Search NASA⌕ Search

SEARCH · Search NASA

Results for “Inlets”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Comparison and validation of acoustic response models for wind noise reduction pipe arrays

The detection capability of the infrasound component of the International Monitoring System (IMS) is tightly linked to the performance of its wind noise reduction systems. The wind noise reduction solution implemented at all IMS infrasound measurement systems consists of a spatial distribution of air inlets connected to the infrasound sensor through a network of pipes. This system, usually referred to as “pipe array,” has proven its efficiency in operational conditions. The objective of this paper is to present the results of the comparison and validation of three distinct acoustic response models for pipe arrays. The characteristics of the models and the results obtained for a defined set of pipe array configurations are described. A field experiment using a newly developed infrasound generator, dedicated to the validation of these models, is then presented. The comparison between the modeled and empirical acoustic responses shows that two of the three models can be confidently used to estimate pipe array acoustic responses. Lastly, this study paves the way to the deconvolution of IMS infrasound data from pipe array responses and to the optimization of pipe array design to IMS applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reliability of Open Public Electric Vehicle Direct Current Fast Chargers

The aim was to systematically evaluate the usability of all public electric vehicles (EV) direct current fast chargers (DCFC) in the San Francisco region. To achieve a rapid transition to EVs, a highly reliable and easy to use charging infrastructure is critical to building confidence among consumers. The functionality and usability of all 182 open, public DCFC charging stations with CCS connectors (combined charging system) in the 9 counties of the Bay Area were tested (655 electric vehicle service equipment (EVSE) ports). An EVSE was classified as functional if it charged an EV for 2 minutes. Overall, 73.3% of the 655 EVSEs were functional. The causes of the nonfunctioning EVSEs (23.5%) were blank or unresponsive screens or error messages; payment system failures; charge initiation failures; network failures; or broken connectors. In addition, the cable was too short to reach the EV inlet for 3.2% of the EVSEs. A random sampling of 10% of the EVSEs, approximately 8 days after the first evaluation, found no overall change in functionality. The level of functionality found with field testing conflicts with the 95–98% uptime reported by the EV service providers (EVSPs) who operate the EV charging stations. There is a need for precise and verifiable definitions of uptime, downtime, and excluded time, as applied to public EV chargers. In conclusion, the level of failure of the existing public EV DCFC charge infrastructure highlights the importance of improving the system design and maintenance to improve adoption of EVs.

33 ADVANCED PROPULSION SYSTEMS↗

Flow instabilities in non-uniformly heated helium jet arrays used for divertor PFCs

In this study, due to a lack of prototypical experimental data, little is known about the off-normal behavior of recently proposed divertor jet cooling concepts. This article describes a computational fluid dynamics (CFD) study on two jet array designs to investigate their susceptibility to parallel flow instabilities induced by non-uniform heating and large increases in the helium outlet temperature. The study compared a single 25-jet helium-cooled modular divertor (HEMJ) thimble and a micro-jet array with 116 jets. Both have pure tungsten armor and a total mass flow rate of 10 g/s at a 600 °C inlet temperature. We investigated flow perturbations caused by a 30 MW/m 2 off-normal heat flux applied over a 25 mm 2 area in addition to the nominal 5 MW/m 2 applied over a 75 mm 2 portion of the face. The micro-jet array exhibited lower temperatures and a more uniform surface temperature distribution than the HEMJ thimble. We also investigated the response of a manifolded nine-finger HEMJ assembly using the nominal heat flux and a 274 mm 2 heated area. For the 30 MW/m2 case, the micro-jet array absorbed 750 W in the helium with a maximum armor surface temperature of 1280 °C and a fluid/solid interface temperature of 801 °C. The HEMJ absorbed 750 W with a maximum armor surface temperature of 1411 °C and a fluid/solid interface temperature of 844 °C. For comparison, both the single HEMJ finger and the micro-jet array used 5-mm-thick tungsten armor. The ratio of maximum to average temperature and variations in the local heat transfer coefficient were lower for the micro-jet array compared to the HEMJ device. Although high heat flux testing is required to validate the results obtained in these simulations, the results provide important guidance in jet design and manifolding to increase heat removal while providing more even temperature distribution and minimizing non-uniformity in the gas flow and thermal stresses at the armor joint.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TRACE/PARCS Analysis of ATWS with Instability for a MELLLA+BWR/5

