Search NASA⌕ Search

SEARCH · Search NASA

Results for “Advanced Detector Development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

First Measurement of the E Double-polarization Observable for the γη to Κ + Σ - with CLAS & a New Forward Tagger Hodoscope for CLAS12

Establishing the excitation spectrum of the nucleon would be a key advance to further our understanding of nucleon structure and Quantum Chromodynamics (QCD). Recent theoretical advances allow predictions of the excitation spectrum of the nucleon and other nucleon properties directly from QCD in the nonperturbative regime, via numerical methods (such as Lattice QCD), complementing existing constituent quark models. There is an ongoing world programme in meson photoproduction from the nucleon, which has already led to a number of nucleon resonances being discovered and established. This advance has largely been made possible by the first accurate measurement of polarisation observables. Available data has been obtained for proton targets, whereas for a complete picture of meson photoproduction, data from the neutron must also be obtained. This is important, as nucleon resonances can have very different photo-couplings to the proton and neutron. This thesis presents the first measurement of the E double-polarisation observable for the exclusive γη → Κ + Σ - reaction using a polarised hydrogendeuterium target from the g14 run period at CLAS. Circularly polarised photons of energies between 1:1 and 2:3 GeV were used, with results shown in 200 MeV bins in E and bins of 0:4 in cosθ C.M. / Κ + . Further to this, CLAS has undergone a detector upgrade in order to facilitate electrons of up to 12 GeV from Jefferson Lab's upgraded accelerator. Essential to this, is a new system for tagging quasi-real photons by detecting electrons scattered at very small angles. My work includes significant contributions to the design, realisation and construction of a hodoscope for this forward photon tagging apparatus. Presented in this thesis is a comprehensive overview of my work in developing and constructing the scintillating hodoscope for the CLAS12 Forward Tagger.

Fleming, Jamie↗

Performance Demonstration of Self-Powered Neutron Detectors for Steady-State Reactor Operations

The irradiation testing of sensors in reactors is a crucial step towards calibrating and qualifying sensors prior to their deployment in experiments. This report details the process toward qualifying and calibrating custom-designed rhodium-based self-power neutron detectors (Rh-SPNDs) for steady-state reactor irradiations. This process serves to both demonstrate the performance capabilities of Rh-SPNDs as well as to provide experimental data for development of a sensor sensitivity model. Two designs of Rh-SPNDs were tested in various reactors to demonstrate: detection resolution in a low neutron flux environment, a delayed-response compensation technique, output linearity in a large range of neutron flux, and measurement accuracy verified with dosimetry. The detection resolution and compensation technique was demonstrated in the AGN-201m reactor at Idaho State University. The irradiation confirmed the sensors’ capability to perform steady-state operations in a low neutron flux of ~2E8 n/cm 2 -sec. Sensor output linearity coupled with the delayed-response compensation was investigated at the neutron radiography reactor at Idaho National Laboratory. A Rh-SPND was irradiated to neutron fluxes ranging from 2E8 to 2E13 n/cm2-sec range. The measured data demonstrated a wide and linear range of operation with a measured linear sensitivity of 1.0129 ×10 -13 A/W with a correlation-squared value of r 2 =0.9927. The measurement accuracy was investigated at the Advanced Test Reactor Critical reactor. The SPNDs were inserted into a test vehicle with collocated flux wires. Two irradiations with different flux levels were performed, and the SPNDs relative measurement between the two irradiations was calculated to be 1.2613 ± 0.0153 for the small SPND design and 1.1809 ± 0.0108 for the large SPND design. Both SPND measurements fell between the co-axial dosimetry result, which reported 1.218 ± 0.047. Additionally, the preliminary MCNP model for calculating SPND sensitivity was developed in parallel to this work. Modeled neutron spectrum with measured magnitude was used for inputs to determine the simulated SPND output. The results showed an overestimation of signal strength by a factor of 5, which was expected because of model simplification. This leads to future modeling work to account for signal losses from additional physical properties, including high temperature environments for FY-21.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced high-performance large diameter Cs 2 HfCl 6 (CHC) and mixed halides scintillator

