Search NASA⌕ Search

SEARCH · Search NASA

Results for “TARGET SIMULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

High energy density micro plasma bunch from multiple laser interaction with thin target

Three-dimensional particle-in-cell simulation is used to investigate radiation-pressure driven acceleration and compression of small solid-density plasma by intense laser pulses. It is found that multiple impacts by presently available short-pulse lasers on a small hemispheric shell target can create a long-living tiny quasineutral monoenergetic plasma bunch of very high energy density.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Robust Vision-based Multi-spacecraft Guidance Navigation and Control using CNN-based Pose Estimation

In this paper, we present an end-to-end simulation framework for tracking an uncooperative Target spacecraft in Low Earth Orbit using a CubeSat-class Ego spacecraft outfitted with a camera. Currently, capturing high-fidelity realistic images in space for this scenario is difficult and exorbitantly expensive. Therefore, we developed a framework to simulate the spacecraft orbits in Basilisk software and generate high-fidelity realistic images of spacecraft in Unreal Engine, including the effects from Sun, Earth, Moon and stars. The Ego spacecraft uses cameras to capture images of the uncooperative Target and estimates its position and attitude using a CNN based 6DOF pose estimation pipeline, eliminating need for large SWAP-C(Size, Weight, Power and Cost) sensors like LIDAR or reliance on inter-spacecraft communication, This CNN, which is motivated by ESA’s Pose Estimation challenge of 2019, is trained using simulated data from our end-to-end simulation framework. We compare the performance of two distinct CNNbased algorithms for pose estimation along a nominal trajectory. In presence of non-Gaussian modeling uncertainties, the statedependent estimation error is characterized with a quadratic upper-bound. The quadratically-bounded error can be used by a robust controller to maneuver

Rahmani, Amir↗

Dosimetric impact of image artifact from a wide-bore CT scanner in radiotherapy treatment planning

Purpose: Traditional computed tomography (CT) units provide a maximum scan field-of-view (sFOV) diameter of 50 cm and a limited bore size, which cannot accommodate a large patient habitus or an extended simulation setup in radiation therapy (RT). Wide-bore CT scanners with increased bore size were developed to address these needs. Some scanners have the capacity to reconstruct the CT images at an extended FOV (eFOV), through data interpolation or extrapolation, using projection data acquired with a conventional sFOV. Objects that extend past the sFOV for eFOV reconstruction may generate image artifacts resulting from truncated projection data; this may distort CT numbers and structure contours in the region beyond the sFOV. The purpose of this study was to evaluate the dosimetric impact of image artifacts from eFOV reconstruction with a wide-bore CT scanner in radiotherapy (RT) treatment planning. Methods: Testing phantoms (i.e., a mini CT phantom with equivalent tissue inserts, a set of CT normal phantoms and anthropomorphic phantoms of the thorax and the pelvis) were used to evaluate eFOV artifacts. Reference baseline images of these phantoms were acquired with the phantom centrally positioned within the sFOV. For comparison, the phantoms were then shifted laterally and scanned partially outside the sFOV, but still within the eFOV. Treatment plans were generated for the thoracic and pelvic anthropomorphic phantoms utilizing the Eclipse treatment planning system (TPS) to study the potential effects of eFOV artifacts on dose calculations. All dose calculations of baseline and test treatment plans were carried out using the same MU. Results: Results show that both body contour and CT numbers are altered by image artifacts in eFOV reconstruction. CT number distortions of up to -356 HU for bone tissue and up to 323 HU for lung tissue were observed in the mini CT phantom. Results from the large body normal phantom, which is close to a clinical patient size, show average CT number changes of up to -49 HU. Wider distribution (i.e., standard deviation) of the HU values was seen when the phantom was placed at more than 2.8 cm beyond the 50 cm sFOV. Anthropomorphic phantom studies with several standard beam configurations show that body contour distortion causes tumor dose calculation reduction of 3.0 and 1.9% for 6 and 23 MV x-rays, respectively, when not accounting for tissue heterogeneities during dose computation. When heterogeneity correction is used in planning, the competing effects of the body contour distortion and the CT number distortion cause a smaller error in tumor dose calculation. Less than 0.9% error in calculated dose was observed in volumetric modulated arc therapy (VMAT) treatment plans. Conclusions: The image artifacts from eFOV reconstruction alter the CT numbers and body contours of the imaged objects, which has the potential to produce inaccuracies in dose calculations during radiotherapy treatment planning. The radiation therapy team should be aware of these image artifacts and their effects on target dose calculations during CT simulation as well as treatment planning.

