Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy Storage System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Flywheel Rotor Safe-Life Technology

Since the 1960s, research has been conducted into the use of flywheels as energy storage systems. The-proposed applications include energy storage for hybrid and electric automobiles, attitude control and energy storage for satellites, and uninterruptible power supplies for hospitals and computer centers. For many years, however, the use of flywheels for space applications was restricted by the total weight of a system employing a metal rotor. With recent technological advances in the manufacturing of composite materials, however, lightweight composite rotors have begun to be proposed for such applications. Flywheels with composite rotors provide much higher power and energy storage capabilities than conventional chemical batteries. However, the failure of a high speed flywheel rotor could be a catastrophic event. For this reason, flywheel rotors are classified by the NASA Fracture Control Requirements Standard as fracture critical parts. Currently, there is no industry standard to certify a composite rotor for safe and reliable operation forth( required lifetime of the flywheel. Technical problems hindering the development of this standard include composite manufacturing inconsistencies, insufficient nondestructive evaluation (NDE) techniques for detecting defects and/or impact damage, lack of standard material test methods for characterizing composite rotor design allowables, and no unified proof (over-spin) test for flight rotors. As part of a flywheel rotor safe-life certification pro-ram funded b the government, a review of the state of the art in composite rotors is in progress. The goal of the review is to provide a clear picture of composite flywheel rotor technologies. The literature review has concentrated on the following topics concerning composites and composite rotors: durability (fatigue) and damage tolerance (safe-life) analysis/test methods, in-service NDE and health monitoring techniques, spin test methods/ procedures, and containment options. This report presents the papers selected for their relevance to this topic and summarizes them.

Ratner, J. K. H.↗

Energy Northwest - Horn Rapids Solar and Storage: An Assessment of Battery Technical Performance

Chartered in 1957 as a joint action agency of the state, Energy Northwest (ENW) is a consortium of 27 public utility districts and municipalities across Washington state. ENW takes advantage of economies of scale and shared services to help utilities run their operations more efficiently and at lower cost, to the benefit of more than 1.5 million customers. ENW develops, owns, and operates a diverse mix of electricity generating resources, including hydro, solar, and wind projects – and the Northwest’s only active nuclear energy facility. These projects provide enough reliable, affordable, and environmentally responsible energy to power more than a million homes each year, and that carbon-free electricity is provided at the cost of generation. The agency continually explores new generation projects to meet its members’ needs. In 2017, as part of the second round of funding from the Washington state Clean Energy Fund, the Washington State Department of Commerce granted up to $3 million in matching funds to develop an estimated $6.5 million project that deployed a 4-MW, 20-acre solar generating array of photovoltaic (PV) panels coupled with a 1 MW/5.5 MWh lithium-iron-phosphate battery energy storage system (BESS) in Richland, Washington. The combination of PV and BESS will provide a predictable, renewable generating source and will also serve as a training ground for solar and battery technicians throughout the nation. The City of Richland will purchase the power from the project and utilize the benefits of the energy storage. The project provides Washington state with its first opportunity to integrate a large-scale solar and storage facility into its clean mix of hydro, nuclear, and wind resources. This first-of-its-kind facility combines solar generation with battery storage and technician training. In 2019, Pacific Northwest National Laboratory (PNNL) worked with ENW to assess the integrated PV and BESS in representative use cases that could benefit the City of Richland. Between March and May 2022, extensive testing was conducted, and the results were used to assess the technical performance of the BESS subjected to actual field operations. Both reference performance and use case tests were performed: (A) Reference performance tests assess the general technical capabilities of the BESS, such as energy capacity, round-trip efficiency (RTE), ramp rate, and signal tracking capability. These are the first tests performed (baseline), and they are repeated after use case tests (post cycle). A standardized U.S. Department of Energy (DOE) energy storage performance protocol was used to characterize the BESS, including representative duty cycle profiles, test procedure guidance, and calculation guidance for determining key characteristics. (B) Use case tests examine the performance of the BESS for specific use cases using duty cycles developed by PNNL in collaboration with ENW. Five use cases were selected for testing: 1) demand charge reduction, 2) load shaping, 3) transmission charge reduction, 4) Volt-VAR service, and 5) outage mitigation. The use case duty cycles were developed based on utility and site-specific characteristics in addition to the technical characteristics and physical capabilities of the BESS. Use case tests were performed between the baseline and post cycle tests. This report describes the BESS and its components, presents testing and performance analysis results, and shares key insights and lessons learned from this project. Outcomes of the tests and analyses will help ENW understand the performance of the Horn Rapids BESS in its current state and design appropriate operational strategies for this and other BESSs over the long term.