A TRACE/PARCS model has been developed to analyze anticipated transient without SCRAM (ATWS) events for a boiling water reactor (BWR) operating in the maximum extended load line limit analysis-plus (MELLLA+) expanded operating domain. The MELLLA+ domain expands allowable operation in the power/flow map of a BWR to low flow rates at high power conditions. Such operation exacerbates the likelihood of large amplitude power/flow oscillations during certain ATWS scenarios. The analysis shows that large amplitude power/flow oscillations, both core-wide and out-of-phase, arise following the establishment of natural circulation flow in the reactor pressure vessel (RPV) after the trip of the recirculation pumps and an increase in core inlet subcooling. The analysis also indicates a mechanism by which the fuel may experience heat-up that could result in localized fuel damage. TRACE predicts the heat-up to occur when the cladding surface temperature exceeds the minimum stable film boiling temperature after periodic cycles of dryout and rewet; and the fuel becomes “locked” into a film boiling regime. Further, the analysis demonstrates the effectiveness of the simulated manual operator actions to suppress the instability.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Study of Convection Heat Transfer in a Very High Temperature Reactor Flow Channel: Numerical and Experimental Results

Very High Temperature Reactors (VHTRs) are one of the Generation IV gas-cooled reactor models proposed for implementation in next generation nuclear power plants. A high temperature/pressure test facility for forced and natural circulation experiments has been constructed. This test facility consists of a single flow channel in a 2.7 m (9’) long graphite column equipped with four 2.3kW heaters. Extensive 3D numerical modeling provides a detailed analysis of the thermal-hydraulic behavior under steady-state, transient, and accident scenarios. In addition, forced/mixed convection experiments with air, nitrogen and helium were conducted for inlet Reynolds numbers from 500 to 70,000. Our numerical results were validated with forced convection data displaying maximum percentage errors under 15%, using commercial finite element package, COMSOL Multiphysics. Based on this agreement, important information can be extracted from the model, with regards to the modified radial velocity and property gas profiles. Our work also examines flow laminarization for a full range of Reynolds numbers including laminar, transition and turbulent flow under forced convection and its impact on heat transfer under various scenarios to examine the thermal-hydraulic phenomena that could occur during both normal operation and accident conditions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Eliminating Signal Bias Caused by Vacuum System Backstreaming in the Diagnostic Residual Gas Analyzer of ITER

In fusion neutral gas analysis, such as with the Diagnostic Residual Gas Analyzer (DRGA) for ITER, the primary measurement range of interest comprises the low-amu species (1 to 6), especially deuterium and helium. The challenge in successfully obtaining accurate measurements is two-fold. First, the sensitivity of the method must be sufficient to resolve trace amounts accurately; typically, one percent or less. Second, the gas signal from the fusion processes must be free of bias caused by the latent presence (from system outgassing and/or vacuum backstreaming) of these gases to enable accurate interpretation of the measured signal. This latter criterion can be problematic for the lightest gases since there is a propensity for some fraction of the pumped gas load to undergo a phenomenon known as backstreaming. This behavior is manifested in pumping systems for gas properties related to relative atomic weight (lightest) and size (smallest). Backstreaming results in a significant amount of the pumped gas undertaking a reverse flow and re-entering the measurement region; thus, contaminating the forward, real-time measurement. To fully eliminate this adverse effect, a conductance-limiting device – or orifice – has been installed in the high-vacuum pumping system of the present ITER DRGA prototype. The system was already equipped with a secondary turbomolecular pump (TMP), but with limited effectiveness against backstreaming in the inter-pump volume (IPV). This orifice is placed within the suction inlet coupling of the secondary TMP, which is downstream of the IPV. Its objective is to eliminate the backstreaming phenomenon by increasing the back pressure in the IPV. However, the orifice sizing must take into consideration other factors, such as the diagnostic measurement objectives. For example, in the ITER DRGA, one of the measurement requirements is a dynamic response time of ~1s. Fortunately, an added benefit of the pumping restriction created by the orifice is that the upstream pressure increase is beneficial for the DRGA’s optical gas analysis (OGA) sensors. These sensors are attached to the IPV in the present design. The glow discharges, when used as an OGA light source, will typically have a brighter light emission with increasing plasma cell pressure. In addition to the fusion machine research sector, there are other potential applications of this pumping technique where the monitoring of lighter gas concentrations is essential, such as the photolithography process for the semiconductor fabrication of integrated circuits. This presentation will describe the vacuum system used to demonstrate a process to eliminate backstreaming as well as show test results to verify the accomplishment of this critical objective.

