a response evaluation indicator for hepatocellular carcinoma (HCC) treated with radiation therapy (RT). Methods and Materials: Inclusion criteria of this retrospective study were DW MRI acquisition within 1 month before and 3 to 5 months after RT. In total, 48 patients were enrolled. Two radiation oncologists measured the apparent diffusion coefficient (ADC). Possible predictive factors, including alteration of the ADC value before and 3 to 5 month after RT, in relation to local progression-free survival (LPFS) were analyzed and compared. Results: Three months after RT, 6 patients (12.5%) showed a complete response, and 27 patients (56.3%) showed a partial response when evaluated using the modified response evaluation criteria in solid tumors (mRECIST). The average ADC ± SD values were 1.21 ± 0.27 ( × 10{sup −3} mm{sup 2}/s) before and 1.41 ± 0.36 ( × 10{sup −3} mm{sup 2}/s) after RT (P<.001). The most significant prognostic factor related to LPFS was mRECIST (P<.001). The increment of ADC value (≥20%) was also a significant factor (P=.02), but RECIST (version 1.1; P=.11) was not. When RECIST was combined with the increment of ADC value (≥20%), the LPFS rates were significantly different between the groups (P=.004), and the area under the curve value (0.745) was comparable with that of mRECIST (0.765). Conclusions: ADC value change before and after RT in HCC was closely related to LPFS. ADC value and RECIST may substitute for mRECIST in patients who cannot receive contrast agents.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated and Semiautomated Segmentation of Rectal Tumor Volumes on Diffusion-Weighted MRI: Can It Replace Manual Volumetry?

Purpose: Diffusion-weighted imaging (DWI) tumor volumetry is promising for rectal cancer response assessment, but an important drawback is that manual per-slice tumor delineation can be highly time consuming. This study investigated whether manual DWI-volumetry can be reproduced using a (semi)automated segmentation approach. Methods and Materials: Seventy-nine patients underwent magnetic resonance imaging (MRI) that included DWI (highest b value [b1000 or b1100]) before and after chemoradiation therapy (CRT). Tumor volumes were assessed on b1000 (or b1100) DWI before and after CRT by means of (1) automated segmentation (by 2 inexperienced readers), (2) semiautomated segmentation (manual adjustment of the volumes obtained by method 1 by 2 radiologists), and (3) manual segmentation (by 2 radiologists); this last assessment served as the reference standard. Intraclass correlation coefficients (ICC) and Dice similarity indices (DSI) were calculated to evaluate agreement between different methods and observers. Measurement times (from a radiologist's perspective) were recorded for each method. Results: Tumor volumes were not significantly different among the 3 methods, either before or after CRT (P=.08 to .92). ICCs compared to manual segmentation were 0.80 to 0.91 and 0.53 to 0.66 before and after CRT, respectively, for the automated segmentation and 0.91 to 0.97 and 0.61 to 0.75, respectively, for the semiautomated method. Interobserver agreement (ICC) pre and post CRT was 0.82 and 0.59 for automated segmentation, 0.91 and 0.73 for semiautomated segmentation, and 0.91 and 0.75 for manual segmentation, respectively. Mean DSI between the automated and semiautomated method were 0.83 and 0.58 pre-CRT and post-CRT, respectively; DSI between the automated and manual segmentation were 0.68 and 0.42 and 0.70 and 0.41 between the semiautomated and manual segmentation, respectively. Median measurement time for the radiologists was 0 seconds (pre- and post-CRT) for the automated method, 41 to 69 seconds (pre-CRT) and 60 to 67 seconds (post-CRT) for the semiautomated method, and 180 to 296 seconds (pre-CRT) and 84 to 91 seconds (post-CRT) for the manual method. Conclusions: DWI volumetry using a semiautomated segmentation approach is promising and a potentially time-saving alternative to manual tumor delineation, particularly for primary tumor volumetry. Once further optimized, it could be a helpful tool for tumor response assessment in rectal cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fractionation Spares Mice From Radiation-Induced Reductions in Weight Gain But Does Not Prevent Late Oligodendrocyte Lineage Side Effects

