Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control Model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

A Discrete-Time Average Model Based Predictive Control for Quasi-Z-Source Inverter

A discrete-time average model-based predictive control (DTA-MPC) is proposed for a quasi-Z-source inverter (qZSI). As a single-stage inverter topology, the qZSI regulates the dc-link voltage and the ac output voltage through the shoot-through (ST) duty cycle and the modulation index. Several feedback strategies have been dedicated to produce these two control variables, among which the most popular are the proportional–integral (PI)-based control and the conventional model-predictive control (MPC). However, in the former, there are tradeoffs between fast response and stability; the latter is robust, but at the cost of high calculation burden and variable switching frequency. Moreover, they require an elaborated design or fine tuning of controller parameters. The proposed DTA-MPC predicts future behaviors of the ST duty cycle and modulation signals, based on the established discrete-time average model of the quasi-Z-source (qZS) inductor current, the qZS capacitor voltage, and load currents. The prediction actions are applied to the qZSI modulator in the next sampling instant, without the need of other controller parameters’ design. A constant switching frequency and significantly reduced computations are achieved with high performance. Transient responses and steady-state accuracy of the qZSI system under the proposed DTA-MPC are investigated and compared with the PI-based control and the conventional MPC. Simulation and experimental results verify the effectiveness of the proposed approach for the qZSI.

42 ENGINEERING↗

The cost of model reference adaptive control - Analysis, experiments, and optimization

In this paper the performance of Model Reference Adaptive Control (MRAC) is studied in numerical simulations and verified experimentally with the objective of understanding how differences between the plant and the reference model affect the control effort. MRAC is applied analytically and experimentally to a single degree of freedom system and analytically to a MIMO system with controlled differences between the model and the plant. It is shown that the control effort is sensitive to differences between the plant and the reference model. The effects of increased damping in the reference model are considered, and it is shown that requiring the controller to provide increased damping actually decreases the required control effort when differences between the plant and reference model exist. This result is useful because one of the first attempts to counteract the increased control effort due to differences between the plant and reference model might be to require less damping, however, this would actually increase the control effort. Optimization of weighting matrices is shown to help reduce the increase in required control effort. However, it was found that eventually the optimization resulted in a design that required an extremely high sampling rate for successful realization.

Messer, R. S.↗

Control of the NASA Langley 16-Foot Transonic Tunnel with the Self-Organizing Map

A predictive, multiple model control strategy is developed based on an ensemble of local linear models of the nonlinear system dynamics for a transonic wind tunnel. The local linear models are estimated directly from the weights of a self-organizing map (SOM). Multiple self-organizing maps collectively model the global response of the wind tunnel to a finite set of representative prototype controls. These prototype controls partition the control space and incorporate experiential knowledge gained from decades of operation. Each SOM models the combination of the tunnel with one of the representative controls, over the entire range of operation. The SOM based linear models are used to predict the tunnel response to a larger family of control sequences which are clustered on the representative prototypes. The control sequence which corresponds to the prediction that best satisfies the requirements on the system output is applied as the external driving signal.

Mark A. Motter↗

Hierarchical Model-Free Transactive Control of Building Loads to Support Grid Services

Residential buildings consume 4.4 quads of electricity annually, approximately 37% of the total electricity consumption in the United States. This represents a vast resource that can be used for demand management and other ancillary services. This project aims to develop a robust, scalable hierarchical transactional control mechanism incorporating elements of model-free control (MFC) and game theory to harness buildings to provide ancillary services to the grid. This approach is being taken to address the challenges of incorporating traditional transactional control schemes into existing buildings. The challenges include small individual building sizes requiring aggregation of many buildings, unpredictable energy usage that makes model identification difficult, and satisfying the sensitive occupant comfort constraints. In the proposed approach, by separating the control mechanism into two layers above and below the load aggregator, MFC can be used below the aggregator to modulate flexible building loads in response to pricing signals with guaranteed performance. This allows the burden of identifying an accurate model of the system to be shifted to the above-aggregator layer, where fluctuations in individual building usage have less impact on predicted building system behavior. Game theory concepts can then be used to determine pricing curves and control signals among regional aggregators. Managing this control in a game-theoretic approach will allow us to build in financial incentives that increase customer engagement. Additionally, the usage of MFC necessitates less burdensome computational and communication requirements, thus, it is easily deployable on small, embedded devices. In a broader sense, developing a strategy capable of effectively incorporating residential and small commercial buildings will allow greater throughput of existing and emerging grid services in addition to future transactive energy grid management methods. Using MFC within a hierarchical control architecture will allow the shifting of existing forecasting challenges to an aggregate level, where dynamics are slower and more predictable. This will enable a smooth interface between the grid services requests of utilities and the reliable control required by participating buildings. MFC, which supports distributed control architecture, permits a scalable solution that can be deployed to neighborhood-size systems as well as individual buildings. This project focuses on three objectives: (1) developing the mathematical framework, algorithm toolkit, and software toolset of the two-layer transactive control testbed; (2) developing a scalable solution for application over many residential and small-size commercial buildings with sparse distributed communication; and (3) field testing and implementation on hardware of the control strategies developed in the previous two objectives. The research and development activities are focused and designed to be impactful within the relevant 2025 targets timeframe. An open-source control framework for exploiting variability and dispatchability of building loads will be delivered as the outcome of the project. This capability enables greater participation of loads in electricity markets and ancillary services that are both useful for the utility and financially beneficial for building owners.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Application of digital computer APU modeling techniques to control system design.