Marcus, Chris↗

GEOPHIRES Simulations for Deep Direct Use (DDU) Projects

This folder contains the GEOPHIRES codes and input files for running the base case scenarios for the six deep direct-use (DDU) projects. The six DDU projects took place during 2017-2020 and were funded by the U.S. Department of Energy Geothermal Technologies Office. They investigated the potential of geothermal deep direct-use at six locations across the country. The projects were conducted by Cornell University, West Virginia University (WVU), University of Illinois (U of IL), Sandia National Laboratory (SNL), Portland State University (PSU), and National Renewable Energy Laboratory (NREL). Four projects (Cornell, WVU, U of IL, SNL) investigated geothermal for direct heating of a local campus or community, the project by PSU considered seasonal subsurface storage of solar heating, and the NREL project investigated geothermal heating for turbine inlet cooling using absorption chillers. To allow comparison of techno-economic results across the six DDU projects, GEOPHIRES simulations were set up and conducted for each project. The GEOPHIRES code was modified for each project to simulate the local application and incorporate project-specific assumptions and results such as reservoir production temperature or financing conditions. The base case input file is included which simulates the base case conditions assumed by each project team. The levelized cost of heat (LCOH) is calculated and matches the base case LCOH reported by the project teams.

15 GEOTHERMAL ENERGY↗

Advanced TidGen Power System - LCOE Calculations and System Overview

The TidGen Power System generates emission-free electricity from tidal currents and connects directly into existing grids using smart grid technology. The power system consists of three major subsystems: shore-side power electronics, mooring system, and turbine generator unit (TGU) device. This submission includes the Advanced TidGen cost and cost of energy metrics after critical design review for BP1, and a complete LCOE content model and LCOE reporting according to DOE guidance for the baseline system and the system with advanced technology integrated. A revised LCOE content model is also included, with more relevant market array assumptions. Additionally, this submission includes a complete system overview and component overview content models. The LCOE Content Model provides data submitters with an easy and consistent means of uploading data that can be used to calculate the levelized cost of energy for MHK devices. Data represents the design completed for the Critical Design Review conducted at ORPC in December, 2017. All values are for a single device. Note that with substantial fixed costs, larger arrays will greatly reduce LCOE. For an array in Admiralty Inlet producing 136,000 MWh, 270 devices with an array CAPEX of $540,260,052 and an array OPEX of $39,959,207 would result in an LCOE of $722/MWh.

16 TIDAL AND WAVE POWER↗

HERO WEC V1.0 - WEC-Sim Detailed Simulation Runs and Summary Data

Data sets from simulation runs include 144 wave cases that were run based on the WEC-Sim model (https://mhkdr.openei.org/submissions/483). The 144 wave cases represent waves with the following wave height and wave period ranges: - Significant Wave Height: 0.25 - 4.0m in 0.25m increments - Wave Period: 5 - 13 sec in 1 sec increments Each run was simulated using a Pierson-Moskowitz irregular wave spectrum with a 200 second ramp time and a total simulation time of 2,200 seconds. Summary data set includes a spreadsheet and image files with matrices that are associated with data from simulation runs. All matrices cover the same significant wave height and wave periods from the sim runs, in the same increments. The following matrices are included: - Mechanical Power Input: Absorbed power calculated using linear input velocity at PTO (power take-off) multiplied by winch tension. - Mechanical Power Output: The hydraulic power calculated at the pump output prior to the pressure relief valve dump. - Feed Pressure: Average pressure at RO (reverse osmosis) input prior to pre-filters - RO Power Input: The hydraulic power calculated at the RO system inlet, accounts for flow loss due to pressure relief valve - Water Production: Average clean water flow at RO output