Purpose: To determine the late effects of fractionated versus single-dose cranial radiation on murine white matter. Methods and Materials: Mice were exposed to 0 Gy, 6 × 6 Gy, or 1 × 20 Gy cranial irradiation at 10 to 12 weeks of age. Endpoints were assessed through 18 months from exposure using immunohistochemistry, electron microscopy, and electrophysiology. Results: Weight gain was temporarily reduced after irradiation; greater loss was seen after single versus fractionated doses. Oligodendrocyte progenitor cells were reduced early and late after both single and fractionated irradiation. Both protocols also increased myelin g-ratio, reduced the number of nodes of Ranvier, and promoted a shift in the proportion of small, unmyelinated versus large, myelinated axon fibers. Conclusions: Fractionation does not adequately spare normal white matter from late radiation side effects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Short Diffusion Time Diffusion-Weighted Imaging With Oscillating Gradient Preparation as an Early Magnetic Resonance Imaging Biomarker for Radiation Therapy Response Monitoring in Glioblastoma: A Preclinical Feasibility Study

To investigate a novel alternative diffusion-weighted imaging (DWI) approach using oscillating gradients preparation (OGSE) to obtain much shorter effective diffusion times (Δ{sub eff}) for tumor response monitoring by apparent diffusion coefficient (ADC) mapping in a glioblastoma mouse model.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Physics-based adaptivity of a spectral method for the Vlasov–Poisson equations based on the asymmetrically-weighted Hermite expansion in velocity space

We propose a spectral method for the 1D-1V Vlasov–Poisson system where the discretization in velocity space is based on asymmetrically-weighted Hermite functions, dynamically adapted via a scaling α and shifting u of the velocity variable. Specifically, at each time instant an adaptivity criterion selects new values of α and u based on the numerical solution of the discrete Vlasov–Poisson system obtained at that time step. Once the new values of the Hermite parameters α and u are fixed, the Hermite expansion is updated and the discrete system is further evolved for the next time step. The procedure is applied iteratively over the desired temporal interval. The key aspects of the adaptive algorithm are: the map between approximation spaces associated with different values of the Hermite parameters that preserves total mass, momentum and energy; and the adaptivity criterion to update α and u based on physics considerations relating the Hermite parameters to the average velocity and temperature of each plasma species. For the discretization of the spatial coordinate, we rely on Fourier functions and use the implicit midpoint rule for time stepping. The resulting numerical method possesses intrinsically the property of fluid-kinetic coupling, where the low-order terms of the expansion are akin to the fluid moments of a macroscopic description of the plasma, while kinetic physics is retained by adding more spectral terms. Moreover, the scheme features conservation of total mass, momentum and energy associated in the discrete, for periodic boundary conditions. A set of numerical experiments confirms that the adaptive method outperforms the non-adaptive one in terms of accuracy and stability of the numerical solution.

97 MATHEMATICS AND COMPUTING↗

A new re-redistribution scheme for weighted state redistribution with adaptive mesh refinement

State redistribution (SRD) is a recently developed technique for stabilizing cut cells that result from finite-volume embedded boundary methods. SRD has been successfully applied to a variety of compressible and incompressible flow problems. When used in conjunction with adaptive mesh refinement (AMR), additional steps are needed to preserve the accuracy and conservation properties of the solution if the embedded boundary is not restricted to a single level of the mesh hierarchy. In this work, we extend the weighted state redistribution algorithm to cases where cut cells live at or near a coarse-fine interface within the domain. Here, we present numerical results that demonstrate that the algorithm is conservative when the coarse-fine interface intersects the embedded boundary. Additionally we compare the numerical solution of the Sod shock tube problem in an inclined cylinder with the analytic solution, and we compare the simulation of a shock hitting a cylindrical obstacle with experimental data. Finally we demonstrate the methodology for simulation of the multicomponent compressible Navier-Stokes equations in a piston-bowl geometry, and discuss the computational efficiency gained by not requiring the entire embedded boundary to be defined at the finest level.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hyperintensity in the Dentate Nucleus on Nonenhanced T1-Weighted Magnetic Resonance Imaging Suggests Dechelation of Contrast Agents

