Search NASA⌕ Search

SEARCH · Search NASA

Results for “Quality Attributes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Technology to Establish a Factory for High QE Alkali Antimonide Photocathodes

Intense electron beams are key to a large number of scientific endeavors, including electron cooling of hadron beams, electron-positron colliders, secondary-particle beams such as photons and positrons, sub-picosecond ultrafast electron diffraction (UED), and new high gradient accelerators that use electron-driven plasmas. The last decade has seen a considerable interest in pursuit and realization of novel light sources such as Free Electron Lasers [1] and Energy Recovery Linacs [2] that promise to deliver unprecedented quality x-ray beams. Many applications for high-intensity electron beams have arisen in recent years in high-energy physics, nuclear physics and energy sciences, such as recent designs for an electron-hadron collider at CERN (LHeC) [3], and beam coolers for hadron beams at LHC and eRHIC [4,5]. Photoinjectors are used at the majority of high-brightness electron linacs today, due to their efficiency, timing structure flexibility and ability to produce high power, high brightness beams. The performance of light source machines is strongly related to the brightness of the electron beam used for generating the x-rays. The brightness of the electron beam itself is mainly limited by the physical processes by which electrons are generated. For laser based photoemission sources this limit is ultimately related to the properties of photocathodes [6]. Most facilities are required to expend significant manpower and money to achieve a workable, albeit often non-ideal, compromise photocathode solution. If entirely fabricated in-house, the photocathode growth process itself is laborious and not always reproducible: it involves the human element while requiring close adherence to recipes and extremely strict control of deposition parameters. Lack of growth reliability and as a consequence, slow adoption of viable photoemitter types, can be partly attributed to the absence of any centralized facility or commercial entity to routinely provide high peak current capable, low emittance, visible-light sensitive photocathodes to the myriad of source systems in use and under development. Successful adoption of photocathodes requires strict adherence to proper fabrication, operation, and maintenance methodologies, necessitating specialized knowledge and skills. Key issues include the choice of photoemitter material, development of a more streamlined growth process to minimize human operator uncertainties, accommodation of varying photoemitter substrate materials and geometries, efficient transport and insertion mechanisms preserving the photo-yield, and properly conveyed photoemitter operational and maintenance methodologies. AES, in collaboration with Cornell University in a Phase I STTR, developed an on-demand industrialized growth and centralized delivery system for high-brightness photocathodes focused upon the alkali antimonide photoemitters. To the end user, future photoemitter sourcing will become as simple as other readily available consumables, rather than a research project requiring large investments in time and personnel.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydrogen Dynamics in Supercritical Water Probed by Neutron Scattering and Computer Simulations

In this work, an investigation of supercritical water is presented combining inelastic and deep inelastic neutron scattering experiments and molecular dynamics simulations based on a machine-learned potential of ab initio quality. The local hydrogen dynamics is investigated at 250 bar and in the temperature range of 553–823 K, covering the evolution from subcritical liquid to supercritical gas-like water. The evolution of libration, bending, and stretching motions in the vibrational density of states is studied, analyzing the spectral features by a mode decomposition. Moreover, the hydrogen nuclear momentum distribution is measured, and its anisotropy is probed experimentally. It is shown that hydrogen bonds survive up to the higher temperatures investigated, and we discuss our results in the framework of the coupling between intramolecular modes and intermolecular librations. Results show that the local potential affecting hydrogen becomes less anisotropic within the molecular plane in the supercritical phase, and we attribute this result to the presence of more distorted hydrogen bonds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of laser power on roughness and porosity in laser powder bed fusion of stainless steel 316L alloys measured by X-ray tomography

The quality of metal objects fabricated via laser powder bed fusion are highly affected by process parameters, and their influence on final products is yet to be fully explored. In this work, pyrometry signals of the melt pool were collected from a set of stainless-steel samples during manufacturing and the effect of laser power on porosity and roughness of final printed parts was analyzed. Results show that the melt pool pyrometry signal of contours increases with higher laser power, whereas it is lower and decreases for the infilled part. Post-built X-ray computed tomography imaging reveals that porosity decreases while sample roughness increases upon increasing laser power. The decrease in porosity with increasing laser power is attributed to the larger size of the contour welds that were printed first, leading to an increase in dimension of the final products.

