Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Novel technique for spatially resolved imaging of molecular bond orientations using x-ray birefringence

Birefringence has been observed in anisotropic materials transmitting linearly polarized X-ray beams tuned close to an absorption edge of a specific element in the material. Synchrotron bending magnets provide X-ray beams of sufficiently high brightness and cross section for spatially resolved measurements of birefringence. The recently developed X-ray Birefringence Imaging (XBI) technique has been successfully applied for the first time using the versatile test beamline B16 at Diamond Light Source. Orientational distributions of the C–Br bonds of brominated “guest” molecules within crystalline “host” tunnel structures (in thiourea or urea inclusion compounds) have been studied using linearly polarized incident X-rays near the Br K-edge. Imaging of domain structures, changes in C–Br bond orientations associated with order-disorder phase transitions, and the effects of dynamic averaging of C–Br bond orientations have been demonstrated. The XBI setup uses a vertically deflecting high-resolution double-crystal monochromator upstream from the sample and a horizontally deflecting single-crystal polarization analyzer downstream, with a Bragg angle as close as possible to 45°. In this way, the ellipticity and rotation angle of the polarization of the beam transmitted through the sample is measured as in polarizing optical microscopy. The theoretical instrumental background calculated from the elliptical polarization of the bending-magnet X-rays, the imperfect polarization discrimination of the analyzer, and the correlation between vertical position and photon energy introduced by the monochromator agrees well with experimental observations. The background is calculated analytically because the region of X-ray phase space selected by this setup is sampled inefficiently by standard methods.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultra-sensitive high-density Rb-87 radio-frequency magnetometer

Radio-frequency (RF) atomic magnetometers (AMs) can be used in many applications, such as magnetic resonance imaging and nuclear quadrupole resonance. High-density AMs provide both superior sensitivity and large bandwidth. Previously, high-density potassium AMs were demonstrated, but these magnetometers have various disadvantages, such as high-temperature of operation and bulky design. We demonstrate a rubidium-87 RF AM with 5 fT/Hz{sup 1/2} sensitivity (3 fT Hz{sup 1/2} probe noise), which is comparable to that of the best potassium magnetometers. Our magnetometer also features a simple fiber-optic design, providing maximum flexibility for magnetic-field measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pulse-dilation enhanced gated optical imager with 5 ps resolution (invited)

A 5 ps gated framing camera was demonstrated using the pulse-dilation of a drifting electron signal. The pulse-dilation is achieved by accelerating a photoelectron derived information pulse with a time varying potential [R. D. Prosser, J. Phys. E 9, 57 (1976)]. The temporal dependence of the accelerating potential causes a birth time dependent axial velocity dispersion that spreads the pulse as it transits a drift region. The expanded pulse is then imaged with a conventional gated microchannel plate based framing camera and the effective gating time of the combined instrument is reduced over that of the framing camera alone. In the drift region, electron image defocusing in the transverse or image plane is prevented with a large axial magnetic field. Details of the unique issues associated with rf excited photocathodes were investigated numerically and a prototype instrument based on this principle was recently constructed. Temporal resolution of the instrument was measured with a frequency tripled femtosecond laser operating at 266 nm. The system demonstrated 20x temporal magnification and the results are presented here. X-ray image formation strategies and photometric calculations for inertial confinement fusion implosion experiments are also examined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Re-assembly and test of COMB dipole magnet with STAR® wires

Fermilab is developing the Conductor on Molded Barrel (COMB) magnet technology that works well with round REBCO conductors. COMB-STAR-1 magnet based on STAR wire by AMPeers was fabricated and tested in liquid nitrogen in 2023. The magnet demonstrated >90 Ic retention in the coils (before/after winding). Even though the magnet was not originally designed for operation at lower than 77 K temperatures, it was decided to test it in liquid helium to: - check the instrumentation and the DAQ system; - check the ability to detect resistive transitions or quenches and to protect the magnet; - gather the information on possible magnet design chances and upgrades of the test facility for future testing of HTS magnets. The magnet was re-assembled with a larger iron yoke and the axial supports and tested in liquid helium in 2024 at Fermilab s Vertical Magnet Test Facility (VMTF). It was the first HTS magnet test at that facility ever.

