Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUID MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Comment on “Brownian motion of droplets induced by thermal noise”

We simulate phase separated fluids using the Cahn-Hillard fluctuating hydrodynamic (CH-FHD) model and measure the statistical properties of capillary waves generated by thermal fluctuations. Our measurements are in good agreement with stochastic lubrication theory and molecular dynamics simulations but differ significantly from recent CH-FHD results by Zhang et al. [Phys. Rev. E 109, 024208 (2024)2470-004510.1103/PhysRevE.109.024208]. Specifically, we find that capillary wave statistics at thermodynamic equilibrium are independent of transport properties, namely viscosity and species diffusion.

Bell, J B↗

Temperature elevation by HIFU in ex vivo porcine muscle: MRI measurement and simulation study

Purpose: High-intensity focused ultrasound is a rapidly developing medical technology with a large number of potential clinical applications. Computational model can play a pivotal role in the planning and optimization of the treatment based on the patient's image. Nonlinear propagation effects can significantly affect the temperature elevation and should be taken into account. In order to investigate the importance of nonlinear propagation effects, nonlinear Westervelt equation was solved. Weak nonlinear propagation effects were studied. The purpose of this study was to investigate the correlation between the predicted and measured temperature elevations and lesion in a porcine muscle. Methods: The investigated single-element transducer has a focal length of 12 cm, an aperture of 8 cm, and frequency of 1.08 MHz. Porcine muscle was heated for 30 s by focused ultrasound transducer with an acoustic power in the range of 24–56 W. The theoretical model consists of nonlinear Westervelt equation with relaxation effects being taken into account and Pennes bioheat equation. Results: Excellent agreement between the measured and simulated temperature rises was found. For peak temperatures above 85–90 °C “preboiling” or cavitation activity appears and lesion distortion starts, causing small discrepancy between the measured and simulated temperature rises. From the measurements and simulations, it was shown that distortion of the lesion was caused by the “preboiling” activity. Conclusions: The present study demonstrated that for peak temperatures below 85–90 °C numerical simulation results are in excellent agreement with the experimental data in three dimensions. Both temperature rise and lesion size can be well predicted. Due to nonlinear effect the temperature in the focal region can be increased compared with the linear case. The current magnetic resonance imaging (MRI) resolution is not sufficient. Due to the inevitable averaging the measured temperature can be 10–30 °C lower than the peak temperature. Computational fluid dynamics can provide additional important information that is lost using a state of the art MRI device.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-speed, two-dimensional synchrotron white-beam x-ray radiography of spray breakup and atomization

High-speed, two-dimensional synchrotron x-ray radiography and phase-contrast imaging are demonstrated in propulsion sprays. Measurements are performed at the 7-BM beamline at the Advanced Photon Source user facility at Argonne National Laboratory using a recently developed broadband x-ray white beam. This novel enhancement allows for high speed, high fidelity x-ray imaging for the community at large. Quantitative path-integrated liquid distributions and spatio-temporal dynamics of the sprays were imaged with a LuAG:Ce scintillator optically coupled to a high-speed CMOS camera. Images are collected with a microscope objective at frame rates of 20 kHz and with a macro lens at 120 kHz, achieving spatial resolutions of 12 μm and 65 μm, respectively. Imaging with and without potassium iodide (KI) as a contrast-enhancing agent is compared, and the effects of broadband attenuation and spatial beam characteristics are determined through modeling and experimental calibration. In addition, phase contrast is used to differentiate liquid streams with varying concentrations of KI. The experimental approach is applied to different spray conditions, including quantitative measurements of mass distribution during primary atomization and qualitative visualization of turbulent binary fluid mixing. High-speed, two-dimensional synchrotron white-beam x-ray radiography of spray breakup and atomization. Available from: https://www.researchgate.net/publication/312567827_High-speed_two-dimensional_synchrotron_white-beam_x-ray_radiography_of_spray_breakup_and_atomization [accessed Aug 31, 2017].

