Search NASA⌕ Search

SEARCH · Search NASA

Results for “High spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

THE SOFT X-RAY AND NARROW-LINE EMISSION OF Mrk 573 ON KILOPARSEC SCALES

We present a study of the circumnuclear region of the nearby Seyfert galaxy Mrk 573 using Chandra, XMM-Newton, and Hubble Space Telescope (HST) data. We have studied the morphology of the soft (<2 keV) X-rays comparing it with the [O III] and H{alpha} HST images. The soft X-ray emission is resolved into a complex extended region. The X-ray morphology shows a biconical region extending up to 12 arcsec (4 kpc) in projection from the nucleus. A strong correlation between the X-rays and the highly ionized gas seen in the [O III]{lambda}5007 A image is reported. Moreover, we have studied the line intensities detected with the XMM-Newton Reflection Grating Spectrometer (RGS) and used them to fit the low-resolution EPIC/XMM-Newton and ACIS/Chandra spectra. The RGS/XMM-Newton spectrum is dominated by emission lines of C VI, O VII, O VIII, Fe XVII, and Ne IX, among other highly ionized species. A good fit is obtained using these emission lines found in the RGS/XMM-Newton spectrum as a template for Chandra spectra of the nucleus and extended emission, coincident with the cone-like structures seen in the [O III]/H{alpha} map. The photoionization model Cloudy provides a reasonable fit for both the nuclear region and the cone-like structures showing that the dominant excitation mechanism is photoionization. For the nucleus the emission is modeled using two phases: a high ionization [log (U) = 1.23] and a low ionization [log (U) = 0.13]. For the high-ionization phase the transmitted and reflected components are in a 1:2 ratio, whereas for the low ionization the reflected component dominates. For the extended emission, we successfully reproduced the emission with two phases. The first phase shows a higher ionization parameter for the northwest (log (U) = 0.9) than for the southeast cone (log (U) = 0.3). Moreover, this phase is transmission dominated for the southeast cone and reflection dominated for the northwest cone. The second phase shows a low-ionization parameter (log (U) = -3) and is rather uniform for northwest and southeast cones and equally distributed in reflection and transmission components. In addition, we have also derived the optical/infrared spectral energy distribution (SED) of the nucleus from high spatial resolution images of Mrk 573. The nuclear optical/infrared SED of the nucleus has been modeled by a clumpy torus model. The torus bolometric luminosity agrees very well with the active galactic nucleus (AGN) luminosity inferred from the observed hard X-ray spectrum. The optical depth along the line of sight expected from the torus modeling indicates a high neutral hydrogen column density in agreement with the classification of the nucleus of Mrk 573 as a Compton-thick AGN.

79 ASTRONOMY AND ASTROPHYSICS↗

Monte Carlo simulation of a novel water-equivalent electronic portal imaging device using plastic scintillating fibers

Purpose: Most electronic portal imaging devices (EPIDs) developed so far use a thin Cu plate/phosphor screen to convert x-ray energies into light photons, while maintaining a high spatial resolution. This results in a low x-ray absorption and thus a low quantum efficiency (QE) of approximately 2-4% for megavoltage (MV) x-rays. A significant increase of QE is desirable for applications such as MV cone-beam computed tomography (MV-CBCT). Furthermore, the Cu plate/phosphor screen contains high atomic number (high-Z) materials, resulting in an undesirable over-response to low energy x-rays (due to photoelectric effect) as well as high energy x-rays (due to pair production) when used for dosimetric verification. Our goal is to develop a new MV x-ray detector that has a high QE and uses low-Z materials to overcome the obstacles faced by current MV x-ray imaging technologies. Methods: A new high QE and low-Z EPID is proposed. It consists of a matrix of plastic scintillating fibers embedded in a water-equivalent medium and coupled to an optically sensitive 2D active matrix flat panel imager (AMFPI) for image readout. It differs from the previous approach that uses segmented crystalline scintillators made of higher density and higher atomic number materials to detect MV x-rays. The plastic scintillating fibers are focused toward the x-ray source to avoid image blurring due to oblique incidence of off-axis x-rays. When MV x-rays interact with the scintillating fibers in the detector, scintillation light will be produced. The light photons produced in a fiber core and emitted within the acceptance angle of the fiber will be guided toward the AMFPI by total internal reflection. A Monte Carlo simulation has been used to investigate imaging and dosimetric characteristics of the proposed detector under irradiation of MV x-rays. Results: Properties, such as detection efficiency, modulation transfer function, detective quantum efficiency (DQE), energy dependence of detector response, and water-equivalence of dose response have been investigated. It has been found that the zero frequency DQE of the proposed detector can be up to 37% at 6 MV. The detector, also, is water-equivalent with a relatively uniform response to different energy x-rays as compared to current EPIDs. Conclusions: The results of our simulations show that, using plastic scintillating fibers, it is possible to construct a water-equivalent EPID that has a better energy response and a higher detection efficiency than current flat panel based EPIDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gaussian kernel density functions for compositional quantification in atom probe tomography