Kashikhin, Vadim↗

High Resolution Observations and Modeling of Small-Scale Solar Magnetic Elements

This research contract investigating the radiative transfer and dynamic physics of the smallest observable magnetic structures in the solar photosphere. Due to the lack of a high-resolution visible light satellite instrument for solar studies, all data were acquired using ground-based instrumentation. The primary goal of the investigation was to understand the formation and evolution of "G-band bright points" in relation to the associated magnetic elements. G-band bright points are small (on the order of 100 kin or less in diameter) bright signatures associated with magnetic flux elements in the photosphere. They are seen in the A2A-X2 4308 A molecular bandhead of the CH radical ill the solar spectrum and offer the highest spatial resolution and highest contrast "tracers" of small magnetic structure on the Sun.

Berger, Thomas E.↗

Magnetic Levitators With Superconductive Components

Magnetic noncontact levitators that include superconductive components provide vibration-damping suspension for cryogenic instruments, according to proposal. Because superconductive components attached to levitated cryogenic instruments, no additional coolant liquid or refrigeration power needed. Also because vibration-damping components of levitators located outside cold chambers, in ambient environment, not necessary to waste coolant liquid or refrigeration power on dissipation of vibrational energy. At least three levitating magnets and three superconductors necessary for stable levitation.

Dolgin, Benjamin P.↗

Simultaneous XAFS measurements of multiple samples

A four-channel ionization chamber has been designed, constructed and tested. This ionization chamber allows X-ray absorption spectra to be collected in transmission from up to four samples simultaneously. This results in spectra that are free of systematic uncertainty in relative energy alignment introduced by scan-to-scan stability of the monochromator or of numerical uncertainty associated with a post-processing alignment algorithm, allowing, in a single shot, an absolute measure of edge shift between four samples of different valence. As four samples can be measured in parallel, the time expended over the course of an experiment to cycle the measurement environment between its rest state and the measurement condition is substantially reduced. The ionization chamber is simple in design and could be implemented at virtually any XAFS beamline with a horizontal fan of radiation such as that provided by a bend magnet or wiggler.

47 OTHER INSTRUMENTATION↗

First experimental results on the IShTAR testbed

IShTAR (Ion cyclotron Sheath Test ARrangement) is a linear magnetized plasma test facility dedicated to the investigation of RF wave/plasma interaction [1] in the Ion Cyclotron Range of Frequencies (ICRF). It provides a better accessibility for the instrumentation than tokamaks while being representative of the neighboring region of the wave emitter. It is equipped with a magnetized plasma source (1 m long, 0.4 m diameter) powered by a helical antenna up to 3 kW at 11 MHz. We present the results of the first analysis of the plasma characteristics (plasma density, electron temperature) in function of the operating parameters (injected power, neutral pressure and magnetic field) as measured with fixed and movable Langmuir probes, spectrometer and cameras. The plasma is presently produced only by the helical antenna (no ICRF). We show that the plasma exists in three regime depending on the power level: the first two ones are stable and separated by a jump in density; a first spatial profile of the plasma density has been established for these modes; The third mode is unstable, characterized by strong oscillations of the plasma tube position.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Present Status of the NIMS Contract Beamline BL15XU at SPring-8

The revolver undulator beamline BL15XU at SPring-8, which is the contract beamline of National Institute for Materials Science (NIMS), was established for materials science using soft-and-hard X-ray photoelectron spectroscopy (XPS) and high-resolution powder X-ray diffraction (XRD). We have performed beamline reconstruction for further developments of the experiments in the research field of materials science. The flat double-crystal monochromator (DCM) with liquid nitrogen cooling, X-ray total reflection double-mirror system with (+,-) geometry, and high-energy-resolution channel-cut monochromator have been installed into the beamline. The refined beamline provides monochromatic X-rays from 2 to 36 keV. The improvement of the photon flux density at the XRD and XPS experimental stations was confirmed. The photon flux was estimated to be several 10{sup 12} photons/sec with {Delta}E/E of {approx}10{sup -4}.

