Search NASA⌕ Search

SEARCH · Search NASA

Results for “Condition Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Analysis of the Trip of a High-Power Turbine-Generator of a Nuclear Power Plant Upon Damage of the Stator Winding Insulation According to Data of Monitoring and Modeling

The operating conditions of a turbine-generator with the stator winding short-circuited to the frame are analyzed. The features of the shape of the zero-sequence voltage during arcing in the damaged gap are described. The operation of the relay protection in these conditions is analyzed. The real oscillograms of the subsequent suppression of the rotor field are theoretically justified. It is shown that improving the thyristor excitation system is necessary and possible.

42 ENGINEERING↗

Development of spiral-groove self-acting face seals

An experimental evaluation and a 100-hour endurance test were performed on a spiral groove geometry, self-acting face seal. The seal was tested and operated successfully at maximum conditions of 243.8 m/s surface speed, 199.9 N/sq cm air pressure, and 645.4K (702 F) air temperature. The maximum speed condition of 243.8 m/s was obtained at a shaft speed of 72,500 rpm. Seal wear, gas leakage, and sealing element temperature were monitored during the test. Condition of the seal at the completion of the test was documented and found acceptable for further use. The spiral groove wear rate measured during the endurance test indicates a minimum potential seal life of over 2700 hours. Seal air leakage measured during the test program is within the range considered acceptable for consideration for use in a small gas turbine engine.

Obrien, M.↗

Design of BLDC Motor Diagnostic Device Based on Surge Test for Phase to Ground Fault

BLDC motor is essential in the industrial world, especially it been used for an electric vehicle. The benefit of using BLDC motor is that it has high rate efficiency and low mechanical losses. However, to know the isolation condition of winding and increase reliability, it needs to be tested. With the implementation of surge test based fault detection device of BLDC motor, the condition of BLDC motor can be monitored and maintained according to analysis of its condition. The surge test method used because it is sensitive in detecting the initial damage in the isolation failure process on stator winding. A surge voltage is generated from the Cockroft-Walton and switching circuit with capacitors. The result is analyzed using Error Area Ratio (EAR). The test result shows that the higher the value of resistance and inductance, the smaller the frequency of the surge wave. When the BLDC motor in a parallel short circuit condition, the threshold value of the EAR test-reff has a minimum value of 5.28%, an average of 13.52%, and a maximum of 28.55%.

BLDC motor↗

Monitoring by Use of Clusters of Sensor-Data Vectors

The inductive monitoring system (IMS) is a system of computer hardware and software for automated monitoring of the performance, operational condition, physical integrity, and other aspects of the health of a complex engineering system (e.g., an industrial process line or a spacecraft). The input to the IMS consists of streams of digitized readings from sensors in the monitored system. The IMS determines the type and amount of any deviation of the monitored system from a nominal or normal ( healthy ) condition on the basis of a comparison between (1) vectors constructed from the incoming sensor data and (2) corresponding vectors in a database of nominal or normal behavior. The term inductive reflects the use of a process reminiscent of traditional mathematical induction to learn about normal operation and build the nominal-condition database. The IMS offers two major advantages over prior computational monitoring systems: The computational burden of the IMS is significantly smaller, and there is no need for abnormal-condition sensor data for training the IMS to recognize abnormal conditions. The figure schematically depicts the relationships among the computational processes effected by the IMS. Training sensor data are gathered during normal operation of the monitored system, detailed computational simulation of operation of the monitored system, or both. The training data are formed into vectors that are used to generate the database. The vectors in the database are clustered into regions that represent normal or nominal operation. Once the database has been generated, the IMS compares the vectors of incoming sensor data with vectors representative of the clusters. The monitored system is deemed to be operating normally or abnormally, depending on whether the vector of incoming sensor data is or is not, respectively, sufficiently close to one of the clusters. For this purpose, a distance between two vectors is calculated by a suitable metric (e.g., Euclidean distance) and "sufficiently close" signifies lying at a distance less than a specified threshold value. It must be emphasized that although the IMS is intended to detect off-nominal or abnormal performance or health, it is not necessarily capable of performing a thorough or detailed diagnosis. Limited diagnostic information may be available under some circumstances. For example, the distance of a vector of incoming sensor data from the nearest cluster could serve as an indication of the severity of a malfunction. The identity of the nearest cluster may be a clue as to the identity of the malfunctioning component or subsystem. It is possible to decrease the IMS computation time by use of a combination of cluster-indexing and -retrieval methods. For example, in one method, the distances between each cluster and two or more reference vectors can be used for the purpose of indexing and retrieval. The clusters are sorted into a list according to these distance values, typically in ascending order of distance. When a set of input data arrives and is to be tested, the data are first arranged as an ordered set (that is, a vector). The distances from the input vector to the reference points are computed. The search of clusters from the list can then be limited to those clusters lying within a certain distance range from the input vector; the computation time is reduced by not searching the clusters at a greater distance.

