Search NASA⌕ Search

SEARCH · Search NASA

Results for “Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Optimal control with accelerated convergence: Combining the Krotov and quasi-Newton methods

One of the most popular methods for solving numerical optimal control problems is the Krotov method, adapted for quantum control by Tannor and coworkers. The Krotov method has the following three appealing properties: (1) monotonic increase of the objective with iteration number, (2) no requirement for a line search, leading to a significant savings over gradient (first-order) methods, and (3) macrosteps at each iteration, resulting in significantly faster growth of the objective at early iterations than in gradient methods where small steps are required. The principal drawback of the Krotov method is slow convergence at later iterations, which is particularly problematic when high fidelity is desired. We show here that, near convergence, the Krotov method degenerates to a first-order gradient method. We then present a variation on the Krotov method that has all the advantages of the original Krotov method but with significantly enhanced convergence (second-order or quasi-Newton) as the optimal solution is approached. We illustrate the method by controlling the three-dimensional dynamics of the valence electron in the Na atom.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development and Validation of Segmentation Method for Lung Cancer Volumetry on Chest CT

The set of criteria called Response Evaluation Criteria In Solid Tumors (RECIST) is used to evaluate the remedial effects of lung cancer, whereby the size of a lesion can be measured in one dimension (diameter). Volumetric evaluation is desirable for estimating the size of a lesion accurately, but there are several constraints and limitations to calculating the volume in clinical trials. In this study, we developed a method to detect lesions automatically, with minimal intervention by the user, and calculate their volume. Our proposed method, called a spherical region-growing method (SPRG), uses segmentation that starts from a seed point set by the user. SPRG is a modification of an existing region-growing method that is based on a sphere instead of pixels. The SPRG method detects lesions while preventing leakage to neighboring tissues, because the sphere is grown, i.e., neighboring voxels are added, only when all the voxels meet the required conditions. In this study, two radiologists segmented lung tumors using a manual method and the proposed method, and the results of both methods were compared. The proposed method showed a high sensitivity of 81.68–84.81% and a high dice similarity coefficient (DSC) of 0.86–0.88 compared with the manual method. In addition, the SPRG intraclass correlation coefficient (ICC) was 0.998 (CI 0.997–0.999, p < 0.01), showing that the SPRG method is highly reliable. If our proposed method is used for segmentation and volumetric measurement of lesions, then objective and accurate results and shorter data analysis time are possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On the efficiency of different numerical methods for the calculation of intrapulse Raman scattering of optical solitons

In this paper we compare the performance of different numerical methods for the calculation of the asymptotic evolution of soliton self-frequency shift in the presence of intrapulse Raman scattering (IRS) in optical fibers. First we have calculated the order of global accuracy for the fundamental soliton and the second-order bound state of the unperturbed nonlinear Schrödinger equation for the following numerical methods: the simple split step (SS) method, the full SS method, the reduced SS method, the reduced SS method with fourth order Runge–Kutta (RK4), the Blow–Wood method, the fourth order Runge–Kutta in the interaction picture (RK4IP) method and the Agrawal SS method with one and two iterations. We have shown that the asymptotic evolution of soliton self-frequency shift in the presence of IRS in optical fiber can be best described by the Agrawal SS method (compared to the Blow–Wood method and the RK4IP method). The obtained numerical results for the soliton position and frequency are in agreement with the predictions for these parameters according to the perturbation theory. We have shown that in the presence of IRS the fundamental soliton quickly develops an oscillating tail on its left. The generated tail hardly influences the soliton propagation at large distances. At large distances the form of the soliton gradually becomes asymmetric. The increase of the frequency resolution leads to a notable increase of the maximum propagation distance of the numerical soliton under the influence of IRS.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development and validation of an automatic method to detect the latest contracting viable left ventricular segments to assist guide CRT therapy from gated SPECT myocardial perfusion imaging

