Search NASA⌕ Search

SEARCH · Search NASA

Results for “Analyzer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Recent developments in thermal radiation system analyzer (Trasys)

Changes in the thermal radiation analyzer system (TRASYS) computer program are discussed. New capabilities were added while keeping intact the same data input structure. An overview of the program structure and general capabilities is given. Where appropriate, assessments are made of new features. The application of TRASYS peripheral programs and the importance they have in developing a totally integrated thermal analysis system are discussed. Form factor computations times were reduced approximately 40 percent, and the longer flux runs were reduced 50 percent when shadow tables were used.

Vogt, R. A.↗

Automating a residual gas analyzer

A residual gas analyzer (RGA), a device for measuring the amounts and species of various gases present in a vacuum system is discussed. In a recent update of the RGA, it was shown that the use of microprocessors could revolutionize data acquisition and data reduction. This revolution is exemplified by the Inficon 1Q200 RGA which was selected to meet the needs of this update. The Inficon RGA and the Zilog microcomputer were interfaced in order the receive and format the digital data from the RGA. This automated approach is discussed in detail.

Petrie, W. F.↗

The Retarding Potential Analyzer for Dynamics Explorer-B

The Retarding Potential Analyzer for Dynamics Explorer B measures the bulk ion velocity in the direction of the spacecraft motion, the constituent ion concentrations and the ion temperature along the satellite path. These parameters are derived from a least squares fit to the ion number flux versus energy curve obtained by sweeping or stepping the voltage applied to the internal retarding grids of the RPA. In addition, the spectral characteristics of irregularities in the total ion concentration are determined by high time resolution measurements and by use of a comb filter. These data are obtained from a separate wide aperture-sensor.

Hanson, W. B.↗

Non-mass-analyzed ion implantation from a solid phosphorus source

A phosphorus ion beam, extracted from a Freeman ion source charged with elemental phosphorus, has been investigated for use in solar cell fabrication. Mass spectroscopy of the beam indicates the absence of both minority-carrier lifetime degrading impurities and hydrogen. The ion beam, without mass analysis, was used for ion implantation of solar cells, and performance for all cells was found to be equivalent to mass-analyzed controls.

Spitzer, M. B.↗

The solar wind interaction with Mars as seen by the Viking retarding potential analyzers

Both energy spectra and continuous monitoring periods of the total flux above 15 eV are available, from Viking retarding potential analyzer measurements of electron fluxes not exceeding 75 eV out to 16,000 km above the Mars surface. Although the mean electron current at energies above 15 eV increases monotonically by almost two orders of magnitude from 9000 to 700 km in Viking 1 data, no clear signature of the bow shock is seen. Total current wave power shows a peak near 1700 km altitude. It is suggested that there may be a highly turbulent shock structure masking a clear signature of the bow shock in the time-averaged data, and it is concluded that the interaction model consistent with the bow shock at 1700 km, together with ionosphere measurements, indicates a permanent magnetic field able to stand off the solar wind during the Viking 1 entry.

Cragin, B. L.↗

Microprocessor-Based Neural-Pulse-Wave Analyzer

Microprocessor-based system analyzes amplitudes and rise times of neural waveforms. Displaying histograms of measured parameters helps researchers determine how many nerves contribute to signal and specify waveform characteristics of each. Results are improved noise rejection, full or partial separation of overlapping peaks, and isolation and identification of related peaks in different histograms. 2

Kojima, G. K.↗

FORTRAN Static Source Code Analyzer

FORTRAN Static Source Code Analyzer program, SAP (DEC VAX version), automatically gathers statistics on occurrences of statements and structures within FORTRAN program and provides reports of those statistics. Provisions made for weighting each statistic and provide an overall figure of complexity.

Merwarth, P.↗

The FORTRAN static source code analyzer program (SAP) system description

A source code analyzer program (SAP) designed to assist personnel in conducting studies of FORTRAN programs is described. The SAP scans FORTRAN source code and produces reports that present statistics and measures of statements and structures that make up a module. The processing performed by SAP and of the routines, COMMON blocks, and files used by SAP are described. The system generation procedure for SAP is also presented.

Decker, W.↗

The FORTRAN static source code analyzer program (SAP) user's guide, revision 1

The FORTRAN Static Source Code Analyzer Program (SAP) User's Guide (Revision 1) is presented. SAP is a software tool designed to assist Software Engineering Laboratory (SEL) personnel in conducting studies of FORTRAN programs. SAP scans FORTRAN source code and produces reports that present statistics and measures of statements and structures that make up a module. This document is a revision of the previous SAP user's guide, Computer Sciences Corporation document CSC/TM-78/6045. SAP Revision 1 is the result of program modifications to provide several new reports, additional complexity analysis, and recognition of all statements described in the FORTRAN 77 standard. This document provides instructions for operating SAP and contains information useful in interpreting SAP output.

Decker, W.↗

High-pressure liquid chromatography: A brief introduction and its application in analyzing the degradation of a C-ether (Thio-ether) liquid lubricant

The general principles of classical liquid chromatography and high pressure liquid chromatography (HPLC) are reviewed, and their advantages and disadvantages are compared. Several chromatographic techniques are reviewed, and the analytical separation of a C-ether liquid lubricant by each technique is illustrated. A practical application of HPLC is then demonstrated by analyzing a degraded C-ether liquid lubricant from full scale, high temperature bearing tests.