This paper reports on successful growth and performance evaluation of two large diameter Cs 2 HfCl 6 (CHC) and Cs 2 HfCl 4 Br 2 (CHCB), both recently developed scintillator crystals. The discovery of Cs 2 HfCl 6 (CHC) as a scintillator has lately generated much interest in this material and its family, which belongs to the K 2 PtCl 6 cubic crystal structure. CHC is an intrinsic scintillator that is non-hygroscopic (slightly deliquescent, i.e., slightly moisture sensitive but does not deteriorate much when left in air), has no self-radioactivity, provides excellent energy resolution, and has excellent non-proportionality. CHC has a moderate density of 3.9 g/cm 3 and an effective atomic number of 58. Reported in this paper are transparent crack-free single crystal CHC and CHCB boules of one inch in diameter, both grown using the vertical Bridgman method. Samples retrieved from the boules, sized 23 mm × 30 mm and 23 mm × 26 mm, respectively, are characterized for their optical and scintillation properties. Energy resolutions of 3.5% and 3.7% (FWHM) at 662 keV, respectively, are reported. Light yields of 23,000 ph/MeV and 20,000 ph/MeV have been calculated for the large diameter CHC and CHCB crystals, respectively. Results comparable to previously reported results for smaller crystals have been obtained. Studies on decay time, non-proportionality, as well as detector characterization are also reported.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultra-High Vacuum Outgassing Characterization of Thermally Processed Low-Carbon Steel for Advanced Particle Accelerator and Gravitational Wave Detector Applications

This dissertation investigated AISI 1020 low-carbon steel as an alternative vacuum chamber material to conventional stainless steel for ultra-high vacuum (UHV) and extreme-high vacuum (XHV) applications. After a 400 °C/48 h bake, AISI 1020 tube chambers achieved a hydrogen outgassing rate of 2.4 × 10¿¹6 Torr·L·s¿¹·cm¿², approximately 2,300 times lower than the prebaked 316L stainless-steel comparator, among the lowest hydrogen outgassing rates ever reported for an uncoated metallic vacuum chamber. Bare and magnetite-coated AISI 1020 chambers were then compared using throughput and rate-of-rise methods. The magnetite coating yielded 5× lower water outgassing at room temperature, but this advantage disappeared after 80 °C baking. After full thermal conditioning (400 °C/48 h prebake followed by 150 °C/96 h and 200 °C/110 h), bare steel achieved 25× lower hydrogen outgassing than the magnetite-coated chamber (9.6 × 10¿¹6 Torr·L·s¿¹·cm¿²) and >99% H2 purity with carbon species below RGA detection. Monte Carlo molecular flow simulations of a CEBAF photogun beamline (96 scenarios) showed that replacing 304L stainless steel with AISI 1020 reduces equilibrium H2 pressure by a factor of 833; a single 304L electrode contributes 98.8% of the gas load despite occupying only 9.1% of the internal surface area. A 500-m Einstein Telescope beampipe screening showed that corrugated bellows contribute 18% of the gas load from only 0.7% of the surface area. A five-model adsorption isotherm framework applied to 22 pumpdown datasets (164 fits with AR(1)-GLS correction) established that the experimental protocol, not the material, controls isotherm identifiability: Dubinin–Radushkevich wins isothermal pipe pumpdowns; Langmuir wins thermally dominated chamber bakes. Cross-dataset joint fitting of the AISI 1020 pipe pumpdowns yielded an H2 diffusion activation energy Ed = 7.24 ± 1.28 kcal·mol¿¹, consistent with trap dominated diffusion in commercial low-carbon steels. Two companion innovations were developed: a Variable Conductance Device (VCD, patent pending IDF-00723) for XHV outgassing measurement, and VacuumDesignerPro (VDP), a MATLAB-based design tool validated against LIGO benchmarks.