Objectives: The purpose of this study is to use ECG-gated SPECT MPI to detect the latest contracting viable left ventricular (LV) segments to help guide the LV probe placement used in CRT therapy and to validate segment selection against the visual integration method by experts. Methods: For each patient, the resting ECG-gated SPECT MPI short-axis images were sampled in 3D to generate a polar map of the perfusion distribution used to determine LV myocardial viability, and to measure LV synchronicity using our phase analysis tool. In the visual integration method, two experts visually interpreted the LV viability and mechanical dyssynchrony from the short-axis images and polar maps of viability and phase, to determine the latest contracting viable segments using the 17-segment model. In the automatic method, the apical segments, septal segments, and segments with more than 50% scar were excluded as these are not candidates for CRT LV probe placement. Amongst the remaining viable segments, the segments, whose phase angles were within 10° of the latest phase angle (the most delayed contracting segment), were identified for potential CRT LV probe placement and ranked based on the phase angles of the segments. Both methods were tested in 36 pre-CRT patients who underwent ECG-gated SPECT MPI. The accuracy was determined as the percent agreement between the visual integration and automatic methods. The automatic method was performed by a second independent operator to evaluate the inter-operator processing reproducibility. Results: In all the 36 patients, the LV lead positions of the 1st choices recommended by the automatic and visual integration methods were in the same segments in 35 patients, which achieved an agreement rate of 97.2%. In the inter-operator reproducibility test, the LV lead positions of the 1st choices recommended by the two operators were in the same segments in 25 patients, and were in the adjacent segments in 7 patients, which achieved an overall agreement of 88.8%. Conclusions: An automatic method has been developed to detect the latest contracting viable LV segments to help guide the LV probe placement used in CRT therapy. The retrospective clinical study with 36 patients suggests that this method has high agreement against the visual integration method by experts and good inter-operator reproducibility. Consequently, this method is promising to be a clinical tool to recommend the CRT LV lead positions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An automated target species selection method for dynamic adaptive chemistry simulations

The relative importance index (RII) approach for determining appropriate target species for dynamic adaptive chemistry (DAC) simulations using the directed relation graph with error propagation (DRGEP) method is developed. The adequacy and effectiveness of this RII method is validated for two fuels: n-heptane and isopentanol, representatives of a ground transportation fuel component and bio-alcohol, respectively. The conventional method of DRGEP target species selection involves picking an unchanging (static) set of target species based on the combustion processes of interest; however, these static target species may not remain important throughout the entire combustion simulation, adversely affecting the accuracy of the method. In particular, this behavior may significantly reduce the accuracy of the DRGEP-based DAC approach in complex multidimensional simulations where the encountered combustion conditions cannot be known a priori with high certainty. Moreover, testing multiple sets of static target species to ensure the accuracy of the method is generally computationally prohibitive. Instead, the RII method determines appropriate DRGEP target species solely from the local thermo-chemical state of the simulation, ensuring that accuracy will be maintained. Further, the RII method reduces the expertise required of users to select DRGEP target species sets appropriate to the combustion phenomena under consideration. Constant volume autoignition simulations run over a wide range of initial conditions using detailed reaction mechanisms for n-heptane and isopentanol show that the RII method is able to maintain accuracy even when traditional static target species sets fail, and are even more accurate than expert-selected target species sets. Additionally, the accuracy and efficiency of the RII method are compared to those of static target species sets in single-cell engine simulations under homogeneous charge compression ignition conditions. For simulations using more stringent DRGEP thresholds, the RII method performs similarly to that of the static target species sets. With a larger DRGEP threshold, the RII method is significantly more accurate than the static target species sets without imposing significant computational overhead. Moreover, the applicability of the RII method to a DRG-based DAC scheme is discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determination of a suitable molar absorption coefficient (ε) for lignin analysis of fibrous plants using the CASA method

In this study, the benchmarking and applicability of the CASA method for the analysis of fibrous plants, such as flax, hemp, and jute, is evaluated. Lignin is a phenolic biopolymer present in plant cell walls and is composed of three primary monomeric units, designated G, S, and H. Various factors, such as the genetic variability, influence the relative proportions of these units in plant samples. Recently, the cysteine-assisted sulfuric acid (CASA) method has been introduced as a rapid method for the quantification of lignin in wood samples. The aim of this study is to establish a suitable molar absorption coefficient (ε, L·g –1 ·cm –1 ) to adapt the CASA method for use with annual plant fibers. This investigation was motivated by the technical advantages of the CASA method, including higher throughput, lower reaction temperatures, and ecological benefits due to the absence of carcinogenic, mutagenic, or reprotoxic (CMR) substances and the need for minimal sample quantities. In this method, lignin solubilization is facilitated by cysteine, which is an amino acid that enhances the reaction kinetics, using a one-hour incubation period. However, as with any spectrophotometric technique, the CASA method depends on a molar absorption coefficient (ε) that varies according to the ratio of the aromatic units within the polymer. To evaluate the suitability of CASA for quantifying lignin in economically significant plant fibers, we investigate the impact of the unit ratios on the accuracy of ε. The results are compared with those of two widely recognized lignin analytical methods: the Klason method, which is a gravimetric reference method, and the acetyl bromide soluble lignin method, which is the most commonly used spectrophotometric approach. The final ε obtained in this study reveals a relative difference in lignin content ranging from –8 % to +9 % based on a comparison between the CASA and Klason methods across different industrial hemp varieties. As a result, using known G:S ratios in annual fibrous plants, ε can be estimated from our results.

