Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam Distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Improvements in Monte Carlo Simulation of Large Electron Fields

Two Monte Carlo systems, EGSnrc and Geant4, were used to calculate dose distributions in large electron fields used in radiotherapy. Source and geometry parameters were adjusted to match calculated results with measurement. Both codes were capable of accurately reproducing the measured dose distributions of the 6 electron beams available on the accelerator. Depth penetration was matched to 0.1 cm. Depth dose curves generally agreed to 2% in the build-up region, although there is an additional 2-3% experimental uncertainty in this region. Dose profiles matched to 2% at the depth of maximum dose in the central region of the beam, out to the point of the profile where the dose begins to fall rapidly. A 3%/3mm match was obtained outside the central region except for the 6 MeV beam, where dose differences reached 5%. The discrepancy observed in the bremsstrahlung tail in published results that used EGS4 is no longer evident. The different systems required different source energies, incident beam angles, thicknesses of the exit window and primary foils, and distance between the primary and secondary foil. These results underscore the requirement for an experimental benchmark of electron scatter for beam energies and foils relevant to radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

3D In Vivo Dosimetry Using Megavoltage Cone-Beam CT and EPID Dosimetry

Purpose: To develop a method that reconstructs, independently of previous (planning) information, the dose delivered to patients by combining in-room imaging with transit dose measurements during treatment. Methods and Materials: A megavoltage cone-beam CT scan of the patient anatomy was acquired with the patient in treatment position. During treatment, delivered fields were measured behind the patient with an electronic portal imaging device. The dose information in these images was back-projected through the cone-beam CT scan and used for Monte Carlo simulation of the dose distribution inside the cone-beam CT scan. Validation was performed using various phantoms for conformal and IMRT plans. Clinical applicability is shown for a head-and-neck cancer patient treated with IMRT. Results: For single IMRT beams and a seven-field IMRT step-and-shoot plan, the dose distribution was reconstructed within 3%/3mm compared with the measured or planned dose. A three-dimensional conformal plan, verified using eight point-dose measurements, resulted in a difference of 1.3 {+-} 3.3% (1 SD) compared with the reconstructed dose. For the patient case, planned and reconstructed dose distribution was within 3%/3mm for about 95% of the points within the 20% isodose line. Reconstructed mean dose values, obtained from dose-volume histograms, were within 3% of prescribed values for target volumes and normal tissues. Conclusions: We present a new method that verifies the dose delivered to a patient by combining in-room imaging with the transit dose measured during treatment. This verification procedure opens possibilities for offline adaptive radiotherapy and dose-guided radiotherapy strategies taking into account the dose distribution delivered during treatment sessions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Angular Distribution of Dimuons from Drell-Yan Production in p+Fe Interactions at 120 GeV Beam Energy

In the E906/SeaQuest Fermilab experiment, we report a measurement of the angular distributions by measuring the angular parameters $\lambda$, $\mu$, and $\nu$ of Drell-Yan dimuons produced using a 120 GeV proton beam incident on an iron target. The angular distribution in the naive Drell-Yan model does not show any $\cos2\phi$ dependency, where $\phi$ denotes the azimuthal angle of dimuons in the Collins-Soper frame. However, pion-induced Drell-Yan experiments, such as NA10 and E615, have observed a significant dependence on $\cos2\phi$. The Boer–Mulders function, a transverse momentum-dependent distribution function, represents the correlation between the transverse spin and the transverse momentum of the quark. A non-zero Boer-Mulders function or an improved higher-order Drell-Yan model considering QCD effects can produce a $\cos 2\phi$ modulation in the Drell-Yan angular distribution. To measure the angular distributions, we have used an event mixing method to construct the combin atorial background, which was then subtracted from the data to isolate the Drell-Yan signal. Following this, we corrected the detector, trigger, and reconstruction efficiencies using a doubly-iterative Bayesian Unfolding method. This iterative unfolding technique improves the response matrix based on the results of the previous unfolding step, ensuring robust convergence without exaggeration of uncertainties. The angular distributions of the dimuons were measured over the invariant mass range $5.0 < M_{\mu^+ \mu^-} < 8.0$ $GeV/c^2$, with dimuon transverse momentum $P_T < 2$ GeV/c and Feynman-x $-0.18 < x_F < 0.9$. The measured angular distributions are then compared with the QCD calculations for $p + \text{Fe}$ interactions, and proton-induced angular distribution measurements from other experiments. We have observed weak $\cos 2\phi$ modulations as a function of $P_T$. For $P_T > 1.0 \, \text{GeV}/c$, the predicted NNLO perturbative QCD value of $\nu$ is larger than what we have me asured at E906/SeaQuest. Moreover, we have not observed a strong dependence of $\nu$ on the kinematic variables, such as dimuon mass $M_{\mu^+ \mu^-}$ and Bjorken-$x$. The spin alignment of the virtual photon, $\lambda$, measured from the SeaQuest Drell-Yan $p+\text{Fe}$ data, is found to be strongly dependent on $P_T$, decreasing as $P_T$ increases. $\lambda$ also holds to the upper bound condition $\lambda < 1.0$ within the statistical uncertainty, showing a trend similar to that predicted by NNLO perturbative QCD. However, for $1.0 < P_T < 2.0 \, \text{GeV}/c$, the extracted $\lambda$ value from SeaQuest is smaller than that predicted by perturbative QCD at NNLO.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fast IMRT with narrow high energy scanned photon beams

