Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detector simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Cycle-by-cycle Delay Estimation at Signalized Intersections by using Machine Learning and Simulated Video Detection Data

Accurate estimation of delay is crucial for efficient traffic signal operations. Estimation of delay in the real-time manner using traditional loop detectors requires advanced detectors (in addition to stop-bar detection). In cases when this detection layout is not in place, delay estimates are approximated with a lower accuracy. Video detection is one of the most frequently deployed detection systems at signalized intersections in recent years. In most cases video detection operates in the same way as traditional inductive loops. However, when coupled with computer vision algorithms, video detection systems could be used to retrieve additional information (e.g., vehicular arrivals and departures) that cannot be taken out from the conventional systems (e.g., long stop-bar loop detectors). Although present for several decades, video detection data were not frequently examined for delay estimation purposes. In this study, we proposed a novel delay estimation model which can be developed with only data from stop-bar video detectors. Relevant data were collected from a simulation model of 11 signalized intersections at downtown Chattanooga, TN and processed to create needed inputs for model development. With the use of multigene genetic programming the authors developed a delay model that outperforms accuracy of multi regression model. Furthermore, authors evaluated the developed model by comparison with the other benchmark delay models, such as HCM and approach delay model. It was found that the developed MGGP delay model outperforms benchmark models for a wide range of traffic and signal operation conditions.

Erdagi, Ismet Goksad↗

Parametric Evaluation of Active Neutron Interrogation for the Detection of Shielded Highly-Enriched Uranium in the Field

Parametric studies using numerical simulations are being performed to assess the performance capabilities and limits of active neutron interrogation for detecting shielded highly enriched uranium (HEU). Varying the shield material, HEU mass, HEU depth inside the shield, and interrogating neutron source energy, the simulations account for both neutron and photon emission signatures from the HEU with resolution in both energy and time. The results are processed to represent different irradiation timing schemes and several different classes of radiation detectors, and evaluated using a statistical approach considering signal intensity over background. This paper describes the details of the modeling campaign and some preliminary results, weighing the strengths of alternative measurement approaches for the different irradiation scenarios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Heavy Gas Cherenkov Detector Construction for Hall C at Thomas Jefferson National Accelerator Facility

The Thomas Jefferson National Accelerator Facility (JLab) has undertaken the 12 GeV Upgrade to double the accelerating energy of its electron beam. This attracts many interesting proposals to probe the quark-gluon nature of nuclear matter at higher energy, therefore a new set of equipment is required. Experimental Hall C of JLab has planned to construct a new Super High Momentum Spectrometer (SHMS) to replace the existing Short Orbit Spectrometer (SOS). The University of Regina is assigned to construct the Heavy Gas Cerenkov (HGC) Detector as part of the SHMS focal plane detectors. This detector will be used as critical component to provide reliable pion/kaon separation between 3-11 GeV/c central momenta in the SHMS experimental program. In this thesis, we will report the design, quality control studies and simulated expected performances of the HGC detector.

Wenliang, Li↗

Monte Carlo semi-empirical model for Si(Li) x-ray detector: Differences between nominal and fitted parameters

A detailed characterization of a X-ray Si(Li) detector was performed to obtain the energy dependence of efficiency in the photon energy range of 6.4 - 59.5 keV, which was measured and reproduced by Monte Carlo (MC) simulations. Significant discrepancies between MC and experimental values were found when the manufacturer parameters of the detector were used in the simulation. A complete Computerized Tomography (CT) detector scan allowed to find the correct crystal dimensions and position inside the capsule. The computed efficiencies with the resulting detector model differed with the measured values no more than 10% in most of the energy range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of a ton-scale water-based liquid scintillator detector

This study reports the performance and light yield of 1% concentration water-based liquid scintillator (WbLS) deployed in a 1000-liter detector. A light yield of 99± 15 photons per MeV is determined by comparing data with simulation. This result aligns with our previous light yield determination using smaller detectors, thus establishing a solid foundation for the ongoing development and deployment of WbLS in larger-scale detectors. In conclusion, the feasibility of in situ preparation and the stability of light yield in WbLS are demonstrated, reinforcing its suitability for long-term experimental endeavors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a segmented n-type germanium detector, and its application to astronomical gamma-ray spectroscopy

Extensive calculations and simulations have shown that the instrumental background in a coaxial germanium photon detector flown at balloon altitudes or in space, can be substantially reduced by segmenting the outer contact. The contact is divided into horizontal strips around the side of the detector, giving it many characteristics similar to that of a stack of planar detectors. By choosing different segment coincidence requirements in different energy ranges, one can obtain a factor of approx. 2 increase in sensitivity to spectral lines between 40 keV and 1 MeV, compared with an unsegmented detector. The reverse electrode configuration (using n-type germanium), with the p contact outside, is preferred for this application due to its thin dead layer and resistance to radiation damage in space. A small two segment n type detector is being developed to serve as a prototype for larger multisegment devices. Results of this development effort and of detector tests are presented.

