Search NASA⌕ Search

SEARCH · Search NASA

Results for “Angular dependence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

HX-POL - A Balloon-Bourne Hard X-Ray Polarimeter

We report on the design and estimated performance of a balloon-borne hard X-ray polarimeter called HX-POL. The experiment uses a combination of Si and Cadmium Zinc Telluride detectors to measure the polarization of 50 keV-400 keV X-rays from cosmic sources through the dependence of the angular distribution of Compton scattered photons on the polarization direction. On a one-day balloon flight, HX-POL would allow us to measure the polarization of bright Crab-like sources for polarization degrees well below 10%. On a longer (15-30 day) flight from Australia or Antarctica, HX-POL would be be able to measure the polarization of bright galactic X-ray sources down to polarization degrees of a few percent. Hard X-ray polarization measurements provide unique venues for the study of particle acceleration processes by compact objects and relativistic outflows. In this paper, we discuss the overall instrument design and performance. Furthermore, we present results from laboratory tests of the Si and CZT detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Partial scan artifact reduction (PSAR) for the assessment of cardiac perfusion in dynamic phase-correlated CT

Purpose: Cardiac CT achieves its high temporal resolution by lowering the scan range from 2{pi} to {pi} plus fan angle (partial scan). This, however, introduces CT-value variations, depending on the angular position of the {pi} range. These partial scan artifacts are of the order of a few HU and prevent the quantitative evaluation of perfusion measurements. The authors present the new algorithm partial scan artifact reduction (PSAR) that corrects a dynamic phase-correlated scan without a priori information. Methods: In general, a full scan does not suffer from partial scan artifacts since all projections in [0, 2{pi}] contribute to the data. To maintain the optimum temporal resolution and the phase correlation, PSAR creates an artificial full scan p{sub n}{sup AF} by projectionwise averaging a set of neighboring partial scans p{sub n}{sup P} from the same perfusion examination (typically N{approx_equal}30 phase-correlated partial scans distributed over 20 s and n=1,...,N). Corresponding to the angular range of each partial scan, the authors extract virtual partial scans p{sub n}{sup V} from the artificial full scan p{sub n}{sup AF}. A standard reconstruction yields the corresponding images f{sub n}{sup P}, f{sub n}{sup AF}, and f{sub n}{sup V}. Subtracting the virtual partial scan image f{sub n}{sup V} from the artificial full scan image f{sub n}{sup AF} yields an artifact image that can be used to correct the original partial scan image: f{sub n}{sup C}=f{sub n}{sup P}-f{sub n}{sup V}+f{sub n}{sup AF}, where f{sub n}{sup C} is the corrected image. Results: The authors evaluated the effects of scattered radiation on the partial scan artifacts using simulated and measured water phantoms and found a strong correlation. The PSAR algorithm has been validated with a simulated semianthropomorphic heart phantom and with measurements of a dynamic biological perfusion phantom. For the stationary phantoms, real full scans have been performed to provide theoretical reference values. The improvement in the root mean square errors between the full and the partial scans with respect to the errors between the full and the corrected scans is up to 54% for the simulations and 90% for the measurements. Conclusions: The phase-correlated data now appear accurate enough for a quantitative analysis of cardiac perfusion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-C-12A-01: Develop a Patient-Specific QA Program for Radiation Therapy with On-Board MRI

Purpose: This work describes development of the first patient-specific quality assurance (QA) program for magnetic resonance imaging guided radiation therapy (MR-IGRT). Methods: The program consisted of following components: 1) multipoint ionization chamber (IC) measurement using a 15 cm3 cubic phantom, 2) 2D stacked radiographic film dosimetry using a 30×30×20 cm3 phantom with multiple inserted ICs, 3) 3D ArcCHECK measurement with a centrally inserted IC, 4) machine delivery file verification, 5) 3D Monte-Carlo dose re-calculation with machine delivery file and phantom CT, 6) 2-head mode delivery validation in case of a malfunctioning head, and 7) independent beam-on time calculation for non-IMRT fields. Both ADCL calibrated ICs and ArcCHECK were MRI compatible. Experimental data were analyzed for the first 10 patients treated at our institution. Results: The customized phantoms allowed measuring multiple points with ICs in one delivery. Absolute IC measurements were all within 3% in all phantom geometry/shape/material combinations. Despite known uncertainty associated with film dosimetry, passing rates greater than 90% were achieved in both absolute and composite modes using TG-129 criteria. Due to the simultaneous irradiation by three radiation sources, ArcCHECK was used as a 3D relative dosimeter with angular and energy dependences uncorrected. 95–100% passing rates were obtained and the centrally inserted IC measurement assured that the overall dose normalization was within 3%. Machine delivery file verification and MC recalculated dose to the phantom results showed 98–100% passing rates, providing opportunity of moving from gamma passing rates to patient DVHbased QA metrics. Same results were obtained for the 2-head delivery mode. Manual beam-on time calculation for non-IMRT fields showed better than 5% agreement. Conclusion: We have successfully developed the first MRIGRT patient specific QA program by adopting experimental and computational dosimetry methods that were developed in the past decade for other radiation therapy modalities.