Study of the required controls for a H2-O2 auxiliary power unit (APU) technology program for the Space Shuttle. A steady-state system digital computer program was prepared and used to optimize initial system design. Analytical models of each system component were included. The program was used to solve a nineteen-dimensional problem, and then time-dependent differential equations were added to the computer program to simulate transient APU system and control. Some system parameters were considered quasi-steady-state, and others were treated as differential variables. The dynamic control analysis proceeded from initial ideal control modeling (which considered one control function and assumed the others to be ideal), stepwise through the system (adding control functions), until all of the control functions and their interactions were considered. In this way, the adequacy of the final control design over the required wide range of APU operating conditions was established.

Bailey, D. A.↗

A numerical model including PID control of a multizone crystal growth furnace

This paper presents a 2D axisymmetric combined conduction and radiation model of a multizone crystal growth furnace. The model is based on a programmable multizone furnace (PMZF) designed and built at NASA Lewis Research Center for growing high quality semiconductor crystals. A novel feature of this model is a control algorithm which automatically adjusts the power in any number of independently controlled heaters to establish the desired crystal temperatures in the furnace model. The control algorithm eliminates the need for numerous trial and error runs previously required to obtain the same results. The finite element code, FIDAP, used to develop the furnace model, was modified to directly incorporate the control algorithm. This algorithm, which presently uses PID control, and the associated heat transfer model are briefly discussed. Together, they have been used to predict the heater power distributions for a variety of furnace configurations and desired temperature profiles. Examples are included to demonstrate the effectiveness of the PID controlled model in establishing isothermal, Bridgman, and other complicated temperature profies in the sample. Finally, an example is given to show how the algorithm can be used to change the desired profile with time according to a prescribed temperature-time evolution.

Panzarella, Charles H.↗

In situ synchrotron powder diffraction study of the setting reaction kinetics of magnesium-potassium phosphate cements

This work reports a kinetic study of the formation of magnesium-potassium phosphate cements accomplished using in-situ synchrotron powder diffraction. The reaction: MgO + KH{sub 2}PO{sub 4} + 5H{sub 2}O → MgKPO{sub 4} · 6H{sub 2}O was followed in situ in the attempt of contributing to explain the overall mechanism and assess the influence of periclase (MgO) grain size and calcination temperature (1400-1600 °C) on the reaction kinetics. Numerical kinetic parameters for the setting reaction have been provided for the first time. The best fit to the kinetic data was obtained using a weighted nonlinear model fitting method with two kinetic equations, representing two consecutive, partially overlapping processes. MgO decomposition could be described by a first order (F1) model followed by a Jander diffusion (D3) controlled model. Crystallization of the product of reaction was modelled using an Avrami model (A{sub n}) followed by a first order (F1) chemical reaction. A reaction mechanism accounting for such results has been proposed.

