Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Local electric field direct writing – Electron-beam lithography and mechanism

Local electric field induced by a focused electron probe in silicate glass thin films is evaluated in this paper by the migration of cations. Extremely strong local electric fields can be obtained by the focused electron probe from a scanning transmission electron microscope. As a result, collective atomic displacements occur. This newly revised mechanism provides an efficient tool to write patterned nanostructures directly, and thus overcome the low efficiency of the conventional electron-beam lithography. Applying this technique to silicate glass thin films, as an example, a grid of rods of nanometer dimension can be efficiently produced by rapidly scanning a focused electron probe. This nanopatterning is achieved through swift phase separation in the sample, without any post-development processes. The controlled phase separation is induced by massive displacements of cations (glass modifiers) within the glass-former network, driven by the strong local electric fields. The electric field is induced by accumulated charge within the electron probed region, which is generated by the excitation of atomic electrons by the incident electron. Throughput is much improved compared to other scanning probe techniques. Finally, the half-pitch spatial resolution of nanostructure in this particular specimen is 2.5 nm.

36 MATERIALS SCIENCE↗

Scanning Josephson spectroscopy on the atomic scale

The Josephson effect provides a direct method to probe the strength of the pairing interaction in superconductors. By measuring the phase fluctuating Josephson current between a superconducting tip of a scanning tunneling microscope and a BCS superconductor with isolated magnetic adatoms on its surface, we demonstrate that the spatial variation of the pairing order parameter can be characterized on the atomic scale. This system provides an example where the local pairing potential suppression is not directly reflected in the spectra measured via quasiparticle tunneling. Spectroscopy with such superconducting tips also shows signatures of previously unexplored Andreev processes through individual impurity-bound Shiba states. Furthermore, the atomic resolution achieved here establishes scanning Josephson spectroscopy as a promising technique for the study of novel superconducting phases.

Andreev reflection↗

Imaging moiré excited states with photocurrent tunnelling microscopy

Moiré superlattices provide a highly tuneable and versatile platform to explore novel quantum phases and exotic excited states ranging from correlated insulators to moiré excitons. Scanning tunnelling microscopy has played a key role in probing microscopic behaviours of the moiré correlated ground states at the atomic scale. However, imaging of quantum excited states in moiré heterostructures remains an outstanding challenge. In this report we develop a photocurrent tunnelling microscopy technique that combines laser excitation and scanning tunnelling spectroscopy to directly visualize the electron and hole distribution within the photoexcited moiré exciton in twisted bilayer WS 2 . The tunnelling photocurrent alternates between positive and negative polarities at different locations within a single moiré unit cell. This alternating photocurrent originates from the in-plane charge transfer moiré exciton in twisted bilayer WS 2 , predicted by our GW-Bethe–Salpeter equation calculations, that emerges from the competition between the electron–hole Coulomb interaction and the moiré potential landscape. Our technique enables the exploration of photoexcited non-equilibrium moiré phenomena at the atomic scale.

