Microstructural evolution of P92 ferritic/martensitic steel under argon ion irradiation

Microstructural evolution of P92 ferritic/martensitic steel irradiated by Ar{sup +} ion beams at doses from 0.6 to 230 displacements per atom (dpa) at room temperature was investigated with conventional transmission electron microscope technique. Selected-area electron diffraction combined with bright-field and dark-field contrast image indicated that carbide/matrix interfaces were more easily damaged. The carbide peripheries became partly amorphous at irradiation dose of 2.3 dpa and were almost complete amorphous at the dose of 11.5 dpa. The small carbides would re-precipitate in matrices at 34.5 dpa. Energy dispersive X-ray analysis revealed that segregation of Cr and W and depletion of Fe in carbides occurred under irradiation. With the irradiation dose increasing, the irradiation induced segregation and depletion became more severe, which would influence mechanical properties of the steel. - Research Highlights: {yields} Carbide/matrix interfaces in P92 ferritic/martensitic steel were easily damaged. {yields} Small carbides re-precipitated in matrices after higher dose irradiation. {yields} Segregation of Cr and W and depletion of Fe in carbides occurred after irradiation.

36 MATERIALS SCIENCE↗

Surface composition, microstructure and corrosion resistance of AZ31 magnesium alloy irradiated by high-intensity pulsed ion beam

High-intensity pulsed ion beam (HIPIB) irradiation of AZ31 magnesium alloy is performed and electrochemical corrosion experiment of irradiated samples is carried out by using potentiodynamic polarization technology in order to explore the effect of HIPIB irradiation on corrosion resistance of magnesium alloy. The surface composition, cross-sectional morphology and microstructure are characterized by using electron probe microanalyzer, optical microscope and transmission electron microscope, respectively. The results indicated that HIPIB irradiation leads to a significant improvement in corrosion resistance of magnesium alloy, in terms of the considerable increase in both corrosion potential and pitting breakdown potential. The microstructural refinement and surface purification induced by HIPIB irradiation are responsible for the improved corrosion resistance. - Research Highlights: {yields} A modified layer about 30 {mu}m thick is obtained by HIPIB irradiation. {yields} Selective ablation of element/impurity phase having lower melting point is observed. {yields} More importantly, microstructural refinement occurred on the irradiated surface. {yields} The modified layer exhibited a significantly improved corrosion resistance. {yields} Improved corrosion resistance is ascribed to the combined effect induced by HIPIB.

36 MATERIALS SCIENCE↗

A mechanism-based quantitative multi-scale framework for investigating irradiation hardening of tungsten at low temperature

We present the development and validation of a mechanism-based multi-scale modeling framework to quantitatively link the irradiation defect evolution kinetics at the microscopic scale to the macroscopic yield strength and flow stress evolution of tungsten irradiated at low temperature (0.08 < T/T m < 0.18, where T m is the melting point and is equal to 3673 K). The mechanism-based strength model, proposed as the superposition of thermal softening and modified dispersed barrier hardening, is developed to understand the underlying strengthening mechanisms. The thermal softening exponent as defined in the Johnson-Cook model is obtained by fitting unirradiated yield strength at different temperatures. A set of irradiation-induced defect kinetics equations with the thermodynamics parameters derived from the atomic calculations reported in the literature is used to determine the densities and sizes of defect clusters at the meso-scale, and the predicted irradiation damage characteristics are in reasonable quantitative agreement with experimental data from literature. The effects of irradiation condition (temperature and irradiation dose) and test temperature on yield strength are quantitatively predicted and compared with experimental measurements from the literature. Here, the predicted irradiation hardening and strain hardening are compared with experimental data as model validation.

36 MATERIALS SCIENCE↗

Method for analyzing passive silicon carbide thermometry with a continuous dilatometer to determine irradiation temperature

Silicon carbide is used as a passive post-irradiation temperature monitor because the irradiation defects will anneal out above the irradiation temperature. The irradiation temperature is determined by measuring a property change after isochronal annealing, i.e., lattice spacing, dimensions, electrical resistivity, thermal diffusivity, or bulk density. However, such methods are time-consuming since the steps involved must be performed in a serial manner. This work presents the use of thermal expansion from continuous dilatometry to calculate the SiC irradiation temperature, which is an automated process requiring minimal setup time. Analysis software was written that performs the calculations to obtain the irradiation temperature and removes possible user-introduced error while standardizing the analysis. In addition, this method has been compared to an electrical resistivity and isochronal annealing investigation, and the results revealed agreement of the calculated temperatures. These results show that dilatometry is a reliable and less time-intensive process for determining irradiation temperature from passive SiC thermometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of the continuous dilatometer method of silicon carbide thermometry for passive irradiation temperature determination

