Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reference Model 4”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Evaluation of the Event Driven Phenology Model Coupled with the VegET Evapotranspiration Model Through Comparisons with Reference Datasets in a Spatially Explicit Manner

A new model coupling scheme with remote sensing data assimilation was developed for estimation of daily actual evapotranspiration (ET). The scheme represents a mix of the VegET, a physically based model to estimate ET from a water balance, and an event driven phenology model (EDPM), where the EDPM is an empirically derived crop specific model capable of producing seasonal trajectories of canopy attributes. In this experiment, the scheme was deployed in a spatially explicit manner within the croplands of the Northern Great Plains. The evaluation was carried out using 2007-2009 land surface forcing data from the North American Land Data Assimilation System (NLDAS) and crop maps derived from remotely sensed data of NASA's Moderate Resolution Imaging Spectroradiometer (MODIS). We compared the canopy parameters produced by the phenology model with normalized difference vegetation index (NDVI) data derived from the MODIS nadir bi-directional reflectance distribution function (BRDF) adjusted reflectance (NBAR) product. The expectations of the EDPM performance in prognostic mode were met, producing determination coefficient (r2) of 0.8 +/-.0.15. Model estimates of NDVI yielded root mean square error (RMSE) of 0.1 +/-.0.035 for the entire study area. Retrospective correction of canopy dynamics with MODIS NDVI brought the errors down to just below 10% of observed data range. The ET estimates produced by the coupled scheme were compared with ones from the MODIS land product suite. The expected r2=0.7 +/-.15 and RMSE = 11.2 +/-.4 mm per 8 days were met and even exceeded by the coupling scheme0 functioning in both prognostic and retrospective modes. Minor setbacks of the EDPM and VegET performance (r2 about 0.5 and additional 30 % of RMSR) were found on the peripheries of the study area and attributed to the insufficient EDPM training and to spatially varying accuracy of crop maps. Overall the experiment provided sufficient evidence of soundness and robustness of the EDPM and VegET coupling scheme, assuring its potential for spatially explicit applications.

Kovalskyy, V.↗

Quantifying Medical Risk on a Long Duration Lunar Mission: A Demonstration of NASA’s IMPACT Tradespace Analysis Tool

Background NASA’s human exploration spaceflight missions to the Moon and Mars present unprecedented challenges for in-mission medical care. The distance from Earth will mean increased mission durations, communication delays, limited to no resupply opportunities, and constraints on the medical evacuation of astronauts. Mass, volume, power, and data will be limited while higher demands will be placed on the crew to manage medical care. NASA’s Moon to Mars exploration strategy lays out increasingly complex Artemis missions both in terms of duration and operations. In these more challenging deep space missions, it is important to quantitatively estimate the human medical risk to inform a traditional heuristic approach to medical risk. Prior tools have been developed for missions in low Earth orbit, but a new tool is required to plan for future exploration missions. Methods IMPACT (Informing Mission Planning via Analysis of Complex Tradespaces) is a risk assessment tool developed by NASA to advance exploration mission medical system design by quantitatively estimating mission medical risk. IMPACT v1.0 includes a novel evidence library baselined to exploration environments; an expanded list of 119 medical conditions; the addition of medical resources; and the ability for rapid and iterative analysis. Medical system risk estimates include loss of crew life, consideration of the need for return to definitive care (medical evacuation), and an estimate of crew time affected due to medical conditions. A notional long duration lunar orbit and lunar surface design reference mission (DRM) was chosen with a 4-astronaut crew to represent a sustained exploration Artemis mission. Results/Discussion Overall, IMPACT successfully quantified medical risk and derived an optimized medical system to support crew on a long duration lunar mission. In this DRM, the calculated loss of crew life from a medical event was 0.008 events per mission, risk of potential need for evacuation was 0.30 events per mission, and cumulative crew time affected by medical conditions was 103 days. The medical conditions that most contributed to overall medical risk were decompression sickness, trauma conditions, and respiratory failure. The conditions that had the largest effects on crew performance included musculoskeletal injuries and lunar dust exposure. The IMPACT-generated medical system included resources that target the most common and highest risk conditions. This systematic analysis demonstrates the value of the IMPACT tool in medical system design for human exploration spaceflight missions.

Missions to Mars↗

Quantifying Medical Risk on a Long Duration Lunar Mission: A Demonstration of NASA’s IMPACT Tradespace Analysis Tool

Background NASA’s human exploration spaceflight missions to the Moon and Mars present unprecedented challenges for in-mission medical care. The distance from Earth will mean increased mission durations, communication delays, limited to no resupply opportunities, and constraints on the medical evacuation of astronauts. Mass, volume, power, and data will be limited while higher demands will be placed on the crew to manage medical care. NASA’s Moon to Mars exploration strategy lays out increasingly complex Artemis missions both in terms of duration and operations. In these more challenging deep space missions, it is important to quantitatively estimate the human medical risk to inform a traditional heuristic approach to medical risk. Prior tools have been developed for missions in low Earth orbit, but a new tool is required to plan for future exploration missions. Methods IMPACT (Informing Mission Planning via Analysis of Complex Tradespaces) is a risk assessment tool developed by NASA to advance exploration mission medical system design by quantitatively estimating mission medical risk. IMPACT v1.0 includes a novel evidence library baselined to exploration environments; an expanded list of 119 medical conditions; the addition of medical resources; and the ability for rapid and iterative analysis. Medical system risk estimates include loss of crew life, consideration of the need for return to definitive care (medical evacuation), and an estimate of crew time affected due to medical conditions. A notional long duration lunar orbit and lunar surface design reference mission (DRM) was chosen with a 4-astronaut crew to represent a sustained exploration Artemis mission. Results/Discussion Overall, IMPACT successfully quantified medical risk and derived an optimized medical system to support crew on a long duration lunar mission. In this DRM, the calculated loss of crew life from a medical event was 0.008 events per mission, risk of potential need for evacuation was 0.30 events per mission, and cumulative crew time affected by medical conditions was 103 days. The medical conditions that most contributed to overall medical risk were decompression sickness, trauma conditions, and respiratory failure. The conditions that had the largest effects on crew performance included musculoskeletal injuries and lunar dust exposure. The IMPACT-generated medical system included resources that target the most common and highest risk conditions. This systematic analysis demonstrates the value of the IMPACT tool in medical system design for human exploration spaceflight missions.

