Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linear accelerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

A Study of Excited Charm-Strange Baryons withEvidence for new Baryons Xi_c(3055)+ and Xi_c(3123)+

We present a study of excited charm-strange baryon states produced in e{sup +}e{sup -} annihilations at or near a center-of-mass energy of 10.58 GeV, in a data sample with an integrated luminosity of 384 fb{sup -1} recorded with the BABAR detector at the PEP-II e+e storage rings at the Stanford Linear Accelerator Center. We study strong decays of charm-strange baryons to {Lambda}{sub c}{sup +}K{sub S}{sup 0}, {Lambda}{sub c}{sup +}K{sup -}, {Lambda}{sub c}{sup +}K{sup -}{pi}{sup +}, {Lambda}{sub c}{sup +}K{sub S}{sup 0}{pi}{sup -}, {Lambda}{sub c}{sup +}K{sub S}{sup 0}{pi}{sup -}{pi}{sup +}, {Lambda}{sub c}{sup +}K{sup -}{pi}{sup -}{pi}{sup +}. This study confirms the existence of the states {Xi}{sub c}(2980){sup +}, {Xi}{sub c}(3077){sup +}, and {Xi}{sub c}(3077){sup -}, with a more accurate determination of the {Xi}{sub c}(2980){sup +} mass and width. We also present evidence for two new states, {Xi}{sub c}(3055){sup +} and {Xi}{sub c}(3123){sup +}, decaying through the intermediate resonant modes {Sigma}{sub c}(2455){sup ++}K{sup -} and {Sigma}{sub c}(2520){sup ++}K{sup -}, respectively. For each of these baryons, we measure the yield in each final state, determine the statistical significance, and calculate the product of the production cross-section and branching fractions. We also measure the masses and widths of these excited charm-strange baryons.

43 PARTICLE ACCELERATORS↗

Leptonic Decays at BABAR

We present recent results on leptonic B decays using data collected by the BaBar detector at the PEP-II asymmetric-energy e+e- collider at the Stanford Linear Accelerator Center. We report searches for the B{sup +} {yields} {tau}{sup +}{nu} decay based on two statistically independent data samples.

43 PARTICLE ACCELERATORS↗

Determination of the b-quark Mass and Nonperturbative parameters in Semileptonic and Radiative Penguin Decays at BaBar

Knowing the mass of the b-quark is essential to the study of the structure and decays of B mesons as well as to future tests of the Higgs mechanism of mass generation. We present recent preliminary measurements of the b-quark mass and related nonperturbative parameters from moments of kinematic distributions in charmed and charmless semileptonic and radiative penguin B decays. Their determination from charmless semileptonic B decays is the first measurement in this mode. The data were collected by the BABAR detector at the PEP-II asymmetric-energy e{sup +}e{sup -}-collider at the Stanford Linear Accelerator Center at a center-of-momentum energy of 10:58 GeV.

43 PARTICLE ACCELERATORS↗

Observation of B^+\to\eta\rho^+ and Search for B^0 Decays to\eta^\prime\eta, \eta\pi^0, \eta^\prime\pi^0, and \omega\pi^0

The authors present measurements of branching fractions for five B-meson decays to two-body charmless final states. The data, collected with the BABAR detector at the Stanford Linear Accelerator Center, represent 459 million B{bar B} pairs. The results for branching fractions are, in units of 10{sup -6} (upper limits at 90% C.L.): {Beta}(B{sup +} {yields} {eta}{rho}{sup +}) = 9.9 {+-} 1.2 {+-} 0.8, {Beta}(B{sup 0} {yields} {eta}{prime}{eta}) = 0.5 {+-} 0.4 {+-} 0.1 (< 1.2), {Beta}(B{sup 0} {yields} {eta}{pi}{sup 0}) = 0.9 {+-} 0.4 {+-} 0.1 (< 1.5), {Beta}(B{sup 0} {yields} {eta}{prime}{pi}{sup 0}) = 0.9 {+-} 0.4 {+-} 0.1 (< 1.5), and {Beta}(B{sup 0}{sup 0} {yields} {omega}{pi}{sup 0}) = {eta}{rho}{sup +} mode, they measure the charge asymmetry {Alpha}{sub ch} (B{sup +} {yields} {eta}{rho}{sup +}) = 0.13 {+-} 0.11 {+-} 0.02.