Halls, Benjamin R.↗

Monitoring the Subsurface with Quasi-Static Deformation

This project consisted of three sub-projects that are all aimed at monitoring the subsurface with geophysical methods. The objectives of these sub-projects are: to investigate the use of seismic waves for remote monitoring of temperature changes in the Yucca Mountain nuclear repository; to investigate the use of measured changes in the tidal tilt as a diagnostic for the infiltration of fluids in the subsurface; and to extract the electrostatic response from dynamic field fluctuations.

58 GEOSCIENCES↗

Multidisciplinary Design of an Innovative Natural Draft, Forced Diffusion Cookstove for Woody and Herbaceous Biomass Fuels in East Africa

The goal of the project was to develop a commercially viable, natural draft cookstove that exceeds ISO tier 4 criteria while meeting the needs of rural and urban cooks in East Africa. The cookstove should be market ready that meets the manufacturing cost and usability expectations of the final users, including durability, safety, comfort, aspirational value and compatibility with local fuels, foods, and customs. The cleaner burning cookstove product was designed to replace open fires and inefficient stoves so that it can enhance indoor air quality, personal health, livelihoods, and the environment. The stove was developed using integrated and multidisciplinary design approach that included field based user research and focus groups, empirically verified computational fluid dynamics and heat transfer modeling, lab and field based emission and efficiency measurements, design for manufacturability, as well as in-home user product evaluations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Durability of Piston Seals in Hydraulic Power Take-off Systems in Wave Energy Converters

Hydraulic cylinder seals are a critical component of hydraulic power take-off (PTO) systems in wave energy converters (WECs). Primary hydraulic piston seal wear is a major concern for the longevity of hydraulic PTOs, especially in the context of the effort and expense associated with seal replacement. Piston seals, made from polymeric elastomers, are used to contain and isolate high pressure fluids within PTO systems. A specific challenge for WEC designers is knowing, with confidence, the relative expected lifetimes of commercially available seals and seal materials for the unique long travel and continuous use case of WEC hydraulic systems. This information is critical to accurately determine operating expense (OPEX) and levelized cost of electricity (LCOE). If failures of seals occur earlier than their designed lifetime, the estimated operations, and maintenance (O&M) and LCOE costs may double based on estimation. Unfortunately, information from seal manufacturers on longevity in these applications is not generally available and quantitative performance comparison between different manufacturers is not available, creating significant uncertainty on use of hydraulic PTO system in wave power generation. In this project, PNNL, with advice from different WEC device and seal manufacturers, has created a framework to address the industry need for available, dependable and comparative data for seals and seals materials for WEC hydraulic applications including piston seals, glide rings, and shaft seals. Commonly used and candidate seal materials were identified and available information on the materials such as mechanical and fatigue performance, chemical (fluid) compatibility, and cost has been compiled. Hardware and strategy for bench scale measurement of key materials and seal performance and pathway for publicly available library of hydraulic seal materials, properties, suppliers, and options have also been identified for future implementation. The results of this project were presented at WPTO Seedling Symposium 2023 and OCEANS 2023. The results of the literature review including identified polymer seals and ideal operating conditions were summaried and compiled to a database WEC-SealsDB hosted locally at PNNL.

16 TIDAL AND WAVE POWER↗

Quantitative Assessment of Parent Well Effect on Hydraulic Fracture Propagation at HFTS2: Insights from Cross-Well Strain Measurements and Microseismic Data

Understanding fracture propagation behavior is essential for optimizing hydraulic fracturing in unconventional reservoirs. This study demonstrates the value of integrating Low-Frequency Distributed Acoustic Sensing (LF-DAS) and microseismic data, which together provide a more complete picture of fracture growth. Using data from Hydraulic Fracturing Test Site 2 (HFTS2), we identify stress changes in depletion zones induced by parent wells as a key factor influencing fracture propagation. This result is shown by new measurements of in-situ fracture propagation velocity and fracture-hit volume (fluid volume at fracture hit?) from LF-DAS and event density from microseismic. These findings highlight the importance of considering parent well effects, well spacing, and stimulation sequencing in completion design to improve reservoir development and production efficiency.

depletion zones↗

Pulse Jet Mixer Overblow Testing for Assessment of Loadings During Multiple Overblows

