Search NASA⌕ Search

SEARCH · Search NASA

Results for “System Operator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

Dynamic Complexity Study of Nuclear Reactor and Process Heat Application Integration

Abstract This paper describes the key obstacles and challenges facing the integration of nuclear reactors with process heat applications as they relate to dynamic issues. The paper also presents capabilities of current modeling and analysis tools available to investigate these issues. A pragmatic approach to an analysis is developed with the ultimate objective of improving the viability of nuclear energy as a heat source for process industries. The extension of nuclear energy to process heat industries would improve energy security and aid in reduction of carbon emissions by reducing demands for foreign derived fossil fuels. The paper begins with an overview of nuclear reactors and process application for potential use in an integrated system. Reactors are evaluated against specific characteristics that determine their compatibility with process applications such as heat outlet temperature. The reactor system categories include light water, heavy water, small to medium, near term high-temperature, and far term high temperature reactors. Low temperature process systems include desalination, district heating, and tar sands and shale oil recovery. High temperature processes that support hydrogen production include steam reforming, steam cracking, hydrogen production by electrolysis, and far-term applications such as the sulfur iodine chemical process and high-temperature electrolysis. A simple static matching between complementary systems is performed; however, to gain a true appreciation for system integration complexity, time dependent dynamic analysis is required. The paper identifies critical issues arising from dynamic complexity associated with integration of systems. Operational issues include scheduling conflicts and resource allocation for heat and electricity. Additionally, economic and safety considerations that could impact the successful integration of these systems are considered. Economic issues include the cost differential arising due to an integrated system and the economic allocation of electricity and heat resources. Safety issues include changes in regulatory constraints imposed on the facilities. Modeling and analysis tools, such as System Dynamics for time dependent operational and economic issues and RELAP5 3D for chemical transient affects, are evaluated. The results of this study advance the body of knowledge toward integration of nuclear reactors and process heat applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

District Energy Corporation SW 40th Street Thermal Energy Plant

The overall deliverable from the project is the design, construction and commissioning of a detention facility heating and cooling system that minimizes ownership costs and maximizes efficiency (and therefore minimizes environmental impact). The primary deliverables were the proof of concept for the application of geothermal systems for an institutional facility and the ongoing, quarterly system operating data downloads to the Department of Energy . The primary advantage of geothermal based heat pump systems is the higher efficiency of the system compared to a conventional chiller, boiler, cooling tower based system. The higher efficiency results in a smaller environmental foot print and lower energy costs for the detention facility owner, Lancaster County. The higher efficiency for building cooling is primarily due to a more constant compressor condensing temperature with the geothermal well field acting as a thermal “sink” (in place of the conventional system’s cooling tower). In the heating mode, Ground Couple Heat Pump (GCHP) systems benefits from the advantage of a heat pump Coefficient of Performance (COP) of approximately 3.6, significantly better than a conventional gas boiler. The geothermal well field acting as a thermal “source” allows the heat pumps to operate efficiently in the heating mode regardless of ambient temperatures. The well field is partially located in a wetland with a high water table so, over time, the project will be able to identify the thermal loading characteristics of a well field located in a high water table location. The project demonstrated how a large geothermal well field can be installed in a wetland area in an economical and environmentally sound manner. Finally, the SW 40th Street Thermal Energy Plant project demonstrates the benefits of providing domestic hot water energy, as well as space heating, to help balance well filed thermal loading in a cooling dominated application. During the period of August 2012 thru March 2014, with the detention facility occupied for the final seven months, the well field supply water temperatures to the heat pumps dropped to a minimum of 39°F and reached a maximum temperature of 68 °F while providing 15,819 MMBtu of cooling energy and 27,467 MMBtu of heating energy. During this period the peak recorded system cooling load was 610 tons and the peak heating load was 8.4 MMBtu. The DEC is currently evaluating the most beneficial electric rate for plant operations. Total project cost of $16.9 million was approximately $3.2 million less than the estimate provided in the grant application. The reduction in project costs were primarily due to favorable construction material prices as well as strong competition in the local construction contractor market. The DEC plant reached the substantial completion milestone in December 2011 and began providing thermal service to the detention facility in January 2012 when the building’s HVAC system was ready to accept heating service. The plant reached commercial operating status on August 1, 2012. However, due to construction delays, the detention facility was not occupied until September of 2013. The detention facility construction delays also impacted the installation and commissioning of the project’s dedicated domestic hot water heat pump. Final coordination with the detention facility’s building management system vendor to establish network links for the exchange of date is currently being completed. This will allow the development of control sequences for the optimal operation of the domestic hot water system.

