At least 973 records · Page 54

First experiments with Cs doped Mo as surface converter for negative hydrogen ion sources

A study was conducted on the properties of molybdenum implanted with caesium as an approach to reduce the Cs consumption of negative hydrogen ion sources based on evaporated Cs. The depth profiles of the implanted Cs were simulated by SDTrimSP and experimentally determined by X-ray photoelectron spectroscopy depth profiling. In particular, one year after implantation, the depth profiles showed no signs of Cs diffusion into the molybdenum, suggesting long term stability of the implanted Cs atoms. The H{sup −} surface generation mechanisms on the implanted samples in hydrogen plasma were investigated, and the stability of the H{sup −} yield during four hours low power hydrogen plasma discharges was demonstrated. An estimation of the work function reduction (−0.8 eV) by the Cs implantation was performed, and a comparison of the relative negative ion yields between the implanted samples and highly oriented pyrolitic graphite showed that the Cs doped Mo negative ion yield was larger.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Arc plasma generator of atomic driver for steady-state negative ion source

The paper reviews the results of development of steady-state arc-discharge plasma generator with directly heated LaB{sub 6} cathode. This arc-discharge plasma generator produces a plasma jet which is to be converted into an atomic one after recombination on a metallic plate. The plate is electrically biased relative to the plasma in order to control the atom energies. Such an intensive jet of hydrogen atoms can be used in negative ion sources for effective production of negative ions on a cesiated surface of plasma grid. All elements of the plasma generator have an augmented water cooling to operate in long pulse mode or in steady state. The thermo-mechanical stresses and deformations of the most critical elements of the plasma generator were determined by simulations. Magnetic field inside the discharge chamber was optimized to reduce the local power loads. The first tests of the steady-state arc plasma generator prototype have performed in long-pulse mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling of a negative ion source. III. Two-dimensional structure of the extraction region

The self-consistent production and transport of H{sup -} in the extraction region of a hybrid negative ion source is modeled by means of a two-dimensional particle-in-cell/Monte Carlo simulation. The normal coordinate and one parallel coordinate with respect to the plasma grid are considered to analyze the transport of negative ions. Results show that, in order to establish space charge compensation, the extraction of surface-produced negative ions is limited by the flux of positive ions directed toward the plasma grid surface. An electrostatic barrier appears just in front of the wall, reflecting the majority of surface-produced H{sup -} and reducing by this their extraction probability to only 8.5%. Results reproduce the experimentally observed influence of the plasma grid bias voltage on the extraction identifying as a key element the presence of a saddle point in the electric potential distribution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Deposition and characterization of zirconium nitride (ZrN) thin films by reactive magnetron sputtering with linear gas ion source and bias voltage

Zirconium nitride thin films have been prepared on stainless steel substrate (304L grade) by reactive cylindrical magnetron sputtering method with Gas Ion Source (GIS) and bias voltage using optimized coating parameters. The structure and surface morphologies of the ZrN films were characterized using X-ray diffraction, atomic microscopy and scanning electron microscopy. The adhesion property of ZrN thin film has been increased due to the GIS. The coating exhibits better adhesion strength up to 10 N whereas the ZrN thin film with bias voltage exhibits adhesion up to 500 mN.

36 MATERIALS SCIENCE↗

Tests of Cs-Free Operation of the SNS RF H⁻ Ion Sources

Tests were performed at SNS in collaboration with visiting colleagues from ISIS, UK to evaluate the uncesiated beam performance of the SNS RF H⁻ ion sources. Two spare experimental sources, one with internal antenna and one with external antenna were used for the tests. The beam currents achieved with Cs-free operations accounted for about 1/3 to 1/2 of the beam currents produced with cesiated operations. ~17 mA uncesiated H⁻ current was demonstrated within the tested RF power range up to 65 kW with the internal antenna source and ~15 mA with up to 40 kW RF with the external antenna source. In Cs-free operations, the power supply for the electron dumping electrode was loaded down below its set voltage but was not too drastic to tamper the operation.

Han, Baoxi↗

Improved magnetron cold-cathode ion source

Cold cathode ionization source generates smaller amounts of spurious gases and has a higher sensitivity than commonly used hot-filament ion sources. Photon and X-ray background noise are reduced below detectable levels.

Roehrig, J.↗

Isotope ratio characteristics and sensitivity for uranium determinations using a liquid sampling-atmospheric pressure glow discharge ion source coupled to an Orbitrap mass analyzer

Abstract The continued development of the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma as an ion source for diverse, elemental/isotopic analysis applications continues. To this end, characterization of the capabilities in performing precise and accurate isotope ratio (IR) determinations is essential. Based on past experience with the Thermo Exactive Orbitrap mass analyzer, the LS-APGD was interfaced with this instrument for these tests. While the Orbitrap platform has demonstrated excellent mass resolution and accuracy in “organic” mass spectrometry (MS) applications, work using an Orbitrap for IR analysis is very sparse. These efforts build off previous work in this coupling, where the importance of a few of the LS-APGD discharge parameters and Orbitrap data acquisition methods on IR precision and accuracy were probed. Presented here are the results of a study that evaluated the analytical precision for natural uranium sample (assumed 235U/238U = 0.0072) determinations. The instrumental parameters evaluated include the number of microscans and scans making up a data acquisition set, uranium concentration/signal level, sample make-up, and Fourier transform digitization window. Ultimately, a precision of 0.41% relative standard deviation (RSD) can be achieved for a single determination, with a reproducibility of 1.63 %RSD over 10 separate analytical measurements. A preliminary study of matrix effects on IR measurements of U is presented, highlighting the importance of pre-mass selection before injection into the Orbitrap. The analytical system sensitivity is suggested with the ability to produce a calibration function having an R2 value of >0.99 over a range of 4 orders of magnitude of concentration (~1 – 1000 ng mL-1). These efforts demonstrate the very promising pairing of the LS-APGD ionization source and the Orbitrap, pointing as well to definitive paths forward to better utilize both components in high quality isotope ratio mass spectrometry (IRMS).