The U.S. Department of Energy (DOE) Office of River Protection’s Waste Treatment Plant (WTP) is being designed and built to pretreat and then vitrify a large portion of the wastes in Hanford’s 177 underground waste storage tanks. The WTP consists of three primary facilities: pretreatment, low-activity waste (LAW) vitrification, and high-level waste (HLW) vitrification. The pretreatment facility will receive waste feed from the Hanford tank farms and separate it into 1) a high-volume, low-activity liquid stream stripped of most solids and radionuclides and 2) a much smaller volume of HLW slurry containing most of the solids and most of the radioactivity. Many of the vessels in the pretreatment facility will contain pulse jet mixers (PJMs) that will provide some or all of the mixing in the vessels. This technology was selected for use in so-called “black cell” regions of the WTP, where maintenance capability will not be available for the operating life of the WTP. PJM technology was selected for use in these regions because it has no moving mechanical parts that require maintenance. The vessels with the most concentrated slurries will also be mixed with air spargers and/or steady jets in addition to the mixing provided by the PJMs. This report contains the results of single and multiple PJM overblow tests conducted in a large, ~13 ft-diameter × 15-ft-tall tank located in the high bay of the Pacific Northwest National Laboratory (PNNL) 336 Building test facility. These single and multiple PJM overblow tests were conducted using water and a clay simulant to bound the lower and upper rheological properties of the waste streams anticipated to be processed in the WTP. Hydrodynamic pressures were measured at a number of locations in the test vessel using an array of nine pressure sensors and four hydrophones. These measurements were made under normal and limiting vessel operating conditions (i.e., maximum PJM fluid emptying velocity, maximum and minimum vessel contents for PJM operation, and maximum and minimum rheological properties). Test data collected from the PJM overblow tests were provided to Bechtel National, Inc. (BNI) for assessing hydrostatic, dynamic, and acoustic pressure loadings on in-tank structures during 1) single overblows; 2) multiple overlapping overblows of two to four PJMs; 3) simultaneous overblows of pairs of PJMs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The U-tube: A new paradigm in borehole fluid sampling

Fluid samples from deep boreholes can provide insights into subsurface physical, chemical, and biological conditions. Recovery of intact, minimally altered aliquots of subsurface fluids is required for analysis of aqueous chemistry, isotopic composition, and dissolved gases, and for microbial community characterization. Unfortunately, for many reasons, collecting geofluids poses a number of challenges, from formation contamination by drilling to maintaining integrity during recovery from depths. Not only are there substantial engineering issues in retrieval of a representative sample, but there is often the practical reality that fluid sampling is just one of many activities planned for deep boreholes. The U-tube geochemical sampling system presents a new paradigm for deep borehole fluid sampling. Because the system is small, its ability to integrate with other measurement systems and technologies opens up numerous possibilities for multifunctional integrated wellbore completions. To date, the U-tube has been successfully deployed at four different field sites, each with a different deployment modality, at depths from 260 m to 2 km. While the U-tube has proven to be highly versatile, these installations have resulted in data that provide additional insights for improving future U-tube deployments.