15 GEOTHERMAL ENERGY↗

Human Supervision of Autonomous Vehicle Fleet Operations and Associated Passenger Communications: Preprint

Advances in automated vehicle (AV) technology and expanded operations are rapidly emerging with Automated Mobility District (AMD) deployments in global cities. NLR's AMD research addresses critical elements of human supervision of AV fleet operations and associated passenger communications for vehicles in which no driver or safety attendant is present. Although sufficiently advanced AVs no longer have direct oversight by a driver, fleet management remains staffed with operations personnel at the operations command and control (OCC) facility. This paper examines the functionality of the OCC, drawing comparisons of how automated train control and automated people mover OCCs operate. Within an AMD, the OCC manages various vehicle types, sizes, and operational modes, including on-demand and fixed route service, to facilitate a 'network of networks' for transport within a metropolitan area. The OCC serves as oversight for multiple AV fleets assisting AVs via remote operation of vehicles, communication, and dispatching personnel to resolve problems. The OCC also coordinates system operation, geographically staging vehicles, and managing weather, police, and emergency events. Informed by traffic management center (TMC) strategies using highly integrated software and communications, OCCs facilitate seamless information flows. OCC personnel remotely assist passengers and oversee multi-party operation to ensure safety and security. Although social norms mitigate large-capacity unattended vehicle operations, social interaction in multi-party automated small vehicles has little precedent. This poses a new frontier for society and requires research to effectively understand and manage. Future research will monitor OCC implementations, passenger interfaces, and deployment scaling of initial AMD systems.

33 ADVANCED PROPULSION SYSTEMS↗

Controllable Grid Interface for Testing Ancillary Service Controls and Fault Performance of Utility-Scale Wind Power Generation: Preprint

The rapid expansion of wind power has led many transmission system operators to demand modern wind power plants to comply with strict interconnection requirements. Such requirements involve various aspects of wind power plant operation, including fault ride-through and power quality performance as well as the provision of ancillary services to enhance grid reliability. During recent years, the National Renewable Energy Laboratory (NREL) of the U.S. Department of Energy has developed a new, groundbreaking testing apparatus and methodology to test and demonstrate many existing and future advanced controls for wind generation (and other renewable generation technologies) on the multimegawatt scale and medium-voltage levels. This paper describes the capabilities and control features of NREL's 7-MVA power electronic grid simulator (also called a controllable grid interface, or CGI) that enables testing many active and reactive power control features of modern wind turbine generators -- including inertial response, primary and secondary frequency responses, and voltage regulation -- under a controlled, medium-voltage grid environment. In particular, this paper focuses on the specifics of testing the balanced and unbalanced fault ride-through characteristics of wind turbine generators under simulated strong and weak medium-voltage grid conditions. In addition, this paper provides insights on the power hardware-in-the-loop feature implemented in the CGI to emulate (in real time) the conditions that might exist in various types of electric power systems under normal operations and/or contingency scenarios. Using actual test examples and simulation results, this paper describes the value of CGI as an ultimate modeling validation tool for all types of 'grid-friendly' controls by wind generation.

17 WIND ENERGY↗

Operational control with set-points tuning - application to mobile robots

This paper proposes a novel method for the optimal tuning of set points for multiple-layered control system structure widely seen in robotics and other complex industrial processes composed of a number of subsystems. The terminal sliding mode control (SMC) is used as the low-level control strategy to ensure the stability of subsystems. When uncertainties exist, it can be shown that the deteriorated system performance will be improved by the outer loop with set points tuning. For this purpose, the learning of the new set point is designed to compensate for the effects caused by uncertainties during the system operation. At the same time, the system is proven to stay with the original set point when the compensation is introduced. A practical application to a holonomic mobile robot system is given to illustrate the presented method. Desired results have been obtained.

