Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical signal processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Fiber optic sensors with internal referencing

The main problem with amplitude modulating type sensors is that any variation in the intensity of the optical signal which occurs throughout the sensing system is interpreted by the photodetector as resulting from the sensor itself and is reflected as an error in the sensed parameter. To account for these errors, a referencing technique with the signal and reference channels separated in the time domain over the same fiber link can be used. Selected sensing and signal processing techniques involving temporally separated signal and referencing channels are described. A transition from the time into the frequency domain is also discussed. Experimental data are presented.

Adamovsky, Grigory↗

What Initiates Lightning?

Lightning is an energetic electric discharge, creating a current that flows briefly within a cloud--or between a cloud and the ground--and heating the air to temperatures about five times hotter than the sun’s surface. But there’s a lot about lightning that’s still a mystery. Los Alamos National Laboratory is working to change that. Because lightning produces optical and radio frequency signals similar to those from a nuclear explosion, it’s important to be able to distinguish whether such signals are caused by lightning or a nuclear event. As part of the global security mission at Los Alamos, scientists use lightning to help develop better instruments for nuclear test-ban treaty monitoring and, in the process, have learned a lot about lightning itself.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrafast spin-state photoswitching in a crystal and slower consecutive processes investigated by femtosecond optical spectroscopy and picosecond X-ray diffraction

We report the spin state photo-switching dynamics in two polymorphs of a spin-crossover molecular complex triggered by a femtosecond laser flash, as determined by combining femtosecond optical pump-probe spectroscopy and picosecond X-ray diffraction techniques. The light-driven transformations in the two polymorphs are compared. Combining both techniques and tracking how the X-ray data correlate with optical signals allow understanding of how electronic and structural degrees of freedom couple and play their role when the switchable molecules interact in the active crystalline medium. The study sheds light on crossing the border between femtochemistry at the molecular scale and femtoswitching at the material scale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantum process tomography by 2D fluorescence spectroscopy

Reconstruction of the dynamics (quantum process tomography) of the single-exciton manifold in energy transfer systems is proposed here on the basis of two-dimensional fluorescence spectroscopy (2D-FS) with phase-modulation. The quantum-process-tomography protocol introduced here benefits from, e.g., the sensitivity enhancement ascribed to 2D-FS. Although the isotropically averaged spectroscopic signals depend on the quantum yield parameter Γ of the doubly excited-exciton manifold, it is shown that the reconstruction of the dynamics is insensitive to this parameter. Applications to foundational and applied problems, as well as further extensions, are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Environmentally Adaptive, Multiband Software-Defined-Radar for Monitoring of Item of Interest in a Dynamically Cluttered Room

High-resolution multi-frequency radars when networked together, form a robust and seamless monitoring system for high-valued items. The multi-look-direction radar network investigated by LLNL and DSI, operates at 77 GHz and 5.8GHz, and is capable of detection at centimeter resolution movement of objects of interest. This dual frequency radar (unlike optical methods) can operate under various environments with conditions such a smoke, dust, and other natural or manmade obscurations. In addition, the multiband network radar is based on low-cost FCC approved EM specifications and can be scaled with the dimensions of the room and objects under consideration by user-defined inputs. Furthermore, the underlying radar signal processing based on software-defined radar engine is adaptive to its operational environment, where operators can input the size of the facility and object of interest and the distance between the object and radar. Finally, this multi-frequency radar employs a host of change detection and machine learning algorithms to reach performance levels in terms of high probability of detection and low false alarm rates while the monitoring state of the object can be reported remotely.

42 ENGINEERING↗

Enhancements to Lab-on-a-Fish Technology: Final Report for I3T Project 81245

PNNL has engaged in discussions with several organizations regarding potential future collaborations. PNNL has developed the Lab-on-a-Fish prototypes and produced video instructions for an organization conducting research on shark eggs. Several organizations have expressed interest in using the Lab-on-a-Fish for their studies. We’ve also updated two versions of the Lab-on-a-Fish to expand its applications to a wider range of animal studies and accelerate its commercialization. The new design of the Lab-on-a-Fish, which incorporates PCB-based electrodes, has demonstrated the ability to capture clear ECG signals without the need for additional needle-shaped electrodes. This innovation eliminates the need for implanting electrodes beneath the fish's skin at specific locations, which is required with the current version of Lab-on-a-Fish. This change significantly simplifies the manufacturing and implantation process. For the Lab-on-a-Fish design that uses an optical pulse oximeter, the measurement results were primarily influenced by respiratory activity rather than heart rate. This occurred because the oximeter was placed beneath the operculum. Further research and development are needed to explore more suitable locations and methods for accurate pulse oximeter measurements.