54 ENVIRONMENTAL SCIENCES↗

Large Eddy Simulation of turbulent flow in rod bundle with spacer grids

Pressurized water nuclear reactor fuel assemblies are made of fuel rods held by spacer grids, which are the core components of the nuclear power plants. Hot fuel rods are cooled by the coolant water flow, and the spacer grids with mixing vanes distort the mainstream, producing the swirling flow which can enhance the heat transfer to improve CHF (Critical Heat Flux). Heat transfer between fuel rods and coolant is a crucial part of thermal-hydraulic analysis. For the purpose to improve the thermal hydraulic performance of the fuel assemblies, many experiments have been conducted to understand the flow structures and three-dimensional behaviors of the turbulence in the rod bundle sub-channels and then to optimize the design of the spacer grid. In the experimental work, which requires lots of efforts to get reliable data, LDA (Laser Doppler Anemometry) and PIV (Particle Image Velocimetry) are generally used to measure the velocity profile and turbulent intensity in the sub-channels. Computational Fluid Dynamics (CFD) is another useful way to study the characteristics of the detailed flow condition and heat transfer phenomena in the subchannels. The main issue of the single-phase CFD is to accurately predict the flow and turbulence characteristics. RANS method is generally used to simulate the induced lateral velocity and the heat transfer process. With the development of computer technology, some more precise but previously time-consuming turbulent models, such as LES (Large Eddy Simulation), are gradually used for the simulation of rod bundle flow with current advanced CPU resources. Ikeno and Kajishima explained the decay of swirling turbulent flow in the rod bundle using LES method. Benhamadouche acquired the turbulence induced forces on the central rod of the rod bundle through performing the LES of the flow downstream the spacer grid. Chang and Tavoularis conducted hybrid simulations with SAS SST and LES of a 5 x 5 rod bundle, and several vortices were identified in the vicinity of the vanes and the generation mechanisms, evolution progress and influence on the velocities of these vortices were clarified. In the paper we present CFD simulations of turbulent flow in rod bundle sub-channels with spacer grids of two different experiments. One is MATiS-H benchmark experiment with scaled spacer grids, which is conducted by KAERI, and is used as a CFD benchmark test, and the other is a 5 x 5 rod bundle with typical spacer grids using PIV technology, with the cooperation of Harbin Engineering University. The main objectives of the calculations are to validate LES methodology by the benchmark experiments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-resolution wall temperature measurements with distributed fiber optic sensors

Conventional approaches of surface temperature measurement are often unreliable, and other methods may not be practical in closed, high-temperature spaces. In this study, surface temperature measurements of the cooling panel of a natural circulation facility were performed with fiber optic distributed temperature sensors (DTS). High resolution surface temperature profiles of the cooling panel were acquired under two steady experimental conditions, and compared with measurements performed with nearby thermocouples. The total measurement error of the DTS results presented has been estimated to be ±4.4 °C. The findings reflected herein show that these DTS can reasonably measure surface temperature when installed with the methods developed in this study. Through the analysis of the DTS data collected, the interesting behavior of the cooling panel was revealed, providing new insights on the system's behavior that may be beneficial to the design and optimization of such heat transfer devices. These sensors can also provide the measurement density necessary for validation efforts with highly-resolved prediction methods such as finite element analysis (FEA) or computational fluid dynamics (CFD).

47 OTHER INSTRUMENTATION↗

Center for Extended Magnetohydrodynamic Modeling (CEMM, UW-Madison Physics)

The Center for Extended Magnetohydrodynamic Modeling (CEMM) focused on the further development, verification, validation, and application of two scientific computation programs, the NIMROD and M3D-C1 codes, for modeling macroscopic dynamics in magnetized plasma. Both NIMROD and M3D-C1 solve the mathematical equations that model two-fluid 3D magnetohydrodynamic (MHD). They are designed and optimized to be efficient and accurate for toroidal confinement physics calculations. The effort improved the fidelity of the physics models, the realism of the treatment of the surrounding vessel, coils, and other structures, the accuracy and efficiency of the algorithms, and the ability to scale calculations to thousands of processors in order to take advantage of leading-edge computers. The primary application areas of Resonant Magnetic Perturbations (RMP), Edge Harmonic Oscillations (EHO), Edge Localized Modes (ELMs), Disruption Studies, Sawteeth and Stationary States, and Kinetic MHD and Neoclassical Tearing Modes (NTM) are of concern for the international ITER experiment, which is under construction in France. The component of CEMM that is described in this report applied recently developed aspects of NIMROD to sawtooth and EHO dynamics, which occur in tokamak plasma confinement systems. In particular, the effort researched energetic-particle, two-fluid, and plasma-flow effects. The work included an effort to validate energetic-particle modeling using laboratory measurements and previous analysis of giant sawtooth oscillations, where energetic particles temporarily stabilize the system. A side effort that grew out of this work was benchmarking of the slab-geometry ion temperature gradient (ITG) instability computed by NIMROD's two-fluid modeling against analytical results. These fluid-model results were also compared with results from kinetic modeling to help quantify the range of validity for the two-fluid model. The EHO simulations show that sheared plasma flow plays a crucial role in saturating the underlying MHD instability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dispersion stabilization of silver nanoparticles in synthetic lung fluid studied under in situ conditions

