Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

The occurrence and wave properties of H⁺-, He⁺-, and O⁺-band EMIC waves observed by the Van Allen Probes

We perform a statistical study of electromagnetic ion cyclotron (EMIC) waves detected by the Van Allen Probes mission to investigate the spatial distribution of their occurrence, wave power, ellipticity, and normal angle. The Van Allen Probes have been used which allow us to explore the inner magnetosphere (1.1 to 5.8 RE). Magnetic field measurements from the Electric and Magnetic Field Instrument Suite and Integrated Science on board the Van Allen Probes are used to identify EMIC wave events for the first 22 months of the mission operation (8 September 2012 to 30 June 2014). EMIC waves are examined in H⁺-, He⁺-, and O⁺-bands. Over 700 EMIC wave events have been identified over the three different wave bands (265 H⁺-band events, 438 He⁺-band events, and 68 O⁺-band events). EMIC wave events are observed between L = 2 – 8, with over 140 EMIC wave events observed below L = 4. The results show that H⁺-band EMIC waves have two peak magnetic local time (MLT) occurrence regions: pre-noon (09:00 < MLT ≤ 12:00) and afternoon (15:00 < MLT ≤ 17:00) sectors. He⁺-band EMIC waves feature an overall stronger dayside occurrence. O⁺-band EMIC waves have one peak region located in the morning sector at lower L shells (L < 4). He⁺-band EMIC waves average the highest wave power overall (>0.1 nT²/Hz), especially in the afternoon sector. Ellipticity observations reveal that linearly polarized EMIC waves dominate in lower L shells.

58 GEOSCIENCES↗

Very Low Energy Protons From the Beta Decay of Proton Rich Nuclei For Nuclear Astrophysics

We have developed a new experimental technique to measure very low energy protons from beta-delayed p-decay of proton-rich nuclei produced and separated with the MARS recoil spectrometer at TAMU. Recently we have investigated the beta-delayed p-decays of {sup 23}Al and {sup 31}Cl and obtained information on the resonances in the reactions {sup 22}Na(p,gamma){sup 23}Mg and {sup 30}P(p,gamma){sup 31}S, respectively. These reactions are important in explosive H-burning in Novae. A simple setup consisting of a telescope made of a thin double sided Si strip detector (p-detector) backed or sandwiched between two thick Si detectors (beta-detectors) was designed. We studied two different p-detectors and found that the thinner detectors with a small cell size are best to measure proton energies as low as 2-300 keV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Present Status of the NIMS Contract Beamline BL15XU at SPring-8

The revolver undulator beamline BL15XU at SPring-8, which is the contract beamline of National Institute for Materials Science (NIMS), was established for materials science using soft-and-hard X-ray photoelectron spectroscopy (XPS) and high-resolution powder X-ray diffraction (XRD). We have performed beamline reconstruction for further developments of the experiments in the research field of materials science. The flat double-crystal monochromator (DCM) with liquid nitrogen cooling, X-ray total reflection double-mirror system with (+,-) geometry, and high-energy-resolution channel-cut monochromator have been installed into the beamline. The refined beamline provides monochromatic X-rays from 2 to 36 keV. The improvement of the photon flux density at the XRD and XPS experimental stations was confirmed. The photon flux was estimated to be several 10{sup 12} photons/sec with {Delta}E/E of {approx}10{sup -4}.

43 PARTICLE ACCELERATORS↗

The Search for a π 1 (1400) Exotic Meson in the gammap-->Δ ++ ηπ - System with CLAS

Several experiments have reported evidence for the π 1 (1400) using pion production but the results have been controversial and its existence has yet to be seen in photoproduction. Theoretical works have implied that the production amplitude will be greatly increased in photoproduction in comparison to the pion production. The reaction gammap-->Λ ++ X-->pπ + π - (η) is being studied in the photon energy range 4.4 to 5.4 GeV as a possible method of producing the π1(1400) resonance. Data were collected at Jefferson Lab in Hall B. This reaction is being investigated by detecting the pπ + π - 2gamma and reconstructing the eta through the missing-mass of the p π + π - , and comparing the results to the 2γ composite. These data have yielded a 0 (980) and a 2 (1320) in the π - eta invariant mass spectrum. Further analysis is needed to untangle the possible π1(1400) resonance from the a2(1320).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Separation of Copper Isotopes in the Laser Plume