Al-Allaq, Aiman H [Old Dominion University]↗

Pyroelectric detectors

The multi-agency, long-term Global Change programs, and specifically NASA's Earth Observing system, will require some new and advanced photon detector technology which must be specifically tailored for long-term stability, broad spectral range, cooling constraints, and other parameters. Whereas MCT and GaAs alloy based photovoltaic detectors and detector arrays reach most impressive results to wavelengths as long as 12 microns when cooled to below 70 K, other materials, such as ferroelectrics and pyroelectrics, appear to offer special opportunities beyond 12 microns and above 70 K. These materials have found very broad use in a wide variety of room temperature applications. Little is known about these classes of materials at sub-room temperatures and no photon detector results have been reported. From the limited information available, researchers conclude that the room temperature values of D asterisk greater than or equal to 10(exp 9) cm Hz(exp 1/2)/W may be improved by one to two orders of magnitude upon cooling to temperatures around 70 K. Improvements of up to one order of magnitude appear feasible for temperatures achievable by passive cooling. The flat detector response over a wavelength range reaching from the visible to beyond 50 microns, which is an intrinsic advantage of bolometric devices, makes for easy calibration. The fact that these materials have been developed for reduced temperature applications makes ferro- and pyroelectric materials most attractive candidates for serious exploration.

Haller, Eugene E.↗

The conversion of CESR to operate as the Test Accelerator, CesrTA. Part 3: Electron cloud diagnostics

Cornell's electron/positron storage ring (CESR) was modified over a series of accelerator shutdowns beginning in May 2008, which substantially improves its capability for research and development for particle accelerators. CESR's energy span from 1.8 to 5.6 GeV with both electrons and positrons makes it ideal for the study of a wide spectrum of accelerator physics issues and instrumentation related to present light sources and future lepton damping rings. Additionally a number of these are also relevant for the beam physics of proton accelerators. This paper is the third in a series of four describing the conversion of CESR to the test accelerator, CESRTA. The first two papers discuss the overall plan for the conversion of the storage ring to an instrument capable of studying advanced accelerator physics issues [1] and the details of the vacuum system upgrades [2]. This paper focuses on the necessary development of new instrumentation, situated in four dedicated experimental regions, capable of studying such phenomena as electron clouds (ECs) and methods to mitigate EC effects. The fourth paper in this series describes the vacuum system modifications of the superconducting wigglers to accommodate the diagnostic instrumentation for the study of EC behavior within wigglers. Lastly, while the initial studies of CESRTA focused on questions related to the International Linear Collider damping ring design, CESRTA is a very versatile storage ring, capable of studying a wide range of accelerator physics and instrumentation questions.

43 PARTICLE ACCELERATORS↗

Synthesis Study on Transitions in Signal Infrastructure and Control Algorithms for Connected and Automated Transportation

Documenting existing state of practice is an initial step in developing future control infrastructure to be co-deployed for heterogeneous mix of connected and automated vehicles with human drivers while leveraging benefits to safety, congestion, and energy. With advances in information technology and extensive deployment of connected and automated vehicle technology anticipated over the coming decades, cities globally are making efforts to plan and prepare for these transitions. CAVs not only offer opportunities to improve transportation systems through enhanced safety and efficient operations of vehicles. There are also significant needs in terms of exploring how best to leverage vehicle-to-vehicle (V2V) technology, vehicle-to-infrastructure (V2I) technology and vehicle-to-everything (V2X) technology. Both Connected Vehicle (CV) and Connected and Automated Vehicle (CAV) paradigms feature bi-directional connectivity and share similar applications in terms of signal control algorithm and infrastructure implementation. The discussion in our synthesis study assumes the CAV/CV context where connectivity exists with or without automated vehicles. Our synthesis study explores the current state of signal control algorithms and infrastructure, reports the completed and newly proposed CV/CAV deployment studies regarding signal control schemes, reviews the deployment costs for CAV/AV signal infrastructure, and concludes with a discussion on the opportunities such as detector free signal control schemes and dynamic performance management for intersections, and challenges such as dependency on market adaptation and the need to build a fault-tolerant signal system deployment in a CAV/CV environment. The study will serve as an initial critical assessment of existing signal control infrastructure (devices, control instruments, and firmware) and control schemes (actuated, adaptive, and coordinated-green wave). Also, the report will help to identify the future needs for the signal infrastructure to act as the nervous system for urban transportation networks, providing not only signaling, but also observability, surveillance, and measurement capacity. The discussion of the opportunities space includes network optimization and control theory perspectives, and the current states of observability for key system parameters (what can be detected, how frequently can it be reported) as well as controllability of dynamic parameters (this includes adjusting not only the signal phase and timing, but also the ability to alter vehicle trajectories through information or direct control). The perspective of observability and controllability of the dynamic systems provides an appropriate lens to discuss future directions as CAV/CV become more prevalent in the future.

