Search NASA⌕ Search

SEARCH · Search NASA

Results for “CCD Camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

A dual charge-coupled device /CCD/, astronomical spectrometer and direct imaging camera. I - Optical and detector systems

The MASCOT (MIT Astronomical Spectrometer/Camera for Optical Telescopes), an instrument capable of simultaneously performing both direct imaging and spectrometry of faint objects, is examined. An optical layout is given of the instrument which uses two CCD's mounted on the same temperature regulated detector block. Two sources of noise on the signal are discussed: (1) the CCD readout noise, which results in a constant uncertainty in the number of electrons collected from each pixel; and (2) the photon counting noise. The sensitivity of the device is limited by the sky brightness, the overall quantum efficiency, the resolution, and the readout noise of the CCD. Therefore, total system efficiency is calculated at about 15%.

Meyer, S. S.↗

DISK EVOLUTION IN OB ASSOCIATIONS: DEEP SPITZER/IRAC OBSERVATIONS OF IC 1795

We present a deep Spitzer/Infrared Array Camera (IRAC) survey of the OB association IC 1795 carried out to investigate the evolution of protoplanetary disks in regions of massive star formation. Combining Spitzer/IRAC data with Chandra/Advanced CCD Imaging Spectrometer observations, we find 289 cluster members. An additional 340 sources with an infrared excess, but without X-ray counterpart, are classified as cluster member candidates. Both surveys are complete down to stellar masses of about 1 M{sub sun}. We present pre-main-sequence isochrones computed for the first time in the Spitzer/IRAC colors. The age of the cluster, determined via the location of the Class III sources in the [3.6]-[4.5]/[3.6] color-magnitude diagram, is in the range of 3-5 Myr. As theoretically expected, we do not find any systematic variation in the spatial distribution of disks within 0.6 pc of either O-type star in the association. However, the disk fraction in IC 1795 does depend on the stellar mass: sources with masses >2 M{sub sun} have a disk fraction of {approx}20%, while lower mass objects (2-0.8 M{sub sun}) have a disk fraction of {approx}50%. This implies that disks around massive stars have a shorter dissipation timescale.

79 ASTRONOMY AND ASTROPHYSICS↗

Discovery of Soft X-Ray Emission from Io, Europa and the Io Plasma Torus

The Chandra X-ray Observatory observed the Jovian system for about 24 hours on 25-26 Nov 1999 with the Advanced CCD Imaging Spectrometer (ACIS), in support of the Galileo flyby of Io, and for about 10 hours on 18 Dec 2000 with the imaging array of the High Resolution Camera (HRC-I), in support of the Cassini flyby of Jupiter. Analysis of these data have revealed soft (0.25--2 keV) x-ray emission from the moons Io and Europa, probably Ganymede, and from the Io Plasma Torus (IPT). Bombardment by energetic (greater than 10 keV) H, O, and S ions from the region of the IPT seems the likely source of the x-ray emission from the Galilean moons. According to our estimates, fluorescent x-ray emission excited by solar x-rays is about an order of magnitude too weak even during flares from the active Sun to account for the observed x-ray flux from the IPT. Charge-exchange processes, previously invoked to explain Jupiter's x-ray aurora and cometary x-ray emission, and ion stripping by dust grains both fall by orders of magnitude. On the other hand, we calculate that bremsstrahlung emission of soft X-rays from non-thermal electrons in the few hundred to few thousand eV range accounts for roughly one third of the observed x-ray flux from the IPT. Extension of the far ultraviolet (FUV) IPT spectrum likely also contributes.

