At least 973 records · Page 54

A Voltage Inference Framework for Real-Time Observability in Active Distribution Grids

Active distribution grids are gaining traction to meet the growing environmental, socio-economic, and sustainability targets. Various advanced smart grid technologies facilitate the integration of Distributed Energy Resources (DERs) by supporting the bi-directional power flow. The limited observability of distribution grids, primarily related to their location at the very edge of power system infrastructure, brings challenges to optimal grid management. Moreover, only a limited number of measurements at regular intervals are usually available. This paper presents a novel inference framework, referred to as “Voltage Inference”, to overcome the observability issues. The proposed framework employs a prediction step based on the Multivariate Taylor series approximation, followed by a corrector step that minimizes the estimation error to infer the otherwise unknown voltages from the available measurements. Furthermore, numerical results on the IEEE 13-bus test feeder validate the accuracy and computational performance of the proposed framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real-Time Regional PV Spinning Reserve Estimator with AGC Look-Ahead Windows

Curtailed PV generation is a zero-marginal cost spinning reserve that can be used for a number of active power control services. However, unlike the traditional spinning reserve providers, i.e., fossil-fueled generators, who have well-defined operating characteristics, e.g., available headroom or potential high limit (PHL), PV plants have by nature variable and uncertain operating characteristics. To ensure the effective coordination between PV plants and the system operator during an active power control event, accurate forecasts of the PV PHL are essential. A novel reference-control grouping based scaling method has been proposed by NREL to estimate the PV PHL in real-time. This work further enhances the methodology by: 1) improving the model accuracy through machine learning; 2) considering look-ahead windows introduced by the computation and communication latencies; 3) applying the method to regional spinning reserve estimation. A significant performance improvement, over 99% of estimation error reduction, has been observed based on real-world data collected by CAISO and PV plant operators.

potential high limit↗

Traffic Signal Control With Adaptive Online-Learning Scheme Using Multiple-Model Neural Networks

This article proposes a new traffic signal control algorithm to deal with unknown-traffic-system uncertainties and reduce delays in vehicle travel time. Unknown-traffic-system dynamics are approximated using a recurrent neural network (NN). To accurately identify the traffic system model, an online-learning scheme is developed to switch among a set of candidate NNs (i.e., multiple-model NNs) based on their estimation errors. Then, a bank of optimal signal-timing controllers is designed based on the online identification of the traffic system. Simulation studies have been carried out for the obtained control strategies using multiple-model NNs, and the desired results have been obtained. Moreover, compared with the widely used actuated traffic signal control schemes, it is shown that the proposed method can reduce vehicle travel delays and improve traffic system robustness.

99 GENERAL AND MISCELLANEOUS↗

A Nonparametric Bayesian Framework for Short-Term Wind Power Probabilistic Forecast

To improve the energy system resilience and economic efficiency, the wind power as a renewable energy starts to be deeply integrated into smart power grids. However, the wind power forecast uncertainty brings operational challenges. In order to provide a reliable guidance on operational decisions, in this paper, we propose a short-term wind power probabilistic forecast. Specifically, to model the rich dynamic behaviors of underlying physical wind power stochastic process occurring in various meteorological conditions, we first introduce an infinite Markov switching autoregressive model. This nonparametric time series model can capture the important properties in the real world data to improve the prediction accuracy. Then, given finite historical data, the posterior distribution of flexible forecast model can correctly quantify the model estimation uncertainty. Built on it, we develop the posterior predictive distribution to rigorously quantify the overall forecasting uncertainty accounting for both inherent stochastic uncertainty and model estimation error. Furthermore, the proposed approach can provide accurate and reliable short-term wind power probabilistic forecast, which can be used to support smart power grids real-time risk management.