43 PARTICLE ACCELERATORS↗

Search for B+ Meson Decay to a1+ K*0

We present the preliminary result of a search for the decay B{sup {+-}} {yields} a{sub 1}{sup {+-}} K*{sup 0}. The data, collected with the BABAR detector at the Stanford Linear Accelerator Center, represent 465 million B{bar B} pairs produced in e{sup +}e{sup -} annihilation at the {Upsilon}(4S) energy. The result for the branching fraction is: {Beta}(B{sup +} {yields} a{sub 1}{sup +}K*{sup 0}) x {Beta}(a{sub 1}{sup +} {yields} {pi}{sup +}{pi}{sup -}{pi}{sup +}) = (0.7{sub -0.4-0.7}{sup +0.5+0.7}) x 10{sup -6}, corresponding to an upper limit at 90% confidence level of 1.6 x 10{sup -6}. The first error quoted is statistical, the second systematic.

43 PARTICLE ACCELERATORS↗

Measurements of Branching Fractions for B+ -> rho+ gamma, B0 -> rho0 gamma, and B0 -> omega gamma

The authors present branching fraction measurements for the radiative decays B{sup +} {yields} {rho}{sup +}{gamma}, B{sup 0} {yields} {rho}{sup 0}{gamma}, and B{sup 0} {yields} {omega}{gamma}. The analysis is based on a data sample of 465 million B{bar B} events collected with the BABAR detector at the PEP-II asymmetric-energy B Factory located at the Stanford Linear Accelerator Center (SLAC). They find {Beta}(B{sup +} {yields} {rho}{sup +}{gamma}) = (1.20{sub -0.37}{sup +0.42} {+-} 0.20) x 10{sup -6}, {Beta}(B{sup 0} {yields} {rho}{sup 0}{gamma}) = (0.97{sub -0.22}{sup +0.24} {+-} 0.06) x 10{sup -6}, and a 90% C.L. upper limit {Beta}(B{sup 0} {yields} {omega}{gamma}) < 0.9 x 10{sup -6}, where the first error is statistical and the second is systematic. They also measure the isospin-violating quantity {Lambda}(B{sup +} {yields} {rho}{sup +}{gamma})/2{Lambda}(B{sup 0} {yields} {rho}{sup 0}{gamma}) - 1 = -0.43{sub -0.22}{sup +0.25} {+-} 0.10.

43 PARTICLE ACCELERATORS↗

Design and Test of a 100MW X Band TE01 Window

Research at Stanford Linear Accelerator Center (SLAC) is in progress on a TeV-scale linear collider that will operate at 5-10 times the energy of present generation accelerators. This will require development of high power X-Band sources generating 50-100 MW per source. Conventional pillbox window designs are capable of transmitting peak rf powers up to about 30 MW, well below the desired level required for the use of a single window per tube. SLAC has developed a 75 MW TE{sub 01} window [1] that uses a 'traveling wave' design to minimize fields at the window face. Irises match to the dielectric window impedance, resulting in a pure traveling wave in the ceramic and minimum fields on the window face. The use of the TE{sub 01} mode also has zero electric field on the braze fillet. Unfortunately, in-band resonances prevented this window design from achieving the desired 75MW power level. It was believed the resonances resulted from sudden steps in the circular guide to match the 38mm input diameter to the overmoded (TE{sub 01} and TE{sub 02} mode propagating) 65 mm diameter of the window ceramic. Calabazas Creek Research Inc. is currently developing a traveling wave window using compact, numerically optimized, parabolic tapers to match the input diameter of 38mm to the window ceramic diameter of 76mm (Figure 1). The design is projected to handle 100 MW of pulse power with a peak field at the window face of 3.6 MV/m. Cold test of the window has shown the return loss to be better than -25 dB over a 100 MHz bandwidth and to be resonance free (Figure 2). The window is scheduled for high-power testing in July 2003 at the SLAC.