14 SOLAR ENERGY↗

Integration of Superconducting Magnetic Energy Storage (SMES) Systems Optimized with Second-Generation, High-Temperature Superconducting (2G-HTS) Technology with a Major Fossil-Fueled Asset

Utility companies and fossil fueled generation assets are seeking combinations of “hybrid energy storage” to allow power to be provided in advance of, and to otherwise complement, peaking natural gas-fired generation. American Maglev Technology of Florida Inc. (AMT) learned during the Phase I program based on interactions with NRG Energy (NRG) that energy storage such as superconducting magnetic energy storage (SMES) can qualify as a Black Start unit in most markets, ensuring orderly re-start of grid operations and fossil fueled power plants and serving as an important asset of hybrid energy storage technology. In conjunction with the University of Houston (UH), AMT and NRG are working together to scale up low-cost, high- efficiency, second-generation high-temperature superconducting (2G-HTS) technology for deployment across several markets, with a primary focus on the commercial development of utility grid-scale SMES (g-SMES) systems. Ultimately the program confirmed that the novel g-SMES design can meet the performance and financial requirements of the fossil power plant industry, while exhibiting continuous grid-voltage regulation; cost-effective, peak-hour energy storage with almost infinite life; increased input/output efficiency; and the capability to undergo millions of charging cycles, without degradation, representing a significant improvement over lithium ion and other conventional storage technologies. We believe wide scale deployment of this technology is feasible and practical when compared to the higher life cycle cost and relatively short lifespan of chemical batteries. Based on these findings, the future for deployment of SMES at many fossil-fueled power plants exceeding 100MW capability is bright. Further de-risking g-SMES technology would pave the way for the construction of a subscale prototype. Eventually, scaled-down versions of SMES are expected to be competitive with the multi-billion-dollar lithium-ion market for a wide range of commercial, industrial, and transportation uses. There is long-term potential for commercialization and widespread deployment of this disruptive technology, which would spawn a new worldwide supply chain and create domestic, high-tech manufacturing jobs in the green industry.

20 FOSSIL-FUELED POWER PLANTS↗

An Evaluation of Energy Storage Options for Nuclear Power

The dynamics of energy generation, delivery, and consumption in the United States continue to change as new energy sources come online and consumers purchase more energy-intensive devices. The percentage of electricity generation from variable renewable energy sources like wind and solar power has grown year after year. Meanwhile, the evolution of electric vehicles, smart devices, and consumer appliances is changing the way that electricity is used. As a result of these trends, nuclear power plants (NPPs) are being asked to operate more flexibly. Newly constructed, advanced nuclear power plants (A-NPPs) will likely need to adapt their business models with these market shifts in mind. In the future, A-NPPs might operate in an electricity system that values flexibility (e.g. fast ramping) more than stability (e.g. baseload supply). The current fleet of NPPs is struggling to remain economically viable in competitive markets that favor low natural gas prices and renewable energy sources with low marginal costs. Rising construction costs and ambiguous national policies have only added to the challenges facing plant operators. The industry as a whole is in decline, with 19 reactors in the process of being decommissioned and 5 of these plants retiring in the past decade. However, NPPs also provide several performance and environmental benefits by maintaining a high capacity factor and generating almost zero greenhouse gas (GHG) emissions over the life cycle of the plant. As more areas of energy consumption in the United States are electrified, NPPs could potentially replace coal and natural gas as a source of heat and power to help decarbonize the U.S. energy mix. Improving the flexibility of newly constructed A-NPPs to increase revenue through market hedging and reduce costs via stable operation was explored in this analysis. The increasing penetration of variable energy resources could contribute to the uncertainty of electricity demand, which could in turn increase the need for dispatchable electricity generating units. This role is currently filled by inexpensive natural gas combined cycle (NGCC) plants, whereas coal and NPPs have traditionally been called upon to provide baseload power by maintaining a constant power output. As wholesale electricity prices continue to fall due to low natural gas prices and federally subsidized renewable energy, this business model has begun to fail, resulting in incidences of NPPs selling electricity at a loss. Since it has not been economically favorable for NPPs to operate flexibly in this situation in the past, due to their low variable costs compared to fossil fuel power plants, NPPs in the United States were not built with this purpose in mind. Therefore, legacy NPPs have had difficulty adapting to these shifting dynamics due to regulatory and technical constraints, coupled with a lack of meaningful experience. NPPs in France have operated in this manner for years, due to a much higher percentage of baseload generators and a lower percentage of fast-ramping NGCC plants. The integration of energy storage technologies (ESTs) alongside newly constructed A-NPPs will be investigated in this analysis as an alternative method for helping NPPs resolve the economic challenges they currently face. Although the deregulation of energy markets in the United States is responsible for much of the increased competition from natural gas and renewable energy that has negatively impacted NPPs, this process has also led to the creation of ancillary service markets. ESTs can provide many of these services, so an integrated energy storage system could supplement both the reliability of the electricity grid and the economic performance of a NPP by bidding into these markets. However, many technical, financial, and regulatory barriers still prevent ESTs from operating profitably in this space. The purpose of this body of work is to compile a transparent database of metrics for available ESTs and identify barriers to widespread deployment. An analytical selection methodology was also developed to identify favorable technologies for integration with specific NPPs based on information supplied by an interested developer. These tools could help reduce the perceived risk surrounding investment in energy storage systems, which could help both NPPs in need of economic assistance and ESTs in need of further research and development.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Lunar RFC Reliability Testing for Assured Mission Success