60 APPLIED LIFE SCIENCES↗

Evaluation of a real-time BeO ceramic fiber-coupled luminescence dosimetry system for dose verification of high dose rate brachytherapy

Purpose: The authors evaluate the capability of a beryllium oxide (BeO) ceramic fiber-coupled luminescence dosimeter, named radioluminescence/optically stimulated luminescence (RL/OSL) BeO FOD, for dosimetric verification of high dose rate (HDR) treatments. The RL/OSL BeO FOD is capable of RL and OSL measurements. Methods: The RL/OSL BeO FOD is able to be inserted in 6F proguide needles, used in interstitial HDR treatments. Using a custom built Perspex phantom, 6F proguide needles could be submerged in a water tank at 1 cm separations from each other. A second background fiber was required to correct for the stem effect. The stem effect, dose linearity, reproducibility, depth-dose curves, and angular and temperature dependency of the RL/OSL BeO FOD were characterised using an Ir-192 source. The RL/OSL BeO FOD was also applied to the commissioning of a 10 mm horizontal Leipzig applicator. Results: Both the RL and OSL were found to be reproducible and their percentage depth-dose curves to be in good agreement with those predicted via TG-43. A combined uncertainty of 7.9% and 10.1% (k = 1) was estimated for the RL and OSL, respectively. For the 10 mm horizontal Leipzig applicator, measured percentage depth doses were within 5% agreement of the published reference calculations. The output at the 3 mm prescription depth for a 1 Gy delivery was verified to be 0.99 ± 0.08 Gy and 1.01 ± 0.10 Gy by the RL and OSL, respectively. Conclusions: The use of the second background fiber under the current setup means that the two fibers cannot fit into a single 6F needle. Hence, use of the RL is currently not adequate for the purpose of in vivo brachytherapy dosimetry. While not real-time, the OSL is shown to be adequate for in vivo brachytherapy dosimetry.

60 APPLIED LIFE SCIENCES↗

Information encoding in the spatial correlations of entangled twin beams

The ability to use the temporal and spatial degrees of freedom of quantum states of light to encode and transmit information is crucial for a robust and efficient quantum network. In particular, the potential offered by the large dimensionality of the spatial degree of freedom remains unfulfilled, as the necessary level of control required to encode information remains elusive. We encode information in the distribution of the spatial correlations of entangled twin beams by taking advantage of their dependence on the angular spectrum of the pump needed for four-wave mixing. We show that the encoded information can only be extracted through joint spatial measurements of the twin beams and not through individual beam measurements and that the temporal quantum correlations are not modified. The ability to engineer the spatial properties of twin beams will enable high-capacity quantum networks and quantum-enhanced spatially resolved sensing and imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coherent backscattering of light in nematic liquid crystals

Multiple light scattering by director fluctuations in nematic liquid crystals is considered. A uniform director orientation is assumed to be specified by an applied magnetic field. The coherent backscattering effect, which consists in the presence of a sharp light backscattering peak, is studied. The Bethe-Salpeter equation is used to calculate the multiple scattering intensity taking into account the contributions of ladder and cyclic diagrams. An analytical expression for the angular and polarization dependences of the coherent backscattering intensity is obtained in terms of the diffusion approximation. The calculation and experimental results are compared. The developed theory is shown to qualitatively describe the elliptical shape of the backscattering cone, to explain the absence of a coherent contribution for crossed polarizations, and to calculate the relative peak height.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Method for calculating multiphoton above-threshold processes in atoms: Two-photon above-threshold ionization