Iverson, David L.↗

An Advanced Extreme Environment Wireless Telemetry System for Turbine Blade Instrumentation

As advanced natural gas power generation systems evolve, the thrust for increased efficiencies and reduced emissions results in increasingly harsh conditions inside the turbine environment. These high temperatures, pressures, and corrosive atmospheres result in accelerated rates of degradation, leading to failure of turbine materials and components. The University of Arkansas (UA) and Siemens, in collaboration with the DoE's National Energy Technology Laboratory (NETL), are developing a reliable and long-term monitoring capability in the turbine hot gas path in the form of novel ceramic-based thermocouples and integrated wide band gap instrumentation electronics that will contribute to the overall reliability of gas turbines. When equipped with better monitoring and controls, power plants can operate with increased fuel-burning efficiency, improved process dynamics and gas concentrations, and increased overall longevity of the power plant components. This will result in increased turbine availability and a reduction in outages and maintenance costs. One of the key aspects to driving forward turbine monitoring capability is the development of high temperature capable integrated circuit (IC) electronics. Previous papers have described 500 °C + electronics that were developed primarily from a combination of discrete single transistors combined with supporting high temperature passive components. While these circuits have been tested successfully in high temperature spin test environments, the move to an IC approach will greatly increase the performance and reliability of turbine monitoring systems. This program is developing such capability through the implementation of silicon carbide (SiC) based ICs, and this paper details the initial approach and early testing of the developed devices. This research represents an important step towards the realization of a field deployable high reliability turbine condition monitoring system.

47 OTHER INSTRUMENTATION↗

Metrological analysis of a virtual flowmeter-based transducer for cryogenic helium

The metrological performance of a virtual flowmeter-based transducer for monitoring helium under cryogenic conditions is assessed. At this aim, an uncertainty model of the transducer, mainly based on a valve model, exploiting finite-element approach, and a virtual flowmeter model, based on the Sereg-Schlumberger method, are presented. The models are validated experimentally on a case study for helium monitoring in cryogenic systems at the European Organization for Nuclear Research (CERN). The impact of uncertainty sources on the transducer metrological performance is assessed by a sensitivity analysis, based on statistical experiment design and analysis of variance. In this way, the uncertainty sources most influencing metrological performance of the transducer are singled out over the input range as a whole, at varying operating and setting conditions. This analysis turns out to be important for CERN cryogenics operation because the metrological design of the transducer is validated, and its components and working conditions with critical specifications for future improvements are identified.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microminiaturized, biopotential conditioning system (MBCS)

Multichannel, medical monitoring system allows almost complete freedom of movement for subject during monitoring periods. System comprises monitoring unit (biobelt), transmission line, and data acquisition unit. Belt, made of polybenzimidizole fabric, is wrapped around individual's waist and held in place by overlapping sections of Velcro closure material.

