Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Critical cleaning agents for Di-2-ethylhexyl sebacate.

It is required that Di-2-ethylhexyl Sebacate oil, also commonly known as Dioctyl Sebacate oil, be thoroughly removed from certain metals, in this case stainless steel parts with narrow, enclosed spaces. Dioctyl Sebacate oil is a synthetic oil with a low compressibility. As such, it is ideally used for high pressure calibrations. The current method to remove the Dioctyl Sebacate from stainless steel parts with narrow, enclosed spaces is a labor-intensive, multi-step process, including a detergent clean, a deionized (DI) water rinse, and several solvent rinses, to achieve a nonvolatile residue of 0.04 mg per 50 mL rinse effluent. This study was undertaken to determine a superior detergent/solvent cleaning method for the oil to reduce cleaning time and/or the amount of detergent/solvent used. It was determined that while some detergent clean the oil off the metal better than the current procedure, using only solvents obtained the best result. In addition, it can be inferred, based on elevated temperature test results, that raising the temperature of the oil-contaminated stainless steel parts to approximately 50ÀC will provide for improved cleaning efficacy.

Hartley, Mya↗

SX Tank Farm Interim Surface Barrier Vadose Zone Monitoring

The Hanford Site, in southeastern Washington State, has 149 underground single-shell tanks to store hazardous radioactive waste. A number of these tanks and their associated infrastructure (e.g., pipelines, diversion boxes) have leaked. While some of the leaked waste has entered the groundwater, the majority still resides in the vadose zone. Corrective measures are being taken to mitigate the groundwater impacts from past leaks and spills from contaminants that still reside within the vadose zone. Washington River Protection Solutions, LLC, constructed two interim surface barriers (identified as south and north ISBs) in 2018 over the southern portion of the 241-SX Tank Farm to minimize the migration of the residual contaminants in the vadose zone. Two monitoring instrument nests were installed in 2018 and the data acquisition system was put into function in September 2019. This document summarizes the monitoring methods, the instrument calibration and installation, and the vadose zone monitoring plan for the interim barriers in the SX tank farm.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance of Compact Pulsed Thermal Imaging System for In-Service Applications. Pulsed thermal tomography nondestructive examination of additively manufactured reactor materials and components

Additive manufacturing (AM) is an emerging method for cost-efficient fabrication of complex topology nuclear reactor parts from high-strength corrosion resistance alloys, such as stainless steel and Inconel. AM of metallic structures for nuclear energy applications is currently based on laser powder bed fusion (LPBF) process, which has the capability of melting metallic powder and net shaping the structures with relatively high precision. Some of the challenges with using LPBF method for nuclear manufacturing include the possibility of introducing pores into metallic structures. Integrity of AM structures needs to be evaluated nondestructively because material flaws could lead to premature failures due to creep in high temperature nuclear reactor environment. Currently, there exist limited capabilities to evaluate actual AM structures nondestructively. Pulsed Thermography (PT) imaging provides a capability for non-destructive evaluation (NDE) of sub-surface defects in arbitrary size structures. The PT method is based on recording material surface temperature transients with infrared (IR) camera following thermal pulse delivered on material surface with flash light. The PT method has advantages for NDE of actual AM structures because the method involves one-sided non-contact measurements and fast processing of large sample areas captured in one image. The data cube of PT measurements consists of surface temperature taken at sequential time intervals T(x,y,t). Material defects can be detected either by analyzing the thermograms T(x,y,t) data cube, or by using thermal tomography (TT) algorithm to obtain 3D spatial reconstruction of thermal effusivity e(x,y,z). To reduce the cost and enable in-service NDE in spatially constrained environment, it is highly desirable to develop PT with compact and inexpensive IR camera. Following initial qualification of an AM component for deployment in a nuclear reactor, a compact PT system can also be used for in-service nondestructive evaluation (NDE) applications. However, data cube obtained with PT based on compact IR camera suffers from strong thermal noises and loss of features due to relatively low sampling rate. In this report we describe two unsupervised machine learning (ML) algorithms for enhancement of PT images obtained with compact IR camera. In one approach, we introduce Sparse Coding Discrete Cosine Transform (SC/DCT) algorithm to remove additive white Gaussian noise (AWGN) from spatial thermal effusivity reconstructions. In another approach we introduce a Spatial Temporal Denoised Thermal Source Separation (STDTSS) ML algorithm to process thermograms. The STDTSS algorithm consists of spatial and temporal denoising using Gaussian and Savitzky–Golay filtering, followed by the matrix decomposition using Principal Component Analysis (PCA), and Independent Component Analysis (ICA) to automatically detect flaws. In the work described in this report, we constructed a compact PT system using a relatively small and low-cost FLIR A65 camera, consisting on uncooled microbolometer detector. Performance of SC/DCT algorithm was demonstrated on enhancing TT images of Inconel 718 AM plate. Performance of the STDTSS methods was investigated using thermography data obtained from imaging stainless steel 316L specimens produced with LPBF method with imprinted calibrated porosity defects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Rossi Alpha Measurements – Rapid Organic (n, $\gamma$) Discrimination Detector (RAM-RODD) system capabilities