59 BASIC BIOLOGICAL SCIENCES↗

Impact of Statistical Learning Methods on the Predictive Power of Multivariate Normal Tissue Complication Probability Models

Purpose: To study the impact of different statistical learning methods on the prediction performance of multivariate normal tissue complication probability (NTCP) models. Methods and Materials: In this study, three learning methods, stepwise selection, least absolute shrinkage and selection operator (LASSO), and Bayesian model averaging (BMA), were used to build NTCP models of xerostomia following radiotherapy treatment for head and neck cancer. Performance of each learning method was evaluated by a repeated cross-validation scheme in order to obtain a fair comparison among methods. Results: It was found that the LASSO and BMA methods produced models with significantly better predictive power than that of the stepwise selection method. Furthermore, the LASSO method yields an easily interpretable model as the stepwise method does, in contrast to the less intuitive BMA method. Conclusions: The commonly used stepwise selection method, which is simple to execute, may be insufficient for NTCP modeling. The LASSO method is recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Generalized fictitious methods for fluid–structure interactions: Analysis and simulations

We present a new fictitious pressure method for fluid–structure interaction (FSI) problems in incompressible flow by generalizing the fictitious mass and damping methods we published previously in [1]. The fictitious pressure method involves modification of the fluid solver whereas the fictitious mass and damping methods modify the structure solver. We analyze all fictitious methods for simplified problems and obtain explicit expressions for the optimal reduction factor (convergence rate index) at the FSI interface [2]. This analysis also demonstrates an apparent similarity of fictitious methods to the FSI approach based on Robin boundary conditions, which have been found to be very effective in FSI problems. We implement all methods, including the semi-implicit Robin based coupling method, in the context of spectral element discretization, which is more sensitive to temporal instabilities than low-order methods. However, the methods we present here are simple and general, and hence applicable to FSI based on any other spatial discretization. In numerical tests, we verify the selection of optimal values for the fictitious parameters for simplified problems and for vortex-induced vibrations (VIV) even at zero mass ratio (“for-ever-resonance”). We also develop an empirical a posteriori analysis for complex geometries and apply it to 3D patient-specific flexible brain arteries with aneurysms for very large deformations. We demonstrate that the fictitious pressure method enhances stability and convergence, and is comparable or better in most cases to the Robin approach or the other fictitious methods.

Computer Science↗

Hermite WENO limiting for multi-moment finite-volume methods using the ADER-DT time discretization for 1-D systems of conservation laws

New Hermite Weighted Essentially Non-Oscillatory (HWENO) interpolants are developed and investigated within the Multi-Moment Finite-Volume (MMFV) formulation using the ADER-DT time discretization. Whereas traditional WENO methods interpolate pointwise, function-based WENO methods explicitly form a non-oscillatory, high-order polynomial over the cell in question. This study chooses a function-based approach and details how fast convergence to optimal weights for smooth flow is ensured. Methods of sixth-, eighth-, and tenth-order accuracy are developed. We compare these against traditional single-moment WENO methods of fifth-, seventh-, ninth-, and eleventh-order accuracy to compare against more familiar methods from literature. The new HWENO methods improve upon existing HWENO methods (1) by giving a better resolution of unreinforced contact discontinuities and (2) by only needing a single HWENO polynomial to update both the cell mean value and cell mean derivative. Test cases to validate and assess these methods include 1-D linear transport, the 1-D inviscid Burger's equation, and the 1-D inviscid Euler equations. Smooth and non-smooth flows are used for evaluation. These HWENO methods performed better than comparable literature-standard WENO methods for all regimes of discontinuity and smoothness in all tests herein. They exhibit improved optimal accuracy due to the use of derivatives, and they collapse to solutions similar to typical WENO methods when limiting is required. The study concludes that the new HWENO methods are robust and effective when used in the ADER-DT MMFV framework. Finally, these results are intended to demonstrate capability rather than exhaust all possible implementations.