Silicon carbide (SiC) is a primary candidate for passive irradiation temperature monitoring, and continuous dilatometry (CD) has been proposed as the key method for extracting irradiation temperatures from SiC thermometry samples. The CD method was evaluated to determine the sensitivity of the technique to the analysis procedure, as well as its accuracy and precision. Analysis found that the CD method had a ±20 °C sensitivity to the algorithm used to determine the irradiation temperatures. Comparison of the CD method with the continuous length change method for SiC thermometry showed CD is a more viable method of extracting irradiation temperatures. In conclusion, a comparison of irradiation temperatures determined by CD with those from active thermocouple measurements further validated the CD method for accurately and precisely determining irradiation temperatures in materials test reactor irradiations.

36 MATERIALS SCIENCE↗

Experiment design for the neutron irradiation of $\mathrm{PM-HIP}$ alloys for nuclear reactors

Here, this article describes the design of an Advanced Test Reactor (ATR) drop-in neutron irradiation experiment aiming to directly compare the performance of nuclear structural alloys fabricated by powder metallurgy with hot isostatic pressing (PM-HIP) against conventional casting or forging. There is growing interest in PM-HIP alloys for nuclear applications because of their microstructural uniformity, superior mechanical properties, and reduced dependence on welding and machining, compared to cast/forged alloys. Nuclear code-qualification of PM-HIP alloys requires neutron irradiation testing to demonstrate performance under relevant conditions. In this experiment, six nuclear structural alloys were irradiated: Ni-based alloys 625 and 690, Grade 91 ferritic steel, SA508 pressure vessel steel, and 304L and 316L austenitic stainless steels. The experiment is assembled into seven capsules in four test trains and irradiated in three ATR inboard A positions. Both the PM-HIP and cast/forged versions of each alloy were irradiated under nearly identical conditions for comparative purposes, to target doses of 1 ± 0.2 and 3 ± 0.2 dpa at temperatures of 300 ± 50 °C and 400 ± 50 °C. A thorough description of the experiment design and thermal, structural and neutronic analyses performed to ensure the targeted irradiation conditions are met is provided. Specimens were configured as small disks, compact tension specimens and tensile bars to facilitate post-irradiation examination (PIE) that will include mechanical testing, microstructure characterization, and fracture toughness testing. Given the considerations for ASTM standardized mechanical testing, comparative fluence and temperature across specimen pairs, and comprehensive PIE planning herein, this work serves as a template for future nuclear materials qualification experiment designs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaluation of clear-sky and satellite-derived irradiance data for determining the degradation of photovoltaic system performance

Knowing the degradation in performance of a photovoltaic (PV) system over time is important for estimating the lifetime energy produced and the financial return. A key parameter for normalizing performance and determining degradation is the plane-of-array (POA) irradiance. Because accurate long-term POA measurements are not always readily available, three methods of providing irradiance data for determining the degradation rate of PV systems were evaluated—a method using irradiance data modeled with the Ineichen clear-sky model and monthly Linke turbidity coefficients, a method using the supplemental clear-sky irradiance data from the National Solar Radiation Data Base (NSRDB), and a method using the NSRDB solar irradiance data for both cloudy and clear-sky conditions (all-sky). The irradiance data from the three methods were evaluated using measured irradiance data from 1998 through 2018 for the seven-station SURFRAD network and for 3-, 5-, and 10-year periods that might be used for evaluating PV system performance. Only the two clear-sky methods for the 10-year periods had less uncertainty with respect to determining PV system degradation than the expected median degradation rate for PV systems of -0.5%/year to -0.6%/year. Shorter periods and the all-sky method had larger uncertainties, making their use questionable for determining the degradation rates of PV systems.

