Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reconstruction algorithms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Snowmass Computational Frontier: Topical Group Report on Experimental Algorithm Parallelization

The substantial increase in data volume and complexity expected from future experiments will require significant investment to prepare experimental algorithms. These algorithms include physics object reconstruction, calibrations, and processing of observational data. In addition, the changing computing architecture landscape, which will be primarily composed of heterogeneous resources, will continue to pose major challenges with regard to algorithmic migration. Portable tools need to be developed that can be shared among the frontiers (e.g., for code execution on different platforms) and opportunities, such as forums or cross-experimental working groups, need to be provided where experiences and lessons learned can be shared between experiments and frontiers. At the same time, individual experiments also need to invest considerable resources to develop algorithms unique to their needs (e.g., for facilities dedicated to the experiment), and ensure that their specific algorithms will be able to efficiently exploit external heterogeneous computing facilities. Common software tools represent a cost-effective solution, providing ready-to-use software solutions as well as a platform for R&D work. These are particularly important for small experiments which typically do not have dedicated resources needed to face the challenges imposed by the evolving computing technologies. Workforce development is a key concern across frontiers and experiments, and additional support is needed to provide career opportunities for researchers working in the field of experimental algorithm development. Finally, cross-discipline collaborations going beyond high-energy physics are a key ingredient to address the challenges ahead and more support for such collaborations needs to be created. This report targets future experiments, observations and experimental algorithm development for the next 10-15 years.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The formation of quantum images and their transformation and super-resolution reading

Images formed by light with suppressed photon fluctuations are interesting objects for studies with the aim of increasing their limiting information capacity and quality. This light in the sub-Poisson state can be prepared in a resonator filled with a medium with Kerr nonlinearity, in which self-phase modulation takes place. Spatially and temporally multimode light beams are studied and the production of spatial frequency spectra of suppressed photon fluctuations is described. The efficient operation regimes of the system are found. A particular schematic solution is described, which allows one to realize the potential possibilities laid in the formation of the squeezed states of light to a maximum degree during self-phase modulation in a resonator for the maximal suppression of amplitude quantum noises upon two-dimensional imaging. The efficiency of using light with suppressed quantum fluctuations for computer image processing is studied. An algorithm is described for interpreting measurements for increasing the resolution with respect to the geometrical resolution. A mathematical model that characterizes the measurement scheme is constructed and the problem of the image reconstruction is solved. The algorithm for the interpretation of images is verified. Conditions are found for the efficient application of sub-Poisson light for super-resolution imaging. It is found that the image should have a low contrast and be maximally transparent.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Liquid Argon Software Toolkit (LArSoft): Goals, Status and Plan

LArSoft is a toolkit that provides a software infrastructure and algorithms for the simulation, reconstruction and analysis of events in Liquid Argon Time Projection Chambers (LArTPCs). It is used by the ArgoNeuT, LArIAT, MicroBooNE, DUNE (including 35ton prototype and ProtoDUNE) and SBND experiments. The LArSoft collaboration provides an environment for the development, use, and sharing of code across experiments. The ultimate goal is to develop fully automatic processes for reconstruction and analysis of LArTPC events. The toolkit is based on the art framework and has a well-defined architecture to interface to other packages, including to GEANT4 and GENIE simulation software and the Pandora software development kit for pattern recognition. It is designed to facilitate and support the evolution of algorithms including their transition to new computing platforms. The development of the toolkit is driven by the scientific stakeholders involved. The core infrastructure includes standard definitions of types and constants, means to input experiment geometries as well as meta and event- data in several formats, and relevant general utilities. Examples of algorithms experiments have contributed to date are: photon-propagation; particle identification; hit finding, track finding and fitting; electromagnetic shower identification and reconstruction. We report on the status of the toolkit and plans for future work.