Elsner, R. F.↗

In Situ Mineralogical Analysis of Planetary Materials Using X-Ray Diffraction and X-Ray Fluorescence

Remote observations of Mars have led scientists to believe that its early climate was similar to that of the early Earth, having had abundant liquid water and a dense atmosphere. One of the most fascinating questions of recent times is whether simple bacterial life developed on Mars (as it did on the Earth) during this early element period. Analyses of SNC meteorites have broadened considerably our knowledge of the chemistry of certain types of Martian rocks, underscoring the tantalizing possibility of early hydrothermal systems and even of ancient bacterial life. Detailed analyses of SNC meteorites in Terrestrial laboratories utilize the most sophisticated organic, isotopic and microscopic techniques in existence. Indeed; it is unlikely that the key biogenic indicators used in McKay et al (ibid) could be identified by a remote instrument on the surface of Mars. As a result, it is probable that any robotic search for evidence of an ancient Martian biosphere will have as its focus the identification of key minerals in likely host rocks rather than the direct detection of organic or isotopic biomarkers. Even on a sample return mission, mineralogical screening will be utilized to choose the most likely candidate rocks. X-ray diffraction (XRD) is the only technique that can provide a direct determination of the crystal structures of the phases present within a sample. When many different crystalline phases are present, quantitative analysis is better constrained if used in conjunction with a determination of elemental composition, obtainable by X-ray fluorescence (XRF) using the same X-ray source as for XRD. For planetary surface analysis, a remote instrument combining XRD and XRF could be used for mineralogical characterization of both soils and rocks. We are designing a remote XRD/XRF instrument with this objective in mind. The instrument concept pays specific attention to constraints in sample preparation, weight, volume, power, etc. Based on the geometry of a pinhole camera (transmission geometry, flat two-dimensional detector perpendicular to the direct beam), the instrument (which we call CHEMIN, for Chemistry and Mineralogy) uses an X-ray sensitive CCD detector which will allow concurrent positional and energy-dispersive analysis of collected photons. Thus XRF (energy) and XRD (geometry) analysis of transmitted X-rays will be performed at the same time. Tests performed with single minerals and simple mixtures give promising results. Refinements of the prototype promise interpretable results on complex samples.

Sarrazin, P.↗

Wide Field Camera 3: A Powerful New Imager for the Hubble Space Telescope

Wide Field Camera 3 (WFC3) is a powerful UV/visible/near-infrared camera in development for installation into the Hubble Space Telescope during upcoming Servicing Mission 4. WFC3 provides two imaging channels. The UVIS channel incorporates a 4096 x 4096 pixel CCD focal plane with sensitivity from 200 to 1000 nm. The IR channel features a 1024 x 1024 pixel HgCdTe focal plane covering 850 to 1700 nm. We report here on the design of the instrument, the performance of its flight detectors, results of the ground test and calibration program, and the plans for the Servicing Mission installation and checkout.

Kimble, Randy↗

An Updated Model for the Effect of Atmospheric Absorption on Sounding Rockets

A very high-resolution R > 20,000 Far Ultraviolet full-disk, solar spectrograph will be launched in the Spring of 2023. This paper describes the in-flight wavelength calibration techniques and the fortuitous retrieval of Earth’s thermospheric information during the flight. Building and calibration of the Full-sun Ultraviolet Rocket Spectrograph (FURST) is currently underway. The purpose of this instrument is to obtain the highest resolution and most complete Far Ultra-Violet (FUV) spectra of the full disk Sun. This so-called "Sun-as-a-star" spectra will allow direct comparisons between our Sun and other stars measured by the Hubble Space Telescope(HST) and the upcoming James Webb Space Telescope (JWST). The Solar Physics groups at NASA Marshall Space Flight Center (MSFC) and Montana State University (MSU) have been developing the tools and procedures necessary to achieve the high spectral resolution goal. These include, among other things, improved tracking of error propagation, in-situ monitoring of the camera gain with a radioactive Fe-55 source, and the development of a simulated spectral calibration map under a noisy diagnostic-lamp signal. This mapping introduces a clocked CCD in order to obtain sub-pixel spectral resolution and overcome the Nyquist limit by about a factor of 2. Aside from the main purpose of FURST, we have been investigating the effect of absorption in the upper atmosphere at sounding-rocket altitudes (about 100-300 km). We present here an improved model of the optical depth caused by the thermospheric Oxygen cross-section and H and O self-absorption. This data-based model uses concentric spherical shells to account for the curvature of the Earth’s atmosphere and refraction. Using these calculations, we present the anticipated effect on the signal received by FURST, how that signal changes over the course of the flight-path These absorption peaks would provide wavelength fiducials at line-center that might add to in-flight calibration of the instrument. Many studies have found ways to correct for these so-called "Telluric" lines. However, it may be that these lines can in fact be a useful tool to further improve our calibration, rather than simply a nuisance to be corrected for! Finally, we discuss the inversion problem: how we could take actual flight data and back-out the atmospheric data (such as density and temperature) from any such sounding rocket flight that shows evidence of atmospheric absorption.

