Search NASA⌕ Search

SEARCH · Search NASA

Results for “PV module”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Solar Transposition Modeling via Deep Neural Networks With Sky Images

This article presents a notable advance toward the development of a new method of increasing the single-axis tracking photovoltaic (PV) system power output by improving the determination and near-term prediction of the optimum module tilt angle. The tilt angle of the plane receiving the greatest total irradiance changes with Sun position and atmospheric conditions including cloud formation and movement, aerosols, and particulate loading, as well as varying albedo within a module's field of view. In this article, we present a multi-input convolutional neural network that can create a profile of plane-of-array irradiance versus surface tilt angle over a full 180° arc from horizon to horizon. As input, the neural network uses the calculated solar position and clear-sky irradiance values, along with sky images. The target irradiance values are provided by the multiplanar irradiance sensor (MPIS). In order to account for varying irradiance conditions, the MPIS signal is normalized by the theoretical clear-sky global horizontal irradiance. Using this information, the neural network outputs an N -dimensional vector, where N is the number of points to approximate the MPIS curve via Fourier resampling. The output vector of the model is smoothed with a Gaussian kernel to account for error in the downsamping and subsequent upsampling steps, as well as to smooth the unconstrained output of the model. Furthermore, these profiles may be used to perform near-term prediction of angular irradiance, which can then inform the movement of a PV tracker.

42 ENGINEERING↗

Power Loss and Safety Risks - Recoverable vs. Non-Recoverable?

This presentation presents an update to the PV fleet analysis on PV system degradation. A median system degradation of -0.7 %/year was found for almost 5000 inverter traces. No significant difference between silicon and CdTe technologies were found. Systems with trackers showed a slightly higher degradation. Silicon technologies such as PERC and heterojunction showed degradation similar to conventional technologies but also showed different degradation mechanisms. To achieve long lifetimes early failure must be minimized through qualification testing. Rapid detection during normal life is important as is the control of bill of materials in modules.

degradation↗

Blind photovoltaic modeling intercomparison: A multidimensional data analysis and lessons learned

The Photovoltaic (PV) Performance Modeling Collaborative (PVPMC) organized a blind PV performance modeling intercomparison to allow PV modelers to blindly test their models and modeling ability against real system data. Measured weather and irradiance data were provided along with detailed descriptions of PV systems from two locations (Albuquerque, New Mexico, USA, and Roskilde, Denmark). Participants were asked to simulate the plane-of-array irradiance, module temperature, and DC power output from six systems and submit their results to Sandia for processing. The results showed overall median mean bias (i.e., the average error per participant) of 0.6% in annual irradiation and –3.3% in annual energy yield. While most PV performance modeling results seem to exhibit higher precision and accuracy as compared to an earlier blind PV modeling study in 2010, human errors, modeling skills, and derates were found to still cause significant errors in the estimates.

14 SOLAR ENERGY↗

Cohesive and adhesive degradation in PET-based photovoltaic backsheets subjected to ultraviolet accelerated weathering

Delamination between layers in photovoltaic (PV) backsheets is often reported in the literature, causing voids that can collect moisture, diminish module backside heat dissipation, and reduce the backsheet’s effectiveness as a physical barrier. While backsheets with weathering-resistant fluoropolymer outer layers have traditionally been used in modules, more recent backsheets using non-fluoropolymer outer layers, such as polyethylene terephthalate (PET), have been developed. These backsheets have shown signs of premature degradation, and their adhesion degradation, in particular, has not been widely studied. In the present work, the single cantilever beam (SCB) adhesion test was used to quantify the adhesion energy in two commercially available PET-based backsheets. To study the effect of minor changes in formulation, the backsheets were obtained from same manufacturer and product line but during different years. To study the effect of environmental variables on adhesion degradation, the backsheets were subjected to artificial weathering at controlled temperature, humidity, and ultraviolet (UV) radiation in an indoor weathering chamber, and the adhesion energy was quantified at several intervals of exposure time. Layering structure, composition, and adhesion failure mode were compared between the backsheets, using Raman and infrared spectroscopy and thermogravimetric analysis. The results show a large difference in initial (unexposed) adhesion energy between the backsheets, despite very similar structures and compositions. Following exposure, adhesion energy dropped significantly, primarily due to thermo-hydrolytic degradation of the polyurethane (PU)-based adhesive layers. Significant UV-induced adhesion degradation of the PET outer layer surface was also observed. The study represents an important step in understanding adhesion degradation in PET-based backsheets, suggesting ways in which adhesion integrity – and, correspondingly, module service life – can be improved.