33 ADVANCED PROPULSION SYSTEMS↗

Ultrafast radiographic imaging and tracking: An overview of instruments, methods, data, and applications

Ultrafast radiographic imaging and tracking (U-RadIT) use state-of-the-art ionizing particle and light sources to experimentally study sub-nanosecond transients or dynamic processes in physics, chemistry, biology, geology, materials science and other fields. These processes are fundamental to modern technologies and applications, such as nuclear fusion energy, advanced manufacturing, communication, and green transportation, which often involve one mole or more atoms and elementary particles, and thus are challenging to compute by using the first principles of quantum physics or other forward models. One of the central problems in U-RadIT is to optimize information yield through, e.g. high-luminosity X-ray and particle sources, efficient imaging and tracking detectors, novel methods to collect data, and large-bandwidth online and offline data processing, regulated by the underlying physics, statistics, and computing power. We review and highlight recent progress in: (a.) Detectors such as high-speed complementary metal-oxide semiconductor (CMOS) cameras, hybrid pixelated array detectors integrated with Timepix4 and other application-specific integrated circuits (ASICs), and digital photon detectors; (b.) U-RadIT modalities such as dynamic phase contrast imaging, dynamic diffractive imaging, and four-dimensional (4D) particle tracking; (c.) U-RadIT data and algorithms such as neural networks and machine learning, and (d.) Applications in ultrafast dynamic material science using XFELs, synchrotrons and laser-driven sources. Hardware-centric approaches to U-RadIT optimization are constrained by detector material properties, low signal-to-noise ratio, high cost and long development cycles of critical hardware components such as ASICs. Interpretation of experimental data, including comparisons with forward models, is frequently hindered by sparse measurements, model and measurement uncertainties, and noise. Alternatively, U-RadIT make increasing use of data science and machine learning algorithms, including experimental implementations of compressed sensing. Machine learning and artificial intelligence approaches, refined by physics and materials information, may also contribute significantly to data interpretation, uncertainty quantification and U-RadIT optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A statistically defined anthropomorphic software breast phantom

Purpose: Digital anthropomorphic breast phantoms have emerged in the past decade because of recent advances in 3D breast x-ray imaging techniques. Computer phantoms in the literature have incorporated power-law noise to represent glandular tissue and branching structures to represent linear components such as ducts. When power-law noise is added to those phantoms in one piece, the simulated fibroglandular tissue is distributed randomly throughout the breast, resulting in dense tissue placement that may not be observed in a real breast. The authors describe a method for enhancing an existing digital anthropomorphic breast phantom by adding binarized power-law noise to a limited area of the breast. Methods: Phantoms with (0.5 mm){sup 3} voxel size were generated using software developed by Bakic et al. Between 0% and 40% of adipose compartments in each phantom were replaced with binarized power-law noise ({beta} = 3.0) ranging from 0.1 to 0.6 volumetric glandular fraction. The phantoms were compressed to 7.5 cm thickness, then blurred using a 3 Multiplication-Sign 3 boxcar kernel and up-sampled to (0.1 mm){sup 3} voxel size using trilinear interpolation. Following interpolation, the phantoms were adjusted for volumetric glandular fraction using global thresholding. Monoenergetic phantom projections were created, including quantum noise and simulated detector blur. Texture was quantified in the simulated projections using power-spectrum analysis to estimate the power-law exponent {beta} from 25.6 Multiplication-Sign 25.6 mm{sup 2} regions of interest. Results: Phantoms were generated with total volumetric glandular fraction ranging from 3% to 24%. Values for {beta} (averaged per projection view) were found to be between 2.67 and 3.73. Thus, the range of textures of the simulated breasts covers the textures observed in clinical images. Conclusions: Using these new techniques, digital anthropomorphic breast phantoms can be generated with a variety of glandular fractions and patterns. {beta} values for this new phantom are comparable with published values for breast tissue in x-ray projection modalities. The combination of conspicuous linear structures and binarized power-law noise added to a limited area of the phantom qualitatively improves its realism.

