Search NASA⌕ Search

SEARCH · Search NASA

Results for “PUMPS - SCAVENGING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Compressor Selection and Equipment Sizing for Cold Climate Heat Pumps

In order to limit heating capacity degradation at -25 C (-13 F) ambient to 25%, compared to the nominal rating point capacity at 8.3 C (47 F), an extensive array of design and sizing options were investigated, based on fundamental equipment system modeling and building energy simulation. Sixteen equipment design options were evaluated in one commercial building and one residential building, respectively in seven cities. The energy simulation results were compared to three baseline cases: 100% electric resistance heating, a 9.6 HSPF single-speed heat pump unit, and 90% AFUE gas heating system. The general recommendation is that variable-speed compressors and tandem compressors, sized such that their rated heating capacity at a low speed matching the building design cooling load, are able to achieve the capacity goal at low ambient temperatures by over-speeding, for example, a home with a 3.0 ton design cooling load, a tandem heat pump could meet this cooling load running a single compressor, while running both compressors to meet heating load at low ambient temperatures in a cold climate. Energy savings and electric resistance heat reductions vary with building types, energy codes and climate zones. Oversizing a heat pump can result in larger energy saving in a less energy efficient building and colder regions due to reducing electric resistance heating. However, in a more energy-efficient building or for buildings in warmer climates, one has to consider balance between reduction of resistance heat and addition of cyclic loss.

Building Energy Simulation↗

Multiphysics analysis of liquid metal annular linear induction pumps: A project overview

Liquid metal-cooled fission reactors are both moderated and cooled by a liquid metal solution. These reactors are typically very compact and they can be used in regular electric power production, for naval and space propulsion systems or in fission surface power systems for planetary exploration. The coupling between the electromagnetics and thermo-fluid mechanical phenomena observed in liquid metal thermo-magnetic systems for nuclear and space applications gives rise to complex engineering magnetohydrodynamics and numerical problems. It is known that electromagnetic pumps have a number of advantages over rotating mechanisms: absence of moving parts, low noise and vibration level, simplicity of flow rate regulation, easy maintenance and so on. However, while developing annular linear induction pumps, we are faced with a significant problem of magnetohydrodynamic instability arising in the device. The complex flow behavior in this type of devices includes a time-varying Lorentz force and pressure pulsation due to the time-varying electromagnetic fields and the induced convective currents that originates from the liquid metal flow, leading to instability problems along the device geometry. The determinations of the geometry and electrical configuration of liquid metal thermo-magnetic devices give rise to a complex inverse magnetohydrodynamic field problem were techniques for global optimization should be used, magnetohydrodynamics instabilities understood –or quantified- and multiphysics models developed and analyzed. Lastly, we present a project overview as well as a few computational models developed to study liquid metal annular linear induction pumps using first principles and the a few results of our multi-physics analysis.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quantifying Systemic Efficiency using Exergy and Energy Analysis for Ground Source Heat Pumps: Domestic Space Conditioning and Water Heating Applications.

Although air temperatures over land surfaces show wide seasonal and daily variations, the ground, approximately 10 meters below the earth s surface, remains relatively stable in temperature thereby serving as an energy source or sink. Ground source heat pumps can heat, cool, and supply homes with hot water efficiently by utilizing the earth s renewable and essentially inexhaustible energy resources, saving fossil fuels, reducing greenhouse gas emissions, and lowering the environmental footprint. In this paper, evidence is shown that ground source heat pumps can provide up to 79%-87% of domestic hot water energy needs, and up to 77% of space heating needs with the ground s thermal energy resources. The case refers to a 12-month study conducted at a 253 m2 research house located in Oak Ridge, Tennessee, 36.01 N 84.26 W in a mixed-humid climate with HDD of 2218 C-days and CDD of 723 C-days under simulated occupancy conditions. A single 94.5m vertical bore interfaced the heat pump with the ground. The research shows that this technology is capable of achieving US DOE targets of 25 % and 35% energy savings in HVAC, and in water heating, respectively by 2030. It is also a viable technology to meet greenhouse gas target emissions under the IECC 2012 Standard, as well as the European Union (EU) 2020 targets of using renewable energy resources. The paper quantifies systemic efficiencies using Exergy analysis of the major components, clearly pointing areas for further improvement.