The Rossi Alpha Measurements–Rapid Organic (n, $\gamma$) Discrimination Detector (RAM-RODD) is an array organic scintillation detectors that has been optimized for use in neutron noise measurements. This report details the capability of the system including the method of energy calibration, pulse shape discrimination, and time resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Blueprint for the Milky Way’s Stellar Populations. IV. A String of Pearls—the Galactic Starburst Sequence

We continue our series of papers on phase-space distributions of stars in the Milky Way based on photometrically derived metallicities and Gaia astrometry, with a focus on the halo-disk interface in the local volume. To exploit various photometric databases, we develop a method of empirically calibrating synthetic stellar spectra based on a comparison with observations of stellar sequences and individual stars in the Sloan Digital Sky Survey, the SkyMapper Sky Survey, and the Pan-STARRS1 surveys, overcoming band-specific corrections employed in our previous work. In addition, photometric zero-point corrections are derived to provide an internally consistent photometric system with a spatially uniform metallicity zero-point. Using our phase-space diagrams, we find a remarkably narrow sequence in the rotational velocity (v $\phi$ ) versus metallicity ([Fe/H]) space for a sample of high proper-motion stars (>25 mas yr -1 ), which runs along Gaia Sausage/Enceladus (GSE) and the Splash substructures and is linked to the disk, spanning nearly 2 dex in [Fe/H]. Notably, a rapid increase of v $\phi$ from a nearly zero net rotation to ~180 km s -1 in a narrow metallicity interval (-0.6 ≲ [Fe/H] ≲ -0.4) suggests that some of these stars emerged quickly on a short gas-depletion timescale. Through measurements of a scale height and length, we argue that these stars are distinct from those heated dynamically by mergers. This chain of high proper-motion stars provides additional support for recent discoveries suggesting that a starburst took place when the young Milky Way encountered the gas-rich GSE progenitor, which eventually led to the settling of metal-enriched gas onto the disk.

79 ASTRONOMY AND ASTROPHYSICS↗

Thermally determining flow and/or heat load distribution in parallel paths

A method including obtaining calibration data for at least one sub-component in a heat transfer assembly, wherein the calibration data comprises at least one indication of coolant flow rate through the sub-component for a given surface temperature delta of the sub-component and a given heat load into said sub-component, determining a measured heat load into the sub-component, determining a measured surface temperature delta of the sub-component, and determining a coolant flow distribution in a first flow path comprising the sub-component from the calibration data according to the measured heat load and the measured surface temperature delta of the sub-component.

42 ENGINEERING↗

Thermally determining flow and/or heat load distribution in parallel paths

A method including obtaining calibration data for at least one sub-component in a heat transfer assembly, wherein the calibration data comprises at least one indication of coolant flow rate through the sub-component for a given surface temperature delta of the sub-component and a given heat load into said sub-component, determining a measured heat load into the sub-component, determining a measured surface temperature delta of the sub-component, and determining a coolant flow distribution in a first flow path comprising the sub-component from the calibration data according to the measured heat load and the measured surface temperature delta of the sub-component.

