Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dose Characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Beneficial Effect of Li 5 FeO 4 Lithium Source for Li-Ion Batteries with a Layered NMC Cathode and Si Anode

The energy density of lithium-ion batteries can be increased by replacing the traditional graphite anode with a high capacity silicon anode. However, volume changes and interfacial instabilities cause a large irreversible capacity and a continual loss of lithium during cycling, which lead to rapid capacity loss. In this work, we add Li 5 FeO 4 (LFO) to a LiNi 0.5 Mn 0.3 Co 0.2 O 2 (NMC) cathode as a pre-lithiation additive, which increases the lithium inventory and extends the cycle life of Si-graphite/NMC full cells, and decreases the NMC particle degradation. LFO delivers a large 764 mAh g –1 LFO capacity below 4.7 V vs Li/Li + . By tuning the LFO content in Si-graphite/LFO-NMC full cells, we show higher capacity, improved retention, lower impedance, and superior rate performance compared to full cells without LFO. Post-test characterizations demonstrate that LFO inclusion in the cathode matrix leads to less NMC secondary particle segregation/cracking and a thinner surface reduced layer on the NMC particles. The beneficial effects of LFO endure after the lithium reserve has been exhausted, highlighting a lasting synergy between the lithium source and electrode active materials. This study introduces a new approach to simultaneously increase lithium inventory and reduce cathode degradation, and makes critical advances toward enabling Si anodes for lithium-ion batteries.

25 ENERGY STORAGE↗

Comparison of TID Response and SEE Characterization of Single and Multi Level High Density NAND Flash Memories

Heavy ion single-event measurements and TID response for 8Gb commercial NAND flash memories are reported. Radiation results of multi-level flash technology are compared with results from single-level flash technology. In general, these commercial high density memories appear to be much less susceptible to SEE and have better TID response compared to older generations of flash memories. The charge pump survived up to 600 krads.

nonvolatile memory↗

Urinary microRNAs as potential biomarkers of pesticide exposure

MicroRNAs (miRNAs) are post-transcriptional regulators that silence messenger RNAs. Because miRNAs are stable at room temperature and long-lived, they have been proposed as molecular biomarkers to monitor disease and exposure status. While urinary miRNAs have been used clinically as potential diagnostic markers for kidney and bladder cancers and other diseases, their utility in non-clinical settings has yet to be fully developed. Our goal was to investigate the potential for urinary miRNAs to act as biomarkers of pesticide exposure and early biological response by identifying the miRNAs present in urine from 27 parent/child, farmworker/non-farmworker pairs (16FW/11NFW) collected during two agricultural seasons (thinning and post-harvest) and characterizing the between- and within-individual variability of these miRNA epigenetic regulators. MiRNAs were isolated from archived urine samples and identified using PCR arrays. Comparisons were made between age, households, season, and occupation. Of 384 miRNAs investigated, 297 (77%) were detectable in at least one sample. Seven miRNAs were detected in at least 50% of the samples, and one miRNA was present in 96% of the samples. Principal components and hierarchical clustering analyses indicate significant differences in miRNA profiles between farmworker and non-farmworker adults as well as between seasons. Six miRNAs were observed to be positively associated with farmworkers status during the post-harvest season. Expression of five of these miRNA trended towards a positive dose response relationship with organophosphate pesticide metabolites in farmworkers. These results suggest that miRNAs may be novel biomarkers of pesticide exposure and early biological response. - Highlights: • A novel method to identify microRNA biomarkers in urinary samples is proposed. • Six miRNAs have been identified as associated with occupational farm work and pesticide exposure. • An observed seasonal difference suggests transient characteristics of urinary miRNAs.

60 APPLIED LIFE SCIENCES↗

Hepatic cytochrome P450 activity, abundance, and expression throughout human development

Cytochrome P450s are Phase I metabolic enzymes that play critical roles in the biotransformation of endogenous compounds and xenobiotics. The expression and activity of P450 enzymes can vary considerably throughout human development, especially when comparing fetal development to neonates, children, and adults. In an effort to develop a more comprehensive understanding of the ontogeny of P450 expression and activity we employed a multi-omic characterization of P450 transcript expression, protein abundance, and functional activity. To quantify the functional activity of individual P450s we employ activity-based protein profiling, which uses modified mechanism-based inhibitors of P450s as chemical probes, in tandem with proteomic analyses to quantify activity. Our results reveal life-stage-dependent variability in P450 expression, abundance, and activity throughout human development and frequent discordant relationships between expression and activity. The results were used to distribute P450s into three general classes based upon developmental stage of expression and activity. We have significantly expanded the knowledge of P450 ontogeny, particularly at the level of individual P450 activity. We anticipate that our ontogeny results will be useful for enabling predictive therapeutic dosing, and for avoiding potentially adverse and harmful reactions during maturation from both therapeutic drugs and environmental xenobiotics.