exergy↗

Transforming the U.S. Market with a New Application of Ternary-Type Pumped-Storage Hydropower Technology: Preprint

As the deployment of wind and solar technologies increases at an unprecedented rate across the United States and in many world markets, the variability of power output from these technologies expands the need for increased power system flexibility. Energy storage can play an important role in the transition to a more flexible power system that can accommodate high penetrations of variable renewable technologies. This project focuses on how ternary pumped storage hydropower (T-PSH) coupled with dynamic transmission can help this transition by defining the system-wide benefits of deploying this technology in specific U.S. markets. T-PSH technology is the fastest responding pumped hydro technology equipment available today for grid services. T-PSH efficiencies are competitive with lithium-ion (Li-ion) batteries, and T-PSH can provide increased storage capacity with minimal degradation during a 50-year lifetime. This project evaluates T-PSH for grid services ranging from fast frequency response (FFR) for power system contingency events and enhanced power system stability to longer time periods for power system flexibility to accommodate ramping from wind and solar variability and energy arbitrage. In summary, this project: Compares power grid services and costs, including ancillary services and essential reliability services, for T-PSH and conventional pumped storage hydropower (PSH) - Evaluates the dynamic response of T-PSH and PSH technologies and their contribution to essential reliability services for grid stability by developing new power system model representations for T-PSH and performing simulations in the Western Interconnection - Evaluates production costs, operational impacts, and energy storage revenue streams for future power system scenarios with T-PSH focusing on time frames of 5 minutes and more - Assesses the electricity market-transforming capabilities of T-PSH technology coupled with transmission monitoring and dynamic control. This paper presents an overview of the methodology and initial, first-year preliminary findings of a 2-year in-depth study into how advanced PSH and dynamic transmission contribute to the transformation and modernization of the U.S. electric grid. This project is part of the HydroNEXT Initiative funded by the U.S. Department of Energy (DOE) that is focused on the development of innovative technologies to advance nonpowered dams and PSH. The project team consists of the National Renewable Energy Laboratory (project lead), Absaroka Energy, LLC (Montana-based PSH project developer), GE Renewable Energy (PSH pump/turbine equipment supplier), Grid Dynamics, and Auburn University (lead for NREL/Auburn dynamic modeling team).

13 HYDRO ENERGY↗

Performance Considerations for Ground Source Heat Pumps in Cold Climates: Preprint

Remote, cold climates present challenges to finding safe and affordable options to heat homes. In Alaska, residential ground source heat pumps (GSHPs) have been gaining in popularity to fill this gap. However, there is little research on their long-term performance or effect on soil temperatures. The extended heating season and cold soils of Alaska provide a harsh testing ground for GSHPs, even those designed and marketed for colder climates. The large and unbalanced heating load of cold climates creates a challenging environment for GSHPs. In 2013 the Cold Climate Housing Research Center (CCHRC) installed a GSHP at its Research and Testing Facility (RTF) in Fairbanks, Alaska. The heat pump replaced an oil-fired condensing boiler heating a 464 m2 office space via an in-floor hydronic radiant heating system. The ground heat exchanger (GHE) was installed in moisture-rich silty soils underlain with permafrost near 0°C. The intent of the installation was to observe and monitor the system over a 10-year period in order to develop a better understanding of the performance of GSHPs in sites with permafrost and to help inform future design. As of this writing, the heat pump system has been running for seven heating seasons. The efficiency in those seven heating seasons has been variable with ups and downs that have been difficult to explain. This paper seeks to understand the variability in performance as well as make recommendations for GSHP use in other cold climates.