16 TIDAL AND WAVE POWER↗

Model, data, and code for paper "Modeling of streamflow in a 30-kilometer-long reach spanning 5 years using OpenFOAM 5.x"

The data package includes data, model, and code that support the analyses and conclusions in the paper titled “modeling of streamflow in a 30-kilometer-long reach spanning 5 years using OpenFOAM 5.x”. The primary goal of this paper is to demonstrate that key streamflow properties such as water depth, flow velocity, and dynamic pressure in a natural river at 30-kilometer scale over 5 years can be reliably and efficiently modeled using the computational framework presented in this paper. To support the paper, various data types from remote sensing, field observations, and computational models are used. Specific details are described as follows. Firstly, the river bathymetry data was obtained from a Light Detection and Ranging (LiDAR) survey. This data is then converted to a triangulated surface format, STL, for mesh generation in OpenFOAM. The STL data can be found in Model_Setups/BaseCase_2013To2015/constant/triSurface. The OpenFOAM mesh generated using this STL file can be found in constant/polyMesh. Other model setups, boundary and initial conditions can be found in /system and /0.org under folder BaseCase_2013To2015. A similar data structure can also be found in BaseCase_2018To2019 for the simulations during 2018 and 2019. Secondly, the OpenFOAM simulations need the upstream discharge and water depth information at the upstream boundary to drive the model. These data are generated from a one-dimensional hydraulic model and the data can be found under the folder Model_Setups /1D model Mass1 data. The mass1_65.csv and mass1_191.csv files include the results of the 1D model at the model inlet and outlet, respectively. The Matlab source code Mass1ToOFBC20182019.m is used to convert these data into OpenFOAM boundary condition setups.With the above OpenFOAM model, it can generate data for water surface elevation, flow velocity, and dynamic pressure. In this paper, the water surface elevation was measured at 7 locations during different periods between 2011 and 2019. The exact survey locations (see Fig1_SurveyLocations.txt) can be found in folder Fig_1. The variation of water stage over time at the 7 locations can be found in folder /Observation_WSE. The data type include .txt, .csv, .xlsx, and .mat. The .mat data can be loaded by Matlab.We also measured the flow velocities at 12 cross-sections along the river. At each cross-section, we recorded the x, y locations, depth, three velocity components u,v,w. These data are saved to a Matlab format which can be found under folder /Observation_Velocity and /Fig_1. The relative locations of velocity survey locations to the river bathymetry can be found in Figure 1c.The water stage data at the 7 locations from OpenFOAM, 1D, and 2D hydraulic models are also provided to evaluate the long-term performance of 3D models vs 1D/2D models. The water stage data for the 7 locations from OpenFOAM have been saved to .mat format and can be found in /OpenFOAM_WSE. The water stage data from the 1D model are saved in .csv format and can be found in /Mass1_WSE. The water stage from the 2D model is saved as .mat format and can be found in / Mass2_WSEIn addition, the OpenFOAM model outputs the information of hydrostatic and hydrodynamic pressure. They are saved as .mat format under folder /Fig_11/2013_1. As the files are too large, we only uploaded the data for January 2013. The area of different ratio of dynamic pressure to static pressure for all simulation range, i.e., 2013-2015, are saved to .mat format. They can be found in /Fig_11/PA. Further, the data of wall clock time versus the solution time of the OpenFOAM modeling are also saved to .mat format under folder /Fig_13/LogsMat. In summary, the data package contains seven data types, including .txt, .csv, .xlsx, .dat, .stl, .m, and .mat. The former 4 types can be directly open using a text editor or Microsoft Office. The .mat format needs to be read by Matlab. The Matlab source code .m files need to be run with Matlab. The OpenFOAM setups can be visualized in ParaView. The .stl file can be opened in ParaView or Blender. The data in subfolders Fig_1 to Fig_10 and Fig_12 are copied from the aforementioned data folders to generate specific figures for the paper. A readME.txt file is included in each subfolder to further describe how the data in each folder are generated and used to support the paper.Please use the data package's DOI to cite the data package. Please contact yunxiang.chen@pnnl.gov if you need more data related to the paper.

