Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

A study on the structural and mechanical properties of nanocrystalline CuS thin films grown by chemical bath deposition technique

We report a chemical route for the deposition of nanocrystalline thin films of CuS, using aqueous solutions of Cu(CH{sub 3}COO){sub 2}, SC(NH{sub 2}){sub 2} and N(CH{sub 2}CH{sub 2}OH){sub 3} [triethanolamine, i.e. TEA] in proper concentrations and ratios. The films were structurally characterized using X-ray diffraction technique (XRD), field emission scanning electron microscopy (FESEM) and optical analysis [both photo luminescence (PL) and ultraviolet-visible (UV-vis)]. Optical studies showed a large blue shift in the band gap energy of the films due to quantum confinement effect exerted by the nanocrystals. From both XRD and FESEM analyses, formation of CuS nanocrystals with sizes within 10-15 nm was evident. A study on the mechanical properties was carried out using nanoindentation and nanoscratch techniques, which showed good mechanical stability and high adherence of the films with the bottom substrate. Such study on the mechanical properties of the CuS thin films is being reported here for the first time. Current-voltage (I-V) measurements were also carried out for the films, which showed p-type conductivity.

36 MATERIALS SCIENCE↗

Electrochemical behavior of potentiodynamically deposited cobalt oxyhydroxide (CoOOH) thin films for supercapacitor application

Graphical abstract: Scanning electron micrograph (SEM) images of cobalt oxyhydroxide thin film at (a) 2000 Multiplication-Sign and (b) 10,000 Multiplication-Sign magnifications. Highlights: Black-Right-Pointing-Pointer Simple method for the synthesis of CoOOH thin films. Black-Right-Pointing-Pointer Supercapacitor with maximum specific capacitance of 449 F g{sup -1}. Black-Right-Pointing-Pointer High charge/discharge efficiency. -- Abstract: In the present study, we report, for the first time, the synthesis of cobalt oxyhydroxide thin films on inexpensive stainless steel substrate using potentiodynamic electrodeposition method. These films were characterized by X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FT-IR) and scanning electron microscopy (SEM) techniques. The orthorhombic crystal structure was revealed by the X-ray diffraction study. The FT-IR spectrum confirmed the formation of cobalt oxyhydroxide. The SEM studies showed the nanoflakes-like morphology with an average thickness of 100 nm. The cyclic voltammetry study of the cobalt oxyhydroxide films in 1 M KOH showed maximum specific capacitance of 449 F g{sup -1} at scan rate of 5 mV s{sup -1}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantification of surface displacements and electromechanical phenomena via dynamic atomic force microscopy

Detection of dynamic surface displacements associated with local changes in material strain provides access to a number of phenomena and material properties. Contact resonance-enhanced methods of atomic force microscopy (AFM) have been shown capable of detecting ~1–3 pm-level surface displacements, an approach used in techniques such as piezoresponse force microscopy, atomic force acoustic microscopy, and ultrasonic force microscopy. Here, based on an analytical model of AFM cantilever vibrations, we demonstrate a guideline to quantify surface displacements with high accuracy by taking into account the cantilever shape at the first resonant contact mode, depending on the tip–sample contact stiffness. The approach has been experimentally verified and further developed for piezoresponse force microscopy (PFM) using well-defined ferroelectric materials. These results open up a way to accurate and precise measurements of surface displacement as well as piezoelectric constants at the pm-scale with nanometer spatial resolution and will allow avoiding erroneous data interpretations and measurement artifacts. Furthermore, this analysis is directly applicable to all cantilever-resonance-based scanning probe microscopy (SPM) techniques.