cold climate↗

Lessons Learned from the 200 West Pump and Treatment Facility Construction Project at the US DOE Hanford Site - A Leadership for Energy and Environmental Design (LEED) Gold-Certified Facility - 13113

CH2M Hill Plateau Remediation Company (CHPRC) designed, constructed, commissioned, and began operation of the largest groundwater pump and treatment facility in the U.S. Department of Energy's (DOE) nationwide complex. This one-of-a-kind groundwater pump and treatment facility, located at the Hanford Nuclear Reservation Site (Hanford Site) in Washington State, was built to an accelerated schedule with American Recovery and Reinvestment Act (ARRA) funds. There were many contractual, technical, configuration management, quality, safety, and Leadership in Energy and Environmental Design (LEED) challenges associated with the design, procurement, construction, and commissioning of this $95 million, 52,000 ft groundwater pump and treatment facility to meet DOE's mission objective of treating contaminated groundwater at the Hanford Site with a new facility by June 28, 2012. The project team's successful integration of the project's core values and green energy technology throughout design, procurement, construction, and start-up of this complex, first-of-its-kind Bio Process facility resulted in successful achievement of DOE's mission objective, as well as attainment of LEED GOLD certification (Figure 1), which makes this Bio Process facility the first non-administrative building in the DOE Office of Environmental Management complex to earn such an award. (authors)

54 ENVIRONMENTAL SCIENCES↗

Modeling and Validation of a Residential Multi-Functional Variable Refrigerant Flow Heat Pump System with Heat Recovery

To bridge the existing gap in modeling the variable refrigerant flow heat pump systems with heat recovery (VRFHR), we developed a suite of dynamic VRFHR system models in Modelica. These models are specifically tailored for residential multi-functional VRFHR (MF-VRFHR) applications, including space conditioning and domestic hot water (DHW) heating, utilizing both the TIL library for HVAC equipment and the Buildings library for thermal load calculations. The development comprises essential component models, including the newly developed heat recovery unit (HRU), along with system models that integrate the heat pump system and building envelope. These system models accommodate various operational modes such as heating-only, cooling-only, and heating-recovery (including heating-dominant and cooling-dominant) modes. Furthermore, we propose an efficient optimization-based model calibration method that identifies critical model parameters while utilizing a small amount of data obtained from either real systems or manufacturer's specifications. We demonstrate the effectiveness of these models and the proposed calibration method for a MF-VRFHR system installed in Richland, WA. The developed models are calibrated and validated using data collected under different operational modes during both heating and cooling seasons. The results show that the models capture the system dynamics and achieve high accuracy, with the coefficient of the variation of the root-mean-square-error less than 15% for variables such as outdoor unit power consumption, compressor speed, space temperature and DHW temperature. The validated models serve as a reliable representation of the MF-VRFHR system, facilitating the development and validation of optimized controls needed to realize the full benefits of integrated heat pump systems. Future research will utilize these models to develop advanced controls and optimize system performance for improved energy efficiency and demand flexibility.

Modeling, Variable refrigerant flow (VRF) systems,↗

Geothermal Heat Pump System Showcase: Short-Term Validation of Borehole Heat Exchanger Performance from Field Data to Numerical Modeling: Preprint

Since 2011, a geothermal heat pump (GHP) system has been operating to provide space heating and cooling for the Solar Radiation and Research Laboratory building at the National Laboratory of the Rockies (NLR) in Golden, Colorado. The system consists of 23 vertical boreholes, each extending to a depth of 300 ft (91 m), connected to 11 water-to-air heat pump units and four circulation pumps. Between fiscal years 2023 and 2025, additional power meters and temperature sensors were retrofitted to support detailed system performance assessment and model development. This study presents preliminary monitoring results and the development of an initial numerical model of the borehole heat exchanger field. The model incorporated site-specific geometry, ground thermal properties derived from thermal response tests, and ambient temperatures, and simulated system behavior over a representative operating day in September. Model predictions of outlet temperatures were compared against corresponding field measurements. Results showed that modeling initialized with a simplified linear subsurface temperature gradient presents systematic discrepancies in outlet temperature, whereas incorporating depth-resolved borehole temperature measurements for initialization yields substantially improved agreement with observations. The findings highlight the sensitivity of short-term predictive modeling to the representation of initial subsurface thermal conditions and underscore the value of high-resolution field measurements for model calibration and validation. These preliminary results inform ongoing efforts to extend the modeling framework to longer time horizons and to refine monitoring and modeling strategies that support the design guidance and operational optimization of GHP systems in research and commercial buildings.