42 ENGINEERING↗

Predicting uniaxial compressive strength from empirical relationships between ultrasonic p-wave velocities, porosity, and core measurements in a potential geothermal reservoir, Snake River Plain, Idaho

Empirical, core-based, predictive correlations for the calculation of uniaxial compressive strength (UCS) were developed from compressive sonic velocity measurements (55 whole core samples) and porosity, density, and unconfined compressive tests (110 whole core samples). The samples were collected at 55 different depths in a 550 m (1800 ft) interval of core from the MH-2 borehole located in southern Idaho, USA. The western Snake River Plain is a known region of high heat flow and the borehole was drilled into a potential geothermal reservoir characterized by artesian flow of high-temperature (~140°C) fluids from fractured basalt. UCS was measured in unconfined compressive tests, density and porosity were measured using a He-pycnometer, and p-wave velocities were measured in a pressure vessel under variable confining pressures. We use correlations between density and p-wave velocity (R 2 = 0.91), UCS and porosity (R 2 = 0.78), and UCS and p-wave velocity (R 2 = 0.79) in a method to calculate calibrated UCS from wireline logs. Here, the impact of this predictive correlation is that UCS can be calculated from as little as a bulk density log when sonic logs and core are not available, greatly increasing the number of wells in which we can obtain a local UCS estimate.

15 GEOTHERMAL ENERGY↗

STAR facility tritium accountancy

The Safety and Tritium Applied Research (STAR) facility has been established to provide a laboratory infrastructure for the fusion community to study tritium science associated with the development of safe fusion energy and other technologies. STAR is a radiological facility with an administrative total tritium inventory limit of 1.5 g (14,429 Ci) [1]. Research studies with moderate tritium quantities and various radionuclides are performed in STAR. Successful operation of the STAR facility requires the ability to receive, inventory, store, dispense tritium to experiments, and to dispose of tritiated waste while accurately monitoring the tritium inventory in the facility. This paper describes tritium accountancy in the STAR facility. A primary accountancy instrument is the tritium Storage and Assay System (SAS): a system designed to receive, assay, store, and dispense tritium to experiments. Presented are the methods used to calibrate and operate the SAS. Accountancy processes utilizing the Tritium Cleanup System (TCS), and the Stack Tritium Monitoring System (STMS) are also discussed. Also presented are the equations used to quantify the amount of tritium being received into the facility, transferred to experiments, and removed from the facility. Finally, the STAR tritium accountability database is discussed. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Determining the Solubility Behavior of Kogarkoite in Simulated Nuclear Waste

Kogarkoite (Na 3 FSO 4 ) is a sparingly soluble fluoride–sulfate double salt that has been identified in high level nuclear waste sludge at the Hanford Site and, more recently, in sludge batch compilation samples at the Savannah River Site (SRS). Due to its complex dissolution behavior, which exhibits an inverse dependence on sodium ion activity, the presence of this mineral poses significant challenges to waste retrieval and processing. Incomplete dissolution during sludge washing can lead to the retention of fluoride and sulfate in the high-level waste feed, potentially causing the formation of corrosive, immiscible molten salt layers, known as "glass gall,” in vitrification melters. Current efforts to optimize flowsheet parameters and wash-water volumes are hindered by the absence of a commercially available, certified reference material, which prevents the accurate calibration of analytical methods and the verification of dissolution kinetics. To address this critical gap, this research focuses on the laboratory synthesis of pure Kogarkoite to serve as a standard for comprehensive solubility and washing performance testing. A coupled synthesis and simulant campaign was executed using an evaporative crystallization protocol designed to replicate the dynamic concentration effects observed in tank farm operations. Thirteen simulant matrices were prepared by dissolving systematically varied ratios of sodium fluoride (NaF) and sodium sulfate (Na 2 SO 4 ) in deionized water under three distinct caustic regimes: 0.0 g (control), 4.0 g (~1 M), and 12.0 g (~3 M) sodium hydroxide (NaOH). While thermodynamic equilibrium models suggest that high-caustic environments should favor the stability of the double salt7, results from this evaporative study at 25 0 C revealed a distinct kinetic divergence. Simulants with high hydroxide loading predominantly yielded large, blocky crystals of sodium sulfate decahydrate (Na 2 SO 4 .10H 2 O). Successful synthesis of pure Kogarkoite was achieved exclusively in specific NaOH-free compositional windows, where the precipitate manifested as fine, opaque granular aggregates. Ion chromatography (IC) analysis confirmed phase purity through the simultaneous stoichiometric depletion of both fluoride and sulfate from the supernatant. This successful synthesis establishes a reproducible route to generate bulk Kogarkoite, enabling the subsequent phase of quantitative dissolution testing using inhibited water to optimize sludge-batch assembly.

