Search NASA⌕ Search

SEARCH · Search NASA

Results for “MONITOR PROGRAM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Development and Test of a 1,000 Level 3C Fiber Optic Borehole Seismic Receiver Array Applied to Carbon Sequestration

To address the critical site characterization and monitoring needs for CCS programs, US Department of Energy (DOE) awarded Paulsson, Inc. in 2010 a contract to design, build and test a fiber optic based ultra-large bandwidth clamped borehole seismic vector array capable of deploying up to one thousand 3C sensor pods suitable for deployment into high temperature and high pressure boreholes. Paulsson, Inc. has completed a design or a unique borehole seismic system consisting of a novel drill pipe based deployment system that includes a hydraulic clamping mechanism for the sensor pods, a new sensor pod design and most important – a unique fiber optic seismic vector sensor with technical specifications and capabilities that far exceed the state of the art seismic sensor technologies. These novel technologies were all applied to the new borehole seismic system. In combination these technologies will allow for the deployment of up to 1,000 3C sensor pods in vertical, deviated or horizontal wells. Laboratory tests of the fiber optic seismic vector sensors developed during this project have shown that the new borehole seismic sensor technology is capable of generating outstanding high vector fidelity data with extremely large bandwidth: 0.01 – 6,000 Hz. Field tests have shown that the system can record events at magnitudes much smaller than M-2.3 at frequencies up to 2,000 Hz. The sensors have also proved to be about 100 times more sensitive than the regular coil geophones that are used in borehole seismic systems today. The fiber optic seismic sensors have furthermore been qualified to operate at temperatures over 300°C (572°F). The fibers used for the seismic sensors in the system are used to record Distributed Temperature Sensor (DTS) data allowing additional value added data to be recorded simultaneously with the seismic vector sensor data.

01 COAL, LIGNITE, AND PEAT↗

October 2019 SAPHIRE 8 Software Quality Assurance Oversight Status Report

The software quality assurance oversight consists of updating and maintaining revision control of the System Analysis Program for Hands-on Integrated Reliability Evaluations (SAPHIRE) Version 8 quality assurance program documentation and of monitoring revision control of the SAPHIRE Version 8 source code. This report summarizes the oversight efforts through description of the revision control system (RCS) setup, operation and contents. Documents maintained under revision control include the Acceptance Test Plan (ATP), Configuration Management Plan, Quality Assurance Plan, Software Project Plan, Requirements Traceability Matrix (RTM), System Test Plan, Significance Determination Process (SDP) Interface Training Manual, and the SAPHIRE 8 “New Features and Capabilities Overview.” These documents are referred to and can be transmitted upon request of the Nuclear Regulatory Commission (NRC) Contracting Officer’s Representative (COR).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Visual Examination of Aluminum Containers for Extended Wet Storage of Non-Aluminum-Clad Spent Nuclear Fuel (FY 2021)

The goal of the Augmented Monitoring and Condition Assessment Program (AMCAP) program is to provide a condition assessment of the storage containers for non-aluminum-clad spent nuclear fuel (NASNF) in L Basin and demonstrate continued safe storage of all NASNF pending retrieval for ultimate disposition. The storage configuration of NASNF is vulnerable to inside-out corrosion attack. The approach being used in AMCAP is to develop and deploy examination methods for remote, in-situ inspection of the bundle storage in VTS and for OSC storage in the OSC racks. A method for Visual Examination (VE) using video-recording cameras was readied as part of the full-scale mockup development, and was deployed in L Basin for the initial condition assessment work. This report describes the development and the deployment of the VE for inspection of selected bundles in L Basin. The first deployment of the VE system was for visually examining five spent fuel bundles. Bundles were chosen based on their vulnerability in terms of inner fuel contents, history, storage duration, storage configuration, and possibility of inside out corrosion due to galvanic coupling of fuel cladding with the aluminum bundle wall.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Grays River Watershed Restoration Status Report 2007, May 1, 2007 - October 30, 2008.

