How to Engage Employees through Technology - The impact of Computer-Based Procedures
This is a presentation describing the LWRS Computer-Based Procedure research conducted at INL 2012-2016.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
This is a presentation describing the LWRS Computer-Based Procedure research conducted at INL 2012-2016.
Quantification of LC-MS peak intensities assigned during peptide identification in a typical comparative proteomics experiment will deviate from run-to-run of the instrument due to both technical and biological variation. Thus, normalization of peak intensities across a LC-MS proteomics dataset is a fundamental step in pre-processing. However, the downstream analysis of LC-MS proteomics data can be dramatically affected by the normalization method selected . Current normalization procedures for LC-MS proteomics data are presented in the context of normalization values derived from subsets of the full collection of identified peptides. The distribution of these normalization values is unknown a priori. If they are not independent from the biological factors associated with the experiment the normalization process can introduce bias into the data, which will affect downstream statistical biomarker discovery. We present a novel approach to evaluate normalization strategies, where a normalization strategy includes the peptide selection component associated with the derivation of normalization values. Our approach evaluates the effect of normalization on the between-group variance structure in order to identify candidate normalization strategies that improve the structure of the data without introducing bias into the normalized peak intensities.
Abstract Heat pumping through thermoelectric devices has many advantages over traditional cooling. However, their current efficiency is a limiting factor in their implementation. In this paper, we approach the non-convex topology optimization of thermoelectrical elements for cooling applications through the method of moving asymptotes (MMA) to improve their cooling capabilities per watt usage. The optimization problem is defined for a given power budget, aiming for the minimum temperature with a known heat pumping need. The introduction of power as a constraint justifies the introduction of the voltage gradient across the thermocouple as a design variable to maintain the thermoelectrical device in its optimum power-to-heat extraction ratio. To better understand the convergence of this non-convex problem, we present a two-variable analytical thermoelectric optimization model. This example provides information on how to select the penalty parameters used to scale the three material coefficients involved in the problem to obtain lower objective values and better convergence using MMA. The analytical model shows the non-convexity of the problem and provides the recommendation to use penalization coefficients of the form $$p_k=p_{\sigma }>p_{\alpha }=1$$ p k = p σ > p α = 1 for the thermal conductivity, electrical conductivity, and Seebeck coefficients. We tested these penalization coefficients through optimizations of a model based on the 1MC10-031 commercial thermoelectric-cooler (TEC) using the finite element method (FEM). These penalization coefficients provided local minima without the need for volume constraints. With this procedure, we found designs that provided temperatures close to 10 degrees lower using 60% less semiconductor material volume compared to the initial design.
A large aneurysm of the left renal artery was found incidentally during abdominal ultrasound in a 39-year-old woman with no medical or family history of cardiovascular disease. Vascular pathology with a dysplastic appearance was confirmed by magnetic resonance angiography and the patient was offered transcatheter embolization. Since the position and size of the neck of the aneurysm could not be determined at angiography, detachable platinum coils were used for occlusion. The procedure was performed without complications. During a 4-year follow-up no alterations of renal function, recanalization of the aneurysm, or perfusion defects in the rest of the left renal circulation were noted.
The purpose of this study was to evaluate the usefulness of a tool that we developed to simulate performance of visceral angiography to train beginners in the field of splanchnic angiography. Seven residents and two fellows who were rotating within the Division of Interventional Radiology at our institution between June and August 2008 participated in the evaluation of this tool. They had no experience in performing visceral angiography as an operator. Time for selection of arterial branches arising from the celiac axis on the model was measured before and after training. After such training, the participants performed actual visceral angiography as an operator with instructors beside them. Success of the trainees in selecting visceral arterial branches was evaluated in these real-life cases. In the first test using the model, seven of nine trainees (77.8%) succeeded in selecting all required arteries, while the remaining two failed to select all required arteries. After training using the model, all trainees succeeded in selecting all required arteries just before the actual angiographic study. In the actual angiography, the catheter was successfully inserted from the femoral artery and advanced to the superior mesenteric, celiac, splenic, common hepatic, gastroduodenal, and right and left hepatic arteries by all trainees with only two exceptions. In conclusion, this tool is helpful for training beginners in visceral angiographic procedures.