The dispersion stabilization of silver nanoparticles (AgNPs) in synthetic lung fluid was studied to interrogate the effects on colloidal stability due to the principal constituents of the fluid. The colloidal stability of 20 nm citrate-AgNPs dispersed in the presence of each constituent of the synthetic lung fluid (individually, the complete fluid, and without additives) was observed during titration of increasing sodium chloride concentration. A variety of complementary in situ measurement techniques were utilized, including dynamic light scattering, ultraviolet-visible absorption spectroscopy, atomic force microscopy, and small-angle X-ray scattering, which provided a collective set of information that enabled far better understanding of the dispersion behavior in the fluid than any one technique alone. It was observed that AgNPs continued to adsorb bovine serum albumin (BSA) protein from the synthetic lung fluid solution as the sodium chloride concentration increased, until a maximum BSA coating was achieved prior to reaching the physiological sodium chloride concentration of 154 mmol L{sup -1}. BSA was determined to be the constituent of the synthetic lung fluid that is required to provide colloidal stability at high salt loadings, though the phospholipid constituent exerts a subtle effect. Additionally, as AgNPs are a distinctly different class of nanoparticles apart from the carbon nanotubes and titanium dioxide nanoparticles initially reported to be dispersible using this fluid, this work also demonstrates the broad applicability of synthetic lung fluid in providing stable dispersions for engineered nanoparticles for use in biological assays.

59 BASIC BIOLOGICAL SCIENCES↗

EXPERIMENTAL ANALYSIS OF SINGLE EVAPORATION TUBE UTILIZING SINTERED COPPER PARTICLE WICKING STRUCTURES

Wicking structures have been widely used within passive heat transfer devices with high heat fluxes, such as heat pipes, to enhance their thermal performance. While wicking structures promote capillary pumping of the working fluid as well as thin film evaporation, they can result in capillary evaporation and further enhances the evaporation heat transfer. In this study, a 0.5 mm thick layer of 105 microns sintered copper particles was added to the inner wall of a copper tube, aiming to enhance the heat transfer characteristics by taking advantage of capillary evaporation. Acetone was chosen as the working fluid, and the performance of an evaporation tube was tested for power inputs of 10, 30, 50, and 70 W. For each power input, trials were run at inclination angles varying from -90° and 90° to investigate the capillary effects. The temperature measurements showed that the temperature distribution along the evaporation tube is always downward sloping, meaning the temperature at the fluid inlet is larger than the outlet. Interestingly, the surface temperature at some locations is less than the outlet temperature, indicating the effect of capillary evaporation. In addition, a theoretical investigation was performed to investigate the effects of the particle size on the thermal performance of the evaporation tube and found that particle sizes affect capillary evaporation.