14 SOLAR ENERGY↗

Temperature Coefficients of Perovskite Photovoltaics for Energy Yield Calculations

Temperature coefficients for maximum power (TPCE), open circuit voltage (VOC), and short circuit current (JSC) are standard specifications included in data sheets for any commercially available photovoltaic module. To date, there has been little work on determining the TPCE for perovskite photovoltaics (PV). We fabricate perovskite solar cells with a TPCE of -0.08 rel %/°C and then disentangle the temperature-dependent effects of the perovskite absorber, contact layers, and interfaces by comparing different device architectures and using drift-diffusion modeling. A main factor contributing to the small TPCE of perovskites is their low intrinsic carrier concentrations with respect to Si and GaAs, which can be explained by its wider band gap. In this work, we demonstrate that the unique increase in Eg with increasing temperatures seen for perovskites results in a reduction in JSC but positively influences VOC. The current limiting factors for the TPCE in perovskite PV are identified to originate from interfacial effects.

14 SOLAR ENERGY↗

Development of Fixtures and Methods to Assess the Durability of Balance of Systems Components

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were, therefore, examined, consisting of cable connector, branch connector, and discrete fuse components. In this study, unused field-vintage specimens are examined using a benchtop prototype fixture to identify the most influential environmental stressors on BoS components as well as the effect of external mechanical perturbation. The prototype fixture was used to develop a perturbation capability for future use in the combined-accelerated stress testing chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen current, voltage, and temperature. A significant increase in operating temperature (~100 °C from ~40 °C) and a different failure mode (arcing at the metal pins rather than overheating of the fuse filament) were observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (measured for static specimens, with failure occurring in the fuses) to 15 A (for tests with mechanical perturbation, with failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow for failure analysis, including the extraction of the internal convolute springs for morphological examination (optical and electron microscopy). Chemical composition analysis included energy-dispersive X-ray spectroscopy, differential scanning calorimetry, and Fourier transform infrared spectroscopy.

14 SOLAR ENERGY↗

Spatio-Temporal Denoising Graph Autoencoders with Data Augmentation for Missing Photovoltaic Data Imputation

The integration of the global Photovoltaic (PV) market with real time data-loggers has enabled large scale PV data analytical pipelines for power forecasting and long-term reliability assessment of PV fleets. Nevertheless, the performance of PV data analysis heavily depends on the quality of PV timeseries data. This paper proposes a novel Spatio-Temporal Denoising Graph Autoencoder (STD-GAE) framework to impute missing PV Power Data. STDGAE exploits temporal correlation, spatial coherence, and value dependencies from domain knowledge to recover missing data. It is empowered by two modules. (1) To cope with sparse yet various scenarios of missing data, STD-GAE incorporates a domain-knowledge aware data augmentation module that creates plausible variations of missing data patterns. This generalizes STD-GAE to robust imputation over different seasons and environment. (2) STD-GAE nontrivially integrates spatiotemporal graph convolution layers (to recover local missing data by observed “neighboring” PV plants) and denoising autoencoder (to recover corrupted data from augmented counterpart) to improve the accuracy of imputation accuracy at PV fleet level. We have evaluated our proposed model on two realworld PV datasets. Experimental results show that STD-GAE can achieve a gain of 43.14% in imputation accuracy and remains less sensitive to missing rate, different seasons, and missing scenarios, compared with state-of-the-art data imputation methods such as MIDA and LRTC-TNN.