Pordes, Rush↗

VariableR Reclustering in Multiple Top Quark and W Boson Events

VariableR jet reclustering is an innovative technique that allows for the reconstruction of boosted object over a wide range of kinematic regimes. Such capability enables the efficient identification of events with multiple boosted top quarks which is a typical signature for new physics processes such as the production of the supersymmetric partner of the gluon. In order to evaluate the performance of the algorithm, the VariableR reclustered jets are compared with fixed radius reclustered jets. The flexibility of the algorithm is tested by reconstructing both boosted top quarks and boosted W bosons. The VariableR reclustering method is found to be more efficient than the fixed radius algorithm at identifying top quarks and W bosons in events with four top quarks, therefore enhancing the sensitivity for gluino searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

VariableR reclustering in multiple top quark events - Oral Presentation

VariableR jet reclustering is an innovative technique that allows for the reconstruction of boosted object over a wide range of kinematic regimes. Such capability enables the efficient identification of events with multiple boosted top quarks which is a typical signature for new physics processes such as the production of the supersymmetric partner of the gluon. In order to evaluate the performance of the algorithm, the VariableR reclustered jets are compared with fixed radius reclustered jets. The flexibility of the algorithm is tested by reconstructing both boosted top quarks and boosted W bosons. The VariableR reclustering method is found to be more efficient than the fixed radius algorithm at identifying top quarks and W bosons in events with four top quarks, therefore enhancing the sensitivity for gluino searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

X-ray microtomographic scanners

The article studies the operating procedures of an X-ray microtomographic scanner and the module of reconstruction and analysis 3D-image of a test sample in particular. An algorithm for 3D-image reconstruction based on image shadow projections and mathematical methods of the processing are described. Chapter 1 describes the basic principles of X-ray tomography and general procedures of the device developed. Chapters 2 and 3 are devoted to the problem of resources saving by the system during the X-ray tomography procedure, which is achieved by preprocessing of the initial shadow projections. Preprocessing includes background noise removing from the images, which reduces the amount of shadow projections in general and increases the efficiency of the group shadow projections compression. In conclusion, the main applications of X-ray tomography are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Algorithms for Forward and Inverse Problem Solutions in Phase Contrast Tomography

PhaseTorch is a python package that implements algorithms for forward and inverse problem solutions in X-ray phase contrast tomography (XPCT). XPCT is useful to reconstruct the 3D distribution of the refractive index decrement and absorption index of an imaged object. PhaseTorch implements algorithms for simulation, reconstruction, and analysis of XPCT data. PhaseTorch provides algorithms for simulation of XPCT data of an object with known refractive and absorption indices. It contains algorithms for reconstructing the projections of the absorption index and refractive index decrement.

Sridhar, Venkatesh↗

Design of smart 3D-digital X-ray microtomographic scanners for non-destructive testing of materials and components of electronic devices with a multilayered structure

The article studies the operating procedures of an X-ray microtomographic scanner and the module of reconstruction and analysis 3D-image of a test sample in particular. An algorithm for 3D-image reconstruction based on image shadow projections and mathematical methods of the processing are described. Chapter 1 describes the basic principles of X-ray tomography and general procedures of the device developed. Chapters 2 and 3 are devoted to the problem of resources saving by the system during the X-ray tomography procedure, which is achieved by preprocessing of the initial shadow projections. Preprocessing includes background noise removing from the images, which reduces the amount of shadow projections in general and increases the efficiency of the group shadow projections compression. Chapter 4 covers general procedures of defect search, which is based on vector analysis principles. In conclusion, the main applications of X-ray tomography are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-210: Independent MU Dose Calculation Software for S and S IMRT Using Modified Clarkson Integration Sector

Purpose: The purpose of this work was to develop and validate an open source independent MU dose calculation software for S and S IMRT based in the algorithm proposed by Kung et.al. Methods: Treatment plans were done using Iplan v4.5 BrainLAB TPS and S and S IMRT modality. A 6MV photon beam produced by a Primus linear accelerator equipped with an Optifocus MLC was used. TPS dose calculation algorithms were pencil beam and Monte Carlo. 230 IMRT treatments plans were selected for the study. The software was written under MALTLAB environment. Treatment plans were imported by the software using RTP format. Field fluences were reconstructed adding all segments.The algorithm implemented in the software calculates the dose at a reference point as the sum of primary and scatter dose. The primary dose is obtained by masking the fluence map with a circle of radius 1cm. The scatter dose is obtained through a shaped ring mask around the previous circle with a thickness of 0.5cm; the rings are increased one after another with constant thickness until cover the entire map of influence. The dosimetric parameters Sc, Sp and TPR vary depending on radio, the transmission effect of the MLC, inverse square law and dose profile are used for the calculation. Results: The average difference between measured and independent calculated dose was 0.4% ± 2.2% [−6.8%, 6.4%]. For 91% of the studied plans the difference was less than 3%. The difference between the measured and TPS dose with pencilbeam algorithm was 2.6% ± 1.41% [−2.0%, 5.6%] and Monte Carlo algorithm was 0.4% ± 1.5% [−4.9%, 3.7%]. The differences obtained are comparable to that obtained with the ionization chamber and TPS. Conclusion: The developed software is suitable for use in S and S IMRT dose calculation. This application is open and can be downloading under request.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-211: Induced Release of Nanocarrier Encapsulated Chemotherapeutic Drugs Using Proton Radiotherapy Beams