The Bonneville Power Administration (BPA) Project 2003-013-00, 'Grays River Watershed Restoration', began in FY04 and continues into FY09. This status report is intended to summarize accomplishments during the period 1 May 2007 through 30 October 2008. Accomplishments are summarized by Work Elements, as detailed in the Statement of Work (see BPA's project management database PISCES). The Pacific Northwest National Laboratory (PNNL) is collaborating with the Columbia River Estuary Task Force (CREST) on implementation of the Grays River Restoration Project. The Grays River is vitally important to the recovery of Lower Columbia River (LCR) chum salmon because it currently has the most viable population remaining in the LCR region. The Grays River watershed is also important to the recovery of salmon and steelhead in the LCR ecosystem. Today, numbers of naturally spawning salmon and steelhead have declined to levels far below historical numbers because of habitat limiting factors that include but are not limited to the lack of habitat connectivity, diversity, channel stability, riparian function and altered stream flow conditions. The objective of this project is to restore habitat-forming processes to enhance salmon and steelhead populations in the Grays River, following recommendations developed during the FY04-06 BPA-sponsored Grays River Watershed Assessment (BPA Project No. 2003-013-00). Specifically, this project will be the first step in restoring channel structure and function that will increase instream habitat diversity, channel stability, and riparian integrity in the critical response reach upstream and adjacent to critical salmon spawning areas of the Grays River. The major component of this strategy is the planning, design, installation, and monitoring of engineered logjams (ELJ) that will rejuvenate historic channel and floodplain processes. Additional restoration measures include reforesting the riparian corridor to enhance future large woody debris recruitment and investigation of conservation activities within ecologically critical areas. These activities include land acquisition and levee removal to protect critical areas and reconnect floodplain areas. Finally, monitoring integrated with restoration activities is proposed to evaluate restoration effectiveness and allow for adaptive management of future restoration treatments in the project area as well as other degraded watersheds in the Lower Columbia River.

13 HYDRO ENERGY↗

Determining the health of Lustre filesystems at scale

Monitoring the components of a Lustre file system is crucial to meeting mission requirements as the scale and complexity of the installation grows. Determining the health and performance of the file system becomes non-trivial, and the complexity increases faster than the size of the installation. This paper discusses the ongoing work at the Oak Ridge Leadership Computing Facility to monitor the health of its center-wide Lustre file systems.

99 GENERAL AND MISCELLANEOUS↗

Sampling and Analysis of the Headspace Gas in 3013 Type Plutonium Storage Containers at Los Alamos National Laboratory

Department of Energy (DOE) sites have packaged approximately 5200 3013 containers to date. One of the requirements specified in DOESTD-3013, which specifies requirements for packaging plutonium bearing materials, is that the material be no greater than 0.5 weight percent moisture. The containers are robust, nested, welded vessels. A shelf life surveillance program was established to monitor these cans over their 50 year design life. In the event pressurization is detected by radiography, it will be necessary to obtain a head space gas sample from the pressurized container. This technique is also useful to study the head space gas in cans selected for random destructive evaluation. The atmosphere is sampled and the hydrogen to oxygen ratio is measured to determine the effects of radiolysis on the moisture in the container. A system capable of penetrating all layers of a 3013 container assembly and obtaining a viable sample of the enclosed gas and an estimate of internal pressure was designed.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Technology Solutions Case Study: Replacement of Variable-Speed Motors for Furnaces

In conjunction with the New York State Energy Research and Development Authority (NYSERDA) and Proctor Engineering Group, Ltd. (PEG), the Consortium for Advanced Residential Buildings (CARB) evaluated the Concept 3™ replacement motors for residential furnaces in eight homes in Syracuse, NY. These brushless, permanent magnet (BPM) motors can use much less electricity than their PSC (permanent split capacitor) predecessors. This evaluation focuses on existing homes in the heating-dominated climate of upstate New York with the goals of characterizing field performance and cost-effectiveness. The results of this study are intended to be useful to home performance contractors, HVAC contractors, and home efficiency program stakeholders. Tests and monitoring was performed both before and after fan motors were replaced. Average fan power reductions were approximately 126 Watts during heating and 220 Watts during cooling operation. Over the course of entire heating and cooling seasons, these translated into average electric energy savings of 163 kWh, with average cost savings of $20 per year. Homes where the fan was used outside of heating and cooling mode saved an additional $42 per year on average. Results indicate that BPM replacement motors will be most cost-effective in HVAC systems with longer run times and relatively low duct static pressures. More dramatic savings are possible if occupants use the fan-only setting when there is no thermal load.