Sarker, Md Sharif [Florida International Univ. (FI↗

Nondestructive experimental determination of bimaterial rectangular cantilever spring constants in water

In order to address the issue of spring constant calibration in viscous fluids such as water, a new method is presented that allows for the experimental calibration of bimaterial cantilever spring constants. This method is based on modeling rectangular cantilever beam bending as a function of changing temperature. The temperature change is accomplished by heating water as it flows around the cantilever beams in an enclosed compartment. The optical static method of detection is used to measure the deflection of cantilever at the free end. Experimentally determined results are compared to Sader's method and to the Thermotune method most commonly used in cantilever calibrations. Results indicate that the new bimaterial thermal expansion method is accurate within 15%-20% of the actual cantilever spring constant, which is comparable to other nondestructive calibration techniques.

42 ENGINEERING↗

Piezoelectric Shaker Development for High Frequency Calibration of Accelerometers

Calibration of vibration transducers requires sinusoidal motion over a wide frequency range with low distortion and low cross-axial motion. Piezoelectric shakers are well suited to generate such motion and are suitable for use with laser interferometric methods at frequencies of 3 kHz and above. An advantage of piezoelectric shakers is the higher achievable accelerations and displacement amplitudes as compared to electro-dynamic (ED) shakers. Typical commercial ED calibration shakers produce maximum accelerations from 100 m/s{sup 2} to 500 m/s{sup 2}. Very large ED shakers may produce somewhat higher accelerations but require large amplifiers and expensive cooling systems to dissipate heat. Due to the limitations in maximum accelerations by ED shakers at frequencies above 5 kHz, the amplitudes of the generated sinusoidal displacement are frequently below the resolution of laser interferometers used in primary calibration methods. This limits the usefulness of ED shakers in interferometric based calibrations at higher frequencies.Small piezoelectric shakers provide much higher acceleration and displacement amplitudes for frequencies above 5 kHz, making these shakers very useful for accelerometer calibrations employing laser interferometric measurements, as will be shown in this paper. These piezoelectric shakers have been developed and used at NIST for many years for high frequency calibration of accelerometers. This paper documents the construction and performance of a new version of these shakers developed at NIST for the calibration of accelerometers over the range of 3 kHz to 30 kHz and possibly higher. Examples of typical calibration results are also given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Throughput Material Characterization using the Virtual Fields Method

Modeling material and component behavior using finite element analysis (FEA) is critical for modern engineering. One key to a credible model is having an accurate material model, with calibrated model parameters, which describes the constitutive relationship between the deformation and the resulting stress in the material. As such, identifying material model parameters is critical to accurate and predictive FEA. Traditional calibration approaches use only global data (e.g. extensometers and resultant force) and simplified geometries to find the parameters. However, the utilization of rapidly maturing full-field characterization techniques (e.g. Digital Image Correlation (DIC)) with inverse techniques (e.g. the Virtual Feilds Method (VFM)) provide a new, novel and improved method for parameter identification. This LDRD tested that idea: in particular, whether more parameters could be identified per test when using full-field data. The research described in this report successfully proves this hypothesis by comparing the VFM results with traditional calibration methods. Important products of the research include: verified VFM codes for identifying model parameters, a new look at parameter covariance in material model parameter estimation, new validation techniques to better utilize full-field measurements, and an exploration of optimized specimen design for improved data richness.

