Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Deviation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Isomeric effects on the reactivity of branched alkenes: An experimental and kinetic modeling study of methylbutenes

Here, a detailed experimental study of the low-to-intermediate temperature combustion of methylbutene isomers, i.e., branched C 5 alkenes, has been undertaken with multiple experimental facilities. Ignition delay times were measured at equivalence ratios 0.5–2.0, 685–1020 K and up to 45 bar condition from two rapid compression machines and showed slight deviation from an Arrhenius behavior for all three isomers, while their reactivity order differs as temperature changes. Sampled intermediates formed during the oxidation process of mixtures at 900–1150 K and 0.82 bar from a flow reactor and at 730 K and 20 bar from a rapid compression machine were analyzed using gas chromatography techniques. Trends in the formation and consumption of sampled intermediates were modeled using a kinetic model developed in this work for all three isomers. Rate of production and sensitivity analyses emphasize the role of double bond-specific reactions governing the global reactivity of these fuels. Additional studies of the addition reactions of HO 2 radicals to the double bond and to allylic radicals may improve the model performance.

2-Methyl-1-butene↗

Search for the associated production of the Higgs boson and a vector boson in proton-proton collisions at $ \sqrt{s} $ = 13 TeV via Higgs boson decays to τ leptons

A search for the standard model Higgs boson, decaying to a pair of $\tau$ leptons and produced in association with a W or a Z boson is performed. A data sample of proton-proton collisions collected at $\sqrt{s} =$ 13 TeV by the CMS experiment at the CERN LHC is used, corresponding to an integrated luminosity of 35.9 fb$^{-1}$. The signal strength is measured relative to the expectation for the standard model Higgs boson, yielding $\mu =$ 2.5$^{+1.4} _{-1.3}$. These results are combined with earlier CMS measurements targeting Higgs boson decays to a pair of $\tau$ leptons, performed with the same data set in the gluon fusion and vector boson fusion production modes. The combined signal strength is $\mu =$ 1.24$ ^{+0.29} _{-0.27}$ (1.00$^{+0.24} _{-0.23}$ expected), and the observed significance is 5.5 standard deviations (4.8 expected) for a Higgs boson mass of 125 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a plasma generator for a long pulse ion source for neutral beam injectors

A plasma generator for a long pulse H{sup +}/D{sup +} ion source has been developed. The plasma generator was designed to produce 65 A H{sup +}/D{sup +} beams at an energy of 120 keV from an ion extraction area of 12 cm in width and 45 cm in length. Configuration of the plasma generator is a multi-cusp bucket type with SmCo permanent magnets. Dimension of a plasma chamber is 25 cm in width, 59 cm in length, and 32.5 cm in depth. The plasma generator was designed and fabricated at Japan Atomic Energy Agency. Source plasma generation and beam extraction tests for hydrogen coupling with an accelerator of the KSTAR ion source have been performed at the KSTAR neutral beam test stand under the agreement of Japan-Korea collaborative experiment. Spatial uniformity of the source plasma at the extraction region was measured using Langmuir probes and {+-}7% of the deviation from an averaged ion saturation current density was obtained. A long pulse test of the plasma generation up to 200 s with an arc discharge power of 70 kW has been successfully demonstrated. The arc discharge power satisfies the requirement of the beam production for the KSTAR NBI. A 70 keV, 41 A, 5 s hydrogen ion beam has been extracted with a high arc efficiency of 0.9 -1.1 A/kW at a beam extraction experiment. A deuteron yield of 77% was measured even at a low beam current density of 73 mA/cm{sup 2}.

43 PARTICLE ACCELERATORS↗

Search for the production of W±W±W events at s =13 TeV

A search for the production of events containing three W bosons predicted by the standard model is reported. The search is based on a data sample of proton-proton collisions at a center-of-mass energy of 13 TeV recorded by the CMS experiment at the CERN LHC and corresponding to a total integrated luminosity of 35.9 fb-1. The search is performed in final states with three leptons (electrons or muons), or with two same-charge leptons plus two jets. The observed (expected) significance of the signal for W±W±W production is 0.60 (1.78) standard deviations, and the ratio of the measured signal yield to that expected from the standard model is 0.34-0.34+0.62. Limits are placed on three anomalous quartic gauge couplings and on the production of massive axionlike particles.