Purpose: Since the first publications on intensity modulated radiation therapy (IMRT) in the early 1980s almost all efforts have been focused on fairly time consuming dynamic or segmental multileaf collimation. With narrow fast scanned photon beams, the flexibility and accuracy in beam shaping increases, not least in combination with fast penumbra trimming multileaf collimators. Previously, experiments have been performed with full range targets, generating a broad bremsstrahlung beam, in combination with multileaf collimators or material compensators. In the present publication, the first measurements with fast narrow high energy (50 MV) scanned photon beams are presented indicating an interesting performance increase even though some of the hardware used were suboptimal. Methods: Inverse therapy planning was used to calculate optimal scanning patterns to generate dose distributions with interesting properties for fast IMRT. To fully utilize the dose distributional advantages with scanned beams, it is necessary to use narrow high energy beams from a thin bremsstrahlung target and a powerful purging magnet capable of deflecting the transmitted electron beam away from the generated photons onto a dedicated electron collector. During the present measurements the scanning system, purging magnet, and electron collimator in the treatment head of the MM50 racetrack accelerator was used with 3-6 mm thick bremsstrahlung targets of beryllium. The dose distributions were measured with diodes in water and with EDR2 film in PMMA. Monte Carlo simulations with geant4 were used to study the influence of the electrons transmitted through the target on the photon pencil beam kernel. Results: The full width at half-maximum (FWHM) of the scanned photon beam was 34 mm measured at isocenter, below 9.5 cm of water, 1 m from the 3 mm Be bremsstrahlung target. To generate a homogeneous dose distribution in a 10 x 10 cm{sup 2} field, the authors used a spot matrix of 100 equal intensity beam spots resulting in a uniformity of collimated 80%-20% penumbra of 9 mm at a primary electron energy of 50 MeV. For the more complex cardioid shaped dose distribution, they used 270 spots, which at a pulse repetition frequency of 200 Hz is completed every 1.36 s. Conclusions: The present measurements indicate that the use of narrow scanned photon beams is a flexible and fast method to deliver advanced intensity modulated beams. Fast scanned photon IMRT should, therefore, be a very interesting modality in the delivery of biologically optimized radiation therapy with the possibility for in vivo treatment verification with PET-CT imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of Ultra Small Shock Tube for High Energy Molecular Beam Source

A molecular beam source exploiting a small shock tube is described for potential generation of high energy beam in a range of 1-5 eV without any undesirable impurities. The performance of a non-diaphragm type shock tube with an inner diameter of 2 mm was evaluated by measuring the acceleration and attenuation process of shock waves. With this shock tube installed in a molecular beam source, we measured the time-of-flight distributions of shock-heated beams, which demonstrated the ability of controlling the beam energy with the initial pressure ratio of the shock tube.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ablative Richtmyer-Meshkov Experiments