36 MATERIALS SCIENCE↗

Characterizing physical, chemical, and magnetic properties at the nanoscale

Synchrotron light sources are extremely useful for the characterization of materials in many different research fields (including physics, chemistry, materials science, biology, medicine, geology, and cultural heritage). The evolution of technology, however, currently points toward the miniaturization of devices and molecular motors, as well as the creation (through atomic manipulation) of new materials. This brings an acute necessity for direct chemical imaging of materials, i.e., with the use of x-ray microscopy at the nanometer and atomic length scales.1, 2 Although a variety of new x-ray nanoprobes and x-ray microscopy techniques have been developed in recent years, the spatial resolution of direct chemical or magnetic contrast imaging techniques remains on the order of several nanometers. Invented in the 1980s, scanning tunneling microscopy (STM) allows a large range of materials to be viewed at the atomic level.3 STM also offers a finer degree of spatial resolution than almost any other image technique, but it is chemically ‘blind’ and thus cannot be used alone to directly identify chemical elements on a surface. For many years, researchers have attempted to solve this problem by combining STM with synchrotron x-ray excitations,4–7 and a new technique—known as synchrotron xray scanning tunneling microscopy (SX-STM)—has emerged. In this technique—which combines the chemical sensitivity of xrays with the high spatial resolution of STM—a monochromatic x-ray beam is used to illuminate a tip-sample junction, while the tip makes raster scans across the sample surface. A feedback system maintains a tip–sample separation that is typically less than 1nm. The goal is tomodulate the tunneling current through x-ray excitation and therewith obtain electronic and chemical contrast. It is difficult, however, to achieve real chemical contrast because of three serious issues. First, electrons excited by x-rays do not just tunnel into the tip, but can also be ejected from the sample and hit the sidewalls of the tip detector (which degrades the spatial resolution). Second, because photoejected electrons still provide a deceptive current signal in the far field, the STM feedback system can lift the tip out of the tunneling regime without being noticed. Last, themeasured tip current is always a convolution of the conventional tunnel current (which is related to the sample topography) and the x-ray-excited electrons (which carry the material’s chemical information).

36 MATERIALS SCIENCE↗

Real Space Visualization of Competing Phases in La 0.6 Sr 2.4 Mn 2 O 7 Single Crystals

We report that correlated quantum materials are expected to provide the foundation for the next generation of information or energy technologies. A key feature of these materials is the proximity of multiple ground states close in energy, which results in the ability to tune properties with small changes in an external parameter such as magnetic field, composition, or temperature. For example, the colossal magnetoresistance exhibited by manganites is related to charge and orbital ordering and results from a metallic ferromagnetic phase in proximity to a paramagnetic insulating phase. The presence of competing ground states, at the heart of the physics and functionality of these materials, often results in nanoscale phase separation. Probing nanoscale phase separation with conventional diffraction techniques alone is not adequate, particularly when the domains are small or nanosized. In the present work we use a scanning transmission electron microscopy image-based technique of picometer precision strain maps (PPSM) to directly visualize the competing nanoscale phases with charge and orbital ordering in a double-layer manganite. Finally, this work underscores the role of subtle structural distortions in determining the electron physics in correlated quantum materials and provides insights into designing new functionalities via spatially tuning multiple competing ground states.

36 MATERIALS SCIENCE↗

Facile fabrication of novel silver-polypyrrole-multiwall carbon nanotubes nanocomposite for replacement of platinum in dye-sensitized solar cell

This paper demonstrates the facile synthesis of high performance silver-polypyrrole-multiwall carbon nanotubes (Ag-PPy-FMWCNTS) nanocomposites via electrodeposition method on stainless steel substrate and its application as a low cost counter electrode (CE) for the precious platinum (Pt) free DSSC. The nanocomposites were characterized by variety of techniques such as Fourier transforms infrared (FTIR), X-ray diffraction, Scanning electron microscope (SEM), cyclic voltammetry (CV) and Four probe technique respectively. The cyclic voltammetry and Tafel polymerization measurements of Ag-PPy-FMWCNTS nanocomposites CE reveal the favorable electrocatalytic activity and low charge transfer resistance R{sub ct}(2.50 Ω cm{sup 2}) for I{sub 3}{sup −}/I{sup −} redox solution. The four probe studies showed the large electrical conductivity (226S cm{sup −1}) of Ag-PPy-FMWCNTS nanocomposite. The DSSC assembled with Ag-PPy-FMWCNTS nanocomposites CE display the considerable short circuit current density (13.95 mA cm{sup −2}) and acceptable solar to electrical conversion efficiency of 7.6%, which is higher to the efficiency of DSSC with thermally decomposed Pt reference electrode 7.1%. The excellent conversion efficiency, rapid charge transfer in combination with low cost and simple fabrication method of Ag-PPy-FMWCNTS nanocomposites can be exploited as an efficient and potential candidate to replace the Pt CE for large scale production of DSSC.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Correlative Electron and Fluorescence Microscopy of Magnetotactic Bacteria in Liquid: Toward In Vivo Imaging