42 ENGINEERING↗

Tri-level hybrid interval-stochastic optimal scheduling for flexible residential loads under GAN-assisted multiple uncertainties

Various building loads, such as heating, ventilation, and air conditioners (HVACs), electric water heaters (EWHs), and electric vehicles (EVs), can introduce opportunities for improving the flexibility of electricity consumption while satisfying the needs of building owners as well as benefiting the resilience of distribution system. To utilize such flexibility, a tri-level distribution market framework is established, including residential consumers, load aggregators (LAs), and the distribution system operator (DSO). In this work, the uncertainties from all three levels are considered. The random consumption behavior at the consumer level is modeled as a Gaussian noise that is also aggregated and transmitted to the LA level. The weather temperature in the LA level is forecasted as an interval, and the photovoltaic (PV) power in the market-clearing level is modeled by a set of power scenarios generated by Generative Adversarial Networks (GANs). Then, a hybrid interval-stochastic programming is proposed to transform the uncertain problems in the first two levels into deterministic ones. For real-time implementations, a rolling horizon optimization (RHO) scheme is employed to continuously optimize the power consumption based on the latest operating information. Finally, case studies on a modified IEEE 69-bus system validate the effectiveness of the proposed uncertainty modeling strategies and the RHO scheme.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Autonomous Reactivity Control (ARC) — Principles, geometry and design process

The Autonomous Reactivity Control (ARC) system was developed to ensure inherent safety performance of Generation-IV reactors while having a minimal impact on reactor performance and economic viability. Here we present in detail the principles of how the ARC system operates, what materials should be used, what components make up the system and how they are interconnected. The relevant equations regarding how to design the system for a certain response are developed and defined, and the most important aspects determining the speed of actuation of the systems are analyzed. Thus, this study serves as the general reference material for all of the fundamental principles behind the ARC idea. Finally, we present a step-by-step guide to how a fast reactor fuel subassembly with an ARC system installed would be manufactured, using a full 3D-CAD model. For an ARC installation in a 1000 MWth sodium-cooled oxide-fueled fast reactor core, the system constitutes a relatively minor adjustment to a typical fuel assembly, increasing its total axial extent by ~5–10% and the total primary coolant pressure drop by ~1%. In conclusion, the main finding of this study is that it is possible to design, manufacture (using existing methods) and implement ARC systems in the fuel assemblies of fast reactor cores to provide inherent safety in all anticipated unprotected transients with only a modest increase in the length of the assembly and the pressure drop across the core.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Hydroclimate-coupled framework for assessing power system resilience under summer drought and climate change

Extreme drought, exacerbated by climate change, increasingly threatens power system resilience, and a systematic assessment of such impacts is challenging due to the unpredictability of drought and their associated modeling complexity. Here, to address the challenge, this research develops a hydroclimate-coupled power system resilience assessment framework that enables systematic modeling of drought and climate change impacts on generation, transmission, and demand sectors. Applying the framework to the 2025 Eastern U.S. power grid — comprising 6,055 at-risk generators — under climate-induced summer drought scenarios (including SSP126, SSP245, SSP370, and SSP585) from 2023 to 2100, the study finds that climate-induced droughts could jeopardize the power system’s reliability to a greater extent than historical events, potentially leading to widespread load shedding. More specifically, the study reveals that under the twenty-one representative drought scenarios, the loss of load expectation (LOLE) of the grid could range from 34.77 to 91.48 days per summer. The simulations indicate that implementing resilience enhancement strategies is crucial to ensure reliable system operation, which encompasses initiatives such as demand response, upgrading open cooling systems, and transmission expansion. In all, these findings underscore the urgent need for proactive planning and investment in resilient U.S. power systems to mitigate the impacts of extreme drought events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal Litz Wire Design for High-Power Wireless Charging System

