Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operating Experience”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

JLAB LLRF 3.0 Development and Tests

The Jefferson Lab LLRF 3.0 system is being developed to replace legacy LLRF systems in the CEBAF accelerator. The new design builds upon 25 years of design and operational RF control experience, and our recent collaboration in the design of the LCLSII LLRF system. The new cavity control algorithm is a fully functional phase and amplitude locked Self Exciting Loop (SEL). This paper discusses the progress of the LLRF 3.0 hardware design, FPGA firmware development, User Datagram Protocol (UDP) operation, and recent LLRF 3.0 system tests on the CEBAF Booster cryomodule in the Upgrade Injector Test Facility (UITF).

Plawski, T. E.↗

Implementation of the MPC and A Operations Monitorying (MOM) System at JSC PO Sevmas

The Material Protection, Control and Accounting (MPC&A) Program has been working since 1994 with nuclear sites in Russia to upgrade the physical protection (PP) and material control and accounting (MC&A) functions at facilities containing weapons usable nuclear material. In early 2001, the MPC&A program initiated the MPC&A Operations Monitoring (MOM) Project to monitor facilities where MPC&A upgrades have been installed to provide increased confidence that personnel are present and vigilant, provide confidence that security procedures are being properly performed and provide additional assurance that nuclear materials have not been stolen. The MOM project began as a pilot project at the Moscow State Engineering Physics Institute (MEPhI) and a MOM system was successfully installed in October 2001. Following the success of the MEPhI pilot project, the MPC&A Program expanded the installation of MOM systems to several other Russian facilities, including the JSC 'PO' Sevmash', Severodvinsk, Russia. The MOM system was made operational at Sevmash in September, 2008. This paper will discuss the objectives of the MOM system installed at Sevmash and indicate how the objectives influenced the development of the conceptual design. The paper will also describe activities related to installation of the infrastructure and the MOM system at Sevmash. Experience gained from operation of the system and how the objectives are being met will also be discussed. The paper will describe how the MOM system is used at Sevmash and, in particular, how the data is analyzed. Finally, future activities including potential expansion of the MOM system, operator training, data sharing and analysis, procedure development, repair and maintenance will be included in the paper.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Aerosol and Cloud Experiments in the Eastern North Atlantic (ACE-ENA) Winter Intensive Operational Period: Aerodynamic Particle Sizer Field Campaign Report

An aerodynamic particle sizer spectrometer (APS, model 3321 by TSI Inc., Shoreview, Minnesota) was deployed at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility Eastern North Atlantic (ENA) observatory during the second (winter) intensive operational period (IOP) of the Aerosol and Cloud Experiments in the Eastern North Atlantic (ACE-ENA) field campaign. Data were collected from January 9 through February 26, 2018, covering the second deployment of the ARM Aerial Facility (AAF) aircraft within ACE-ENA. The standard ENA instrument suite does not provide measurements of aerosol particle size distribution for diameters greater than one micron. Properties of coarse-mode (super-micron) aerosols are rarely measured, although super-micron particles can play an important role in the aerosol life cycle, affecting aerosol optical properties and cloud nuclei activity (e.g., Clarke et al. 2003). The APS was deployed to fill this gap in particle size measurements: it is capable of measuring size-resolved concentration of the aerosols in the 0.5-20 μm range (aerodynamic diameter). The APS was installed in the aerosol trailer to sample through the main stack. Special attention was given to selection of the instrument location (just below the main stack) to minimize particle losses in the connecting lines. Most atmospheric aerosols are hygroscopic, so the measurement of the aerosol size distributions should either be performed in a controlled humidity environment or accompanied by concurrent measurement of the temperature and humidity of the sample air. The latter strategy was used during this deployment: a high-precision humidity/temperature transmitter (model EE08 by E+E Elektonik GMBH, Engerwitzdorf, Germany) was mounted in the APS sampling line immediately upstream of the APS inlet. A dedicated laptop computer was used for data collection and communications. The APS was controlled with vendor-supplied software (Aerosol Instrument Manager, ver. 10.1, TSI); aerosol size distribution data were collected over a period of 55 seconds and converted to one-minute averages. Temperature and humidity analog signals were acquired via analog-to-digital converter (ADC) module (model WTAIN-M by Weeder Technologies, Fort Walton Beach, Florida) using vendor-supplied software (ModCom) with 1- sec resolution. In post-processing, the APS data were exported from TSI proprietary format into “comma-separated value” American Standard Code for Information Interchange (ASCII) files and matched with appropriately averaged temperature and humidity data. Two significant periods of missing data were caused by local power outages. Vendor-supplied software was not designed for unattended operation: it needs to be manually restarted including sensor configuration setup.