14 SOLAR ENERGY↗

Morphological study of borosilicate glass surface irradiated by heavy ions

Borosilicate glass is a candidate material for radiation waste formation and other optical applications in various fields. To understand the radiation effect of borosilicate glass, heavy ion (Ar q+ , Kr q+ and Xe q+ ) irradiations were used to simulate the alpha and recoiled nuclei irradiations in this study. The surface morphology of glass has been compared to ion irradiation doses and ion energies. The surface topography evolution of irradiated samples is characterized by optical microscopy, atomic force microscopy (AFM), transmission electron microscopy (TEM) and secondary ion mass spectrometry (SIMS). Micro-bumps are observed on the sample surface after irradiationwith 5 MeV Xe q+ over 5 × 10 13 ions·cm -2 . The size and density of the bumps increaseswith increasing irradiation dose. At a lowdose, bumps are on the nanometer (nm) scale and rather rare.While the dose is higher than 9 × 10 15 ions·cm -2 , the size of bumps is on the scale of a few microns, and the density is saturated. However, the height of the bumps increases froma fewnmto over 150nmwith further irradiation. The distribution of micro-bumps is nearly homogeneous. The bumps are condensed and swell up, and there is no crystallized structure according to the TEMdiffraction pattern. Elementmigration and concentrations are observedwith SIMS imaging. The arrayed micro-bumps are a new finding, and they might be used to change the surface properties. Bump formation is caused by phase separation, and volume swelling is induced by ion irradiation.

36 MATERIALS SCIENCE↗

Interinstitutional Study of the New EURO-GANEX Process Resistance by Gamma Irradiation Test Loops

As part of the homogeneous actinides recycling strategy, the EURO-GANEX process is one of the most promising options to achieve the goal of minor actinides recovery. However, EURO-GANEX also has various drawbacks that are being addressed. Improvements made to EURO-GANEX system have resulted in the emergence of the so-called New EURO-GANEX process, where the composition of the solvent has been modified by replacing TODGA and DMDOHEMA with cis-mTDDGA in the organic phase and SO3-Ph-BTP with PyTri-Diol in the aqueous phase in order to resolve important issues. The objective of this work is twofold: evaluate the gamma radiolysis resistance of the new EURO-GANEX process by dynamic irradiation conditions simulating the three main steps of the process and validate the design of CIEMAT Náyade, CEA Marcel and INL irradiation loop devices since each of them mimics different aspects of the real process. Náyade and the INL loops could irradiate together the organic and aqueous phases, whereas in the CEA loop, the irradiated solvent is recycled continuously inside a platform with several stages of mixer-settlers containing aqueous flows simulating the three main steps of the process. The extraction performances and changes in the composition of the solvent have been analysed during the irradiation experiment by different techniques: gamma spectrometry and ICP-MS/OES for cations or tracers extraction, and HPLC-MS to quantify the degradation and evaluate the degradation compounds. Additionally, in spite of some differences between the three-irradiation facilities, this inter-institutional study shows that they are three comparative tools, which provide results on the stability towards radiolysis of a liquid-liquid extraction system. Favourable extraction results for the different steps are obtained according to the static irradiation studies found in literature. However, the degradation of cis-mTDDGA is appreciable leading to degradation compounds, some of which form precipitates and produce important changes in viscosity, important aspects that must be addressed prior to the successful industrial application of the new EURO-GANEX process.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Surface Modification of Polymer Substrates by Oxygen Ion Irradiation

Oxygen cluster ions and/or monomer ions were used for the sputtering and the surface modification of polymers such as polycarbonate (PC) and polyethylene terephthalate (PET). For the case of oxygen cluster ion irradiation, the sputtered depth increased with increase of the acceleration voltage, and the sputtering yield was much larger than that by the monomer ion irradiation. The sputtered particles represented the polymer structure, which indicated that the bond scission by the cluster ion irradiation resulted in an ejection of monomer molecule through the intermolecular collision. On the other hand, for the oxygen monomer ion irradiation, the implanted depth increased with increase of the acceleration voltage, and the bond scission occurred at the deep region through the binary collision with the high energetic ions. Therefore, the sputtering yield for the polymer surfaces decreased, and the sputtering effect became very small. Furthermore, the simultaneous use of oxygen cluster and monomer ions was more effective for oxidation of the PET surfaces rather than the monomer ion irradiation or the cluster ion irradiation. As a result, the contact angle measurement showed that the wettability of the PET surfaces irradiated by the simultaneous use of oxygen cluster and monomer ions was much enhanced.