Highlights: • A methodology for compositional quantification from atom probe tomography is proposed. • A probability density function p(x) given discrete data points is constructed. • Each atom approximated by a Gaussian function with a particular smoothing parameter. • Density Kernel functions are used to find the optimum smoothing parameter. • The method is validated by using simulated data of semiconductor materials. - Abstract: Atom probe tomography (APT) has the ability to identify the nature and position of single atoms in a material with an almost 3D atomic resolution. However, the quantification of the material composition requires an appropriate treatment of the discrete APT data. When the amount of atoms selected to quantify the composition is relatively small, the spatial resolution is enhanced but the statistical error worsens. Conversely, the increase in the number of atoms considered reduces the spatial resolution, but improving the statistics. We have developed a methodology to reach an optimum equilibrium between the positional and the statistical error in an unsupervised form using Gaussian Kernel density functions. The validity of the method has been tested using APT simulated data of semiconductor materials. It has been proved that the chemical quantification in these materials requires the appropriate selection of the smoothing parameter, obtained without user intervention. In addition, the results have been compared to the usual techniques for composition measurement from APT data (voxelization and proximity histograms), showing better precision for high spatial resolution. This work supplies a data driven methodology based in Gaussian Kernel density functions for the accurate quantification of the composition from APT data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

EBIC spectroscopy - A new approach to microscale characterization of deep levels in semi-insulating GaAs

The microscale characterization of electronic defects in (SI) GaAs has been a challenging issue in connection with materials problems encountered in GaAs IC technology. The main obstacle which limits the applicability of high resolution electron beam methods such as Electron Beam-Induced Current (EBIC) and cathodoluminescence (CL) is the low concentration of free carriers in semiinsulating (SI) GaAs. The present paper provides a new photo-EBIC characterization approach which combines the spectroscopic advantages of optical methods with the high spatial resolution and scanning capability of EBIC. A scanning electron microscope modified for electronic characterization studies is shown schematically. The instrument can operate in the standard SEM mode, in the EBIC modes (including photo-EBIC and thermally stimulated EBIC /TS-EBIC/), and in the cathodo-luminescence (CL) and scanning modes. Attention is given to the use of CL, Photo-EBIC, and TS-EBIC techniques.

Li, C.-J.↗

Application of Remote Sensing to Assess the Impact of Short Term Climate Variability on Coastal Sedimentation

The purpose of this joint University of Wisconsin (UW) and Louisiana State University (LSU) project has been to relate short term climate variation to response in the coastal zone of Louisiana in an attempt to better understand how the coastal zone is shaped by climate variation. Climate variation in this case largely refers to variation in surface wind conditions that affect wave action and water currents in the coastal zone. The primary region of focus was the Atchafalaya Bay and surrounding bays in the central coastal region of Louisiana. Suspended solids in the water column show response to wind systems both in quantity (through resuspension) and in the pattern of dispersement or transport. Wind systems associated with cold fronts are influenced by short term climate variation. Wind energy was used as the primary signature of climate variation in this study because winds are a significant influence on sediment transport in the micro-tidal Gilf of Mexico coastal zone. Using case studies, the project has been able to investigate the influence of short term climate variation on sediment transport. Wind energy data, collected daily for National Weather Service (NWS) stations at Lake Charles and New Orleans, LA, were used as an indicator of short term climate variation influence on seasonal time scales. A goal was to relate wind energy to coastal impact through sediment transport. This goal was partially accomplished by combining remote sensing and wind energy data. Daily high resolution remote sensing observations are needed to monitor the complex coastal zone environment, where winds, tides, and water level all interact to influence sediment transport. The NASA Earth Observing System (EOS) era brings hope for documenting and revealing response of the complex coastal transport mosaic through regular high spatial resolution observations from the Moderate resolution Imaging Spectrometer (MODIS) instrument. MODIS observations were sampled in this project for information content and should continue to be viewed as a resource for coastal zone monitoring. The project initialized the effort to transfer a suspended sediment concentration (SSC) algorithm to the MODIS platform for case 2 waters. MODIS enables monitoring of turbid coastal zones around the globe. The MODIS SSC algorithm requires refinements in the atmospheric aerosol contribution, sun glint influence, and designation of the sediment inherent optical properties (IOPs); the framework for continued development is in place with a plan to release the algorithm to the MODIS direct broadcast community.