15 GEOTHERMAL ENERGY↗

GEO3D - Three-Dimensional Computer Model of a Ground Source Heat Pump System

This file is the setup file for GEO3D, a computer program written by Jim Menart to simulate vertical wells in conjunction with a heat pump for ground source heat pump (GSHP) systems. This is a very detailed three-dimensional computer model. This program produces detailed heat transfer and temperature field information for a vertical GSHP system.

15 GEOTHERMAL ENERGY↗

Investigation of Heat Pump Technologies with Potential for Ultra-High Temperature Applications

This report provides a comprehensive investigation into heat pump (HP) technologies to achieve heat supply temperatures above 250°C, referred to as ultra-high-temperature heat pump (UHTHP). UHTHP, a low-carbon heat delivery and augmentation technology, offers an alternative to traditional combustion heating for decarbonizing high-temperature industrial processes. The scope of this review covers both mechanical and chemical HP technologies. The heat supply temperature of over 250°C pursued by UHTHP surpasses the temperature range typically covered in the high-temperature HP literature and existing capabilities of commercial HP systems. This report seeks to pinpoint technical gaps and challenges that have hindered widespread adoption of UHTHP in industry, explore potential improvements and solutions to address the challenges, and discuss its technical feasibility for practical contribution to industrial decarbonization. Current efforts are intended to lay the ground for future research and commercial deployment endeavors for UHTHP.

25 ENERGY STORAGE↗

Minimizing Auxiliary Heat Use for Cold Climate Operation of Air-Source Heat Pumps

This paper investigates the auxiliary heat use for air-source heat pumps (ASHPs) operating in cold climate conditions. Twelve variable-capacity, central ducted ASHPs installed in single-family homes in cold climate regions (eleven in northwest United States and one in Denver suburb) were monitored for an entire winter season to collect data at cold temperatures. The methodology employed airside and power measurements that were taken every five-seconds, to calculate heat pump's capacity, coefficient of performance (COP), and auxiliary heat energy consumption. This paper provides valuable insights into the practical implications of auxiliary heat utilization in centrally ducted ASHPs and suggests opportunities to mitigate the usage of auxiliary heat, improving the overall system efficiency during cold climate operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Minimizing Auxiliary Heat Use for Cold Climate Operation of Air Source Heat Pumps: Preprint

This paper investigates the auxiliary heat use for air-source heat pumps (ASHPs) operating in cold climates. Twelve variable-capacity, central ducted ASHPs installed in single-family homes in cold climate regions (eleven in the northwest United States and one in a Denver suburb) were monitored for an entire winter season to collect data at cold temperatures. The methodology employed airside and power measurements that were taken every five seconds, to calculate the heat pump’s capacity, coefficient of performance (COP), and auxiliary heat energy consumption. This paper provides insights into the practical implications of auxiliary heat utilization in centrally ducted ASHPs and suggests opportunities to mitigate the usage of auxiliary heat, improving overall system efficiency during cold climate operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bacterial Efflux Pumps and Their Inhibitors

