Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Uranus Global Reference Atmospheric Model (Uranus-GRAM) 2024: User Guide

Engineers and mission planners designing vehicles that pass through Uranus’ atmosphere require an atmospheric model that calculates the mean values and variations of atmospheric properties. The Uranus Global Reference Atmospheric Model(Uranus-GRAM)is an engineering- oriented model that provides this information based on data from Voyager observations. Uranus- GRAM is designed to offer mission planners the flexibility to select input parameters such as time, latitude, and longitude. Uranus-GRAM outputs atmospheric constituent data and mean values for atmospheric density, temperature, pressure, and zonal wind along a user defined path. Uranus-GRAM also provides dispersions of density and zonal wind. Uranus-GRAM is one option in the GRAM Suite that shares a common software core with the other planetary GRAMs while maintaining Uranus specific models. Additionally, documentation, including this User Guide, a Programmer’s Manual, and trajectory code interfaces has been made available with the software release. This Technical Memorandum summarizes the atmospheric data model in Uranus-GRAM and provides a guide for the user to obtain, set up, and run the code in various configurations. Section 2 describes the input atmospheric data files and how they are used in Uranus-GRAM. Section 3 explains the process to obtain the Uranus-GRAM code, the data files, and how to set up and run the program. Appendices A through E provide additional details regarding the Uranus-GRAM input and output files. Appendix F provides a history of Uranus-GRAM revisions.

atmospheric models↗

Transit Habitat Government-Reference Conceptual Design Reaction Control System Propulsion Concept Design Data Book

The function of Transit Habitat (TH) Reaction Control System (RCS) propulsion is to provide free-flying spacecraft capabilities and to augment Gateway stack control when docked on Gateway. The requirements of multiple propellant replenishments and extensive life operation have significant impacts on selection of the propulsion system concept and components for the RCS. The intent of this document is to provide insight into the government-reference conceptual design of a propulsion system for TH element. A pressure-fed hypergolic bi-propellant system is the assumed propulsion approach for the RCS. Its architectural concept is being traded within the NASA Moon to Mars architecture. A pressure-regulated system is examined. The propellants under consideration are Monomethyl Hydrazine (MMH) and Mixed Oxides of Nitrogen with 3% Nitric Oxide (MON3). A peer review was conducted to assess the flow schematic design and propulsion component selection, compliant with a set of assumed requirements. Redundant components to satisfy one-fault tolerance for function and two-fault tolerance against catastrophic events are incorporated in the propulsion concept design. Instrumentation laid out on the schematic would be used to gather data to monitor the health of the propulsion system and to support quantity gauging of the propulsion system fluids. Venting propellant ullage gas overboard during the refilling operations poses a significant concern to the external surfaces of the TH. A liquid/gas separator would be required to eliminate, or at least reduce, the amount of liquid propellant expelled in the vent gas mixture. The technology readiness level of the phase separator for the TH must be advanced. Metal diaphragm and non-positive-expulsion PMD propellant tank systems were traded against each other, with the PMD architecture being selected. A blowdown concept is also considered for the TH RCS propulsion. Its fluid schematic is derived from the pressure-regulated schematic with removal of assemblies involving the helium pressurization and ullage venting. Its system wet mass is 10% heavier than the pressure-regulated due to thruster performance loss and larger propellant tanks. There is no firm constraint on the propulsion system mass at this phase of the design. The blowdown concept can offer reduction in component count and operation, that would lead to a more reliable propulsion system. The blowdown concept would also benefit avionics, thermal, power, and structures on the TH. Assessing these benefits will be carried as a future work. Drawbacks of thrust and minimum impulse bit (MIB) variations due to the blowdown operation would be acceptable to Guidance, Navigation, and Control (GNC). Although the blowdown concept has been selected as a current baseline, further evaluation of the concept will be the subject of future work to ensure that the blowdown propulsion operation is appropriate for the HT RCS propulsion. This document also highlights key trade studies and design decisions, including pros and cons of the selected concept. Other appropriate options for components are pointed out for future assessments. Additional background information and documents for further review are referenced in this report.

spacecraft propulsion↗

GeoStorm Beacon Design Reference Mission (DRM) and Technology Drivers

A Design Reference Mission (DRM) for a NOAA Space Weather monitoring platform that provides warning times greater than 20 minutes with a 10-year operational timeline is presented. The summary of the DRM includes technology drivers for a subscale flight demonstration to reduce risk for the operational mission.