60 APPLIED LIFE SCIENCES↗

The AMoRE: Search for neutrinoless double beta decay of {sup 100}Mo

The AMoRE (Advanced Mo-based Rare process Experiment) collaboration is using calcium molybdate ({sup dep48}Ca {sup 100}MoO{sub 4}) crystals enriched in {sup 100}Mo and depleted in {sup 48}Ca to search for neutrinoless double-beta decay (DBD) of {sup 100}Mo using at the underground laboratory in Korea. Metallic magnetic calorimeters operating a milliKelvin temperatures are used as temperature sensors to measure heat and light signals from the crystals. The simultaneous and fast detection capabilities for both phonons and photons, and their excellent energy resolution provide powerful methods for identifying DBD signals and rejecting background events, which are mainly due to random coincidences between two uncorrelated two-neutrino-double-beta decays of {sup 100}Mo. The AMoRE-Pilot experiment that is currently underway uses a 1.5 kg, five-element array of {sup dep48}Ca {sup 100}MoO{sub 4} crystals. The ultimate goal is a ∼200 kg array of crystals and a half-life sensitivity of order 10{sup 26} years, which will access the inverted hierarchy region for effective Majorana neutrino masses, i.e., 0.02 to 0.05 eV. In this talk, we present recent progress on the development of low-background calcium molybdate detectors and results from room- and milli-Kelvin temperatures. Sensitivities based on GEANT4 simulations that incorporate measured background are reported.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Advancing the Fork detector for quantitative spent nuclear fuel verification

The Fork detector is widely used by the safeguards inspectorate of the European Atomic Energy Community (EURATOM) and the International Atomic Energy Agency (IAEA) to verify spent nuclear fuel. Fork measurements are routinely performed for safeguards prior to dry storage cask loading. Additionally, spent fuel verification will be required at the facilities where encapsulation is performed for acceptance in the final repositories planned in Sweden and Finland. The use of the Fork detector as a quantitative instrument has not been prevalent due to the complexity of correlating the measured neutron and gamma ray signals with fuel inventories and operator declarations. A spent fuel data analysis module based on the ORIGEN burnup code was recently implemented to provide automated real-time analysis of Fork detector data. This module allows quantitative predictions of expected neutron count rates and gamma units as measured by the Fork detectors using safeguards declarations and available reactor operating data. This study describes field testing of the Fork data analysis module using data acquired from 339 assemblies measured during routine dry cask loading inspection campaigns in Europe. Assemblies include both uranium oxide and mixed-oxide fuel assemblies. More recent measurements of 50 spent fuel assemblies at the Swedish Central Interim Storage Facility for Spent Nuclear Fuel are also analyzed. An evaluation of uncertainties in the Fork measurement data is performed to quantify the ability of the data analysis module to verify operator declarations and to develop quantitative go/no-go criteria for safeguards verification measurements during cask loading or encapsulation operations. The goal of this approach is to provide safeguards inspectors with reliable real-time data analysis tools to rapidly identify discrepancies in operator declarations and to detect potential partial defects in spent fuel assemblies with improved reliability and minimal false positive alarms. Finally, the results are summarized, and sources and magnitudes of uncertainties are identified, and the impact of analysis uncertainties on the ability to confirm operator declarations is quantified.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of Technology for Compact Coherent Lidar

In view of the recent advances in the area of solid state and semiconductor lasers has created new possibilities for the development of compact and reliable coherent lidars for a wide range of applications. These applications include: Automated Rendezvous and Capture, wind shear and clear air turbulence detection, aircraft wake vortex detection, and automobile collision avoidance. The work performed by the UAH personnel under this Delivery Order, concentrated on design and analyses of a compact coherent lidar system capable of measuring range and velocity of hard targets, and providing air mass velocity data. The following is the scope of this work. a. Investigate various laser sources and optical signal detection configurations in support of a compact and lightweight coherent laser radar to be developed for precision range and velocity measurements of hard and fuzzy targets. Through interaction with MSFC engineers, the most suitable laser source and signal detection technique that can provide a reliable compact and lightweight laser radar design will be selected. b. Analyze and specify the coherent laser radar system configuration and assist with its optical and electronic design efforts. Develop a system design including its optical layout design. Specify all optical components and provide the general requirements of the electronic subsystems including laser beam modulator and demodulator drivers, detector electronic interface, and the signal processor. c. Perform a thorough performance analysis to predict the system measurement range and accuracy. This analysis will utilize various coherent laser radar sensitivity formulations and different target models.