36 MATERIALS SCIENCE↗

Can liquid cloud microphysical processes be used for vertically pointing cloud radar calibration?

Cloud radars are unique instruments for observing cloud processes, but uncertainties in radar calibration have frequently limited data quality. Thus far, no single robust method exists for assessing the calibration of past cloud radar data sets. Here, we investigate whether observations of microphysical processes in liquid clouds such as the transition of cloud droplets to drizzle drops can be used to calibrate cloud radars. Specifically, we study the relationships between the radar reflectivity factor and three variables not affected by absolute radar calibration: the skewness of the radar Doppler spectrum ( γ ), the radar mean Doppler velocity ( W ), and the liquid water path (LWP). For each relation, we evaluate the potential for radar calibration. For γ and W , we use box model simulations to determine typical radar reflectivity values for reference points. We apply the new methods to observations at the Atmospheric Radiation Measurement (ARM) sites North Slope of Alaska (NSA) and Oliktok Point (OLI) in 2016 using two 35 GHz K a -band ARM Zenith Radars (KAZR). For periods with a sufficient number of liquid cloud observations, we find that liquid cloud processes are robust enough for cloud radar calibration, with the LWP-based method performing best. We estimate that, in 2016, the radar reflectivity at NSA was about 1±1  dB too low but stable. For OLI, we identify serious problems with maintaining an accurate calibration including a sudden decrease of 5 to 7 dB in June 2016.

54 ENVIRONMENTAL SCIENCES↗

Predictive Maturity of Multi-Scale Simulation Models for Fuel Performance

The project proposed to provide a Predictive Maturity Framework with its companion metrics that (1) introduce a formalized, quantitative means to communicate information between interested parties, (2) provide scientifically dependable means to claim completion of Validation and Uncertainty Quantification (VU) activities, and (3) guide the decision makers in the allocation of Nuclear Energy’s resources for code development and physical experiments. The project team proposed to develop this framework based on two complimentary criteria: (1) the extent of experimental evidence available for the calibration of simulation models and (2) the sophistication of the physics incorporated in simulation models. The proposed framework is capable of quantifying the interaction between the required number of physical experiments and degree of physics sophistication. The project team has developed this framework and implemented it with a multi-scale model for simulating creep of a core reactor cladding. The multi-scale model is composed of the viscoplastic self-consistent (VPSC) code at the meso-scale, which represents the visco-plastic behavior and changing properties of a highly anisotropic material and a Finite Element (FE) code at the macro-scale to represent the elastic behavior and apply the loading. The framework developed takes advantage of the transparency provided by partitioned analysis, where independent constituent codes are coupled in an iterative manner. This transparency allows model developers to better understand and remedy the source of biases and uncertainties, whether they stem from the constituents or the coupling interface by exploiting separate-effect experiments conducted within the constituent domain and integral-effect experiments conducted within the full-system domain. The project team has implemented this procedure with the multi- scale VPSC-FE model and demonstrated its ability to improve the predictive capability of the model. Within this framework, the project team has focused on optimizing resource allocation for improving numerical models through further code development and experimentation. Related to further code development, we have developed a code prioritization index (CPI) for coupled numerical models. CPI is implemented to effectively improve the predictive capability of the coupled model by increasing the sophistication of constituent codes. In relation to designing new experiments, we investigated the information gained by the addition of each new experiment used for calibration and bias correction of a simulation model. Additionally, the variability of ‘information gain’ through the design domain has been investigated in order to identify the experiment settings where maximum information gain occurs and thus guide the experimenters in the selection of the experiment settings. This idea was extended to evaluate the information gain from each experiment can be improved by intelligently selecting the experiments, leading to the development of the Batch Sequential Design (BSD) technique. Additionally, we evaluated the importance of sufficiently exploring the domain of applicability in experiment-based validation of high-consequence modeling and simulation by developing a new metric to quantify coverage. This metric has also been incorporated into the design of new experiments. Finally, we have proposed a data-aware calibration approach for the calibration of numerical models. This new method considers the complexity of a numerical model (the number of parameters to be calibrated, parameter uncertainty, and form of the model) and seeks to identify the number of experiments necessary to calibrate the model based on the level of sophistication of the physics. The final component in the project team’s work to improve model calibration and validation methods is the incorporation of robustness to non-probabilistic uncertainty in the input parameters. This is an improvement to model validation and uncertainty quantification stemming beyond the originally proposed scope of the project. We have introduced a new metric for incorporating the concept of robustness into experiment-based validation of numerical models. This project has accounted for the graduation of two Ph.D. students (Kendra Van Buren and Josh Hegenderfer) and two M.S. students (Matthew Egeberg and Parker Shields). One of the doctoral students is now working in the nuclear engineering field and the other one is a post-doctoral fellow at the Los Alamos National Laboratory. Additionally, two more Ph.D. students (Garrison Stevens and Tunc Kulaksiz) who are working towards graduation have been supported by this project.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Contributed Review: Absolute spectral radiance calibration of fiber-optic shock-temperature pyrometers using a coiled-coil irradiance standard lamp