36 MATERIALS SCIENCE↗

Intelligent Entity Behavior Within Synthetic Environments

This paper describes some elements in the development of realistic performance and behavior in the synthetic entities (players) which support Modeling and Simulation (M&S) applications, particularly military training. Modern human-in-the-loop (virtual) training systems incorporate sophisticated synthetic environments, which provide: 1. The operational environment, including, for example, terrain databases; 2. Physical entity parameters which define performance in engineered systems, such as aircraft aerodynamics; 3. Platform/system characteristics such as acoustic, IR and radar signatures; 4. Behavioral entity parameters which define interactive performance, including knowledge/reasoning about terrain, tactics; and, 5. Doctrine, which combines knowledge and tactics into behavior rule sets. The resolution and fidelity of these model/database elements can vary substantially, but as synthetic environments are designed to be compose able, attributes may easily be added (e.g., adding a new radar to an aircraft) or enhanced (e.g. Amending or replacing missile seeker head/ Electronic Counter Measures (ECM) models to improve the realism of their interaction). To a human in the loop with synthetic entities, their observed veridicality is assessed via engagement responses (e.g. effect of countermeasures upon a closing missile), as seen on systems displays, and visual (image) behavior. The realism of visual models in a simulation (level of detail as well as motion fidelity) remains a challenge in realistic articulation of elements such as vehicle antennae and turrets, or, with human figures; posture, joint articulation, response to uneven ground. Currently the adequacy of visual representation is more dependant upon the quality and resolution of the physical models driving those entities than graphics processing power per Se. Synthetic entities in M&S applications traditionally have represented engineered systems (e.g. aircraft) with human-in-the-loop performance characteristics (e.g. visual acuity) included in the system behavioral specification. As well, performance affecting human parameters such as experience level, fatigue and stress are coming into wider use (via AI approaches) to incorporate more uncertainty as to response type as well as performance (e.g. Where an opposing entity might go and what it might do, as well as how well it might perform).

Kruk, R. V.↗

Epitaxial growth of high quality SrFeO 3 films on (001) oriented (LaAlO 3 ) 0.3 (Sr 2 TaAlO 6 ) 0.7

Growth of strontium ferrite SrFeO 3 films with stoichiometry of (1:1:3) is challenging as the unstable Fe 4+ oxidation state favors the formation of O vacancies. Here, we report layer by layer growth of SrFeO 3 on (001) oriented (LaAlO 3 ) 0.3 (Sr 2 TaAlO 6 ) 0.7 using ozone assisted molecular beam epitaxy. Upon cooling from room temperature, the film’s resistivity decreased from 750 μΩ cm to 150 μΩ cm, as low as the best single crystals, with two identifiable transition points near 110 K and 60 K in resistivity measurements, being hysteretic between cooling and warming through the 60 K transition. During various annealing steps, the low temperature resistivity changes by orders of magnitude, accompanied by an increase in the c-axis lattice parameter. The hysteresis near 60 K persists for a wide range of annealing conditions. We have identified conditions under which changes due to annealing can be reversed. Here, we attribute changes in resistivity and out of plane lattice parameter to the reversible movement of oxygen ions in the lattice. SrFeO 3 may be a promising material for resistive memory applications based upon the control of oxygen vacancies.

36 MATERIALS SCIENCE↗

Zero added oxygen for high quality sputtered ITO: A data science investigation of reduced Sn-content and added Zr

The authors demonstrate mobilities of >45 cm{sup 2}/V s for sputtered tin-doped indium oxide (ITO) films at zero added oxygen. All films were deposited with 5 wt. % SnO{sub 2}, instead of the more conventional 8–10 wt. %, and had varying ZrO{sub 2} content from 0 to 3 wt. %, with a subsequent reduction in In{sub 2}O{sub 3} content. These films were deposited by radio-frequency magnetron sputtering from nominally stoichiometric targets with varying oxygen partial pressure in the sputter ambient. Anomalous behavior was discovered for films with no Zr-added, where a bimodality of high and low mobilities was discovered for nominally similar growth conditions. However, all films showed the lowest resistivity and highest mobilities when the oxygen partial pressure in the sputter ambient was zero. This result is contrasted with several other reports of ITO transport performance having a maximum for small but nonzero oxygen partial pressure. This result is attributed to the reduced concentration of SnO{sub 2}. The addition of ZrO{sub 2} yielded the highest mobilities at >55 cm{sup 2}/V s and the films showed a modest increase in optical transmission with increasing Zr-content.