60 APPLIED LIFE SCIENCES↗

Calibration of helical tomotherapy machine using EPR/alanine dosimetry

Purpose: Current codes of practice for clinical reference dosimetry of high-energy photon beams in conventional radiotherapy recommend using a 10x10 cm{sup 2} square field, with the detector at a reference depth of 10 cm in water and 100 cm source to surface distance (SSD) (AAPM TG-51) or 100 cm source-to-axis distance (SAD) (IAEA TRS-398). However, the maximum field size of a helical tomotherapy (HT) machine is 40x5 cm{sup 2} defined at 85 cm SAD. These nonstandard conditions prevent a direct implementation of these protocols. The purpose of this study is twofold: To check the absorbed dose in water and dose rate calibration of a tomotherapy unit as well as the accuracy of the tomotherapy treatment planning system (TPS) calculations for a specific test case. Method: Both topics are based on the use of electron paramagnetic resonance (EPR) using alanine as transfer dosimeter between the Laboratoire National Henri Becquerel (LNHB) {sup 60}Co-{gamma}-ray reference beam and the Institut Curie's HT beam. Irradiations performed in the LNHB reference {sup 60}Co-{gamma}-ray beam allowed setting up the calibration method, which was then implemented and tested at the LNHB 6 MV linac x-ray beam, resulting in a deviation of 1.6% (at a 1% standard uncertainty) relative to the reference value determined with the standard IAEA TRS-398 protocol. Results: HT beam dose rate estimation shows a difference of 2% with the value stated by the manufacturer at a 2% standard uncertainty. A 4% deviation between measured dose and the calculation from the tomotherapy TPS was found. The latter was originated by an inadequate representation of the phantom CT-scan values and, consequently, mass densities within the phantom. This difference has been explained by the mass density values given by the CT-scan and used by the TPS which were not the true ones. Once corrected using Monte Carlo N-Particle simulations to validate the accuracy of this process, the difference between corrected TPS calculations and alanine measured dose values was then found to be around 2% (with 2% standard uncertainty on TPS doses and 1.5% standard uncertainty on EPR measurements). Conclusion: Beam dose rate estimation results were found to be in good agreement with the reference value given by the manufacturer at 2% standard uncertainty. Moreover, the dose determination method was set up with a deviation around 2% (at a 2% standard uncertainty).

61 RADIATION PROTECTION AND DOSIMETRY↗

TU-AB-BRC-06: Dose Calculation in Curved Space

Purpose: Microbeam Radiation Therapy is a preclinical method in radiation oncology that modulates radiation fields on a micrometre scale. Dose calculation is challenging due to arising dose gradients and therapeutically important dose ranges. Monte Carlo (MC) simulations, often used as gold standard, are computationally expensive and hence too slow for the optimisation of treatment parameters in future clinical applications. On the other hand, conventional kernel based dose calculation leads to inaccurate results close to material interfaces. The purpose of this work is to overcome these inaccuracies while keeping computation times low. Methods: A point kernel superposition algorithm is modified to account for tissue inhomogeneities. Instead of conventional ray tracing approaches, methods from differential geometry are applied and the space around the primary photon interaction is locally warped. The performance of this approach is compared to MC simulations and a simple convolution algorithm (CA) for two different phantoms and photon spectra. Results: While peak doses of all dose calculation methods agreed within less than 4% deviations, the proposed approach surpassed a simple convolution algorithm in accuracy by a factor of up to 3 in the scatter dose. In a treatment geometry similar to possible future clinical situations differences between Monte Carlo and the differential geometry algorithm were less than 3%. At the same time the calculation time did not exceed 15 minutes. Conclusion: With the developed method it was possible to improve the dose calculation based on the CA method with respect to accuracy especially at sharp tissue boundaries. While the calculation is more extensive than for the CA method and depends on field size, the typical calculation time for a 20×20 mm{sup 2} field on a 3.4 GHz and 8 GByte RAM processor remained below 15 minutes. Parallelisation and optimisation of the algorithm could lead to further significant calculation time reductions.