17 WIND ENERGY↗

A Space-Filling Visualization Technique for Multivariate Small World Graphs

We introduce an information visualization technique, known as GreenCurve, for large sparse graphs that exhibit small world properties. Our fractal-based design approach uses spatial cues to approximate the node connections and thus eliminates the links between the nodes in the visualization. The paper describes a sophisticated algorithm to order the neighboring nodes of a large sparse graph by solving the Fiedler vector of its graph Laplacian, and then fold the graph nodes into a space-filling fractal curve based on the Fiedler vector. The result is a highly compact visualization that gives a succinct overview of the graph with guaranteed visibility of every graph node. We show in the paper that the GreenCurve technology is (1) theoretically sustainable by introducing an error estimation metric to measure the fidelity of the new graph representation, (2) empirically rigorous by conducting a usability study to investigate its strengths and weaknesses against the traditional graph layout, and (3) pragmatically feasible by applying it to analyze stressed conditions of the large scale electric power grid on the west coast.

99 GENERAL AND MISCELLANEOUS↗

Progressive Tree-Based Compression of Large-Scale Particle Data

Scientific simulations and observations using particles have been creating large datasets that require effective and efficient data reduction to store, transfer, and analyze. However, current approaches either compress only small data well while being inefficient for large data, or handle large data but with insufficient compression. Toward effective and scalable compression/decompression of particle positions, we introduce new kinds of particle hierarchies and corresponding traversal orders that quickly reduce reconstruction error while being fast and low in memory footprint. Our solution to compression of large-scale particle data is a flexible block-based hierarchy that supports progressive, random-access, and error-driven decoding, where error estimation heuristics can be supplied by the user. For low-level node encoding, we introduce new schemes that effectively compress both uniform and densely structured particle distributions. Our proposed methods thus target all three phases of a tree-based particle compression pipeline, namely tree construction, tree traversal, and node encoding. In conclusion, the improved efficacy and flexibility of these methods over existing compressors are demonstrated through extensive experimentation, using a wide range of scientific particle datasets.

97 MATHEMATICS AND COMPUTING↗

A new upper bound for the growth factor in Gaussian elimination with complete pivoting

Abstract The growth factor in Gaussian elimination measures how large the entries of an LU factorization can be relative to the entries of the original matrix. It is a key parameter in error estimates, and one of the most fundamental topics in numerical analysis. We produce an upper bound of for the growth factor in Gaussian elimination with complete pivoting — the first improvement upon Wilkinson's original 1961 bound of .

Bisain, Ankit [Department of Mathematics Massachus↗

Optical functions of uniaxial rutile and anatase (TiO 2 ) revisited

In this study, the optical functions of uniaxial rutile and anatase (TiO2) were determined from 200 to 850 nm (6.2 to 1.46 eV) using several of four optical techniques: (1) standard spectroscopic two-modulator generalized ellipsometry (2-MGE), (2) near-normal-incidence two-modulator generalized ellipsometry microscopy (2-MGEM), (3) Mueller matrix transmission of rutile, and (4) polarized transmission of rutile. The 2-MGE measurements yielded highly accurate values of the dielectric functions and error estimates from 1.46 to 6.2 eV, whereas the polarization-dependent transmission yielded more accurate values of the absorption coefficient below the band edge of rutile. The 2-MGEM also measured the diattenuation, which is related to the birefringence, and other parameters but at near-normal incidence at a single wavelength (577 nm).

36 MATERIALS SCIENCE↗

Optical functions of crystalline and amorphous TeO2

The optical functions of crystalline paratellurite (α-TeO2) and amorphous TeO2 were determined using several optical techniques: (1) standard spectroscopic two-modulator generalized ellipsometry (2-MGE) of paratellurite (200–850 nm, 6.2–1.46 eV), (2) near-normal-incidence two-modulator generalized ellipsometry microscopy (2-MGEM) of paratellurite (577 nm, 2.15 eV), (3) Mueller matrix transmission of paratellurite (320–798 nm, 3.87–1.55 eV), and (4) polarized transmission of paratellurite (323.6–334.3 nm, 3.83–3.71 eV). The 2-MGE measurements yielded highly accurate values of the dielectric functions and error estimates from 1.46 to 6.2 eV for both paratellurite and amorphous TeO2, whereas the polarization-dependent transmission yielded more accurate values of the absorption coefficient below the band edge of paratellurite. The 2-MGEM measured the diattenuation of paratellurite, which is related to the birefringence. Mueller matrix transmission measurements of paratellurite of a (001) cut crystal as a function of angle of incidence were used to determine both the birefringence and the rotary power as a function of photon energy.