In this study, an optimized Litz wire and polyphase coil winding design is proposed for high-power wireless charging systems operating at 85 kHz frequency. Litz wire in a wireless charging system contributes to more than half of the losses of the system, making it a critical design component. Here, the Litz wire is optimized through Finite Element Analysis (FEA) considering electrical and mechanical design aspects and the design was validated through experimental tests on different Litz wires with various strand-diameters, twisting ratio, and number of strands. The proposed optimal Litz wire maximizes the system efficiency considering the tradeoff between coil resistance and mutual inductance. The optimal Litz wire shows that Litz wire constructed with the 63µm strands significantly outperform the traditionally used Litz wire with 100µm strand diameter. Additionally, the coil with optimal Litz wire design shows 60% reduction in the copper volume for the same loss, and at the same time increase the coil-to-coil efficiency by more than 2% by increasing the mutual inductance and reducing coil current. The optimized Litz wire was implemented in a 22-kW wireless charging system achieving 94.7% efficiency.

Aydin, Emrullah [ORNL]↗

Interoperability and the Federal Role

A smart grid is capable of integrating a broad array of generation resources and enables the participation of demand side resources in reliable system operation. To cost effectively realize this flexibility, the associated devices and systems need to connect and interact simply and reliably. Interoperability is the important ingredient to make this happen. Because the electric system transcends organizational boundaries between generators, electricity delivery companies, end-users, and other service providers, advancing interoperability between these organizations can be difficult to justify by individual organizations. But given the importance of a smart electric system to meet national economic, societal, and environmental objectives, a federal role is taking shape in the United States to improve the integration of automation elements and thus make smart grid a reality

99 GENERAL AND MISCELLANEOUS↗

A Testbed for Deploying Distributed State Estimation in Power Grid

Abstract—With the increasing demand, scale and data information of power systems, fast distributed applications are becoming more important in power system operation and control. This paper proposes a testbed for evaluating power system distributed applications, considering data exchange among distributed areas. A high-performance computing (HPC) version of distributed state estimation is implemented and used as a distributed application example. The IEEE 118-bus system is used to deploy the parallel distributed state estimation, and the MeDICi middleware is used for data communication. The performance of the testbed demonstrates its capability to evaluate parallel distributed state estimation by leveraging the HPC paradigm. This testbed can also be applied to evaluate other distributed applications.

distributed state estimation↗

Machine Learning-Based Prediction of Distribution Network Voltage and Sensor Allocation

Increasing penetration levels of fast-varying energy resources might negatively affect power system operation. At the same time, sensor deployment throughout distribution networks improves system awareness and enables the development of new and advanced voltage control solutions. Such control techniques rely on accurate prediction in anticipation of voltage violation scenarios. This paper analyzes various approaches to voltage prediction in a distribution system, and it is shown that combining multiple techniques into a single regressor improves its predictive power. Moreover, a two-step regressor is proposed in which initial predictions based on a global regressor are refined by local regressors; in this case, prediction errors decrease significantly. Additionally, a clustering approach is employed to perform sensor allocation so that only the most influential buses are selected for monitoring without diminishing prediction accuracy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterizing Output Bottlenecks of a Production Supercomputer: Analysis and Implications

This article studies the I/O write behaviors of the Titan supercomputer and its Lustre parallel file stores under production load. The results can inform the design, deployment, and configuration of file systems along with the design of I/O software in the application, operating system, and adaptive I/O libraries.We propose a statistical benchmarking methodology to measure write performance across I/O configurations, hardware settings, and system conditions. Moreover, we introduce two relative measures to quantify the write-performance behaviors of hardware components under production load. In addition to designing experiments and benchmarking on Titan, we verify the experimental results on one real application and one real application I/O kernel, XGC and HACC IO, respectively. These two are representative and widely used to address the typical I/O behaviors of applications.In summary, we find that Titan’s I/O system is variable across the machine at fine time scales. This variability has two major implications. First, stragglers lessen the benefit of coupled I/O parallelism (striping). Peak median output bandwidths are obtained with parallel writes to many independent files, with no striping or write sharing of files across clients (compute nodes). I/O parallelism is most effective when the application—or its I/O libraries—distributes the I/O load so that each target stores files for multiple clients and each client writes files on multiple targets in a balanced way with minimal contention. Second, our results suggest that the potential benefit of dynamic adaptation is limited. In particular, it is not fruitful to attempt to identify “good locations” in the machine or in the file system: component performance is driven by transient load conditions and past performance is not a useful predictor of future performance. For example, we do not observe diurnal load patterns that are predictable.