36 MATERIALS SCIENCE↗

Solvent Quality Effects on Scaling Behavior of Poly(methyl methacrylate) Brushes in the Moderate- and High-Density Regimes

Herein, we give a detailed experimental analysis for scaling law behavior in the “moderately dense” and “high-density” brush regimes for poly(methyl methacrylate) brushes swollen in a range of solvent conditions. This expansive experimental analysis aims to validate decades of mean field theory predictions on power law scaling behavior of grafted polymer chains. Brushes with grafting densities (σ) ranging from 0.1 to 0.8 nm –2 are prepared by atom-transfer radical polymerization. The swollen thickness (h) is characterized using liquid cell ellipsometry, and the solvent quality is varied using mixtures of acetone and methanol. In a good solvent, the exponential scaling behavior (h ∝ σ n ) has the typical n = 1/3 dependency for grafting densities of σ ≤ 0.4 nm –2 . For grafting densities of >0.4 nm –2 , n increases, indicating the transition from the moderately dense to the high-density brush regime. Furthermore, in a poor solvent, the scaling behavior is independent of σ and scales as h ∝ σ0.80, approaching the theoretical expectations of h ∝ σ 1 . An abrupt transition between these scaling law behaviors occurs at the Θ-solvent condition of ~45% (v/v) methanol in acetone. While our experimental results parallel trends predicted by mean field theory, differences are observed and appear to be attributed to self-solvation of the polymer, polydispersity in the molecular weight, and chain termination.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Source scaling comparison and validation in Central Italy: data intensive direct S waves versus the sparse data coda envelope methodology

SUMMARY Robustness of source parameter estimates is a fundamental issue in understanding the relationships between small and large events; however, it is difficult to assess how much of the variability of the source parameters can be attributed to the physical source characteristics or to the uncertainties of the methods and data used to estimate the values. In this study, we apply the coda method by Mayeda et al. using the coda calibration tool (CCT), a freely available Java-based code (https://github.com/LLNL/coda-calibration-tool) to obtain a regional calibration for Central Italy for estimating stable source parameters. We demonstrate the power of the coda technique in this region and show that it provides the same robustness in source parameter estimation as a data-driven methodology [generalized inversion technique (GIT)], but with much fewer calibration events and stations. The Central Italy region is ideal for both GIT and coda approaches as it is characterized by high-quality data, including recent well-recorded seismic sequences such as L'Aquila (2009) and Amatrice–Norcia–Visso (2016–2017). This allows us to apply data-driven methods such as GIT and coda-based methods that require few, but high-quality data. The data set for GIT analysis includes ∼5000 earthquakes and more than 600 stations, while for coda analysis we used a small subset of 39 events spanning 3.5 < Mw < 6.33 and 14 well-distributed broad-band stations. For the common calibration events, as well as an additional 247 events (∼1.7 < Mw < ∼5.0) not used in either calibration, we find excellent agreement between GIT-derived and CCT-derived source spectra. This confirms the ability of the coda approach to obtain stable source parameters even with few calibration events and stations. Even reducing the coda calibration data set by 75 per cent, we found no appreciable degradation in performance. This validation of the coda calibration approach over a broad range of event size demonstrates that this procedure, once extended to other regions, represents a powerful tool for future routine applications to homogeneously evaluate robust source parameters on a national scale. Furthermore, the coda calibration procedure can homogenize the Mw estimates for small and large events without the necessity of introducing any conversion scale between narrow-band measures such as local magnitude (ML) and Mw, which has been shown to introduce significant bias.

Morasca, Paola (ORCID:0000000265254867)↗

Characterizing performance of ultra-sensitive accelerometers

An overview is given of methodology and test results pertaining to the characterization of ultra sensitive accelerometers. Two issues are of primary concern. The terminology ultra sensitive accelerometer is used to imply instruments whose noise floors and resolution are at the state of the art. Hence, the typical approach of verifying an instrument's performance by measuring it with a yet higher quality instrument (or standard) is not practical. Secondly, it is difficult to find or create an environment with sufficiently low background acceleration. The typical laboratory acceleration levels will be at several orders of magnitude above the noise floor of the most sensitive accelerometers. Furthermore, this background must be treated as unknown since the best instrument available is the one to be tested. A test methodology was developed in which two or more like instruments are subjected to the same but unknown background acceleration. Appropriately selected spectral analysis techniques were used to separate the sensors' output spectra into coherent components and incoherent components. The coherent part corresponds to the background acceleration being measured by the sensors being tested. The incoherent part is attributed to sensor noise and data acquisition and processing noise. The method works well for estimating noise floors that are 40 to 50 dB below the motion applied to the test accelerometers. The accelerometers being tested are intended for use as feedback sensors in a system to actively stabilize an inertial guidance component test platform.

