Austenite and precipitation in secondary-hardening ultra-high-strength stainless steel

Highlights: • Austenite and precipitation in Ferrium S53 steel were analyzed. • Austenite decreased to less than 5% after cryogenic treatment and tempering. • M{sub 2}C carbide could segregate inside martensite lath or in the larger parallel microstructure. - Abstract: Ferrium S53 is a new secondary-hardening ultra-high-strength stainless steel, with more Cr than other Co-Ni ultra-high-strength steels. Austenite has a great effect on the fracture toughness of this metal, and the carbides that are precipitated are the main strengthening phase of Ferrium S53 steel; in this study, its microstructural changes during heat treatment were observed and analyzed by X-ray diffraction (XRD), Optical microscope (OM), SEM, and transmission electron microscopy (TEM). About 40.85% retained austenite in the quenched sample is decreased to less than 5% after cryogenic treatment and tempering. In the final sample, block austenite is retained austenite, and film austenite around 5 nm in width is reverted austenite. Inside the martensite lath, parallel twin-like structures are actually segregated M{sub 2}C precipitates, and most of them are smaller than 20 nm. These precipitates can be aggregated into a several-micron-long parallel zonal microstructure.

36 MATERIALS SCIENCE↗

X-Ray Absorption near Edge Structure Spectroscopic Study of Hayabusa Category 3 Carbonaceous Particles

Analyses with a scanning transmission x-ray microscope (STXM) using x-ray absorption near edge structure (XANES) spectroscopy were applied for the molecular characterization of two kinds of carbonaceous particles of unknown origin, termed category 3, which were collected from the Hayabusa spacecraft sample catcher. Carbon-XANES spectra of the category 3 particles displayed typical spectral patterns of heterogeneous organic macromolecules; peaks corresponding to aromatic/olefinic carbon, heterocyclic nitrogen and/or nitrile, and carboxyl carbon were all detected. Nitrogen-XANES spectra of the particles showed the presence of N-functional groups such as imine, nitrile, aromatic nitrogen, amide, pyrrole, and amine. An oxygen-XANES spectrum of one of the particles showed a ketone group. Differences in carbon- and nitrogen-XANES spectra of the category 3 particles before and after transmission electron microscopic (TEM) observations were observed, which demonstrates that the carbonaceous materials are electron beam sensitive. Calcium-XANES spectroscopy and elemental contrast mapping identified a calcium carbonate grain from one of the category 3 particles. No fluorine-containing molecular species were detected in fluorine-XANES spectra of the particles. The organic macromolecular features of the category 3 particles were distinct from commercial and/or biological ‘fresh (non-degraded)’ polymers, but the category 3 molecular features could possibly reflect degradation of contaminant polymer materials or polymer materials used on the Hayabusa spacecraft. However, an extraterrestrial origin for these materials cannot currently be ruled out.

Asteroides↗

Size control of highly ordered HfO2 nanotube arrays and a possible growth mechanism

Highly ordered HfO{sub 2} nanotube arrays were prepared through an electrochemical anodization in the presence of NH{sub 4}F and ethylene glycol. The voltage-dependent pore size, wall thickness and porosity were studied using scanning electron microscopy and a wall thickness to pore size ratio was proposed on the basis of the results to serve as a boundary condition additional to the 10% porosity rule introduced by the Gosele group. The average distributions of the tube sizes and wall thicknesses of the nanotubes prepared at 20 V were determined from the small-angle x-ray scattering data using a simple polydisperse core-shell cylinder model fit. Temperature-dependent x-ray diffraction measurements show that the as-grown amorphous nanotube arrays can be converted into crystalline nanotube arrays at a temperature above 500 C. Transmission electron microscopy study of the dimple layer under the as-grown nanotube arrays reveals the presence of a layer of ordered HfO{sub 2} nanocrystals. Further microscopic investigation of the nanotube root region indicates that the nanotubes develop from bulbs produced during anodization. A possible gas bubble initiated growth mechanism based on these observations was proposed.