Purpose: The purpose of this work was to develop and validate an open source independent MU dose calculation software for S and S IMRT based in the algorithm proposed by Kung et.al. Methods: Treatment plans were done using Iplan v4.5 BrainLAB TPS and S and S IMRT modality. A 6MV photon beam produced by a Primus linear accelerator equipped with an Optifocus MLC was used. TPS dose calculation algorithms were pencil beam and Monte Carlo. 230 IMRT treatments plans were selected for the study. The software was written under MALTLAB environment. Treatment plans were imported by the software using RTP format. Field fluences were reconstructed adding all segments.The algorithm implemented in the software calculates the dose at a reference point as the sum of primary and scatter dose. The primary dose is obtained by masking the fluence map with a circle of radius 1cm. The scatter dose is obtained through a shaped ring mask around the previous circle with a thickness of 0.5cm; the rings are increased one after another with constant thickness until cover the entire map of influence. The dosimetric parameters Sc, Sp and TPR vary depending on radio, the transmission effect of the MLC, inverse square law and dose profile are used for the calculation. Results: The average difference between measured and independent calculated dose was 0.4% ± 2.2% [−6.8%, 6.4%]. For 91% of the studied plans the difference was less than 3%. The difference between the measured and TPS dose with pencilbeam algorithm was 2.6% ± 1.41% [−2.0%, 5.6%] and Monte Carlo algorithm was 0.4% ± 1.5% [−4.9%, 3.7%]. The differences obtained are comparable to that obtained with the ionization chamber and TPS. Conclusion: The developed software is suitable for use in S and S IMRT dose calculation. This application is open and can be downloading under request.

60 APPLIED LIFE SCIENCES↗

Electromagnetic shower reconstruction in the ICARUS liquid argon time projection chamber detector

The ICARUS-T600 liquid argon time projection chamber (LArTPC) detector is taking data at shallow depth as the far detector of the Short Baseline Neutrino (SBN) program at Fermilab, to search for a possible sterile neutrino signal at $\Delta m^{2} \approx 1~\text{eV}^{2}$ with the Booster (BNB) and Main Injector (NuMI) neutrino beams at $\GeV{\sim 0.8}$ and $\GeV{\sim 2}$ average energies respectively. The LArTPC technology, developed by the ICARUS collaboration and now a standard in neutrino physics, offers impressive charged-particle imaging capabilities with $\sim1 \ \text{mm}$ spatial resolution, enabling efficient discrimination between track-like signatures (e.g., from muons, pions, and protons) and electromagnetic showers (from electrons and photons). Moreover, electron and photon signatures can be distinguished both with the calorimetric measurement of local energy depositions at the shower start and with the cm-scale conversion gap signature of photons. This contribution discusses event reconstruction at ICARUS focusing on Pandora, a multi-algorithm pattern recognition software widely used in LArTPC experiments. Over a hundred Pandora algorithms and tools are used to reconstruct cosmic rays and neutrino interactions in the ICARUS detector. Recent developments have focused on the reconstruction of electromagnetic shower signatures, crucial to ensure a robust and efficient reconstruction of charged-current $\nu_e$ interactions, which serve as a key signature of sterile neutrino oscillations at SBN. In this contribution, recent improvements to the reconstruction are discussed, focusing on the discrimination between tracks and electromagnetic showers using neutrino simulations and data.