Missions to Mars↗

Strategic Petroleum Reserve Cavern Leaching Monitoring CY21

Th e U.S. Strategic Petroleum Reserve (SPR) is a crude oil storage system administered by the U.S. Department of Energy. The reserve consists of 60 active storage caverns located in underground salt domes spread across four sites in Louisiana and Texas, near the Gulf of Mexico. Beginning in 2016, the SPR started executing C ongressionally mandated oil sales. The configuration of the reserve, with a total capacity of greater than 700 million barrels ( MMB ) , re quires that unsaturated water (referred to herein as ?raw? water) is injected into the storage caverns to displace oil for sales , exchanges, and drawdowns . As such, oil sales will produce cavern growth to the extent that raw water contacts the salt cavern walls and dissolves (leaches) the surrounding salt before reaching brine saturation. SPR injected a total of over 45 MMB of raw water into twenty - six caverns as part of oil sales in CY21 . Leaching effects were monitored in these caverns to understand how the sales operations may impact the long - term integrity of the caverns. While frequent sonars are the most direct means to monitor changes in cavern shape, they can be resource intensive for the number of caverns involved in sales and exchanges. An interm ediate option is to model the leaching effects and see if any concerning features develop. The leaching effects were modeled here using the Sandia Solution Mining Code , SANSMIC . The modeling results indicate that leaching - induced features do not raise co ncern for the majority of the caverns, 15 of 26. Eleven caverns, BH - 107, BH - 110, BH - 112, BH - 113, BM - 109, WH - 11, WH - 112, WH - 114, BC - 17, BC - 18, and BC - 19 have features that may grow with additional leaching and should be monitored as leaching continues in th ose caverns. Additionally, BH - 114, BM - 4, and BM - 106 were identified in previous leaching reports for recommendation of monitoring. Nine caverns had pre - and post - leach sonars that were compared with SANSMIC results. Overall, SANSMIC was able to capture the leaching well. A deviation in the SANSMIC and sonar cavern shapes was observed near the cavern floor in caverns with significant floor rise, a process not captured by SANSMIC. These results validate that SANSMIC continues to serve as a useful tool for mon itoring changes in cavern shape due to leaching effects related to sales and exchanges.

02 PETROLEUM↗

Modeling of Glycolate Destruction in the Recycle Collection Tank

The Savannah River Site’s DWPF is being upgraded with the introduction of the NG flowsheet. Glycolic acid has been shown to be a superior alternative to formic acid for sludge processing. The new flowsheet improves or maintains necessary parameters such as 1) reduction of mercury, 2) adjustment of feed rheology, 3) pH stability, and 4) adjustment of melter oxidation/reduction potential. Further, the use of glycolic acid virtually eliminates the potential for catalytic hydrogen generation in DWPF processing DWPF process condensates are collected and returned to the Savannah River Site (SRS) CSTF. The RCT collects off-gas condensate during chemical processing, vitrification, and other unit operations performed in DWPF and is the singular return vessel delivering recycle effluent back to CSTF. Each batch of recycle will have a small amount of glycolate from chemical processing and melter off-gas condensates. To avoid potential flammability issues due to thermolysis of glycolate in the CSTF, Savannah River National Laboratory (SRNL) provided to Savannah River Remediation (SRR) at their request a Task Technical and Quality Assurance Plan (TTQAP) to quantify and mitigate glycolate returns via DWPF’s recycle stream. The request included testing of a process to oxidize glycolate and other organic species that are responsible for hydrogen generation from thermolysis. Following that work SRR provided a Task Technical Request (TTR) that requested process modeling. In 2021 a TTQAP was issued to cover the modeling work. Modeling draws data from laboratory scale studies using chemical simulants and radioactive waste samples. Chemical kinetic modeling was performed to evaluate the feasibility of using sodium permanganate to destroy glycolate in the RCT. The results from the laboratory studies were summarized in a series of reports. Reference 9 is a report of lab scale processing of actual DWPF Slurry Mix Evaporate Condensate Tank (SMECT) and Offgas Condensate Tank (OGCT) samples in the SRNL Shielded Cells. Tests at caustic conditions demonstrated sodium permanganate was effective in converting glycolate to oxalate, and permanganate (Mn 7+ ) is reduced to manganate (Mn 6+ ) with no significant formation of carbon dioxide or carbonate. Equation (1) was found to best describe the observed reaction of glycolate with permanganate under nominal (60 to 145 mg/L in RCT) glycolate entrainment conditions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development and Testing of Pulse Guns for Combustion Instability Testing