Sebesta, Henry↗

AVOID BECOMING A VICTIM OF COUNTERFEIT ITEMS

In today's globalized economy, we cannot live without imported products. Most people do not realize how thin the safety net of regulation and inspection really is. Less than three percent of imported products receive any form of government inspection prior to sale. Avoid flea markets, street vendors and deep discount stores. The sellers of counterfeit wares know where to market their products. They look for individuals who are hungry for a brand name item but do not want to pay a brand name price for it. The internet provides anonymity to the sellers of counterfeit products. Unlike Europe, U.S. law does not hold internet-marketing organizations, responsible for the quality of the products sold on their websites. These organizations will remove an individual vendor when a sufficient number of complaints are lodged, but they will not take responsibility for the counterfeit products you may have purchased. EBay has a number of counterfeit product guides to help you avoid being a victim of the sellers of these products. Ten percent of all medications taken worldwide are counterfeit. If you do buy medications on-line, be sure that the National Association of Boards of Pharmacy Verified Internet Pharmacy Practice Sites (VIPPS) recommends the pharmacy you choose to use. Inspect all medication purchases and report any change in color, shape, imprinting or odor to your pharmacist. If you take generic medications these attributes may change from one manufacturer to another. Your pharmacist should inform you of any changes when you refill your prescription. If they do not, get clarification prior to taking the medication. Please note that the Federal Drug Administration (FDA) does not regulate supplements. The FDA only steps in when a specific supplement proves to cause physical harm or contains a regulated ingredient. Due to counterfeiting, Underwriters Laboratories (UL) changed their label design three times since 1996. The new gold label should be attached to the cord or body of most office and home electrical products (please see the picture to the left). Holiday lights may have the UL marking in red or green instead of the universal black. A red UL mark indicates the product is approved for outdoor as well as indoor service. The green UL mark indicates the product is only to be used indoors. A small number of home electrical products may bear an Interteck (ETL) approval. This label is also acceptable. An Interteck label includes black print on a white background bearing the circular ETL logo. Most manufacturers are proud of their products and strive to gain name recognition as well as foster repeat business. This is not true of counterfeiters. The very first thing most counterfeiters try to do is make their products untraceable. Their products may bear the nation of origin but that is all. This is a common practice with metal components such as pipe fittings and flanges. This is also true of hoisting and rigging equipment such as shackles, turnbuckles and chain. Sadly, this has also occurred with the purchase of some safety equipment such as arc-flash retardant coveralls. Learn the national standards associated with products you are purchasing. Clearly specify these requirements on the procurements you make.

99 GENERAL AND MISCELLANEOUS↗

Peptide‐Passivated Lead Halide Perovskite Nanocrystals Based on Synergistic Effect between Amino and Carboxylic Functional Groups

A new strategy has been developed using peptides with amino and carboxylic functional groups as passivating ligands to produce methyl ammonium lead bromide (CH 3 NH 3 PbBr 3 ) perovskite nanocrystals (PNCs) with excellent optical properties. The well‐passivated PNCs can only be obtained when both amino and carboxylic groups are involved, and this is attributed to the protonation reaction between NH 2 and COOH that is essential for successful passivation of the PNCs. To better understand this synergistic effect, peptides with different lengths have been studied and compared. Due to the polar nature of peptides, peptide‐passivated PNCs (denoted as PNCs peptide ) aggregate and precipitate from nonpolar toluene solvent, resulting in a high product yield (≈44%). Furthermore, the size of PNCs peptide can be varied from ≈3.9 to 8.6 nm by adjusting the concentration of the peptide, resulting in tunable optical properties due to the quantum confinement effect. In addition, CsPbBr 3 PNCs are also synthesized with peptides as capping ligands, further demonstrating the generality and versatility of this strategy, which is important for generating high quality PNCs for photonics applications including light‐emitting diodes, optical sensing, and imaging.