Amzajerdian, Farzin↗

Near Detector Selection for Neutral Current Disappearance Search at the Short-Baseline Neutrino Program

Various short baseline neutrino experiments observe anomalies that challenge the three-flavor neutrino oscillation model, consistent with a hypothetical “sterile” neutrino that does not interact via the weak force. This poster presents a near detector event selection at the Short-Baseline Near Detector (SBND), developed for the first search for neutral current (NC) disappearance at short-baseline experiments. NC disappearance provides ``smoking gun” insight into the sterile neutrino question because NC interactions are equally sensitive to all three active neutrinos, meaning any change in the NC interaction rate between near and far detectors cannot be explained by oscillations among known flavor states. This analysis focuses on the NC1p topology, the most common NC interaction type at the Short-Baseline Neutrino (SBN) Program. NC topologies are inherently challenging due to their low light yield and the absence of an outgoing charged lepton, which complicates identification and leads to poor energy reconstruction as the outgoing neutrino carries away a large portion of the neutrino’s initial energy. This work presents an NC1p event selection at the near detector, highlighting SBND’s impressive detector capabilities, including trigger efficiency studies. Combined with a novel kinematic energy reconstruction technique leveraging the detector’s outstanding hadronic detail, this analysis establishes a robust near detector foundation to target an NC disappearance measurement consistent with the 3$+$1 sterile neutrino model. This SBND selection will soon be combined with the far detector to conduct an NC disappearance search, providing unique insight and complementary information to traditional charged current searches and advancing the SBN Program’s goal to resolve the sterile neutrino question, including 3$+$1 searches and beyond.

Nicole Pallat, Nicole Pallat [Minnesota U.] (ORCID↗

The ATIC Long Duration Balloon Project

Long Duration Balloon (LDB) scientific experiments, launched to circumnavigate the south pole over Antarctica, have particular advantages compared to Shuttle or other Low Earth Orbit (LEO) missions in terms of cost, weight, scientific 'duty factor' and work force development. The Advanced Thin Ionization Calorimeter (ATIC) cosmic ray astrophysics experiment is a good example of a university-based project that takes full advantage of current LDB capability. The ATIC experiment is currently being prepared for its first LDB science flight that will investigate the charge composition and energy spectra of primary cosmic rays over the energy range from about 10(exp 10) to 10(exp 14) eV. The instrument is built around a fully active, Bismuth Germanate (BGO) ionization calorimeter to measure the energy deposited by the cascades formed by particles interacting in a thick carbon target. A highly segmented silicon matrix, located above the target, provides good incident charge resolution plus rejection of the 'backscattered' particles from the interaction. Trajectory reconstruction is based on the cascade profile in the BGO calorimeter, plus information from the three pairs of scintillator hodoscope layers in the target section above it. A full evaluation of the experiment was performed during a test flight occurring between 28 December 2000 and 13 January 2001 where ATIC was carried to an altitude of approx. 37 km above Antarctica by an approx. 850,000 cu m helium filled balloon for one circumnavigation of the continent. All systems behaved well, the detectors performed as expected, more than 43 gigabytes of engineering and cosmic ray event data was returned and these data are now undergoing preliminary data analysis. During the coming 2002-2003 Antarctica summer season, we are preparing for a ATIC science flight with approx. 15 to 30 days of continuous data collection in the near-space environment of LDB float altitudes.

Guzik, T. G.↗

A High Temperature-Tolerant and Radiation-Resistant In-Core Neutron Sensor for Advanced Reactors. Final report

The objectives of this project are to develop a small and reliable gallium nitride (GaN) neutron sensor that is capable of withstanding high neutron fluence and high temperature, isolating gamma background, and operating in a wide dynamic range. The first objective will be the understanding of the fundamental materials properties and electronic response of a GaN semiconductor materials and device in an environment of high temperature and intense neutron field. To achieve such goal, an in-situ study of electronic properties of GaN device such as I-V, leakage current, and charge collection efficiency (CCE) in high temperature using an external neutron beam will be designed and implemented. We will also perform in-core irradiation of GaN up to the highest yet fast neutron fluence and an off-line performance evaluation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Science Instruments for the Advanced X-Ray Astrophysics Facility (AXAF)