Source record↗

Planar ion trap (retarding potential analyzer) experiment for atmosphere explorer

The retarding potential analyzer and drift meter were carried aboard all three Atmosphere Explorer spacecraft. These instruments measure the total thermal ion concentration and temperature, the bulk thermal ion velocity vector and some limited properties of the relative abundance of H(+), He(+), O(+) and molecular ions. These instruments functioned with no internal failures on all the spacecraft. On AE-E there existed some evidence for external surface contamination that damaged the integrity of the RPA sweep grids. This led to some difficulties in data reduction and interpretation that did not prove to be a disastrous problem. The AE-D spacecraft functioned for only a few months before it re-entered. During this time the satellite suffered from a nutation about the spin axis of about + or - 2 deg. This 2 deg modulation was superimposed upon the ion drift meter horizontal ion arrival angle output requiring the employment of filtering techniques to retrieve the real data.

Hanson, W. B.↗

Multiwavelength analyzer for the determination of diffusion lengths

The minority carrier diffusion length Ln in the base or substrate region is an important parameter which governs a solar cell's performance. The present investigation is concerned with the development of a multiwavelength analyzer (MWA) technique for the nondestructive spatial testing of polycrystalline solar cells. The MWA method is based on the utilization of the short-circuit current generated by two or more light-emitting diodes (LEDs) operating at different wavelengths and modulated 180 deg out-of-phase. For a determination of Ln by the MWA technique, it is necessary to know the value of the absorption coefficient.

Stafsudd, O. M.↗

Software Design Analyzer System

CRISP80 software design analyzer system a set of programs that supports top-down, hierarchic, modular structured design, and programing methodologies. CRISP80 allows for expression of design as picture of program.

Tausworthe, R. C.↗

Hubble space telescope component qualification utilizing a residual gas analyzer

An approach is described for integrating an automated residual gas analyzer (RGA) into the thermal vacuum outgas process. The RGA has the capability of detailed analysis over a 200 amu range with monitoring of each peak as the test progresses. The NASA criterion of either a 50% reduction of each peak over 44 amu or less than an 0.1% amplitude of the 28 amu base peak for all amu's above 44 amu is satisfied. A computer sorts, reports which peaks do not satisfy the criterion, and reports test completion. The computer plots amplitudes of all the peaks from 1 amu through 200 amu for each scan. This RGA real time approach is unique in that it provides sufficient detail to highlight a problem as it occurs. By comparison, a quartz crystal microbalance (QCM) or a thermoelectric quartz crystal microbalance (TQCM) indicates to the operator when changes occur, but not what has happened. Optical witness samples indicate whether a test was satisfactory within a few days after the test was completed.

Westfall, A. H.↗

The dayside Venus ionosphere. I - Pioneer-Venus retarding potential analyzer experimental observations

The median values of the principal ionospheric quantities of the Venus dayside ionosphere are presented. The values are derived from the quantities measured by the Pioneer-Venus orbiter retarding potential analyzer over a period of two earth years at solar cycle maximum. Quantities reported are total ion density, O(+) density, O2(+) density, sum density (NO(+) + N2(+) + CO(+)), CO2(+) density, ion temperature, electron temperature, and plasma particle pressure. The data are organized to reveal altitude, solar zenith angle, solar longitude, and latitude dependences. The O(+) density exhibits both a solar longitude and a latitude dependence which may be caused by superrotation of the thermosphere and/or ionosphere. Asymmetry between the dawn and dusk terminator regions in the behavior of other quantities is also described.

Miller, K. L.↗

Thermal, One-Dimensional Analyzer Program

Thermal, one-dimensional analyzer program enables user to predict surface temperature of fibrous, feltlike insulation exposed to some external radiant heat source or convective heating produced by aerodynamic forces. Prediction derived from readings of thermocouple embedded in material at some depth below surface. Program useful in analysis and evaluation of insulative qualities of similar or new compositions.

Patel, D. K.↗

Analyzing Static Loading of Complex Structures

Critical loading conditions determined from analysis of each structural element. Automated Thrust Structures Loads and Stresses (ATLAS) system is series of programs developed to analyze elements of complex structure under static-loading conditions. ATLAS calculates internal loads, beam-bending loads, column- and web-buckling loads, beam and panel stresses, and beam-corner stresses. Programs written in FORTRAN IV and Assembler for batch execution.

Gallear, D. C.↗

Numerical methods for analyzing electromagnetic scattering

Attenuation properties of the normal modes in an overmoded waveguide coated with a lossy material were analyzed. It is found that the low-order modes, can be significantly attenuated even with a thin layer of coating if the coating material is not too lossy. A thinner layer of coating is required for large attenuation of the low-order modes if the coating material is magnetic rather than dielectric. The Radar Cross Section (RCS) from an uncoated circular guide terminated by a perfect electric conductor was calculated and compared with available experimental data. It is confirmed that the interior irradiation contributes to the RCS. The equivalent-current method based on the geometrical theory of diffraction (GTD) was chosen for the calculation of the contribution from the rim diffraction. The RCS reduction from a coated circular guide terminated by a PEC are planned schemes for the experiments are included. The waveguide coated with a lossy magnetic material is suggested as a substitute for the corrugated waveguide.

Lee, S. W.↗