To test liquid rocket engines (LREs) for combustion instabilities, devices such as bombs are often used to create pressure wave disturbances. Bombs, while effective, are inherently dangerous, expensive, and difficult to procure. Over the years, pulse guns have been used as a safer and more cost-effective way to generate controlled pressure disturbances in engine chambers. In anticipation of the need for stability testing of prototype LREs at NASA Marshall Space Flight Center (MSFC), a set of pulse guns have been designed, fabricated, tested, and characterized. The pulse gun program is funded by the RS-25 Engine Program managed out of MSFC and funded by NASA’s Space Launch System (SLS) through the MSFC Liquid Engines Office (LEO). A pulse gun is a simple device – like a traditional gun, it has a breech and barrel section. However, unlike a traditional gun, there is no bullet, as the purpose of the pulse gun is strictly to fire a high pressure pulse. Instead of a firing pin and primer that would normally be used in a traditional gun, an initiator is used to activate the gun powder. The initiator is a highly reliable pyrotechnic initiator. For this study, clone versions of the NASA Standard Initiator (NSI) were used. The initiator is used to ignite a pre-measured amount of gun powder loaded into the breech. When the pressure of the burnt gun powder exceeds the set point of a downstream burst disk, the disk ruptures, allowing the high pressure pulse to travel downstream through the barrel section. A ballistic pressure transducer located in the breech section is used to measure the short duration, high pressure pulse. Some configurations of the pulse gun have barrel sections that include one or more additional ballistic pressure transducers. These additional pressure measurements help track the degradation and damping of the pulse as it travels out of the barrel section. The measurements may also be used to determine the velocity of pulse. The objective of this paper is to present the different variants of this newly-developed pulse gun and characterize performance over a range of parameters. The parameters include breech diameter, barrel length, amount of gun powder used, the way the gun powder is packed, and the pressure setting of the burst disk. There are a total of six pulse guns: three with the 0.25 inch breech and three different length barrels, and three with the 0.40 inch breech and three different length barrels. For both breech sizes, the associated barrels are referred to as standard, one-port, and two-port barrels. The standard barrel has no instrumentation and is likely the barrel that will be used for engine stability testing. The one- and two-port barrels were designed specifically for pulse gun component testing to allow measurements of the magnitude and timing of the high pressure pulse as it makes its way through the pulse gun. The burst disks tested were commercially-available burst disks designed to rupture at 8,000, 16,000, and 24,000 psid. Testing was accomplished by firing the pulse gun into a test chamber pressurized with nitrogen at about 2300 psig. A total of four Model 113B23 High frequency ICP® pressure sensors (10k psi) were mounted in the test chamber, in the same plane as the pulse gun. Two of the sensors had “trimmed” adapters, and two did not. Given the symmetrical configuration of the sensors within the test chamber, different amplitudes of pressure measurements are attributed to the use of trimmed versus untrimmed adapters. The untrimmed adapters, with their narrower passages, tended to amplify the pressure amplitudes by as much as 50%. In total, 41 pulse gun tests have been conducted.Data are still being analyzed, but some trends are apparent. For example, measurements taken within the pulse gun are shown in Figures 3 and 4 for Hot-fires (HFs) # 11 and 39, respectively. Both tests were identical in that the 0.40 inch ID breech, two-port barrel, 8,000 psid burst disk, and same amount of gunpowder (6.639 grains for HF# 11, and 6.576 grains for HF# 39) were used, and the back pressure in the nitrogen test chamber was ~2300 psig. Despite keeping all these variables constant, the results from these two tests look quite different. For both tests, the first pressure peak shown in the P2111 trace within the breech is the firing of the initiator. The second peak and any subsequent peaks are from the combustion of the gunpowder. It should be noted that because the sensors are dynamic, the ~2300 psig baseline static pressure is not shown in the figures. For HF# 11, the burst disk clearly ruptured in a little over 0.1 ms from the time the initiator was fired. This is evident from the abrupt rise in pressure for P2112 followed by another abrupt rise in pressure for P2113. The sensors track the movement of the high pressure pulse through the pulse gun. For HF# 39, however, there was nearly 1 ms delay between the initiator firing and the burst disk rupturing. The only difference between these two tests was the way in which the gunpowder was packed within the breech. For HF# 11, the gunpowder was poured directly into the breech, atop the initiator, and held in place with a vegetable fiber wad appropriately sized for the barrel diameter. Once in place, the wad firmly held the gunpowder in place. For HF# 39, the gunpowder was rolled within cigarette paper with the ends of the paper twisted. The rolled gunpowder was gently pushed down into the breech, toward the initiator, and no wad was used. This method of loading the gunpowder consistently produced longer delays in the rupture of the burst disk, presumably because there was a steady, fuller burning of the gunpowder. The burst disk was rated for 8,000 psid, which means that the burst disk should not have opened until the pressure in the breech reached ~10,300 since there was ~2300 psig back pressure in the test chamber. In the case of HF# 11, the breech pressure only reached roughly 4200 psi before there was leakage either through or past the burst disk, but for HF#39, the breech pressure reached 10,600 psi prior to the burst disk opening. The temperature of the burst disk is certainly a factor in determining when the burst disk will rupture. A sharp rise in the burst disk temperature could weaken it and cause it to stray from the designed set point burst pressure. The burst disks are manufactured of Inconel to try to reduce their sensitivity to temperature, but how the burst disks perform above 900°F is not documented. All burst disks were engineered and tested by the manufacturer for ambient temperature conditions. One theory for why rolling the gunpowder in cigarette paper may produce better results is related to a more controlled temperature environment. The cigarette paper may act as a sheath that protects the burst disk from excessive temperatures during the rapid buildup of pressure in the breech. The ultimate benefit of not breeching the burst disk prematurely is shown in Figures 5 and 6, which graphs the resultant pressure pulse produced in the test chamber. For HF #11, the peak pressure on the P2123 trimmed adapter is about 270 psi, while for HF# 39 it is 343 psi, which is about 1.27 times greater in magnitude. In either case, the pressure pulse is ~20 μs in width once it reaches the test chamber. Another pressure rise about 100 μs later can be seen on the sensors located across from the pulse gun port, P2124 and P2121. These pressures are lower due to attenuation of the pressure wave as it moves across the test chamber. After the wave encounters the wall, it reflects back and forth within the chamber until it completely dissipates.