Menzel, W. Paul↗

OBSERVATION OF MAGNETIC RECONNECTION DRIVEN BY GRANULAR SCALE ADVECTION

We report the first evidence of magnetic reconnection driven by advection in a rapidly developing large granule using high spatial resolution observations of a small surge event (base size {approx} 4'' Multiplication-Sign 4'') with the 1.6 m aperture New Solar Telescope at the Big Bear Solar Observatory. The observations were carried out in narrowband (0.5 A) He I 10830 A and broadband (10 A) TiO 7057 A. Since He I 10830 A triplet has a very high excitation level and is optically thin, its filtergrams enable us to investigate the surge from the photosphere through the chromosphere into the lower corona. Simultaneous space data from the Atmospheric Imaging Assembly and Helioseismic and Magnetic Imager on board the Solar Dynamics Observatory were used in the analysis. It is shown that the surge is spatio-temporally associated with magnetic flux emergence in the rapidly developing large granule. During the development of the granule, its advecting flow ({approx}2 km s{sup -1}) squeezed the magnetic flux into an intergranular lane area, where a magnetic flux concentration was formed and the neighboring flux with opposite magnetic polarity was canceled. During the cancellation, the surge was produced as absorption in He I 10830 A filtergrams while simultaneous EUV brightening occurred at its base. The observations clearly indicate evidence of a finest-scale reconnection process driven by the granule's motion.

79 ASTRONOMY AND ASTROPHYSICS↗

Heterodyne frequency-domain multispectral diffuse optical tomography of breast cancer in the parallel-plane transmission geometry

Purpose: The authors introduce a state-of-the-art all-optical clinical diffuse optical tomography (DOT) imaging instrument which collects spatially dense, multispectral, frequency-domain breast data in the parallel-plate geometry. Methods: The instrument utilizes a CCD-based heterodyne detection scheme that permits massively parallel detection of diffuse photon density wave amplitude and phase for a large number of source–detector pairs (10{sup 6}). The stand-alone clinical DOT instrument thus offers high spatial resolution with reduced crosstalk between absorption and scattering. Other novel features include a fringe profilometry system for breast boundary segmentation, real-time data normalization, and a patient bed design which permits both axial and sagittal breast measurements. Results: The authors validated the instrument using tissue simulating phantoms with two different chromophore-containing targets and one scattering target. The authors also demonstrated the instrument in a case study breast cancer patient; the reconstructed 3D image of endogenous chromophores and scattering gave tumor localization in agreement with MRI. Conclusions: Imaging with a novel parallel-plate DOT breast imager that employs highly parallel, high-resolution CCD detection in the frequency-domain was demonstrated.

60 APPLIED LIFE SCIENCES↗

Coronary artery wall imaging in mice using osmium tetroxide and micro-computed tomography (micro-CT)

The high spatial resolution of micro-computed tomography (micro-CT) is ideal for 3D imaging of coronary arteries in intact mouse heart specimens. Previously, micro-CT of mouse heart specimens utilized intravascular contrast agents that hardened within the vessel lumen and allowed a vascular cast to be made. However, for mouse coronary artery disease models, it is highly desirable to image coronary artery walls and highlight plaques. For this purpose, we describe an ex vivo contrast-enhanced micro-CT imaging technique based on tissue staining with osmium tetroxide (OsO{sub 4}) solution. As a tissue-staining contrast agent, OsO{sub 4} is retained in the vessel wall and surrounding tissue during the fixation process and cleared from the vessel lumens. Its high X-ray attenuation makes the artery wall visible in CT. Additionally, since OsO{sub 4} preferentially binds to lipids, it highlights lipid deposition in the artery wall. We performed micro-CT of heart specimens of 5- to 25-week-old C57BL/6 wild-type mice and 5- to 13-week-old apolipoprotein E knockout (apoE{sup -/-}) mice at 10 {mu}m resolution. The results show that walls of coronary arteries as small as 45 {mu}m in diameter are visible using a table-top micro-CT scanner. Similar image clarity was achieved with 1/2000th the scan time using a synchrotron CT scanner. In 13-week-old apoE mice, lipid-rich plaques are visible in the aorta. Our study shows that the combination of OsO{sub 4} and micro-CT permits the visualization of the coronary artery wall in intact mouse hearts.