97 MATHEMATICS AND COMPUTING↗

MCR Container Tools

MathWorks' MATLAB is widely used in academia and industry for prototyping, data analysis, data processing, etc. Many users compile their programs using the MATLAB Compiler to run on workstations/computing clusters via the free MATLAB Compiler Runtime (MCR). The MCR facilitates the execution of code calling Application Programming Interfaces (API) functions from both base MATLAB and MATLAB toolboxes. In a Linux environment, a sizable number of third-party runtime dependencies (i.e. shared libraries) are necessary. Unfortunately, to the MTLAB community's knowledge, these dependencies are not documented, leaving system administrators and/or end-users to find/install the necessary libraries either as runtime errors resulting from them missing or by inspecting the header information of Executable and Linkable Format (ELF) libraries of the MCR to determine which ones are missing from the system. To address various shortcomings, Docker Images based on Community Enterprise Operating System (CentOS) 7, a derivative of Redhat Enterprise Linux (RHEL) 7, containing recent (2015-2017) MCR releases and their dependencies were created. These images, along with a provided sample Docker Compose YAML Script, can be used to create a simulated computing cluster where MATLAB Compiler created binaries can be executed using a sample Slurm Workload Manager script.

Haas, NicholasQ↗

Representation of Solar Capacity Value in the ReEDS Capacity Expansion Model

An important issue for electricity system operators is the estimation of renewables' capacity contributions to reliably meeting system demand, or their capacity value. While the capacity value of thermal generation can be estimated easily, assessment of wind and solar requires a more nuanced approach due to the resource variability. Reliability-based methods, particularly assessment of the Effective Load-Carrying Capacity, are considered to be the most robust and widely-accepted techniques for addressing this resource variability. This report compares estimates of solar PV capacity value by the Regional Energy Deployment System (ReEDS) capacity expansion model against two sources. The first comparison is against values published by utilities or other entities for known electrical systems at existing solar penetration levels. The second comparison is against a time-series ELCC simulation tool for high renewable penetration scenarios in the Western Interconnection. Results from the ReEDS model are found to compare well with both comparisons, despite being resolved at a super-hourly temporal resolution. Two results are relevant for other capacity-based models that use a super-hourly resolution to model solar capacity value. First, solar capacity value should not be parameterized as a static value, but must decay with increasing penetration. This is because -- for an afternoon-peaking system -- as solar penetration increases, the system's peak net load shifts to later in the day -- when solar output is lower. Second, long-term planning models should determine system adequacy requirements in each time period in order to approximate LOLP calculations. Within the ReEDS model we resolve these issues by using a capacity value estimate that varies by time-slice. Within each time period the net load and shadow price on ReEDS's planning reserve constraint signals the relative importance of additional firm capacity.

14 SOLAR ENERGY↗

Final Scientific/Technical Report, Multi-Sensor Inspection and Robotic Systems for Dry Storage Casks