36 MATERIALS SCIENCE↗

In-situ TEM Holder for Ultrafast, Multimodal Imaging

This project developed a prototype in-situ specimen holder product to transmission electron microscope (TEM) users that drastically expand the usability of TEM by combining nanoscale laser excitation and optical signal collection. A commercial prototype has been constructed and a few nanoscale materials characterization experiments have been performed to validate its performance and demonstrate its utility in real scientific studies, for example, in-situ characterization and mapping of defects in the synthesis of nanostructures.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

In Situ Microscopy and Spectroscopy Applied to Surfaces at Work

Here, the present review discusses the current state of the art microscopic and spectroscopic characterization techniques available to study surfaces and interfaces under working conditions. Microscopic techniques such as environmental transmission electron microscopy and in situ transmission electron microscopy are first discussed showing their applications in the field of nanomaterials and catalysis. Next sum frequency generation vibrational spectroscopy is discussed, giving probing examples of surface studies in gaseous conditions. Synchrotron based X-ray techniques are also examined with a specific focus on ambient pressure X-ray photoelectron and absorption techniques such as near and extended X-ray absorption fine structure. Each of the techniques is evaluated, whilst the pros and cons are discussed in term of surface sensitivity, spatial resolution and/or time resolution. The second part of the articles is articulated around the future of in situ characterization, giving examples of the probable development of the discussed techniques as well as an introduction of emerging tools such as scanning transmission X-ray microscopy, ptychography, and X-ray photon correlation spectroscopy.

36 MATERIALS SCIENCE↗

Electron Beam Irradiated Intercalated CNT Yarns For Aerospace Applications

Multi-walled CNT yarns have been experimentally and commercially created to yield lightweight, high conductivity fibers with good tensile properties for application as electrical wiring and multifunctional tendons. Multifunctional tendons are needed as the cable structures in tensegrity robots for use in planetary exploration. These lightweight robust tendons can provide mechanical strength for movement of the robot in addition to power distribution and data transmission. In aerospace vehicles, such as Orion, electrical wiring and harnessing mass can approach half of the avionics mass. Use of CNT yarns as electrical power and data cables could reduce mass of the wiring by thirty to seventy percent. These fibers have been intercalated with mixed halogens to increase their specific electrical conductivity to that near copper. This conductivity, combined with the superior strength and fatigue resistance makes it an attractive alternative to copper for wiring and multifunctional tendon applications. Electron beam irradiation has been shown to increase mechanical strength in pristine CNT fibers through increased cross-linking. Both pristine and intercalated CNT yarns have been irradiated using a 5-megavolt electron beam for various durations and the conductivities and tensile properties will be discussed. Structural information obtained using a field emission scanning electron microscope, energy dispersive X-ray spectroscopy (EDS), and Raman spectroscopy will correlate microstructural details with bulk properties.

electrical wiring↗

The effect of grain boundary character evolution on the intergranular corrosion behavior of advanced Al-Mg-3wt%Zn alloy with Mg variation

Highlights: • The relationship among GBCD, GBPs, IGC behavior and Mg content in the age hardenable Al-Mg-3.0wt%Zn alloy is established. • None of grain boundaries are found to be immune to the GBPs. • GBPs along low angle grain boundaries are more discontinuous than high angle grain boundaries. • The IGC mechanism of Al-Mg-3.0wt%Zn alloy is clarified. • A new method for the statistical analysis of the continuity of GBPs is used in this paper. The characteristics of grain boundary and grain boundary precipitates of Al-Mg-3wt%Zn alloy with different Mg contents were systematically investigated. Observation by optical microscopy, transmission electron microscopy, scanning transmission electron microscopy and energy-dispersive X-ray spectroscopy show that the morphology and composition of the grain boundary precipitates change little with the variation in the Mg content. Based on the statistical analysis of the spacings between two adjacent grain boundary precipitates, we find that the decrease in the Mg content reduces the continuity of the grain boundary precipitates. Comparing this result with the electron backscattered diffraction analysis, it can be concluded that the continuity of grain boundary precipitates is affected by the proportion of low angle grain boundaries. The observations of grain boundary precipitates at both low angle grain boundaries and high angle grain boundaries using transmission electron microscopy indicate that low angle grain boundaries have more discontinuous grain boundary precipitates. Combining these results with the results of the intergranular corrosion test, the microscopic features of this corrosion behavior and corrosion mechanism are revealed.