Nicolas Donders↗

Multi-MGy Radiation Hardened Camera for Nuclear Facilities

There is an increasing interest in developing cameras for surveillance systems to monitor nuclear facilities or nuclear waste storages. Particularly, for today's and the next generation of nuclear facilities increasing safety requirements consecutive to Fukushima Daiichi's disaster have to be considered. For some applications, radiation tolerance needs to overcome doses in the MGy(SiO{sub 2}) range whereas the most tolerant commercial or prototypes products based on solid state image sensors withstand doses up to few kGy. The objective of this work is to present the radiation hardening strategy developed by our research groups to enhance the tolerance to ionizing radiations of the various subparts of these imaging systems by working simultaneously at the component and system design levels. Developing radiation-hardened camera implies to combine several radiation-hardening strategies. In our case, we decided not to use the simplest one, the shielding approach. This approach is efficient but limits the camera miniaturization and is not compatible with its future integration in remote-handling or robotic systems. Then, the hardening-by-component strategy appears mandatory to avoid the failure of one of the camera subparts at doses lower than the MGy. Concerning the image sensor itself, the used technology is a CMOS Image Sensor (CIS) designed by ISAE team with custom pixel designs used to mitigate the total ionizing dose (TID) effects that occur well below the MGy range in classical image sensors (e.g. Charge Coupled Devices (CCD), Charge Injection Devices (CID) and classical Active Pixel Sensors (APS)), such as the complete loss of functionality, the dark current increase and the gain drop. We'll present at the conference a comparative study between these radiation-hardened pixel radiation responses with respect to conventional ones, demonstrating the efficiency of the choices made. The targeted strategy to develop the complete radiation hard camera electronics will be exposed. Another important element of the camera is the optical system that transports the image from the scene to the image sensor. This arrangement of glass-based lenses is affected by radiations through two mechanisms: the radiation induced absorption and the radiation induced refractive index changes. The first one will limit the signal to noise ratio of the image whereas the second one will directly affect the resolution of the camera. We'll present at the conference a coupled simulation/experiment study of these effects for various commercial glasses and present vulnerability study of typical optical systems to radiations at MGy doses. The last very important part of the camera is the illumination system that can be based on various technologies of emitting devices like LED, SLED or lasers. The most promising solutions for high radiation doses will be presented at the conference. In addition to this hardening-by-component approach, the global radiation tolerance of the camera can be drastically improve by working at the system level, combining innovative approaches eg. for the optical and illumination systems. We'll present at the conference the developed approach allowing to extend the camera lifetime up to the MGy dose range. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Aluminum/ammonia heat pipe gas generation and long term system impact for the Space Telescope's Wide Field Planetary Camera

In the Space Telescope's Wide Field Planetary Camera (WFPC) project, eight heat pipes (HPs) are used to remove heat from the camera's inner electronic sensors to the spacecraft's outer, cold radiator surface. For proper device functioning and maximization of the signal-to-noise ratios, the Charge Coupled Devices (CCD's) must be maintained at -95 C or lower. Thermoelectric coolers (TEC's) cool the CCD's, and heat pipes deliver each TEC's nominal six to eight watts of heat to the space radiator, which reaches an equilibrium temperature between -15 C to -70 C. An initial problem was related to the difficulty to produce gas-free aluminum/ammonia heat pipes. An investigation was, therefore, conducted to determine the cause of the gas generation and the impact of this gas on CCD cooling. In order to study the effect of gas slugs in the WFPC system, a separate HP was made. Attention is given to fabrication, testing, and heat pipe gas generation chemistry studies.