Sadler, Natalie C.↗

Deletions at short direct repeats and base substitutions are characteristic mutations for bleomycin-induced double- and single-strand breaks, respectively, in a human shuttle vector system

Using the radiomimetic drug, bleomycin, we have determined the mutagenic potential of DNA strand breaks in the shuttle vector pZ189 in human fibroblasts. The bleomycin treatment conditions used produce strand breaks with 3'-phosphoglycolate termini as > 95% of the detectable dose-dependent lesions. Breaks with this end group represent 50% of the strand break damage produced by ionizing radiation. We report that such strand breaks are mutagenic lesions. The type of mutation produced is largely determined by the type of strand break on the plasmid (i.e. single versus double). Mutagenesis studies with purified DNA forms showed that nicked plasmids (i.e. those containing single-strand breaks) predominantly produce base substitutions, the majority of which are multiples, which presumably originate from error-prone polymerase activity at strand break sites. In contrast, repair of linear plasmids (i.e. those containing double-strand breaks) mainly results in deletions at short direct repeat sequences, indicating the involvement of illegitimate recombination. The data characterize the nature of mutations produced by single- and double-strand breaks in human cells, and suggests that deletions at direct repeats may be a 'signature' mutation for the processing of DNA double-strand breaks.

NASA Discipline Radiation Health↗

Post-irradiation examination to assess performance and safety of nuclear fuel

This work presents some results from testing campaigns performed at JRC-ITU on irradiated fuels and analogues aimed at characterizing fuel alterations during and after irradiation. The characterization of local structural and property changes is the first step towards the description of the overall behaviour of the fuel, including safety- and performance-relevant properties. High burnup light water reactor (LWR) UO{sub 2} fuel (= 60 GWd/tHM) was used for morphology and mechanical property studies. Radial profiles of porosity obtained from scanning electron microscopy image analysis were compared with corresponding sub-surface data obtained using acoustic microscopy. An increase of porosity was observed at the rim of the pellet in correspondence with the high burnup structure (HBS), and also at intermediate radius locations in correspondence with the occurrence of the so-called dark zone. This zone is characterized by several features similar to the HBS: in addition to increased local porosity, grain subdivision features were observed. The examination of grain free surface morphology along the pellet radius revealed the onset of surface alteration which resulted in almost complete loss of the original grain shape in conjunction with the formation of the dark zone. Additionally, possible ageing effects due to accumulation of microstructural decay damage during storage were investigated and compared to the results obtained under accelerated ageing conditions using alpha-doped analogues. Similar hardening trends were observed by comparing the hardness evolution as a function of accumulated damaged in unirradiated analogues and spent fuel. No significant hardness increase was observed on the same high burnup/high dose spent fuel after >10 years of additional storage in hot cell, confirming that hardening saturates at a damage level near 0.1 dpa. These experimental campaigns contribute establishing a basis of data for further analysis, in combination with suitable modelling tools. The final goal is to achieve the full scientific understanding of mechanisms and processes affecting fuel properties and behaviour, as a necessary step to establish the basis for developing advanced fuel systems with optimized performance and safety. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Artificial Soiling Replication of Field Losses on Commercial Photovoltaic Modules

Here, this study demonstrates the capabilities of an indoor artificial soiling approach developed to closely replicate the natural, cyclic soil accumulation processes in the field-dust suspension, deposition, and sedimentation/cementation-for a subtropical climate. In this work, a near-field environment is replicated in an artificial soiling cubic chamber through controlled regulation of humidity, temperature, dust type, and dust concentration, based on site-specific historical climate data. Two different models (MA and MB) of full-size commercial photovoltaic modules from a single manufacturer, installed side by side in the mid-Atlantic United States, were retrieved and subjected to artificial soiling experiments and various characterization measurements, including short-circuit current, colorimetry, reflectance, X-ray fluorescence, laser diffraction, and optical microscopy. Both in the field and in our improved field-representative artificial soiling tests, the MA model experienced roughly twice the soiling loss as the MB model. To closely replicate the field soiling losses for a site-specific climate, it is critical to include: 1) The use of field-collected dust with identical dust chemistry and particle distribution instead of standardized ISO 12103 Arizona Road dusts, 2) the use of only a small amount of field-collected dust inside the chamber during the deposition process (e.g., 0.15 g), and 3) the preconditioning of the surface coating for the partial/full dose of UV stress as experienced in the field during sunlight exposure and the abrasion as experienced in the field during regular module cleaning activities, if/as needed. The field-representative artificial soiling method developed here could potentially be adopted for rank ordering of various antisoiling coatings developed by researchers and industry stakeholders.