Pulse Gun↗

Rotational stabilization of the resistive wall modes in tokamaks with a ferritic wall

The dynamics of the rotating resistive wall modes (RWMs) is analyzed in the presence of a uniform ferromagnetic resistive wall with μ{sup ^}≡μ/μ{sub 0}≤4 (μ is the wall magnetic permeability, and μ{sub 0} is the vacuum one). This mimics a possible arrangement in ITER with ferromagnetic steel in test blanket modules or in future experiments in JT-60SA tokamak [Y. Kamada, P. Barabaschi, S. Ishida, the JT-60SA Team, and JT-60SA Research Plan Contributors, Nucl. Fusion 53, 104010 (2013)]. The earlier studies predict that such a wall must provide a destabilizing influence on the plasma by reducing the beta limit and increasing the growth rates, compared to the reference case with μ{sup ^}=1. This is true for the locked modes, but the presented results show that the mode rotation changes the tendency to the opposite. At μ{sup ^}>1, the rotational stabilization related to the energy sink in the wall becomes even stronger than at μ{sup ^}=1, and this “external” effect develops at lower rotation frequency, estimated as several kHz at realistic conditions. The study is based on the cylindrical dispersion relation valid for arbitrary growth rates and frequencies. This relation is solved numerically, and the solutions are compared with analytical dependences obtained for slow (s/d{sub w}≫1) and fast (s/d{sub w}≪1) “ferromagnetic” rotating RWMs, where s is the skin depth and d{sub w} is the wall thickness. It is found that the standard thin-wall modeling becomes progressively less reliable at larger μ{sup ^}, and the wall should be treated as magnetically thick. The analysis is performed assuming only a linear plasma response to external perturbations without constraints on the plasma current and pressure profiles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Monte Carlo evaluation of the convolution/superposition algorithm of Hi-Art tomotherapy in heterogeneous phantoms and clinical cases

The reliability of the convolution/superposition (C/S) algorithm of the Hi-Art tomotherapy system is evaluated by using the Monte Carlo model TomoPen, which has been already validated for homogeneous phantoms. The study was performed in three stages. First, measurements with EBT Gafchromic film for a 1.25x2.5 cm{sup 2} field in a heterogeneous phantom consisting of two slabs of polystyrene separated with Styrofoam were compared to simulation results from TomoPen. The excellent agreement found in this comparison justifies the use of TomoPen as the reference for the remaining parts of this work. Second, to allow analysis and interpretation of the results in clinical cases, dose distributions calculated with TomoPen and C/S were compared for a similar phantom geometry, with multiple slabs of various densities. Even in conditions of lack of lateral electronic equilibrium, overall good agreement was obtained between C/S and TomoPen results, with deviations within 3%/2 mm, showing that the C/S algorithm accounts for modifications in secondary electron transport due to the presence of a low density medium. Finally, calculations were performed with TomoPen and C/S of dose distributions in various clinical cases, from large bilateral head and neck tumors to small lung tumors with diameter of <3 cm. To ensure a ''fair'' comparison, identical dose calculation grid and dose-volume histogram calculator were used. Very good agreement was obtained for most of the cases, with no significant differences between the DVHs obtained from both calculations. However, deviations of up to 4% for the dose received by 95% of the target volume were found for the small lung tumors. Therefore, the approximations in the C/S algorithm slightly influence the accuracy in small lung tumors even though the C/S algorithm of the tomotherapy system shows very good overall behavior.

61 RADIATION PROTECTION AND DOSIMETRY↗

Development of a water calorimetry-based standard for absorbed dose to water in HDR {sup 192}Ir brachytherapy

Purpose: The aim of this article is to develop and evaluate a primary standard for HDR {sup 192}Ir brachytherapy based on 4 deg. C stagnant water calorimetry. Methods: The absolute absorbed dose to water was directly measured for several different Nucletron microSelectron {sup 192}Ir sources of air kerma strength ranging between 21 000 and 38 000 U and for source-to-detector separations ranging between 25 and 70 mm. The COMSOL MULTIPHYSICS software was used to accurately calculate the heat transport in a detailed model geometry. Through a coupling of the ''conduction and convection'' module with the ''Navier-Stokes incompressible fluid'' module in the software, both the conductive and convective effects were modeled. Results: A detailed uncertainty analysis resulted in an overall uncertainty in the absorbed dose of 1.90%(1{sigma}). However, this includes a 1.5% uncertainty associated with a nonlinear predrift correction which can be substantially reduced if sufficient time is provided for the system to come to a new equilibrium in between successive calorimetric runs, an opportunity not available to the authors in their clinical setting due to time constraints on the machine. An average normalized dose rate of 361{+-}7 {mu}Gy/(h U) at a source-to-detector separation of 55 mm was measured for the microSelectron {sup 192}Ir source based on water calorimetry. The measured absorbed dose per air kerma strength agreed to better than 0.8%(1{sigma}) with independent ionization chamber and EBT-1 Gafchromic film reference dosimetry as well as with the currently accepted AAPM TG-43 protocol measurements. Conclusions: This work paves the way toward a primary absorbed dose to water standard in {sup 192}Ir brachytherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Predictive role of PI-RADSv2 and ADC parameters in differentiating Gleason pattern 3 + 4 and 4 + 3 prostate cancer