Jones, J. A.↗

Operation of the University of Hawaii 2.2M telescope on Mauna Kea

NASA's planetary astronomy program provides part of the funding for the 2.2 meter telescope. The parameters for time on the telescope are laid out. A major instrumental highlight has been the commissioning of a 256 x 256 near infrared camera which uses a Rockwell NICMOS-3 array. At the f/10 focus, image scales of 0.37 and 0.75 arcsec/pixel are available. A new, high quantum efficiency Tektronix 1024 x 1024 CCD saw first light on the telescope in 1991, and was available regularly from April 1991. Data from both of these detectors are transmitted directly to the Sun workstation for immediate analysis by the observers. The autoguider software was enhanced to permit guided tracking on objects have nonsideral motions (i.e., solar system objects).

Hall, Donald N. B.↗

Near-Infrared Hyperspectral Image Cubes of Mars during the 1999 Opposition

We used the Goddard Space Flight Center, Acousto-Optic Tunable Filter (AOTF) Camera to obtain near-IR spectral image sets of Mars over the 1.6-3.6 micron region during the April 1999 opposition. A complete image set consists of 280 images with a spectral full-width-half maximum of 10 wavenumbers (fixed in frequency), 90 images in H-band (1.55-1.80 micron), 115 images in K-band (1.95-2.50 micron) and 75 images in L-band (2.90-3.70 micron). The short-wavelength limit is set by transmission of AOTF cell and long-wavelength limit is imposed by sensitivity of PICNIC, 256x256, HgCdTe array detector. We will discuss the new array performance and provide preliminary interpretations of some of these results. These measurements were part of a 4-observatory coordinated effort whose overall objective was to assemble a photometrically calibrated, spectrally complete ground-based image cube over the visible and near-IR spectral region. To accomplish this, four observing teams conducted the investigations with instruments spanning 0.4 to 5.0 micron. The instruments and observing facilities were (a) AOTF camera at Apache Point Observatory, 3.5m, f/10, Nasymth focus (this abstract). Primary science targets included the 3 micron water-of hydration feature and CO2, H2O ice (polar regions and clouds); (b) Visible/NIR interference-filter (24 filters) camera at Lowell Observatory, 72" telescope. 430-1050 nm. Science targets were Fe(2+), Fe(3+) mineralogy and coarse grain hematite search; (c) NMSU Tortugas Mountain Observatory, 60 cm telescope, CCD photometry with same filter set as Lowell; (d) KPNO cryogenic grating/slit spectrometer (CRSP/SALLY) at KPNO 2.1 m, f/15 Cassegrain focus (see abstract by D. Glenar, et. al., this meeting). Selected wavelengths in 3-5 micron region (L, M band). Science targets included water-of-hydration feature (3-4 micron long wave extension) and sulfate mineralogy. Observers participating in this campaign included Dave Glenar, John Hillman, Gordon Bjoraker and Fred Espenak from GSFC, Nancy Chanover, Jim Murphy and A. S. MurTell from NMSU, Leslie Young from BU, Diana Blaney from JPL and Dick Joyce from KPNO.

Hillman, John J.↗

Advanced X-ray Astrophysics Facility (AXAF) science instruments

The overall AXAF program is summarized, with particular emphasis given to its science instruments. The science objectives established for AXAF are to determine the nature of celestial objects, from normal stars to quasars, to elucidate the nature of the physical processes which take place in and between astronomical objects, and to shed light on the history and evolution of the universe. Attention is given to the AXAF CCD imaging spectrometer, which is to provide spectrally and temporally resolved imaging, or, in conjunction with transmission grating, high-resolution dispersed spectral images of celestial sources. A high-resolution camera, an X-ray spectrometer, and the Bragg Crystal Spectrometer are also discussed.