36 MATERIALS SCIENCE↗

Amplitude-dependent orbital period in alternating gradient accelerators

Orbital period in a ring accelerator and time of flight in a linear accelerator depend on the amplitude of betatron oscillations. The variation is negligible in ordinary particle accelerators with relatively small beam emittance. In an accelerator for large emittance beams like muons and unstable nuclei, however, this effect cannot be ignored. In this study, we measured orbital period in a linear non-scaling fixed-field alternating-gradient accelerator, which is a candidate for muon acceleration, and compared it with the theoretical prediction. The good agreement between them gives important ground for the design of particle accelerators for a new generation of particle and nuclear physics experiments.

43 PARTICLE ACCELERATORS↗

The ALTO Facility for the Production of Rare Nuclei

The ALTO facility (Accelerateur Lineaire et Tandem d'Orsay) at Institut de Physique Nucleaire d'Orsay is under commissioning. The main aim of this facility is to provide neutron rich isotope beams for both nuclear physics studies (away from the valley of stability) and developments dedicated to next generation facilities such as SPIRAL2 (Systeme de Production d'Ions Radioactifs Acceleres en Ligne 2). The neutron rich isotopes are produced by photofission of {sup 238}U induced by the 50 MeV electrons from the linear accelerator. The isotopes coming out of the fission target effuse towards an ion source to form a beam that is analyzed through the on line separator PARRNe (Production d'Atomes Radioactifs Riches en Neutrons). Additional experimental beam lines are currently under construction. Experimental data obtained during the commissioning phase will be presented and compared to simulations. The ALTO facility is also aimed at being a test bench for the SPIRAL2 and the EURISOL-DS (European Isotope Separation On-Line--Design Study) projects. In that framework, a plasma ion source designed to produce radioactive beams under strong irradiation is being developed; a prototype of the IRENA (Ionization by Radial Electrons Neat Adaptation) ion source will be presented.

43 PARTICLE ACCELERATORS↗

Prototyping of beam position monitor for medium energy beam transport section of RAON heavy ion accelerator

A heavy ion accelerator, RAON is going to be built by Rare Isotope Science Project in Korea. Its target is to accelerate various stable ions such as uranium, proton, and xenon from electron cyclotron resonance ion source and some rare isotopes from isotope separation on-line. The beam shaping, charge selection, and modulation should be applied to the ions from these ion sources because RAON adopts a superconducting linear accelerator structure for beam acceleration. For such treatment, low energy beam transport, radio frequency quadrupole, and medium energy beam transport (MEBT) will be installed in injector part of RAON accelerator. Recently, development of a prototype of stripline beam position monitor (BPM) to measure the position of ion beams in MEBT section is under way. In this presentation, design of stripline, electromagnetic (EM) simulation results, and RF measurement test results obtained from the prototyped BPM will be described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Production of low-Z ions in the Dresden superconducting electron ion beam source for medical particle therapy

We report on experiments with a new superconducting electron beam ion source (EBIS-SC), the Dresden EBIS-SC, with the objective to meet the main requirements for their application in particle-therapy facilities. Synchrotrons as well as innovative accelerator concepts, such as high-gradient linacs which are driven by a large-current cyclotron (CYCLINACS) and direct drive RF linear accelerators may benefit from the advantages of EBISs in regard to their functional principle. First experimental studies of the production of low-Z ions such as H{sup +}, H{sub 2}{sup +}, H{sub 3}{sup +}, C{sup 4+}, and C{sup 6+} are presented. Particular attention is paid to the ion output, i.e., the number of ions per pulse and per second, respectively. Important beam parameters in this context are, among others, ion pulse shaping, pulse repetition rates, beam emittance, and ion energy spread.

43 PARTICLE ACCELERATORS↗

Radiotherapy and Nuclear Medicine Project for an Integral Oncology Center at the Oaxaca High Specialization Regional Hospital

A building project of Radiotherapy and Nuclear Medicine services (diagnostic and therapy), within an Integral Oncology Center (IOC), requires interdisciplinary participation of architects, biomedical engineers, radiation oncologists and medical physicists. This report focus on the medical physicist role in designing, building and commissioning stages, for the final clinical use of an IOC at the Oaxaca High Specialization Regional Hospital (HRAEO). As a first step, during design stage, the medical physicist participates in discussions about radiation safety and regulatory requirements for the National Regulatory Agency (called CNSNS in Mexico). Medical physicists propose solutions to clinical needs and take decisions about installing medical equipment, in order to fulfill technical and medical requirements. As a second step, during the construction stage, medical physicists keep an eye on building materials and structural specifications. Meanwhile, regulatory documentation must be sent to CNSNS. This documentation compiles information about medical equipment, radioactivity facility, radiation workers and nuclear material data, in order to obtain the license for the linear accelerator, brachytherapy and nuclear medicine facilities. As a final step, after equipment installation, the commissioning stage takes place. As the conclusion, we show that medical physicists are essentials in order to fulfill with Mexican regulatory requirements in medical facilities.