With the exception of renal failure patients, gadolinium-based contrast agents (GBCAs) for magnetic resonance imaging (MRI) have a high tolerance and acceptability in patients needing to undergo an enhanced MRI. Now that enhanced MRIs are becoming increasingly popular and nephrogenic systemic fibrosis cases are becoming a rarity, a common belief is that these GBCAs are essentially “biologically inert” materials. However, recent reports have emerged querying the link between these GBCAs and hyperintensity in the dentate nucleus on unenhanced T1-weighted MRI in some patients. This review article outlines the basic chemistry and characteristics of currently approved GBCAs, summarizes the described research findings of gadolinium deposition in the dentate nucleus, and identifies areas for future research.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diffusion-weighted Magnetic Resonance Imaging in Non-traumatic Vertebral Collapse: A Relook Into Its Utility in Making the Diagnosis in a Population Where Infections of Spine Are a Common Cause

Magnetic resonance imaging (MRI) is the imaging investigation of choice in vertebral collapse. In this study, we considered various MRI features and appearance based on morphological features, signal intensity, contrast enhancement characteristics, and diffusion-weighted imaging (DWI) of various types of non-traumatic vertebral collapse for differentiating benign from malignant causes and its role in differentiating cases of infectious causes of vertebral collapse from malignant causes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Relative plan robustness of step-and-shoot vs rotational intensity–modulated radiotherapy on repeat computed tomographic simulation for weight loss in head and neck cancer

Introduction: Interfractional anatomical alterations may have a differential effect on the dose delivered by step-and-shoot intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT). The increased degrees of freedom afforded by rotational delivery may increase plan robustness (measured by change in target volume coverage and doses to organs at risk [OARs]). However, this has not been evaluated for head and neck cancer. Materials and methods: A total of 10 patients who required repeat computed tomography (CT) simulation and replanning during head and neck IMRT were included. Step-and-shoot IMRT and VMAT plans were generated from the original planning scan. The initial and second CT simulation scans were fused and targets/OAR contours transferred, reviewed, and modified. The plans were applied to the second CT scan and doses recalculated without repeat optimization. Differences between step-and-shoot IMRT and VMAT for change in target volume coverage and doses to OARs between first and second CT scans were compared by Wilcoxon signed rank test. Results: There were clinically relevant dosimetric changes between the first and the second CT scans for both the techniques (reduction in mean D{sub 95%} for PTV2 and PTV3, D{sub min} for CTV2 and CTV3, and increased mean doses to the parotid glands). However, there were no significant differences between step-and-shoot IMRT and VMAT for change in any target coverage parameter (including D{sub 95%} for PTV2 and PTV3 and D{sub min} for CTV2 and CTV3) or dose to any OARs (including parotid glands) between the first and the second CT scans. Conclusions: For patients with head and neck cancer who required replanning mainly due to weight loss, there were no significant differences in plan robustness between step-and-shoot IMRT and VMAT. This information is useful with increased clinical adoption of VMAT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Structural and antibacterial properties of NSAID-loaded ultra-high molecular weight polyethylene