air handler unit↗

Defect Length and Profile Influence on Frequency Domain Reflectometry

Degradation of the cable jacket, electrical insulation, and other cable components of installed cables within nuclear power plants (NPPs) is known to occur as a function of age, temperature, radiation, and other environmental factors. Although system tests verify cable function under normal loads, demonstration of some cable’s ability to perform under exceptional loads associated with design-basis events is essential to assuring plant integrity. The cable’s ability to perform safely over the initial 40 year planned and licensed life has generally been demonstrated and there have been very few age-related cable failures. With greater than 1000 km of power, control, instrumentation, and other cables typically found in an NPP, replacing all the cables would be a severe cost burden. Justification for life extension to 60 and 80 years requires a cable aging management program that includes condition monitoring to justify cable performance under normal operation as well as accident conditions. A variety of tests are available to assess various aspects of electrical and mechanical cable performance, but none are suitable for all cable configurations nor does any single test confirm all features of interest. One particularly promising test that is beginning to be used more and more by utilities is frequency domain reflectometry (FDR). FDR is a nondestructive electrical inspection technique used to detect and localize faults in power and communication system conductors along the length of a cable from a single connection point. FDR detects discontinuities in the electrical impedance that arise due to cable splices or similar changes along the path of the conductor pair. In addition, FDR has the potential to provide sensitivity to insulation degradation by detecting small changes in impedance between the cable conductors being examined. The technique is also sensitive to cable bends, the particular lay of the cable in tray, proximity to other cable, and other factors that bear consideration when interpreting the test results. This paper examines various influences on the FDR approach particularly using FEM modeling methods and focusing on defect length and defect profile.

Cable Inspection, Frequency Domain Reflectometry, ↗

A Retrospective Assessment of Correlation between Occupational and Public Radiation Protection Programs Performance Metrics at a FUSRAP Site - 17546

A retrospective assessment of the occupational and environmental radiation protection programs includes the consideration of performance metrics at the qualitative and quantitative level. When key radiation protection (RP) program metrics are tracked over the course of several years, correlations may present themselves. Strong correlations between variables may be considered when establishing or validating baseline RP Program elements (i.e., controls, monitoring regimes, and additional ALARA measures) for the safe excavation and handling of naturally occurring radioactive materials comingled in soil-like wastes at FUSRAP sites. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Identifying requisite changes to support modern maintenance practices - 294

Modern data science and processing require the use of modern maintenance records. With traditional record-keeping practices, the isolated nature of the data, as well as the presence of handwritten maintenance work orders and incomplete service logs, severely limit the amount of progress that can be made towards advanced condition-based maintenance. These condition-based methods of diagnostics, prognostics, and maintenance planning are a primary goal of next-generation plant operations and maintenance strategies, and are all dependent on the availability of quality plant data including maintenance data. By implementing changes to maintenance record-keeping practices, such as the use of a computerized maintenance management system, key data will become available to allow for implementation of state-of-the-art data analysis methods. This paper covers the benefits of utilizing digital record systems to increase maintenance data availability in terms of condition-based maintenance and asset management. The ability of these methods to enable state-of-the-art practices within industrial organizations is discussed to offer insight into ways that these improvements to operating strategy will contribute to improvements in world-class maintenance excellence. A discussion of the future of asset management in terms of data analytics, maintenance decision support, and data integration is provided to illustrate the changing landscape of plant management. The result is an examination of innovative maintenance strategies and discussion of challenges related to the future of asset management and implementing modern maintenance practices. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Collaborating at a distance: operations centres, tools, and trends

Successful operation of the LHC and its experiments is crucial to the future of the worldwide high-energy physics program. Remote operations and monitoring centres have been established for the CMS experiment in several locations around the world. The development of remote centres began with the LHC{at}FNAL ROC and has evolved into a unified approach with distributed centres that are collectively referred to as 'CMS Centres Worldwide'. An overview of the development of remote centres for CMS will be presented, along with a synopsis of collaborative tools that are used in these centres today and trends in the development of remote operations capabilities for high-energy physics.