59 BASIC BIOLOGICAL SCIENCES↗

A long-range laser velocimeter for the National Full-Scale Aerodynamics Complex: New developments and experimental application

A long-range laser velocimeter (LV) developed for remote operation from within the flow fields of the large wind tunnels of the National Full-Scale Aerodynamics Complex is described. Emphasis is placed on recent improvements in optical hardware as well as recent additions to data acquisition and processing techniques. The system has been upgraded from a dual-beam, single-color LV with focal range to 10 m, to a dual-beam, two-color LV with focal range to 20 m. At the new extended measurement range (between 10 and 20 m), signals are photon-resolved, and a photon correlation technique is applied to acquire and process the LV signals. This technique permits recovery of the velocity probability distributions at a particular measurement location from which the mean components of velocity and the corresponding normal stress components of turbulence are obtained. The method used for data reduction is outlined in detail, and a discussion of measurement accuracy is made. To study the performance of the LV and verify the measurement accuracy, laboratory measurements were made in the flow field of a 10 cm-diameter, 30-m/sec axisymmetric jet. A discussion of the requirements and techniques used to seed the flow is made, and boundary-layer surveys of mean velocity and turbulence intensity of the streamwise component and the component normal to the surface are presented.

Reinath, Michael S.↗

A compact high repetition rate CO2 coherent Doppler lidar

As part of its program to develop coherent heterodyne detection lidar technology for space, airborne, and ground based applications, the Optical Environment Division of the USAF's Phillips Laboratory developed a compact coherent CO2 TEA lidar system. Although originally conceived as a high altitude balloon borne system, the lidar is presently integrated into a trailer for ground based field measurements of aerosols and wind fields. In this role, it will also serve as a testbed for signal acquisition and processing development for planned future airborne and space based solid state lidar systems. The system has also found significance in new areas of interest to the Air Force such as cloud studies and coherent Differential Absorption Lidar (DIAL) systems.

Alejandro, S.↗

Acoustical sensing of cardiomyocyte cluster beating

Highlights: •An example of the application of QCM-D to live cell studies. •Detection of human pluripotent stem cell-derived cardiomyocyte cluster beating. •Clusters were studied in a thin liquid film and in a large liquid volume. •The QCM-D beating profile provides an individual fingerprint of the hPS-CMCs. -- Abstract: Spontaneously beating human pluripotent stem cell-derived cardiomyocytes clusters (CMCs) represent an excellent in vitro tool for studies of human cardiomyocyte function and for pharmacological cardiac safety assessment. Such testing typically requires highly trained operators, precision plating, or large cell quantities, and there is a demand for real-time, label-free monitoring of small cell quantities, especially rare cells and tissue-like structures. Array formats based on sensing of electrical or optical properties of cells are being developed and in use by the pharmaceutical industry. A potential alternative to these techniques is represented by the quartz crystal microbalance with dissipation monitoring (QCM-D) technique, which is an acoustic surface sensitive technique that measures changes in mass and viscoelastic properties close to the sensor surface (from nm to μm). There is an increasing number of studies where QCM-D has successfully been applied to monitor properties of cells and cellular processes. In the present study, we show that spontaneous beating of CMCs on QCM-D sensors can be clearly detected, both in the frequency and the dissipation signals. Beating rates in the range of 66–168 bpm for CMCs were detected and confirmed by simultaneous light microscopy. The QCM-D beating profile was found to provide individual fingerprints of the hPS-CMCs. The presented results point towards acoustical assays for evaluation cardiotoxicity.

60 APPLIED LIFE SCIENCES↗

A synthetic aperture processor using CCD signal processing techniques

Synthetic aperture radar (SAR) imaging was the most suitable technique for achieving high resolution imagery through atmospheric cloud cover. This feature was important for planetary as well as earth orbiting satellite systems, and for military aircraft applications. Such applications require onboard data processing or wide-band data transmission systems in order to handle the large amounts of raw data produced by such systems. A number of techniques were utilized in implementing SAR processors. Frequency filtering and Fourier transform operations using both optical and digital techniques were utilized in SAR processing.

Bailey, W. H.↗

Experimental observation of stochastic resonance in a solid-state ring laser in the absence of bistability

The appearance of a stochastic resonance is found in a solid-state ring laser in the absence of bistability in it. It is shown that in this laser operating in the self-modulation regime of the first kind, the noise modulation of the pump can cause a significant increase in the laser response to the periodic modulating signal. These effects observed are explained qualitatively. (nonlinear optical phenomena)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nonlinear optical processes for the mid-IR region

The 2 - 5 micron (mid-IR) region is of interest for a number of applications. Efficient up-conversion and down-conversion techniques are being developed to obtain optical sources at mid-IR wavelengths. These techniques are reviewed and recent results using AgGaSe2 are reported. Gain in AgGaSe2 as high as 13 has been observed with a pump wavelength of 1.73 microns and a signal wavelength of 3.39 microns. Optical parametric oscillation in the 2.9 - 6.8 micron region has also been demonstrated.

Schepler, K. L.↗

Contribution of Phycoerythrin-Containing Phytoplankton to Remotely Sensed Signals in the Ocean

The purpose of this project was to evaluate the importance of phycoerythrin-containing phytoplankton, in particular coccoid cyanobacteria, to remote sensing. We proposed to estimate cyanobacteria abundance and pigmentation and their relationship to water-column optics. We have estimated the contribution of cyanobacteria to scattering and backscattering in both open ocean (Sargasso Sea) and coastal waters (western coast of North Atlantic and the California Current). Sampling and data processing is performed. Relationship between water column optics and phycoerythrin concentration and algorithms development are being carried out.