Magnetotactic bacteria biomineralize ordered chains of uniform, membrane-bound magnetite or greigite nanocrystals that exhibit nearly perfect crystal structures and species-specific morphologies. Transmission electron microscopy (TEM) is a critical technique for providing information regarding the organization of cellular and magnetite structures in these microorganisms. However, conventional TEM can only be used to image air-dried or vitrified bacteria removed from their natural environment. Here we present a correlative scanning TEM (STEM) and fluorescence microscopy technique for imaging viable cells of Magnetospirillum magneticum strain AMB-1 in liquid using an in situ fluid cell TEM holder. Fluorescently labeled cells were immobilized on microchip window surfaces and visualized in a fluid cell with STEM, followed by correlative fluorescence imaging to verify their membrane integrity. Notably, the post-STEM fluorescence imaging indicated that the bacterial cell wall membrane did not sustain radiation damage during STEM imaging at low electron dose conditions. We investigated the effects of radiation damage and sample preparation on the bacteria viability and found that approximately 50% of the bacterial membranes remained intact after an hour in the fluid cell, decreasing to ~30% after two hours. These results represent a first step toward in vivo studies of magnetite biomineralization in magnetotactic bacteria.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mapping charge excitations in generalized Wigner crystals

Transition metal dichalcogenide-based moiré superlattices exhibit strong electron-electron correlations, thus giving rise to strongly correlated quantum phenomena such as generalized Wigner crystal states. Evidence of Wigner crystals in transition metal dichalcogenide moire superlattices has been widely reported from various optical spectroscopy and electrical conductivity measurements, while their microscopic nature has been limited to the basic lattice structure. Theoretical studies predict that unusual quasiparticle excitations across the correlated gap between upper and lower Hubbard bands can arise due to long-range Coulomb interactions in generalized Wigner crystal states. However, the microscopic proof of such quasiparticle excitations is challenging because of the low excitation energy of the Wigner crystal. Here, in this study, we describe a scanning single-electron charging spectroscopy technique with nanometre spatial resolution and single-electron charge resolution that enables us to directly image electron and hole wavefunctions and to determine the thermodynamic gap of generalized Wigner crystal states in twisted WS 2 moiré heterostructures. High-resolution scanning single-electron charging spectroscopy combines scanning tunnelling microscopy with a monolayer graphene sensing layer, thus enabling the generation of individual electron and hole quasiparticles in generalized Wigner crystals. We show that electron and hole quasiparticles have complementary wavefunction distributions and that thermodynamic gaps of ~50 meV exist for the 1/3 and 2/3 generalized Wigner crystal states in twisted WS 2 .

36 MATERIALS SCIENCE↗

Magnetic field driven emergent phenomena: Insights from magneto-optics and nanoscopy

This review explores magnetic field-driven emergent phenomena across various material systems, emphasizing the pivotal roles of magneto-optical and nanoscopy techniques. We examine fundamental aspects of Landau electrodynamics in both 2D and 3D systems, including quantum Hall and topological magnetoelectric effects in graphene and topological insulators. Particularly attention is given to magnetic excitations and magnetopolaritons, such as surface magnon polaritons, magnetoplasmons, and magnetoexcitons in novel quantum materials, including quantum magnets and hybrid heterostructures. Advanced imaging techniques, such as scattering-type scanning near-field optical microscopy (SNOM) and microwave impedance microscopy, are showcased for their capability to resolve these phenomena with microscopic and nanoscopic resolution. These insights are complemented by discussions of advanced experimental approaches, including cryogenic environments, ultrafast pump-probe techniques, and the integration of magnetic fields into near-field optical methodologies. We further investigate the potential of these imaging techniques for unraveling complex magnetic orders, quantum phases, and correlated electronic behaviors. Finally, we offer perspectives on future research directions and highlight emerging opportunities in the evolving field of optical magneto-nanoscopy.