36 MATERIALS SCIENCE↗

Mapping causal patterns in crystalline solids

The evolution of the atomic structures of the combinatorial library of Sm-substituted thin film BiFeO 3 along the phase transition boundary from the ferroelectric rhombohedral phase to the non-ferroelectric orthorhombic phase is explored using scanning transmission electron microscopy. Localized properties, including polarization, lattice parameter, and chemical composition, are parameterized from atomic-scale imaging, and their causal relationships are reconstructed using a linear non-Gaussian acyclic model. This approach is further extended to explore the spatial variability of the causal coupling using the sliding window transform method, which revealed that new causal relationships emerged at both the expected locations, such as domain walls and interfaces, and at additional regions forming clusters in the vicinity of the walls or spatially distributed features. While the exact physical origins of these relationships are unclear, they likely represent nanophase-separated regions in the morphotropic phase boundaries. Overall, we posit that an in-depth understanding of complex disordered materials away from thermodynamic equilibrium necessitates understanding not only the generative processes that can lead to observed microscopic states but also the causal links between multiple interacting subsystems.

Causal inference↗

Optimizing supercritical carbon dioxide in the inactivation of bacteria in clinical solid waste by using response surface methodology

Highlights: • Supercritical carbon dioxide sterilization of clinical solid waste. • Inactivation of bacteria in clinical solid waste using supercritical carbon dioxide. • Reduction of the hazardous exposure of clinical solid waste. • Optimization of the supercritical carbon dioxide experimental conditions. - Abstract: Clinical solid waste (CSW) poses a challenge to health care facilities because of the presence of pathogenic microorganisms, leading to concerns in the effective sterilization of the CSW for safe handling and elimination of infectious disease transmission. In the present study, supercritical carbon dioxide (SC-CO{sub 2}) was applied to inactivate gram-positive Staphylococcus aureus, Enterococcus faecalis, Bacillus subtilis, and gram-negative Escherichia coli in CSW. The effects of SC-CO{sub 2} sterilization parameters such as pressure, temperature, and time were investigated and optimized by response surface methodology (RSM). Results showed that the data were adequately fitted into the second-order polynomial model. The linear quadratic terms and interaction between pressure and temperature had significant effects on the inactivation of S. aureus, E. coli, E. faecalis, and B. subtilis in CSW. Optimum conditions for the complete inactivation of bacteria within the experimental range of the studied variables were 20 MPa, 60 °C, and 60 min. The SC-CO{sub 2}-treated bacterial cells, observed under a scanning electron microscope, showed morphological changes, including cell breakage and dislodged cell walls, which could have caused the inactivation. This espouses the inference that SC-CO{sub 2} exerts strong inactivating effects on the bacteria present in CSW, and has the potential to be used in CSW management for the safe handling and recycling-reuse of CSW materials.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nature and evolution of incommensurate charge order in manganites visualized with cryogenic scanning transmission electron microscopy

Incommensurate charge order in hole-doped oxides is intertwined with exotic phenomena such as colossal magnetoresistance, high-temperature superconductivity, and electronic nematicity. Here, we map, at atomic resolution, the nature of incommensurate charge–lattice order in a manganite using scanning transmission electron microscopy at room temperature and cryogenic temperature (~93 K). In diffraction, the ordering wave vector changes upon cooling, a behavior typically associated with incommensurate order. However, using real space measurements, we discover that the ordered state forms lattice-locked regions over a few wavelengths interspersed with phase defects and changing periodicity. The cations undergo picometer-scale (~6 pm to 11 pm) transverse displacements, suggesting that charge–lattice coupling is strong. We further unearth phase inhomogeneity in the periodic lattice displacements at room temperature, and emergent phase coherence at 93 K. Such local phase variations govern the long-range correlations of the charge-ordered state and locally change the periodicity of the modulations, resulting in wave vector shifts in reciprocal space. These atomically resolved observations underscore the importance of lattice coupling and phase inhomogeneity, and provide a microscopic explanation for putative “incommensurate” order in hole-doped oxides.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Compact single-shot soft X-ray photon spectrometer for free-electron laser diagnostics