Percutaneous image-guided thermal ablation of tumor is widely used, and thermal injury to collateral structures is a known complication of this technique. To avoid thermal damage to surrounding structures, several protection techniques have been reported. We report the use of a simple and effective protective technique combining carbon dioxide dissection and thermocouple: CO{sub 2} displaces the nontarget structures, and its low thermal conductivity provides excellent insulation; insertion of a thermocouple in contact with vulnerable structures achieves continuous thermal monitoring. We performed percutaneous thermal ablation of 37 tumors in 35 patients (4 laser, 10 radiofrequency, and 23 cryoablations) with protection of adjacent vulnerable structures by using CO{sub 2} dissection combined with continuous thermal monitoring with thermocouple. Tumor locations were various (19 intra-abdominal tumors including 4 livers and 9 kidneys, 18 musculoskeletal tumors including 11 spinal tumors). CO{sub 2} volume ranged from 10 ml (epidural space) to 1500 ml (abdominal). Repeated insufflations were performed if necessary, depending on the information given by the thermocouple and imaging control. Dissection with optimal thermal protection was achieved in all cases except two patients where adherences (one postoperative, one arachnoiditis) blocked proper gaseous distribution. No complication referred to this technique was noted. This safe, cost-effective, and simple method increases the safety and the success rate of percutaneous thermal ablation procedures. It also offers the potential to increase the number of tumors that can be treated via a percutaneous approach.
Complications of embolization and chemoembolization remain a problem even with the development of low-profile catheter material and the introduction of new embolization agents. In recent years many new embolization materials have become available for clinical use, so the possibilities and limitations of these new materials must be understood to allow safe and effective embolization. Although up to now some scientific work has been published reporting the basic risk of embolization procedures, the underlying pathomechanism remains the object of speculation. Besides complications like drug toxicity, allergic reactions, and bleeding of the puncture site, the characteristics of embolization materials must be known to understand the potential complications of nontarget embolization and reflux of embolization material. This article gives an overview of established and new embolization materials, their potential risks, and the underlying pathophysiology.
We present a safe and quick technique for crossover embolization procedures of the internal iliac artery with high-profile guiding catheter systems, after a pull-through maneuver with establishment of a crossover catheter-snare system. The attached snare is used to stabilize and direct the guiding catheter.
Personalized therapies play an increasingly critical role in cancer care: Image guidance with multimodality image fusion facilitates the targeting of specific tissue for tissue characterization and plays a role in drug discovery and optimization of tailored therapies. Positron-emission tomography (PET), magnetic resonance imaging (MRI), and contrast-enhanced computed tomography (CT) may offer additional information not otherwise available to the operator during minimally invasive image-guided procedures, such as biopsy and ablation. With use of multimodality image fusion for image-guided interventions, navigation with advanced modalities does not require the physical presence of the PET, MRI, or CT imaging system. Several commercially available methods of image-fusion and device navigation are reviewed along with an explanation of common tracking hardware and software. An overview of current clinical applications for multimodality navigation is provided.
PurposeThis prospective pilot study was undertaken to evaluate the feasibility and effectiveness of using a radiation absorbing shield to reduce operator dose from scatter during lower limb endovascular procedures.Materials and MethodsA commercially available bismuth shield system (RADPAD) was used. Sixty consecutive patients undergoing lower limb angioplasty were included. Thirty procedures were performed without the RADPAD (control group) and thirty with the RADPAD (study group). Two separate methods were used to measure dose to a single operator. Thermoluminescent dosimeter (TLD) badges were used to measure hand, eye, and unshielded body dose. A direct dosimeter with digital readout was also used to measure eye and unshielded body dose. To allow for variation between control and study groups, dose per unit time was calculated.ResultsTLD results demonstrated a significant reduction in median body dose per unit time for the study group compared with controls (p = 0.001), corresponding to a mean dose reduction rate of 65 %. Median eye and hand dose per unit time were also reduced in the study group compared with control group, however, this was not statistically significant (p = 0.081 for eye, p = 0.628 for hand). Direct dosimeter readings also showed statistically significant reduction in median unshielded body dose rate for the study group compared with controls (p = 0.037). Eye dose rate was reduced for the study group but this was not statistically significant (p = 0.142).ConclusionInitial results are encouraging. Use of the shield resulted in a statistically significant reduction in unshielded dose to the operator’s body. Measured dose to the eye and hand of operator were also reduced but did not reach statistical significance in this pilot study.