ACE-ENA, Azores, ultra-high-sensitivity aerosol sp↗

Evaluating the Effects of Transient Purge Flow on Stator-Rotor Seal Performance

Abstract As modern engine designs target higher efficiencies through increased turbine inlet temperatures, critical turbine components are at increased risk of damage from conditions exceeding material melting temperatures. In particular, improperly designed underplatform hardware components are susceptible to damage when hot main gas path flow is ingested into the stator-rotor cavity. While all turbines inherently experience transients during operation, a majority of publicly available turbine studies have been executed using steady operating conditions or inherently transient “blowdown” rigs. For this reason, routine transient events are not well understood. To address this need, the present study utilized a combined experimental and computational approach. The test article is a continuous-duration, one-stage test turbine operating with true-scale engine hardware and seal geometries at engine-representative flow conditions. The nature of the continuous-duration facility uniquely supports the direct assessment of transient events through its ability to transition between steady-state operating conditions. The effects of a transient purge flow were investigated in this study to identify general trends for transient events in a full-scale engine. Results from multiple measurement techniques in the wheelspace region show an interdependence of transient purge flow with a thermal lag of the underplatform hardware. Through experiments conducted at different coolant-to-main gas path temperature ratios, the use of pressure measurements as an indicator of fully purged behavior was introduced, and a thermally driven influence on rim seal performance was quantified. The computational results show good agreement with experimental pressure measurements and provide insight into the physical mechanisms that drive the relationship between pressure and sealing effectiveness measurements observed for the tested geometry.

Engineering↗

Non-intrusive data-driven model reduction for differential–algebraic equations derived from lifting transformations

In this paper we present a non-intrusive data-driven approach for model reduction of nonlinear systems. The approach considers the particular case of nonlinear partial differential equations (PDEs) that form systems of partial differential–algebraic equations (PDAEs) when lifted to polynomial form. Such systems arise, for example, when the governing equations include Arrhenius reaction terms (e.g., in reacting flow models) and thermodynamic terms (e.g., the Helmholtz free energy terms in a phase-field solidification model). Using the known structured form of the lifted algebraic equations, the approach computes the reduced operators for the algebraic equations explicitly, using straightforward linear algebra operations on the basis matrices. The reduced operators for the differential equations are inferred from lifted snapshot data using operator inference, which solves a linear least squares regression problem. The approach is illustrated for the nonlinear model of solidification of a pure material. The lifting transformations reformulate the solidification PDEs as a system of PDAEs that have cubic structure. The operators of the lifted system for this solidification example have affine dependence on key process parameters, permitting us to learn a parametric reduced model with operator inference. Numerical experiments show the effectiveness of the resulting reduced models in capturing key aspects of the solidification dynamics.