97 MATHEMATICS AND COMPUTING↗

A physical method for downscaling land surface temperatures using surface energy balance theory

Fine-resolution land surface temperature (LST) derived from thermal infrared remote sensing images is a good indicator of surface water status and plays an essential role in the exchange of energy and water between land and atmosphere. A physical surface energy balance (SEB)-based LST downscaling method (DTsEB) is developed to downscale coarse remotely sensed thermal infrared LST products with fine-resolution visible and near-infrared data. Here, the DTsEB method is advantageous for its ability to mechanically interrelate surface variables contributing to the spatial variation of LST, to quantitatively weigh the contributions of each related variable within a physical framework, and to efficaciously avoid the subjective selection of scaling factors and the establishment of statistical regression relationships. The applicability of the DTsEB method was tested by downscaling 12 scenes of 990 m Moderate Resolution Imaging Spectroradiometer (MODIS) and aggregated Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) LST products to 90 m resolution at six overpass times between 2005 and 2015 over three 9.9 km by 9.9 km cropland (mixed by grass, tree, and built-up land) study areas. Three typical LST downscaling methods, namely the widely applied TsHARP, the later developed least median square regression downscaling (LMS) and the geographically weighted regression (GWR), were introduced for intercomparison. The results showed that the DTsEB method could more effectively reconstruct the subpixel spatial variations in LST within the coarse-resolution pixels and achieve a better downscaling accuracy than the TsHARP, LMS and GWR methods. The DTsEB method yielded, on average, root mean square errors (RMSEs) of 2.01 K and 1.42 K when applied to the MODIS datasets and aggregated ASTER datasets, respectively, which were lower than those obtained with the TsHARP method, with average RMSEs of 2.41 K and 1.71 K, the LMS method, with average RMSEs of 2.35 K and 1.63 K, and the GWR method, with average RMSEs of 2.38 K and 1.64 K, respectively. The contributions of the related surface variables to the subpixel spatial variation in the LST varied both spatially and temporally and were different from each other. In summary, the DTsEB method was demonstrated to outperform the TsHARP, LMS, and GWR methods and could be used as a good alternative for downscaling LST products from coarse to fine resolution with high robustness and accuracy.

54 ENVIRONMENTAL SCIENCES↗

Incorporating a completely renormalized coupled cluster approach into a composite method for thermodynamic properties and reaction paths

The correlation consistent composite approach (ccCA), using the S4 complete basis set two-point extrapolation scheme (ccCA-S4), has been modified to incorporate the left-eigenstate completely renormalized coupled cluster method, including singles, doubles, and non-iterative triples (CR-CC(2,3)) as the highest level component. The new ccCA-CC(2,3) method predicts thermodynamic properties with an accuracy that is similar to that of the original ccCA-S4 method. At the same time, the inclusion of the single-reference CR-CC(2,3) approach provides a ccCA scheme that can correctly treat reaction pathways that contain certain classes of multi-reference species such as diradicals, which would normally need to be treated by more computationally demanding multi-reference methods. The new ccCA-CC(2,3) method produces a mean absolute deviation of 1.7 kcal/mol for predicted heats of formation at 298 K, based on calibration with the G2/97 set of 148 molecules, which is comparable to that of 1.0 kcal/mol obtained using the ccCA-S4 method, while significantly improving the performance of the ccCA-S4 approach in calculations involving more demanding radical and diradical species. Both the ccCA-CC(2,3) and ccCA-S4 composite methods are used to characterize the conrotatory and disrotatory isomerization pathways of bicyclo[1.1.0]butane to trans-1,3-butadiene, for which conventional coupled cluster methods, such as the CCSD(T) approach used in the ccCA-S4 model and, in consequence, the ccCA-S4 method itself might fail by incorrectly placing the disrotatory pathway below the conrotatory one. The ccCA-CC(2,3) scheme provides correct pathway ordering while providing an accurate description of the activation and reaction energies characterizing the lowest-energy conrotatory pathway. The ccCA-CC(2,3) method is thus a viable method for the analyses of reaction mechanisms that have significant multi-reference character, and presents a generally less computationally intensive alternative to true multi-reference methods, with computer costs and ease of use that are similar to those that characterize the more established, CCSD(T)-based, ccCA-S4 methodology.