61 RADIATION PROTECTION AND DOSIMETRY↗

An Investigation into the Transportation of Irradiated Uranium/Aluminum Targets from a Foreign Nuclear Reactor to the Chalk River Laboratories Site in Ontario, Canada - 12249

This investigation required the selection of a suitable cask and development of a device to hold and transport irradiated targets from a foreign nuclear reactor to the Chalk River Laboratories in Ontario, Canada. The main challenge was to design and validate a target holder to protect the irradiated HEU-Al target pencils during transit. Each of the targets was estimated to have an initial decay heat of 118 W prior to transit. As the targets have little thermal mass the potential for high temperature damage and possibly melting was high. Thus, the primary design objective was to conceive a target holder to dissipate heat from the targets. Other design requirements included securing the targets during transportation and providing a simple means to load and unload the targets while submerged five metres under water. A unique target holder (patent pending) was designed and manufactured together with special purpose experimental apparatus including a representative cask. Aluminum dummy targets were fabricated to accept cartridge heaters, to simulate decay heat. Thermocouples were used to measure the temperature of the test targets and selected areas within the target holder and test cask. After obtaining test results, calculations were performed to compensate for differences between experimental and real life conditions. Taking compensation into consideration the maximum target temperature reached was 231 deg. C which was below the designated maximum of 250 deg. C. The design of the aluminum target holder also allowed generous clearance to insert and unload the targets. This clearance was designed to close up as the target holder is placed into the cavity of the transport cask. Springs served to retain and restrain the targets from movement during transportation as well as to facilitate conductive heat transfer. The target holder met the design requirements and as such provided data supporting the feasibility of transporting targets over a relatively long period of time. A suitable transport cask was selected and a device for housing irradiated targets for loading, unloading and transportation has been designed, built and validated. The device was successful in meeting all design requirements for this feasibility study. Experiments were conducted with a custom test facility to confirm that the design met the maximum temperature requirements during shipping. Results from tests showed that the peak temperature in the apparatus was 300 deg. C. By compensating for experimental considerations, such as reduced thermal conductivity of the test cask versus that of the actual cask the expected maximum target temperature reduces to 231 deg. C. This is below the designated peak value of 250 deg. C. It can therefore be concluded, based on the content of this paper and from a heat-removal standpoint, the feasibility of transporting targets from a foreign nuclear reactor to Canada is possible, although further testing with irradiated targets and a full size cask would be a recommended next step. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MC{sup 2}-3/DIF3D Analysis of the ZPPR-15 Axial Expansion Experiments

The Zero Power Physics Reactor (ZPPR) fast critical facility at the Argonne National Laboratory-West (ANLW) site in Idaho was built in 1969 to obtain neutron physics information necessary for the design of fast breeder reactors. The ZPPR-15 phases A through D were part of a series of cores intended to model a 330 MWt Integral Fast Reactor (IFR) concept. The ZPPR-15 assembly consisted of an inner core zone, an outer core zone of higher fissile content, a thin radial blanket and a thick steel reflector. The inner and outer core zones were of approximately equal volumes. The core zones simulated a sodium-cooled, metal-fueled fast reactor with approximately 10 wt.% zirconium in the target fuel composition. Phases A and B simulated an equilibrium cycle UPu-Zr fuel core where plutonium created in the blankets was sufficient to negate the need for enriched {sup 235}U feedstock. Phase D simulated a beginning of life U-Zr fuel core with enriched uranium fuel although approximately 10% of the fuel in the outer zone of the Phase D core was plutonium because {sup 240}Pu was required to provide a neutron source for the modified source multiplication technique used for many reactivity worth measurements such as sodium void worth in ZPPR. Phase C simulated the intermediate state between beginning of life and equilibrium cycle conditions with 50% enriched uranium fuel and 50% plutonium fuel in the inner and outer core zones. These configurations represent the various stages of reactor operating conditions. Phase A did not contain zirconium (metal fuel is typically alloyed with Zr) while Phases B, C and D did contain zirconium although the limited plate inventory restricted the zirconium zone to the inner core zone. This set of experiments was performed between April 1985 and July 1986 and focused on validation of both the concept and modeling. In each phase, there were multiple loadings for sub-critical, critical, and with regard to this manuscript, axial expansion worth measurements. Combined, these cores can be used to assess the accuracy of physics codes and evaluated cross section data for IFR concept reactors. This paper presents a recent effort that was made on retrieving validation data from the ZPPR-15 experiments and on deterministic modeling and analysis using MC{sup 2}-3/DIF3D for code validation. Axial expansion experiments and ZPPR-15D loading 206 were selected for this analysis. An explicit modeling of the axial expansion (introduction of gaps between sections of drawer) of ZPPR-15D loading 206 yielded a 32% over-prediction in the worth of the axial expansion with the MC2-3/DIF3D models. This indicates a consistent bias between ZPPR-15B and ZPPR-15D with regard to the deterministic modeling of the experiments. As part of future work, we intend on investigating whether the cross section processing or homogenization model is to blame, but we note with such small changes in k-effective in a large model, it is rather difficult to obtain zero errors as is typical for other worth measurements. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Low-Z target optimization for spatial resolution improvement in megavoltage imaging