42 ENGINEERING↗

Modeling of the SPERT Transients Using SERPENT2 with Time Dependent Capabilities

Over the last decade, multiphysics coupled calculations have become one of the most important research topics in the area of development and enhancement of reactor analysis and simulation tools. One of the main applications of these coupled simulations is transient analysis, which may involve modeling of experiments, normal plant operation or accident scenarios. Traditionally, the reactor physics side of coupled simulations has been represented by deterministic or hybrid Monte Carlo - deterministic methods. Monte Carlo techniques are limited by their high computational cost. However increased computing power makes their application to multiphysics modeling of transients feasible. Active research is underway to develop algorithms for time dependent calculations, implement them in Monte Carlo codes, and evaluate their performance. In this paper time dependent simulations of the SPERT experiments using the Serpent2 code are presented.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Overview of the results from divertor experiments with attached and detached plasmas at Wendelstein 7-X and their implications for steady-state operation

Abstract Wendelstein 7-X (W7-X), the largest advanced stellarator, is built to demonstrate high power, high performance quasi-continuous operation. Therefore, in the recent campaign, experiments were performed to prepare for long pulse operation, addressing three critical issues: the development of stable detachment, control of the heat and particle exhaust, and the impact of leading edges on plasma performance. The heat and particle exhaust in W7-X is realized with the help of an island divertor, which utilizes large magnetic islands at the plasma boundary. This concept shows very efficient heat flux spreading and favourable scaling with input power. Experiments performed to overload leading edges showed that the island divertor yields good impurity screening. A highlight of the recent campaign was a robust detachment scenario, which allowed reducing power loads even by a factor of ten. At the same time, neutral pressures at the pumping gap entrance yielded the particle removal rate close to the values required for stable density control in steady-state operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High fusion performance in Super H-mode experiments on Alcator C-Mod and DIII-D

The ‘Super H-Mode’ regime is predicted to enable pedestal height and fusion performance substantially higher than standard H-Mode operation. This regime exists due to a bifurcation of the pedestal pressure, as a function of density, that is predicted by the EPED model to occur in strongly shaped plasmas above a critical pedestal density. Experiments on Alcator C-Mod and DIII-D have achieved access to the Super H-Mode (and Near Super H) regime, and obtained very high pedestal pressure, including the highest achieved on a tokamak (pped ~ 80 kPa) in C-Mod experiments operating near the ITER magnetic field. DIII-D Super H experiments have demonstrated strong performance, including the highest stored energy in the present configuration of DIII-D (W ~ 2.2–3.2 MJ), while utilizing only about half of the available heating power (Pheat ~ 7–12 MW). These DIII-D experiments have obtained the highest value of peak fusion gain, QDT,equiv ~ 0.5, achieved on a medium scale (R < 2 m) tokamak. Sustained high performance operation (βN ~ 2.9, H98 ~ 1.6) has been achieved utilizing n = 3 magnetic perturbations for density and impurity control. Pedestal and global confinement has been maintained in the presence of deuterium and nitrogen gas puffing, which enables a more radiative divertor condition. A pair of simple performance metrics is developed to assess and compare regimes. Super H-Mode access is predicted for ITER and expected, based on both theoretical prediction and observed normalized performance, to allow ITER to achieve its goals (Q = 10) at Ip < 15 MA, and to potentially enable more compact, cost effective pilot plant and reactor designs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A new cryogenic apparatus to search for the neutron electric dipole moment

A cryogenic apparatus is described that enables a new experiment, nEDM@SNS, with a major improvement in sensitivity compared to the existing limit in the search for a neutron Electric Dipole Moment (EDM). This apparatus uses superfluid 4 He to produce a high density of Ultra-Cold Neutrons (UCN) which are contained in a suitably coated pair of measurement cells. The experiment, to be operated at the Spallation Neutron Source at Oak Ridge National Laboratory, uses polarized 3 He from an Atomic Beam Source injected into the superfluid 4 He and transported to the measurement cells where it serves as a co-magnetometer. The superfluid 4 He is also used as an insulating medium allowing significantly higher electric fields, compared to previous experiments, to be maintained across the measurement cells. Finally, these features provide an ultimate statistical uncertainty for the EDM of 2-3× 10 -28 e-cm, with anticipated systematic uncertainties below this level.