The photon spectrum from free-electron laser (FEL) light sources offers valuable information in time-resolved experiments and machine optimization in the spectral and temporal domains. We have developed a compact single-shot photon spectrometer to diagnose soft X-ray spectra. The spectrometer consists of an array of off-axis Fresnel zone plates (FZP) that act as transmission-imaging gratings, a Ce:YAG scintillator, and a microscope objective to image the scintillation target onto a two-dimensional imaging detector. This spectrometer operates in segmented energy ranges which covers tens of electronvolts for each absorption edge associated with several atomic constituents: carbon, nitrogen, oxygen, and neon. The spectrometer’s performance is demonstrated at a repetition rate of 120 Hz, but our detection scheme can be easily extended to 200 kHz spectral collection by employing a fast complementary metal oxide semiconductor (CMOS) line-scan camera to detect the light from the scintillator. This compact photon spectrometer provides an opportunity for monitoring the spectrum downstream of an endstation in a limited space environment with sub-electronvolt energy resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MICRO/NANO-STRUCTURAL EXAMINATION AND FISSION PRODUCT IDENTIFICATION IN NEUTRON IRRADIATED AGR-1 TRISO FUEL

Advanced microscopic and microanalysis techniques were developed and applied to study irradiation effects and fission product behavior in selected low-enriched uranium oxide/uranium carbide TRISO-coated particles from fuel compacts in six capsules irradiated to burnups of 11.2 to 19.6% FIMA. Although no TRISO coating failures were detected during the irradiation, the fraction of Ag-110m retained in individual particles often varied considerably within a single compact and at the capsule level. At the capsule level Ag-110m release fractions ranged from 1.2 to 38% and within a single compact, silver release from individual particles often spanned a range that extended from 100% retention to nearly 100% release. In this paper, selected irradiated particles from Baseline, Variant 1 and Variant 3 type fueled TRISO coated particles were examined using Scanning Electron Microscopy, Atom Probe Tomography; Electron Energy Loss Spectroscopy; Precession Electron Diffraction, Transmission Electron Microscopy, Scanning Transmission Electron Microscopy (STEM), High Resolution Electron Microscopy (HRTEM) examinations and Electron Probe Micro-Analyzer. Particle selection in this study allowed for comparison of the fission product distribution with Ag retention, fuel type and irradiation level. Nano sized Ag-containing features were predominantly identified in SiC grain boundaries and/or triple points in contrast with only two sitings of Ag inside a SiC grain in two different compacts (Baseline and Variant 3 fueled compacts). STEM and HRTEM analysis showed evidence of Ag and Pd co-existence in some cases and it was found that fission product precipitates can consist of multiple or single phases. STEM analysis also showed differences in precipitate compositions between Baseline and Variant 3 fuels. A higher density of fission product precipitate clusters were identified in the SiC layer in particles from the Variant 3 compact compared with the Variant 1 compact. Trend analysis shows precipitates were randomly distributed along the perimeter of the IPyC-SiC interlayer but only weakly associated with kernel protrusion and buffer fractures. There has been no evidence that the general release of silver is related to cracks or significant degradation of the microstructure. The results presented in this paper provide new insights to Ag transport mechanism(s) in intact SiC layer of TRISO coated particles.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Spectroscopic and Microscopic Evidence of Biomediated HgS Species Formation from Hg(II)–Cysteine Complexes: Implications for Hg(II) Bioavailability

In this work we investigated the chemistry of Hg(II) during exposure of exponentially growing bacteria ( Escherichia coli , Bacillus subtilis , and Geobacter sulfurreducens ) to 50 nM, 500 nM, and 5 μM total Hg(II) with and without added cysteine. With X-ray absorption spectroscopy, we provide direct evidence of the formation of cell-associated HgS for all tested bacteria. The addition of cysteine (100–1000 μM) promotes HgS formation (>70% of total cell-associated Hg(II)) as a result of the biodegradation of added cysteine to sulfide. Cell-associated HgS species are also detected when cysteine is not added as a sulfide source. Two phases of HgS, cinnabar (α-HgS) and metacinnabar (β-HgS), form depending on the total concentration of Hg(II) and sulfide in the exposure medium. However, α-HgS exclusively forms in assays that contain an excess of cysteine. Scanning transmission electron microscopy images reveal that nanoparticulate HgS (s) is primarily located at the cell surface/extracellular matrix of Gram-negative E. coli and G. sulfurreducens and in the cytoplasm/cell membrane of Gram-positive B. subtilis . Intracellular Hg(II) was detected even when the predominant cell-associated species was HgS. This study shows that HgS species can form from exogenous thiol-containing ligands and endogenous sulfide in Hg(II) biouptake assays under nondissimilatory sulfate reducing conditions, providing new considerations for the interpretation of Hg(II) biouptake results.