36 MATERIALS SCIENCE↗

Iodine Capture Studies of Silver Mordenite and Novel Alternative Metal Sorbents

Radioiodine is one of the radionuclides of concern when considering reprocessing of used nuclear fuel (UNF). It is expected to be released primarily in the dissolver off-gas (DOG) stream. Sorbents that target I 2 removal from a UNF processing off gas must perform efficiently under elevated temperatures in the presence of water vapor and nitrogen oxide gasses (NOx). Many studies have been conducted that examine the adsorption of iodine species in the presence of NOx gases through reduced silver-exchanged mordenite (Ag 0 Z), a zeolite mineral. This study characterizes the effects of iodine, water vapor, and nitrogen dioxide on the adsorption of I 2 by Ag 0 Z at lower temperatures suitable for comparison with novel Cu- and Bi- bearing sorbents which offer a non-RCRA alternative. When exposed to ‘harsh’ conditions such as I 2 , H 2 O, and NO 2 vapors carried by air, Cu 2 S-polyacrylonitrile (PAN) is more efficient than Ag 0 Z and all other novel sorbents, providing with 11% I capture efficiency. However, under ‘ideal’ conditions in which I 2 is carried by dry air), Ag 0 Z is more efficient than Cu 2 S-PAN and other novel sorbents, providing 74% I capture efficiency. To investigate this result and the overall performance of all sorbents tested, several characterization techniques were employed, including thermal gravimetric analysis, scanning electron microscopy – electron dispersion X-Ray spectroscopy, powder X-ray diffraction, and X-ray photoelectron spectroscopy. These techniques are discussed within this report. This document also includes a design and test plan update from Idaho National Laboratory as the next step in testing the high performing sorbents from thin-bed tests carried out by Oak Ridge National Laboratory.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

TU-G-204-01: BEST IN PHYSICS (IMAGING): Dynamic CT Myocardial Perfusion Measurement and Its Comparison to Fractional Flow Reserve

Purpose: To evaluate a first pass analysis (FPA) technique for CT perfusion measurement in a swine animal and its validation using fractional flow reserve (FFR) as a reference standard. Methods: Swine were placed under anesthesia and relevant physiologic parameters were continuously recorded. Intra-coronary adenosine was administered to induce maximum hyperemia. A pressure wire was advanced distal to the first diagonal branch of the left anterior descending (LAD) artery for FFR measurements and a balloon dilation catheter was inserted over the pressure wire into the proximal LAD to create varying levels of stenosis. Images were acquired with a 320-row wide volume CT scanner. Three main coronary perfusion beds were delineated in the myocardium using arteries extracted from CT angiography images using a minimum energy hypothesis. The integrated density in the perfusion bed was used to calculate perfusion using the FPA technique. The perfusion in the LAD bed over a range of stenosis severity was measured. The measured fractional perfusion was compared to FFR and linear regression was performed. Results: The measured fractional perfusion using the FPA technique (P-FPA) and FFR were related as P-FPA = 1.06FFR – 0.06 (r{sup 2} = 0.86). The perfusion measurements were calculated with only three to five total CT volume scans, which drastically reduces the radiation dose as compared with the existing techniques requiring 15–20 volume scans. Conclusion: The measured perfusion using the first pass analysis technique showed good correlation with FFR measurements as a reference standard. The technique for perfusion measurement can potentially make a substantial reduction in radiation dose as compared with the existing techniques.

60 APPLIED LIFE SCIENCES↗

Imaging of the surface resistance of an SRF cavity by low-temperature laser scanning microscopy

Temperature mapping of the outer surface of a superconducting radio-frequency cavity is a technique that is often used to identify lossy areas on the cavity surface. In this contribution, we present 2-D images of the superconducting state surface resistance R{sub s} of the inner surface of a superconducting radio-frequency (SRF) cavity obtained by low-temperature laser scanning microscopy. This technique, which is applied for the first time to study lossy regions in an operating SRF cavity, allows identifying 'hotspots' with about one order of magnitude better spatial resolution ( ~2 mm) than by thermometry. The R{sub s}-resolution is of the order of 1 {micro}{Ohm} at 3.3 GHz. Surface resistance maps with different laser power and optical images of the cavity surface are discussed in this contribution. It is also shown that the thermal gradient on the niobium surface created by the laser beam can move some of the hotspots, which are identified as locations of trapped bundle of fluxoids. The prospects for this microscope to identify defects that limit the performance of SRF cavities will also be discussed.