Jellison Jr, Gerald [ORNL]↗

How Well Can We Estimate Areal-Averaged Spectral Surface Albedo from Ground-Based Transmission in an Atlantic Coastal Area?

Areal-averaged albedos are particularly difficult to measure in coastal regions, because the surface is not homogenous, consisting of a sharp demarcation between land and water. With this difficulty in mind, we evaluate a simple retrieval of areal-averaged surface albedo using ground-based measurements of atmospheric transmission alone under fully overcast conditions. To illustrate the performance of our retrieval, we find the areal-averaged albedo using measurements from the Multi-Filter Rotating Shadowband Radiometer (MFRSR) at five wavelengths (415, 500, 615, 673, and 870 nm). These MFRSR data are collected at a coastal site in Graciosa Island, Azores supported by the U.S. Department of Energy’s (DOE’s) Atmospheric Radiation Measurement (ARM) Program. The areal-averaged albedos obtained from the MFRSR are compared with collocated and coincident Moderate Resolution Imaging Spectroradiometer (MODIS) white-sky albedo at four nominal wavelengths (470, 560, 670 and 860 nm). These comparisons are made during a 19-month period (June 2009 - December 2010). We also calculate composite-based spectral values of surface albedo by a weighted-average approach using estimated fractions of major surface types observed in an area surrounding this coastal site. Taken as a whole, these three methods of finding albedo show spectral and temporal similarities, and suggest that our simple, transmission-based technique holds promise, but with estimated errors of about ±0.03. Additional work is needed to reduce this uncertainty in areas with inhomogeneous surfaces.

Kassianov, Evgueni I.↗

Application of machine learning to estimate fireball characteristics and their uncertainty from infrared spectral data

Experiments or events involving high explosives (HE) can be monitored remotely by infrared (IR) sensors to gather information about the configuration or materials involved in the device. Researchers at the Air Force Institute of Technology (AFIT) developed a phenomenological model for HE fireball spectra in the IR range that allows for parameters to be extracted from Fourier transform infrared (FTIR) data. This model includes parameters tied to physical characteristics of the fireball: temperature, size, soot, and gas concentrations. Previous works have sought to recover these parameters by the fitting of either whole spectra or select wavenumber bands to this phenomenological model. Difficulties arise due to the complex relationships between the parameters to be fit. Uncertainty quantification of the estimated fireball parameters is also problematic since HE experiments do not have any ground truth information on the parameters. It is suggested that artificial neural network (ANN) based approaches may be well suited to this problem, because of their ability to capture complex and highly nonlinear relationships. As such, this work seeks to explore the efficacy of deep artificial neural networks (DNNs) for this problem of parameter recovery from spectra and to also investigate the uncertainty of recovering the fireball parameters from FTIR data. Networks are designed using the hyperparameter optimization tool Hyperopt and trained/tested on artificial data generated using the phenomenological model developed by AFIT. The results of applying the network to the artificial data set are compared to a physics-based band approach that uses a selected number of bands based on their physical properties. Information on the uncertainty of estimating parameters from remotely sensed experimental data is obtained by treating the accuracy of the DNN model on artificial data as an upper bound and by examining the impact of emissivity due to soot on parameter estimation error; the results for artificial data are likely to be optimistic as compared to recovering parameters from experimental data.