36 MATERIALS SCIENCE↗

Transmission Kikuchi diffraction and transmission electron forescatter imaging of electropolished and FIB manufactured TEM specimens

We present a study of the efficiency of the utility of scanning electron microscope (SEM)-based transmission methods for characterizing grain structure in thinned bulk metals. Foils of type 316 stainless steel were prepared by two methods commonly used for transmission electron microscopy — double-jet electropolishing and focused ion beam milling. A customized holder allowed positioning of the foils in a configuration appropriate for both transmission electron forward scatter diffraction, and for transmission imaging by the use of a forescatter detector with two diodes. We found that both crystallographic orientation maps and dark-field transmitted images could be obtained for specimens prepared by either method. However, for both methods, preparation-induced artifacts may affect the quality or accuracy of transmission SEM data, especially those acquired by the use of transmission Kikuchi diffraction. Generally, the quality of orientation data was better for specimens prepared by electropolishing, due to the absence of ion-induced damage. - Highlights: • The transmission imaging and diffraction techniques are emerging in scanning electron microscopy (SEM) as promising new field of materials characterization. • The manuscript titled: “Transmission Kikuchi Diffraction and Transmission Electron Forescatter Imaging of Electropolished and FIB Manufactured TEM Specimens” documents how different specimen thinning procedures can effect efficiency of transmission Kikuchi diffraction and transmission electron forescatter imaging. • The abilities to make precision crystallographic orientation maps and dark-field images in transmission was studied on electropolished versus focus ion beam manufactured TEM specimens. • Depending on the need, electropolished and focused ion beam technique may produce suitable specimens for transmission imaging and diffraction in SEM.

36 MATERIALS SCIENCE↗

Determining the Molecular Growth Mechanisms of Tetragonal Lysozyme Crystals

Studies of the growth of tetragonal lysozyme crystals employing atomic force microscopy (AFM) have shown the advantages of this technique in investigating the growth mechanisms of protein crystals [1]. The resolution of these studies was in the micron range, which revealed surface features such as the occurrence of dislocations and 2D nucleation islands, similar to those found in inorganic systems. They clearly showed that the crystals grew by these surface growth mechanisms. However, the studies also revealed some surprising features, such as bimolecular growth step heights and pronounced growth anisotropies on the (110) face, which could not be explained. In previous studies we employed Periodic Bond Chain (PBC) theory to tetragonal lysozyme crystal growth and found that the crystals were constructed by strongly bonded molecular chains forming helices about the 43 axes [2,3]. The helices were connected to each other with weaker bonds. The growth process was shown to proceed by the formation of these 43 helices, resulting in bimolecular growth steps on the (110) face. It was also shown to explain many other observations on tetragonal lysozyme crystal growth. Although PBC analysis is not a new technique [4], it has not been widely used as the mechanisms predicted from it could not be experimentally verified. In this study the growth process of these crystals was investigated, particularly for the (110) face, employing some newly developed high resolution AFM techniques. These techniques allowed individual lysozyme molecules on the crystal faces to be resolved and predictions from PBC analyses to be tested. The analyses had shown that of the two possible packing arrangements on (110) faces, only one would actually occur. Employing the first of the newly developed techniques, these faces were scanned by high resolution AFM. The resulting images were then compared with the theoretically constructed images for the two possible packing arrangements on the (110) face. The theoretical images were constructed by convolution of the crystal surface shape obtained from crystallographic data with the AFM tip shape. The comparison confirmed the prediction that the molecular packing arrangement of these faces corresponded to that for complete 43 helices. The second AFM technique that was developed was used to follow the growth process by measuring the dimensions of individual growth units on the (110) face. Linescans across a growth step, performed near the saturation limit of the crystals, allowed the growth unit dimensions to be measured. These measurements showed that growth on the (110) face proceeded by the formation of new 43 helices from the addition of at least tetramer units in the [110] direction. In the [001] direction growth proceeded by the addition of various aggregate units corresponding to the 4(sub 3) helices.

Li, Huayu↗

Low-Voltage Scanning Electron Microscopy and Energy-Dispersive X-Ray Microanalysis of the Interface of Multilayer Polymer Composite

The morphology of the layer of polyelectrolyte complex, which is formed in the composite based on chitosan and sulfoethyl cellulose during the contact of a solution of one of them with a gel film of the other one, has been investigated by the low-voltage (≤3 kV) scanning electron microscopy. A technique for eliminating the effects related to charge accumulation on the dielectric film surface is proposed.