60 APPLIED LIFE SCIENCES↗

Data Locality Enhancement of Dynamic Simulations for Exascale Computing (Final Report)

The development of modern processors exhibits two trends that complicate the optimizations of modern software. The first is the increasing sensitivity of processors' throughput to irregularities in computation. With more processors produced through a massive integration of simple cores, future systems will increasingly favor regular data-level parallel computations, but deviate from the needs of applications with complex patterns. Some evidences are already shown on Graphic Processing Units (GPU): Irregular data accesses (e.g., indirect references A[D[i]]) and conditional branches are limiting many GPU applications' performance at a level an order of magnitude lower than the peak of GPU. The second hardware trend is the growing gap between memory bandwidth and the aggregate speed—that is, the sum of all cores' computing power—of a Chip Multiprocessor (CMP). Despite the capped growth of the peak CPU speed, the aggregate speed of a CMP keeps increasing as more cores get into a single chip. It is expected that by 2018, node concurrency in an exascale system will increase by hundreds of times, whereas, memory bandwidth will expand by only 10 to 20 times. Consequently, data movement and storage is expected to consume more than 70% of the total system power. Bridging this gap is difficult; the complexities of modern CMP memory hierarchy make it even harder: Data cache becomes shared among computing units, and the sharing is often non-uniform—whether two computing units share a cache depends on their proximity and the level of the cache. On the recent IBM Power7 architecture, for instance, four hardware contexts (or SMT threads) in a core share the entire memory hierarchy, all cores in one chip share an on-chip L3 cache, and cores across chips share L3 and main memory through off-chip connections. These two trends complicate the translation of computing power into performance, especially for a program with either intensive data accesses or complex patterns in data accesses or control flow paths. Unfortunately, both attributes present and will persist in a class of important applications. For instance, many scientific simulations deal with a large volume of data. And meanwhile, as most real-world processes are non-uniform and evolving (e.g., the evolution of a galaxy or the process of a drug injection), both the computations and data accesses of these programs tend to be irregular and dynamically changing. Currently, the lack of support to these applications on modern CMP severely limits their performance. On GPU, as our recent study shows and other studies echo, performance enhancement of a factor of integers is possible when memory accesses or control flows are streamlined for a set of GPU applications. On multicore CPU, our studies show that traditional locality enhancement, for being oblivious to the new features of multicore memory hierarchy, may even cause large slowdown to data-intensive dynamic applications. The severity of the issues is expected to worsen as the two hardware trends continue. Some recent studies try to match software with the trends, but in a limited scope or manner. For irregularities on GPU, most studies focus on irregularities analyzable through static analysis (e.g., data accesses in regular loops). Dynamic irregularities are harder to address because the needed analysis and transformations typically have to happen at run time. Some other research resorts to hardware extensions, an actual adoption of which is unclear for the entailed space cost and complexity. For data locality, recent years have seen some exploitations of the new memory hierarchy on multicore for performance, but most of them are on process or thread scheduling, rather than program transformations. Our recent study reveals that program-level transformations may magnify the scheduling benefits by a factor of seven, concluding that program-level transformation should play a central role for data locality enhancement on modern CMP. But research in this direction has been sparse, and most have focused on data layout or cache performance modeling, rather than program transformations to match with the new memory hierarchy features. Overall, it is still an open question how to bridge the gap between dynamic computations and the two prominent properties of modern processors. The goal of this project is to develop a set of techniques and software tools to enhance the matching between memory accesses in dynamic simulations and the prominent features of modern and future CMP, alleviating the memory performance issues for petascale and exascale computing. This report summarizes the discoveries and products produced throughout this project. It includes free launch, a new software approach to overcoming the shortcomings of both methods; coherence-free multiview, an approach that allows multiple views of a single data object to co-exist on GPU memory during a GPU kernel execution; algorithmic optimizations to data analytics problems, especially those that involve lots of distance calculations. Supporting dynamic parallelism is important for GPU to benefit a broad range of applications. There are currently two fundamental ways for programs to exploit dynamic parallelism on GPU: a software-based approach with software-managed worklists, and a hardware-based approach through dynamic subkernel launches. Neither is satisfactory. The former is complicated to program and is often subject to some load imbalance; the latter suffers large runtime overhead. In this work, we propose free launch, a new software approach to overcoming the shortcomings of both methods. It allows programmers to use subkernel launches to express dynamic parallelism. It employs a novel compiler-based code transformation named subkernel launch removal to replace the subkernel launches with the reuse of parent threads. Coupled with an adaptive task assignment mechanism, the transformation reassigns the tasks in the subkernels to the parent threads with a good load balance. The technique requires no hardware extensions, immediately deployable on existing GPUs. It keeps the programming convenience of the subkernel launch-based approach while avoiding its large runtime overhead. Meanwhile, its superior load balancing makes it outperform manual worklist-based techniques by 3X on average. The work was published at the 48th Annual IEEE/ACM International Symposium on Microarchitecture (Micro'2015). A Graphic Processing Unit (GPU) system is typically equipped with many types of memory (e.g., global, constant, texture, shared, cache). Data placement determines what data are placed on which type of memory, essential for GPU memory performance. Prior optimizations of data placement always require a single view of a data object on memory, which limits the optimization effectiveness. In this work, we propose coherence-free multiview, an approach that allows multiple views of a single data object to co-exist on GPU memory during a GPU kernel execution. We demonstrate that under certain conditions, the multiple views can remain incoherent while facilitating enhanced data placement. We present a theorem and some compiler support to ensure the soundness of the usage of coherence-free multiview. We further develop reference-discerning data placement, a new way to enhance data placements on GPU. It enables more flexible data placements by using coherence-free multiview to leverage the slack in coherence requirement of some GPU programs. Experiments on three types of GPU systems show that, with less than 200KB space cost, the new data placement technique can provide a 1.6X average (up to 4.27X) speedup. In addition, we have examined algorithmic optimizations to data analytics problems, especially those that involve lots of distance calculations. Computing distances among data points is an essential part of many important algorithms in data analytics, graph analysis, and other domains. In each of these domains, developers have spent significant manual effort optimizing algorithms, often through novel applications of the triangle equality, in order to minimize the number of distance computations in the algorithms. In this work, we observe that many algorithms across these domains can be generalized as an instance of a generic distance-related abstraction. Based on this abstraction, we derive seven principles for correctly applying the triangular inequality to optimize distance-related algorithms. Guided by the findings, we develop Triangular OPtimizer (TOP), the first software framework that is able to automatically produce optimized algorithms that either matches or outperforms manually designed algorithms for solving distance-related problems. TOP achieves up to 237x speedups and 2.5X on average. The work has been published at the 32nd International Conference on Machine Learning (ICML'15) and the 41st International Conference on Very Large Data Bases (VLDB'15).