42 ENGINEERING↗

Analytical calculation of central-axis dosimetric data for a dedicated 6-MV radiosurgery linear accelerator

Narrow beams are extensively used in stereotactic radiosurgery. The accuracy of treatment planning dose calculation depends largely on how well the dosimetric data are measured during the machine commissioning. Narrow beams are characterized by the lack of lateral electronic equilibrium. The lateral electronic disequilibrium in the radiation field and detector's finite size are likely to compromise the accuracy in dose measurements in these beams. This may have a profound impact on outcome in patients who undergo stereotactic radiosurgery. To confirm the measured commissioning data for a dedicated 6-MV linear accelerator-based radiosurgery system, we developed an analytical model to calculate the narrow photon beam central-axis dose. This model is an extension of a previously reported method of Nizin and Mooij for the calculation of the absorbed dose under lateral electronic disequilibrium conditions at depth of d{sub max} or greater. The scatter factor and tissue-maximum ratio were calculated for narrow beams using the parametrized model and compared to carefully measured results for the same beams. For narrow beam radii ranging from 0.2 to 1.5 cm, the differences between the analytical and measured scatter factors were no greater than 1.4%. In addition, the differences between the analytical and measured tissue-maximum ratios were within 3.3% for regions greater than the maximum dose depth. The estimated error of this analytical calculation was less than 2%, which is sufficient to validate measurement results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Registration of prone and supine CT colonography scans using correlation optimized warping and canonical correlation analysis

Purpose: In computed tomographic colonography (CTC), a patient will be scanned twice--Once supine and once prone--to improve the sensitivity for polyp detection. To assist radiologists in CTC reading, in this paper we propose an automated method for colon registration from supine and prone CTC scans. Methods: We propose a new colon centerline registration method for prone and supine CTC scans using correlation optimized warping (COW) and canonical correlation analysis (CCA) based on the anatomical structure of the colon. Four anatomical salient points on the colon are first automatically distinguished. Then correlation optimized warping is applied to the segments defined by the anatomical landmarks to improve the global registration based on local correlation of segments. The COW method was modified by embedding canonical correlation analysis to allow multiple features along the colon centerline to be used in our implementation. Results: We tested the COW algorithm on a CTC data set of 39 patients with 39 polyps (19 training and 20 test cases) to verify the effectiveness of the proposed COW registration method. Experimental results on the test set show that the COW method significantly reduces the average estimation error in a polyp location between supine and prone scans by 67.6%, from 46.27{+-}52.97 to 14.98 mm{+-}11.41 mm, compared to the normalized distance along the colon centerline algorithm (p<0.01). Conclusions: The proposed COW algorithm is more accurate for the colon centerline registration compared to the normalized distance along the colon centerline method and the dynamic time warping method. Comparison results showed that the feature combination of z-coordinate and curvature achieved lowest registration error compared to the other feature combinations used by COW. The proposed method is tolerant to centerline errors because anatomical landmarks help prevent the propagation of errors across the entire colon centerline.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Response of TLD-100 in mixed fields of photons and electrons

Purpose: Thermoluminescent dosimeters (TLDs) are routinely used for dosimetric measurements of high energy photon and electron fields. However, TLD response in combined fields of photon and electron beam qualities has not been characterized. This work investigates the response of TLD-100 (LiF:Mg,Ti) to sequential irradiation by high-energy photon and electron beam qualities. Methods: TLDs were irradiated to a known dose by a linear accelerator with a 6 MV photon beam, a 6 MeV electron beam, and a NIST-traceable {sup 60}Co beam. TLDs were also irradiated in a mixed field of the 6 MeV electron beam and the 6 MV photon beam. The average TLD response per unit dose of the TLDs for each linac beam quality was normalized to the average response per unit dose of the TLDs irradiated by the {sup 60}Co beam. Irradiations were performed in water and in a Virtual Water Trade-Mark-Sign phantom. The 6 MV photon beam and 6 MeV electron beam were used to create dose calibration curves relating TLD response to absorbed dose to water, which were applied to the TLDs irradiated in the mixed field. Results: TLD relative response per unit dose in the mixed field was less sensitive than the relative response in the photon field and more sensitive than the relative response in the electron field. Application of the photon dose calibration curve to the TLDs irradiated in a mixed field resulted in an underestimation of the delivered dose, while application of the electron dose calibration curve resulted in an overestimation of the dose. Conclusions: The relative response of TLD-100 in mixed fields fell between the relative response in the photon-only and electron-only fields. TLD-100 dosimetry of mixed fields must account for this intermediate response to minimize the estimation errors associated with calibration factors obtained from a single beam quality.