Isotopic separation was observed during ablation of standard copper samples by a nanosecond Nd-YAG laser and a femtosecond Ti:sapphire laser at 266 nm. A time-of-flight mass spectrometer, orthogonal to the direction of the laser plume, was used to measure the isotopic composition of the plasma. A voltage was applied to the pulser at different delay times after the laser was ired in order to obtain a temporal profile as the plume expanded. The fraction of {sup 63}Cu in the plasma detected by the mass spectrometer reaches a maximum of 0.83 at 6 US and 3 {mu}s after the laser is fired for the nanosecond and femtosecond lasers respectively, before falling back to the natural abundance ratio of 0.69. As reported in the literature, the ion peaks are centered at two different delay times, representing fast and slow ion energy distributions. A mechanism based on the electric ield interactions between the electrons and ions is proposed to explain the separation of isotopes in the plume.

07 ISOTOPE AND RADIATION SOURCES↗

Design of RF Feed System for Standing-Wave Accelerator Structures

We are investigating a standing wave structure with an rf feed to each individual cell. This approach minimizes rf power flow and electromagnetic energy absorbed by an rf breakdown. The objective of this work is a robust high-gradient (above 100 MV/m) X-band accelerator structure.

43 PARTICLE ACCELERATORS↗

Measurement of volume resistivity/conductivity of metallic alloy in inhibited seawater by optical interferometry techniques

Optical interferometry techniques were used for the first time to measure the volume resistivity/conductivity of carbon steel samples in seawater with different concentrations of a corrosion inhibitor. In this investigation, the real-time holographic interferometry was carried out to measure the thickness of anodic dissolved layer or the total thickness, U{sub total}, of formed oxide layer of carbon steel samples during the alternating current (ac) impedance of the samples in blank seawater and in 5-20 ppm TROS C-70 inhibited seawater, respectively. In addition, a mathematical model was derived in order to correlate between the ac impedance (resistance) and the surface (orthogonal) displacement of the surface of the samples in solutions. In other words, a proportionality constant [resistivity ({rho}) or conductivity ({sigma})= 1/{rho}] between the determined ac impedance [by electrochemical impedance spectroscopy (EIS) technique] and the orthogonal displacement (by the optical interferometry techniques) was obtained. The value of the resistivity of the carbon steel sample in the blank seawater was found similar to the value of the resistivity of the carbon steel sample air, around 1 x 10{sup -5}{Omega} cm. On the contrary, the measured values of the resistivity of the carbon steel samples were 1.85 x 10{sup 7}, 3.35 x 10{sup 7}, and 1.7 x 10{sup 7}{Omega} cm in 5, 10, and 20 ppm TROS C-70 inhibited seawater solutions, respectively. Furthermore, the determined value range of {rho} of the formed oxide layers, from 1.7 x 10{sup 7} to 3.35 x 10{sup 7}{Omega} cm, is found in a reasonable agreement with the one found in literature for the Fe oxide-hydroxides, i.e., goethite ({alpha}-FeOOH) and for the lepidocrocite ({gamma}-FeOOH), 1 x 10{sup 9}{Omega} cm. The {rho} value of the Fe oxide-hydroxides, 1 x 10{sup 9}{Omega} cm, was found slightly higher than the {rho} value range of the formed oxide layer of the present study. This is because the former value was determined by a dc method rather than by an electromagnetic method, i.e., holographic interferometry with applications of EIS, i.e., ac method. As a result, erroneous measurements were recorded due to the introduction of heat to Fe oxide-hydroxides.

36 MATERIALS SCIENCE↗

Double L{sub 3}M ionization of Pd induced by impact with medium-energy electrons

The electron-induced L{sub 3}M two-step double ionization cross sections of metallic Pd were determined experimentally for incident electron beam energies ranging from the double ionization threshold up to 18 keV. The double L{sub 3}M ionization cross sections were derived from the intensity ratios (I{sub L{alpha}M}:I{sub L{alpha}}) of the resolved M satellites to the parent diagram lines. The sample was bombarded with monoenergetic electrons from an energy-tunable 20-kV electron gun. The diagram and M-satellite x-ray lines were measured by means of high-resolution x-ray spectroscopy, using a reflection-type von Hamos bent crystal spectrometer. The two-step partial cross sections were determined by subtracting from the measured total double ionization cross sections the contributions due to the shake process and L{sub 1}-L{sub 3}M{sub 4,5} Coster-Kronig transitions. Despite the thick target employed in the present study, the dependence of the two-step cross sections on the incoming electron energy could be derived using a target slice decomposition method. It is shown that the obtained energy dependence can be well reproduced by the semiempirical parametrization model of Pattard and Rost.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