Gehrels, N.↗

The development of a segmented N-type germanium detector, and its application to astronomical gamma-ray spectroscopy

Extensive calculations and simulations have shown that the instrumental background in a coaxial germanium photon detector flown at balloon altitudes or in space, can be substantially reduced by segmenting the outer contact. The contact is divided into horizontal strips around the side of the detector, giving it many characteristics similar to that of a stack of planar detectors. By choosing different segment coincidence requirements in different energy ranges, one can obtain a factor of approx. 2 increase in sensitivity to spectral lines between 40 keV and 1 MeV, compared with an unsegmented detector. The reverse electrode configuration (using n-type germanium), with the p contact outside, is preferred for this application due to its thin dead layer and resistance to radiation damage in space. A small two segment n type detector is being developed to serve as a prototype for larger multisegment devices. Results of this development effort and of detector tests are presented. Previously announced in STAR as N84-13039

Gehrels, N.↗

Unfolding neutron spectrum with Markov Chain Monte Carlo at MIT research Reactor with He-3 Neutral Current Detectors [Measuring neutron spectrum at MIT research reactor utilizing He-3 Bonner Cylinder Approach with an unfolding analysis]

Here, the Ricochet experiment seeks to measure Coherent (neutral-current) Elastic Neutrino-Nucleus Scattering (CEνNS) using dark-matter-style detectors with sub-keV thresholds placed near a neutrino source, such as the MIT (research) Reactor (MITR), which operates at 5.5 MW generating approximately 2.2 × 10 18 ν/second in its core. Currently, Ricochet is characterizing the backgrounds at MITR, the main component of which comes in the form of neutrons emitted from the core simultaneous with the neutrino signal. To characterize this background, we wrapped Bonner cylinders around a 3 2 He thermal neutron detector, whose data was then unfolded via a Markov Chain Monte Carlo (MCMC) to produce a neutron energy spectrum across several orders of magnitude. We discuss the resulting spectrum and its implications for deploying Ricochet at the MITR site as well as the feasibility of reducing this background level via the addition of polyethylene shielding around the detector setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Test of the Equivalence Principle in an Einstein Elevator

This Annual Report illustrates the work carried out during the last grant-year activity on the Test of the Equivalence Principle in an Einstein Elevator. The activity focused on the following main topics: (1) analysis and conceptual design of a detector configuration suitable for the flight tests; (2) development of techniques for extracting a small signal from data strings with colored and white noise; (3) design of the mechanism that spins and releases the instrument package inside the cryostat; and (4) experimental activity carried out by our non-US partners (a summary is shown in this report). The analysis and conceptual design of the flight-detector (point 1) was focused on studying the response of the differential accelerometer during free fall, in the presence of errors and precession dynamics, for various detector's configurations. The goal was to devise a detector configuration in which an Equivalence Principle violation (EPV) signal at the sensitivity threshold level can be successfully measured and resolved out of a much stronger dynamics-related noise and gravity gradient. A detailed analysis and comprehensive simulation effort led us to a detector's design that can accomplish that goal successfully.

Shapiro, Irwin I.↗

Cosmic-muon characterization and annual modulation measurement with Double Chooz detectors

A study on cosmic muons has been performed for the two identical near and far neutrino detectors of the Double Chooz experiment, placed at ∼120 and ∼300 m.w.e. underground respectively, including the corresponding simulations using the MUSIC simulation package. This characterization has allowed us to measure the muon flux reaching both detectors to be (3.64 ± 0.04) × 10{sup −4} cm{sup −2}s{sup −1} for the near detector and (7.00 ± 0.05) × 10{sup −5} cm{sup −2}s{sup −1} for the far one. The seasonal modulation of the signal has also been studied observing a positive correlation with the atmospheric temperature, leading to an effective temperature coefficient of α {sub T} = 0.212 ± 0.024 and 0.355 ± 0.019 for the near and far detectors respectively. These measurements, in good agreement with expectations based on theoretical models, represent one of the first measurements of this coefficient in shallow depth installations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TU-A-9A-03: Development and Verification of a Forward Model That Assists in Iterative Post-Processing Algorithms Used to Reduce Blur in Compton Backscatter Imaging Systems