36 MATERIALS SCIENCE↗

Investigation of Damage with Cluster Ion Beam Irradiation Using HR-RBS

Cluster ion beam can process targets with shallow damage because of the very low irradiation energy per atom. However, it is needed to investigate the damage with cluster ion beam irradiation, because recent applications demand process targets with ultra low damage. The shallow damage can be investigated from depth profiles of specific species before and after ion irradiation. They can be measured with secondary ion mass spectrometry (SIMS) and Rutherford backscattering spectroscopy (RBS). High resolution Rutherford backscattering spectroscopy (HR-RBS) is a non destructive measurement method and depth profiles can be measured with nano-resolution. The cluster ion beam mixing of thin Ni layer in carbon targets can be investigated with HR-RBS. The mixing depth with cluster ion irradiation at 10 keV was about 10 nm. The mixing depth with cluster ion irradiation at 1 keV and 5 keV were less than 1 nm and 5 nm, respectively. The number of displaced Ni atoms with cluster ion irradiation was very larger than that with monomer ion irradiation of same energy. This result shows that violent mixing occurs with single cluster impact.

74 ATOMIC AND MOLECULAR PHYSICS↗

A nanotube based electron microbeam cellular irradiator for radiobiology research

A prototype cellular irradiator utilizing a carbon nanotube (CNT) based field emission electron source has been developed for microscopic image-guided cellular region irradiation. The CNT cellular irradiation system has shown great potential to be a high temporal and spatial resolution research tool to enable researchers to gain a better understanding of the intricate cellular and intercellular microprocesses occurring following radiation deposition, which is essential to improving radiotherapy cancer treatment outcomes. In this paper, initial results of the system development are reported. The relationship between field emission current, the dose rate, and the dose distribution has been investigated. A beam size of 23 {mu}m has been achieved with variable dose rates of 1-100 Gy/s, and the system dosimetry has been measured using a radiochromic film. Cell irradiation has been demonstrated by the visualization of H2AX phosphorylation at DNA double-strand break sites following irradiation in a rat fibroblast cell monolayer. The prototype single beam cellular irradiator is a preliminary step to a multipixel cell irradiator that is under development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structural Changes Induced by Low-Flux Ion Irradiation in a Ni{sub 4}Mo Alloy

Irradiation induced random displacements of atoms and replacement collision sequences are possible mechanisms for phase transformations as well as other physical properties changes as grain size variation and hardness increase or decrease. In this study Ni{sub 4}Mo alloy samples were subject to low-flux bombardment by ion beams. This alloy has similar structure to the Hastelloy-C used in industry and to U{sub 3}Si that is used as nuclear fuel. Sample regions were irradiated while the energy density of the bombarding beams was carefully controlled and the non-irradiated regions were kept close to room temperature. This way the irradiation induced temperature increase was highly localized creating ''quench-like'' conditions. After the irradiation, the samples were annealed at low temperature. Due to irradiation conditions there was a high density of nucleation sites favoring the formation of finer grain structures as well as localized phase transformations. The results showed that with the appropriate fluence and post-irradiation treatment, a coarse grained specimen can be forced to re-crystallize with a smaller grain size and manifest a specific change in hardening values due mainly to an order-disorder transformation [1,2].

36 MATERIALS SCIENCE↗

Tuneable magnetic patterning of paramagnetic Fe{sub 60}Al{sub 40} (at. %) by consecutive ion irradiation through pre-lithographed shadow masks

Arrays of ferromagnetic circular dots (with diameters ranging from 225 to 420 nm) have been prepared at the surface of atomically ordered paramagnetic Fe{sub 60}Al{sub 40} (at. %) sheets by means of ion irradiation through prelithographed poly(methyl methacrylate) (PMMA) masks. The cumulative effects of consecutive ion irradiation (using Ar{sup +} ions at 1.2 x 10{sup 14} ions/cm{sup 2} with 10, 13, 16, 19 and 22 keV incident energies) on the properties of the patterned dots have been investigated. A progressive increase in the overall magneto-optical Kerr signal is observed for increasingly larger irradiation energies, an effect which is ascribed to accumulation of atomic disorder. Conversely, the coercivity, H{sub C}, shows a maximum after irradiating at 16-19 keV and it decreases for larger irradiation energies. Such a decrease in H{sub C} is ascribed to the formation of vortex states during magnetization reversal, in agreement with results obtained from micromagnetic simulations. At the same time, the PMMA layer, with an initial thickness of 90 nm, becomes progressively thinned during the successive irradiation processes. After irradiation at 22 keV, the remaining PMMA layer is too thin to stop the incoming ions and, consequently, ferromagnetism starts to be generated underneath the nominally masked areas. These experimental results are in agreement with calculations using the Monte-Carlo simulation Stopping Range of Ions in Matter software, which show that for exceedingly thin PMMA layers Ar{sup +} ions can reach the Fe{sub 60}Al{sub 40} layer despite the presence of the mask.