99 GENERAL AND MISCELLANEOUS↗

Deploying Server-side File System Monitoring at NERSC

The Franklin Cray XT4 at the NERSC center was equipped with the server-side I/O monitoring infrastructure Cerebro/LMT, which is described here in detail. Insights gained from the data produced include a better understanding of instantaneous data rates during file system testing, file system behavior during regular production time, and long-term average behaviors. Information and insights gleaned from this monitoring support efforts to proactively manage the I/O infrastructure on Franklin. A simple model for I/O transactions is introduced and compared with the 250 million observations sent to the LMT database from August 2008 to February 2009.

97 MATHEMATICS AND COMPUTING↗

Moisture Outgassing Rates from TATB-Formulations: Experiments and Kinetic Model Development

Moisture outgassing rates from materials are of interest and importance to a variety of different fields. Because water can attack and accelerate decomposition, aging, or rusting of various parts, the assembly of an apparatus with 'wet' materials can shorten the lifetime of the apparatus. Outgassing of moisture from materials can be quite slow and a material that is seemingly dry at the time of assembly may slowly release water over years. This slow release of water will compromise the other constituents of the apparatus (e.g. electrical components, metals, organic materials) and shorten the lifetime of the apparatus. For apparatuses that are expensive or laborious to construct, it is especially important to understand and be able to predict the mechanisms and rates of water release from various materials. Such an understanding can support the development of accurate estimates of the apparatus's serviceable age and may allow for mitigation strategies in order to protect other parts from water. Energetic materials such as TATB based PBX-9502 (95% TATB, 5% Kel-F 800) and LX-17 (92.5% TATB and 7.5% Kel-F) pose a particularly challenging problem because they are heterogeneous materials with potentially many different sources and mechanisms of water release. Water molecules could be adsorbed into the polymeric binder matrix, trapped in occlusions within the polymer and the TATB crystals/particles, or trapped within defect sites in the TATB crystal. Finally, many studies indicate that water is a decomposition product under rapid heating conditions, at high temperatures and/or high pressure. Previous studies have measured the water release rate(s) from LX-17 or PBX-9502 prill/powder in order to establish oven drying times prior to use. These studies limited their time frame to a few days or a week of drying. Other studies have looked at the rate of water release of large pressed parts contained in sealed containers. Finally, some studies have looked at the rate of water diffusion through pressed parts, or the effects of wet vs. dry machining, or the influence of the synthesis methods in the amount of water present. There are a few different models that have been developed to predict the rate of water release from LX-17 or PBX-9502. These models are, to some extent, limited by the limitations of the experiments. Because all these experiments looked at water release over a relatively short period of time and left the samples relatively undamaged, they serve as a lower bound. In this work, we perform experiments and develop models that can serve as an upper bound on the rate and amount of water that can be released. Our experimental approach is to use temperature programmed desorption (TPD) and monitor the rate and amount of water release as a function of temperature. We analyzed our experimental data using two different kinetic analysis methods (isoconversional analysis and nth-order Arrhenius kinetic fits) and used the results to make predictions. The suitability of these kinetic analysis methods as well as the applicability of these experiments to long term aging (e.g. years) issues are discussed. Using the kinetics from our experiments, we predict the water release at temperature and timescales relevant to the existing literature. Based on our analysis and comparison with older data, the kinetic model(s) developed in this work serve as a relatively accurate (i.e. order of magnitude) method for predicting the water release under a variety of thermal histories.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ANALYSIS OF EMERGING NDE TECHNIQUES: METHODS FOR EVALUATING AND IMPLEMENTING CONTINUOUS ONLINE MONITORING