36 MATERIALS SCIENCE↗

A comparison of methods for melting point calculation using molecular dynamics simulations

Accurate and efficient prediction of melting points for complex molecules is still a challenging task for molecular simulation, although many methods have been developed. Four melting point computational methods, including one free energy-based method (the pseudo-supercritical path (PSCP) method) and three direct methods (two interface-based methods and the voids method) were applied to argon and a widely studied ionic liquid 1-n-butyl-3-methylimidazolium chloride ([BMIM][Cl]). The performance of each method was compared systematically. All the methods under study reproduce the argon experimental melting point with reasonable accuracy. For [BMIM][Cl], the melting point was computed to be 320 K using a revised PSCP procedure, which agrees with the experimental value 337-339 K very well. However, large errors were observed in the computed results using the direct methods, suggesting that these methods are inappropriate for large molecules with sluggish dynamics. The strengths and weaknesses of each method are discussed. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.3702587]

Zhang, Y↗

Automated property optimization via ab initio O(N) elongation method: Application to (hyper-)polarizability in DNA

An automated property optimization method was developed based on the ab initio O(N) elongation (ELG) method and applied to the optimization of nonlinear optical (NLO) properties in DNA as a first test. The ELG method mimics a polymerization reaction on a computer, and the reaction terminal of a starting cluster is attacked by monomers sequentially to elongate the electronic structure of the system by solving in each step a limited space including the terminal (localized molecular orbitals at the terminal) and monomer. The ELG-finite field (ELG-FF) method for calculating (hyper-)polarizabilities was used as the engine program of the optimization method, and it was found to show linear scaling efficiency while maintaining high computational accuracy for a random sequenced DNA model. Furthermore, the self-consistent field convergence was significantly improved by using the ELG-FF method compared with a conventional method, and it can lead to more feasible NLO property values in the FF treatment. The automated optimization method successfully chose an appropriate base pair from four base pairs (A, T, G, and C) for each elongation step according to an evaluation function. From test optimizations for the first order hyper-polarizability (β) in DNA, a substantial difference was observed depending on optimization conditions between “choose-maximum” (choose a base pair giving the maximum β for each step) and “choose-minimum” (choose a base pair giving the minimum β). In contrast, there was an ambiguous difference between these conditions for optimizing the second order hyper-polarizability (γ) because of the small absolute value of γ and the limitation of numerical differential calculations in the FF method. It can be concluded that the ab initio level property optimization method introduced here can be an effective step towards an advanced computer aided material design method as long as the numerical limitation of the FF method is taken into account.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Explicit Integration of Extremely Stiff Reaction Networks: Quasi-Steady-State Methods

A preceding paper [1] demonstrated that explicit asymptotic methods generally work much better for extremely stiff reaction networks than has previously been shown in the literature. There we showed that for systems well removed from equilibrium explicit asymptotic methods can rival standard implicit codes in speed and accuracy for solving extremely stiff differential equations. In this paper we continue the investigation of systems well removed from equilibrium by examining quasi-steady-state (QSS) methods as an alternative to asymptotic methods. We show that for systems well removed from equilibrium, QSS methods also can compete with, or even exceed, standard implicit methods, even for extremely stiff networks, and in many cases give somewhat better integration speed than for asymptotic methods. As for asymptotic methods, we will find that QSS methods give correct results, but with non-competitive integration speed as equilibrium is approached. Thus, we shall find that both asymptotic and QSS methods must be supplemented with partial equilibrium methods as equilibrium is approached to remain competitive with implicit methods.