Peri-articular delivery of pain medication in joint arthroplasty has the potential to address post-operative pain and decrease the use of systemic opioids. Additionally, the sustained release from a delivery vehicle may be especially impactful in the initial post-operative period when pain is most severe. We recently described a novel approach for the sustained intra-articular delivery of an analgesic (bupivacaine) from an ultra-high molecular weight polyethylene (UHMWPE) bearing surface. A secondary but very significant effect of incorporating bupivacaine in UHMWPE was its antibacterial effect against Staphylococcal species, which are associated with the majority of periprosthetic joint infections. Here, we report on the structure, properties, elution characteristics and antibacterial properties of UHMWPE loaded with the non-steroidal anti-inflammatory drug (NSAID) — tolfenamic acid. We showed that 6 wt% drug loading was optimal for eluting clinically relevant intra-articular and systemic concentrations, for maintaining mechanical properties at a clinically relevant level, and for providing anti-colonization potential against low risk (planktonic) and high risk (biofilm forming) Staphylococcal species. We determined the osteoblast response to the tolfenamic acid-loaded UHMWPE to evaluate the cytotoxicity profile of this novel material. Tolfenamic acid-loaded UHMWPE has the potential to be used as a part of multimodal pain management therapy following arthroplasty and may provide prophylaxis for periprosthetic infection.

36 MATERIALS SCIENCE↗

Incorporating Experimental Information in the Total Monte Carlo Methodology Using File Weights

Some criticism has been directed towards the Total Monte Carlo method because experimental information has not been taken into account in a statistically well-founded manner. In this work, a Bayesian calibration method is implemented by assigning weights to the random nuclear data files and the method is illustratively applied to a few applications. In some considered cases, the estimated nuclear data uncertainties are significantly reduced and the central values are significantly shifted. The study suggests that the method can be applied both to estimate uncertainties in a more justified way and in the search for better central values. Some improvements are however necessary; for example, the treatment of outliers and cross-experimental correlations should be more rigorous and random files that are intended to be prior files should be generated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Confidence-weighted integration of human and machine judgments for superior decision-making

Large language models (LLMs) can surpass humans in certain forecasting tasks. What role does this leave for humans in the overall decision process? One possibility is that humans, despite performing worse than LLMs, can still add value when teamed with them. A human and machine team can surpass each individual teammate when team members’ confidence is well calibrated and team members diverge in which tasks they find difficult (i.e., calibration and diversity are needed). We simplified and extended a Bayesian approach to combining judgments using a logistic regression framework that integrates confidence-weighted judgments for any number of team members. Using this straightforward method, we demonstrated its effectiveness in both image classification and neuroscience forecasting tasks. Combining human judgments with one or more machines consistently improved overall team performance. Our hope is that this simple and effective strategy for integrating the judgments of humans and machines will lead to productive collaborations.

97 MATHEMATICS AND COMPUTING↗

In situ GISAXS study of a Si-containing block copolymer under solvent vapor annealing: Effects of molecular weight and solvent vapor composition

The room-temperature solvent vapor annealing of polystyrene-b-polydimethylsiloxane (PS-b-PDMS) block copolymer films was studied in situ by grazing incidence small-angle X-ray scattering. Films of cylinder-forming PS-b-PDMS with molecular weight 16 kg/mol and 12.2 kg/mol, annealed under vapors of toluene:heptane with varying composition, exhibited swelling-ratio-dependent evolution of microdomain spacing and orientation. In a vapor made from a toluene:heptane 5:1 volumetric ratio liquid mixture, or from pure toluene, cylindrical microdomains reoriented from majority out-of-plane to in-plane during annealing, while drying led to shrinkage along the film normal and a large distortion of the hexagonal lattice of in-plane cylinders. As a result, annealing under vapor from a toluene:heptane 1:5 volumetric ratio liquid produced a non-bulk lamellar structure in the 16 kg/mol PS-b-PDMS.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Mercury Photolytic Transformation Affected by Low-Molecular-Weight Natural Organics in Water