Fan, Yangxin↗

The promise of metal-halide-perovskite solar photovoltaics: A brief review

Solar photovoltaics (PVs) based on metal-halide perovskites (MHPs) have taken the renewable-energy world by storm. The excitement stems from the promise of a high-efficiency, low-cost, and low “carbon-footprint” new PV technology. Here, a brief overview of the important topics pertaining to MHPs, perovskite solar cells (PSCs) and perovskite solar modules (PSMs) is presented. The topics include: (1) PSC architectures, (2) MHPs, (3) synthesis and processing of MHP thin films, (4) MHP thin-film microstructures, (5) PSC functional layers, (6) interfacial engineering in PSCs, (7) PSC performance, (8) PSC stability, (9) PSMs, (10) lead toxicity, and (11) mechanical behavior and reliability. The significant challenges in the path toward commercialization of this burgeoning PV technology are also highlighted. Chief among them are scalability, stability, reliability, and safety, while achieving high efficiency, low cost, and low “carbon-footprint.” Furthermore, the promise of this new PV technology and the fascinating underlying science make it a worthwhile endeavor to address these challenges.

14 SOLAR ENERGY↗

Numerical Validation of an Algorithm for Combined Soiling and Degradation Analysis of Photovoltaic Systems

We describe and demonstrate an open-source algorithm for simultaneously quantifying degradation and soiling of photovoltaic (PV) systems from energy-production time series data. The new analysis is based on year-on-year degradation rate analysis combined with stochastic rate and recovery soiling analysis. The algorithm is designed to fit into the workflow provided by RdTools, a Python module maintained by NREL and collaboratively developed with the community, which provides a framework and functions for degradation and loss-factor analysis of PV field data. We demonstrate the method on numerically simulated PV data sets and show that it reduces the root-mean-square error of the P50 degradation rate estimate when soiling is present.

14 SOLAR ENERGY↗

A Novel Approach to Thermal Design of Solar Modules: Selective-Spectral and Radiative Cooling

For commercial solar modules, up to 80% of the incoming sunlight may be dissipated as heat, potentially raising the temperature 20-30 degrees C higher than the ambient. In the long run, extreme self-heating may erode efficiency and shorten lifetime, thereby, dramatically reducing the total energy output by almost ~10% Therefore, it is critically important to develop effective and practical cooling methods to combat PV self-heating. In this paper, we explore two fundamental sources of PV self-heating, namely, sub-bandgap absorption and imperfect thermal radiation. The analysis suggests that we redesign the optical and thermal properties of the solar module to eliminate the parasitic absorption (selective-spectral cooling) and enhance the thermal emission to the cold cosmos (radiative cooling). The proposed technique should cool the module by ~10 degrees C, to be reflected in significant long-term energy gain (~ 3% to 8% over 25 years) for PV systems under different climatic conditions.

14 SOLAR ENERGY↗

Comparative Life Cycle Analysis of Scalable Single-Junction and Tandem Perovskite Solar Cell (PSC) Systems