{Lambda}-p femtoscopy in collisions of Ar+KCl at 1.76A GeV

Results on {Lambda}p femtoscopy are reported at the lowest energy so far. At a beam energy of 1.76A GeV, the reaction Ar+KCl was studied with the High Acceptance Di-Electron Spectrometer (HADES) at SIS18/GSI. A high-statistics and high-purity {Lambda} sample was collected, allowing for the investigation of {Lambda}p correlations at low relative momenta. The experimental correlation function is compared to corresponding model calculations allowing the determination of the space-time extent of the {Lambda}p emission source. The {Lambda}p source radius is found to be slightly smaller than the pp correlation radius for a similar collision system. The present {Lambda}p radius is significantly smaller than that found for Au+Au/Pb+Pb collisions in the AGS, SPS, and RHIC energy domains but larger than that observed for electroproduction from He. Taking into account all available data, we find the {Lambda}p source radius to increase almost linearly with the number of participants to the power of one-third.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radio emission from extensive air showers as a method for cosmic-ray detection

At the present time, radio emission from extensive air showers (EASs) is being considered as a new promising method for detecting cosmic rays of energy in the region E{sub 0} > 5 x 10{sup 16} eV. Radio emission from an EAS whose development is simulated by the Monte Carlo method is calculated here. The field of radio emission from an EAS is calculated on the basis of two representations of a shower: that as a set of individual particles and that as a continuous set of currents. The sensitivity of radio emission to EAS parameters in the frequency range 10-100 MHz is investigated. The results can be used to analyze experiments that being presently performed (CODALEMA and LOPES) and those that are being planned for the future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Utilizing 3D Mechanical Earth Models for Calibration and Validation in a Large-Scale Carbon Capture and Storage Project in North Dakota

Conference paper presented at 17th International Conference on Greenhouse Gas Control Technologies (GHGT-17), Calgary, Alberta, Canada, October 20–24, 2024. Three-dimensional (3D) mechanical earth models (MEMs) are pivotal in assessing geological sites for carbon dioxide (CO 2 ) storage and mitigating potential risks associated with storage and injection. The Energy & Environmental Research Center is exploring innovative carbon storage monitoring techniques at a CO 2 storage site near Beulah, North Dakota. These methods aim to provide lower-impact, faster feedback for commercial carbon capture and storage (CCS) projects. The research includes monitoring CO 2 injection using various approaches: 1) an automated, integrated modular monitoring station; 2) time-lapse electromagnetic (EM) field surveys; 3) drone-based surveillance; 4) time-lapse seismic techniques; and 5) advanced wellbore monitoring.

02 PETROLEUM↗

A new active base of photomultiplier R4125 designed for the PbWO4 calorimeter

This paper presents the design, performance, and results of the radiation tests of an active base for Hamamatsu R4125 photomultiplier tube. The active base was designed at Jefferson Lab and comprises of a high voltage divider and an on-board amplifier. The photomultiplier with the active base is used to detect light from lead tungstate scintillating crystals of the forward electromagnetic calorimeter of the GlueX detector. The active base amplifier allows to operate the tube at lower high voltage and thus to limit the photomultiplier anode current to a few micro ampereres at the maximum counter rate of 1 MHz counter, while retaining the dynamic range of output signals. The performance of calorimeter modules instrumented with the active base was studied using detector prototypes positioned into the beam of photons. The key performance parameters such as the linearity, high-rate capability, and the energy resolution verified that the active base design meets the detector specifications

Somov, Alexander [Thomas Jefferson National Accele↗

Passive wireless pressure sensor for harsh environments

Methods and apparatuses for measuring static and dynamic pressures in harsh environments are disclosed. A pressure sensor according to one embodiment of the present invention may include a diaphragm constructed from materials designed to operate in harsh environments. A waveguide may be operably connected to the diaphragm, and an electromagnetic wave producing and receiving (e.g., sensing) device may be attached to the waveguide, opposite the diaphragm. A handle may be connected between the diaphragm and the waveguide to provide both structural support and electrical functionality for the sensor. A gap may be included between the handle and the diaphragm, allowing the diaphragm to move freely. An antenna and a ground plane may be formed on the diaphragm or the handle. Electromagnetic waves may be reflected off the antenna and detected to directly measure static and dynamic pressures applied to the diaphragm.