Guidry, Mike W↗

Quantification of uncertainties in thermoelectric properties of materials from a first-principles prediction method: An approach based on Gaussian process regression

We present the electron-phonon averaged via Gaussian process regression (EPA-GPR) method, in which the electron-phonon coupling matrix is represented as a function of two energies and is in turn modeled as a Gaussian process. The EPA-GPR method can be used as an efficient method to estimate thermoelectric properties of materials for fast-screening applications, comparable to the original electron-phonon averaged (EPA) method and the electron-phonon averaged via moving-least-squares (EPA-MLS) method. The EPA-GPR method does not require specification of any open parameter, unlike the other EPA-related methods, since all the hyperparameters in the model can be unambiguously estimated within the type II maximum likelihood (ML-II) approximation. Thus, the EPA-GPR method is a parameter-free estimation method. Additionally, the concept of Gaussian processes in the EPA-GPR method allows us to quantify the uncertainty in estimated properties of thermoelectric materials. One can randomly realize the electron-phonon coupling coefficients from the identified Gaussian process, and those realized samples can be further analyzed in the solution process of the semiclassical Boltzmann transport equation for charge carriers. The results of the semiclassical Boltzmann transport equation provide the statistical properties of the thermoelectric properties of interest. The means, standard deviations, histograms, and confidence intervals of the Seebeck coefficient, the electrical conductivity, and the power factor can be constructed and analyzed. Furthermore the proposed EPA-GPR method is applied to a p-type half-Heusler compound, i.e., HfCoSb, as a case example, the results of which clearly present the advantages of the method.

30 DIRECT ENERGY CONVERSION↗

Evaluation of a method for activity estimation in Sm-153 EDTMP imaging

Absolute activity evaluation is fundamental for internal radionuclide dosimetry when patient-specific therapy optimization is wanted. Often, quantification is attempted with 3D SPECT image based (IB) methods, but the true concentration values can be underestimated due to the partial volume effect (PVE). This is especially true when small diffuse lesions are present. In this paper, we describe a 3D region of interest (ROI) based quantification method (LS-ROI), which estimates the ROI concentration values directly from the projection data acquired in the tomographic scan once ROIs have been segmented on a CT and/or a SPECT image. The method, which has inherent PVE correction capabilities, was applied both on simulated and on real phantom data. Simulations reflected the case of a patient with bone metastases treated with {sup 153}Sm-EDTMP: Both the activity in the metastases and the total retention in the skeleton were evaluated. Thirty noisy data sets were produced in order to evaluate the accuracy and precision of the method. The effect of region segmentation errors on estimated concentrations was thoroughly investigated. Real data were acquired on a NEMA phantom, where a cylindrical central region (283 cm{sup 3}) simulated the bone and two spheres (10.3 and 25.5 cm{sup 3}) simulated the metastases. The results obtained with the LS-ROI method were compared with those of a conventional 3D IB method and those of a quantitative conjugate view approach derived from LS-ROI and applied to the anterior and posterior views acquired in the tomographic scan (LS-ROI anterior-posterior: LS-ROI-AP). Simulations showed that when the geometry of regions is known, the LS-ROI method recovered the simulated concentration values within 20%, while the IB method underestimated the concentration in high activity small lesions by as much as 49%. Segmentation errors, up to 44% of the true region volume, produced a higher variation in LS-ROI estimates than in IB ones; however, the overall bias of the LS-ROI estimates ({<=}25%) remained lower than that of IB estimates. In the case of the evaluation of the total retention in the skeleton, the LS-ROI method recovered the simulated value within 2%, while IB underestimated it up to 13%. In all the cases, the LS-ROI-AP method showed an accuracy comparable with that of the LS-ROI one, and a worse precision just because of the lower number of counts used in the analysis. However, a worsening of LS-ROI-AP performances was demonstrated in the case of strong overlap of regions: In this case, a bias of up to 40% was observed. The results obtained on real phantom data confirmed the simulation results: The IB method underestimated activity up to 47% in the smallest sphere, while the bias was reduced to 13% with LS-ROI and LS-ROI-AP estimates. The good quantification capabilities of the LS-ROI method can be useful for absolute activity quantification in the case of small active diffused lesions and constitute the basis for the development of an accurate patient-specific planning strategy in internal radionuclide treatments, provided there is a reliable segmentation of lesions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A method for patient dose reduction in dynamic contrast enhanced CT study