07 ISOTOPE AND RADIATION SOURCES↗

Design parameters and commissioning of vertical inserts used for testing the XFEL superconducting cavities

The European XFEL is a new research facility currently under construction at DESY in the Hamburg area in Germany. From 2015 on, it will generate extremely intense X-ray flashes that will be used by researchers from all over the world. The superconducting XFEL linear accelerator consists of 100 accelerator modules with more than 800 RF-cavities inside. The accelerator modules, superconducting magnets and cavities will be tested in the accelerator module test facility (AMTF). This paper gives an overview of the design parameters and the commissioning of the vertical insert, used in two cryostats (XATC) of the AMTF-hall. The Insert serves as a holder for 4 nine-cell cavities. This gives the possibility to cool down 4 cavities to 2K in parallel and, consequently, to reduce the testing time. The following RF measurement, selected as quality check, will be done separately for each cavity. Afterwards the cavities will be warmed up again and will be sent to the accelerator module assembly.

43 PARTICLE ACCELERATORS↗

Measurement of Ratios of Branching Fractions and CP-Violating Asymmetries of B+/- --> D*K +/- decays

The authors report a study of B{sup {+-}} {yields} D*K{sup {+-}} decays with D* decaying to D{pi}{sup 0} or D{gamma}, using 383 x 10{sup 6} B{bar B} pairs collected at the {Upsilon}(4S) resonance with the BABAR detector at the SLAC PEP-II B-Factory. The D meson decays under study include a non-CP mode (K{sup {+-}}{pi}{sup {-+}}), CP-even modes (K{sup {+-}}K{sup {-+}}, {pi}{sup {+-}}{pi}{sup {-+}}) and CP-odd modes (K{sub S}{sup 0}{pi}{sup 0}, K{sub S}{sup 0}{phi}, K{sub S}{sup 0}{omega}). They measure ratios (R*{sub CP{+-}}) of branching fractions of decays to CP eigenmode states and to flavor-specific states as well as CP asymmetries A*{sub CP{+-}} = -0.11 {+-} 0.09 {+-} 0.01, R*{sub CP+} = 1.31 {+-} 0.13 {+-} 0.04, and A*{sub CP-} = 0.06 {+-} 0.10 {+-} 0.02, R*{sub CP-} = 1.10 {+-} 0.12 {+-} 0.04, where the first error is statistical and the second error is systematic. Translating the results into an alternative parameterization, widely used for related measurements, they obtain x*{sub +} = 0.11 {+-} 0.06 {+-} 0.02 and x*{sub -} = 0.00 {+-} 0.06 {+-} 0.01. No significant CP-violating charge asymmetry is found in either the flavor-specific mode D {yields} K{sup {+-}}{pi}{sup {-+}} or in B{sup {+-}} {yields} D*{pi}{sup {+-}} decays.

43 PARTICLE ACCELERATORS↗

Automated correction of phase errors in the Advanced Photon Source linac.

Maintaining stable phasing in a linear accelerator is crucial for maintaining optimal performance. If phasing is incorrect, the beam will in general have an energy error and increased energy spread. While an energy error can be readily detected and corrected using position readings from beam position monitors at dispersion locations, this method is not useful for correcting energy spread in a system with many possible phase errors. While energy spread can be corrected by looking at beam size at a dispersive location, this typically involves a beam-intercepting diagnostic and is not compatible with top-up operation. Uncorrected energy spread results in poor capture efficiency in downstream accelerators, such as the Advanced Photon Source (APS) particle accumulator ring or booster synchrotron. To address this issue, APS has implemented beam-to-rf phase detectors in the linac, along with software for automatic correction of phase errors. We discuss the design, implementation, and performance of these detectors, as well as their use in feedback to automatically correct linac phase errors during top-up operation.