Winkler, Carl E.↗

Scanning with charge-coupled devices

Results are presented of an investigation of six modes of using CCDs for searches of gamma-ray bursters, debris in geosynchronous space, satellites of asteroids, brown dwarfs, the tenth planet, comets, cometesimals, and various types of asteroids. A new discipline in astrophysics, 'scannerscopy', i.e., surveying with a CCD rather than with photography at a Schmidt telescope, is described. It uses the CCD in scanning rather than in sequencing of stare exposures as is done at most observatories, which can save telescope time and obviates the need for flat-fielding. Attention is given to the Tektronix 2048 x 2048 CCD, 38 arcmin wide, which is used to a limiting magnitude of 20.5 V. It is also shown to be successful for discovering rare and small near-earth asteroids. Possibilities with cameras on spacecraft that pass through the asteroid belt are described.

Gehrels, Tom↗

Mitigation of the Brighter-Fatter Effect in the LSST Camera

Thick, fully depleted charge-coupled devices (CCDs) are known to exhibit non-linear behavior at high signal levels due to the dynamic behavior of charges collecting in the potential wells of pixels, called the brighter-fatter effect (BFE). This particularly impacts bright calibration stars, which appear larger than their intrinsic shape, creating a flux-dependent point-spread function (PSF) that if left unmitigated, could make up a large fraction of the error budget in Stage IV weak-lensing (WL) surveys such as the Legacy Survey of Space and Time (LSST). In this paper, we analyze image measurements of flat fields and artificial stars taken at different illumination levels with the LSST Camera (LSSTCam) at SLAC National Accelerator Laboratory in order to quantify this effect in the LSST Camera before and after a previously introduced correction technique. We observe that the BFE evolves anisotropically as a function of flux due to higher-order BFEs, which violates the fundamental assumption of this correction method. We then introduce a new sampling method based on a physically motivated model to account these higher-order terms in the correction, and then we test the modified correction on both datasets. We find that the new method corrects the effect in flat fields better than it corrects the effect in artificial stars which we conclude is the result of a unmodeled curl component of the deflection field by the correction. We use these results to define a new metric for the full-well capacity of our sensors and advise image processing strategies to further limit the impact of the effect on LSST WL science pathways.

47 OTHER INSTRUMENTATION↗

Multi-waveband observations of colliding galaxies

Colliding galaxies represent a major challenge to both theorists and observers because of the large variety of phenomena which are expected to come into play during the interaction. Strong gravitational fluctuations may drive non-linear waves and instabilities throughout the stars and gas leading to enhanced star formation, nuclear activity and ultimately a mixing of the morphological components of the original galaxies. One relatively uncomplicated class of colliding galaxy where stellar waves play an important role in star formation are ring galaxies. Ring galaxies are probably formed when a companion galaxy passes through the center of a disk system driving circular waves through the disk (Lynds and Toomre 1976, Toomre 1978, Struck-Marcell 1990). Off-center collisions can generate non-circular waves and can be loosely described as banana-shaped although they may exhibit more complex forms as the waves expand into the disk. The propagation of such stellar and gaseous waves through the disk leads to enhanced star formation (e.g., Appleton and Struck-Marcell 1987a; Jeske 1986) and provides a unique probe of the response of the interstellar medium (ISM) to a propagating wave (see Appleton and Struck-Marcell 1987b). Here, the authors report results for 3 systems; the irregular ring Arp 143 (=VV 117); Wakamatsu's Seyfert ring (A0959-755; see Wakamatsu and Nishida 1987) and the brighter member of the pair of ring galaxies comprising of AM 1358-221. The most complete multi-wavelength data is for Arp 143. Optical charge coupled device (CCD) observations made with the 60 inch Palomar telescope at BV and r band, near-IR images at J (1.25 microns), H (1.65 microns) and k (2.2 microns) bands from the infrared camera (IRCAM) InSb array camera on the 3.8m United Kingdon Infrared Telescope (UKIRT) telescope and very large array (VLA) observations at 20cm in both the neutral hydrogen line and radio continuum are described. The observations of Wakamatsu's ring and AM 1358 were made only in the near-IR, and a comparison is made with available optical plate material.