Figure 1 shows a schematic of experimental setup for nonlinear Richtmyer-Meshkov (RM) instability experiments on OMEGA. Planar 15, 30, and 50-μm-thick CH targets were driven with three UV beams using a 6-ns square pulse shape, total energy of ~0.7 kJ, and laser intensity of ~5x10 13 W/cm 2 . Initial target modulations were imposed by laser imprinting using a beam with a special 2D phase plate with modulation wavelength of ~70 microns. The timing of this beam was advanced by ~200 ps, relative to other drive beams that have regular SG distributed phase plates (DPP’s). Figure 2 shows laser beam images, with SG4 DPP, and with a special 2D DPP. Growth of target modulations was measured with x-ray radiography using uranium (~1.3 keV), samarium (~1.8 keV), and tantalum (~2.2 keV) backlighters on a framing camera with 10-μm spatial resolution and 80-ps temporal resolution. Backlighter targets were driven with 2-ns square pulse shape and intensity of ~3x10 14 W/cm 2 using seven additional UV beams. Figure 3 shows an example of measured image at 1.1 ns (near the end of RM phase) taken with 50-μm thick CH foil and tantalum backlighter. Evolution of 2D broadband modulations was observed in RM phase for all target types during a shock transit time before beginning of acceleration and subsequent RT growth. Figure 4 summarizes areal-density evolution of 2D modulation at wavelength of 70 μm for 30-μm and 50-μm thick foils and compares data with predictions of 2D hydro code DRACO. Vertical dashed lines show expected times at the end of RM phase and beginning of the RT phase for these types of foils. Blue data points and curves correspond to 30-μm thick foils, while black curves and data points are for 50-μm-thick foils. Areal density modulations grow throughout RM phase, their evolution is similar to code predictions, validating the simulations.

42 ENGINEERING↗

Characteristics of Electron Distributions Observed During Large Amplitude Whistler Wave Events in the Magnetosphere

We present a statistical study of the characteristics of electron distributions associated with large amplitude whistler waves inside the terrestrial magnetosphere using waveform capture data as an addition of the study by Kellogg et al., [2010b]. We identified three types of electron distributions observed simultaneously with the whistler waves including beam-like, beam/flattop, and anisotropic distributions. The whistlers exhibited different characteristics dependent upon the observed electron distributions. The majority of the waveforms observed in our study have f/fce < or = 0.5 and are observed primarily in the radiation belts outside the plasmapause simultaneously with anisotropic electron distributions. We also present an example waveform capture of the largest magnetic field amplitude (> or = 8 nT pk-pk) whistler wave measured in the radiation belts. The majority of the largest amplitude whistlers occur during magnetically active periods (AE > 200 nT).

Wilson, Lynn B., III↗

Status of the Spallation Neutron Source beam test facility and progress of beam dynamics studies

The Spallation Neutron Source (SNS) Beam Test Facility (BTF) supports the study of beam dynamics in the front end of a high power LINAC. The BTF combines a replica of the SNS front end, including nearly-identical ion source, RFQ and MEBT, with extensive phase space diagnostics and a FODO transport line. Diagnostic capabilities include direct measurement of 6D phase space distribution and detection of halo distributions to a sensitivity of greater than one part-per-million. The goal of on-going BTF studies is to demonstrate accurate particle-in-cell modeling of halo growth and evolution by leveraging unprecedented accuracy in the description of the initial beam distribution. This work is motivated by operational experience at the SNS, which currently operates with beam loss that cannot be described by any model. This paper summarizes progress in the BTF beam study program as well as diagnostics development and recent upgrades to the beamline configuration.

Ruisard, Kiersten↗

Motion Interplay as a Function of Patient Parameters and Spot Size in Spot Scanning Proton Therapy for Lung Cancer