Purpose: To compare the predictive roles of qualitative (PI-RADSv2) and quantitative assessment (ADC metrics), in differentiating Gleason pattern (GP) 3 + 4 from the more aggressive GP 4 + 3 prostate cancer (PCa) using radical prostatectomy (RP) specimen as the reference standard. Methods: We retrospectively identified treatment-naïve peripheral (PZ) and transitional zone (TZ) Gleason Score 7 PCa patients who underwent multiparametric 3T prostate MRI (DWI with b value of 0,1400 and where unavailable, 0,500) and subsequent RP from 2011 to 2015. For each lesion identified on MRI, a PI-RADSv2 score was assigned by a radiologist blinded to pathology data. A PI-RADSv2 score ≤ 3 was defined as “low risk,” a PI-RADSv2 score ≥ 4 as “high risk” for clinically significant PCa. Mean tumor ADC (ADC{sub T}), ADC of adjacent normal tissue (ADC{sub N}), and ADC{sub ratio} (ADC{sub T}/ADC{sub N}) were calculated. Stepwise regression analysis using tumor location, ADC{sub T} and ADC{sub ratio}, b value, low vs. high PI-RADSv2 score was performed to differentiate GP 3 + 4 from 4 + 3. Results: 119 out of 645 cases initially identified met eligibility requirements. 76 lesions were GP 3 + 4, 43 were 4 + 3. ADC{sub ratio} was significantly different between the two GP groups (p = 0.001). PI-RADSv2 score (“low” vs. “high”) was not significantly different between the two GP groups (p = 0.17). Regression analysis selected ADC{sub T} (p = 0.03) and ADC{sub ratio} (p = 0.0007) as best predictors to differentiate GP 4 + 3 from 3 + 4. Estimated sensitivity, specificity, and accuracy of the predictive model in differentiating GP 4 + 3 from 3 + 4 were 37, 82, and 66%, respectively. Conclusions: ADC metrics could differentiate GP 3 + 4 from 4 + 3 PCa with high specificity and moderate accuracy while PI-RADSv2, did not differentiate between these patterns.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modelling the Impact of Fractionation on Late Urinary Toxicity After Postprostatectomy Radiation Therapy

Purpose: To fit urinary toxicity data of patients treated with postprostatectomy radiation therapy with the linear quadratic (LQ) model with/without introducing a time factor. Methods and Materials: Between 1993 and 2010, 1176 patients were treated with conventional fractionation (1.8 Gy per fraction, median 70.2 Gy, n=929) or hypofractionation (2.35-2.90 Gy per fraction, n=247). Data referred to 2004-2010 (when all schemes were in use, n=563; conventional fractionation: 316; hypofractionation: 247) were fitted as a logit function of biological equivalent dose (BED), according to the LQ model with/without including a time factor γ (fixing α/β = 5 Gy). The 3-year risks of severe urethral stenosis, incontinence, and hematuria were considered as endpoints. Best-fit parameters were derived, and the resulting BEDs were taken in multivariable backward logistic models, including relevant clinical variables, considering the whole population. Results: The 3-year incidences of severe stenosis, incontinence, and hematuria were, respectively, 6.6%, 4.8%, and 3.3% in the group treated in 2004-2010. The best-fitted α/β values were 0.81 Gy and 0.74 Gy for incontinence and hematuria, respectively, with the classic LQ formula. When fixing α/β = 5 Gy, best-fit values for γ were, respectively, 0.66 Gy/d and 0.85 Gy/d. Sensitivity analyses showed reasonable values for γ (0.6-1.0 Gy/d), with comparable goodness of fit for α/β values between 3.5 and 6.5 Gy. Likelihood ratio tests showed that the fits with/without including γ were equivalent. The resulting multivariable backward logistic models in the whole population included BED, pT4, and use of antihypertensives (area under the curve [AUC] = 0.72) for incontinence and BED, pT4, and year of surgery (AUC = 0.80) for hematuria. Stenosis data could not be fitted: a 4-variable model including only clinical factors (acute urinary toxicity, pT4, year of surgery, and use of antihypertensives) was suggested (AUC = 0.73). Conclusions: The unexpected impact of moderate hypofractionation on severe incontinence and hematuria after postprostatectomy radiation therapy may be explained by a bladder α/β value <1 Gy or, radiobiologically more plausible, by introducing a time factor likely to represent a previously hypothesized consequential component of late effect.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rationalizing the suitability of rhodamines as chromophores in dye-sensitized solar cells: A systematic molecular design study