42 ENGINEERING↗

Advanced Safeguards Technology Demonstration at Pacific Northwest National Laboratory

The IAEA has established international safeguards standards for fissionable materials at spent fuel reprocessing plants to ensure that significant quantities of weapons-grade nuclear material are not diverted over a specified time frame. It is, therefore, necessary to confirm proper operational performance to verify facilities operate under adequate safeguard-declared conditions. This verification can be achieved by employing monitoring equipment. Online real time monitoring of the flowsheet radiochemical streams provides a unique capability to rapidly identify deviations from normal operating conditions. Flowsheet monitoring technologies being developed at PNNL include three integrated systems: Multi-Isotope Process (MIP) Monitor, spectroscopy-based monitor (UV-vis-NIR and Raman spectrometers), and Electrochemically Modulated Separations (EMS). The MIP Monitor is designed to identify off-normal conditions in process streams using gamma spectroscopy and pattern recognition software. The spectroscopic monitoring continuously measures chemical compositions of the process streams including actinide metal ions (U, Pu, Np), selected fission products, and major cold flowsheet chemicals. EMS provides an on-line means for pre-separating and pre-concentrating elements of interest out of complex matrices prior to detection. PNNL is preparing to test these multi-parametric technologies using different samples of dissolved spent fuel and aqueous and organic phases of the PUREX and UREX flowsheets. We will report our on-going efforts with specific focus given to quantifying sensitivity of the MIP Monitor and UV-Vis and Raman spectrometers to detect minor changes in major process variables.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cross Section Measurement for the 95Mo(n, {alpha})92Zr Reaction at 4.0, 5.0 and 6.0 MeV