43 PARTICLE ACCELERATORS↗

First results and planned experiments with the INFN-LNS ray-tracing magnetic spectrometer MAGNEX

The MAGNEX large-acceptance ray-tracing magnetic spectrometer has recently been used with beams from the INFN-LNS Tandem accelerator. After an accurate commissioning, the instrument has started an ambitious experimental program. In the first experiment the {sup 19}F({sup 7}Li,{sup 7}Be){sup 19}O charge-exchange reaction was studied at 52 MeV incident energy. The {sup 19}O excitation energy spectrum was reconstructed and the angular distributions measured. The second experiment was aimed at the study of the {sup 15}C via the {sup 13}C({sup 18}O,{sup 16}O){sup 15}C reaction at 84 MeV incident energy. The ejectiles where detected at forward angles and mass identified by means of an innovative technique. The {sup 15}C excitation energy spectra up to about 20 MeV were obtained with a 250 keV FWHM energy resolution. In addition to several known states, the spectra show two unknown resonant-like structures at 11.4 and 14.0 MeV. The strong population of these structures, together with the measured widths, could indicate the collective nature of these states associated to a correlated neutron pair transfer. Besides the first results of physical interest from these two experiments, future experiments with MAGNEX are briefly outlined.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electromagnetic Effects in SDF Explosions

The notion of high ion and electron concentrations in the detonation of aluminized explosive mixtures has aroused some interest in electro-magnetic effects that the SDF charges might generate when detonated. Motivated by this interest we have started to investigate whether significant electro-magnetic effects show up in our small-scale experiments. However, the design of instrumentation for this purpose is far from straightforward, since there are a number of open questions. Thus the main aim of the feasibility tests is to find - if possible - a simple and reliable method that can be used as a diagnostic tool for electro-magnetic effects. SDF charges with a 0.5-g PETN booster and a filling of 1 g aluminum flakes have been investigated in three barometric bomb calorimeters with volumes ranging from 6.3 l to of 6.6 l. Though similar in volume, the barometric bombs differed in the length-to-diameter ratio. The tests were carried out with the bombs filled with either air or nitrogen at ambient pressure. The comparison of the test in air to those in nitrogen shows that the combustion of TNT detonation products or aluminum generates a substantial increase of the quasi-steady overpressure in the bombs. Repeated tests in the same configuration resulted in some scatter of the experimental results. The most likely reason is that the aluminum combustion in most or all cases is incomplete and that the amount of aluminum actually burned varies from test to test. The mass fraction burned apparently decreases with increasing aspect ratio L/D. Thus an L/D-ratio of about 1 is optimal for the performance of shock-dispersed-fuel combustion. However, at an L/D-ratio of about 5 the combustion still yields appreciable overpressure in excess of the detonation. For a multi-burst scenario in a tunnel environment with a number of SDF charges distributed along a tunnel section a spacing of 5 tunnel diameter and a fuel-specific volume of around 7 l/g might provide an acceptable compromise between optimizing the combustion performance and keeping the number of elementary charges low. Further tests in a barometric bomb calorimeter of 21.2 l volume were performed with four types of aluminum. The mass fraction burned in this case appeared to depend on the morphology of the aluminum particles. Flake aluminum exhibited a better performance than granulated aluminum with particle sizes ranging from below 25 {micro}m to 125 {micro}m for the coarsest material. In addition, a feasibility study on electro-magnetic effects from SDF charges detonated in a tunnel has been performed. A method was developed to measure the local, unsteady electro-conductivity in the detonation/combustion products cloud. This method proved to yield reproducible results. A variety of methods were tested with regard to probing electro-magnetic pulses from the detonation of SDF charges. The results showed little reproducibility and were small compared to the effect from pulsed high voltage discharges of comparatively small energy (around 32 J). Thus either no significant electromagnetic pulse is generated in our small-scale tests or the tested techniques have to be discarded as too insensitive or too limited in bandwidth to detect possibly very high frequency electro-magnetic disturbances.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optically detected magnetic resonance of nitrogen vacancies in a diamond anvil cell using designer diamond anvils

Optically detected magnetic resonance of nitrogen vacancy centers in diamond offers a route to both DC and AC magnetometry in diamond anvil cells under high pressures (>3 GPa). However, a serious challenge to realizing experiments has been the insertion of microwave radiation into the sample space without screening by the gasket material. We utilize designer anvils with lithographically deposited metallic microchannels on the diamond culet as a microwave antenna. We detected the spin resonance of an ensemble of microdiamonds under pressure and measured the pressure dependence of the zero field splitting parameters. Furthermore, these experiments enable the possibility for all-optical magnetic resonance experiments on nanoliter sample volumes at high pressures.