Triozzi, Riccardo [Padua U.; INFN, Padua] (ORCID:0↗

Non-negative Matrix Factorization for Self-calibration of Photometric Redshift Scatter in Weak-lensing Surveys

Photo- z error is one of the major sources of systematics degrading the accuracy of weak-lensing cosmological inferences. Zhang et al. proposed a self-calibration method combining galaxy–galaxy correlations and galaxy–shear correlations between different photo- z bins. Fisher matrix analysis shows that it can determine the rate of photo- z outliers at a level of 0.01%–1% merely using photometric data and do not rely on any prior knowledge. In this paper, we develop a new algorithm to implement this method by solving a constrained nonlinear optimization problem arising in the self-calibration process. Based on the techniques of fixed-point iteration and non-negative matrix factorization, the proposed algorithm can efficiently and robustly reconstruct the scattering probabilities between the true- z and photo- z bins. The algorithm has been tested extensively by applying it to mock data from simulated stage IV weak-lensing projects. We find that the algorithm provides a successful recovery of the scatter rates at the level of 0.01%–1%, and the true mean redshifts of photo- z bins at the level of 0.001, which may satisfy the requirements in future lensing surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

The effect of exit beam phase aberrations on parallel beam coherent x-ray reconstructions

Diffraction artifacts from imperfect x-ray windows near the sample are an important consideration in the design of coherent x-ray diffraction measurements. In this study, we used simulated and experimental diffraction patterns in two and three dimensions to explore the effect of phase imperfections in a beryllium window (such as a void or inclusion) on the convergence behavior of phasing algorithms and on the ultimate reconstruction. A predictive relationship between beam wavelength, sample size, and window position was derived to explain the dependence of reconstruction quality on beryllium defect size. Defects corresponding to this prediction cause the most damage to the sample exit wave and induce signature error oscillations during phasing that can be used as a fingerprint of experimental x-ray window artifacts. The relationship between x-ray window imperfection size and coherent x-ray diffractive imaging reconstruction quality explored in this work can play an important role in designing high-resolution in situ coherent imaging instrumentation and will help interpret the phasing behavior of coherent diffraction measured in these in situ environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron-neutrino selection and reconstruction in the MicroBooNE LArTPC using the Pandora multi-algorithm pattern recognition

MicroBooNE (the Micro Booster Neutrino Experiment) is a liquid argon time-projection chamber experiment designed for short-baseline neutrino physics, currently running at Fermilab. It aims to address the anomalous excess of low-energy events observed by the MiniBooNE experiment. In this note we present a fully automated event selection algorithm to identify charged-current electron neutrino event candidates with no pions and at least one proton in the final state (ν e CC0π-Np). The efficiency of the current selection algorithm is (46.5±0.3) %. We also show some cuts on kinematic and geometric variables which reject background events. These cuts have been validated by analyzing two event samples orthogonal to our signal. Future improvements have been identified which will improve the reconstruction efficiency, especially at low energy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Completeness map evaluation demonstrated with candidate next-generation cardiac CT architectures

Purpose: In this report, the authors introduce the general concept of the completeness map, as a means to evaluate the completeness of data acquired by a given CT system design (architecture and scan mode). They illustrate the utility of completeness map by applying the completeness map concept to a number of candidate CT system designs, as part of a study to advance the state-of-the-art in cardiac CT. Methods: In order to optimally reconstruct a point within a volume of interest (VOI), the Radon transform on all possible planes through that point should be measured. The authors quantified the extent to which this ideal condition is satisfied for the entire image volume. They first determined a Radon completeness number for each point in the VOI, as the percentage of possible planes that is actually measured. A completeness map is then defined as a 3D matrix of the completeness numbers for the entire VOI. The authors proposed algorithms to analyze the projection datasets in Radon space and compute the completeness number for a fixed point and apply these algorithms to various architectures and scan modes that they are evaluating. In this report, the authors consider four selected candidate architectures, operating with different scan modes, for a total of five system design alternatives. Each of these alternatives is evaluated using completeness map. Results: If the detector size and cone angle are large enough to cover the entire cardiac VOI, a single-source circular scan can have {>=}99% completeness over the entire VOI. However, only the central z-slice can be exactly reconstructed, which corresponds to 100% completeness. For a typical single-source architecture, if the detector is limited to an axial dimension of 40 mm, a helical scan needs about five rotations to form an exact reconstruction region covering the cardiac VOI, while a triple-source helical scan only requires two rotations, leading to a 2.5x improvement in temporal resolution. If the source and detector of an inverse-geometry (IGCT) system have the same axial extent, and the spacing of source points in the axial and transaxial directions is sufficiently small, the IGCT can also form an exact reconstruction region for the cardiac VOI. If the VOI can be covered by the x-ray beam in any view, a composite-circling scan can generate an exact reconstruction region covering the VOI. Conclusions: The completeness map evaluation provides useful information for selecting the next-generation cardiac CT system design. The proposed completeness map method provides a practical tool for analyzing complex scanning trajectories, where the theoretical image quality for some complex system designs is impossible to predict, without yet-undeveloped reconstruction algorithms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-dimensional reconstruction of statistically optimal unit cells of polydisperse particulate composites from microtomography