59 BASIC BIOLOGICAL SCIENCES↗

Advances in Spectro‐Microscopy Methods and their Applications in the Characterization of Perovskite Materials

Perovskite materials are promising contenders as the active layer in light-harvesting and light-emitting applications if their long-term stability can be sufficiently increased. Chemical and structural engineering are shown to enhance long-term stability, but the increased complexity of the material system also leads to inhomogeneous functional properties across various length scales. Thus, scanning probe and high-resolution microscopy characterization techniques are needed to reveal the role of local defects and the results promise to act as the foundation for future device improvements. Here, a look at the parameter space: technique-specific sample penetration depth versus probe size highlights a gap in current methods. High spatial resolution combined with a deep penetration depth is not yet achievable. However, multimodal measurement technique may be the key to covering this parameter space. In this perspective, current advanced spectro-microscopy methods which have been applied to perovskite materials are highlighted.

Luo, Yanqi↗

Research relative to high resolution camera on the advanced X-ray astrophysics facility

The HRC (High Resolution Camera) is a photon counting instrument to be flown on the Advanced X-Ray Astrophysics Facility (AXAF). It is a large field of view, high angular resolution, detector for the x-ray telescope. The HRC consists of a CsI coated microchannel plate (MCP) acting as a soft x-ray photocathode, followed by a second MCP for high electronic gain. The MCPs are readout by a crossed grid of resistively coupled wires to provide high spatial resolution along with timing and pulse height data. The instrument will be used in two modes, as a direct imaging detector with a limiting sensitivity of 10 to the -15 ergs sq cm sec in a 10 to the 5th second exposure, and as a readout for an objective transmission grating providing spectral resolution of several hundreds to thousands.

Source record↗

Portable high speed photometry systems for observing occultations

Ring orbit studies for Uranus have been particularly fruitful because of the ability, through occultations, to obtain data of high spatial resolution at the rate of 1 to 2 times per year. The occultation program at M.I.T. involves: (1) identifying the scientific questions that can be answered by occultation events, (2) predicting the zone of visibility for the useful events, (3) maintaining and improving a set of portable high-speed photometric systems, (4) obtaining the observations, and (5) reducing the data and interpreting the results. Two stellar occultations by Uranus occurred in May 1985, and were observed with a network of large telescopes that encompassed the Northern and Southern Hemispheres. Portable quartz-oscillator time standards were used at all observatories, and were calibrated before and after each event. Observations obtained form Cerro Tololo and McDonald Observatories of the 4 May and 24 May 1985 occultations by the Uranian rings clearly show a companion to the delta ring on both the immersion and emersion traces. The occultation by Ceres that occurred on 12 November 1984 was observed. Preliminary results give a mean diameter of 933 + or - 10 km, which implies a geometric albedo, Pv = 0.07 + or - 0.01 and a density 2.7 + or - 0.3 gm cu/cm. Hence Ceres is likely composed of silicate material throughout.

Elliot, J. L.↗

The Advanced X-ray Astrophysics Facility high resolution camera

The HRC (High Resolution Camera) is a photon counting instrument to be flown on the Advanced X-Ray Astrophysics Facility (AXAF). It is a large field of view, high angular resolution, detector for the X-ray telescope. The HRC consists of a CsI coated microchannel plate (MCP) acting as a soft X-ray photocathode, followed by a second MCP for high electronic gain. The MCPs are readout by a crossed grid of resistively coupled wires to provide high spatial resolution along with timing and pulse height data. The instrument will be used in two modes, as a direct imaging detector with a limiting sensitivity of 10 to the -15th ergs/sq cm sec in a 10 to the 5th second exposure, and as a readout for an objective transmission grating providing spectral resolution of several hundreds to thousands.

Murray, Stephen S.↗

Laser Doppler Velocimetry and full-field soot volume fraction

Since its introduction in the mid-sixties, Laser Doppler Velocimetry (LDV) has become one of the most widely used methods for the measurement of flows. Its remote and essentially non-intrusive nature provides an invaluable tool for a variety of difficult measurement situations which would be otherwise inaccessible. The high spatial resolution and rapid temporal response afforded by this technique are well suited to the determination of spatial and temporal details of flow fields, as well as characterization of turbulence. Advances in the understanding of the properties of LDV signals, accompanied by technological advances in coherent laser sources, detectors of high sensitivity and low noise, optical fabrication techniques and high-speed digital signal processing architectures have resulted in systems of increased accuracy and flexibility. As will be shown, recent progress in solid-state lasers and photo-detectors has been beneficial insofar as the compatibility of this method with the unique and severe constraints inherent in microgravity combustion science experiments.