Purpose: In Compton Backscatter Imaging (CBI), the source and detector reside on the same side of the patient. We previously demonstrated the applicability of CBI systems for medical purposes using an industrial system. To assist in post-processing images from a CBI system, a forward model based on radiation absorption and scatter principles has been developed. Methods: The forward model was developed in C++ using raytracing to track particles. The algorithm accepts phantoms of any size and resolution to calculate the fraction of incident photons scattered back to the detector, and can perform these calculations for any detector geometry and source specification. To validate the model, results were compared to MCNP-X, which is a Monte Carlo based simulation software, for various combinations of source specifications, detector geometries, and phantom compositions. Results: The model verified that the backscatter signal to the detector was based on three interaction probabilities: a) attenuation of photons going into the phantom, b) Compton scatter of photons toward the detector, and c) attenuation of photons coming out of the phantom. The results from the MCNP-X simulations and the forward model varied from 1 to 5%. This difference was less than 1% for energies higher than 30 keV, but was up to 4% for lower energies. At 50 keV, the difference was less than 1% for multiple detector widths and for both homogeneous and heterogeneous phantoms. Conclusion: As part of the optimization of a medical CBI system, an efficient and accurate forward model was constructed in C++ to estimate the output of CBI system. The model characterized individual components contributing to CBI output and increased computational efficiency over Monte Carlo simulations. It is now used in the development of novel post-processing algorithms that reduce image blur by reversing undesired contribution from outside the region of interest.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-J-51: Dose Response of Common Solid State Detectors in Homogeneous Transverse and Longitudinal Magnetic Fields

Purpose: Solid state radiation detectors are often used for dose profiles and percent depth dose measurements. The dose response of selected solid state detectors is evaluated in varying transverse and longitudinal magnetic fields for eventual use in MR-Linac devices. Methods: A PTW 60003 and IBA PFD detector were modeled in the Monte Carlo code PENELOPE, incorporating a magnetic field which was varied in strength and oriented both transversely and longitudinally with respect to the incident photon beam. The detectors' long axis was in turn oriented either parallel or perpendicular to the photon beam. Dose to the active volume of each detector was scored, and its ratio to dose with zero magnetic field strength (dose response) was determined. Accuracy of the simulations was evaluated by measurements using both chambers taken at low field with a small electromagnet. Simulations were also performed in a water phantom to compare to the in air results. Results: Significant dose response was found in transverse field geometries, nearing 20% at 1.5T. The response is highly dependent on relative orientations to the magnetic field and photon beam, and on detector composition. Low field measurements confirm these results. In the presence of longitudinal magnetic fields, the detectors exhibit little dose response, reaching 0.5–1% at 1.5T regardless of detector orientation. Water tank simulations compared well to the in air simulations when not at the beam periphery, where in transverse magnetic fields only, the water tank simulations differed from the in air results. Conclusion: Transverse magnetic fields can cause large deviations in dose response, and are highly position orientation dependent. Comparatively, longitudinal magnetic fields exhibit little to no dose response in each detector as a function of magnetic field strength. Water tank simulations show longitudinal fields are generally easier to work with, but each detector must be evaluated separately.

07 ISOTOPE AND RADIATION SOURCES↗

Simulation studies related to the particle identification by the forward and backward RICH detectors at Electron Ion Collider

The Electron-Ion collider (EIC) will be the ultimate facility to study the dynamics played by colored quarks and gluons in the phenomenology of nucleons and nuclei, described by Quantum Chromodynamics. The physics programs will greatly rely on efficient particle identification (PID) in both the forward and the backward regions. The forward and the backward RICHes of the EIC have to be able to cover wide acceptance and momentum ranges; in the forward region a dual radiator RICH (dRICH) is foreseen and in the backward region a proximity-focusing RICH can be foreseen to be employed. The geometry and the performance studies of the dRICH have been performed as prescribed in the EIC Yellow Report using the ATHENA software framework. Furthermore, this part of our work reports the effort following the call for EIC detector proposal and the studies related to the forward and the backward RICH performance. In the forward region, the dRICH performance showed a pion- kaon separation from around 1 GeV/c to 50 GeV/c at a three sigma level; the proximity focusing RICH (pfRICH) foreseen for the backward region can reach three sigma separation up to 3 GeV/c for e/$π$ and up to 10 GeV/c for $π$/K mass hypotheses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detector Background at Muon Colliders

Physics goals of a Muon Collider (MC) can only be reached with appropriate design of the ring, interaction region (IR), high-field superconducting magnets, machine-detector interface (MDI) and detector. Results of the most recent realistic simulation studies are presented for a 1.5-TeV MC. It is shown that appropriately designed IR and MDI with sophisticated shielding in the detector have a potential to substantially suppress the background rates in the MC detector. The main characteristics of backgrounds are studied.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comparison of active interrogation methods for source location in a scattering and absorbing medium, consisting of PGNAA, and an AmBe quasi-forward biased directional source