54 ENVIRONMENTAL SCIENCES↗

Biogeochemistry of Pond B (Savannah River Site, South Carolina, USA): Water column and Sediments

Pond B at Savannah River Site (SRS, South Carolina) is a monomictic reservoir that received SRS R reactor cooling water from 1961–1964. Previous studies conducted between the 1980s–1990s on the water column and sediments of Pond B measured trace amounts of Pu (33 MBq 238Pu and 430 MBq 239,240Pu), 241Am, and 137Cs. Since then, the pond has been relatively isolated and the radionuclide concentrations have not been monitored over time. Herein, about 30 years after the last publication on Pond B, we are re-evaluating the geochemistry and radionuclide distribution within Pond B at five locations along a horizontal transect from the inlet to outlet. In addition, we are conducting the first analysis of the microbial community composition. This data package consists of water column measurements (1) using a multi-probe sonde, (2) plutonium isotopes and total concentrations, (3) total organic/inorganic carbon concentrations, (4) trace metals and major ions concentrations, and (6) microbial community composition. Sediment measurements include (1) plutonium isotopes and total concentrations and (2) microbial community composition.For sediment core and porewater, please see other Pond B data package (ess-dive-60d2352a4495472-20200615T203925174).The data in this package will be submitted for peer review in 2023.

54 ENVIRONMENTAL SCIENCES↗

Biogeochemistry of Pond B (Savannah River Site, South Carolina, USA): Sediment Core, Total extraction data, Pond B Savannah River Site July 2019. Subsurface Biogeochemistry of Actinides SFA

Pond B at Savannah River Site (SRS, South Carolina) is a monomictic reservoir that received SRS R reactor cooling water from 1961–1964. Previous studies conducted between the 1980s–1990s on the water column and sediments of Pond B measured trace amounts of Pu (33 MBq 238Pu and 430 MBq 239,240Pu), 241Am, and 137Cs. Since then, the pond has been relatively isolated and the radionuclide concentrations have not been monitored over time. Herein, about 30 years after the last publication on Pond B, we are re-evaluating the geochemistry and radionuclide distribution within Pond B at four locations along a horizontal transect from the inlet to outlet.This study investigated the distribution of anthropogenic radionuclides Pu-239 and Cs-137 along with total organic carbon, iron, and trace element in contaminated sediments of Pond B at the Savannah River Site (SRS). Pond B received reactor cooling water from 1961 to 1964, and trace amounts of Pu-239 and Cs-137 during operations. Our study collected sediment cores to determine concentrations of Pu-239, Cs-137, and major and minor elements in solid phase, pore water and an electrochemical method was used on wet cores to determine dissolved elemental concentrations.

54 ENVIRONMENTAL SCIENCES↗

Core-flood Effluent and Shale Surface Chemistries in Predicting Interaction between Shale, Brine, and Reactive Fluid