Greenberg, Paul S.↗

The Stellar Content of H72.97-69.39, a Potential Super Star Cluster in the Making

Young massive clusters and super star clusters (SSCs) represent an extreme mode of star formation. Far-infrared imaging of the Magellanic Clouds has identified one potential embedded SSC, HSO BMHERICC J72.971176-69.391112 (H72.97-69.39 in short), in the southwest outskirts of the Large Magellanic Cloud. We present Gemini Flamingos 2 and GSAOI near-infrared imaging of a 3′ × 3′ region around H72.97-69.39 in order to characterize the stellar content of the cluster. The stellar content is probed down to 1.5 M {sub ⊙}. We find substantial dust extinction across the cluster region, extending up to A {sub K} of 3. Deeply embedded stars are associated with ALMA-detected molecular gas suggesting that star formation is ongoing. The high spatial resolution of the GSAOI data allows identification of the central massive object associated with the {sup 13}CO ALMA observations and detection of fainter low-mass stars around the H30α ALMA source. The morphology of the molecular gas and the nebulosity from adjacent star formation suggest they have interacted covering a region of several parsecs. The total stellar content in the cluster is estimated from the intermediate- and high-mass stellar content to be at least 10,000 M {sub ⊙}, less than R136 with up to 100,000 M {sub ⊙} within 4.7 pc radius, but places it in the regime of an SSC. Based on the extinction determination of individual stars we estimate a molecular gas mass in the vicinity of H72.97-69.39 of 6600 M {sub ⊙}, suggesting more star formation can be expected.

74 ATOMIC AND MOLECULAR PHYSICS↗

Magnetic domains and domain wall pinning in atomically thin CrBr 3 revealed by nanoscale imaging

The emergence of atomically thin van der Waals magnets provides a new platform for the studies of two-dimensional magnetism and its applications. However, the widely used measurement methods in recent studies cannot provide quantitative information of the magnetization nor achieve nanoscale spatial resolution. These capabilities are essential to explore the rich properties of magnetic domains and spin textures. Here, we employ cryogenic scanning magnetometry using a single-electron spin of a nitrogen-vacancy center in a diamond probe to unambiguously prove the existence of magnetic domains and study their dynamics in atomically thin CrBr 3 . By controlling the magnetic domain evolution as a function of magnetic field, we find that the pinning effect is a dominant coercivity mechanism and determine the magnetization of a CrBr 3 bilayer to be about 26 Bohr magnetons per square nanometer. The high spatial resolution of this technique enables imaging of magnetic domains and allows to locate the sites of defects that pin the domain walls and nucleate the reverse domains. Our work highlights scanning nitrogen-vacancy center magnetometry as a quantitative probe to explore nanoscale features in two-dimensional magnets.

36 MATERIALS SCIENCE↗

Fibreoptic fluorescent microscopy in studying biological objects

The method of fluorescent microscopy is developed based on employment of a single-mode fibreoptic channel to provide high spatial resolution 3D images of large cleared biological specimens using the 488-nm excitation laser line. The transverse and axial resolution of the setup is 5 and 13 {mu}m, respectively. The transversal sample size under investigation is up to 10 mm. The in-depth scanning range depends on the sample transparency and reaches 4 mm in the experiment. The 3D images of whole mouse organs (heart, lungs, brain) and mouse embryos obtained using autofluorescence or fluorescence of exogenous markers demonstrate a high contrast and cellular-level resolution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of rodded BWR assembly pin powers with simulate

In the development of Studsvik's nodal code SIMULATE5, special attention has been given to the accurate description of pin powers. The code solves the multi-group diffusion or simplified P3 equations with high spatial resolution. A short description is given of the handling of material heterogeneities in the axial and radial directions - the axial re-homogenization and the radial sub-mesh model, respectively. Furthermore, two models which are of special importance in the presence of control rods, and hence on the pellet clad interaction (PCI) phenomenon, are described; the quarter-assembly thermal-hydraulic treatment and the depletion of absorber material. A numerical example for a real core shows that while the impact of the fine grained description is negligible on global parameters such as k{sub eff}, the effect on pin powers may be substantial. For a deeply inserted and highly depleted control rod, the difference in pin powers caused by neglecting the advanced models of SIMULATE5, may be as high as 15 %. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