Purpose: In dynamic contrast enhanced CT (DCE-CT) study, prolonged CT scanning with high temporal resolution is required to give accurate and precise estimates of kinetic parameters. However, such scanning protocol could lead to substantial radiation dose to the patient. A novel method is proposed to reduce radiation dose to patient, while maintaining high accuracy for kinetic parameter estimates in DCE-CT study. Methods: The method is based on a previous investigation that the arterial impulse response (AIR) in DCE-CT study can be predicted using a population-based scheme. In the proposed method, DCE-CT scanning is performed with relatively low temporal resolution, hence, giving rise to reduction in patient dose. A novel method is proposed to estimate the arterial input function (AIF) based on the coarsely sampled AIF. By using the estimated AIF in the tracer kinetic analysis of the coarsely sampled DCE-CT study, the calculated kinetic parameters are able to achieve a high degree of accuracy. The method was tested on a DCE-CT data set of 48 patients with cervical cancer scanned at high temporal resolution. A random cohort of 34 patients was chosen to construct the orthonormal bases of the AIRs via singular value decomposition method. The determined set of orthonormal bases was used to fit the AIFs in the second cohort (14 patients) at varying levels of down sampling. For each dataset in the second cohort, the estimated AIF was used for kinetic analyses of the modified Tofts and adiabatic tissue homogeneity models for each of the down-sampling schemes between intervals from 2 to 15 s. The results were compared with analyses done with the ''raw'' down-sampled AIF. Results: In the first group of 34 patients, there were 11 orthonormal bases identified to describe the AIRs. The AIFs in the second group were estimated in high accuracy based on the 11 orthonormal bases established in the first group along with down-sampled AIFs. Using the 11 orthonormal bases, the estimated AIFs for the second group were found to have an averaged maximal percentage error of 3.4%{+-} 7.5% in all sampling schemes up to 15 s. The results of kinetic analysis with the proposed method compared with down sampling alone showed that the proposed method is superior in maintaining the accuracy in volume transfer constant (K{sup trans} ) after 9 s down-sampling interval, blood volume (v{sub b} ) for almost all down-sampling intervals, and blood flow (F) after 11 s down-sampling interval. The preliminary results suggested that the proposed method is able to support scanning intervals of 10-15 s at a cost of 6.2%-10.0% loss in accuracy of K{sup trans} and 10.9%-19.4% in v{sub b}, and the scanning intervals of 12-15 s at a cost of 9.7%-14.6% for F in DEC-CT studies for patients with cervix cancer. Conclusions: The proposed method of AIF estimation allows low scanning frequency in DCE-CT study to reduce radiation dose to patient, while maintaining relatively high accuracy in the kinetic parameter estimates. The initial results suggested that the method is applicable for DCE-CT studies for patients with cervical cancer.

60 APPLIED LIFE SCIENCES↗

A method for removing arm backscatter from EPID images

Purpose: To develop a method for removing the support arm backscatter from images acquired using current Varian electronic portal imaging devices (EPIDs).Methods: The effect of arm backscatter on EPID images was modeled using a kernel convolution method. The parameters of the model were optimized by comparing on-arm images to off-arm images. The model was used to develop a method to remove the effect of backscatter from measured EPID images. The performance of the backscatter removal method was tested by comparing backscatter corrected on-arm images to measured off-arm images for 17 rectangular fields of different sizes and locations on the imager. The method was also tested using on- and off-arm images from 42 intensity modulated radiotherapy (IMRT) fields.Results: Images generated by the backscatter removal method gave consistently better agreement with off-arm images than images without backscatter correction. For the 17 rectangular fields studied, the root mean square difference of in-plane profiles compared to off-arm profiles was reduced from 1.19% (standard deviation 0.59%) on average without backscatter removal to 0.38% (standard deviation 0.18%) when using the backscatter removal method. When comparing to the off-arm images from the 42 IMRT fields, the mean {gamma} and percentage of pixels with {gamma} < 1 were improved by the backscatter removal method in all but one of the images studied. The mean {gamma} value (1%, 1 mm) for the IMRT fields studied was reduced from 0.80 to 0.57 by using the backscatter removal method, while the mean {gamma} pass rate was increased from 72.2% to 84.6%.Conclusions: A backscatter removal method has been developed to estimate the image acquired by the EPID without any arm backscatter from an image acquired in the presence of arm backscatter. The method has been shown to produce consistently reliable results for a wide range of field sizes and jaw configurations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