DOE OSTI2019
This report provides analyses of glass compositions, wash solution compositions, and Product Consistency Test (PCT) leachate compositions for a series of simulated low-activity waste (LAW) glasses fabricated at the Pacific Northwest National Laboratory (PNNL). These data will be used in the development of improved property/composition models for LAW glass at Hanford. Chemical analyses were performed on a representative sample of each of the quenched and sulfur saturated glasses to allow for comparisons with the targeted compositions. For some of the quenched glasses, measured concentrations of Cr 2 O 3 , K 2 O, Na 2 O, P 2 O 5 , and ZrO 2 were below the targeted values. For some of the sulfur saturated glasses, the measured concentrations of Al 2 O 3 , Cl - , Cr 2 O 3 , F - , K 2 O, Na 2 O, P 2 O 5 , V 2 O 5 , and ZrO 2 were generally low relative to the targeted values. A comparison of the measured compositions of the quenched and sulfur saturated versions of the study glasses showed that the measured concentrations of Al 2 O 3 , Cl - , and F - were lower for most of the sulfur saturated glasses. The measured Cr 2 O 3 and K 2 O concentrations were markedly lower for the sulfur saturated versions of the glasses as compared to the quenched versions, which may indicate that these elements partitioned to the soluble sulfur salts. A set of modified glasses was received from PNNL later in this study. Chemical analysis showed that these glasses generally met their targeted compositions. The measured SO 3 concentrations were higher for most of the sulfur saturated glasses relative to those of the quenched versions, as expected. Chemical analysis of the wash solutions that resulted from preparation of the sulfur saturated melts identified Cr, K, Na, P, S, and V as the major elements in solution. With the exception of sulfur, this may explain why the measured concentrations of these components in the study glasses were generally below the targeted values. PNNL performed PCTs on quenched and canister centerline cooled (CCC) versions of the study glasses, as well as the modified glasses. The leachates were sent to SRNL for chemical analysis. Minor scatter in the measured values among the triplicate samples for each glass was noted, with significant differences among the triplicate values noted for four of the CCC glasses. Normalized concentration values for some of the study glasses were greater than the 100 g/L maximum (total dissolution), which may indicate an error in the test. It is recommended that PNNL review the performance of the PCTs to determine the cause of these potential outliers and errors. Revision 1 of this report: Corrects an issue with high chromium measurements for the Mod glass compositions and the second set of PCT leachates, Adds data for the Mod glass wash solutions that were unintentionally omitted, Corrects an issue with rounding of the targeted Al 2 O 3 concentrations in the study glasses
12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