Laser scanning microscopy↗

Single-particle scattering spectroscopy: fundamentals and applications

Metallic nanoparticles supporting a localized surface plasmon resonance have emerged as promising platforms for nanoscopic labels, sensors, and (photo-) catalysts. To use nanoparticles in these capacities, and to gain mechanistic insight into the reactivity of inherently heterogeneous nanoparticles, single-particle characterization approaches are needed. Single-particle scattering spectroscopy has become an important, highly sensitive tool for localizing single plasmonic nanoparticles and studying their optical properties, local environment, and reactivity. In this review, we discuss approaches taken for collecting the scattered light from single particles, their advantages and disadvantages, and present some recent applications. We introduce techniques for the excitation and detection of single-particle scattering such as high-angle dark-field excitation, total internal reflection dark-field excitation, scanning near-field microscopy, and interferometric scattering. We also describe methods to achieve polarization-resolved excitation and detection. We then discuss different approaches for scanning, ratiometric, snapshot, and interferometric hyperspectral imaging techniques used to extract spectral information. Finally, we provide a brief overview of specialized setups for in situ measurements of nanoparticles in liquid systems and setups coupled to scanning tip microscopes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Polyacids as Modulators for the Synthesis of UiO-66

Poly(acrylic acid) (PAA) and poly(vinylbenzoic acid) (PBA) were synthesized via reversible addition–fragmentation chain transfer (RAFT) polymerization and used as modulators for the synthesis of the metal–organic framework (MOF) UiO-66 (UiO = University of Oslo). Whereas typical syntheses of UiO-66 require large excesses of acid modulators, such as acetic acid or benzoic acid, to achieve controlled particle size and morphology of the resulting MOF particles, the use of polymerized acids allows for narrow particle size distributions at sub-stoichiometric quantities of modulator. Here, we show using scanning electron microscopy and dynamic light scattering techniques that polyacids can act as alternative modulators for the growth of UiO-66.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Toward accurate measurement of electromagnetic field by retrieving and refining the center position of non-uniform diffraction disks in Lorentz 4D-STEM

Recent advancement in scanning transmission electron microscopy (STEM) allows the use of 4D-STEM, a technique that captures an electron diffraction pattern at each scan point in STEM, to measure electrostatic and magnetic potential and field in materials. However, accurate measurement, separation of the magnetic and electric signals, and removal of artifacts remain challenging, especially in the presence of complex non-uniform diffraction contrast within the disks. In this work, based on dynamic simulations of 4D-STEM patterns built upon superstructures consisting of millions of atoms to account for different sample thickness and edge geometries, we show how the shape and intensity distribution of the central disk are affected by multiple scattering. We propose a robust refinement procedure through iteration of the spin-sensitive peak position of the disk-center in the circular Hough transform filtered images from experimental Lorentz 4D-STEM dataset after minimizing the possible artifacts, such as those due to the change of thickness, dynamic scattering, and scanning process. We verify that caution must be taken as in practice the rigid-disk-shift model used to reconstruct induction maps can easily break down due to disk-protrusion when there exists a nonconstant phase gradient or thickness within the width of the probe. Through quantitative analysis and comparing experiment with calculation the effect of the non-spin-related intensity distribution inside the disk as well as that causes the disk shift due to the intensity-protrusion can be removed, and high-quality magnetic field mapping is possible.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-F-T-123: The Simulated Effect of the Breath-Hold Reproducibility Treating Locally-Advanced Lung Cancer with Pencil Beam Scanned Proton Therapy