Solar Sails↗

Reference Model Development

Presentation from the 2011 Water Peer Review in which principal investigator discusses project progress to develop a representative set of Reference Models (RM) for the MHK industry to develop baseline cost of energy (COE) and evaluate key cost component/system reduction pathways.

cost↗

Radiation dose in coronary angiography and intervention: initial results from the establishment of a multi-centre diagnostic reference level in Queensland public hospitals

Radiation dose to patients undergoing invasive coronary angiography (ICA) is relatively high. Guidelines suggest that a local benchmark or diagnostic reference level (DRL) be established for these procedures. This study sought to create a DRL for ICA procedures in Queensland public hospitals. Data were collected for all Cardiac Catheter Laboratories in Queensland public hospitals. Data were collected for diagnostic coronary angiography (CA) and single-vessel percutaneous intervention (PCI) procedures. Dose area product (P{sub KA}), skin surface entrance dose (K{sub AR}), fluoroscopy time (FT), and patient height and weight were collected for 3 months. The DRL was set from the 75th percentile of the P{sub KA.} 2590 patients were included in the CA group where the median FT was 3.5 min (inter-quartile range = 2.3–6.1). Median K{sub AR} = 581 mGy (374–876). Median P{sub KA} = 3908 uGym{sup 2} (2489–5865) DRL = 5865 uGym{sup 2}. 947 patients were included in the PCI group where median FT was 11.2 min (7.7–17.4). Median K{sub AR} = 1501 mGy (928–2224). Median P{sub KA} = 8736 uGym{sup 2} (5449–12,900) DRL = 12,900 uGym{sup 2}. This study established a benchmark for radiation dose for diagnostic and interventional coronary angiography in Queensland public facilities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spark plasma sintering preparation of reference targets for field spectroscopy on Mars

We propose spark plasma sintering (SPS) as a technique to prepare reference targets for Raman and other spectroscopy instruments involved in future space missions and more generally in–field work. We have tested the effect of SPS on different international standards that are available in the form of minerals and rocks powders. Advantages and potential issues of SPS were considered by analyzing the Raman signal and mechanical properties of the sintered targets. The shape is well controlled; the rupture toughness is enhanced, and the homogeneous distribution of the mineral phases is verified. In conclusion, a suite of calibration targets has thus been implemented for the SuperCam instrument on the National Aeronautics and Space Administration Mars 2020 rover, and SPS may be preferred for future missions as well.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative methods and modeling to assess COVID–19–interrupted in vivo pharmacokinetic bioequivalence studies with two reference batches

The coronavirus disease 2019 (COVID-19) has presented unprecedented challenges to the generic drug development, including interruptions in bioequivalence (BE) studies. Per guidance published by the US Food and Drug Administration (FDA) during the COVID-19 public health emergency, any protocol changes or alternative statistical analysis plan for COVID-19-interrupted BE study should be accompanied with adequate justifications and not lead to biased equivalence determination. In this study, we used a modeling and simulation approach to assess the potential impact of study outcomes when two different batches of a Reference Standard (RS) were to be used in an in vivo pharmacokinetic BE study due to the RS expiration during the COVID-19 pandemic. Simulations were performed with hypothetical drugs under two scenarios: (1) uninterrupted study using a single batch of an RS, and (2) interrupted study using two batches of an RS. The acceptability of BE outcomes was evaluated by comparing the results obtained from interrupted studies with those from uninterrupted studies. The simulation results demonstrated that using a conventional statistical approach to evaluate BE for COVID-19-interrupted studies may be acceptable based on the pooled data from two batches. An alternative statistical method which includes a “batch” effect to the mixed effects model may be used when a significant “batch” effect was found in interrupted four-way crossover studies. However, such alternative method is not applicable for interrupted two-way crossover studies. Overall, the simulated scenarios are only for demonstration purpose, the acceptability of BE outcomes for the COVID19-interrupted studies could be case-specific.