47 OTHER INSTRUMENTATION↗

AVESTAR Center for Operational Excellence of Electricity Generation Plants

To address industry challenges in attaining operational excellence for electricity generation plants, the U.S. Department of Energy’s (DOE) National Energy Technology Laboratory (NETL) has launched a world-class facility for Advanced Virtual Energy Simulation Training and Research (AVESTARTM). This presentation will highlight the AVESTARTM Center simulators, facilities, and comprehensive training, education, and research programs focused on the operation and control of high-efficiency, near-zero-emission electricity generation plants. The AVESTAR Center brings together state-of-the-art, real-time, high-fidelity dynamic simulators with full-scope operator training systems (OTSs) and 3D virtual immersive training systems (ITSs) into an integrated energy plant and control room environment. AVESTAR’s initial offering combines--for the first time--a “gasification with CO2 capture” process simulator with a “combined-cycle” power simulator together in a single OTS/ITS solution for an integrated gasification combined cycle (IGCC) power plant with carbon dioxide (CO2) capture. IGCC systems are an attractive technology option for power generation, especially when capturing and storing CO2 is necessary to satisfy emission targets. The AVESTAR training program offers a variety of courses that merge classroom learning, simulator-based OTS learning in a control-room operations environment, and immersive learning in the interactive 3D virtual plant environment or ITS. All of the courses introduce trainees to base-load plant operation, control, startups, and shutdowns. Advanced courses require participants to become familiar with coordinated control, fuel switching, power-demand load shedding, and load following, as well as to problem solve equipment and process malfunctions. Designed to ensure work force development, training is offered for control room and plant field operators, as well as engineers and managers. Such comprehensive simulator-based instruction allows for realistic training without compromising worker, equipment, and environmental safety. It also better prepares operators and engineers to manage the plant closer to economic constraints while minimizing or avoiding the impact of any potentially harmful, wasteful, or inefficient events. The AVESTAR Center is also used to augment graduate and undergraduate engineering education in the areas of process simulation, dynamics, control, and safety. Students and researchers gain hands-on simulator-based training experience and learn how the commercial-scale power plants respond dynamically to changes in manipulated inputs, such as coal feed flow rate and power demand. Students also analyze how the regulatory control system impacts power plant performance and stability. In addition, students practice start-up, shutdown, and malfunction scenarios. The 3D virtual ITSs are used for plant familiarization, walk-through, equipment animations, and safety scenarios. To further leverage the AVESTAR facilities and simulators, NETL and its university partners are pursuing an innovative and collaborative R&D program. In the area of process control, AVESTAR researchers are developing enhanced strategies for regulatory control and coordinated plant-wide control, including gasifier and gas turbine lead, as well as advanced process control using model predictive control (MPC) techniques. Other AVESTAR R&D focus areas include high-fidelity equipment modeling using partial differential equations, dynamic reduced order modeling, optimal sensor placement, 3D virtual plant simulation, and modern grid. NETL and its partners plan to continue building the AVESTAR portfolio of dynamic simulators, immersive training systems, and advanced research capabilities to satisfy industry’s growing need for training and experience with the operation and control of clean energy plants. Future dynamic simulators under development include natural gas combined cycle (NGCC) and supercritical pulverized coal (SCPC) plants with post-combustion CO2 capture. These dynamic simulators are targeted for use in establishing a Virtual Carbon Capture Center (VCCC), similar in concept to the DOE’s National Carbon Capture Center for slipstream testing. The VCCC will enable developers of CO2 capture technologies to integrate, test, and optimize the operation of their dynamic capture models within the context of baseline power plant dynamic models. The objective is to provide hands-on, simulator-based “learn-by-operating” test platforms to accelerate the scale-up and deployment of CO2 capture technologies. Future AVESTAR plans also include pursuing R&D on the dynamics, operation, and control of integrated electricity generation and storage systems for the modern grid era. Special emphasis will be given to combining load-following energy plants with renewable and distributed generating supplies and fast-ramping energy storage systems to provide near constant baseload power.