In this paper, we present a systematic approach for characterization and reconstruction of statistically optimal representative unit cells of polydisperse particulate composites. Microtomography is used to gather rich three-dimensional data of a packed glass bead system. First-, second-, and third-order probability functions are used to characterize the morphology of the material, and the parallel augmented simulated annealing algorithm is employed for reconstruction of the statistically equivalent medium. Both the fully resolved probability spectrum and the geometrically exact particle shapes are considered in this study, rendering the optimization problem multidimensional with a highly complex objective function. A ten-phase particulate composite composed of packed glass beads in a cylindrical specimen is investigated, and a unit cell is reconstructed on massively parallel computers. Further, rigorous error analysis of the statistical descriptors (probability functions) is presented and a detailed comparison between statistics of the voxel-derived pack and the representative cell is made.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Distilling particle knowledge for fast reconstruction at high-energy physics experiments

Knowledge distillation is a form of model compression that allows artificial neural networks of different sizes to learn from one another. Its main application is the compactification of large deep neural networks to free up computational resources, in particular on edge devices. In this article, we consider proton-proton collisions at the High-Luminosity Large Hadron Collider (HL-LHC) and demonstrate a successful knowledge transfer from an event-level graph neural network (GNN) to a particle-level small deep neural network (DNN). Our algorithm, DistillNet, is a DNN that is trained to learn about the provenance of particles, as provided by the soft labels that are the GNN outputs, to predict whether or not a particle originates from the primary interaction vertex. The results indicate that for this problem, which is one of the main challenges at the HL-LHC, there is minimal loss during the transfer of knowledge to the small student network, while improving significantly the computational resource needs compared to the teacher. This is demonstrated for the distilled student network on a CPU, as well as for a quantized and pruned student network deployed on a field programmable gate array. Our study proves that knowledge transfer between networks of different complexity can be used for fast artificial intelligence (AI) in high-energy physics that improves the expressiveness of observables over non-AI-based reconstruction algorithms. Such an approach can become essential at the HL-LHC experiments, e.g. to comply with the resource budget of their trigger stages.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Indoor Localization Algorithms for an Ambulatory Human Operated 3D Mobile Mapping System

Indoor localization and mapping is an important problem with many applications such as emergency response, architectural modeling, and historical preservation. In this paper, we develop an automatic, off-line pipeline for metrically accurate, GPS-denied, indoor 3D mobile mapping using a human-mounted backpack system consisting of a variety of sensors. There are three novel contributions in our proposed mapping approach. First, we present an algorithm which automatically detects loop closure constraints from an occupancy grid map. In doing so, we ensure that constraints are detected only in locations that are well conditioned for scan matching. Secondly, we address the problem of scan matching with poor initial condition by presenting an outlier-resistant, genetic scan matching algorithm that accurately matches scans despite a poor initial condition. Third, we present two metrics based on the amount and complexity of overlapping geometry in order to vet the estimated loop closure constraints. By doing so, we automatically prevent erroneous loop closures from degrading the accuracy of the reconstructed trajectory. The proposed algorithms are experimentally verified using both controlled and real-world data. The end-to-end system performance is evaluated using 100 surveyed control points in an office environment and obtains a mean accuracy of 10 cm. Experimental results are also shown on three additional datasets from real world environments including a 1500 meter trajectory in a warehouse sized retail shopping center.

Corso, N↗