The two-photon above-threshold ionization of atoms is calculated using numerical algorithms of the Pade approximation in the model-potential method with the Coulomb asymptotics. The total and differential cross sections of the above-threshold ionization of helium and alkali metal atoms by elliptically polarized radiation are presented. The dependence of the angular distribution of photoelectrons on the sign of the ellipticity of radiation (the elliptic dichroism phenomenon) is analyzed in the above-threshold frequency range.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ionization of ytterbium atoms from an excited state

The cross sections of the photoionization and the electron impact-induced ionization of Yb atoms from the excited 6s6p({sup 3}P{sub 1}) state are numerically calculated. Matrix elements are computed in multielectron relativistic and nonrelativistic approximations with allowance for the superposition of configurations and a relaxation effect. The radial part of the electron wavefunction in a continuous spectrum is calculated using the solutions to one-configuration Hartree-Fock and Dirac-Fock equations. The cross sections calculated by a relativistic method are compared to those for a nonrelativistic approximation. The ratios of the radiation reduced matrix elements and the phase shifts of the wavefunctions of a continuous spectrum calculated for the 6p {epsilon}s and 6p {sup {yields} {epsilon}}d transitions are compared to the values obtained by approximating the experimental dependences of the angular distribution of photoelectrons for the photoionization by ultraviolet radiation from an oriented excited state.

74 ATOMIC AND MOLECULAR PHYSICS↗

Polarization bremsstrahlung from a fast structural ion in a plasma

Polarization bremsstrahlung from a fast hydrogen-like ion in a plasma is calculated and analyzed in the first Born approximation with allowance for the contribution from two radiation mechanisms (channels): (i) radiation from the conversion of the electromagnetic field of the ion into a real photon by plasma electrons and (ii) radiation from the virtual excitation of the bound electron of the ion. It is shown that the intensity of the polarization bremsstrahlung generated via the second channel is sharply peaked in narrow spectral-angular ranges around the eigenfrequencies of the electron core of the fast ion and, moreover, the spectral-angular intensity distribution depends strongly on the velocity of the incident particle. The dependence of both the polarization bremsstrahlung mechanisms on the plasma parameters is investigated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Great Observatories All-Sky LIRG Survey: Herschel Image Atlas and Aperture Photometry

Far-infrared images and photometry are presented for 201 Luminous and Ultraluminous Infrared Galaxies [LIRGs: log (L{sub IR}/L{sub ⊙})=11.00--11.99, ULIRGs: log (L{sub IR}/L{sub ⊙})=12.00--12.99], in the Great Observatories All-Sky LIRG Survey (GOALS), based on observations with the Herschel Space Observatory Photodetector Array Camera and Spectrometer (PACS) and the Spectral and Photometric Imaging Receiver (SPIRE) instruments. The image atlas displays each GOALS target in the three PACS bands (70, 100, and 160 μm) and the three SPIRE bands (250, 350, and 500 μm), optimized to reveal structures at both high and low surface brightness levels, with images scaled to simplify comparison of structures in the same physical areas of ∼100 × 100 kpc{sup 2}. Flux densities of companion galaxies in merging systems are provided where possible, depending on their angular separation and the spatial resolution in each passband, along with integrated system fluxes (sum of components). This data set constitutes the imaging and photometric component of the GOALS Herschel OT1 observing program, and is complementary to atlases presented for the Hubble Space Telescope, Spitzer Space Telescope, and Chandra X-ray Observatory. Collectively, these data will enable a wide range of detailed studies of active galactic nucleus and starburst activity within the most luminous infrared galaxies in the local universe.