Source location of Special Nuclear Material (SNM) encompassing 95% 235 U and 239 Pu is identified by utilizing a directional source from Patent No: US20190013109A1 using Prompt Gamma Neutron Activation Analysis (PGNAA) and neutron spectroscopy simulated with Monte-Carlo N-Particle transport 6.2 (MCNP). BC-408, HPGe, LaBr 3 detector arrays were used to identify the location of the SNM using total counts incident on each detector, and PGNAA photopeaks from HPGe and LaBr 3 detector arrays in a polyethylene shield. The conducted simulations varied the volume and location of the SNM in the MCNP input files to observe how the source location method behaved. PGNAA photopeaks used for source identification include 61 keV from fission, 2.223 MeV prompt gamma from hydrogen, 511 keV annihilation, and a single and double escape peaks from the prompt gamma interaction from hydrogen. The capabilities of each detector systems to acquire well resolved photopeaks with a 1% relative error or less, and total relative error for F4 and F8 tallies were less than 0.015% relative error. Source predictions of the SNM with uneven amounts of polyethylene shielding between the source and detectors was observed to overpredict and give invalid source location predictions. Source locations of the SNM with even amounts of polyethylene material between the source and each detector were found to be valid. With a 1 Ci 241 Am source activity, it was determined that 1630 s were needed to obtain the results for each detector system with the quasi-forward directional AmBe source. Coupling source and material identification together would increase acquisition time but would only require one system to determine.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Adaptive Thresholding and Parameter Estimation for PPM

A method of adaptive setting of a threshold level for the detection of pulses in a pulse-position modulation (PPM) free-space optical communication system has been developed. In simplified terms, it is desirable to set a threshold value high enough to greatly reduce the probability (PFA as defined below) of erroneously detecting noise as signal pulses but not so high as to greatly reduce the probability (PD as defined below) of detecting any signal pulses that may be present along with noise. In the present method, the threshold level is varied with time, in response to changing conditions in the optical-communication channel, in an effort to maintain a balance between the aforesaid competing requirements. An integral part of this adaptation scheme is a scheme for estimating key parameters of the optical-communication channel in particular, parameters that describe the fading and total attenuation in the channel, and parameters that characterize spreading of pulses by atmospheric and other effects. The method can be implemented by software processing of digitized optoelectronic-detector output, and has been tested by computational simulation. In the first stage of processing by this method, the digitized values of the detector output during noise-only time slots of received PPM symbols are averaged to obtain a background level. This background level is subtracted from the detector output in the hope of reducing or eliminating the noise component in the remaining signal. (This background level should not be confused with the detection threshold, which is computed in the last stage of processing.) Next, the remaining signal - in effect, a vector of pulse samples - is normalized by dividing it by its L1 norm (in general, the L1 norm of a vector is defined as the sum of absolute magnitudes of its orthogonal components).

Arabshahi, Payman↗

TH-EF-207A-05: Feasibility of Applying SMEIR Method On Small Animal 4D Cone Beam CT Imaging

Purpose: Small animal cone beam CT imaging has been widely used in preclinical research. Due to the higher respiratory rate and heat beats of small animals, motion blurring is inevitable and needs to be corrected in the reconstruction. Simultaneous motion estimation and image reconstruction (SMEIR) method, which uses projection images of all phases, proved to be effective in motion model estimation and able to reconstruct motion-compensated images. We demonstrate the application of SMEIR for small animal 4D cone beam CT imaging by computer simulations on a digital rat model. Methods: The small animal CBCT imaging system was simulated with the source-to-detector distance of 300 mm and the source-to-object distance of 200 mm. A sequence of rat phantom were generated with 0.4 mm{sup 3} voxel size. The respiratory cycle was taken as 1.0 second and the motions were simulated with a diaphragm motion of 2.4mm and an anterior-posterior expansion of 1.6 mm. The projection images were calculated using a ray-tracing method, and 4D-CBCT were reconstructed using SMEIR and FDK methods. The SMEIR method iterates over two alternating steps: 1) motion-compensated iterative image reconstruction by using projections from all respiration phases and 2) motion model estimation from projections directly through a 2D-3D deformable registration of the image obtained in the first step to projection images of other phases. Results: The images reconstructed using SMEIR method reproduced the features in the original phantom. Projections from the same phase were also reconstructed using FDK method. Compared with the FDK results, the images from SMEIR method substantially improve the image quality with minimum artifacts. Conclusion: We demonstrate that it is viable to apply SMEIR method to reconstruct small animal 4D-CBCT images.

60 APPLIED LIFE SCIENCES↗