42 ENGINEERING↗

On coincident loop transient electromagnetic induction logging

Coincident loop transient induction wireline logging is examined as the borehole analog of the well-known land and airborne time-domain electromagnetic (EM) method. The concept of whole-space late-time apparent resistivity is modified from the half-space version commonly used in land and airborne geophysics and applied to the coincident loop voltages produced from various formation, borehole, and invasion models. Given typical tool diameters, off-time measurements with such an instrument must be made on the order of nanoseconds to microseconds — much more rapidly than for surface methods. Departure curves of the apparent resistivity for thin beds, calculated using an algorithm developed to model the transient response of a loop in a multilayered earth, indicate that the depth of investigation scales with the bed thickness. Modeled resistivity logs are comparable in accuracy and resolution with standard frequency-domain focused induction logs. However, if measurement times are longer than a few microseconds, the thicknesses of conductors can be overestimated, whereas resistors are underestimated. Thin-bed resolution characteristics are explained by visualizing snapshots of the EM fields in the formation, where a conductor traps the electric field while two current maxima are produced in the shoulder beds surrounding a resistor. Radial profiling is studied using a concentric cylinder earth model. Results found that true formation resistivity can be determined in the presence of either oil- or water-based mud, although in the latter case, measurements must be taken several orders of magnitude later in time. Lastly, the ability to determine true formation resistivity is governed by the degree that the EM field heals after being distorted by borehole fluid and invasion, a process visualized and particularly evident in the case of conductive water-based mud.

58 GEOSCIENCES↗

Planck 2013 results. IX. HFI spectral response

The Planck High Frequency Instrument (HFI) spectral response was determined through a series of ground based tests conducted with the HFI focal plane in a cryogenic environment prior to launch. The main goal of the spectral transmission tests was to measure the relative spectral response (includingthe level of out-of-band signal rejection) of all HFI detectors to a known source of electromagnetic radiation individually. This was determined by measuring the interferometric output of a continuously scanned Fourier transform spectrometer with all HFI detectors. As there is no on-board spectrometer within HFI, the ground-based spectral response experiments provide the definitive data set for the relative spectral calibration of the HFI. Knowledge of the relative variations in the spectral response between HFI detectors allows for a more thorough analysis of the HFI data. The spectral response of the HFI is used in Planck data analysis and component separation, this includes extraction of CO emission observed within Planck bands, dust emission, Sunyaev-Zeldovich sources, and intensity to polarization leakage. The HFI spectral response data have also been used to provide unit conversion and colour correction analysis tools. While previous papers describe the pre-flight experiments conducted on the Planck HFI, this paper focusses on the analysis of the pre-flight spectral response measurements and the derivation of data products, e.g. band-average spectra, unit conversion coefficients, and colour correction coefficients, all with related uncertainties. Verifications of the HFI spectral response data are provided through comparisons with photometric HFI flight data. This validation includes use of HFI zodiacal emission observations to demonstrate out-of-band spectral signal rejection better than 10 8 . The accuracy of the HFI relative spectral response data is verified through comparison with complementary flight-data based unit conversion coefficients and colour correction coefficients. Furthermore, these coefficients include those based upon HFI observations of CO, dust, and Sunyaev-Zeldovich emission. General agreement is observed between the ground-based spectral characterization of HFI and corresponding in-flight observations, within the quoted uncertainty of each; explanations are provided for any discrepancies.

79 ASTRONOMY AND ASTROPHYSICS↗

Blandford's argument: The strongest continuous gravitational wave signal

For a uniform population of neutron stars whose spin-down is dominated by the emission of gravitational radiation, an old argument of Blandford states that the expected gravitational-wave amplitude of the nearest source is independent of the deformation and rotation frequency of the objects. Recent work has improved and extended this argument to set upper limits on the expected amplitude from neutron stars that also emit electromagnetic radiation. We restate these arguments in a more general framework, and simulate the evolution of such a population of stars in the gravitational potential of our galaxy. The simulations allow us to test the assumptions of Blandford's argument on a realistic model of our galaxy. We show that the two key assumptions of the argument (two dimensionality of the spatial distribution and a steady-state frequency distribution) are in general not fulfilled. The effective scaling dimension D of the spatial distribution of neutron stars is significantly larger than two, and for frequencies detectable by terrestrial instruments the frequency distribution is not in a steady state unless the ellipticity is unrealistically large. Thus, in the cases of most interest, the maximum expected gravitational-wave amplitude does have a strong dependence on the deformation and rotation frequency of the population. The results strengthen the previous upper limits on the expected gravitational-wave amplitude from neutron stars by a factor of 6 for realistic values of ellipticity.

79 ASTRONOMY AND ASTROPHYSICS↗