Purpose: To quantify the impact of respiratory motion on the treatment of lung tumors with spot scanning proton therapy. Methods and Materials: Four-dimensional Monte Carlo simulations were used to assess the interplay effect, which results from relative motion of the tumor and the proton beam, on the dose distribution in the patient. Ten patients with varying tumor sizes (2.6-82.3 cc) and motion amplitudes (3-30 mm) were included in the study. We investigated the impact of the spot size, which varies between proton facilities, and studied single fractions and conventionally fractionated treatments. The following metrics were used in the analysis: minimum/maximum/mean dose, target dose homogeneity, and 2-year local control rate (2y-LC). Results: Respiratory motion reduces the target dose homogeneity, with the largest effects observed for the highest motion amplitudes. Smaller spot sizes (σ ≈ 3 mm) are inherently more sensitive to motion, decreasing target dose homogeneity on average by a factor 2.8 compared with a larger spot size (σ ≈ 13 mm). Using a smaller spot size to treat a tumor with 30-mm motion amplitude reduces the minimum dose to 44.7% of the prescribed dose, decreasing modeled 2y-LC from 87.0% to 2.7%, assuming a single fraction. Conventional fractionation partly mitigates this reduction, yielding a 2y-LC of 71.6%. For the large spot size, conventional fractionation increases target dose homogeneity and prevents a deterioration of 2y-LC for all patients. No correlation with tumor volume is observed. The effect on the normal lung dose distribution is minimal: observed changes in mean lung dose and lung V{sub 20} are <0.6 Gy(RBE) and <1.7%, respectively. Conclusions: For the patients in this study, 2y-LC could be preserved in the presence of interplay using a large spot size and conventional fractionation. For treatments using smaller spot sizes and/or in the delivery of single fractions, interplay effects can lead to significant deterioration of the dose distribution and lower 2y-LC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ion beam capture and charge breeding in electron cyclotron resonance ion source plasmas

Beam capture of injected ions and charge breeding in electron cyclotron resonance (ECR) charge breeder ion source plasmas has been investigated utilizing an ECR plasma modeling code, the generalized ECR ion source model, and a Monte Carlo beam capture code. Beam capturing dynamics, charge breeding in the plasma, and the extracted charged ion states are described. Optimization of ion beam energy is performed for (1) high beam capture efficiency and (2) high charge state ion beam extractions. A sample case study for ANL-ECR has been performed. Ions entering ECR ion source plasma are slowed down mostly by the background ions. Assuming Maxwellian plasma ions, maximum beam energy loss occurs when the beam velocity is around the background thermal velocity in magnitude. It is also found that beam capture location affects charge state distribution. For instance, with a majority of beam ions captured near the middle of the device higher currents for higher charge states are obtained. The beam ions captured near the entry have a higher probability of backstreaming after they are captured. For this reason, the optimum beam energy of the injected Ar{sup +} beam ions for charge breeding is generally higher than the optimum input beam energy for maximum beam energy loss.

43 PARTICLE ACCELERATORS↗

Characteristics of AlN/GaN nanowire Bragg mirror grown on (001) silicon by molecular beam epitaxy

GaN nanowires containing AlN/GaN distributed Bragg reflector (DBR) heterostructures have been grown on (001) silicon substrate by molecular beam epitaxy. A peak reflectance of 70% with normal incidence at 560 nm is derived from angle resolved reflectance measurements on the as-grown nanowire DBR array. The measured peak reflectance wavelength is significantly blue-shifted from the ideal calculated value. The discrepancy is explained by investigating the reflectance of the nanoscale DBRs with a finite difference time domain technique. Ensemble nanowire microcavities with In{sub 0.3}Ga{sub 0.7}N nanowires clad by AlN/GaN DBRs have also been characterized. Room temperature emission from the microcavity exhibits considerable linewidth narrowing compared to that measured for unclad In{sub 0.3}Ga{sub 0.7}N nanowires. The resonant emission is characterized by a peak wavelength and linewidth of 575 nm and 39 nm, respectively.

36 MATERIALS SCIENCE↗

Optimization of an electron injector for operating high-intensity polarized electron beam

In this work, the simulation and optimization of an electron injector that operates a high-intensity polarized electron beam are presented. The electron injector would provide a single-bunch electron beam at a repetition rate of 1 Hz with a bunch charge of 10 nC, kinetic energy of 400 MeV and an electron spin polarization of 85%. A direct current (DC) high-voltage photogun was employed to produce the 10 nC polarized electron beam with a kinetic energy of 350 keV, beam diameter of 1.44 cm (Gaussian distribution with σ of 0.36 cm) and full bunch length of 1.3 ns (Gaussian distribution with σ of 0.325 ns). The beam was compressed to 6 ps of RMS bunch length using one 114.24 MHz standing-wave sub-harmonic buncher, two 571.2 MHz standing-wave sub-harmonic bunchers and one 2.856 GHz traveling-wave buncher. The beam was accelerated finally to 400 MeV via eight 2.856 GHz traveling-wave Linacs. We performed the beam simulation, and the simulated results showed that the optimized RMS bunch length was 4.65 ps, RMS relative energy spread was 0.48% and normalized RMS transverse emittance was 30.13 mm · mrad at a beam energy of 400 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Payload system tradeoffs for mobile communications satellites

System level trade-offs carried out during Mobile Satellite (M-SAT) design activities are described. These trade-offs relate to the use of low level beam forming, flexible power and spectrum distribution, and selection of the number of beams to cover the service area. It is shown that antenna performance can be improved by sharing horns between beams using a low level beam forming network (BFN). Additionally, greatly increased power utilization is possible using a hybrid matrix concept to share power between beams.