36 MATERIALS SCIENCE↗

Direct imaging of Cl- and Cu-induced short-circuit efficiency changes in CdTe solar cells

To achieve high-efficiency polycrystalline CdTe-based thin-film solar cells, the CdTe absorbers must go through a post-deposition CdCl 2 heat treatment followed by a Cu diffusion step. To better understand the roles of each treatment with regard to improving grains, grain boundaries, and interfaces, CdTe solar cells with and without Cu diffusion and CdCl 2 heat treatments are investigated using cross-sectional electron beam induced current, electron backscatter diffraction, and scanning transmission electron microscope techniques. The evolution of the cross-sectional carrier collection profile due to these treatments that cause an increase in short-circuit current and higher open-circuit voltage are identified. Additionally, an increased carrier collection in grain boundaries after either/both of these treatments is revealed. The increased current at the grain boundaries is shown to be due to the presence of a space charge region with an intrinsic carrier collection profile width of ≈350 nm. Scanning transmission electron microscope electron-energy loss spectroscopy shows a decreased Te and increased Cl concentration in grain boundaries after treatment, which causes the inversion. Furthermore, each treatment improves the overall carrier collection efficiency of the cell separately, and, therefore, the benefits realized by each treatment are shown to be independent of each other.

14 SOLAR ENERGY↗

Relative plan robustness of step-and-shoot vs rotational intensity–modulated radiotherapy on repeat computed tomographic simulation for weight loss in head and neck cancer

Introduction: Interfractional anatomical alterations may have a differential effect on the dose delivered by step-and-shoot intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT). The increased degrees of freedom afforded by rotational delivery may increase plan robustness (measured by change in target volume coverage and doses to organs at risk [OARs]). However, this has not been evaluated for head and neck cancer. Materials and methods: A total of 10 patients who required repeat computed tomography (CT) simulation and replanning during head and neck IMRT were included. Step-and-shoot IMRT and VMAT plans were generated from the original planning scan. The initial and second CT simulation scans were fused and targets/OAR contours transferred, reviewed, and modified. The plans were applied to the second CT scan and doses recalculated without repeat optimization. Differences between step-and-shoot IMRT and VMAT for change in target volume coverage and doses to OARs between first and second CT scans were compared by Wilcoxon signed rank test. Results: There were clinically relevant dosimetric changes between the first and the second CT scans for both the techniques (reduction in mean D{sub 95%} for PTV2 and PTV3, D{sub min} for CTV2 and CTV3, and increased mean doses to the parotid glands). However, there were no significant differences between step-and-shoot IMRT and VMAT for change in any target coverage parameter (including D{sub 95%} for PTV2 and PTV3 and D{sub min} for CTV2 and CTV3) or dose to any OARs (including parotid glands) between the first and the second CT scans. Conclusions: For patients with head and neck cancer who required replanning mainly due to weight loss, there were no significant differences in plan robustness between step-and-shoot IMRT and VMAT. This information is useful with increased clinical adoption of VMAT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Mass-transport properties of electrosprayed Pt/C catalyst layers for polymer-electrolyte fuel cells

Mass-transport properties of electrosprayed catalyst-layers based on Pt/C and ionomer (Nafion) are investigated with hydrogen limiting-current technique, water-vapor-uptake, scanning transmission microscopy (STEM), single-cell testing, and impedance spectroscopy. The hydrogen limiting-current technique provides the transport resistance of the layers ( R CL m t ), which demonstrates to be lower in electrosprayed layers compared with conventional layers, especially at very low platinum loadings (0.025 mg Pt ·cm -2 ) and low cell temperature, denoting superior mass-transport properties. Images of the distribution of Pt, F, and C elements reveal the ionomer preferentially interacting with the Pt nanoparticles. Water-vapor-uptake experiments show larger vapor absorption for electrosprayed than conventional catalyst layers. Such large water-vapor uptake capability is combined with superhydrophobicity, ie. very low interaction with water in liquid phase (wettability). Both apparently contradictory properties result from a particular configuration of the amphiphilic ionomer in the electrosprayed layers, and provide ideal conditions for high mass transport and ionic conductivity in a catalyst layer. Electrosprayed layers as cathode catalyst layers reflect peak response at a loading of 0.17 mg Pt ·cm -2 (18 μm layer thickness when using Pt/C 20 wt% catalyst) where they provide minimal mass-transport and polarization resistances.