60 APPLIED LIFE SCIENCES↗

A unified statistical framework for material decomposition using multienergy photon counting x-ray detectors

Purpose: Material decomposition using multienergy photon counting x-ray detectors (PCXD) has been an active research area over the past few years. Even with some success, the problem of optimal energy selection and three material decomposition including malignant tissue is still on going research topic, and more systematic studies are required. This paper aims to address this in a unified statistical framework in a mammographic environment.Methods: A unified statistical framework for energy level optimization and decomposition of three materials is proposed. In particular, an energy level optimization algorithm is derived using the theory of the minimum variance unbiased estimator, and an iterative algorithm is proposed for material composition as well as system parameter estimation under the unified statistical estimation framework. To verify the performance of the proposed algorithm, the authors performed simulation studies as well as real experiments using physical breast phantom and ex vivo breast specimen. Quantitative comparisons using various performance measures were conducted, and qualitative performance evaluations for ex vivo breast specimen were also performed by comparing the ground-truth malignant tissue areas identified by radiologists.Results: Both simulation and real experiments confirmed that the optimized energy bins by the proposed method allow better material decomposition quality. Moreover, for the specimen thickness estimation errors up to 2 mm, the proposed method provides good reconstruction results in both simulation and real ex vivo breast phantom experiments compared to existing methods.Conclusions: The proposed statistical framework of PCXD has been successfully applied for the energy optimization and decomposition of three material in a mammographic environment. Experimental results using the physical breast phantom and ex vivo specimen support the practicality of the proposed algorithm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combined iterative reconstruction and image-domain decomposition for dual energy CT using total-variation regularization

Purpose: Dual-energy CT (DECT) is being increasingly used for its capability of material decomposition and energy-selective imaging. A generic problem of DECT, however, is that the decomposition process is unstable in the sense that the relative magnitude of decomposed signals is reduced due to signal cancellation while the image noise is accumulating from the two CT images of independent scans. Direct image decomposition, therefore, leads to severe degradation of signal-to-noise ratio on the resultant images. Existing noise suppression techniques are typically implemented in DECT with the procedures of reconstruction and decomposition performed independently, which do not explore the statistical properties of decomposed images during the reconstruction for noise reduction. In this work, the authors propose an iterative approach that combines the reconstruction and the signal decomposition procedures to minimize the DECT image noise without noticeable loss of resolution. Methods: The proposed algorithm is formulated as an optimization problem, which balances the data fidelity and total variation of decomposed images in one framework, and the decomposition step is carried out iteratively together with reconstruction. The noise in the CT images from the proposed algorithm becomes well correlated even though the noise of the raw projections is independent on the two CT scans. Due to this feature, the proposed algorithm avoids noise accumulation during the decomposition process. The authors evaluate the method performance on noise suppression and spatial resolution using phantom studies and compare the algorithm with conventional denoising approaches as well as combined iterative reconstruction methods with different forms of regularization. Results: On the Catphan©600 phantom, the proposed method outperforms the existing denoising methods on preserving spatial resolution at the same level of noise suppression, i.e., a reduction of noise standard deviation by one order of magnitude. This improvement is mainly attributed to the high noise correlation in the CT images reconstructed by the proposed algorithm. Iterative reconstruction using different regularization, including quadratic orq-generalized Gaussian Markov random field regularization, achieves similar noise suppression from high noise correlation. However, the proposed TV regularization obtains a better edge preserving performance. Studies of electron density measurement also show that our method reduces the average estimation error from 9.5% to 7.1%. On the anthropomorphic head phantom, the proposed method suppresses the noise standard deviation of the decomposed images by a factor of ∼14 without blurring the fine structures in the sinus area. Conclusions: The authors propose a practical method for DECT imaging reconstruction, which combines the image reconstruction and material decomposition into one optimization framework. Compared to the existing approaches, our method achieves a superior performance on DECT imaging with respect to decomposition accuracy, noise reduction, and spatial resolution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A general framework of noise suppression in material decomposition for dual-energy CT