97 MATHEMATICS AND COMPUTING↗

LEvEL: Low-Energy Neutrino Experiment at the LHC

We propose the operation of LEvEL, the Low-Energy Neutrino Experiment at the LHC, a neutrino detector near the Large Hadron Collider Beam Dump. Such a detector is capable of exploring an intense, low-energy neutrino flux and can measure neutrino cross sections that have previously never been observed. These cross sections can inform other future neutrino experiments, such as those aiming to observe neutrinos from supernovae, allowing such measurements to accomplish their fundamental physics goals. We perform detailed simulations to determine neutrino production at the LHC beam dump, as well as neutron and muon backgrounds. Measurements at a few to ten percent precision of neutrino-argon charged current and neutrino-nucleus coherent scattering cross sections are attainable with 100 ton-year and 1 ton-year exposures at LEvEL, respectively, concurrent with the operation of the High Luminosity LHC. We also estimate signal and backgrounds for an experiment exploiting the forward direction of the LHC beam dump, which could measure neutrinos above 100 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Contributed Review: Absolute spectral radiance calibration of fiber-optic shock-temperature pyrometers using a coiled-coil irradiance standard lamp

We describe an accurate and precise calibration procedure for multichannel optical pyrometers such as the 6-channel, 3-ns temporal resolution instrument used in the Caltech experimental geophysics laboratory. We begin with a review of calibration sources for shock temperatures in the 3000-30 000 K range. High-power, coiled tungsten halogen standards of spectral irradiance appear to be the only practical alternative to NIST-traceable tungsten ribbon lamps, which are no longer available with large enough calibrated area. However, non-uniform radiance complicates the use of such coiled lamps for reliable and reproducible calibration of pyrometers that employ imaging or relay optics. Careful analysis of documented methods of shock pyrometer calibration to coiled irradiance standard lamps shows that only one technique, not directly applicable in our case, is free of major radiometric errors. We provide a detailed description of the modified Caltech pyrometer instrument and a procedure for its absolute spectral radiance calibration, accurate to ±5%. We employ a designated central area of a 0.7× demagnified image of a coiled-coil tungsten halogen lamp filament, cross-calibrated against a NIST-traceable tungsten ribbon lamp. We give the results of the cross-calibration along with descriptions of the optical arrangement, data acquisition, and processing. We describe a procedure to characterize the difference between the static and dynamic response of amplified photodetectors, allowing time-dependent photodiode correction factors for spectral radiance histories from shock experiments. We validate correct operation of the modified Caltech pyrometer with actual shock temperature experiments on single-crystal NaCl and MgO and obtain very good agreement with the literature data for these substances. We conclude with a summary of the most essential requirements for error-free calibration of a fiber-optic shock-temperature pyrometer using a high-power coiled tungsten halogen irradiance standard lamp.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-Scale Multi-physics Methods Development for the Calculation of Hot-Spots in the NGNP

Radioactive gaseous fission products are released out of the fuel element at a significantly higher rate when the fuel temperature exceeds 1600°C in high-temperature gas-cooled reactors (HTGRs). Therefore, it is of paramount importance to accurately predict the peak fuel temperature during all operational and design-basis accident conditions. The current methods used to predict the peak fuel temperature in HTGRs, such as the Next-Generation Nuclear Plant (NGNP), estimate the average fuel temperature in a computational mesh modeling hundreds of fuel pebbles or a fuel assembly in a pebble-bed reactor (PBR) or prismatic block type reactor (PMR), respectively. Experiments conducted in operating HTGRs indicate considerable uncertainty in the current methods and correlations used to predict actual temperatures. The objective of this project is to improve the accuracy in the prediction of local "hot" spots by developing multi-scale, multi-physics methods and implementing them within the framework of established codes used for NGNP analysis.The multi-scale approach which this project will implement begins with defining suitable scales for a physical and mathematical model and then deriving and applying the appropriate boundary conditions between scales. The macro scale is the greatest length that describes the entire reactor, whereas the meso scale models only a fuel block in a prismatic reactor and ten to hundreds of pebbles in a pebble bed reactor. The smallest scale is the micro scale--the level of a fuel kernel of the pebble in a PBR and fuel compact in a PMR--which needs to be resolved in order to calculate the peak temperature in a fuel kernel.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Quantifying concentration distributions in redox flow batteries with neutron radiography