14 SOLAR ENERGY↗

WE-DE-207A-01: Parallels in the Evolution of X-Ray Angiographic Systems and Devices Used for Minimally Invasive Endovascular Therapy

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

WE-DE-207A-03: Recent Advances in Devices Used in Neuro--Interventions

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

WE-DE-207A-04: Advances in Radiological Neuro-Endovascular Interventional Imaging

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

Preparation and Characterization of Polyaniline and Ag/ Polyaniline Composite Nanoporous Particles and Their Antimicrobial Activities

Polyaniline (PANI) and Ag/PANI nanoporous composite were prepared by an oxidative polymerization method. The oxidation process of PANI nanoparticles was occurred using (NH{sub 4}){sub 2}S{sub 2}O{sub 8} while the oxidation process of Ag/PANI nanoporous composite was occurred using AgNO{sub 3} under the effect of artificial radiation. The structural, morphological, and optical properties of the PANI and Ag/PANI nanoporous structures were studied using different characterization tools. The results confirm the formation of polycrystalline nanoporous PANI and spherical nanoporous composite of Ag/PANI particles. Antibacterial activity tests against gram-positive bacteria, Bacillus subtilis and Staphylococcus aureus, and gram-negative bacteria, Escherichia coli, and Salmonella species were carried out using different concentrations of PANI nanoparticles and Ag/PANI nanoporous composites. PANI has not antibacterial effect against all studied pathogens. In contrast, Ag/PANI nanoporous composites possessed antibacterial activity that is identified by the zone of inhibition. The inhibition zones of bacteria are in order; Salmonella species > S. aureus > B. subtilis > E. coli. The inhibition zones of all bacteria increased with increasing concentrations of Ag/PANI nanoporous composites from 200 to 400 ppm then decreased with further increasing of the dose concentrations to 600 ppm. Finally, a simplified mechanism based on the electrostatic attraction is presented to describe the antimicrobial activity of Ag/PANI nanoporous composite.

36 MATERIALS SCIENCE↗

Characterization and Modeling of Grain Boundary Chemistry Evolution in Ferritic Steels under Irradiation

Ferritic/martensitic (FM) steels such as HT-9, T-91 and NF12 with chromium concentrations in the range of 9-12 at.% Cr and high Cr ferritic steels (oxide dispersion strengthened steels with 12-18% Cr) are receiving increasing attention for advanced nuclear applications, e.g. cladding and duct materials for sodium fast reactors, pressure vessels in Generation IV reactors and first wall structures in fusion reactors, thanks to their advantages over austenitic alloys. Predicting the behavior of these alloys under radiation is an essential step towards the use of these alloys. Several radiation-induced phenomena need to be taken into account, including phase separation, solute clustering, and radiation-induced segregation or depletion (RIS) to point defect sinks. RIS at grain boundaries has raised significant interest because of its role in irradiation assisted stress corrosion cracking (IASCC) and corrosion of structural materials. Numerous observations of RIS have been reported on austenitic stainless steels where it is generally found that Cr depletes at grain boundaries, consistently with Cr atoms being oversized in the fcc Fe matrix. While FM and ferritic steels are also subject to RIS at grain boundaries, unlike austenitic steels, the behavior of Cr is less clear with significant scatter and no clear dependency on irradiation condition or alloy type. In addition to the lack of conclusive experimental evidence regarding RIS in F-M alloys, there have been relatively few efforts at modeling RIS behavior in these alloys. The need for predictability of materials behavior and mitigation routes for IASCC requires elucidating the origin of the variable Cr behavior. A systematic detailed high-resolution structural and chemical characterization approach was applied to ion-implanted and neutron-irradiated model Fe-Cr alloys containing from 3 to 18 at.% Cr. Atom probe tomography analyses of the microstructures revealed slight Cr clustering and segregation to dislocations and grain boundaries in the ion-irradiated alloys. More significant segregation was observed in the neutron irradiated alloys. For the more concentrated alloys, irradiation did not affect existing Cr segregation to grain boundaries and segregation to dislocation loops was not observed perhaps due to a change in the dislocation loop structure with increasing Cr concentration. Precipitation of α’ was observed in the neutron irradiated alloys containing over 9 at.% Cr. However ion irradiation appears to suppress the precipitation process. Initial low dose ion irradiation experiments strongly suggest a cascade recoil effect. The systematic analysis of grain boundary orientation on Cr segregation was significantly challenged by carbon contamination during ion irradiation or by existing carbon and therefore carbide formation at grain boundaries (sensitization). The combination of the proposed systematic experimental approach with atomistic modeling of diffusion processes directly addresses the programmatic need for developing and benchmarking predictive models for material degradation taking into account atomistic kinetics parameters