For the {sup 95}Mo(n, {alpha}){sup 92}Zr reaction cross section, there is only one experimental datum in the MeV neutron energy region with large uncertainty. As a result, very large deviations exist in different evaluated nuclear data libraries. This paper report the measurement of cross sections of the {sup 95}Mo(n, {alpha}){sup 92}Zr reaction at En = 4.0, 5.0 and 6.0 MeV. Experiments were performed at the 4.5 MV Van de Graaff of Peking University, China. A twin gridded ionization chamber was used as alpha particle detector and two large area {sup 95}Mo samples placed back to back were adopted. Fast neutrons were produced through the D(d, n){sup 3}He reaction by using a deuterium gas target. A small {sup 238}U fission chamber was adopted for absolute neutron flux determination and a BF{sub 3} long counter was used for neutron flux monitor. Present experimental data are compared with existing evaluations and measurement.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effect of double heterogeneity treatment on neutronics modeling of HTGR unit cell - 18524

The High Temperature Gas-cooled Reactor (HTGR) utilizes unique coated fuel particle design, which is embedded within a graphite matrix and shaped into spherical or hexagonal fuel element. The feature of the inherent double heterogeneity in the HTGR fuel element therefore raises difficulties in modeling and requires special simulation strategies to address its impact on the self-shielding calculation. In this study, neutronics calculations with various levels of heterogeneity processing were performed for both spherical and hexagonal HTGR fuel elements. The results indicate that ignoring either level of double heterogeneity can lead to significant underestimation of self-shielding effect and consequently yield as much as 8% deviation in the prediction of the multiplication factor. Fission and capture rates were compared for the spherical HTGR fuel model and over 30% deviation was found in the resonance energy range if homogenized model used. Further investigation on the neutron spectrum demonstrated similar tendency for both types of fuel elements when applying the simplified self-shielding models, that is, {approx}20% underestimation of neutron flux in 6.5-6.75 eV energy interval was observed due to the incomplete evaluation of the cross section resonance self-shielding effect. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Monte Carlo Simulations of the Dissolution of Borosilicate Glasses in Near-Equilibrium Conditions

Monte Carlo simulations were performed to investigate the mechanisms of glass dissolution as equilibrium conditions are approached in both static and flow-through conditions. The glasses studied are borosilicate glasses in the compositional range (80-x)% SiO2 (10+x/2)% B2O3 (10+x/2)% Na2O, where 5 < x < 30%. In static conditions, dissolution/condensation reactions lead to the formation, for all compositions studied, of a blocking layer composed of polymerized Si sites with principally 4 connections to nearest Si sites. This layer forms atop the altered glass layer and shows similar composition and density for all glass compositions considered. In flow-through conditions, three main dissolution regimes are observed: at high flow rates, the dissolving glass exhibits a thin alteration layer and congruent dissolution; at low flow rates, a blocking layer is formed as in static conditions but the simulations show that water can occasionally break through the blocking layer causing the corrosion process to resume; and, at intermediate flow rates, the glasses dissolve incongruently with an increasingly deepening altered layer. The simulation results suggest that, in geological disposal environments, small perturbations or slow flows could be enough to prevent the formation of a permanent blocking layer.

borosilicate glasses↗

Study of (W/Z)H production and Higgs boson couplings using H→ W W * decays with the ATLAS detector

A search for Higgs boson production in association with a W or Z boson, in the H→ W W * decay channel, is performed with a data sample collected with the ATLAS detector at the LHC in proton-proton collisions at centre-of-mass energies \( \sqrt{s}=7 \) TeV and 8 TeV, corresponding to integrated luminosities of 4.5 fb -1 and 20.3 fb -1 , respectively. The WH production mode is studied in two-lepton and three-lepton final states, while two- lepton and four-lepton final states are used to search for the ZH production mode. The observed significance, for the combined W H and ZH production, is 2.5 standard deviations while a significance of 0.9 standard deviations is expected in the Standard Model Higgs boson hypothesis. The ratio of the combined W H and ZH signal yield to the Standard Model expectation, μ V H , is found to be μ V H = 3.0 -1.1 +1.3 (stat.) -0.7 +1.0 (sys.) for the Higgs boson mass of 125.36 GeV. The W H and ZH production modes are also combined with the gluon fusion and vector boson fusion production modes studied in the H → W W * → ℓνℓν decay channel, resulting in an overall observed significance of 6.5 standard deviations and μ ggF + VBF + VH = 1.16 -0.15 +0.16 (stat.) -0.15 +0.18 (sys.). The results are interpreted in terms of scaling factors of the Higgs boson couplings to vector bosons (κ V ) and fermions (κ F ); the combined results are: |κ V | = 1.06 -0.10 +0.10 , |κ F | = 0.85 -0.20 +0.26 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A stochastic wind turbine wake model based on new metrics for wake characterization