79 ASTRONOMY AND ASTROPHYSICS↗

THE HIGHEST-ENERGY COSMIC RAYS CANNOT BE DOMINANTLY PROTONS FROM STEADY SOURCES

The bulk of observed ultrahigh-energy cosmic rays could be light or heavier elements and originate from an either steady or transient population of sources. This leaves us with four general categories of sources. Energetic requirements set a lower limit on single-source luminosities, while the distribution of particle arrival directions in the sky sets a lower limit on the source number density. The latter constraint depends on the angular smearing in the skymap due to the magnetic deflections of the charged particles during their propagation from the source to the Earth. We contrast these limits with the luminosity functions from surveys of existing luminous steady objects in the nearby universe and strongly constrain one of the four categories of source models, namely, steady proton sources. The possibility that cosmic rays with energy >8 × 10{sup 19} eV are dominantly pure protons coming from steady sources is excluded at 95% confidence level, under the safe assumption that protons experience less than 30° magnetic deflection on flight.

79 ASTRONOMY AND ASTROPHYSICS↗

A Challenge for Discrimination of Color-Singlet versus Color-Octet Quarkonium Production

The precise mechanism for production of quarkonium at hadron colliders is still an open question. Within non-relativistic quantum chromodynamics, quarkonium production cross sections can be factorized into short-distance, perturbative contributions and universal, non-perturbative, long-distance matrix elements, and then summed over quantum numbers of the heavy quark pair. In principle, at short-distances, the heavy quark pair can be either in a color-singlet or color-octet state, and it is desirable to establish the relative contributions to compare with data and to make predictions in different experimental environments. From the explicit form of the lowest-order perturbative matrix elements for color-singlet and color-octet production, we show that the structure of the optimal observable for discrimination on phase space, the likelihood ratio, has strong dependence on the angular momentum state of the heavy quark pair. This presents an obstruction for construction of a single, robust discrimination observable that can be applied to production of an arbitrary quarkonium state.

Larkoski, Andrew↗

Resonance scattering from absorbing spheres.

Electromagnetic scattering from adsorbing spheres near resonances calculated from extinction efficiency factor and angular scattering function dependence on refractive index

RESONANCE SCATTERING↗

Use of cross-correlation measurements to investigate noise generating regions of a real jet engine and a model jet

Cross-correlations are reported of the jet static pressure fluctuations (as measured with a B and K microphone fitted with a nose cone), with the far-field radiated sound pressure. These measurements were made for various probe positions and a large number of far-field positions (at various angles). In addition, the tests were run for a number of different jet exit velocities. The measured, normalized cross-correlation functions vary between 0.004 and 0.155. These values depend upon the angular position of the far-field microphone, the jet exit Mach number, and the position of the probe. In addition, the cross-correlation technique was employed to study the symmetry of the far-field radiated sound about the jet axis. Third-octave analyses of both the probe signal and the far-field radiated sound were made. This is the first time correlation measurements have been made on a jet engine. In addition, a report is given on an extensive noise survey of a model jet. The correlations are related to sound source functions and jet source regions are discussed.

Meecham, W. C.↗

Classical trajectory study of the K + CH3I reaction

Potential surfaces for the system K+IR were considered, taking into account a covalent surface, an ionic surface, the overall potential, and a comparison of a modified Bunker-Blais and a hybrid covalent-ionic potential of the electron-jump type. The Lagrange equations were solved as a system of second-order differential equations. The impact parameter, angular, and energy dependences of the product distributions for the nonreactive, reactive, and dissociative scattering were studied.

Labudde, R. A.↗

Studies of radiative transfer in the earth's atmosphere with emphasis on the influence of the radiation budget in the joint institute for advancement of flight sciences at the NASA-Langley Research Center

Earth and solar radiation budget measurements were examined. Sensor calibration and measurement accuracy were emphasized. Past works on the earth's radiation field that must be used in reducing observations of the radiation field were reviewed. Using a finite difference radiative transfer algorithm, models of the angular and spectral dependence of the earth's radiation field were developed.

Source record↗

Oscillating two-stream and parametric decay instabilities in a weakly magnetized plasma

The paper considers the effects of a weak ambient magnetic field on the oscillating two-stream and parametric decay instabilities with emphasis on the dependence of the angular variation of the instability thresholds and growth rates on the magnetic field. A dispersion relation is derived in the limit in which the electron plasma frequency is much greater than the cyclotron frequency, and is solved for dipole and monochromatic pump spectra. The analysis shows that the presence of a magnetic field can substantially enhance thresholds and reduce growth rates for waves propagating at an oblique angle with respect to the ambient magnetic field, so that the magnetic field has a stabilizing influence on the off-parallel propagating modes.

Freund, H. P.↗