Here, rhodamines are chromophores that are employed in many dye applications. Their strong optical absorption in the visible region of the electromagnetic spectrum renders them attractive dye candidates for dye-sensitized solar cells (DSCs). However, they have not yet been systematically tested in DSCs as single- or co-sensitizers. Recent advances in concerted experimental and computational workflows involving molecular design protocols can afford a better understanding of the molecular origins of the optoelectronic properties in these sensitizers. Herein, we examine the suitability of rhodamines R560 (1), R575 (2), R590 (3), R610 (4), R620 (5), R640 (6), and R3B (7) as chromophores in co-sensitized DSCs. Our study follows a stepwise approach. Initially, structural and optical properties of the dyes are investigated by experimental and computational methods to reveal structure-property relationships and other useful features for DSC applications. Subsequently, 1-7 are investigated at the dye···TiO 2 interface, both by calculations of dye-adsorption onto the surface of a modeled (TiO 2 ) 9 cluster, and by experimental studies of dye-adsorption on TiO 2 . For that purpose, a selection of rhodamine dyes are paired together (1 and 5) and (1 and 7) for co-sensitization, among which 5 is also co-adsorbed with a fluorescein dye in order to explore chemical compatibility factors. The best dye candidates are identified from the findings of these adsorption studies in terms of dye aggregation, anchoring modes, and panchromatic response. Despite their promising dye…TiO 2 adsorption and optical prospects, our results show that rhodamines lack a suitable intramolecular charge transfer pathway for dye-to-TiO 2 electron injection to occur, thus precluding their photovoltaic function as DSC dyes. Our results are then assessed against ostensibly disparate reports of rhodamines performing successfully in DSC devices; this comparison necessitated the internal reproduction of previously reported co-sensitization experiments on 2 with the industrial standard reference dye, N3. We achieve reconciliation between our results and those in the literature by reasoning that while rhodamines cannot deliver photovoltaic function in DSCs in their own right, they can either act to facilitate or deplete the photovoltaic output of a DSC indirectly by affecting the TiO 2 adsorption prospects of a photovoltaic-active dye with which a rhodamine is co-sensitized.

14 SOLAR ENERGY↗

Automated Processing of ISIS Topside Ionograms into Electron Density Profiles

Modeling of the topside ionosphere has for the most part relied on just a few years of data from topside sounder satellites. The widely used Bent et al. (1972) model, for example, is based on only 50,000 Alouette 1 profiles. The International Reference Ionosphere (IRI) (Bilitza, 1990, 2001) uses an analytical description of the graphs and tables provided by Bent et al. (1972). The Alouette 1, 2 and ISIS 1, 2 topside sounder satellites of the sixties and seventies were ahead of their times in terms of the sheer volume of data obtained and in terms of the computer and software requirements for data analysis. As a result, only a small percentage of the collected topside ionograms was converted into electron density profiles. Recently, a NASA-funded data restoration project has undertaken and is continuing the process of digitizing the Alouette/ISIS ionograms from the analog 7-track tapes. Our project involves the automated processing of these digital ionograms into electron density profiles. The project accomplished a set of important goals that will have a major impact on understanding and modeling of the topside ionosphere: (1) The TOPside Ionogram Scaling and True height inversion (TOPIST) software was developed for the automated scaling and inversion of topside ionograms. (2) The TOPIST software was applied to the over 300,000 ISIS-2 topside ionograms that had been digitized in the fkamework of a separate AISRP project (PI: R.F. Benson). (3) The new TOPIST-produced database of global electron density profiles for the topside ionosphere were made publicly available through NASA s National Space Science Data Center (NSSDC) ftp archive at . (4) Earlier Alouette 1,2 and ISIS 1, 2 data sets of electron density profiles from manual scaling of selected sets of ionograms were converted fiom a highly-compressed binary format into a user-friendly ASCII format and made publicly available through nssdcftp.gsfc.nasa.gov. The new database for the topside ionosphere established as a result of this project, has stimulated a multitude of new studies directed towards a better description and prediction of the topside ionosphere. Marinov et al. (2004) developed a new model for the upper ion transition height (Oxygen to Hydrogen and Helium) and Bilitza (2004) deduced a correction term for the I N topside electron density model. Kutiev et al. (2005) used this data to develop a new model for the topside ionosphere scale height (TISH) as a function of month, local time, latitude, longitude and solar flux F10.7. Comparisons by Belehaki et al. (2005) show that TISH is in general agreement with scale heights deduced from ground ionosondes but the model predicts post-midnight and afternoon maxima whereas the ionosonde data show a noon maximum. Webb and Benson (2005) reported on their effort to deduce changes in the plasma temperature and ion composition from changes in the topside electron density profile as recorded by topside sounders. Limitations and possible improvements of the IRI topside model were discussed by Coisson et al. (2005) including also the possible use of the NeQuick model, Our project progressed in close collaboration and coordination with the GSFC team involved in the ISIS digitization effort. The digitization project was highly successful producing a large amount of digital topside ionograms. Several no-cost extensions of the TOPIST project were necessary to keep up with the pace and volume of the digitization effort.