Luo, Binbin↗

Towards a framework for the assessment of saltwater intrusion in coastal aquifers

Saltwater intrusion (SWI) represents a threat to coastal aquifers worldwide by rendering groundwater quality not viable for its intended purposes. Therefore, understanding SWI impacts is indispensable for informed decision-making on aquifer management. Despite advances in methods to assess the impact of SWI, it remains challenging to select appropriate methods that are effective, timely, and affordable under the influence of a range of factors including aquifer characteristics, hydro-geochemical dynamics, shoreline geomorphology, biochemical reactions, and data availability among others. This study examines commonly used methods that assess the impact of SWI towards the development of an assessment framework in coastal aquifers underlying densely populated urban areas. The methods were selected using complexity-functionality criteria and then tested at a pilot aquifer by coupling Strengths, Weaknesses, Opportunities and Threats (SWOT) and Multi-Attribute Decision Making (MADM) analyses to evaluate the effectiveness of the methods and identify elements of the framework. The framework proved functional in synthesizing parametric results, assessing the dynamics of SWI and quantifying its potential impact, as well as providing an effective platform for informed impact assessment and planning for sustainable exploitation of coastal aquifers. - Highlights: •Assessing hydrogeochemical indices and geostatistical analysis to evaluate SWI •Coupling SWOT and MADM analysis to evaluate alternative SWI assessment methods •Developing an impact assessment framework for SWI in coastal aquifers •Testing of SWI framework in a heterogeneous aquifer along the Eastern Mediterranean.

54 ENVIRONMENTAL SCIENCES↗

Spectral indices measurements using miniature fission chambers at the MINERVE zero-power reactor at CEA using calibration data obtained at the BR1 reactor at SCK.CEN

Spectral indices are parameters of major importance to characterize a multiplying medium and to evaluate performances of neutronics calculation tools as well as quality of associated nuclear data. Experiments performed in 2004 at the CEA MINERVE facility loaded with the R1-UO{sub 2} lattice [1], using homemade miniature fission chambers and calibration data acquired at the SCK.CEN BR1 facility in 2001 [2], resulted in ambivalent conclusions. On one hand, spectral indices involving only fissile isotopes gave relevant results and consistent discrepancies between calculation and experiment. On the other hand, spectral indices involving both fissile and fertile isotopes showed inconsistent results depending on the type of calibration data used. In particular, the {sup 238}U(n,f)/{sup 235}U(n,f) spectral indices resulted in values far from the calculations in all cases. In 2004, those differences between measurement and calculation were mainly attributed to an imprecise knowledge of the isotopic composition of the deposits loaded in the {sup 238}U chambers. At that time, priorities in the development of programs in MINERVE and other considerations about the manufacturing and calibration of new fission chambers did not allow to further investigate these discrepancies. In 2009, the preparation of a new program at the EOLE facility [1] and changes in the regulatory framework for management of fission chambers motivated the manufacturing of new detectors. At the same time, the re-installation of the R1-UO{sub 2} lattice in MINERVE gave the opportunity to carry out a new spectral indices measurement campaign. Nevertheless, although the isotopic composition of active deposits was better known than previously, the comparison between experimental results and calculations still resulted in inconsistent discrepancies. A sensitivity study indicated afterwards that, among all parameters to be considered for the analysis and the assessment of final uncertainty, calibration data have the greatest impact. In April 2010, a new calibration campaign conducted again at the BR1 facility allowed the CEA to reanalyze the spectral indices measurements performed in 2009. With this new set of calibration data, the experimental values of spectral indices finally matched the calculation results within the uncertainty margins. In addition, the confrontation of data from 2001 and 2010 calibration campaigns, both performed with the same experimental conditions, allowed to shed on the light dead time correction issues in the monitoring of calibration measurements. At the end, this also explained the inconsistencies observed during the 2004 campaign. This paper first, presents the two different analysis methods for getting the experimental value of a spectral index and, lists main parameters that influence the determination of the experimental value. It then details the calibration processes that are set-up at the MINERVE and BR1 facilities, describes the various experiments carried out and finally comments the results obtained. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Collaborative Research: Properties and Dynamics of the Shallow Crust (Final Report)