36 MATERIALS SCIENCE↗

Corrective Control to Handle Forecast Uncertainty: A Chance Constrained Optimal Power Flow

Higher shares of electricity generation from renewable energy sources and market liberalization is increasing uncertainty in power systems operation. At the same time, operation is becoming more flexible with improved control systems and new technology such as phase shifting transformers (PSTs) and high voltage direct current connections (HVDC). Previous studies have shown that the use of corrective control in response to outages contributes to a reduction in operating cost, while maintaining N-1 security. In this work, we propose a method to extend the use of corrective control of PSTs and HVDCs to react to uncertainty. We characterize the uncertainty as continuous random variables, and define the corrective control actions through affine control policies. This allows us to efficiently model control reactions to a large number of uncertainty sources. The control policies are then included in a chance constrained optimal power flow formulation, which guarantees that the system constraints are enforced with a desired probability. Lastly, by applying an analytical reformulation of the chance constraints, we obtain a second-order cone problem for which we develop an efficient solution algorithm. In a case study for the IEEE 118 bus system, we show that corrective control for uncertainty leads to a decrease in operational cost, while maintaining system security. Further, we demonstrate the scalability of the method by solving the problem for the IEEE 300 bus and the Polish system test cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quasi-Newton Variational Bayes v.3.0

SAND2024-09052O Quasi-Newton Variational Bayes (QNVB) is a training algorithm that performs high-dimensional variational inference on machine learning models. It provides mechanisms to calibrate and control model uncertainty during training. The PyTorch implementation of projective integral updates for Gaussian mean-fields supports the manuscript, "Projective Integral Updates for High-Dimensional Variational Inference." Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Duersch, Jed↗

A simulation investigation of cockpit display of aircraft traffic during curved, descending, decelerating approaches

The results of a simulation experiment involving the evaluation of cockpit display of aircraft traffic information are presented. The experiment was conducted using taped time dependent, noninteractive traffic in an approach to landing situation and two levels of pilot control models: 3-D automatic and computer augmented control. The tests involved two cases: the simulation aircraft flew approach paths which (1) followed another aircraft in between two other aircraft, and (2) merged between two other aircraft. Speed control via manual throttles was used in all tests (path stretching was not allowed for maintaining separation between aircraft). The approaches were conducted while the simulation aircraft was conducting a curved, descending, decelerating approach to landing. Performance data sets were examined, and subjective opinions regarding workload were gathered. Traffic positioning was varied to further evaluate the test subjects' monitoring performance.

Steinmetz, G. G.↗

Analysis of visual estimation of system state from arbitrary displays

A method is presented for implementing the state estimator of the manual control model when the system output is a visual display of arbitrary form; that is, the display may be pictorial, including real world, or made up of dials and pointers. The method is used to provide error criteria for a look-point controller that appears to be capable of modeling human scanning behavior. This model, if combined with a model of the control process, should be useful in predicting effects of changes in displays on performance of flight tasks.

Gainer, P. A.↗

The MSFC Program Control Development Program

It is the policy of the Marshall Space Flight Center (MSFC) that employees be given the opportunity to develop their individual skills and realize their full potential consistent with their selected career path and with the overall Center's needs and objectives. The MSFC Program Control Development Program has been designed to assist individuals who have selected Program Control or Program Analyst Program Control as a career path to achieve their ultimate career goals. Individuals selected to participate in the MSFC Program Control Development Program will be provided with development training in the various Program Control functional areas identified in the NASA Program Control Model. The purpose of the MSFC Program Control Development Program is to develop individual skills in the various Program Control functions by on-the-job and classroom instructional training on the various systems, tools, techniques, and processes utilized in these areas.

Source record↗

POST2 End-To-End Descent and Landing Simulation for the Autonomous Landing and Hazard Avoidance Technology Project

The Program to Optimize Simulated Trajectories II (POST2) is used as a basis for an end-to-end descent and landing trajectory simulation that is essential in determining the design and performance capability of lunar descent and landing system models and lunar environment models for the Autonomous Landing and Hazard Avoidance Technology (ALHAT) project. This POST2-based ALHAT simulation provides descent and landing simulation capability by integrating lunar environment and lander system models (including terrain, sensor, guidance, navigation, and control models), along with the data necessary to design and operate a landing system for robotic, human, and cargo lunar-landing success. This paper presents the current and planned development and model validation of the POST2-based end-to-end trajectory simulation used for the testing, performance and evaluation of ALHAT project system and models.