60 APPLIED LIFE SCIENCES↗

Stable isotope analyses of oxygen ( 18 O: 17 O: 16 O) and chlorine ( 37 Cl: 35 Cl) in perchlorate: reference materials, calibrations, methods, and interferences

Perchlorate (ClO 4 - ) is a common trace constituent of water, soils, and plants; it has both natural and synthetic sources and is subject to biodegradation. The stable isotope ratios of Cl and O provide three independent quantities for ClO 4 - source attribution and natural attenuation studies: δ 37 Cl, δ 18 O, and δ 17 O (or Δ 17 O or 17 Δ) values. Finally, documented reference materials, calibration schemes, methods, and interferences will improve the reliability of such studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Additive manufacturing of platinum group element (PGE) reference materials with a silica matrix

The microanalytical community has an outstanding need for platinum group element (PGE) reference materials, particularly for trace element analysis by laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS). National Institute of Standards and Technology (NIST) glasses contain Rh, Pd, and Pt, but lack Ru, Os, and Ir. Synthesis of silicate PGE standards has proven difficult due the tendency of PGEs to form metallic nuggets. Additive manufacturing methods were used to produce PGE standards with a silica matrix. Monodispersed submicron PGE-doped Stöber particles were used as feedstock materials for electrophoretic deposition (EPD). Two-cm-sized samples produced by EPD were subsequently densified by thermal processing. The homogeneity of PGEs was tested using LA-ICPMS and concentrations were measured by laser ablation and solution ICPMS. The PGE concentrations ranged from 0.5 to 3 μg/g. The inhomogeneity was at the 3% RSD level for Ru, Rh, Ir, and Os throughout and 5% for Pt and Pd in the interior of the samples. Based on LA-ICPMS analyses, the interiors of the two samples have near identical concentrations in PGEs. The samples fabricated in this study represent the most complete and homogeneous PGE standards produced with a silicate matrix. The ability to produce multiple samples with the same composition provides opportunities for validating methods, monitoring long-term reproducibility, and facilitating interlaboratory comparisons.

36 MATERIALS SCIENCE↗

Reference scenarios for evaluating wood pellet production in the Southeastern United States

Wood pellet exports from the Southeastern United States (SE US) to Europe have been increasing in response to European Union member state policies to displace coal with renewable biomass for electricity generation. An understanding of the interactions among SE US forest markets, forest management, and forest ecosystem services is needed to quantify the effects of pellet production compared to what would be expected under a reference case or ‘counterfactual scenario’ without pellet production. Inconsistent methods to define and justify the counterfactual scenario result in conflicting estimates and large uncertainties about the impacts of pellet production on SE US forests. Guidelines to support more consistent and transparent counterfactual scenarios are proposed. The guidelines include identifying major influences on current SE US forest conditions, developing potential futures that clearly document underlying assumptions and associated uncertainties, identifying the most likely alternative feedstock fates, and estimating the effects of no pellet demand on future forest conditions. Finally, the guidelines can help modelers to more accurately reflect the past and current forest dynamics and to consider the implications for SE US forest landscapes of future scenarios with and without pellet production.

54 ENVIRONMENTAL SCIENCES↗

Validation of a DIXON-based fat quantification technique for the measurement of visceral fat using a CT-based reference standard

Purpose: The purpose of the study is to determine whether a novel semi-automated DIXON-based fat quantification algorithm can reliably quantify visceral fat using a CT-based reference standard. Methods: This was an IRB-approved retrospective cohort study of 27 subjects who underwent abdominopelvic CT within 7 days of proton density fat fraction (PDFF) mapping on a 1.5T MRI. Cross-sectional visceral fat area per slice (cm{sup 2}) was measured in blinded fashion in each modality at intervertebral disc levels from T12 to L4. CT estimates were obtained using a previously published semi-automated computational image processing system that sums pixels with attenuation − 205 to − 51 HU. MR estimates were obtained using two novel semi-automated DIXON-based fat quantification algorithms that measure visceral fat area by spatially regularizing non-uniform fat-only signal intensity or de-speckling PDFF 2D images and summing pixels with PDFF ≥ 50%. Pearson’s correlations and Bland–Altman analyses were performed. Results: Visceral fat area per slice ranged from 9.2 to 429.8 cm{sup 2} for MR and from 1.6 to 405.5 cm{sup 2} for CT. There was a strong correlation between CT and MR methods in measured visceral fat area across all studied vertebral body levels (r = 0.97; n = 101 observations); the least (r = 0.93) correlation was at T12. Bland–Altman analysis revealed a bias of 31.7 cm{sup 2} (95% CI [− 27.1]–90.4 cm{sup 2}), indicating modestly higher visceral fat assessed by MR. Conclusion: MR- and CT-based visceral fat quantification are highly correlated and have good cross-modality reliability, indicating that visceral fat quantification by either method can yield a stable and reliable biomarker.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient Dose Reference Levels for Interventional Radiology: A National Approach