54 ENVIRONMENTAL SCIENCES↗

The effects of carbon coating on nanoripples induced by focused ion beam

The morphology and topography of self-assembled nanoripple structures on LaAlO{sub 3} (100) surface with and without carbon coating were characterized using focused ion beam (FIB)/scanning electron microscope, as well as ex situ atomic force microscopy and transmission electron microscopy. When the surface was not covered by carbon coating and had low roughness, well-ordered and highly uniform nanoripples self-assembled on the surface bombarded by FIB. In contrast, disordered nanoripples formed after carbon coating. The deposited carbon significantly influences the morphology of surface nanoripples due to its effect on the surface roughness that affect the dynamic competition between the roughening and smoothing processes. This discovery suggests a means for fabricating well-ordered and highly uniform nanoripples for nanoscale devices application.

36 MATERIALS SCIENCE↗

Preparing Lamellae from Vitreous Biological Samples using a Dual-Beam Scanning Electron Microscope for Cryo-Electron Tomography

Presented here is a protocol for preparing cryo-lamellae from plunge-frozen grids of Plasmodium falciparum-infected human erythrocytes, which could easily be adapted for other biological samples. The basic principles for preparing samples, milling, and viewing lamellae are common to all instruments and the protocol can be followed as a general guide to on-grid cryo-lamella preparation for cryo-electron microscopy (cryoEM) and cryo-electron tomography (cryoET). Electron microscopy grids supporting the cells are plunge-frozen into liquid nitrogen-cooled liquid ethane using a manual or automated plunge freezer, then screened on a light microscope equipped with a cryo-stage. Frozen grids are transferred into a cryo-scanning electron microscope equipped with a focused ion beam (cryoFIB-SEM). Grids are routinely sputter coated prior to milling, which aids dispersal of charge build-up during milling. Alternatively, an e-beam rotary coater can be used to apply a layer of carbon-platinum to the grids, the exact thickness of which can be more precisely controlled. Once inside the cryoFIB-SEM an additional coating of an organoplatinum compound is applied to the surface of the grid via a gas injection system (GIS). This layer protects the front edge of the lamella as it is milled, the integrity of which is critical for achieving uniformly thin lamellae. Regions of interest are identified via SEM and milling is carried out in a step-wise fashion, reducing the current of the ion beam as the lamella reaches electron transparency, in order to avoid excessive heat generation. A grid with multiple lamellae is then transferred to a transmission electron microscope (TEM) under cryogenic conditions for tilt-series acquisition. A robust and contamination-free workflow for lamella preparation is an essential step for downstream techniques, including cellular cryoEM, cryoET, and sub-tomogram averaging. Development of these techniques, especially for lift-out and milling of high-pressure frozen samples, is of high-priority in the field.

59 BASIC BIOLOGICAL SCIENCES↗

Development of a Scanning Microscale Fast Neutron Irradiation Platform for Examining the Correlation Between Local Neutron Damage and Graphite Microstructure