Fisher, Jody l.↗

IMPACTS OF SMALL COLUMN ION EXCHANGE STREAMS ON DWPF GLASS FORMULATION: KT05- AND KT06-SERIES GLASS COMPOSITIONS

This report is the second in a series of studies of the impacts of the addition of Crystalline Silicotitanate (CST) and Monosodium Titanate (MST) from the Small Column Ion Exchange (SCIX) process on the Defense Waste Processing Facility (DWPF) glass waste form and the applicability of the DWPF process control models. The KT05-series glasses were selected, fabricated, and characterized to further study glass compositions where iron titanate crystals had been previously found to form. The intent was to better understand the mechanisms and compositions that favored the formation of crystals containing titanium. Formation of these crystalline phases was confirmed. Increased Na{sub 2}O concentrations had little if any impact on reducing the propensity for the formation of the iron titanate crystalline phases. Other physical properties of these glasses were not measured since the intent was to focus on crystallization. Additional studies are suggested to investigate the potential impacts of Al{sub 2}O{sub 3} and K{sub 2}O on crystallization in glasses with high TiO{sub 2} concentrations. The KT06-series glasses were selected, fabricated, and characterized to further study glass compositions that, while broader than the current projections for DWPF feeds with SCIX material, are potential candidates for future processing (i.e., the compositions are acceptable for processing by the Product Composition Control System (PCCS) with the exception of the current TiO{sub 2} concentration constraint). The chemical compositions of these glasses matched well with the target values. The chemical durabilities of all the glasses were acceptable relative to the Environmental Assessment (EA) benchmark. Minor crystallization was identified in some of the slowly cooled glasses, although this crystallization did not impact chemical durability. Several of the KT06-series compositions had durability values that, while acceptable, were not accurately predicted by the current durability models. It was shown that for these high TiO{sub 2} concentration glasses, relatively high Fe{sub 2}O{sub 3} concentrations combined with relatively high Al{sub 2}O{sub 3} concentrations led to durabilities that were unpredictable. Several of the KT06-series glasses also had measured viscosity values that were not well predicted by the current model. A statistical partitioning routine showed that the measured viscosities became unpredictable by the current model when the Fe{sub 2}O{sub 3} concentration in the glasses was less than about 8.2 wt % at the elevated TiO{sub 2} concentrations. The current durability and viscosity models will have to be further evaluated should compositions in these regions become necessary for DWPF processing. Overall, the results presented for the KT06-series glasses show that TiO{sub 2} from the SCIX streams can be incorporated into DWPF-type glasses at concentrations of 6 wt % (in glass) without any detrimental impacts on crystallization or chemical durability that are of practical importance. The measured values for chemical durability and viscosity were acceptable for processing; however, not all of the values were predictable by the current PCCS models. Since the compositions selected for the KT06-series glasses were outside the current projections for DWPF processing with the SCIX streams (in terms of waste components other than TiO{sub 2}), these results help identify compositional regions that, if necessary for processing, would require modifications to the current models. Additional experiments are currently underway. Once completed, all of the measured data will be reviewed and compared to model predictions to better determine whether the validation range of the DWPF process control models can be confidently extended, or whether refitting of the models will be necessary.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The dynamics and control of large flexible space structures. Part A: Discrete model and modal control

Attitude control techniques for the pointing and stabilization of very large, inherently flexible spacecraft systems were investigated. The attitude dynamics and control of a long, homogeneous flexible beam whose center of mass is assumed to follow a circular orbit was analyzed. First order effects of gravity gradient were included. A mathematical model which describes the system rotations and deflections within the orbital plane was developed by treating the beam as a number of discretized mass particles connected by massless, elastic structural elements. The uncontrolled dynamics of the system are simulated and, in addition, the effects of the control devices were considered. The concept of distributed modal control, which provides a means for controlling a system mode independently of all other modes, was examined. The effect of varying the number of modes in the model as well as the number and location of the control devices were also considered.

Bainum, P. M.↗

A Reference Model for Distribution Grid Control in the 21st Century

Intensive changes in the structure of the grid due to the penetration of new technologies, coupled with changing societal needs are outpacing the capabilities of traditional grid control systems. The gap is widening at an accelerating rate with the biggest impacts occurring at the distribution level due to the widespread adoption of diverse distribution-connected energy resources (DER) . This paper outlines the emerging distribution grid control environment, defines the new distribution control problem, and provides a distribution control reference model. The reference model offers a schematic representation of the problem domain to inform development of system architecture and control solutions for the high-DER electric system.

24 POWER TRANSMISSION AND DISTRIBUTION↗