43 PARTICLE ACCELERATORS↗

SU-E-T-390: Characterization of the PTW Synthetic Diamond Detector for Radiation Therapy Measurements

Purpose: To investigate the dosimetric properties of new commercially available synthetic single crystal diamond detector under irradiation with therapeutic photon beams from linear accelerators. Methods: A single crystal diamond detector was tested using 6MV photon beam. The detector performance was evaluated for reproducibility, linearity with dose, dose rate dependence, angular dependence, collection efficiency, and measurement of output factors. Lateral field profiles, and percentage depth dose profiles were measured and compared against commercially available detectors. Results: Reproducibility of the detector measurement has a standard deviation of 0.1%. A good linear behavior of the detector response as a function of the delivered dose is observed with deviations below ±0.03% in the dose range from 0.1 to 5Gy. In addition, the detector response is dose rate independent, with deviations below 0.1% in the investigated dose rate range from 1 to 10Gy per min. Charge collection efficiency deviations were within 0.07% from 1 to 10Gy. No angular dependence along the radial direction while up to 1.3% angular dependence was observed in the axial direction. Percentage depth dose curves obtained from the diamond detector are in good agreement with the ones from the reference dosimeters. Lateral beam profile measurements show an overall good agreement among detectors, taking into account their respective geometrical features. The spatial resolution of solid state detectors is confirmed to be better than that of ionization chambers, being the one from the diamond detector comparable to that of the silicon diode. Conclusions: The observed dosimetric properties indicate that the tested diamond detector is a suitable candidate for clinical photon beam dosimetry. The agreement with reference dosimeters show that the detector is suitable for measurements for large fields as well as small fields as the ones used for stereotactic radiotherapy.

60 APPLIED LIFE SCIENCES↗

SU-F-T-379: Dosimetric Impacts of Topical Agents and Dressings On Skin in Radiotherapy

Purpose: This study investigated the superficial dose enhancement in the application of topical agents, clinical materials (thermal mask and bolus) and dressings in megavoltage photon beam radiotherapy. Different topical skin agents, clinical materials and dressings were evaluated and compared for their skin dosimetric impacts on the patients during radiation treatment. Methods: Superficial dose enhancements, or percentage doses with and without the studying materials, were measured using the 6 MV (Field size = 10×10 cm{sup 2}) photon beams produced by a Varian TrueBeam linear accelerator. Twelve topical agents, five dressings (dry and wet conditions) and three clinical materials were studied. A solid water phantom was used with a MOSFET dose detector (TN-1002RD, Thomson and Nielsen Electronic, Ottawa, Ontario, Canada) located under a 1-mm PMMA slab to measure the skin dose. The distance between the radiation source and phantom surface was set to 100 cm in all measurements. The topical agents were distributed evenly with 1.5 mm thickness using our specific sample holder on the phantom surface. Extrapolations were made of 0.5 mm thickness for the agents to provide meaningful clinical value. Results: By comparing surface doses without studying materials, it is found that no topical agents had superficial dose enhancement higher than the clinical materials namely, thermoplastic mask (128%), 5-mm Superflab™ bolus (158%) and 10-mm Superflab™ bolus (171%) regarding the same thickness. Superficial dose enhancement of dry dressing did not exceed 110.5%, while wet dressings produced higher dose enhancements (133% for wet Mepilex lite and 141% for wet Mepilex Ag transfer). Conclusion: It is concluded that the evaluated topical agents and dry dressings did not increase the superficial dose to a concerning level, even using excessive thickness in every fraction of radiation treatment. Wet dressings were found producing the bolus effect, but was still substantially less than applying a thin 5-mm bolus.

43 PARTICLE ACCELERATORS↗

Basis to demonstrate compliance with the National Emission Standards for Hazardous Air Pollutants for the Stand-off Experiments Range

The purpose of this report is to provide the basis and the documentation to demonstrate general compliance with the National Emission Standard for Hazardous Air Pollutants (NESHAPS) 40 CFR 61 Subpart H, “National Emission Standards for Emissions of Radionuclides Other Than Radon from Department of Energy Facilities,” (the Standard) for outdoor linear accelerator operations at the Idaho National Laboratory (INL) Stand-off Experiments Range (SOX). The intent of this report is to inform and gain acceptance of this methodology from the governmental bodies regulating the INL.

43 PARTICLE ACCELERATORS↗