NASA's Constellation program has selected the closed cycle hydrogen oxygen Polymer Electrolyte Membrane (PEM) regenerative Fuel Cell (RFC) as its baseline solar energy storage system for the lunar outpost and manned rover vehicles. Since the outpost and manned rovers are "human-rated", these energy storage systems will have to be of proven reliability exceeding 99 percent over the length of the mission. Because of the low (TRL=5) development state of the closed cycle hydrogen oxygen PEM RFC at present, and because there is no equivalent technology base in the commercial sector from which to draw or infer reliability information from, NASA will have to spend significant resources developing this technology from TRL 5 to TRL 9, and will have to embark upon an ambitious reliability development program to make this technology ready for a manned mission. Because NASA would be the first user of this new technology, NASA will likely have to bear all the costs associated with its development. When well-known reliability estimation techniques are applied to the hydrogen oxygen RFC to determine the amount of testing that will be required to assure RFC unit reliability over life of the mission, the analysis indicates the reliability testing phase by itself will take at least 2 yr, and could take up to 6 yr depending on the number of QA units that are built and tested and the individual unit reliability that is desired. The cost and schedule impacts of reliability development need to be considered in NASA's Exploration Technology Development Program (ETDP) plans, since life cycle testing to build meaningful reliability data is the only way to assure "return to the moon, this time to stay, then on to Mars" mission success.

Bents, David J.↗

Lunar Regenerative Fuel Cell (RFC) Reliability Testing for Assured Mission Success

NASA's Constellation program has selected the closed cycle hydrogen oxygen Polymer Electrolyte Membrane (PEM) Regenerative Fuel Cell (RFC) as its baseline solar energy storage system for the lunar outpost and manned rover vehicles. Since the outpost and manned rovers are "human-rated," these energy storage systems will have to be of proven reliability exceeding 99 percent over the length of the mission. Because of the low (TRL=5) development state of the closed cycle hydrogen oxygen PEM RFC at present, and because there is no equivalent technology base in the commercial sector from which to draw or infer reliability information from, NASA will have to spend significant resources developing this technology from TRL 5 to TRL 9, and will have to embark upon an ambitious reliability development program to make this technology ready for a manned mission. Because NASA would be the first user of this new technology, NASA will likely have to bear all the costs associated with its development.When well-known reliability estimation techniques are applied to the hydrogen oxygen RFC to determine the amount of testing that will be required to assure RFC unit reliability over life of the mission, the analysis indicates the reliability testing phase by itself will take at least 2 yr, and could take up to 6 yr depending on the number of QA units that are built and tested and the individual unit reliability that is desired. The cost and schedule impacts of reliability development need to be considered in NASA's Exploration Technology Development Program (ETDP) plans, since life cycle testing to build meaningful reliability data is the only way to assure "return to the moon, this time to stay, then on to Mars" mission success.

Bents, David J.↗

University of South Florida- Phase Change Materials (PCM)

USF is developing low-cost, high-temperature phase-change materials (PCMs) for use in thermal energy storage systems. Heat storage materials are critical to the energy storage process. In solar thermal storage systems, heat can be stored in these materials during the day and released at night--when the sun is not out--to drive a turbine and produce electricity. In nuclear storage systems, heat can be stored in these materials at night and released to produce electricity during daytime peak-demand hours. Most PCMs do not conduct heat very well. Using an innovative, electroless encapsulation technique, USF is enhancing the heat transfer capability of its PCMs. The inner walls of the capsules will be lined with a corrosion-resistant, high-infrared emissivity coating, and the absorptivity of the PCM will be controlled with the addition of nano-sized particles. USF's PCMs remain stable at temperatures from 600 to 1,000°C and can be used for solar thermal power storage, nuclear thermal power storage, and other applications.