Vernet, Maria↗

Monitoring Ultrafast Spin Crossover Intermediates in an Iron(II) Complex by Broad Band Stimulated X-ray Raman Spectroscopy

Here, the photoinduced spin crossover dynamics of transition metal complexes is of fundamental scientific importance and is used for sensor device applications and solar energy harvesting. Current X-ray and optical spectroscopy experiments for [Fe II (bpy) 3 ], an archetypal earth-abundant metal complex, show conflicting spin dynamics. We have simulated the broad band transient X-ray absorption and hybrid (broad + narrow band) X-ray stimulated Raman signals at the N and Fe K-edges of the key excited state intermediates involved in the spin crossover process of this complex. We find that these signals are much more sensitive to electron and spin populations than transition absorption and may be useful in the design of photovoltaic and artificial photosynthetic systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Noncollinear, inelastic four-wave mixing in the extreme ultraviolet

Driving four-wave mixing (FWM) processes with extreme ultraviolet (EUV) pulses could enable experimental approaches that have the potential to provide unique information on dynamics and correlations. In this work, we demonstrate inelastic FWM obtained by noncollinear mixing of two EUV pulses with different photon energies and an optical pulse in a diamond sample. This three-pulse interaction leads to the emission of an optical signal, propagating in the phase-matching direction and blue shifted by the photon energy difference of the two EUV pulses. The presented results demonstrate the feasibility of experiments such as the soft X-ray analogue of coherent anti-Stokes Raman scattering, so far only theoretically conceived [ Phys. Rev. Lett. 89 , 043001 ( 2002 ) PRLTAO 0031-9007 10.1103/PhysRevLett.89.043001 ], which can be further extended for studying vibrational and electronics dephasing in solid, liquid, or gaseous samples.

Mincigrucci, R. (ORCID:0000000163436256)↗

Slot clock recovery in optical PPM communication systems with avalanche photodiode photodetectors

Slot timing recovery in a direct-detection optical PPM communication system can be achieved by processing the photodetector output waveform with a nonlinear device whose output forms the input to a phase-locked loop. The choice of a simple transition detector as the nonlinearity is shown to give satisfactory synchronization performance. The rms phase error of the recovered slot clock and the effect of slot timing jitter on the bit error probability were directly measured. The experimental system consisted of an AlGaAs laser diode (wavelength = 834 nm) and a silicon avalanche photodiode photodetector. The system used Q = 4 PPM signaling and operated at a source data rate of 25 Mbits/s. The mathematical model developed to compute the rms phase error of the recovered clock is shown to be in good agreement with results of actual measurements of phase errors. The use of the recovered slot clock in the receiver resulted in no significant degradation in receiver sensitivity compared to a system with perfect slot timing. The system achieved a bit error probability of 10 to the -6th at a received optical signal energy of 55 detected photons per information bit.

Davidson, Frederic M.↗

The persistence of memory in ionic conduction probed by nonlinear optics

Predicting practical rates of transport in condensed phases enables the rational design of materials, devices and processes. This is especially critical to developing low-carbon energy technologies such as rechargeable batteries. For ionic conduction, the collective mechanisms, variation of conductivity with timescales and confinement, and ambiguity in the phononic origin of translation, call for a direct probe of the fundamental steps of ionic diffusion: ion hops. However, such hops are rare-event large-amplitude translations, and are challenging to excite and detect. Here we use single-cycle terahertz pumps to impulsively trigger ionic hopping in battery solid electrolytes. This is visualized by an induced transient birefringence, enabling direct probing of anisotropy in ionic hopping on the picosecond timescale. The relaxation of the transient signal measures the decay of orientational memory, and the production of entropy in diffusion. We extend experimental results using in silico transient birefringence to identify vibrational attempt frequencies for ion hopping. Using nonlinear optical methods, we probe ion transport at its fastest limit, distinguish correlated conduction mechanisms from a true random walk at the atomic scale, and demonstrate the connection between activated transport and the thermodynamics of information.

25 ENERGY STORAGE↗

High-sensitive scanning laser magneto-optical imaging system

A high-sensitive scanning laser magneto-optical (MO) imaging system has been developed. The system is mainly composed of a laser source, galvano meters, and a high-sensitive differential optical-detector. Preliminary evaluation of system performance by using a Faraday indicator with a Faraday rotation coefficient of 3.47x10{sup -5} rad/{mu}m Oe shows a magnetic sensitivity of about 5 {mu}T, without any need for accumulation or averaging processing. Using the developed MO system we have succeeded in the fast and quantitative imaging of a rotationally symmetric magnetic field distribution around an YBa{sub 2}Cu{sub 3}O{sub 7-{delta}} (YBCO) strip line applied with dc-biased current, and also succeeded in the detection of quantized fine signals corresponding to magnetic flux quantum generation in a superconducting loop of an YBCO Josephson vortex flow transistor. Thus, the developed system enables us not only to do fast imaging and local signal detection but also to directly evaluate both the strength and direction of a magnetic signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