Abstract Understanding the detailed dynamics of wind turbine wakes is critical to predicting the performance and maximizing the efficiency of wind farms. This knowledge requires atmospheric data at a high spatial and temporal resolution, which are not easily obtained from direct measurements. Therefore, research is often based on numerical models, which vary in fidelity and computational cost. The simplest models produce axisymmetric wakes and are only valid beyond the near wake. Higher‐fidelity results can be obtained by solving the filtered Navier–Stokes equations at a resolution that is sufficient to resolve the relevant turbulence scales. This work addresses the gap between these two extremes by proposing a stochastic model that produces an unsteady asymmetric wake. The model is developed based on a large‐eddy simulation (LES) of an offshore wind farm. Because there are several ways of characterizing wakes, the first part of this work explores different approaches to defining global wake characteristics. From these, a model is developed that captures essential features of a LES‐generated wake at a small fraction of the cost. The synthetic wake successfully reproduces the mean characteristics of the original LES wake, including its area and stretching patterns, and statistics of the mean azimuthal radius. The mean and standard deviation of the wake width and height are also reproduced. This preliminary study focuses on reproducing the wake shape, while future work will incorporate velocity deficit and meandering, as well as different stability scenarios. Copyright © 2016 John Wiley & Sons, Ltd.

Doubrawa, Paula↗

A novel lateral disequilibrium inclusive (LDI) pencil-beam based dose calculation algorithm: Evaluation in inhomogeneous phantoms and comparison with Monte Carlo calculations

Purpose: Pencil-beam (PB) based dose calculation for treatment planning is limited by inaccuracies in regions of tissue inhomogeneities, particularly in situations with lateral electron disequilibrium as is present at tissue/lung interfaces. To overcome these limitations, a new ''lateral disequilibrium inclusive'' (LDI) PB based calculation algorithm was introduced. In this study, the authors evaluated the accuracy of the new model by film and ionization chamber measurements and Monte Carlo simulations. Methods: To validate the performance of the new LDI algorithm implemented in Corvus 09, eight test plans were generated on inhomogeneous thorax and pelvis phantoms. In addition, three plans were calculated with a simple effective path length (EPL) algorithm on the inhomogeneous thorax phantom. To simulate homogeneous tissues, four test plans were evaluated in homogeneous phantoms (homogeneous dose calculation). Results: The mean pixel pass rates and standard deviations of the gamma 4%/4 mm test for the film measurements were (96{+-}3)% for the plans calculated with LDI, (70{+-}5)% for the plans calculated with EPL, and (99{+-}1)% for the homogeneous plans. Ionization chamber measurements and Monte Carlo simulations confirmed the high accuracy of the new algorithm (dose deviations {<=}4%; gamma 3%/3 mm {>=}96%)Conclusions: LDI represents an accurate and fast dose calculation algorithm for treatment planning.

60 APPLIED LIFE SCIENCES↗

Controlled growth of ZnO nanorods on textured silicon wafer and the application for highly effective and recyclable SERS substrate by decorating Ag nanoparticles

Highlights: • The growth behavior of ZnO nanorods (NRs) is studied on the textured Si wafer. • A new surface-enhanced Raman scattering (SERS) substrate has been achieved by assembling Ag nanoparticles onto the ZnO NRs. • The SERS substrate exhibits good performance in terms of high sensitivity, good reproducibility and recyclability. - Abstract: Based on the study of growth behavior of ZnO nanorods on the textured Si wafer, a new three-dimensional surface-enhanced Raman scattering substrate has been achieved by assembling Ag nanoparticles onto the ZnO nanorods to form a radial plasmonic nanostructure. It is found that the new substrate exhibits good performance in terms of high sensitivity and good reproducibility for surface-enhanced Raman scattering. The determined enhancement factor is in the order of 10{sup 7} and the Raman spectra exhibit the remarkable consistency with the deviation below 5.0%. Compared to the substrate fabricated with ZnO nanorod array on the flat Si wafer, the new substrates have the higher utility of excitation light. Meanwhile, the new substrate is demonstrated to be recyclable after the irradiation of ultraviolet light.