36 MATERIALS SCIENCE↗

Fingerprinting Uranium Oxides with Electron Energy Loss Spectroscopy Supported by Theoretical Computations

Uranium oxides occur in a variety of phases that differ in crystal structure and uranium oxidation states. Electron energy loss spectroscopy (EELS) is one of the few techniques that has sufficient spatial resolution and sensitivity to electronic structure to distinguish amongst phases at the nanoscale. However, beam-sensitive materials such as uranium oxides are subject to spectral modification due to interactions with the electron beam. Therefore, theory support is essential to reliably exclude the impact of beam damage and generate true reference datasets. Here we use a comparison of theoretical and experimental spectra to probe the impact of beam damage on O K-edge and U N-edge (N6,7 and N4,5) EELS spectra of various single-valent and mixed-valence uranium oxide bulk phases. Using a low-dose experimental set-up, we show that the O K-edge theoretical spectra are in excellent agreement with experiment for both peak positions and relative intensities of respective peaks. In contrast, U N-edge features are less distinguishing due to the partially localized nature of the U 5f orbitals and overlapping multiplet and spin–orbit coupling effects. This work demonstrates that O K-edge EELS is sufficiently diagnostic to distinguish a wide range of uranium oxides and that the experimental approach used here minimizes beam damage and allows valence state discrimination across the U(IV), U(V) and U(VI) series. When combined with imaging modes available in electron mi-croscopy, the work enables detailed investigation and characterization of uranium redox transformations at the nanoscale.

Carbone, Jacopo↗

Capacitance-Based Dimensional Change Sensors for In-Pile Materials Measurements

Advanced fuel compositions, such as accident tolerate fuels (ATF), are an active area of developing in the nuclear power industry. The long-term performance of these newly developed fuels is estimated through physics-based simulation models of irradiation-, temperature-, pressure-, etc.-induced material degradation. As these fuels are deployed in test reactors, measurement and characterization of the fuel pin evolution is used to validate prediction models. In-pile material evolution parameters, such as fuel rod pressurization, fuel stack and cladding elongation, and cladding diameter, are commonly measured using a linear voltage differential transformer (LVDT). However, LVDTs are bulky and limited to lower (350-500C) temperature operation. The high power density and small size of most experimental positions in high performance research reactors used for accelerated materials irradiation studies generally precludes the use of LVDTs in these reactors. There is a critical need for sensors that provide real-time data regarding material evolution under highly accelerated irradiation. These sensors would ideally have a small profile and the ability to withstand irradiation at extremely high dose rates and temperatures for extended periods of time. A capacitance-based sensor is currently under development at the University of Tennessee to provide a direct measurement of in-pile dimensional change during irradiation. Sensor response was simulated using AutoCAD Electromagnetic field simulator (EMS) for a variety of sensor materials and configurations and fuel pin swelling conditions. Initial results of these simulations are summarized and areas of ongoing research and development are discussed.

Naughton, Tyler↗

Irradiation effects in Generation IV nuclear reactor materials

Generation IV reactor structural materials will be exposed to high doses and temperatures during reactor operation that may lead to irradiation-induced degradation. This degradation will differ from that seen in light water reactors and therefore understanding mechanisms controlling material performance during irradiation is critical for evaluating viability of Generation IV nuclear reactor concepts. This chapter discusses irradiation effects and microstructural changes that affect mechanical properties and dimensional stability of Generation IV reactor materials.