Mechanisms by which dissolved organic matter (DOM) mediates the photochemical reduction of Hg(II) in aquatic ecosystems are not fully understood, owing to the heterogeneous nature and complex structural properties of DOM. In this work, naturally occurring aromatic compounds including salicylic, 4-hydrobenzoic, anthranilic, 4-aminobenzoic, and phthalic acid were systematically studied as surrogates for DOM in order to gain an improved mechanistic understanding of these compounds in the photoreduction of Hg(II) in water. We show that the photoreduction rates of Hg(II) are influenced not only by the substituent functional groups such as OH, NH2 and COOH on the benzene ring, but also the positioning of these functional groups on the ring structure. The Hg(II) photoreduction rate decreases in the order anthranilic acid > salicylic acid > phthalic acid according to the presence of the NH2, OH, COOH functional groups on benzoic acid. The substitution position of the functional groups affects reduction rates in the order anthranilic acid > 4-aminobenzoic acid and salicylic acid > 4-hydroxybenzoic acid. Reduction rates correlate strongly with ultraviolet (UV) absorption of these compounds and their concentrations, suggesting that the formation of organic free radicals during photolysis of these compounds is responsible for Hg(II) photoreduction. These results provide insight into the role of low-molecular-weight organic compounds and possibly DOM in Hg photoredox transformation and may thus have important implications for understanding Hg geochemical cycling in the environment.

54 ENVIRONMENTAL SCIENCES↗

Effect of warming on the degradation and production of low-molecular-weight labile organic carbon in an Arctic tundra soil

The fate of soil organic carbon (SOC) stored in the Arctic permafrost is a key concern as temperatures continue to rise in the northern hemisphere. Studies and conceptual models suggest that SOC degradation is affected by the composition of SOC, but it is unclear exactly what portions of SOC are vulnerable to rapid breakdown and what mechanisms may be controlling SOC degradation upon permafrost thaw. Here, we examine the dynamic consumption and production of labile SOC in an anoxic incubation experiment using soil samples from the active layer at the Barrow Environmental Observatory, Barrow, Alaska, USA. Free-reducing sugars, alcohols, and low-molecular-weight (LMW) organic acids were analyzed during incubation at either –2 or 8 °C for up to 240 days. Results show that simple sugar and alcohol SOC largely account for the initial rapid release of CO 2 and CH 4 through anaerobic fermentation, whereas the fermentation products, acetate and formate, are subsequently utilized as primary substrates for methanogenesis. Iron(III) reduction is correlated to acetate production and methanogenesis, suggesting its important role as an electron acceptor in tundra SOC respiration. These observations are further supported in a glucose addition experiment, in which rapid CO 2 and CH 4 production occurred concurrently with rapid production and consumption of labile organics such as acetate. However, addition of tannic acid, as a more complex organic substrate, showed little influence on the overall production of CO 2 and CH 4 and organic acids. Together our study shows that LMW labile organics in SOC control the initial rapid release of green-house gases upon warming. We thus present a conceptual framework for the labile SOC transformations and their relations to fermentation, iron reduction and methanogenesis, thereby providing the basis for improved model prediction of climate feedbacks in the Arctic.

54 ENVIRONMENTAL SCIENCES↗

Impacts of Vehicle Weight Reduction via Material Substitution on Life-Cycle Greenhouse Gas Emissions

This study examines the vehicle-cycle impacts associated with substituting lightweight materials for those currently found in light-duty passenger vehicles. We determine part-based energy use and greenhouse gas (GHG) emission ratios by collecting material substitution data from both the literature and automotive experts and evaluating that alongside known mass-based energy use and GHG emission ratios associated with material pair substitutions. Several vehicle parts, along with full vehicle systems, are examined for lightweighting via material substitution to observe the associated impact on GHG emissions. Results are contextualized by additionally examining fuel-cycle GHG reductions associated with mass reductions relative to the baseline vehicle during the use phase and also determining material pair breakeven driving distances for GHG emissions. The findings show that, while material substitution is useful in reducing vehicle weight, it often increases vehicle-cycle GHGs depending upon the material substitution pair. However, for a vehicle’s total life cycle, fuel economy benefits are greater than the increased burdens associated with the vehicle manufacturing cycle, resulting in a net total life-cycle GHG benefit. The vehicle cycle will become increasingly important in total vehicle life-cycle GHGs, since fuel-cycle GHGs will be gradually reduced as automakers ramp up vehicle efficiency to meet fuel economy standards.

Kelly, Jarod C.↗