36 MATERIALS SCIENCE↗

Benchmark Calculations of Energetic Properties of Groups 4 and 6 Transition Metal Oxide Nanoclusters Including Comparison to Density Functional Theory

The heats of formation and the normalized clustering energies (NCEs) for the group 4 and group 6 transition metal oxide (TMO) trimers and tetramers have been calculated by the Feller-Peterson-Dixon (FPD) method. The heats of formation predicted by the FPD method do not differ much from those previously derived from the NCEs at the CCSD(T)/aT level except for the CrO3 nanoclusters. New and improved heats of formation for Cr3O9 and Cr4O12 were obtained using PW91 orbitals instead of Hartree-Fock (HF) orbitals. Diffuse functions are necessary to predict accurate heats of formation. The fluoride affinities (FAs) are calculated with the CCSD(T) method. The relative energies (REs) of different isomers, NCEs, electron affinities (EAs), and FAs of (MO2)n ( M = Ti, Zr, Hf, n = 1 – 4 ) and (MO3)n ( M = Cr, Mo, W, n = 1 – 3) clusters have been benchmarked with 55 exchange-correlation DFT functionals including both pure and hybrid types. The absolute errors of the DFT results are mostly less than ±10 kcal/mol for the NCEs and the EAs, and less than ±15 kcal/mol for the FAs. Hybrid functionals usually perform better than the pure functionals for the REs and NCEs. The performance of the two types of functionals in predicting EAs and FAs is comparable. The B1B95 and PBE1PBE functionals provide reliable energetic properties for most isomers. Long range corrected pure functionals usually give poor FAs. The standard deviation of the absolute error is always close to the mean errors and the probability distributions of the DFT errors are often not Gaussian (normal). The breadth of the distribution of errors and the maximum probability are dependent on the energy property and the isomer.

Environmental Molecular Sciences Laboratory↗

Voltage Mining for (De)lithiation-Stabilized Cathodes and a Machine Learning Model for Li-Ion Cathode Voltage

Advances in lithium-metal anodes have inspired interest in discovery of Li-free cathodes, most of which are natively found in their charged state. This is in contrast to today's commercial lithium-ion battery cathodes, which are more stable in their discharged state. In this study, we combine calculated cathode voltage information from both categories of cathode materials, covering 5577 and 2423 total unique structure pairs, respectively. The resulting voltage distributions with respect to the redox pairs and anion types for both classes of compounds emphasize design principles for high-voltage cathodes, which favor later Period 4 transition metals in their higher oxidation states and more electronegative anions like fluorine or polyanion groups. Generally, cathodes that are found in their charged, delithiated state are shown to exhibit voltages lower than those that are most stable in their lithiated state, in agreement with thermodynamic expectations. Deviations from this trend are found to originate from different anion distributions between redox pairs. In addition, a machine learning model for voltage prediction based on chemical formulas is trained and shows state-of-the-art performance when compared to two established composition-based ML models for material properties predictions, Roost and CrabNet.

25 ENERGY STORAGE↗

Phase Contrast Imaging with Coded Apertures Using Laboratory-Based X-ray Sources

X-ray phase contrast imaging is a powerful technique that allows detection of changes in the phase of x-ray wavefronts as they pass through a sample. As a result, details not visible in conventional x-ray absorption imaging can be detected. Until recently the majority of applications of phase contrast imaging were at synchrotron facilities due to the availability of their high flux and coherence; however, a number of techniques have appeared recently that allow phase contrast imaging to be performed using laboratory sources. Here we describe a phase contrast imaging technique, developed at University College London, that uses two coded apertures. The x-ray beam is shaped by the pre-sample aperture, and small deviations in the x-ray propagation direction are detected with the help of the detector aperture. In contrast with other methods, it has a much more relaxed requirement for the source size (it works with source sizes up to 100 {mu}m). A working prototype coded-aperture system has been built. An x-ray detector with directly deposited columnar CsI has been used to minimize signal spill-over into neighboring pixels. Phase contrast images obtained with the system have demonstrated its effectiveness for imaging low-absorption materials.

07 ISOTOPE AND RADIATION SOURCES↗