Environmental Molecular Sciences Laboratory↗

Effects of external magnetic filter on behaviors of fast primary electrons in a volume negative ion source

The relationship between enhancement of hydrogen negative ion H{sup -}, volume production, and behaviors of fast primary electrons is studied theoretically. Trajectories of fast primary electrons are calculated, including collisional effects with hydrogen molecules. Active region of fast electrons depends strongly on the field intensity of the magnetic filter (MF), B{sub MF}, and filament position. Therefore, spatial distributions of ionization and vibrational excitation collision points are also affected with changing B{sub MF}. Although number of vibrational excitation collision points is much smaller than that of ionization collision points due to different mean free path, the relative intensity is varied by changing energy of fast electrons. According to the results and discussions including transport of produced vibrationally excited molecules, for enhancement of H{sup -} production, it is desired that fast electrons should approach the MF position and move into the downstream region as deep as possible without destruction of H{sup -} ions. To realize these conditions, good combination between filament position and the intensity of the MF should be required.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of fast positive ions incident on caesiated plasma grid of negative ion source

This paper describes the effect on negative ion formation on a caesiated surface of the backscattering of positive ions approaching it with energy of a few tens of eV. For a positive ion energy of 45 eV, the surface produced negative ion current density due to these fast positive ions is 12 times larger than that due to thermal atoms, thus dominating the negative ion surface production instead of the thermal atoms, as considered until now.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A double-layer based model of ion confinement in electron cyclotron resonance ion source

The paper proposes a new model of ion confinement in ECRIS, which can be easily generalized to any magnetic configuration characterized by closed magnetic surfaces. Traditionally, ion confinement in B-min configurations is ascribed to a negative potential dip due to superhot electrons, adiabatically confined by the magneto-static field. However, kinetic simulations including RF heating affected by cavity modes structures indicate that high energy electrons populate just a thin slab overlapping the ECR layer, while their density drops down of more than one order of magnitude outside. Ions, instead, diffuse across the electron layer due to their high collisionality. This is the proper physical condition to establish a double-layer (DL) configuration which self-consistently originates a potential barrier; this “barrier” confines the ions inside the plasma core surrounded by the ECR surface. The paper will describe a simplified ion confinement model based on plasma density non-homogeneity and DL formation.

43 PARTICLE ACCELERATORS↗

Plasma asymmetry due to the magnetic filter in fusion-type negative ion sources: Comparisons between two and three-dimensional particle-in-cell simulations

Previously reported 2D Particle-In-Cell Monte Carlo Collisions (PIC-MCC) simulations of negative ion sources under conditions similar to those of the ITER neutral beam injection system have shown that the presence of the magnetic filter tends to generate asymmetry in the plasma properties in the extraction region. In this paper, we show that these conclusions are confirmed by 3D PIC-MCC simulations and we provide quantitative comparisons between the 2D and 3D model predictions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cooling Design and Thermal Analysis for Thermal Shields of a Cryocooler-Cooled Superconducting ECR Ion Source MARS-D Magnet

Here, a demonstrative NbTi based Mixed Axial and Radial field System (MARS-D) is being developed for a next-Generation Electron Cyclotron Resonance Ion Source (ECRIS) at Lawrence Berkeley National Laboratory (LBL), which employs a novel closed-loop coil design scheme that more efficiently utilizes conductor fields and extend the application of NbTi for high frequency (up to 45 GHz) ECR operation. The NbTi MARS-D magnet consists of a single hexagonally shaped closed-loop coil and a set of auxiliary solenoids. A cryostat for cooling the MARS-D magnet is under design at LBL. The MARS-D magnet working around 4.2 K will be bath-cooled in liquid helium using multiple two-stage cryocoolers. An intermediate temperature thermal radiation shield is adopted to reduce the heat leakage imposed on 4.2 K coil cold mass from room temperature. The thermal shield is conduction-cooled by the first-stage cold heads of four two-stage cryocoolers and the cold head of a single-stage cryocooler shared with nine binary leads. The temperature in the area of the shield that warm ends of HTS leads are mounted on is expected no higher than 60 K, which is limited by maximum allowable working temperature of HTS leads. The paper presents thermal analysis on the thermal radiation shield including heat loads and effects of eddy current induced during quench on its material selection.

ECRIS↗

Simulation and beamline experiments for the superconducting electron cyclotron resonance ion source VENUS

The particle-in-cell code WARP has been enhanced to incorporate both two- and three-dimensional sheath extraction models giving WARP the capability of simulating entire ion beam transport systems including the extraction of beams from plasma sources. In this article, we describe a method of producing initial ion distributions for plasma extraction simulations in electron cyclotron resonance (ECR) ion sources based on experimentally measured sputtering on the source biased disk. Using this initialization method, we present preliminary results for extraction and transport simulations of an oxygen beam and compare them with experimental beam imaging on a quartz viewing plate for the superconducting ECR ion source VENUS.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Operation of an Electron-Bombardment Ion Source with Various Gases

The efficiency of the electron-bombardment thrustor is approaching the maximum that can be expected. Desired lifetimes (of the order of 10,000 hr) have not yet been reached, but present knowledge indicates such lifetimes should be obtainable, The simplicity of this thrustor makes it interesting as an ion source for various laboratory experiments. Various gases have been used to determine the ion-chamber and accelerator performance for such applications.

Reader, Paul D.↗