25 ENERGY STORAGE↗

Assessment of flywheel energy storage for spacecraft power systems

The feasibility of inertial energy storage in a spacecraft power system is evaluated on the basis of a conceptual integrated design that encompasses a composite rotor, magnetic suspension, and a permanent magnet (PM) motor/generator for a 3-kW orbital average payload at a bus distribution voltage of 250 volts dc. The conceptual design, which evolved at the Goddard Space Flight Center (GSFC), is referred to as a Mechanical Capacitor. The baseline power system configuration selected is a series system employing peak-power-tracking for a Low Earth-Orbiting application. Power processing, required in the motor/generator, provides a potential alternative configurations that can only be achieved in systems with electrochemical energy storage by the addition of power processing components. One such alternative configuration provides for peak-power-tracking of the solar array and still maintains a regulated bus, without the expense of additional power processing components. Precise speed control of the two counterrotating wheels is required to reduce interaction with the attitude control system (ACS) or alternatively, used to perform attitude control functions. Critical technologies identified are those pertaining to the energy storage element and are prioritized as composite wheel development, magnetic suspension, motor/generator, containment, and momentum control. Comparison with a 3-kW, 250-Vdc power system using either NiCd or NiH2 for energy storage results in a system in which inertial energy storage offers potential advantages in lifetime, operating temperature, voltage regulation, energy density, charge control, and overall system weight reduction.

Rodriguez, G. E.↗

Advanced battery modeling for interfacial phenomena and optimal charging

Lithium ion batteries are one of the most promising energy storage systems for portable devices, transportation, and renewable grids. To meet the increasing requirements of these applications, higher energy density and areal capacity, long cycle life, fast charging rate and enhanced safety for lithium ion battery (LIBs) are urgently needed. To solve these challenges, the relevant physics at different length scale need to be understood. However, experimental study is time consuming and limited in small scale’s study. Modeling techniques provide us powerful tools to get a deep understanding of the relevant physics and find optimal solutions. This work focuses on studying the mechanism in advanced battery engineering techniques and developing a new charging algorithm by model-based optimization. The research topics are divided into six topics and each topic is reported as a form of journal publication. Paper Ⅰ provides a new aspect of how ALD coating improves the lithium ion diffusion at electrode particles. Paper Ⅱ explains the mechanisms by which 3D electrodes enhance battery performance and reveals guidelines for optimized 3D electrode designs by a 3D electrochemical-mechanical battery model. Paper Ⅲ investigates the electrolyte concentration impact on SEI layer growth and Li plating, especially under high charge rates. Paper Ⅳ proposes an optimized charging protocol for fast charging for reducing the charging time with minimal degradation. Paper Ⅴ reports a comprehensive degradation model for degradation estimation and life predication of energy storage system (ESS). Paper Ⅵ is a study of temperature-dependent state of charge (SOC) estimation for battery pack.

25 ENERGY STORAGE↗

Paired Hydro-Battery Hybrid System Operations Using MIQP Based Multi-Objective Optimization

Hybridizing a hydropower plant with a battery energy storage system is often a very expensive decision. So to make the case for feasibility of hybridization the cost benefit analysis must be comprehensive. Most literature found on this subject only uses one out of many different available value streams to carry out a feasibility analysis. To that end, in this study we propose a multi-objective optimization formulation and a mixed-integer quadratic programming optimization engine that considers multiple different value streams and optimizes hydro-battery hybrid system paired operations to maximize revenue generated from energy arbitrage while simultaneously minimizing the total hydro turbine mileage thus reducing turbine starts and stops and improving turbines life all while following all environmental constraints and not violating any limitations either regulatory or preferential (i.e., to support recreational activities like white water rafting, etc.). In this study we also implemented the developed optimization methodology to a real-world case study of Bagnell dam hydropower facility (8 units totaling 240 MW rated power capacity) which is owned and operated by our industry partner Ameren Energy Inc. The case study outcomes shows that by hybridizing the Bagnell dam hydropower facility with a 60 MW x 2-hr battery energy storage system, the annual benefits can be increased over \$6 million while reducing the annual mileage averaged per turbine and number of start/stops by over 98\% and 85\% respectively.