Purpose: As a general problem of dual-energy CT (DECT), noise amplification in material decomposition severely reduces the signal-to-noise ratio on the decomposed images compared to that on the original CT images. In this work, the authors propose a general framework of noise suppression in material decomposition for DECT. The method is based on an iterative algorithm recently developed in their group for image-domain decomposition of DECT, with an extension to include nonlinear decomposition models. The generalized framework of iterative DECT decomposition enables beam-hardening correction with simultaneous noise suppression, which improves the clinical benefits of DECT. Methods: The authors propose to suppress noise on the decomposed images of DECT using convex optimization, which is formulated in the form of least-squares estimation with smoothness regularization. Based on the design principles of a best linear unbiased estimator, the authors include the inverse of the estimated variance–covariance matrix of the decomposed images as the penalty weight in the least-squares term. Analytical formulas are derived to compute the variance–covariance matrix for decomposed images with general-form numerical or analytical decomposition. As a demonstration, the authors implement the proposed algorithm on phantom data using an empirical polynomial function of decomposition measured on a calibration scan. The polynomial coefficients are determined from the projection data acquired on a wedge phantom, and the signal decomposition is performed in the projection domain. Results: On the Catphan{sup ®}600 phantom, the proposed noise suppression method reduces the average noise standard deviation of basis material images by one to two orders of magnitude, with a superior performance on spatial resolution as shown in comparisons of line-pair images and modulation transfer function measurements. On the synthesized monoenergetic CT images, the noise standard deviation is reduced by a factor of 2–3. By using nonlinear decomposition on projections, the authors’ method effectively suppresses the streaking artifacts of beam hardening and obtains more uniform images than their previous approach based on a linear model. Similar performance of noise suppression is observed in the results of an anthropomorphic head phantom and a pediatric chest phantom generated by the proposed method. With beam-hardening correction enabled by their approach, the image spatial nonuniformity on the head phantom is reduced from around 10% on the original CT images to 4.9% on the synthesized monoenergetic CT image. On the pediatric chest phantom, their method suppresses image noise standard deviation by a factor of around 7.5, and compared with linear decomposition, it reduces the estimation error of electron densities from 33.3% to 8.6%. Conclusions: The authors propose a general framework of noise suppression in material decomposition for DECT. Phantom studies have shown the proposed method improves the image uniformity and the accuracy of electron density measurements by effective beam-hardening correction and reduces noise level without noticeable resolution loss.

60 APPLIED LIFE SCIENCES↗

Experimental verification of gain drop due to general ion recombination for a carbon-ion pencil beam

Purpose: Accurate dose measurement in radiotherapy is critically dependent on correction for gain drop, which is the difference of the measured current from the ideal saturation current due to general ion recombination. Although a correction method based on the Boag theory has been employed, the theory assumes that ionized charge density in an ionization chamber (IC) is spatially uniform throughout the irradiation volume. For particle pencil beam scanning, however, the charge density is not uniform, because the fluence distribution of a pencil beam is not uniform. The aim of this study was to verify the effect of the nonuniformity of ionized charge density on the gain drop due to general ion recombination. Methods: The authors measured the saturation curve, namely, the applied voltage versus measured current, using a large plane-parallel IC and 24-channel parallel-plate IC with concentric electrodes. To verify the effect of the nonuniform ionized charge density on the measured saturation curve, the authors calculated the saturation curve using a method which takes into account the nonuniform ionized charge density and compared it with the measured saturation curves. Results: Measurement values of the different saturation curves in the different channels of the concentric electrodes differed and were consistent with the calculated values. The saturation curves measured by the large plane-parallel IC were also consistent with the calculation results, including the estimation error of beam size and of setup misalignment. Although the impact of the nonuniform ionized charge density on the gain drop was clinically negligible with the conventional beam intensity, it was expected that the impact would increase with higher ionized charge density. Conclusions: For pencil beam scanning, the assumption of the conventional Boag theory is not valid. Furthermore, the nonuniform ionized charge density affects the prediction accuracy of gain drop when the ionized charge density is increased by a higher dose rate and/or lower beam size.

61 RADIATION PROTECTION AND DOSIMETRY↗