Efficient, low-cost solar cells based upon perovskites have the potential to transform the US and global energy portfolio and improve energy security if they can be manufactured in an environmentally sustainable manner. However, previous life cycle analyses (LCA) of perovskite solar cells (PSC) used lab recipes to project the environmental impact of industrial PSC production – using materials and processes that may not be representative of industrial productions due to high material waste and complex synthesis – and such studies were limited to a few single-junction technologies. Thus, the goal of this project was threefold: a) to review the most promising for industrial production single-junction and tandem PSC technologies, b) to build life-cycle materials inventories that reflect scalable production of these technologies, and c) to conduct comprehensive life-cycle analysis of these technologies and compare their environmental impact with those of established commercial technologies. In response, this project identified challenges for fabrication transitioning from laboratory to sustainable industrial production, developed life-cycle inventory (LCI) data for scaling to industrial production four promising single-junction and three tandem PSC systems and produced life-cycle-investigations using, as metrics, a complete spectrum of energy, environmental and ecological impact indicators. Special focus was given to the use of lead, silver and indium in PSC. The project used the Life Cycle Assessment (LCA) methodology as standardized by the Society of Environmental Toxicology and Chemistry (SETAC), ISO standards 14040 and 14044, and the International Energy Agency PVPS Task 12 LCA guidelines. LCA allows the calculation of a number of energy and environmental and impact categories, including energy cumulative energy demand (CED), global warming potential (GWP), human toxicity potential (HTP), eco-toxicity potential (ETP), abiotic resource depletion potential (ADP), acidification potential (AP), ozone depletion potential (ODP), photochemical oxidation potential (POP), eutrophication potential (EP). In addition to those, we calculated the Energy Pay-Back Time (EPBT) and the Energy Return On Investment (EROI). We provide LCA impacts for complete perovskite PV systems – including balance of system components – installed at three irradiation levels and considering reference and future potential module efficiencies. Finally, a sensitivity analysis on perovskite lifetime has been performed, considering 10, 20 and 30 years. Contribution analysis of the impacts of each material and layer of PSC shows, that the use of Pb in metalorganic PSC does not result in significant environmental impacts as the major contributions to environmental indicators arise from the use of Ag and encapsulation materials. Solution-based PSC manufacturing was found to be less impactful to the environment than vapor-based fabrication, and roll-to-roll (RtR) printing uses less energy and generates the lowest emissions. PSC produced with RtR manufacturing could reach the same Energy Return on Energy Investment (EROI) as that of crystalline-Si PV within 12 years of life, whereas the most energy demanding spray coating on rigid substrates, would require a 20-yr life to match the EROI of 30-yr lasting silicon PV. This work lays the foundation for sustainability investigations in a comparative context of large-scale production and deployment of PSC. The results of this project have the potential to have a significant impact on the future of PV manufacturing, by providing industry, policy-makers, and academia with insights necessary to choose which, if any, lead-based solar cell life cycles are environmentally sustainable.

14 SOLAR ENERGY↗

PV degradation curves: non‐linearities and failure modes

Abstract Photovoltaic (PV) reliability and durability have seen increased interest in recent years. Historically, and as a preliminarily reasonable approximation, linear degradation rates have been used to quantify long‐term module and system performance. The underlying assumption of linearity can be violated at the beginning of the life, as has been well documented, especially for thin‐film technology. Additionally, non‐linearities in the wear‐out phase can have significant economic impact and appear to be linked to different failure modes. In addition, associating specific degradation and failure modes with specific time series behavior will aid in duplicating these degradation modes in accelerated tests and, eventually, in service life prediction. In this paper, we discuss different degradation modes and how some of these may cause approximately linear degradation within the measurement uncertainty (e.g., modules that were mainly affected by encapsulant discoloration) while other degradation modes lead to distinctly non‐linear degradation (e.g., hot spots caused by cracked cells or solder bond failures and corrosion). The various behaviors are summarized with the goal of aiding in predictions of what may be seen in other systems. Published 2016. This article is a U.S. Government work and is in the public domain in the USA.

Jordan, Dirk C.↗

Assessing the Impacts of Extreme Weather Events on Photovoltaic Installations Using Remote Sensing Imagery

In this study, we analyze poststorm satellite imagery to assess solar photovoltaic (PV) damage for over 11,300 systems following a catastrophic hailstorm in Austin, TX, in September 2023, which produced softball‐sized hail and for over 1500 systems across Puerto Rico and the US Virgin Islands after Hurricanes Irma and Maria in September 2017. Findings show that approximately 5.5% of identified PV sites were damaged in the hailstorm and approximately 17% of PV installations were damaged after the hurricanes. A weak correlation between hurricane wind gust speed and percent site damage was determined, with installation practices playing a heavy role in site resilience. Additionally, we show that newer module vintages are more susceptible to hail damage than older modules, possibly due to a convergence of larger size modules, decreased frame dimensions, and decreased front glass thickness but more research is needed. For hail sizes of 60 mm or greater, consistent hail damage is sustained by PV installations, regardless of system configuration.

14 SOLAR ENERGY↗

Topics in electrochemical degradation of photovoltaic modules

Electrochemical degradation of photovoltaic modules was examined. It is found that the extent of electrochemical damage is dependent on the integrated leakage current. The PV electrochemical degradation mechanisms in the two polarities are different: (1) degradation rates in the two polarities are of the same order of magnitude; (2) center tapped grounded arrays are a preferred system configuration to minimize electrochemical degradation. The use of thicker pottant layers and polymer substrate films to reduce equilibrium leakage current values is suggested. A metallized substrate layer, if used, should be isolated from the pottant and the frame by polyester layers, and EVA modules appear to be consistent with 30 year life allocation levels for electrochemical damage. Temperature acceleration factors are well behaved and moderately well understood; humidity acceleration factors vary radically with module construction and materials and require additional research.