Purpose: The breath-hold (BH) technique has been suggested to mitigate motion and reduce target coverage degradation due to motion effects. The aim of this study was to investigate the effect of inter-BH residual motion on the dose distribution for pencil beam scanned (PBS) proton therapy of locally-advanced lung cancer patients. Methods: A dataset of visually-guided BH CT scans was acquired (10 scans per patient) taken from five lung cancer patients: three intra-fractionally repeated CT scans on treatment days 2,16 and 31, in addition to the day 0 planning CT scan. Three field intensity-modulated proton therapy (IMPT) plans were constructed on the planning CT scan. Dose delivery on fraction 2, 16 and 31 were simulated on the three consecutive CT scans, assuming BH duration of 20s and soft tissue match. The dose was accumulated in the planning CT using deformable image registration, and scaled to simulate the full treatment of 66Gy(RBE) in 33 fractions. Results: The mean dose to the lungs and heart, and maximum dose to the spinal cord and esophagus were within 1% of the planned dose. The CTV V95% decreased and the inhomogeneity (D5%–D95%) increased on average 4.1% (0.4–12.2%) and 5.8% (2.2–13.4%), respectively, over the five patient cases. Conclusion: The results showed that the BH technique seems to spare the OARs in spite of inter-BH residual motion. However, small degradation of target coverage occurred for all patients, with 3/5 patients having a decrease in V95% ≤1%. For the remaining two patients, where V95% decreased up to 12%, the cause could be related to treatment related anatomical changes and, as in photon therapy, plan adaptation may be necessary to ensure target coverage. This study showed that BH could be a potential treatment option to reliably mitigate motion for the treatment of locally-advanced lung cancer using PBS proton therapy.

60 APPLIED LIFE SCIENCES↗

Machine Learning for Optical Scanning Probe Nanoscopy

Abstract The ability to perform nanometer‐scale optical imaging and spectroscopy is key to deciphering the low‐energy effects in quantum materials, as well as vibrational fingerprints in planetary and extraterrestrial particles, catalytic substances, and aqueous biological samples. These tasks can be accomplished by the scattering‐type scanning near‐field optical microscopy (s‐SNOM) technique that has recently spread to many research fields and enabled notable discoveries. Herein, it is shown that the s‐SNOM, together with scanning probe research in general, can benefit in many ways from artificial‐intelligence (AI) and machine‐learning (ML) algorithms. Augmented with AI‐ and ML‐enhanced data acquisition and analysis, scanning probe optical nanoscopy is poised to become more efficient, accurate, and intelligent.

Chen, Xinzhong↗

4D in-beam positron emission tomography for verification of motion-compensated ion beam therapy

Purpose: Clinically safe and effective treatment of intrafractionally moving targets with scanned ion beams requires dedicated delivery techniques such as beam tracking. Apart from treatment delivery, also appropriate methods for validation of the actual tumor irradiation are highly desirable. In this contribution the feasibility of four-dimensionally (space and time) resolved, motion-compensated in-beam positron emission tomography (4DibPET) was addressed in experimental studies with scanned carbon ion beams. Methods: A polymethyl methracrylate block sinusoidally moving left-right in beam's eye view was used as target. Radiological depth changes were introduced by placing a stationary ramp-shaped absorber proximal of the moving target. Treatment delivery was compensated for motion by beam tracking. Time-resolved, motion-correlated in-beam PET data acquisition was performed during beam delivery with tracking the moving target and prolonged after beam delivery first with the activated target still in motion and, finally, with the target at rest. Motion-compensated 4DibPET imaging was implemented and the results were compared to a stationary reference irradiation of the same treatment field. Data were used to determine feasibility of 4DibPET but also to evaluate offline in comparison to in-beam PET acquisition. Results: 4D in-beam as well as offline PET imaging was found to be feasible and offers the possibility to verify the correct functioning of beam tracking. Motion compensation of the imaged {beta}{sup +}-activity distribution allows recovery of the volumetric extension of the delivered field for direct comparison with the reference stationary condition. Observed differences in terms of lateral field extension and penumbra in the direction of motion were typically less than 1 mm for both imaging strategies in comparison to the corresponding reference distributions. However, in-beam imaging retained a better spatial correlation of the measured activity with the delivered dose. Conclusions: 4DibPET is a feasible and promising method to validate treatment delivery of scanned ion beams to moving targets. Further investigations will focus on more complex geometries and treatment planning studies with clinical data.

61 RADIATION PROTECTION AND DOSIMETRY↗