Reinisch, bodo W.↗

High Spin Baryons in Quantum Mechanical Chromodynamics

A framework of quantum mechanical chromodynamics (QMCD) is developed with the aim to place the description of the nucleon on a comparable footing with Schroedinger's quantum mechanical treatment of the hydrogen atom. Such indeed turns out to be possible upon replacing the (e{sup -}-p) by a (q-qq) system, on the one hand, and the Coulomb potential by the recently reported by us exactly solvable trigonometric extension of the Cornell (TEC) potential, on the other. The TEC potential translates the inverse distance potential in ordinary flat space to a space of constant positive curvature, the 3D hypersphere, a reason for which both potentials have the SO(4) and SO(2, 1) symmetries in common. In effect, the nucleon spectrum, inclusive its {delta} branch, acquire the degeneracy patterns of the electron excitations with spin in {sup 1}H without copying them, however. There are two essential differences between the N({delta}) and H atom spectra. The first concerns the parity of the states which can be unnatural for the N and {delta} excitations due to compositeness of the diquark, the second refers to the level splittings in the baryon spectra which contain besides the Balmer term also its inverse of opposite sign. Our scheme reproduces the complete number of states (except the hybrid {delta}(1600)), predicts a total of 33 new resonances, and explains the splittings of the N and {delta} levels containing high-spin resonances. It also describes accurately the proton electric charge form factor. We here calculate the potential in momentum space (instantaneous effective gluon propagator) as a Fourier transform of the TEC potential and show that the concept of curvature allows to avoid the integral divergences suffered by schemes based on power potentials. We find a propagator that is finite at origin, likely to produce confinement. The advocated new potential picture allows for deconfinement too as effect of space flattening in the limit of infinite radius of the 3D hypersphere. The potential's SO(4)/SO(2, 1) symmetries reflect AdS{sub 5}/CFT correspondence.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Independent amplitude approximations in coupled cluster valence bond theory: Incorporation of 3-electron-pair correlation and application to spin frustration in the low-lying excited states of a ferredoxin-type tetrametallic iron-sulfur cluster

We report that coupled cluster valence bond (CCVB) is a simple electronic structure method based on a perfect pairing (PP) reference with 2-pair recouplings for strong electron correlation problems. CCVB is spin-pure, size-consistent, and can exactly (in its active space) separate any molecule into atoms for which unrestricted Hartree-Fock (UHF) at dissociation is the sum of the ground state UHF energies of the atoms. However CCVB is far from a complete description of strong correlations. Its first failure to exactly describe spin-recouplings arises at the level of 3 electron pairs, such as the recoupling of 3 triplet oxygen atoms in the dissociation of singlet ozone. Such situations are often associated with spin frustration. To address this limitation, an extension of CCVB, termed CCVB+i3, is reported here that includes an independent (i) amplitude approximation to the 3-pair recouplings. CCVB+i3 thereby has the same basic computational requirements as those of CCVB, which has previously been shown to be an efficient method. CCVB+i3 correctly separates molecules that CCVB cannot. As a by-product, an independent 2-pair amplitude approximation to CCVB, called PP+i2, is also defined. Remarkably, PP+i2 can also correctly separate systems that CCVB cannot. CCVB+i3 is validated on the symmetric dissociation of D 3h ozone. CCVB+i3 is then used to explore the role of 3-pair recouplings in an [Fe 4 S 4 (SCH 3 ) 4 ] 2- cluster that has been used to model the iron-sulfur core of [Fe 4 S 4 ] ferredoxins. Using localized PP orbitals, such recouplings are demonstrated to be large in some low-lying singlet excited states of the cluster. Lastly, significant 3 pair recoupling amplitudes include the usual triangular motif associated with spin frustration and other geometric arrangements of the 3 entangled pairs across the 4 iron centers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mean sea surface and geoid gradient comparisons with TOPEX altimeter data

Cycles 4 to 54 of TOPEX data have been analyzed through comparisons with the mean sea surface given on the disturbed geophysical data record (GDR). Two inverted barometer correction procedures were considered for the data reduction. One used a constant atmospheric pressure for all data while the one adopted for use, for most computations, introduced a cycle average pressure. The maximum difference between the two estimates was 3.0 cm with a clear annual signal. With the modified correction the TOPEX sea surface was compared to The Ohio State University (OSU) mean sea surface, given on the GDR, to estimate three translations ( delta x = -2.3 cm; delta y = 25.0 cm; delta z = -0.3 cm) and a bias (43.3 cm) between the two surfaces. The only significant translation is delta y which indicates the reference frame of the TOPEX system differs from that used in the OSU mean sea surface system. The bias between the TOPEX mean sea surface and the OSU mean sea surface was used to estimate an equatorial radius of 6,378,136.55 m based on an 18-cm biased estimate of the TOPEX altimeter. Examination of the average difference, by cycle, between the TOPEX sea surface and the OSU mean sea surface suggested a bias change of 3.1 +/- 2.2 mm/yr with a positive sign indicating the average ocean surface is rising or the altimeter measured distance is decreasing. Models were implemented that solved directly for a bias, bias rate annual/semiannual, and tide correction terms. The computations indicated that a simultaneous solution for this bias, bias rate, and annual/semiannual terms gave the most accurate results. Nonsimultaneous solutions led to slightly different bias rate values. The root mean square difference between the TOPEX sea surface and OSU sea surface, after translation and bias correction, was +/- 17 cm for a typical cycle. Some locations were indentified where the difference could reach 2.3 cm and were repeated over several cycles indicating errors in the mean sea surface. Most of the large differences occur in regions lacking altimeter data prior to the TOPEX/POSEIDON mission and/or areas of significant bathymetric signature. Geoid gradients are needed for the reduction of individual track data to a reference track. The accuracy of the determination of such gradients was determined through the comparison of predicted along-track gradients to the observed gradients. Among four mean sea surfaces tested the best agreement was found with the OSU mean sea surface placed on the TOPEX geophysical data record.