36 MATERIALS SCIENCE↗

Cavity evolution and void swelling in dual ion irradiated tempered martensitic steels

Microstructural evolutions in two variants of the F82H 8 wt%Cr tempered martensitic steel under dual (He + plus Fe 3+ ) ion irradiations at 500 °C have been characterized by transmission electron microscopy. Emphasis is on understanding the combined effects of displacements per atom (dpa) and the helium/dpa ratio (He/dpa) on cavity evolution and void swelling (f v ). The dual ion database includes 231 alloy-dpa-He/dpa conditions for irradiations up to ~ 82 dpa and 3700 appm helium. Here, we hypothesize that the large “scatter” observed in the f v data is primarily due to local microstructural variations, especially those that shield regions at shallower depths from the effects of injected interstitial atoms, which would otherwise reduce f v . More generally, our hypothesis is that the highest f v data, at a specified dpa and He/dpa, provides the most appropriate estimate of swelling for fusion neutron irradiation conditions. The dose dependence of f v can be described by an incubation dpa i , marking the onset of significant void growth, and a post-incubation swelling rate, f v ’ = Δf v /Δdpa. Both dpa i and f v ’ decrease with increasing He/dpa. The f v ’ data are quantitatively consistent with a simple model for defect partitioning between evolving bubble, void, and dislocation sinks strengths and biases. Most notably, the model correctly predicts both the incubation dpa i , and the subsequent f v ’, in spite of the fact that they reflect somewhat different physics. Our analysis also suggests that defect recombination is modest at 500 °C. Along with other considerations, this supports the hypothesis that, even at high dpa rates, dual ion irradiations can be used to reasonably emulate void nucleation and growth for a range of fusion-relevant neutron irradiation service conditions. A companion paper incorporates the results of this study in a reduced-order, data-driven void swelling model.

36 MATERIALS SCIENCE↗

Screening and qualification methodology for SiC end plug processing methods

Deployment of SiC-ceramic-based fuel cladding for light water reactors requires a hermetic end plug–to–cladding joint that can withstand neutron irradiation during normal operation and maintain integrity during design-basis accidents. Reactor experiments have shown that some SiC composite tubes with SiC end plugs can retain hermeticity after irradiation. However, achieving consistent joint performance under irradiation remains a key challenge. Resolving this issue is essential to enable integral irradiation testing and to demonstrate fuel integrity under commercial-reactor irradiation conditions. This report aims to: (1) provide guidance for designing radiation-tolerant end plug joints for SiC cladding; (2) demonstrate experimental methods to detect processing defects that are unstable under neutron irradiation at light-water-reactor-relevant temperatures and doses; and (3) outline a step-by-step approach for designing and conducting reactor experiments to screen joining methods. The resulting data will be used to improve joint processing and to define critical defect types and sizes that must be detected and eliminated through non-destructive evaluation for quality assurance. Based on prior irradiation experiments at the High Flux Isotope Reactor, differential swelling among the cladding, bonding layer, and end plug was identified as an underlying mechanism for irradiation-induced joint degradation. Accordingly, this effect must be considered in the design of radiation-tolerant joining techniques. In this work, miniature SiC end plug joint specimens irradiated during the previous project were analyzed using X-ray computed tomography to characterize the joint microstructure. Digital volume correlation of the tomography data quantified radiation-induced microstructural changes and enabled evaluation of defect-related risks. Finally, ongoing neutron irradiation efforts using larger specimen volumes are presented. These efforts aim to statistically assess joint performance and to build a microstructure–performance (e.g., leak-tightness) dataset to inform processing improvements and quality control.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

In-situ and ex-situ characterization of ion-irradiated AM materials

Additive manufacturing (AM) has attracted increasing attention in recent years as a new way of making high-quality components for nuclear reactors. While AM materials are compositionally similar to their conventionally produced counterparts, they do possess different microstructures, such as dislocation cells and chemical inhomogeneity, that can lead to different mechanical properties and performance behavior. In this study, the irradiation response of AM materials was investigated. In-situ and ex-situ ion irradiations were performed on AM316L and AM316H stainless steels (SS) at 300 and 600°C. The influence of the dislocation cell structure on the evolution of irradiation-induced dislocation loops was evident at 600ºC, but was much weaker at 300ºC. No voids were observed with the in-situ ion irradiation up to 10 dpa at both temperatures. Post-irradiation energy dispersive spectroscopy showed radiation-induced segregation (RIS) near grain boundaries and the formation of Cr-rich oxides throughout the matrix. The extent of segregation at dislocation cell walls varies with dose. Nanoindentation tests performed on the AM316L SS irradiated at 600ºC showed a complex dose dependence with softening at low doses and hardening at high doses.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