Belasco, N.↗

Innovative Strategy For Long Term Monitoring Of Metal And Radionuclide Plumes

Many government and private industry sites that were once contaminated with radioactive and chemical wastes cannot be cleaned up enough to permit unrestricted human access. The sites will require long term management, in some cases indefinitely, leaving site owners with the challenge of protecting human health and environmental quality at these "legacy" sites. Long-term monitoring of groundwater contamination is one of the largest projected costs in the life cycle of environmental management at the Savannah River Site, the larger DOE complex, and many large federal and private sites. There is a need to optimize the performance and manage the cost of long term surveillance and monitoring at their sites. Currently, SRNL is initiating a pilot field test using alternative protocols for long term monitoring of metals and radionuclides. A key component of the approach is that monitoring efforts are focused on measurement of low cost metrics related to hydrologic and chemical conditions that control contaminant migration. The strategy combines careful monitoring of hydrologic boundary conditions with measurement of master variables such as chemical surrogates along with a smaller number of standard well analyses. In plumes contaminated with metals, master variables control the chemistry of the groundwater system, and include redox variables (ORP, DO, chemicals), pH, specific conductivity, biological community (breakdown/decay products), and temperature. Significant changes in these variables will result in conditions whereby the plume may not be stable and therefore can be used to predict possible plume migration. Conversely, concentration measurements for all types of contaminants in groundwater are a lagging indicator plume movement - major changes contaminant concentrations indicate that contamination has migrated. An approach based on measurement of master variables and explicit monitoring of hydrologic boundary conditions combined with traditional metrics should lead to improved monitoring while simultaneously reducing costs. This paradigm is being tested at the SRS F-Area where an innovative passive remedial system is being monitored and evaluated over the long term prior to traditional regulatory closure. Contaminants being addressed at this site are uranium, strontium-90, iodine-129, and tritium. We believe that the proposed strategies will be more effective in early identification of potential risks; these strategies will also be cost effective because controlling variables are relatively simple to measure. These variables also directly reflect the evolution of the plume through time, so that the monitoring strategy can be modified as the plume 'ages'. This transformational long-term monitoring paradigm will generate large cost savings to DOE, other federal agencies and industry and will provide improved performance and leading indicators of environmental management performance.

54 ENVIRONMENTAL SCIENCES↗

Commissioning of the discrete spot scanning proton beam delivery system at University of Texas M.D. Anderson Cancer Center, Proton Therapy Center, Houston

Purpose: To describe a summary of the clinical commissioning of the discrete spot scanning proton beam at the Proton Therapy Center, Houston (PTC-H). Methods: Discrete spot scanning system is composed of a delivery system (Hitachi ProBeat), an electronic medical record (Mosaiq V 1.5), and a treatment planning system (TPS) (Eclipse V 8.1). Discrete proton pencil beams (spots) are used to deposit dose spot by spot and layer by layer for the proton distal ranges spanning from 4.0 to 30.6 g/cm{sup 2} and over a maximum scan area at the isocenter of 30x30 cm{sup 2}. An arbitrarily chosen reference calibration condition has been selected to define the monitor units (MUs). Using radiochromic film and ion chambers, the authors have measured spot positions, the spot sizes in air, depth dose curves, and profiles for proton beams with various energies in water, and studied the linearity of the dose monitors. In addition to dosimetric measurements and TPS modeling, significant efforts were spent in testing information flow and recovery of the delivery system from treatment interruptions. Results: The main dose monitors have been adjusted such that a specific amount of charge is collected in the monitor chamber corresponding to a single MU, following the IAEA TRS 398 protocol under a specific reference condition. The dose monitor calibration method is based on the absolute dose per MU, which is equivalent to the absolute dose per particle, the approach used by other scanning beam institutions. The full width at half maximum for the spot size in air varies from approximately 1.2 cm for 221.8 MeV to 3.4 cm for 72.5 MeV. The measured versus requested 90% depth dose in water agrees to within 1 mm over ranges of 4.0-30.6 cm. The beam delivery interlocks perform as expected, guarantying the safe and accurate delivery of the planned dose. Conclusions: The dosimetric parameters of the discrete spot scanning proton beam have been measured as part of the clinical commissioning program, and the machine is found to function in a safe manner, making it suitable for patient treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ice reconnaissance by satellite