Abstract The continued advancement of electrochemical technologies requires an increasingly detailed understanding of the microscopic processes that control their performance, inspiring the development of new multi-modal diagnostic techniques. Here, we introduce a neutron imaging approach to enable the quantification of spatial and temporal variations in species concentrations within an operating redox flow cell. Specifically, we leverage the high attenuation of redox-active organic materials (high hydrogen content) and supporting electrolytes (boron-containing) in solution and perform subtractive neutron imaging of active species and supporting electrolyte. To resolve the concentration profiles across the electrodes, we employ an in-plane imaging configuration and correlate the concentration profiles to cell performance with polarization experiments under different operating conditions. Finally, we use time-of-flight neutron imaging to deconvolute concentrations of active species and supporting electrolyte during operation. Using this approach, we evaluate the influence of cell polarity, voltage bias and flow rate on the concentration distribution within the flow cell and correlate these with the macroscopic performance, thus obtaining an unprecedented level of insight into reactive mass transport. Ultimately, this diagnostic technique can be applied to a range of (electro)chemical technologies and may accelerate the development of new materials and reactor designs.

Science & Technology - Other Topics↗

Development and validation of a radial inflow turbine model for simulation of the SNL S-CO 2 split-flow loop

A one-dimensional model for a radial inflow turbine has been developed for super-critical carbon dioxide (S-CO 2 ) Brayton cycle applications. The model accounts for the main phenomena present in the volute, nozzle, and impeller of a single-stage turbine. These phenomena include internal losses due to friction, blade loading, and angle of incidence and parasitic losses due to windage and blade-housing leakage. The model has been added as a component to the G-PASS plant systems code. The model was developed to support the analysis of S-CO 2 cycles in conjunction with small-scale loop experiments. Such loops operate at less than a MWt thermal input. Their size permits components to be reconfigured in new arrangements relatively easily and economically. However, the small thermal input combined with the properties of carbon dioxide lead to turbomachines with impeller diameters of only one to two inches. At these sizes the dominant phenomena differ from those in larger more typical machines. There is almost no treatment in the literature of turbomachines at these sizes. The present work therefore is aimed at developing turbomachine models that support the task of S-CO 2 cycle analysis using small-scale tests. Model predictions were compared against data from an experiment performed for Sandia National Laboratories in the split-flow Brayton cycle loop currently located at Barber-Nichols Inc. The split-flow loop incorporates two turbo-alternator-compressor (TAC) units each incorporating a radial inflow turbine and a radial flow compressor on a common shaft. The predicted thermodynamic conditions at the outlet of the turbine on the main compressor shaft were compared with measured values at different shaft speeds. Two modifications to the original model were needed to better match the experiment data. First, a representation of the heat loss from the volute downstream of the sensed inlet temperature was added. Second, an empirical multiplicative factor was applied to the Euler head and another to the head loss to bring the predicted outlet pressure into better agreement with the experiment. These changes also brought the overall efficiency of the turbine into agreement with values cited by Barber Nichols for small turbines. More generally, the quality of measurement set data can in the future be improved by additional steps taken in the design and operation of the experimental apparatus. First, a thermocouple mounted at the nozzle inlet would provide a better indication of temperature at this key point. Second, heat losses from the turbine should be measured directly. Allowing the impeller to free wheel at inlet conditions and measuring the temperature drop between inlet and outlet would provide a more accurate measure of heat loss. Finally, the enthalpy change during operation is more accurately obtained by measuring the torque on the stator using strain gauges rather than by measuring pressure and temperature at inlet and outlet to infer thermodynamic states.