Bacterial multidrug efflux transporters have distinct molecular features and mechanisms that enable their impressive substrate polyspecificity. These transporters are involved in all physiological processes where nonspecific but active transport across membranes is critical for survival and proliferation. Importantly, efflux pumps contribute to bacterial virulence and pathogenesis, as well as the spread of antibiotic resistance in clinics. Transporters belonging to several protein superfamilies have been selected for polyspecificity by evolution and augmented with accessory proteins that extend and couple transport reactions across the inner and outer membranes of the bacterium. As a result, bacteria are equipped with diverse efflux machines that protect cells from a broad variety of toxic compounds including antibiotics and other small molecule therapeutics. The inhibition of such polyspecific biomolecular machines is a challenging task, which still awaits an efficient solution. Here, we review the molecular mechanisms of efflux pumps from Gram-negative bacteria and recent advances and challenges associated with the discovery of effective inhibitors of these pumps.

Zgurskaya, Helen↗

Eye-Safe KGd(WO{sub 4}){sub 2} Raman Lasers: Comparative Study of Pumping of Nd:KGd(WO{sub 4}){sub 2} Lasers With {sup 4}F{sub 3/2} → {sup 4}I{sub 11/2} and {sup 4}F{sub 3/2} → {sup 4}I{sub 13/2} Working Transitions{sup **}

This is a comparative study of eye-safe extracavity KGd(WO{sub 4}){sub 2} (KGW) Raman lasers that convert multimode emission from pulsed Nd:KGW lasers operating on the {sup 4}F{sub 3/2} → {sup 4}I{sub 11/2} and {sup 4}F{sub 3/2} → {sup 4}I{sub 13/2} transitions into the third Stokes component at λ = 1500 nm and the first Stokes component at λ = 1507 or 1538 nm. For equal sizes of the Raman and laser sections of a Raman laser emitting the third Stokes component, the pulse energy is higher (~14.2 mJ) and the divergence of the Stokes beam is lower (~9.4 mrad) for a lower energy of the Nd:KGW laser (~6.7 J). For pump pulse energies of 29–34 mJ, all the Raman lasers have essentially the same optical lasing efficiency of up to 36%. In terms of the electrical energy delivered to the flashlamp, however, the overall efficiency of the Raman laser for the third Stokes component is a factor of ~1.7 higher. The duration of the Raman pulses is comparable to that of the pump pulses and is ~20 ns for the first Stokes components. The pulse in the third Stokes component is shorter by a factor of 2.5–3. Given the different pump levels and the differences in the thermallyinduced optical distortions of the Nd:KGW laser components, the energy density distribution for beams of the first Stokes components is elliptical, while that of the third Stokes components is almost circular. The possibility of simultaneous lasing at wavelengths of 1507 and 1538 nm with parallel and mutually orthogonal polarizations of the Stokes waves is demonstrated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Wear Mechanisms in Contacts Involving Slippers in Axial Piston Pumps: A Multi-Technical Analysis

Axial piston pumps are widely used in actuation as power conversion systems, especially in aeronautics. Even though they combine compactness and efficiency, wear of their parts reduces their lifespan. Studies on these pumps often consist in analytic or numerical analyses of lubricated contact between their components. Piston slippers are in tribological contacts with swashplate, pistons and slipper retainer. This study aims to understand wear mechanisms in the contacts involving this central component. An experimental multi-technical analysis of helicopter pumps parts after several functioning times is presented. To determine wear mechanisms, worn surfaces are observed with SEM. 3D surface roughness measurements provide surface topography. Contact conditions and consequently wear severity and mechanisms differ from one contact to another. Detached coarse carbides from the swashplate surface act as an abrading third-body against slippers and swashplate. Debris generated in this contact is carried by the fluid to the other contacts. Although pistons are made of the same steel as swashplate, there is no carbide detachment and wear comes from debris polluting the fluid. Slipper retainer is almost not worn, and debris causes abrasive wear and craters generation in the slippers.