PurposeTo compare image quality and radiation exposure between a new angiographic imaging system and the preceding generation system during uterine artery embolization (UAE).Materials and MethodsIn this retrospective, IRB-approved two-arm study, 54 patients with symptomatic uterine fibroids were treated with UAE on two different angiographic imaging systems. The new system includes optimized acquisition parameters and real-time image processing algorithms. Air kerma (AK), dose area product (DAP) and acquisition time for digital fluoroscopy (DF) and digital subtraction angiography (DSA) were recorded. Body mass index was noted as well. DF image quality was assessed objectively by image noise measurements. DSA image quality was rated by two blinded, independent readers on a four-rank scale. Statistical differences were assessed with unpaired t tests and Wilcoxon rank-sum tests.ResultsThere was no significant difference between the patients treated on the new (n = 36) and the old system (n = 18) regarding age (p = 0.10), BMI (p = 0.18), DF time (p = 0.35) and DSA time (p = 0.17). The new system significantly reduced the cumulative AK and DAP by 64 and 72%, respectively (median 0.58 Gy and 145.9 Gy*cm{sup 2} vs. 1.62 Gy and 526.8 Gy*cm{sup 2}, p < 0.01 for both). Specifically, DAP for DF and DSA decreased by 59% (75.3 vs. 181.9 Gy*cm{sup 2}, p < 0.01) and 78% (67.6 vs. 312.2 Gy*cm{sup 2}, p < 0.01), respectively. The new system achieved a significant decrease in DF image noise (p < 0.01) and a significantly better DSA image quality (p < 0.01).ConclusionsThe new angiographic imaging system significantly improved image quality and reduced radiation exposure during UAE procedures.
PurposeTo evaluate a commercially available robotic assistance device for computed tomography-guided diagnostic and therapeutic interventions, compared to regular, manually performed CT scan-guided interventions in terms of precision, exposure to radiation to the patient and intervention time.Materials and MethodsOver a period of 6 months, 55 consecutive patients were recruited and treated using robotic assistance and compared to a control group of 101 patients previously treated with a regular CT scan-guided, manual approach. Evaluated parameters were precision (deviation from planned target and number of needle replacements), radiation exposure to the patient and intervention time. Evaluations were performed with regard to complexity (in-plane vs out-of-plane interventions) and type of anesthesia (general vs local).ResultsParameters related to precision were in general significantly better in the robotic assistance group (p < 0.01) with a mean deviation of 1.2 mm (± 1.6 mm) compared to 2.6 mm (± 1.1 mm) in the comparison group. Compared to manual procedure, the mean intervention time was reduced by 15 min (± 5.4 min) on average for an out-of-plane needle placement in the robotic group. There was no increase of exposure to radiation to the patient while radiation exposure for the physician was reduced to zero when the navigation system was used.ConclusionCompared to manual placement, the use of a robotic assistance device in out-of-plane CT-guided interventions under general anesthesia allows for probe placement with high precision. Intervention time is reduced with no increase of exposure to radiation to the patient.