Rapp, Richard H.↗

LOCO with Constraints and Improved Fitting Technique

LOCO has been a powerful beam-based diagnostics and optics control method for storage rings and synchrotrons worldwide ever since it was established at NSLS by J. Safranek. This method measures the orbit response matrix and optionally the dispersion function of the machine. The data are then fitted to a lattice model by adjusting parameters such as quadrupole and skew quadrupole strengths in the model, BPM gains and rolls, corrector gains and rolls of the measurement system. Any abnormality of the machine that affects the machine optics can then be identified. The resulting lattice model is equivalent to the real machine lattice as seen by the BPMs. Since there are usually two or more BPMs per betatron period in modern circular accelerators, the model is often a very accurate representation of the real machine. According to the fitting result, one can correct the machine lattice to the design lattice by changing the quadrupole and skew quadrupole strengths. LOCO is so important that it is routinely performed at many electron storage rings to guarantee machine performance, especially after the Matlab-based LOCO code became available. However, for some machines, LOCO is not easy to carry out. In some cases, LOCO fitting converges to an unrealistic solution with large changes to the quadrupole strengths {Delta}K. The quadrupole gradient changes can be so large that the resulting lattice model fails to find a closed orbit and subsequent iterations become impossible. In cases when LOCO converges, the solution can have {Delta}K that is larger than realistic and often along with a spurious zigzag pattern between adjacent quadrupoles. This degeneracy behavior of LOCO is due to the correlation between the fitting parameters - usually between neighboring quadrupoles. The fitting scheme is therefore less restrictive over certain patterns of changes to these quadrupoles with which the correlated quadrupoles fight each other and the net effect is very inefficient {chi}{sup 2} reduction, i.e., small {chi}{sup 2} reduction with large changes of {Delta}K. Under effects of random noise, the fitting solution tends to crawl toward these patterns and ends up with unrealistically large {Delta}K. Such a solution is not very useful in optics correction because after the solution is dialed in, the quadrupoles will not respond as predicted by the lattice model due to magnet hysteresis. We will show that adding constraints to the fitting parameters is an effective way to combat this problem of LOCO. In fact, it improves optics calibration precision even for machines that don't show severe degeneracy behavior. LOCO fitting is essentially to solve a nonlinear least square problem with an iterative approach. The linear least square technique is applied in each iteration to move the solution toward the minimum. This approach is commonly referred to as the Gauss-Newton method. By using singular value decomposition (SVD) to invert the Jacobian matrix, this method has generally been very successful for LOCO. However, this method is based on a linear expansion of the residual vector over the fitting parameters which is valid only when the starting solution is sufficiently close to the real minimum. The fitting algorithm can have difficulties to converge when the initial guess is too far off. For example, it's possible for the {chi}{sup 2} merit function to increase after an iteration instead of decrease. This situation can be improved by using more robust nonlinear least square fitting algorithms, such as the Levenberg-Marquardt method. We will discuss the degeneracy problem in section 2 and then show how the constrained fitting can help in section 3. The application of Levenberg-Marquadt method to LOCO is shown in section 4. A summary is given in section 5.

43 PARTICLE ACCELERATORS↗

Modular Adaptive Packing for Integrally Cooled Absorbers

Process intensification is one cornerstone in ION Clean Energy’s (ION) efforts to lowering CO2 capture cost. ION has modeled, designed, and fabricated an innovative gas-liquid contactor known as Modular Adaptive Packing (MAP). During two successful SBIR Phase I and II projects entitled: “Rapid Design and Testing of Novel Gas-Liquid Contacting Devices for Post-Combustion CO2 Capture via 3D-printing”, ION developed and proved this new technology at bench scale. MAP, a 3D-printed lattice-structured packing, combines the absorber gas/liquid contactor with an innovative in-situ heat-exchanger. Thanks to the capabilities of 3D-printing, the lattice structure of MAP contains hollow channels through which coolant water can be pumped to remove the heat of reaction from CO2 absorption. ION refers to this novel method of heat exchange as intracooling. After 25.4 cm (10 in) diameter MAP modules were fabricated, ION built and tested a packing characterization rig at its pilot facility in Boulder, Colorado, U.S.A. To provide baseline results for the characterization rig, ION tested Sulzer’s Mellapak™ 250Y (MP250Y) as a standard structured packing. ION’s MAP was then compared directly to the baseline MP250Y packing to evaluate key indicators including pressure drop, liquid hold-up, and effective area. MAP has a higher pressure drop than MP250Y at the same gas velocities in addition to greater liquid holdup. However, ION found that MAP displays a higher wetting coverage of 93% compared to 65% for MP250Y and reduces shearing forces that result in undesirable droplet formation. Using Optimized Gas Treating’s (OGT) rate-based simulation software ProTreat®, a conceptual evaluation of MAP was modeled for a CO2 absorber using 30 wt% MEA solvent over a range of lean loadings at 90% CO2 capture from a coal-fired power plant. ION modeled a 25-meter column absorber for both the standard MP250Y packing and a hybrid column. The hybrid absorber contained 10 m of MP250Y packing at the top and bottom with the middle 5 meters comprised of MAP. Compared to a traditional intercooled absorber, MAP can remove 22% more heat and increase overall MEA carrying capacity by 4% without increasing overall pressure drop.

20 FOSSIL-FUELED POWER PLANTS↗