We report field and laboratory observations to date indicate that the efficiency of hydraulic fracturing, as it relates to hydrocarbon recovery, depends significantly on geochemical alterations to rock surfaces that diminish accessibility by partial or total plugging of the pore and fracture networks. This is caused by mineral scale deposition such as coating of fracture surfaces with precipitates, particle migration, and/or crack closure due to dissolution under stress. In reactive flow-through experiments, mineral reactions in response to acidic fluid injection significantly reduced system porosity and core permeability. The present study focuses on changes to fluid chemistry and shale surfaces (inlet and fracture walls) resulting from shale-fluid interactions and integrating these findings for an improved estimate of transport-related consequences. The reacted shale surfaces were examined by spatially-resolved scanning electron microscopy - energy dispersive spectroscopy (SEM-EDS) analysis. Importantly, inductively coupled plasma - mass spectrometry/optical emission spectroscopy (ICP-MS/OES) was utilized to probe the chemical evolution of the core-flood effluents. The three study cores selected from the Marcellus formation represent different mineralogies and structural features. In flow-through experiments, lab-generated brine and HCl-based fracture fluid (pH=2) were injected sequentially under effective stress (up to 500 psi) at reservoir temperature (80°C). SEM-EDS results confirmed by the ICP concentration trends showed significant Fe hydroxide precipitates in clay- and pyrite-rich outcrop samples due to partial oxidation of Fe-bearing phases in the case of intrusion of low salinity water-based fluids. Porosity reduction in the MSEEL (Marcellus Shale Energy and Environmental Laboratory) carbonate-rich sample is related to compaction of cores under stress due to matrix softening with substantial dissolution, and pore-filling by hydroxides, as well as barite and salts. Despite the same fluid compositions and experimental conditions used for both MSEEL samples, barite precipitation was much more intense in the MSEEL clay-rich sample due to its greater sorption capacity and additional sulfate source as well as fissile nature with multiple lengthwise cracks. ICP tests revealed time-resolved concentration trends in produced brine and reactive fluids that in turn complemented the pre-/post-reaction SEM-EDS observations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-speed phase contrast imaging of spray breakup of jet fuels under combusting conditions

X-ray phase contrast imaging is conducted at 90,517 Hz on a fuel spray to characterize the breakup of the bulk fuel into ligaments and individual droplets in a single-sector, swirl-stabilized combustor under reacting conditions. Phase contrast imaging is used to qualitatively assess spray breakup for two fuels: Jet-A, which represents a normal viscosity fuel, and a blend of JP-5 (64%) and farnesane (36% by volume), which represents a high-viscosity fuel, at three fuel-flow rates and two air inlet temperatures. Time-series images of the fuels show that atomization occurs much more rapidly at higher fuel pressure with thinner ligaments being rapidly shredded. The high-viscosity fuel is qualitatively observed to have markedly longer, thicker ligaments and larger droplet diameters after the primary breakup than the normal viscosity fuel. Using an image processing and droplet quantification strategy, the mean droplet velocity magnitudes were found to decrease with decreasing fuel pressure and fuel-flow rate. The increase in preheat temperature from 323 to 370 K results in an increase in the mean droplet velocity magnitude and a decrease in numerical average and Sauter mean diameter, indicating improved atomization. The high-viscosity fuel was found to have larger average droplet diameters at each condition than the normal viscosity fuel. The increased preheat is found to enhance the combustion efficiency, which is hypothesized to couple with the improved atomization due to the higher combustion temperatures. This indicates the importance of examining spray atomization and breakup under realistic combusting conditions for relevant fuels as the heat release directly couples with the atomization process.

42 ENGINEERING↗

High flux boiling heat transfer enhancement using triangle shaped vertical walls in two-phase microchannel heat exchangers

Two-phase heat exchangers allow heat loads to be dissipated with lower fluid flow rates without inducing thermal gradients, and high surface area microchannels further reduce the thermal resistance of these heat exchangers. However, there are many practical limits that prevent widespread use of two-phase microchannel heat exchangers. Many authors have looked to address these practical limits by treating the channel floors or creating artificial nucleation sites. Few works look to enhance heat transfer in the walls of channels with hydraulic diameters below 200 μm. This work is aimed at increasing the efficacy of high aspect ratio silicon microchannels that use R134a as the working fluid. The 125 parallel channels are 40 μm wide, 200 μm deep, and 2 mm long and contain a 15 μm wide, 150 μm long restriction at each inlet. The thermal resistance and dryout characteristics of traditional, plain-walled channels are compared to channels with 2 area enhancement patterns each of which increases the area available for heat transfer by 41%. Furthermore, a resistance to dryout is seen in both area-enhanced test sections, and a 15.5% reduction in thermal resistance is shown for the area-enhanced part with a 6 μm triangular pitch. Only a 7.8% performance increase is seen in the test section with a 3 μm pitch. Both area enhancement patterns induce an average 27% increase in pressure drop for all tests. Heat transfer characteristics are solved for using a finite element analysis (FEA) model. By examining heat transfer coefficients and local heat fluxes, it is postulated that the area enhancement reduces heat transfer coefficients and the performance increase is caused by increasing the number of active nucleation sites.