We describe an accurate and precise calibration procedure for multichannel optical pyrometers such as the 6-channel, 3-ns temporal resolution instrument used in the Caltech experimental geophysics laboratory. We begin with a review of calibration sources for shock temperatures in the 3000-30 000 K range. High-power, coiled tungsten halogen standards of spectral irradiance appear to be the only practical alternative to NIST-traceable tungsten ribbon lamps, which are no longer available with large enough calibrated area. However, non-uniform radiance complicates the use of such coiled lamps for reliable and reproducible calibration of pyrometers that employ imaging or relay optics. Careful analysis of documented methods of shock pyrometer calibration to coiled irradiance standard lamps shows that only one technique, not directly applicable in our case, is free of major radiometric errors. We provide a detailed description of the modified Caltech pyrometer instrument and a procedure for its absolute spectral radiance calibration, accurate to ±5%. We employ a designated central area of a 0.7× demagnified image of a coiled-coil tungsten halogen lamp filament, cross-calibrated against a NIST-traceable tungsten ribbon lamp. We give the results of the cross-calibration along with descriptions of the optical arrangement, data acquisition, and processing. We describe a procedure to characterize the difference between the static and dynamic response of amplified photodetectors, allowing time-dependent photodiode correction factors for spectral radiance histories from shock experiments. We validate correct operation of the modified Caltech pyrometer with actual shock temperature experiments on single-crystal NaCl and MgO and obtain very good agreement with the literature data for these substances. We conclude with a summary of the most essential requirements for error-free calibration of a fiber-optic shock-temperature pyrometer using a high-power coiled tungsten halogen irradiance standard lamp.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In situ wavelength calibration of the edge CXS spectrometers on JET

A method for obtaining an accurate wavelength calibration over the entire focal plane of the JET edge CXS spectrometers is presented that uses a combination of the fringe pattern created with a Fabry–Pérot etalon and a neon lamp for cross calibration. The accuracy achieved is 0.03 Å, which is the same range of uncertainty as when neglecting population effects on the rest wavelength of the CX line. For the edge CXS diagnostic, this corresponds to a flow velocity of 4.5 km/s in the toroidal direction or 1.9 km/s in the poloidal direction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a new radiometer for the thermodynamic measurement of high temperature fixed points

The National Physical Laboratory (NPL) has developed a new radiometer to measure the thermodynamic melting point temperatures of high temperature fixed points with ultra-low uncertainties. In comparison with the NPL's Absolute Radiation Thermometer (ART), the 'THermodynamic Optical Radiometer' (THOR) is more portable and compact, with a much lower size-of-source effect and improved performance in other parameters such as temperature sensitivity. It has been designed for calibration as a whole instrument via the radiance method, removing the need to calibrate the individual subcomponents, as required by ART, and thereby reducing uncertainties. In addition, the calibration approach has been improved through a new integrating sphere that has been designed to have greater uniformity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