36 MATERIALS SCIENCE↗

Design of a Large 5 T Superconducting Magnet for Polarized Target for JLAB Hall B 12 GeV Upgrade Clas12 Detector

Hall B at Jefferson Laboratory (JLAB) will need a 5 T, 78 cm bore polarized target magnet with a field uniformity of {Delta}B/B{sub 0} <; 10{sup -4} in a useful cylinder of the dimensions 0.04 m long x 0.02 m in diameter. The large magnet is designed with a superconducting coil that provides the solenoid with nearly perfect self shielding in order to reduce the fringe field at nearby photo multiplier tubes (PMTs) to less than 3.5 mT. Because the solenoid is also very close to the Clas12 Torus, the nearly perfect shielding provided by the self shielded solenoid greatly reduces force, field, and torque interactions with the six-coil Torus magnet. The solenoid coil consists of 18 coil modules which are made of coils mounted in aluminum plate discs. Each coil module consists of dual double pancake coils with main coils and shield coil partitioned into separate winding cavities in the aluminum plate discs to distribute and reduce radial hoop load and radial coil forces. Each coil module is effectively an enclosed aluminum box and this serves to partition the axial load and thus reduces coil axial forces. Since overall coil forces within each coil module are reduced, this will greatly reduce the number coil training quenches. This is a very important consideration for this solenoid coil because the coil cooling is adiabatic, using in-direct conduction cooling by 4.5 K supercritical helium, which will provide only a relatively small temperature stability margin. Super critical helium is used as per JLAB specification. Detail design of the coil structure, coil assembly, cold mass, and cryogenic control will be presented. The magnet protection system shall be capable of the following features: (1) quench and fault detection, (2) fast discharge of the magnet, (3) limit fault voltages to safe values, (4) monitor interlock signals to prevent unsafe operation, and (5) provide control logic necessary for safe operation of the solenoid. The instrument systems shall be capable of the following features: (1) monitors and display temperatures within the solenoid magnet, (2) measure loads or stress on the magnet suspension, (3) monitor voltages within the solenoid magnet and charging bus, (4) monitor pressures and (5) use data logging system to save all sensor data. These systems will be described and a quench analysis presented.

43 PARTICLE ACCELERATORS↗

Triggering for Magnetic Field Measurements of the LCLS Undulators

A triggering system for magnetic field measurements of the LCLS undulators has been built with a National Instruments PXI-1002 and a Xylinx FPGA board. The system generates single triggers at specified positions, regardless of encoder sensor jitter about a linear scale.

43 PARTICLE ACCELERATORS↗

The Mainz high-precision proton form factor measurement

An extensive measurement of the elastic H(e, e')p reaction in the Q{sup 2}-region from 0.003 to 1 (GeV/c){sup 2} has been performed with the 3-spectrometer-setup of the A1 collaboration at the Mainz Microtron. The dataset consists of about 3000 overlapping cross section measurements with a high level of internal redundancy. The large number of precisely measured cross sections allow for a determination of the electric and magnetic form factors with strict control over statistical and systematic errors, in particular also of the charge and magnetization radii of the proton. Besides the classical Rosenbluth separation, the form factors are separated by direct, global fits of different sufficiently flexible models.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Piezomagnetic switching and complex phase equilibria in uranium dioxide

Abstract Actinide materials exhibit strong spin–lattice coupling and electronic correlations, and are predicted to host new emerging ground states. One example is piezomagnetism and magneto-elastic memory effect in the antiferromagnetic Mott-Hubbard insulator uranium dioxide, though its microscopic nature is under debate. Here, we report X-ray diffraction studies of oriented uranium dioxide crystals under strong pulsed magnetic fields. In the antiferromagnetic state a [888] Bragg diffraction peak follows the bulk magnetostriction that expands under magnetic fields. Upon reversal of the field the expansion turns to contraction, before the [888] peak follows the switching effect and piezomagnetic ‘butterfly’ behaviour, characteristic of two structures connected by time reversal symmetry. An unexpected splitting of the [888] peak is observed, indicating the simultaneous presence of time-reversed domains of the 3-k structure and a complex magnetic-field-induced evolution of the microstructure. These findings open the door for a microscopic understanding of the piezomagnetism and magnetic coupling across strong magneto-elastic interactions.

36 MATERIALS SCIENCE↗