Wang, Pengtao↗

Undercooling minimization in ultrasound coupled DTA measurements of molten salts

Molten salts are ionic liquids that are used for the electrolytic pyroprocessing of metals and as heat transfer fluids in very high temperature processes. Recently, halide-based molten salt reactors (MSR) have gained momentum for high density and environmentally responsible electricity generation. The function of these reactors and their fuel cycle depend on a knowledge of the halide salt’s thermodynamic properties [1]. Therefore, high accuracy phase equilibria of MSR relevant base halide and actinide containing salts are needed. Modern thermal analysis of the phase transitions of halide salts is usually done during heating at relatively high scan rates with commercial devices. Normally such measurements are adequate for pure or pseudo-binary salts. However, as the number of components in the mixture increases, accurately resolving the liquidus becomes increasingly difficult. Reversing the scanning mode greatly increases the sensitivity of phase transition measurements but can decrease accuracy due to undercooling [2] — a common occurrence in molten halide systems [3]. This work presents the development of a differential thermal analysis (DTA) cell intended for use in radiological gloveboxes. Non-contact ultrasonic agitation of the halide salt is implemented to limit kinetic limitations on crystallization during cooling to minimize undercooling [4]. Measurements on halide salts are also presented to elucidate the effect of non-contact mixing on undercooling. Reference [1] S. Boyd and C. Taylor, “3 - Chemical fundamentals and applications of molten salts,” in Molten Salt Reactors and Thorium Energy, T. J. Dolan, Ed., Woodhead Publishing, 2017, pp. 29–91. doi: 10.1016/B978-0-08-101126-3.00003-8. [2] K. Nitsch, A. Cihlár, and M. Rodová, “Molten state and supercooling of lead halides,” J. Cryst. Growth, vol. 264, no. 1, pp. 492–498, Mar. 2004, doi: 10.1016/j.jcrysgro.2004.01.011. [3] L. Rycerz, “Practical remarks concerning phase diagrams determination on the basis of differential scanning calorimetry measurements,” J. Therm. Anal. Calorim., vol. 113, no. 1, pp. 231–238, Jul. 2013, doi: 10.1007/s10973-013-3097-0. [4] Md. H. Zahir, S. A. Mohamed, R. Saidur, and F. A. Al-Sulaiman, “Supercooling of phase-change materials and the techniques used to mitigate the phenomenon,” Appl. Energy, vol. 240, pp. 793–817, Apr. 2019, doi: 10.1016/j.apenergy.2019.02.045.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of A Multi-Spectral Pyrometry Sensor for High-Speed Transient Surface-Temperature Measurements in Combustion-Relevant Harsh Environments

Accurate and high-speed transient surface-temperature measurements of combustion devices including internal combustion (IC) engines, gas turbines, etc., provide validation targets and boundary conditions for computational fluid dynamics models, and are broadly relevant to technology advancements such as performance improvement and emissions reduction. Development and demonstration of a multi-infrared-channel pyrometry-based optical instrument for high-speed surface-temperature measurement is described. The measurement principle is based on multi-spectral radiation thermometry (MRT) and uses surface thermal radiation at four discrete spectral regions and a corresponding emissivity model to obtain surface temperature via non-linear least squares (NLLS) optimization. Rules of thumb for specifying the spectral regions and considerations to avoid interference with common combustion products are developed; the impact of these along with linear and non-linear MRT analysis are assessed as a function of temperature and signal-to-noise ratio. A multi-start method to determine the MRT-solution global optimum is described and demonstrated. The resulting multi-channel transient pyrometry instrument is described along with practical considerations including optical-alignment drift, matching intra-channel transient response, and solution-confidence indicators. The instrument demonstrated excellent >97% accuracy and >99% 2-sigma precision over the 400–800 °C range, with ~20 µs (50 kHz, equivalent to 0.2 cad at 2000 RPM IC-engine operation) transient response in the bench validation.

47 OTHER INSTRUMENTATION↗

Capturing Pressure Oscillations in Numerical Simulations of Internal Combustion Engines

In an earlier publication, the authors compared numerical predictions of the mean cylinder pressure of diesel and dual-fuel combustion, to that of measured pressure data from a medium-speed, large-bore engine. In these earlier comparisons, measured data from a flush-mounted in-cylinder pressure transducer showed notable and repeatable pressure oscillations which were not evident in the mean cylinder pressure predictions from computational fluid dynamics (CFD). In this paper, the authors present a methodology for predicting and reporting the local cylinder pressure consistent with that of a measurement location. Such predictions for large-bore, medium-speed engine operation demonstrate pressure oscillations in accordance with those measured. The temporal occurrences of notable pressure oscillations were during the start of combustion and around the time of maximum cylinder pressure. With appropriate resolutions in time steps and mesh sizes, the local cell static pressure predicted for the transducer location showed oscillations in both diesel and dual-fuel combustion modes which agreed with those observed in the experimental data. Fast Fourier transform (FFT) analysis on both experimental and calculated pressure traces revealed that the CFD predictions successfully captured both the amplitude and frequency range of the oscillations. Furthermore, resolving propagating pressure waves with the smaller time steps and grid sizes necessary to achieve these results required a significant increase in computer resources.

33 ADVANCED PROPULSION SYSTEMS↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