Appleton, P. N.↗

Cooling the dark energy camera instrument

DECam, camera for the Dark Energy Survey (DES), is undergoing general design and component testing. For an overview see DePoy, et al in these proceedings. For a description of the imager, see Cease, et al in these proceedings. The CCD instrument will be mounted at the prime focus of the CTIO Blanco 4m telescope. The instrument temperature will be 173K with a heat load of 113W. In similar applications, cooling CCD instruments at the prime focus has been accomplished by three general methods. Liquid nitrogen reservoirs have been constructed to operate in any orientation, pulse tube cryocoolers have been used when tilt angles are limited and Joule-Thompson or Stirling cryocoolers have been used with smaller heat loads. Gifford-MacMahon cooling has been used at the Cassegrain but not at the prime focus. For DES, the combined requirements of high heat load, temperature stability, low vibration, operation in any orientation, liquid nitrogen cost and limited space available led to the design of a pumped, closed loop, circulating nitrogen system. At zenith the instrument will be twelve meters above the pump/cryocooler station. This cooling system expected to have a 10,000 hour maintenance interval. This paper will describe the engineering basis including the thermal model, unbalanced forces, cooldown time, the single and two-phase flow model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TH-C-17A-04: Shining Light On the Implementation of Cherenkov Emission in Radiation Therapy

Purpose: We hypothesize that Cherenkov emission (CE) by radiotherapy beams is correlated with radiation dose, CE detection can be maximized by a spectral shift towards the near-infrared (NIR) window of biological tissue, and in certain tissue types (ex. breast/oropharynx), it could prove superior to mega-voltage (MV) imaging. Therefore, we compare CE imaging to onboard MV imaging. Methods: Dose-CE correlation was investigated via simulation and experiment. A Monte Carlo (MC) CE simulator was designed using Geant4. Experimental phantoms include: water; tissuesimulating phantom composed of water, fat emulsion, and beef blood; plastic phantom with solid water insert. The optical spectrometry system consisted of a multi-mode optical fiber and diffraction-grating spectrometer incorporating a front/back-illuminated charge-coupled device (CCD). CdSe/ZnS quantum dots (QDs), emitting at (650±10) nm, were used to achieve NIR shift of the CE signal. CE and MV images were acquired with a complementary metal-oxide-semiconductor (CMOS) camera and an electronic portal imaging device (EPID), respectively. Results: MC and experimental studies indicate a strong linear correlation between radiation dose and CE (Pearson coefficient > 0.99). CE by an 18 MeV beam was effectively shifted towards the NIR in water and in a tissue-simulating phantom, exhibiting a 50% increase at 650 nm for QD depths of ∼3 mm. CE images exhibited relative contrast superior to EPID images by a factor of 30. Conclusion: Our work supports the potential for application of CE in radiotherapy online imaging for patient setup and treatment verification, since CE is intrinsic to the beam and non-ionizing, and QDs can be used to improve CE detectability, yielding image quality superior to MV imaging for the case of low density variability, low optical attenuation materials, such as breast or oropharyngeal cavities. Ongoing work involves microenvironment functionalization of QDs and application of multichannel spectrometry for simultaneous acquisition of dosimetric and tumor oxygenation signals. Funding received from the following organizations: Natural Sciences and Engineering Research Council of Canada, McGill University. YZ acknowledges partial support by the CREATE Medical Physics Research Training Network grant of the Natural Sciences and Engineering Research Council (Grant number: 432290)

07 ISOTOPE AND RADIATION SOURCES↗

Stellar photometry including saturated images: Results on M67 with WFPC2

The Wide Field and Planetary Camera 2 (WFPC2) on Hubble Space Telescope (HST) is providing unsurpassed imaging capabilities and supporting accurate stellar photometry over large fields of view at high angular resolution. I discuss a feature of the WFPC2 CCD systems that nominally limits the dynamic range attainable with single exposures: a 12 bit analog to digital converter that does not allow sampling of the CCD full-well depth even at the low gain (14e(sup -)/DN) setting. I demonstrate that accurate stellar photometry can be performed on stellar images that are strongly saturated. Two 40 s exposures in V and I bands on the old open cluster M67 are analyzed to demonstrate photometric capabilities with a dynamic range of over 12 mag from single exposures. New photometric results for both bright and faint objects in M67 are derived from the WFPC2 data.

Gilliland, Ronald L.↗