Chalishazar, Vishvas H.↗

Anomaly Identification of Synchronized Voltage Waveform for Situational Awareness of Low Inertia Systems

Inverter-based resources (IBRs) such as photovoltaics (PVs), wind turbines, and battery energy storage systems (BESSs) are widely deployed in low-carbon power systems. However, these resources typically do not provide the inertia needed for grid stability, resulting in a low-inertia power system. IBRs and lack of inertia have been known to cause anomalies such as waveform distortions and wideband oscillations in power systems due to the limited inertia level, leading to increased generation trips and load shedding. Here, to achieve effective anomaly identification, this paper proposes a synchro-waveform-based algorithm utilizing real-time synchronized voltage waveform measurements from waveform measurement units (WMUs). In the proposed method, different physical characteristics, as well as statistical features, are extracted from synchronized voltage waveform measurements to filter anomalies. Then, the anomaly identification approach based on the random forest is developed and deployed into the FNET/GridEye system considering trade-offs among accuracy, computational burden, and deployment cost. Moreover, four WMUs are specially designed and deployed on Kauai Island to receive instantaneous synchronized voltage waveform measurements. To verify the performance of the proposed algorithm, different experiments are carried out with collected field test data. The result demonstrates that the performance of the proposed synchro-waveform-based anomaly categorization algorithm can accurately identify anomalies 95.35% of the time, which has comparable performance among benchmarking algorithms.

Situational awareness↗

Demonstrating the data center as a flexible grid asset using a C-HIL setup

Increasing data center demand is outpacing grid infrastructure development. Artificial intelligence workloads and hyperscale cloud growth are creating unprecedented demand for power, while traditional grid expansion faces multiyear development timelines. Verrus is developing an innovative datacenter solution for this challenge, data centers that act as active grid-supportive assets rather than passive loads. Our approach integrates a novel grid-aware power flow management system with battery energy storage systems(BESS) into a microgrid-controlled, medium-voltage power distribution architecture that delivers critical capabilities, such as: * Fast response to grid disturbances such over/ under voltage or over/ under frequency * Demand flexibility that can service requests from the utility within 10 s * Uninterrupted transition to islanded operation during grid outages * Continuous uptime assurance for compute loads while maintaining all customer service level agreements. Through Verrus' strategic partnership with the National Renewable Energy Laboratory (NREL), these capabilities were validated using NREL's Advanced Research on Integrated Energy Systems (ARIES) virtual emulation environment to model a 70-MW grid-interactive data center. This paper outlines the design, methodology, and results of this emulated deployment, demonstrating that data centers can provide both critical load resilience and ancillary grid support without compromising uptime requirements. Specifically, we present a digital real time simulation of a 70 MW data center integrated with a physical microgrid controller, and demonstrate the data center response in the event of a grid voltage and frequency event, utility demand response request and utility outage.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermo-hydro-mechanical analysis of subsurface ice-based thermal energy storage

Ice-based thermal energy storage systems are widely utilized for cooling and managing peak electrical demand globally, offering daily or weekly storage capabilities for both individual homes and larger office buildings. However, scaling these systems for district-level cooling or integrating them with renewable energy sources presents challenges, especially in accommodating larger volumes and addressing seasonal storage requirements in densely populated urban areas. This paper proposes a novel solution by evaluating subsurface ice-based thermal energy storage, in which the underground is subjected to seasonal freeze/thaw cycles. However, these cycles may influence ground behavior, affecting pore pressure and inducing ground movement. To systematically investigate these challenges, we enhance the TOUGH-FLAC simulator by integrating water/ice phase change capabilities and updating the effective stress–strain constitutive relation. Both modifications are validated against analytical solutions or experimental data. Through numerical simulations spanning a decade with ten seasonal freeze/thaw cycles, we evaluate the performance and long-term stability of a generic subsurface ice-based thermal energy storage system, considering factors such as ground permeability, freezing pipe spacing, freeze/thaw damage, and glycol solution temperature. The simulations indicate that ice formation induces pore pressure variations that drive seasonal surface heave and settlement, controlled by ground permeability, pipe spacing, and glycol solution temperature, along with tensile and localized shear deformation around freeze pipes. This highlights the need for accurate ground property characterization and geomechanical analysis for subsurface ice-based thermal energy storage.