The paper describes the significant milestones in the use of satellites for snow and ice monitoring. The feasibility of such monitoring was demonstrated by the Tiros 2 satellite in 1961. Nimbus 1 showed that breaks in the sea ice can be easily monitored during continuous nighttime conditions; Nimbus 3 showed the practicality of delineating regions of active melting of ice and snow in temperate areas. Landsat data have been found to be particularly useful for monitoring and studying glaciers and their attendant surface features. Ice concentration can be determined with reasonable accuracy from a sequence of electronically scanned microwave radiomenter images made aboard Nimbus 5. In the future we can expect improved sensors and spacecraft systems with longer operating lives.

Gloersen, P.↗

Correlating Time-Resolved Pressure Measurements With Rim Sealing Effectiveness for Real-Time Turbine Health Monitoring

Purge flow is bled from the upstream compressor and supplied to the under-platform region to prevent hot main gas path ingress that damages vulnerable under-platform hardware components. A majority of turbine rim seal research has sought to identify methods of improving sealing technologies and understanding the physical mechanisms that drive ingress. While these studies directly support the design and analysis of advanced rim seal geometries and purge flow systems, the studies are limited in their applicability to real-time monitoring required for condition-based operation and maintenance. As operational hours increase for in-service engines, this lack of rim seal performance feedback results in progressive degradation of sealing effectiveness, thereby leading to reduced hardware life. To address this need for rim seal performance monitoring, this study utilizes measurements from a one-stage turbine research facility operating with true-scale engine hardware at engine-relevant conditions. Time-resolved pressure measurements collected from the rim seal region are regressed with sealing effectiveness through the use of common machine learning techniques to provide real-time feedback of sealing effectiveness. Two modeling approaches are presented that use a single sensor to predict sealing effectiveness accurately over a range of two turbine operating conditions. Here, the results show that an initial purely data-driven model can be further improved using domain knowledge of relevant turbine operations, which yields sealing effectiveness predictions within 3% of measured values.

42 ENGINEERING↗

Correlating Time-Resolved Pressure Measurements With Rim Sealing Effectiveness for Real-Time Turbine Health Monitoring

Purge flow is bled from the upstream compressor and supplied to the under-platform region to prevent hot main gas path ingress that damages vulnerable under-platform hardware components. A majority of turbine rim seal research has sought to identify methods of improving sealing technologies and understanding the physical mechanisms that drive ingress. While these studies directly support the design and analysis of advanced rim seal geometries and purge flow systems, the studies are limited in their applicability to real-time monitoring required for condition-based operation and maintenance. As operational hours increase for in-service engines, this lack of rim seal performance feedback results in progressive degradation of sealing effectiveness, thereby leading to reduced hardware life. To address this need for rim seal performance monitoring, the present study utilizes measurements from a one-stage turbine research facility operating with true-scale engine hardware at engine-relevant conditions. Time-resolved pressure measurements collected from the rim seal region are regressed with sealing effectiveness through the use of common machine learning techniques to provide real-time feedback of sealing effectiveness. Two modelling approaches are presented that use a single sensor to predict sealing effectiveness accurately over a range of two turbine operating conditions. Results show that an initial purely data-driven model can be further improved using domain knowledge of relevant turbine operations, which yields sealing effectiveness predictions within three percent of measured values.