42 ENGINEERING↗

ChargeX OCPI Recommendations

The Open Charge Point Interface (OCPI) is an open protocol that enables electric vehicle (EV) charging systems to work together across networks. It supports communication and data sharing between Charge Point Operators (CPOs), who manage charging stations, and e-Mobility Service Providers (eMSPs), who provide charging services to EV drivers. OCPI facilitates functions like user authorization, remote charge point control, charging session data exchange, and billing through Charge Detail Records (CDRs). This allows EV roaming, so drivers can charge at different networks without multiple accounts. As the EV market grows due to increased adoption and technological advancements, OCPI faces higher demands. This has revealed issues with CDR format consistency, timestamp standardization across regions, transmission of EV-side error codes for troubleshooting, and support for new use cases. These challenges can affect operations and user experience, particularly as the industry starts considering Vehicle-to-Grid (V2G) systems, where EVs supply energy to the grid, and Vehicle-to-Everything (V2X) technologies for broader energy interactions. Using feedback from the ChargeX Diagnostics taskforce discussions, industry 1-on-1 meetings, technical standards, and OCPI’s evolution through versions (e.g., OCPI 2.1.1, 2.2, and 2.2.1), this report identifies these issues and suggests practical recommendations. These aim to improve interoperability, streamline operations, and prepare OCPI for future trends in the EV charging ecosystem.

32 - ENERGY CONSERVATION, CONSUMPTION, AND UTILIZA↗

Deployment of magnetometers to monitor stray magnetic fields near the PROSPECT detector

PROSPECT is a reactor antineutrino experiment located in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory. PROSPECT’s primary goals are to probe short-baseline oscillations and perform a precise measurement of the U-235 reactor antineutrino spectrum. The detector consists of 154 segmented cells filled with 6Li-doped liquid scintillator. Each segment holds two PMTs, one on each end of the cell. The PMTs can be exposed to stray magnetic fields from superconducting magnets operating on the experiment hall one floor below the detector. The monitoring of the magnetic fields is an important part of our background characterization as the magnetic fields can directly influence the energy measurement. This study presents the characterization and monitoring of stray magnetic fields using triple axis magnetometers near the detector.

Gilbert, Corey E.↗

HIGH FUSION PERFORMANCE IN SUPER H-MODE EXPERIMENTS ON ALCATOR C-MOD AND DIII-D

We report that the “Super H-Mode” regime is predicted to enable pedestal height and fusion performance substantially higher than standard H-Mode operation. This regime exists due to a bifurcation of the pedestal pressure, as a function of density, that is predicted by the EPED model to occur in strongly shaped plasmas above a critical pedestal density. Experiments on Alcator C-Mod and DIII-D have achieved access to the Super H-Mode (and Near Super H) regime, and obtained very high pedestal pressure, including the highest pedestal pressure ever achieved on a tokamak (p ped ~80kPa) in C-Mod experiments operating near the ITER magnetic field. DIII-D Super H experiments have demonstrated high performance, including the highest stored energy in the present configuration of DIII-D (W~2.2-3.2MJ), while utilizing only about half of the available heating power (P heat ~7-12 MW). These DIII-D experiments have obtained the highest value of peak fusion gain, Q DT,equiv ~0.5, ever achieved on a medium scale (R<2m) tokamak. Sustained high performance operation (β N ~2.9, H 98 ~1.6) has been achieved utilizing n=3 magnetic perturbations for density and impurity control. High pedestal and global performance has been maintained in the presence of deuterium and nitrogen gas puffing, which enables a more radiative divertor condition. Lastly, Super H-Mode access is predicted for ITER and expected, based on both theoretical prediction and observed normalized performance, to allow ITER to achieve its performance goals (Q=10) at I p < 15MA, and to enable more compact, cost effective pilot plant and reactor designs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