Once removed from service, fuel rod assemblies are cooled in a pool and then placed in dry storage until they can be transported to a repository for disposal. The extended duration that used nuclear fuel spends in dry storage makes it prudent to be able to nondestructively inspect the dry storage casks. The degradation mechanisms of most concern are chloride-induced stress corrosion cracking of the stainless steel canister that confines the spent fuel and distributed cracking of the concrete in the overpack structure. Multi-sensor inspection and robotic systems were researched, developed, built, and tested. One system operates completely outside the cask to inspect the concrete. The other system, known as the PRINSE system, for Proactive Robotic Inspection of Nuclear Storage Enclosures, enters the cask through an outlet vent and navigates around the outer surface of the stainless steel canister. The PRINSE system delivers sensors for: (i) real-time characterization of the canister surface in order to assess whether chlorides are present, (ii) detecting the presence of cracks using shear-horizontal ultrasonic guided waves, (iii) measuring the temperature of the canister surface, and (iv) a gamma radiation counter. The four sensing modalities are applicable to any cask containing a stainless steel canister, however the robotic delivery system is designed specifically for Holtec’s HI-STORM family of casks. Horizontal axis casks have exposed concrete surfaces. A fully contactless air-coupled scanning ultrasonic test platform and a frequency-wavenumber domain data analysis method are used for these concrete structures. Analysis, numerical simulation and experimental results demonstrate that distributed cracks in concrete can be detected and cracked regions localized within a scanned region of concrete. Vertical axis casks (like the HI-STORM family) have steel-clad concrete overpacks. In a separate effort, a semi-coupled test platform and a guided wave attenuation-based data analysis method are used for disbond detection. Analysis, numerical simulation and experimental results show that the bonding conditions of steel-concrete interfaces can be quantitatively characterized using the guided wave signal analysis scheme. The PRINSE system is designed for vertical axis dry storage casks, specifically the HI-STORM family. The double pulse laser-induced breakdown spectroscopy (LIBS) system takes advantage of an optical fiber to deliver intense light to the canister surface that enables surface composition characterization in-situ in real time. Chlorine concentrations as low as 10 mg/m2 were detected on stainless steel. Additionally, a simpler laser setup was created to detect sodium as a surrogate for chlorine, and sodium was detectable when the chlorine concentration was as low as 0.5 mg/m2. The electromagnetic acoustic transducers (EMATs) enable detection of stress corrosion cracks. The EMATs generate shear-horizontal waves that propagate around the canister and are reflected by cracks enabling 100% of the canister weld lines to be inspected. The EMAT-based crack detection system was tested at the Pacific Northwest National Laboratory on a canister containing blind defects and was shown to detect the crack sizes it was designed to detect. The PRINSE system is a novel marsupial robot. The command center and winch outside the cask control the delivery arm and train of cars that traverse the outside of the canister from the cask ventilation system. The sensors are housed in the cargo bays of three cars that comprise the train, which is lowered to the bottom of the canister by the winch. Encoders on the winch enable the sensors to be delivered to a prescribed location, e.g., for re-inspection of a problem area. The PRINSE system does not mar the canister surface, can be extracted manually in the case of a power failure, and is designed for an elevated temperature and gamma radiation environment, although not all components of the prototype are made from the final materials. The PRINSE system was tested on a full canister that was placed inside a HI-STORM cask at the Holtec Manufacturing Division. It was also demonstrated on a full-height mockup at Penn State to a live audience.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Detecting Axion Dark Matter with Superconducting Qubits

Axion dark matter haloscopes aim to detect dark matter axions converting to single photons in resonant cavities bathed in a uniform magnetic field. A qubit (two level system) operating as a single microwave photon detector is a viable readout system for such detectors and may offer advantages over the quantum limited amplifiers currently used. When weakly coupled to the detection cavity, the qubit transition frequency is shifted by an amount proportional to the cavity photon number. Through spectroscopy of the qubit, the frequency shift is measured and the cavity occupation number is extracted. At low enough temperatures, this would allow sensitivities exceeding that of the standard quantum limit.

Dixit, Akash↗

Adaptive Model Reduction for Parareal in Time Method for Transient Stability Simulations

Real time or faster than real time simulation can enable system operators to foresee the effect of crucial contingencies on the power system dynamics and take timely actions to prevent system instability. Parareal in time method uses concurrent computations on different segments of the time domain of interest to speed up the dynamic simulations. This paper describes the application of an adaptive nonlinear model reduction method in improving computational speed of the Parareal solver. The proposed method adaptively switches between a hybrid system with selective linearization and a completely linear system based on the size of a disturbance. The functions in the hybrid system are linearized based on the electrical distance between specific generators and the area where disturbances originated. The proposed method is tested on the 327-machine 2383-bus Polish system.

Osipov, Denis↗