Compressors↗

Continuous whole-system monitoring toward rapid understanding of production HPC applications and systems

A detailed understanding of HPC applications’ resource needs and their complex interactions with each other and HPC platform resources are critical to achieving scalability and performance. Such understanding has been difficult to achieve because typical application profiling tools do not capture the behaviors of codes under the potentially wide spectrum of actual production conditions and because typical monitoring tools do not capture system resource usage information with high enough fidelity to gain sufficient insight into application performance and demands. In this paper we present both system and application profiling results based on data obtained through synchronized system wide monitoring on a production HPC cluster at Sandia National Laboratories (SNL). We demonstrate analytic and visualization techniques that we are using to characterize application and system resource usage under production conditions for better understanding of application resource needs. Furthermore, our goals are to improve application performance (through understanding application-to-resource mapping and system throughput) and to ensure that future system capabilities match their intended workloads.

97 MATHEMATICS AND COMPUTING↗

Compressive strength and hydration processes of concrete with recycled aggregates

This paper deals with the correlation between the time evolution of the degree of hydration and the compressive strength of Recycled Aggregate Concrete (RAC) for different water to cement ratios and initial moisture conditions of the Recycled Concrete Aggregates (RCAs). Particularly, the influence of such moisture conditions is investigated by monitoring the hydration process and determining the compressive strength development of fully dry or fully saturated recycled aggregates in four RAC mixtures. Hydration processes are monitored via temperature measurements in hardening concrete samples and the time evolution of the degree of hydration is determined through a 1D hydration and heat flow model. The effect of the initial moisture condition of RCAs employed in the considered concrete mixtures clearly emerges from this study. In fact, a novel conceptual method is proposed to predict the compressive strength of RAC-systems, from the initial mixture parameters and the hardening conditions. -- Highlights: •The concrete industry is more and more concerned with sustainability issues. •The use of recycled aggregates is a promising solution to enhance sustainability. •Recycled aggregates affect both hydration processes and compressive strength. •A fundamental approach is proposed to unveil the influence of recycled aggregates. •Some experimental comparisons are presented to validate the proposed approach.

42 ENGINEERING↗

Local Radiation Shielding Design Methodology

The NSLS-II accelerators are housed within a radiation enclosure of normal concrete (and in some places high density concrete) that has been designed to reduce the radiation generated from an assumed operational beam loss or bulk shielding current (BCS) from each accelerator. The beam loss model used to estimate the thickness of this bulk shielding, assumed a beam energy at the expected operating energy and a current loss based on reasonable assumptions for the fraction of the expected operating current. The thickness of the shield was determined to be the amount required to reduce the radiation outside the shield to a maximum dose rate of <0.5mrem/hr. for occupied areas for these normal operational losses. These assumed beam losses and the bulk shielding thicknesses required are given in reference [1]. Abnormal operating conditions generating higher than normal beam losses must also be considered, and additional engineering controls will be required depending on the magnitude of the radiation levels generated during the abnormal condition. Additional local shielding subject to configuration control may be utilized to reduce radiation levels associated with these abnormal loss conditions. Interlocked area radiation monitors are another means to prevent continued operation with higher than an acceptable level. The NSLS-II Shielding Policy requires that an engineered system be utilized to mitigate an abnormal condition producing radiation levels greater than 100 mR/h, and that two systems are required if the projected radiation levels during a fault condition are > 2000 mR/h. It is intended that shielding limits the dose rate to < 0.5 mR/h in occupied areas for normal operational losses, and the combination of administrative and engineered controls for abnormal losses will maintain radiation exposure to trained personnel working at the NSLS-II facility to as low as reasonably achievable. It is anticipated that all individual exposures will be well within the planned administrative control level of 100mrem/year. This technical note presents the method used to identify these potential high beam loss locations, evaluate the potential radiation risk these losses create outside the enclosure shield and the design process that specifies the required local radiation shielding needed to reduce this risk below the maximum dose rate of the bulk shield design, listed above. If shielding can’t be adequately provided or if other fault initiated losses could occur, then the necessary engineering controls will be indicated that will limit the energy, current or duration of the beam transport that constitute this high beam loss risk.