Purpose: Recently, several authors have shown contrast improvements in megavoltage portal imaging and cone-beam computed tomography using low atomic number (Z) targets. This work compliments previous studies by investigating the effects of varying different beam production parameters including target atomic number, target thickness, and incident electron energy on spatial resolution. Methods: Target materials of beryllium, aluminum, and tungsten were investigated over a range of thicknesses between 10% and 100% of the continuous slowing down approximation range of electrons. Incident electron kinetic energies of 4.5 and 7.0 MeV were used, in conjunction with custom targets installed above the carousel of a modern radiotherapy linear accelerator. Monte Carlo simulations of the accelerator were constructed and compared to the experimental results. Results: The results showed that thinner targets, as well higher incident electron energies, generally produce more favorable modulation transfer function (MTF) curves. Due to an MTF dependence of the detector system on the photon energy, the experimental results showed that low-Z targets produced superior MTF curves. Simulations showed 14.5% and 21.5% increases in f{sub 50} for the 7.0 and 4.5 MeV targets (Al; 60%R{sub %CSDA}), respectively, when moved from the carousel to the location of the clinical target. f{sub 50} values for the custom targets were compared to the clinical 6 MV beam and were found to be between 10.4% lower (4.5 MeV/W) and 15.5% higher (7.0 MeV/Be). Conclusions: Integration of low-Z external targets into the treatment head of a medical linear was achieved with only minor modifications. It was shown that reasonably high resolution images on par or better than those acquired with the clinical 6 MV beam can be achieved using external low-Z targets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Auto Code Generation for Simulink-Based Attitude Determination Control System

This paper details the work done to auto generate C code from a Simulink-Based Attitude Determination Control System (ADCS) to be used in target platforms. NASA Marshall Engineers have developed an ADCS Simulink simulation to be used as a component for the flight software of a satellite. This generated code can be used for carrying out Hardware in the loop testing of components for a satellite in a convenient manner with easily tunable parameters. Due to the nature of the embedded hardware components such as microcontrollers, this simulation code cannot be used directly, as it is, on the target platform and must first be converted into C code; this process is known as auto code generation. In order to generate C code from this simulation; it must be modified to follow specific standards set in place by the auto code generation process. Some of these modifications include changing certain simulation models into their atomic representations which can bring new complications into the simulation. The execution order of these models can change based on these modifications. Great care must be taken in order to maintain a working simulation that can also be used for auto code generation. After modifying the ADCS simulation for the auto code generation process, it is shown that the difference between the output data of the former and that of the latter is between acceptable bounds. Thus, it can be said that the process is a success since all the output requirements are met. Based on these results, it can be argued that this generated C code can be effectively used by any desired platform as long as it follows the specific memory requirements established in the Simulink Model.

MolinaFraticelli, Jose Carlos↗

AGR-1 Thermocouple Data Analysis

This report documents an effort to analyze measured and simulated data obtained in the Advanced Gas Reactor (AGR) fuel irradiation test program conducted in the INL's Advanced Test Reactor (ATR) to support the Next Generation Nuclear Plant (NGNP) R&D program. The work follows up on a previous study (Pham and Einerson, 2010), in which statistical analysis methods were applied for AGR-1 thermocouple data qualification. The present work exercises the idea that, while recognizing uncertainties inherent in physics and thermal simulations of the AGR-1 test, results of the numerical simulations can be used in combination with the statistical analysis methods to further improve qualification of measured data. Additionally, the combined analysis of measured and simulation data can generate insights about simulation model uncertainty that can be useful for model improvement. This report also describes an experimental control procedure to maintain fuel target temperature in the future AGR tests using regression relationships that include simulation results. The report is organized into four chapters. Chapter 1 introduces the AGR Fuel Development and Qualification program, AGR-1 test configuration and test procedure, overview of AGR-1 measured data, and overview of physics and thermal simulation, including modeling assumptions and uncertainties. A brief summary of statistical analysis methods developed in (Pham and Einerson 2010) for AGR-1 measured data qualification within NGNP Data Management and Analysis System (NDMAS) is also included for completeness. Chapters 2-3 describe and discuss cases, in which the combined use of experimental and simulation data is realized. A set of issues associated with measurement and modeling uncertainties resulted from the combined analysis are identified. This includes demonstration that such a combined analysis led to important insights for reducing uncertainty in presentation of AGR-1 measured data (Chapter 2) and interpretation of simulation results (Chapter 3). The statistics-based simulation-aided experimental control procedure described for the future AGR tests is developed and demonstrated in Chapter 4. The procedure for controlling the target fuel temperature (capsule peak or average) is based on regression functions of thermocouple readings and other relevant parameters and accounting for possible changes in both physical and thermal conditions and in instrument performance.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Efficient generation of fast ions from surface modulated nanostructure targets irradiated by high intensity short-pulse lasers