08 HYDROGEN↗

A scanning laser velocimeter for turbulence research

Turbulent and unsteady separated flows occur on most practical flight vehicles, but are not yet sufficiently understood for designs to provide safe margins of performance without recourse to extensive experiment and computation. In date, reliable experimental data for even basic flows is severely limited and does not yet provide a satisfactory data base with which to assess current design and calculation methods. Although the laser velocimeter (LV) has become a proven, nonintrusive instrument for the measurement of local mean velocities and turbulence properties, measurements have been of a mean, statistical nature derived from averages accumulated independently at different positions in the flow. Thus, the measurements do not give an instantaneous dynamic, picture of the flow-field structures. Accordingly, a new technique for rapid LV scans of turbulent flow fields was proposed. The potential of this new instrument for fundamental fluid mechanical measurements of turbulent flows has been demonstrated. The results clearly show that significant unsteady flow features are hidden by conventional measurements and that the scanning laser velocimeter should prove an invauable tool in future studies of the structure of turbulent flows.

Duen, F. K.↗

Identification and characterization of extraterrestrial non-chondritic interplanetary dust

Interplanetary dust particles (IDPs) are among the most pristine and primitive extraterrestrial materials available for direct study. Most of the stratospheric particles selected for study from the JSC Curatorial Collection were chondritic in composition (major element abundances within a factor of two of chondritic meteorites) because this composition virtually ensures that the particle is from an extraterrestrial source. It is likely that some of the most interesting classes of IDP's have not been recognized simply because they are not chondritic or do not fit established criteria for extraterrestrial origin. Indeed, mass spectroscopy data from the Giotto Flyby of comet Halley indicate that a substantial fraction of the dust is in the submicron size range and that a majority of these particles contain C, H, O, and/or N as major elements. The preponderance of CHON particles in the coma of Halley implies that similar particles may exist in the JSC stratospheric dust collection. However, the JSC collection also contains a variety of stratospheric contaminants from terrestrial sources which have these same characteristics. Because established criteria for extraterrestrial origin may not apply to such particles in individual cases, and integrated approach is required in which a variety of analysis techniques are applied to the same particle. Non-chondritic IDP's, like their chondritic counterparts, can be used to elucidate pre- and early solar system processes and conditions. The study of non-chondritic IDP's may additionally yield unique information which bears on the nature of cometary bodies and the processing of carbonaceous and other low atomic number materials. A suite of complementary techniques, including Low Voltage Scanning Electron Microscopy (LVSEM), Energy-Dispersive X-ray Microanalysis (EDX), Secondary Ion Mass Spectrometry (SIMS) isotope-ratio imaging and Analytical Electron Microscopy (AEM), were utilized to accomplish the following two objectives: (1) to develop criteria for the unequivocal identification of extraterrestrial non-chondritic IDP's; and (2) to infer IDP parent body, solar nebula, and pre-solar conditions through the study of phases, textures, and components contained within non-chondritic IDP's. The general approach taken is designed to maximize the total information obtained from each particle. Techniques will be applied in order from least destructive to most destructive.