36 MATERIALS SCIENCE↗

Local Radiation Shielding Design Methodology

The NSLS-II accelerators are housed within a radiation enclosure of normal concrete (and in some places high density concrete) that has been designed to reduce the radiation generated from an assumed operational beam loss or bulk shielding current (BCS) from each accelerator. The beam loss model used to estimate the thickness of this bulk shielding, assumed a beam energy at the expected operating energy and a current loss based on reasonable assumptions for the fraction of the expected operating current. The thickness of the shield was determined to be the amount required to reduce the radiation outside the shield to a maximum dose rate of <0.5mrem/hr. for occupied areas for these normal operational losses. These assumed beam losses and the bulk shielding thicknesses required are given in reference. Abnormal operating conditions generating higher than normal beam losses must also be considered, and additional engineering controls will be required depending on the magnitude of the radiation levels generated during the abnormal condition. Additional local shielding subject to configuration control may be utilized to reduce radiation levels associated with these abnormal loss conditions. Interlocked area radiation monitors are another means to prevent continued operation with higher than an acceptable level. The NSLS-II Shielding Policy requires that an engineered system be utilized to mitigate an abnormal condition producing radiation levels greater than 100 mR/h, and that two systems are required if the projected radiation levels during a fault condition are > 2000 mR/h. It is intended that shielding limits the dose rate to < 0.5 mR/h in occupied areas for normal operational losses, and the combination of administrative and engineered controls for abnormal losses will maintain radiation exposure to trained personnel working at the NSLS-II facility to as low as reasonably achievable. It is anticipated that all individual exposures will be well within the planned administrative control level of 100mrem/year.

36 MATERIALS SCIENCE↗

Real-Time Diagnosis of Faults Using a Bank of Kalman Filters

A new robust method of automated real-time diagnosis of faults in an aircraft engine or a similar complex system involves the use of a bank of Kalman filters. In order to be highly reliable, a diagnostic system must be designed to account for the numerous failure conditions that an aircraft engine may encounter in operation. The method achieves this objective though the utilization of multiple Kalman filters, each of which is uniquely designed based on a specific failure hypothesis. A fault-detection-and-isolation (FDI) system, developed based on this method, is able to isolate faults in sensors and actuators while detecting component faults (abrupt degradation in engine component performance). By affording a capability for real-time identification of minor faults before they grow into major ones, the method promises to enhance safety and reduce operating costs. The robustness of this method is further enhanced by incorporating information regarding the aging condition of an engine. In general, real-time fault diagnostic methods use the nominal performance of a "healthy" new engine as a reference condition in the diagnostic process. Such an approach does not account for gradual changes in performance associated with aging of an otherwise healthy engine. By incorporating information on gradual, aging-related changes, the new method makes it possible to retain at least some of the sensitivity and accuracy needed to detect incipient faults while preventing false alarms that could result from erroneous interpretation of symptoms of aging as symptoms of failures. The figure schematically depicts an FDI system according to the new method. The FDI system is integrated with an engine, from which it accepts two sets of input signals: sensor readings and actuator commands. Two main parts of the FDI system are a bank of Kalman filters and a subsystem that implements FDI decision rules. Each Kalman filter is designed to detect a specific sensor or actuator fault. When a sensor or actuator fault occurs, large estimation errors are generated by all filters except the one using the correct hypothesis. By monitoring the residual output of each filter, the specific fault that has occurred can be detected and isolated on the basis of the decision rules. A set of parameters that indicate the performance of the engine components is estimated by the "correct" Kalman filter for use in detecting component faults. To reduce the loss of diagnostic accuracy and sensitivity in the face of aging, the FDI system accepts information from a steady-state-condition-monitoring system. This information is used to update the Kalman filters and a data bank of trim values representative of the current aging condition.

Kobayashi, Takahisa↗