Purpose: To report technical success and clinical outcomes of transfemoral venous access for upper extremity dialysis interventions. Materials and Methods: A total of 15 patients underwent a transfemoral venous approach for fistulography (n = 4; 27%) or thrombectomy (n = 11; 73%) over a 14-month period. Access characteristics, sheath size, thrombectomy method, angioplasty site, fluoroscopy time, radiation dose, technical and clinical success, complications, and post-intervention primary and secondary patency rates were recorded. Results: Access type included arteriovenous fistulas (n = 10; 67%) and grafts (n = 5; 33%). The most common configuration was brachio-brachial (n = 6; 38%). Mean age of access was 37 months. Mean prior interventions were 4. Right CFV access was used in all patients using 6–8-French (most common: 7-French [n = 10; 67%]) sheaths. Most thrombectomies (n = 11; 73%) required both pharmacologic and mechanical maceration (n = 9; 82%). All accesses required angioplasty to treat underlying stenosis at the outflow vein (n = 12; 80%) or arteriovenous anastomosis (n = 9; 90%). Mean fluoroscopy time was 26.43 min. Air kerma and dose area product were 178.06 ± 225.77 mGy and 57,768.83 ± 87,553.29 μGym{sup 2}, respectively. Procedural and clinical success rates were 93% and 80%, respectively. Technical failure was due to persistent stenosis in one patient. Clinical failure was due to unsuccessful dialysis immediately following intervention in three patients. Mean post-intervention primary patency and secondary patency durations were 2.8 and 4.8 months, respectively. Primary patency rates at 1 and 3 months were 50% and 35%, respectively. Secondary patency rates at 1 and 3 months were 58% and 30%, respectively. Conclusion: A transfemoral venous approach for intervention of upper extremity dialysis accesses may be a valuable adjunct to traditional approaches.
A procedure is proposed for enhancement of the hydrologic safety of entities in the tail races of dams.
An appropriate filler is a key component required to achieve an useful composite with expected properties. Not only sophisticated types of filler, like graphene are popular, but also more common ones, like silica flour or fly ash because of their low costs. Besides production costs, adequate size and possibility of functionalization of particles surface to create stable bonds with a matrix are essential in filler selection. To create an useful filler for epoxy resin based composites with use of a waste material, namely fly ash, two-step procedure was proposed. In the first part, raw material was sieved and five different ranges of the filler size were obtained. After mechanical tests with fracture toughness, tensile strength and Young Modulus, as well thermal conductivity, the best size of the fly ash was chosen for further modification. During the second step, filler was modified with coupling agent [3-(2-aminoethylamino)propyl]trimethoxysilane in order to enhance the coupling between particular components of composite. Presence of the silane layer was confirmed with infrared spectroscopy and scanning electron microscopy measurements, whilst prepared epoxy composite filled with silanized fly ash was examined similarly as previous composites. Obtained results have proved the significant influence of size of a filler and bonding to the matrix on mechanical and thermal properties of fly ash-epoxy resin composite. Proposed simple method of fly ash modification is an environmentally friendly way for utilization of the fly ash. Moreover, it creates an alternative material applicable in electrical devices as functional composite.
The methods of automation of the procedure for crystal structure model refinement from experimental diffraction data, implemented in the ASTRA program package, are described. Such tools as statistical tests, parameter scanning, and data scanning reduce the time necessary for structural investigation. At strong correlations between parameters, especially when the data set is limited, parameter scanning has an advantage over the full-matrix refinement.
Terpenes are the primary determinants of cannabis flower aroma, and ongoing research tests their potential for impacting the overall experience. Frustratingly, despite the importance of terpenes in cannabis physiology and commercial uses, literature reports vary widely regarding the major constituents of volatile blends and the concentrations of individual terpenes. Here, in this article, we provide detailed descriptions of complementary approaches that will allow researchers to determine the identity and quantity of cannabis terpenes unequivocally and reliably. These standard operating procedures will guide decisions about which method to employ to address specific analytical goals. We are including two application examples to illustrate the utility of different approaches for tackling the analysis of terpenes in cannabis flower samples.
We describe a general procedure to calibrate the detection of a nano/micro-mechanical resonator’s displacement as it undergoes thermal Brownian motion. A brief introduction to the equations of motion for such a resonator is presented, followed by a detailed derivation of the corresponding power spectral density (PSD) function, which is identical in all situations aside from a system-dependent effective mass value. The effective masses for a number of different resonator geometries are determined using both finite element method (FEM) modeling and analytical calculations. -- Highlights: •Model micro- and nanomechanical resonators displaced by their own thermal motion. •Review the theoretical framework for describing thermomechanical systems. •Present a recipe for measurement calibration on devices of arbitrary shape. •Point out and correct inconsistencies in the existing literature. •Provide an authoritative guide and reference for practitioners in this area.