Blake, D. F.↗

Structure of cleaved (001) USb2 single crystal

We have achieved what we believe to be the first atomic resolution STM images for a uranium compound taken at room temperature. The a, b, and c lattice parameters in the images confirm that the USb{sub 2} crystals cleave on the (001) basal plane as expected. The a and b dimensions were equal, with the atoms arranged in a cubic pattern. Our calculations indicate a symmetric cut between Sb planes to be the most favorable cleavage plane and U atoms to be responsible for most of the DOS measured by STM. Some strange features observed in the STM will be discussed in conjunction with ab initio calculations. The purpose of this work is to demonstrate the power of scanning tunneling microscopy (STM) techniques combined with a theoretical underpinning to determine the surface atomic structure and properties of actinide materials, such as the quasi 2-dimensional uranium dipnictide USb{sub 2} single crystal, thereby contributing to the understanding of their surface structural and electronic properties. The members of this interesting UX{sub 2} (X=P, As, Sb, Bi) series of compounds display dual localized and itinerant 5f electron behavior within the same compound due to the hybridization of the 5f orbitals with the conduction band. With the exception of UO{sub 2}, which has to be studied at elevated temperature to generate enough carriers for STM imaging, STM techniques have not been applied successfully to the characterization of the surface atomic structure of any other single crystal actinide compound, to the best of our knowledge. However, STM has been used to a limited extent for the study of some cerium compounds. STM probes electronic properties at the atomic level and can directly provide information about the local density of filled and empty states (LDOS) states simultaneously. A STM topograph provides the local atomic arrangement and spacing of the atoms on the surface, local defect structures (e.g. steps, vacancies, and kink sites) and the presence of contaminants, all of which are averaged over when probed in photoemission studies. The quasi two-dimensional USb{sub 2} has a layered tetragonal structure that is easily cleaved and has been extensively studied by a number of different techniques, such as resistivity, Hall effect measurements, photoemission and angle-resolved photoemission spectroscopy, de Haas-van Alphen, neutron diffraction, nuclear magnetic resonance, and U{sup 238} Mossbauer spectroscopy techniques. Here, we provide local information about the surfaces of this interesting compound, which we find to contain a high density of defects.

36 MATERIALS SCIENCE↗

Determination of surface structure of cleaved (001) USb2 single crystal

We have achieved what we believe to be the first atomic resolution STM images for a uranium compound taken at room temperature. The a, b, and c lattice parameters in the images confirm that the USb{sub 2} crystals cleave on the (001) basal plane as expected. The a and b dimensions were equal, with the atoms arranged in a cubic pattern. Our calculations indicate a symmetric cut between Sb planes to be the most favorable cleavage plane and U atoms to be responsible for most of the DOS measured by STM. Some strange features associated with vacancies were observed in the STM win be discussed in conjunction with ab initio calculations. The purpose of this work is to demonstrate the power of scanning tunneling microscopy (STM) techniques combined with a theoretical underpinning to determine the surface atomic structure and properties of actinide materials, such as the quasi 2-dimensional uranium dipnictide USb{sub 2} single crystal, thereby contributing to the understanding of their surface structural and electronic properties. The members of this interesting UX{sub 2} (X=P, As, Sb, Bi) series of compounds display dual localized and itinerant 5f electron behavior within the same compound due to the hybridization of the 5f orbitals with the conduction band. With the exception of UO{sub 2}, which has to be studied at elevated temperature to generate enough carriers for STM imaging, STM techniques have not been applied successfully to the characterization of the surface atomic structure of any other single crystal actinide compound, to the best of our knowledge. However, STM has been used to a limited extent for the study of some cerium compounds. STM probes electronic properties at the atomic level and can directly provide information about the local density of filled and empty states (LDOS) states simultaneously. A STM topograph provides the local atomic arrangement and spacing of the atoms on the surface, local defect structures (e.g. steps, vacancies, and kink sites), and the presence of contaminants, all of which are averaged over when probed in photoemission studies. The quasi two-dimensional USb{sub 2} has a layered tetragonal structure that is easily cleaved and has been extensively studied by a number of different techniques, such as resistivity, Hall effect measurements, photoemission and angle-resolved photoemission spectroscopy, de Haas-van Alphen, neutron diffraction, nuclear magnetic resonance, and U{sup 238} Mossbauer spectroscopy techniques. Here, we provide local information about the surfaces of this interesting compound, which we find to contain a high density of defects.

36 MATERIALS SCIENCE↗

Neutron sub-micrometre tomography from scattering data

Neutrons are valuable probes for various material samples across many areas of research. Neutron imaging typically has a spatial resolution of larger than 20 µm, whereas neutron scattering is sensitive to smaller features but does not provide a real-space image of the sample. A computed-tomography technique is demonstrated that uses neutron-scattering data to generate an image of a periodic sample with a spatial resolution of ∼300 nm. The achieved resolution is over an order of magnitude smaller than the resolution of other forms of neutron tomography. This method consists of measuring neutron diffraction using a double-crystal diffractometer as a function of sample rotation and then using a phase-retrieval algorithm followed by tomographic reconstruction to generate a map of the sample's scattering-length density. Topological features found in the reconstructions are confirmed with scanning electron micrographs. This technique should be applicable to any sample that generates clear neutron-diffraction patterns, including nanofabricated samples, biological membranes and magnetic materials, such as skyrmion lattices.