The AXAF program has undergone major changes since the Announcement of Opportunity was extended by NASA Headquarters in 1983. The Science Instruments (SI's) for AXAF have also experienced several design changes since they were competitively selected in 1985. Moreover, two separate complementary missions are now being baselined for AXAF; one is designated AXAF-I for imaging and will include the high precision Wolter type I optics, and the other is called AXAF-S for spectroscopy. The resulting less-costly AXAF will still be superior to any previous x-ray observatories. Both missions continue to be managed. AXAF-I contains two focal plane SI's, the High Resolution Camera (HRC), and the AXAF Charge-Coupled Device (CCD) imaging spectrometer (ACIS), as well as the High-Energy Transmission Grating Spectrometer (HETGS) and the Low-Energy Transmission Grating Spectrometer (LETGS). Optics/Cryogenics Division (BECD). AXAF-S features only one focal plane SI, the X-Ray Spectrometer (XRS). The grazing incidence mirrors for this mission are mainly to provide a large collecting area and to concentrate these x-ray photons onto the XRS detector. Precise focusing, although preferred, is of secondary importance. Nested conical foil mirrors are currently baselined; however, replicated imaging optics are being evaluated for collecting efficiency and cost. AXAF-S is scheduled to be launched in late 1999. It has been designated as an MSFC in-house project. In addition to overall management, MSFC is fully responsible for the design, development, integration, and test of the complete AXAF-S observatory, including the XRS which will be furnished by the Goddard Space Flight Center (GSFC). Together, AXAF-I and AXAF-S constitute the third of NASA's series of Great Observatories, joining the Hubble space telescope (HST) and the Gamma-Ray Observatory (GRO) which are already operational. The develop- ment, launch, and operation of the Space InfraRed Telescope Facility (SIRTF) will follow later to complete the Great Observatory series. This paper summarizes the impact these changes have had on the SI's.

Carl E Winkler↗

Sci—Fri PM: Dosimetry—01: Radiation-induced refraction artefacts in the optical CT readout of polymer gel dosimeters

Polymer gel dosimeters (PGDs) are a desirable tool for the verification of advanced radiotherapy treatments. Fully 3D, deformable, and tissue-equivalent, the PGD polymerizes wherever it absorbs dose. To measure the dose absorbed by a PGD, optical computed tomography (CT) can be used to evaluate, in full 3D, the opacity distribution that coincides with polymerization. In addition to an increase in opacity with dose, an increase in refractive index (RI) is also known to occur in irradiated polymer gels. The increase in RI is slight and was previously assumed insignificant. This work reveals the effects that radiation-induced RI changes can have on the optical CT readout of PGDs. A fan-beam optical CT scanner was used to image a cylindrical PGD irradiated by a pair of 3×3 cm{sup 2}, 6 MV photon beams in an orthogonal arrangement. Investigative scans were performed to evaluate refraction errors occurring: i) within the plane, and ii) out of the plane of the fan-beam. In-plane refraction was shown to cause distinct streaking artefacts along dose gradients (i.e. RI gradients) due to higher intensity rays being refracted into more opaque regions. Out-of-plane refraction was shown to produce severe, widespread artefacts due to rays missing the detector array. An iterative Savitzky-Golay filtering technique was developed to reduce both types of artefacts by specifically targeting structured errors in sinogram space. Results introduce a new category of imaging artefacts to be aware of when using optical CT for PGD readout.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies in pulse shape discrimination for an optimized ASIC design

The continued advancements of Silicon Photomultipliers (SiPMs) have made them viable photosensors for low recoil energy Pulse Shape Discrimination (PSD) between fast neutron and gamma interactions when coupled to an appropriate scintillator. At the same time, the large number of channels in a typical array calls for the development of low-cost and low-power electronics. A custom integrated circuit (ASIC) is an ideal solution for this purpose. To assess the requirements for such an ASIC, studies were performed using two scintillators, Stilbene and EJ-276, coupled to a 6 x 6 mm SiPM from Onsemi. We demonstrate that both scintillators are viable for performing PSD for interaction energies from 100 keV to several MeV while optimizing the integration periods used in the PSD metric. These measurements inform the design parameters of the ASIC under development.

Si-PMTs↗