Mon, G. R.↗

Embodied energy and carbon from the manufacture of cadmium telluride and silicon photovoltaics

Here, looking beyond the traditional cost and efficiency metrics of photovoltaics (PV), this work evaluates the impact of embodied energy, embodied carbon, and energy payback time of two dominant technologies (CdTe and Si) on global decarbonization goals. The relative effects of PV technology type, technological advances, energy grid mix, and recycling are evaluated in terms of fostering decarbonization goals. If the highest carbon-intensity scenarios are realized, 2%-14% of the remaining estimated global carbon budget might be consumed to manufacture modules without including their balance of systems. Applying a carbon cost indicates that CdTe might have an additional value of $\$$0.02-$\$$0.04/W relative to Si PV manufactured with the same energy mix. Due to the scale of the challenge, any actions leading to an increased deployment of thin-film PV and/or a significant decrease in the deployed PV's embodied carbon through changing the manufacturing grid mix have demonstrable value in helping the world stay within its remaining estimated carbon budget.

14 SOLAR ENERGY↗

Prioritizing circular economy strategies for sustainable PV deployment at the TW scale

Global decarbonization requires an unprecedented scale-up of photovoltaic (PV) manufacturing and deployment. The material demand and eventual end of life management associated with multi-TW scale deployment poses many challenges. Circular Economy (CE) and it's associated R-Actions (Reduce, Reuse, Recycle) have been proposed to mitigate end of life management and material sourcing concerns. However, CE metrics typically focus on a single product and only consider mass, excluding energy flows. This work leverages the PV in Circular Economy (PV ICE) tool to quantify the deployment, mass, and energy impacts of R-Actions and proposed sustainable PV designs in the context of achieving energy transition deployment goals (75 TW in 2050). 13 module scenarios are established and evaluated across 6 capacity, mass and energy metrics to identify tradeoffs and priorities. We find that increasing module efficiency can reduce near-term material demands up to 30% and improve energy metrics by up to 9%. Material circularity (recycling) can minimize lifecycle wastes and reduce material demands at the cost of higher energy demands. Increasing module lifetime, including reliability improvements and reuse strategies, is effective at reducing both material (>10%) and energy demands (24%). Uniquely, lifetime improvements maximize benefits and minimize the harms across all six metrics while achieving multi-TW scale deployment.

Photovoltaics↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. In this study, unused field-vintage specimens are examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for the C-AST chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen current, voltage, and temperature. A significant increase in operating temperature (~100 degrees C from ~40 degrees C) and a different failure mode were observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow for failure analysis, including the extraction of the internal convolute springs for morphological examination (optical and electron microscopy).

balance of systems↗

Determination of tire cross-sectional geometric characteristics from a digitally scanned image

A semi-automated procedure is described for the accurate determination of geometrical characteristics using a scanned image of the tire cross-section. The procedure can be useful for cases when CAD drawings are not available or when a description of the actual cured tire is desired. Curves representing the perimeter of the tire cross-section are determined by an edge tracing scheme, and the plyline and cord-end positions are determined by locations of color intensities. The procedure provides an accurate description of the perimeter of the tire cross-section and the locations of plylines and cord-ends. The position, normals, and curvatures of the cross-sectional surface are included in this description. The locations of the plylines provide the necessary information for determining the ply thicknesses and relative position to a reference surface. Finally, the locations of the cord-ends provide a means to calculate the cord-ends per inch (epi). Menu driven software has been developed to facilitate the procedure using the commercial code, PV-Wave by Visual Numerics, Inc., to display the images. From a single user interface, separate modules are executed for image enhancement, curve fitting the edge trace of the cross-sectional perimeter, and determining the plyline and cord-end locations. The code can run on SUN or SGI workstations and requires the use of a mouse to specify options or identify items on the scanned image.

Danielson, Kent T.↗