42 ENGINEERING↗

Effects of additively manufactured surface roughness on small diameter plenums with multiple side discharges for high temperature gas turbine blade cooling applications

Combined heat and power (CHP) applications have significant environmental and economic benefits that are consistent with the goals of the U.S. Department of Energy (DOE). One area that is currently being studied includes the potential benefits of CHP turbine operation at higher turbine inlet temperatures. Internal cooling concepts enabled by additive manufacturing (AM) are of primary interest. Here, the effectiveness of internal cooling is hindered by many factors such as velocity distribution of the cooling air to the hot surface considering impingement cooling. To simulate cooling air exiting from a series of orifices for internal cooling in an airfoil, a straight smooth wall tubing with multiple side discharging orifices is used and compared to additively manufactured tubing (Ti6Al4V Grade 23) with orifice size and spacing as well as inner and outer diameters identical to the smooth wall tubing. Similar to flow discharging form perforated pipes, the flow discharged from individual orifices along the tubes in this study is found to be nonuniformly distributed, and the horizontal (axial direction) momentum can be observed from the experimental data. Discharge velocities have been measured with two-dimensional (2D) particle imaging velocimetry (PIV) and single element hot wire anemometry. Numerical analysis has also been conducted to predict the velocity distributions along the orifices in the smooth wall and additive manufacturing (AM) tubing, which are inherited with surface roughness. Numerical and measured results in this study are compared, presented, and discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Resolving the Energy–Water Nexus in Large Thermoelectric Power Plants: A Case for Application of Enhanced Heat Transfer and High-Performance Thermal Energy Storage

The acute energy and water consumption stress on global economies warrants a reexamination of the energy–water nexus and urgent innovative engineering solutions. To address the attendant challenges in large-scale thermoelectric power plants, especially where evaporative cooling towers are used that consume more than 73% of their annual cooling water withdrawals, a transformative dry-cooling (or air-cooling) system is proposed in this paper, which consists of a novel daytime peak-load shifting system that pre-cools the daytime peak-temperature air in order to mitigate concomitant second-law limitation for air cooling. The highly compact and enhanced air pre-cooler transfers the daytime heat load to a unique thermal energy storage (TES) system. The TES operates over a range of temperatures and is recharged by an asynchronous nighttime air-cooled exchanger. Moreover, the air-cooled condenser (ACC) is designed with an enhanced surface core, with substantially higher heat transfer coefficients, such that it operates with a smaller inlet temperature difference. This allows the ACC to sustain lower condensing pressures. Thus, the system not only makes dry air cooling (zero net water dissipation for cooling) viable but also significantly increases the power plant output.

36 MATERIALS SCIENCE↗

PINCH POINT ANALYSIS OF GAS COOLERS IN TRANSCRITICAL R1336mzz(Z) HIGH-TEMPERATURE HEAT PUMPS

The majority of high-temperature heat pumps (HTHPs) operate subcritical vapor compression cycles, where the maximum sink temperature is limited by the critical temperature of refrigerants. In HTHPs with a sink temperature of ≥ 150°C, transcritical cycles overcome this limitation by rejecting heat in the supercritical regions of refrigerant. Supercritical refrigerants in gas coolers have a large temperature glide and substantial nonlinear variation in specific heat capacity vs. temperature. Closely matching the refrigerant glide temperature and the heat sink temperature profile greatly impacts the heat transfer characteristic of gas coolers and the overall performance of HTHPs. This study conducts a pinch point analysis for the gas cooling process of supercritical R1336mzz(Z) in HTHPs. A finite volume element model of a supercritical R1336mzz(Z) counterflow gas cooler is built and solved. This study evaluates the influences of operating conditions, including inlet and outlet of coolants, refrigerant evaporation temperature and superheat degree, pinch temperature difference, and heat rejection pressure, on the performance of HTHPs. The optimal discharge pressures in gas coolers are proposed for industrial spray dryers in providing drying air at 170°C−210°C. The results of the present study help design gas coolers in transcritical R1336mzz(Z) HTHPs.

Wang, Pengtao↗