36 MATERIALS SCIENCE↗

Lpp positions peptidoglycan at the AcrA-TolC interface in the AcrAB-TolC multidrug efflux pump

The multidrug efflux pumps of Gram-negative bacteria are a class of complexes that span the periplasm, coupling both the inner and outer membranes to expel toxic molecules. The best-characterized example of these tripartite pumps is the AcrAB-TolC complex of Escherichia coli. However, how the complex interacts with the peptidoglycan (PG) cell wall, which is anchored to the outer membrane (OM) by Braun’s lipoprotein (Lpp), is still largely unknown. In this work, we present molecular dynamics simulations of a complete, atomistic model of the AcrAB-TolC complex with the inner membrane, OM, and PG layers all present. We find that the PG localizes to the junction of AcrA and TolC, in agreement with recent cryo-tomography data. Free-energy calculations reveal that the positioning of PG is determined by the length and conformation of multiple Lpp copies anchoring it to the OM. The distance between the PG and OM measured in cryo-electron microscopy images of wild-type E. coli also agrees with the simulation-derived spacing. Finally, sequence analysis of AcrA suggests a conserved role for interactions with PG in the assembly and stabilization of efflux pumps, one that may extend to other trans-envelope complexes as well.

59 BASIC BIOLOGICAL SCIENCES↗

Experimental study of a tri-functional propane hydronic heat pump

This study investigates the performance of a propane hydronic heat pump system for space cooling, heating, and water heating applications, focusing on various operational conditions, with a total refrigerant charge below 1200 g. Cooling performance was evaluated at different outdoor temperatures, compressor stages (capacity levels), and water flow rates. The results showed that the coefficient of performance (COP) for cooling was higher at lower outdoor temperatures, with peak values exceeding 5.0 under low-stage operation and lower water flow rate. The cooling capacity increased with higher flow rates and compressor stages, reaching 12 kW. Space heating performance, evaluated at ambient temperatures ranging from −8.3 °C to 16.7 °C, revealed a decrease in COP with lower temperatures. However, high-stage operation maintained higher heating capacities even at low temperatures. The system demonstrated high Heating Seasonal Performance Factors (HSPF), exceeding 10.0. For water heating, the COP decreased with lower ambient temperatures and higher supply water temperatures. The system efficiently heated an 189-L water tank, outperforming conventional water heaters, with process COPs exceeding 4.0 under cooling-season conditions. Despite some efficiency loss due to defrosting at low temperatures, the propane heat pump consistently delivered strong performance. Seasonal energy efficiency ratios (SEER) and seasonal heating COP values indicated significant overall efficiency. The study concludes that propane is a promising refrigerant for heat pump systems, with future research needed to future reduce total system charge and optimize system performance through advanced controls and heat exchanger designs.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

From models to reality: a systematic review on simulated and measured residential heat pump energy savings

High-performance HVAC solutions are central to residential energy management. A substantial share of these are electric, reversible-cycle systems, with heat pumps representing the largest portion of current and near-term adoption. This review synthesizes peer-reviewed and grey literature on residential space heating and cooling heat pumps. The academic literature is dominated by modeling (73.8%), with limited field measurement (13.1%). Grey literature from United States serve as a supplemental resource providing measured savings. Conversions from electric-resistance heating consistently show the largest site energy reductions, while oil/propane baselines yield moderate savings, and gas baseline scenario often deliver small and region-dependent savings. This study cross-checks the grey literature measured data with simulation data filtered from the ResStock dataset. The comparison indicates a discrepancy between simulations and measured data: simulated site EUIs are typically lower than measured EUIs, but percentage energy savings fall in similar ranges, implying simulations capture directional effects while underestimating energy use. Factors associated with variability and model–measurement differences include system characterization and control representation (e.g., backup heat engagement, thermostat/setpoint strategies, commissioning/installation quality), occupant behavior, weather normalization, metering scope, and envelope characterization. This paper also outlines the proposed methodology for comparing simulation and measured data for heat pumps. It emphasizes the metrics used for comparison and units harmonization, building characteristics matching, and compact metadata are needed for simulations to match measured data. The proposed methodology is expected to improve the credibility of simulated savings as measured evidence grows.

Yu, Lili↗