Ground motions recorded at one location are often extrapolated to nearby regions within a given radius. Here, we explore the appropriateness of spatial extrapolation using data from seven small aperture seismic network deployments in southern California. Six of these deployments are linear arrays of 4-13 stations, and one is a 2D array of 13 stations at Pinyon Flats Observatory. The spatial footprint array diameters are 3 km or less, and each array was operational for a year or more. From our base catalog (M2.5+ earthquakes; 4038 events; September 2010 - June 2023), automated methods remove temporally overprinted waveforms from nearby events (< 5 km) in quick succession (< 5 min) and data with nonviable waveforms. These 200 samples per second data are filtered at 0.5-25 Hz and must have signal-tonoise ratios (SNRs) of 2.5+. Peak ground acceleration (PGA) and peak ground velocity (PGV) are derived individually from the maximum absolute values of each of the 3-component waveforms (vertical, northsouth, and east-west). Five of the seven arrays traverse the San Jacinto fault, and two do not. Ground motion observations are compared with theoretical estimates from Abrahamson et al., 2014. On average, arrays deployed within and across fault zones consistently record ground motions above theoretical expectations, whereas off-fault arrays record ground motions at or slightly below theoretical expectations. We attribute these differences to site conditions because these trends prevail for the full data suites. For each network and each individual channel, the coefficient of variation indicates that the standard deviations are ~30±6% of the mean. Exploring relative ground motion contributions from all three channels (ternary plots), as expected, most data show that vertical ground motions are attenuated compared to horizontal ones. However, this is not always the case for RA array data, where vertical motions can be ~2-3 times larger than horizontal motions for select events near Cahuilla, CA. These anomalously high vertical motions are focal mechanism-related. These results suggest that ternary plots created using only a small amount of data can be used as a data quality metric and a tool to find anomalous features in three-component data.

58 GEOSCIENCES↗

Investigating ion recombination effects in a liquid-filled ionization chamber array used for IMRT QA measurements

Purpose: PTW’s Octavius 1000 SRS array performs IMRT quality assurance (QA) measurements with liquid-filled ionization chambers (LICs) to allow closer detector spacing and higher resolution, compared to air-filled QA devices. However, reduced ion mobility in LICs relative to air leads to increased ion recombination effects and reduced collection efficiencies that are dependent on Linac pulse frequency and pulse dose. These pulse parameters are variable during an IMRT delivery, which affects QA results. In this study, (1) 1000 SRS collection efficiencies were measured as a function of pulse frequency and pulse dose, (2) two methods were developed to correct changes in collection efficiencies during IMRT QA measurements, and the effects of these corrections on QA pass rates were compared. Methods: To obtain collection efficiencies, the OCTAVIUS 1000 SRS was used to measure open fields of varying pulse frequency, pulse dose, and beam energy with results normalized to air-filled chamber measurements. Changes in ratios of 1000 SRS to chamber measured dose were attributed to changing collection efficiencies, which were then correlated to pulse parameters using regression analysis. The usefulness of the derived corrections was then evaluated using 6 MV and 10FFF SBRT RapidArc plans delivered to the OCTAVIUS 4D system using a TrueBeam (Varian Medical Systems) linear accelerator equipped with a high definition multileaf collimator. For the first correction, MATLAB software was developed that calculates pulse frequency and pulse dose for each detector, using measurement and DICOM RT Plan files. Pulse information is converted to collection efficiency, and measurements are corrected by multiplying detector dose by ratios of calibration to measured collection efficiencies. For the second correction the MU/min in the daily 1000 SRS calibration was chosen to match the average MU/min of the volumetric modulated arc therapy plan. Effects of the two corrections on QA results were examined by performing 3D gamma analysis comparing predicted to measured dose, with and without corrections. Results: Collection efficiencies correlated linearly to pulse dose, while correlations with pulse frequency were less defined, generally increasing as pulse frequency decreased. After complex MATLAB corrections, average 3D gamma pass rates improved by [0.07%,0.40%,1.17%] for 6 MV and [0.29%,1.40%,4.57%] for 10FFF using [3%/3 mm,2%/2 mm,1%/1 mm] criteria. Maximum changes in gamma pass rates were [0.43%,1.63%,3.05%] for 6 MV and [1.00%,4.80%,11.2%] for 10FFF using [3%/3 mm,2%/2 mm,1%/1 mm] criteria. On average, pass rates of simple daily calibration corrections were within 1% of complex MATLAB corrections. Conclusions: OCTAVIUS 1000 SRS ion recombination effects have little effect on 6 MV measurements. However, the effect could potentially be clinically significant for higher pulse dose unflattened beams when using tighter gamma tolerances, especially when small aperture sizes are used, as is common for SRS/SBRT. In addition, ion recombination effects are strongly correlated to changing MU/min, therefore MU/min used in daily 1000 SRS calibrations should be matched to the expected average MU/min of the IMRT plan.

60 APPLIED LIFE SCIENCES↗