Ground freezing↗

Satellite power using magnetically suspended flywheel stack

Research activities with magnetically suspended flywheels are reported. The purpose of the effort is to critically examine and further the development of all the key technologies which impact the inertial energy storage system. The results presented discuss the concept of a magnetically suspended flywheel as it applies to a 500 Watt-hour energy storage system. The proposed system is currently under hardware development and is based upon two pancake magnetic bearings arranged in a vertical stack.

Kirk, James A.↗

Satellite power using a magnetically suspended flywheel stack

Research activities with magnetically suspended flywheels are reported. The purpose of the effort is to critically examine and further the development of all the key technologies which impact the inertial energy storage system. The results presented discuss the concept of a magnetically suspended flywheel as it applies to a 500 Watt-hour energy storage system. The proposed system is currently under hardware development and is based upon two pancake magnetic bearings arranged in a vertical stack.

Kirk, James A.↗

A Comprehensive Comparison of Methods for Evaluating Dispatch of Long-Duration Energy Storage in Power Systems Models

Long-duration energy storage (LDES) could play a pivotal role in the transformation of electricity grids with high shares of variable renewable energy (VRE) such as solar and wind. However, the weather-dependent nature of VRE introduces challenges for grid balancing and stability, which LDES - along with short-duration energy storage (SDES) - can help address. However, modeling LDES in production cost models (PCMs) is particularly challenging due to the need for high temporal resolution over extended optimization windows while preserving chronology, which ensures the alignment of energy storage operations with VRE generation over multi-day periods. This report compares traditional dispatch methods with advanced LDES dispatch strategies, such as the extended horizon approach, across different PCM platforms and examines tradeoffs and scalability. The comparison reveals that the traditional 1-day optimization horizon within the PCM leads to inefficient utilization of LDES. In contrast, extending the optimization horizon as much as possible significantly reduces curtailment and improves storage dispatch, especially in renewable-dense systems. There is also promise in using state-of-charge or end volume targets set by an external model, however this requires an additional modeling set and generally increases computational burden. This paper presents a comparison of these various methods in a number of power systems, showing algorithms initially in small test systems and scaling up to large, country-wide simulations. Overall, the research presents the trade-offs of various computational methods and illustrates how LDES may play an essential role in power systems of the future.

14 SOLAR ENERGY↗

Optimizing Grid Regulation With Gravity Storage Systems: A Comparative Analysis With Different Motor Inertias

The integration of renewable energy sources into power grids necessitates solutions for grid support and stability during fluctuations in electricity generation and demand. Gravity energy storage systems (GESS) are emerging as a promising technology for managing the balance between energy supply and demand. However, their capacity to optimize energy flow and offer voltage and frequency regulation amid imbalances in generation and demand is less reported. This paper investigates the control of GESS for optimizing energy flow during voltage and frequency regulation. The study evaluates the regulation capabilities of GESS with different motor inertias during a Texas grid event: one with a high-speed, low-inertia motor and another with a low-speed, high-inertia motor. Results indicate that both GESS scenarios provide fast frequency response by converting potential energy into kinetic energy and vice versa, with a response time of 1.5 s from the frequency variation. This aligns with grid requirements for primary frequency response from traditional synchronous generators and motors with large inertia. Furthermore, a GESS based on a high-inertia motor may be able to operate over a broader range of frequency variations, whereas a low-inertia system may be limited by thermal constraints of the motor.

frequency regulation↗

A Novel Approach for Microencapsulating Salt Hydrate-Based Phase Change Materials

Energy storage technologies, particularly those utilizing phase change materials (PCMs), have gained attention for their high energy density and efficient thermal management. PCMs, which store energy through solid-liquid phase transitions, can efficiently capture and release thermal energy, but face the challenge of leakage during the phase change process. Inorganic PCMs, such as salt hydrates, offer high energy storage capacity, but are difficult to encapsulate due to their corrosive nature. Conventional encapsulation techniques for inorganic PCMs are limited, particularly for scalable applications. In this work, we present an innovative method for the encapsulation of salt hydrate-based inorganic PCMs (CaCl 2 ·6H 2 O) using co-axial electrospinning. The process involves the creation of co-axial fibers, with salt hydrate as the core and polymer (e.g., PVP) as the outer shell, effectively preventing leakage and improving the stability of the PCM. This approach demonstrates the potential for scalable microencapsulation of inorganic PCMs, marking the first report of using co-axial electrospinning for this purpose. This novel technique could contribute to enhancing the performance and applicability of PCMs in thermal energy storage systems and other energy efficiency applications.

36 MATERIALS SCIENCE↗