Moody, H. J.↗

Electron diffraction radial distribution function analysis of amorphous boron carbide synthesized by ion beam irradiation and chemical vapor deposition

Amorphous boron carbide (a-BxC) networks consist of light elements, and their low atomic scattering factors makes structural analysis by x-ray diffraction difficult. Electron diffraction has an advantage of detecting the light elements, because of the strong interaction between the matter and electrons. In this work, we prepared a-BxC by ion beam technologies and plasma-enhanced chemical vapor deposition, and characterized their structures via atomic pair-distribution functions derived from electron diffraction intensity profiles. It was found that a pentagonal pyramid is the most favorable cluster in a-B4C generated by ion irradiation, while C—C homonuclear bonds were formed in the deposited a-B x C thin film. X-ray photoemission spectroscopy revealed that the a-BxC thin film possesses more carbon than B 4 C, which is responsible for the formation of the homonuclear bonds.

36 MATERIALS SCIENCE↗

Proton-beam driven fast ignition of inertially confined fuels: Reduction of the ignition energy by the use of two proton beams with radially shaped profiles

Fast ignition of a spherical compressed deuterium-tritium assembly induced by the energy deposition of laser-accelerated proton beams is considered. An efficient way to reduce the ignition energy consists of using a two proton beams scheme [M. Temporal, Phys Plasmas 13, 122704 (2006)]. For a uniformly compressed fuel at 500 g/cm{sup 3} irradiated by proton beams with Maxwellian energy distribution with a temperature of 4 MeV, the ignition energy is 10 kJ using only one proton beam and reduces to a total of 8 kJ with the two-beam scheme. Further reduction of the ignition energy is found by using a first beam with annular radial profile and a second beam with the uniform radial profile. It is found that the first beam causes some additional fuel compression and confinement that decrease the total beam energy required for the ignition to 6 kJ, which is 40% smaller than in the case of a single beam with uniform radial profile.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Generation of Homogeneous and Patterned Electron Beams using a Microlens Array Laser-Shaping Technique

In photocathodes the achievable electron-beam parameters are controlled by the laser used to trigger the photoemission process. Non-ideal laser distribution hampers the final beam quality. Laser inhomogeneities, for instance, can be "amplified" by space-charge force and result in fragmented electron beams. To overcome this limitation laser shaping methods are routinely employed. In the present paper we demonstrate the use of simple microlens arrays to dramatically improve the transverse uniformity. We also show that this arrangement can be used to produce transversely-patterned electron beams. Our experiments are carried out at the Argonne Wakefield Accelerator facility.

43 PARTICLE ACCELERATORS↗

Numerical Simulations of Transverse Beam Diffusion Enhancement by the Use of Electron Lens in the Tevatron Collider

Transverse beam diffusion for the Tevatron machine has been calculated using the Lifetrac code. The following effects were included: random noise (representing residual gas scattering, voltage noise in the accelerating cavities) lattice nonlinearities and beam-beam interactions. The time evolution of particle distributions with different initial amplitudes in Hamiltonian action has been simulated for 6 million turns, corresponding to a time of about 2 minutes. For each particle distribution, several cases have been considered: a single beam in storage ring mode, the collider case and the effects of a hollow electron beam collimator. The diffusion coefficient for some representative points in the amplitude space has been calculated by fitting the time evolution of delta-like particle distributions using the diffusion equation, for different machine conditions. The results confirm a strong efficiency of the electron lens as an halo diffusive enhancer, leading to diffusion coefficients which are at least a factor 10K higher than the values obtained for the collision case. This result is confirmed by the Frequency Map Analysis, which shows a clear intensification of resonance lines for particle amplitudes larger than the electron lens inner radius. If compared with past experiments, the simulations successfully reproduce the diffusion coefficients for the beam core, but still present a large discrepancy for halo particles, still under investigation.

43 PARTICLE ACCELERATORS↗