nanoscience↗

High accuracy plasma density measurement using hybrid Langmuir probe and microwave interferometer method

High spatial resolution plasma density measurements have been taken as part of an investigation into magnetic nozzle physics at the NASA/MSFC Propulsion Research Center. These measurements utilized a Langmuir triple probe scanned across the measurement chord of either of two stationary rf interferometers. By normalizing the scanned profile to the microwave interferometer line-integrated density measurement for each electrostatic probe measurement, the effect of shot-to-shot variation of the line-integrated density can be removed. In addition, by summing the voltage readings at each radial position in a transverse scan, the line density can be reconstituted, allowing the absolute density to be determined, assuming that the shape of the profile is constant from shot to shot. The spatial and temporal resolutions of this measurement technique depend on the resolutions of the scanned electrostatic probe and the interferometer. The measurement accuracy is 9%-15%, which is on the order of the accuracy of the rf interferometer. The measurement technique was compared directly with both scanning rf interferometer and standard Langmuir probe theory. The hybrid technique compares favorably with the scanning rf interferometer, and appears more accurate than probe theory alone. Additionally, our measurement technique is generally applicable even for nonaxisymmetric plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hurricane Wind Field Measurements with Scanning Airborne Doppler Lidar During CAMEX-3

During the 1998 Convection and Moisture Experiment (CAMEX-3), the first hurricane wind field measurements with Doppler lidar were achieved. Wind fields were mapped within the eye, along the eyewall, in the central dense overcast, and in the marine boundary layer encompassing the inflow region. Spatial coverage was determined primarily by cloud distribution and opacity. Within optically-thin cirrus slant range of 20- 25 km was achieved, whereas no propagation was obtained during penetration of dense cloud. Measurements were obtained with the Multi-center Airborne Coherent Atmospheric Wind Sensor (MACAWS) on the NASA DC-8 research aircraft. MACAWS was developed and operated cooperatively by the atmospheric lidar remote sensing groups of NOAA Environmental Technology Laboratory, NASA Marshall Space Flight Center, and Jet Propulsion Laboratory. A pseudo-dual Doppler technique ("co-planar scanning") is used to map the horizontal component of the wind at several vertical levels. Pulses from the laser are directed out the left side of the aircraft in the desired directions using computer-controlled rotating prisms. Upon exiting the aircraft, the beam is completely eyesafe. Aircraft attitude and speed are taken into account during real-time signal processing, resulting in determination of the ground-relative wind to an accuracy of about 1 m/s magnitude and about 10 deg direction. Beam pointing angle errors are about 0.1 deg, equivalent to about 17 m at 10 km. Horizontal resolution is about 1 km (along-track) for typical signal processor and scanner settings; vertical resolution varies with range. Results from CAMEX-3 suggest that scanning Doppler wind lidar can complement airborne Doppler radar by providing wind field measurements in regions that are devoid of hydrometeors. At present MACAWS observations are being assimilated into experimental forecast models and satellite Doppler wind lidar simulations to evaluate the relative impact.

Rothermel, Jeffry↗

Scanning tunneling thermometer

Various examples are provided related to scanning tunneling thermometers and scanning tunneling microscopy (STM) techniques. In one example, a method includes simultaneously measuring conductance and thermopower of a nanostructure by toggling between: applying a time modulated voltage to a nanostructure disposed on an interconnect structure, the time modulated voltage applied at a probe tip positioned over the nanostructure, while measuring a resulting current at a contact of the interconnect structure; and applying a time modulated temperature signal to the nanostructure at the probe tip, while measuring current through a calibrated thermoresistor in series with the probe tip. In another example, a device includes an interconnect structure with connections to a first reservoir and a second reservoir; and a scanning tunneling probe in contact with a probe reservoir. Electrical measurements are simultaneously obtained for temperature and voltage applied to a nanostructure between the reservoirs.

Chinivaranahalli Shastry, Abhay Shankar↗