One of the goals of the program for the proactive management of materials degradation (PMMD) is to manage proactively the in-service degradation of metallic components in aging NPPs. As some forms of degradation, such as stress corrosion cracking, are characterized by a long initiation time followed by a rapid growth phase, new inspection or monitoring technologies may be required. New nondestructive evaluation (NDE) techniques that may be needed include techniques to find stress corrosion cracking (SCC) precursors, on-line monitoring techniques to detect cracks as they initiate and grow, as well as advances in NDE technologies. This paper reports on the first part of the development of a methodology to determine the effectiveness of these emerging NDE techniques for managing metallic degradation. This methodology will draw from experience derived from evaluating techniques that have "emerged" in the past. The methodology will follow five stages: a definition of inspection parameters, a technical evaluation, laboratory testing, round robin testing, and the design of a performance demonstration program. This methodology will formalize the path taken for previous techniques and set a predictable course for future NDE techniques. This paper then applies the expert review section of the methodology to the acoustic emission technique to evaluate the use of acoustic emission in performing continuous online monitoring of reactor components.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Monitoring the readout temperature in the ICARUS TPC (2023 Italian Students Program Final Report)

Being a Liquid Argon Time Projection Chamber (LAr-TPC) detector, ICARUS exploits a series of three parallel wire planes to measure and collect the ionization charge coming from an event inside the active volume. The wires are read out by A2795 custom boards, arranged in crates located on top of the two liquid Argon vessels. Each board is provided with two temperature sensors that allow temperature monitoring while the experiment is running: this is key in order to ensure data reliability and maintain hardware in safe conditions. Moreover, temperature-related problems may force unplanned shutdowns that result in losing valuable time for the experiment to run. In this work we are discussing the characterization of the ICARUS TPC board temperatures and the system we implemented in order to monitor them effectively. Among the tools used, Grafana results in a valid application for both displaying temperature data and sending alerts to the shifters whenever a pathological situation occurs.

42 ENGINEERING↗

Continuous Monitoring and On-line Analysis of Operational Dose Rates: Tools to Further Mitigate Radiation Risks

Along with passive and active engineering and administrative controls usually implemented in radiation protection programs at different facilities, continuous monitoring and on-line analysis of data measured by the radiation detectors at the workplace and in the environment can be considered as an additional tool used to further mitigate radiation risks. Many monitoring systems on the market today allow connecting radiation area monitors into a network, and reading and accumulating data continuously in a database. The point of this presentation is to bring attention to the fact that such accumulated information can be analyzed and used in many respects to improve reliability and functionality of the monitoring and control systems. A simple time history of background readings from a radiation detector can be used to evaluate the stability of the detector performance. Data recorded during normal facility operations may serve to establish a pattern of acceptable dose rates in such detector and allow to better detect off-normal and unstable modes of the facility operation before they reach hardware trip levels. Facility operators and users may utilize such monitoring systems to optimize operations and minimize their radiological impact. Implementation and examples of use of the RADMON radiation monitoring and data analysis system at Jefferson Lab is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real Time Corrosion Monitoring in Lead and Lead-Bismuth Systems

The objective of this research program is to develop a real-time, in situ corrosion monitoring technique for flowing liquid Pb and eutectic PbBi (LBE) systems in a temperature range of 400 to 650 C. These conditions are relevant to future liquid metal cooled fast reactor operating parameters. THis program was aligned with the Gen IV Reactor initiative to develp technologies to support the design and opertion of a Pb or LBE-cooled fast reactor. The ability to monitor corrosion for protection of structural components is a high priority issue for the safe and prolonged operation of advanced liquid metal fast reactor systems. In those systems, protective oxide layers are intentionally formed and maintained to limit corrosion rates during operation. This program developed a real time, in situ corrosion monitoring tecnique using impedance spectroscopy (IS) technology.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