36 MATERIALS SCIENCE↗

Grain boundary effects on defect production and mechanical properties of irradiated nanocrystalline SiC

Grain boundaries (GBs) are known to play an important role in determining the mechanical and functional properties of nanocrystalline materials. In this study, we used molecular dynamics simulations to investigate the effects of damaged GBs on the mechanical properties of SiC that is irradiated by 10 keV Si atoms. The results reveal that irradiation promotes GB sliding and reduces the ability of GBs to block dislocations, which improves the deformation ability of nanocrystalline SiC. However, irradiation causes local rearrangements in disordered clusters and pinning of dislocations in the grain region, which restrains its deformation. These two mechanisms arise from the irradiation effects on GBs and grains, and these mechanisms compete in nanocrystalline SiC during irradiation. The irradiation effects on GBs dominate at low irradiation doses, and the effects on grains dominate at high doses; the result of these combined effects is a peak ductility of 0.09 dpa in nanocrystalline SiC.

36 MATERIALS SCIENCE↗

Influence of irradiation upon few-layered graphene using electron-beams and gamma-rays

Few-layered graphene (FLG) is irradiated by electron beams and gamma rays. After 100 keV electron irradiation, the edges of FLG start bending, shrinking, and finally generate gaps and carbon onions due to sputtering and knock-on damage mechanism. When the electron beam energy is increased further to 200 keV, FLG suffers rapid and catastrophic destruction. Unlike electron irradiation, Compton effect is the dominant damage mechanism in gamma irradiation. The irradiation results indicate the crystallinity of FLG decreases first, then restores as increasing irradiation doses, additionally, the ratio (O/C) of FLG surface and the relative content of oxygen groups increases after irradiation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Detection of irradiated spices using photo-stimulated luminescence technique (PSL)

Photo-stimulated luminescence (PSL) technique was applied to detect irradiated black pepper (Piper nigrum), cinnamon (Cinnamomum verum) and turmeric (Curcuma longa) after dark storage for 1 day, 3 and 6 months. Using screening and calibrated PSL, all samples were correctly discriminated between non-irradiated and spices irradiated with doses 1, 5 and 10 kGy. The PSL photon counts (PCs) of irradiated spices increased with increasing dose, with turmeric showing highest sensitivity index to irradiation compared to black pepper and cinnamon. The differences in response are possibly attributed to the varying quantity and quality of silicate minerals present in each spice sample. PSL signals of all irradiated samples reduced after 3 and 6 months storage. The results of this study provide a useful database on the applicability of PSL technique for the detection of Malaysian irradiated spices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of vacuum-ultraviolet irradiation on copper penetration into low-k dielectrics under bias-temperature stress

The effects of vacuum-ultraviolet (VUV) irradiation on copper penetration into non-porous low-k dielectrics under bias-temperature stress (BTS) were investigated. By employing x-ray photoelectron spectroscopy depth-profile measurements on both as-deposited and VUV-irradiated SiCOH/Cu stacks, it was found that under the same BTS conditions, the diffusion depth of Cu into the VUV-irradiated SiCOH is higher than that of as-deposited SiCOH. On the other hand, under the same temperature-annealing stress (TS) without electric bias, the Cu distribution profiles in the VUV-irradiated SiCOH were same with that for the as-deposited SiCOH. The experiments suggest that in as-deposited SiCOH, the diffused Cu exists primarily in the atomic state, while in VUV-irradiated SiCOH, the diffused Cu is oxidized by the hydroxyl ions (OH{sup −}) generated from VUV irradiation and exists in the ionic state. The mechanisms for metal diffusion and ion injection in VUV irradiated low-k dielectrics are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