A set of patient dose reference levels (RLs) for fluoroscopically guided interventional procedures was obtained in a survey launched by the National Society of Interventional Radiology (IR), involving 10 public hospitals, as recommended by the European Medical Exposures Directive. A sample of 1391 dose values (kerma area product [KAP]) was collected randomly during clinical procedures for seven of the most frequent procedures. Third quartiles of the KAP distributions were used to set the RLs. A regular quality control of the X-ray systems and a calibration of the dose meters were performed during the survey. The fluoroscopy time and total number of digital subtraction angiography images per procedure were also analyzed. The RL values proposed were 12 Gy cm{sup 2} for fistulography (hemodialysis access; sample of 180 cases), 73 Gy cm{sup 2} for lower limb arteriography (685 cases), 89 Gy cm{sup 2} for renal arteriography (55 cases), 80 Gy cm{sup 2} for biliary drainage (205 cases), 289 Gy cm{sup 2} for hepatic chemoembolization (151 cases), 94 Gy cm{sup 2} for iliac stent (70 cases), and 236 Gy cm{sup 2} for uterine embolization (45 cases). The provisional national RL values are lower than those obtained in a similar survey carried out in the United States from 2002 to 2004. These new values could be used to improve the practice of centers consistently working with doses higher than the RLs. This national survey also had a positive impact, as it helped increase the awareness of the members of the National Society of IR on a topic as crucial as patient dose values and programs on radiation protection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient Dose During Carotid Artery Stenting With Embolic-Protection Devices: Evaluation With Radiochromic Films and Related Diagnostic Reference Levels According to Factors Influencing the Procedure

To measure the maximum entrance skin dose (MESD) on patients undergoing carotid artery stenting (CAS) using embolic-protection devices, to analyze the dependence of dose and exposure parameters on anatomical, clinical, and technical factors affecting the procedure complexity, to obtain some local diagnostic reference levels (DRLs), and to evaluate whether overcoming DRLs is related to procedure complexity. MESD were evaluated with radiochromic films in 31 patients (mean age 72 {+-} 7 years). Five of 33 (15 %) procedures used proximal EPD, and 28 of 33 (85 %) procedures used distal EPD. Local DRLs were derived from the recorded exposure parameters in 93 patients (65 men and 28 women, mean age 73 {+-} 9 years) undergoing 96 CAS with proximal (33 %) or distal (67 %) EPD. Four bilateral lesions were included. MESD values (mean 0.96 {+-} 0.42 Gy) were <2 Gy without relevant dependence on procedure complexity. Local DRL values for kerma area product (KAP), fluoroscopy time (FT), and number of frames (N{sub FR}) were 269 Gy cm{sup 2}, 28 minutes, and 251, respectively. Only simultaneous bilateral treatment was associated with KAP (odds ratio [OR] 10.14, 95 % confidence interval [CI] 1-102.7, p < 0.05) and N{sub FR} overexposures (OR 10.8, 95 % CI 1.1-109.5, p < 0.05). Type I aortic arch decreased the risk of FT overexposure (OR 0.4, 95 % CI 0.1-0.9, p = 0.042), and stenosis {>=} 90 % increased the risk of N{sub FR} overexposure (OR 2.8, 95 % CI 1.1-7.4, p = 0.040). At multivariable analysis, stenosis {>=} 90 % (OR 2.8, 95 % CI 1.1-7.4, p = 0.040) and bilateral treatment (OR 10.8, 95 % CI 1.1-109.5, p = 0.027) were associated with overexposure for two or more parameters. Skin doses are not problematic in CAS with EPD because these procedures rarely lead to doses >2 Gy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