The fast particle radiation damage effect of graphite, a main material in current and future nuclear reactors, has significant influence on the utilization of this material in fission and fusion plants. Atoms on graphite crystals can be easily replaced or dislocated by fast protons and result in interstitials and vacancies. The currently accepted model indicates that after most of the interstitials recombine with vacancies, surviving interstitials form clusters and furthermore gather to create loops with each other between layers. Meanwhile, surviving vacancies and interstitials form dislocation loops on the layers. The growth of these inserted layers cause the dimensional increase, i.e. swelling, of graphite. Interstitial and vacancy dislocation loops have been reported and they can easily been observed by electron microscope. However, observation of the intermediate atom clusters becomes is paramount in helping prove this model. We utilize fast protons generated from the University of Missouri Research Reactor (MURR) cyclotron to irradiate highly- oriented pyrolytic graphite (HOPG) as target for this research. Post-irradiation examination (PIE) of dosed targets with high-resolution transmission electron microscopy (HRTEM) has permit observation and analysis of clusters and dislocation loops to support the proposed theory. Another part of the research is to validate M.I. Heggie’s Ruck and Tuck model, which introduced graphite layers may fold under fast particle irradiation. Again, we employed microscopy to image irradiated specimens to determine how the extent of Ruck and Tuck by calculating the number of folds as a function of dose. Our most significant accomplishment is the invention of a novel class of high-intensity pure beta-emitters for long-term lightweight batteries. We have filed four invention disclosure records based on the research conducted in this project. These batteries are lightweight because they consist of carbon and tritium and can be fabricated to conform to many geometric shapes. In addition, we have published eight peer-reviewed American Nuclear Society (ANS) transactions, and presented our findings at ANS National Meetings, and several universities.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Nanostructure-Driven Ion Transport in PCBM-Based Polymer Electrolytes

Nanostructure-Driven Ion Transport in PCBM-Based Polymer ElectrolytesChe-Nan Sun1, Thomas A. Zawodzinski1,2, Fei Ren3, Jong Kahk Keum1 and Jihua Chen1, (1)Oak Ridge National Laboratory, (2)The University of Tennessee, (3)Temple University Polyethylene oxide or PEO is an extensively-examined candidate for solid polymer electrolyte materials of lithium ion batteries, and its composite electrolytes has promising ion conductivities.[1-3] Oxide nanoparticles with sizes of 5-10 nm are often introduced into these polymer-based composite electrolytes in order to suppress their room-temperature crystallite formation.1-9 The size, geometry and surface functionality of the added particles were known to largely affect the structure and performance of the blended electrolytes.5,10 In this study, we examined a functionalized-fullerene-based composite electrolytes, providing details in their self-assembled nanostructures, modulus, hardness, as well as temperature-dependent ion-conducting behaviors. To the best of our knowledge, no fullerene-based, lithium conducting, composite electrolyte has been reported previously. Herein we used a bench-mark fullerene derivative, phenyl-C61-butyric acid methyl ester (PCBM) as a model fullerene compound and performed impedance spectroscopy, equivalent circuit modeling, nanoscale elemental mapping (in transmission electron microscope), wide-angle X-ray diffraction, as well as nanoindentation to shed light on a 6-fold enhancement in low temperature (less than 50oC) ion conductivity of PEO - lithium bis(trifluoromethanesulfonyl) imide (LiTFSI)-PCBM electrolytes, along with the underlying changes in nanomorphology , mechanical properties, and crystal structures. Based on a previous density functional theory (DFT) calculation, 11 the interaction energies Ei among PEO polymers is estimated to be 2.58 kcal mol-1 per monomer, the Ei between PCBM and PEO is 3.50 kcal mol-1 per monomer (PCBM is taken as 1 repeat unit), and the Ei among PCBMs themselves is 6.01 kcal mol-1 per monomer. This explains that at very low PCBM weight percentage, without sufficient PCBM-PCBM contacts, it is more energetically favorable for fullerenes to disperse into PEO matrix. However, with higher PCBM concentration, the fullerenes will efficiently pack with each other into domains with gradually increased dimensions. Quantification of PCBM domains is performed by line scan analysis of energy filtered TEM (EFTEM) images. Upon the addition of PCBM, the average domain sizes gradually increase from 3.4±1 nm ( 0% PCBM), to 4.6±1 nm (10% PCBM) and 4.9±2 nm (20% PCBM), and finally to 7.5±5 nm (40% PCBM ). (A precise determination of PCBM domain dimension is not possible when the domain size is less than 3 nm, due to the lack of EFTEM contrast in these samples). We attribute the observed ion conductivity improvement to those nanomorphological variation in PCBM-PEO-LiTFSi systems.

77 NANOSCIENCE AND NANOTECHNOLOGY↗