It's shown that the imposition of sub-laser wavelength relief structures on the surface of mass-limited-targets results into several folds higher short-pulse laser absorption, and consequently the efficient generation of fast ions. The optimum relief parameters for enhanced short-pulse laser absorption and higher ion acceleration are estimated numerically by particle-in-cell simulations and then corroborated by analytical scalings. The stability of the pre-imposed surface modulation during the laser pulse foil interaction is also examined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Use of a Multiplexed Photonic Doppler Velocimetry (MPDV) System to Study Plastic Deformation of Metallic Steel Plates in High Velocity Impact

High-velocity impact experiments with a gas gun pose unique challenges, in terms of experimental setup and computational simulation, since the projectile-target interaction creates extreme pressure and temperature within few micro seconds. The objective of this study is to accurately measure the plastic deformation of plates under projectile impact that does not lead to full penetration. In this work, free surface velocities at the back side of target plates are measured using the newly developed Multiplexed Photonic Doppler Velocimetry (MPDV) system, which is an interferometric fiber-optic technique which can measure velocity from the Doppler shift of the light reflected from the moving back surface of the target. The MPDV system allows measurements of velocity from different locations on the target plate using multiple optical fiber probes oriented in specific directions and patterns. Data are reduced using a Fast Fourier transformation (FFT) technique to obtain the free surface velocity profiles. These velocity profiles can present insights into the dynamic behavior of impacted materials under shock loading conditions.

MPDV, multiplexing, high-velocity impact, velocime↗

Programmable In Situ System for Iterative Workflows

We describe an in situ system for solving iterative problems. We specifically target inverse problems, where expensive simulations are approximated using a surrogate model. The model explores the parameter space of the simulation through iterative trials, each of which becomes a job managed by a parallel scheduler. Our work extends Henson [1], a cooperative multi-tasking system for in situ execution of loosely coupled codes.

Lohrmann, Erich↗

Single-Channel Current Through Nicotinic Receptor Produced by Closure of Binding Site C-Loop

We investigated the initial coupling of agonist binding to channel gating of the nicotinic acetylcholine receptor using targeted molecular-dynamics (TMD) simulation. After TMD simulation to accelerate closure of the C-loops at the agonist binding sites, the region of the pore that passes through the cell membrane expands. To determine whether the structural changes in the pore result in ion conduction, we used a coarse-grained ion conduction simulator, Biology Boltzmann transport Monte Carlo, and applied it to two structural frames taken before and after TMD simulation. The structural model before TMD simulation represents the channel in the proposed resting state, whereas the model after TMD simulation represents the channel in the proposed active state. Under external voltage biases, the channel in the active state was permeable to cations. Our simulated ion conductance approaches that obtained experimentally and recapitulates several functional properties characteristic of the nicotinic acetylcholine receptor. Thus, closure of the C-loop triggers a structural change in the channel sufficient to account for the open channel current. This approach of applying Biology Boltzmann transport Monte Carlo simulation can be used to further investigate the binding to gating transduction mechanism and the structural bases for ion selection and translocation.

60 APPLIED LIFE SCIENCES↗

Simulation of dark bremsstrahlung in Geant4

A technique for the simulation of dark bremsstrahlung for electrons and muons in GEANT4 is presented. The total cross section is calculated using the Weizsäcker-Williams approximation and the outgoing kinematics are produced by scaling events produced in MadGraph/MadEvent to lower incident lepton energies, allowing the simulation to account for thick targets and lepton sources without fixed energies. In conclusion, compared with dedicated samples produced at an arbitrary particle energy, typical precision of better than 5% is achieved.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Assessment of reverse gun taylor cylinder experimental configuration

Experimental efforts for Taylor-anvil impact tests have often been limited to near room temperature. The ‘Reverse Gun’ method proposed by Gust in 1982 allows for the Taylor impact specimen to be uniformly heated without temperature losses before impact. Through the use of finite element analysis, we explore two topics in this work. First, we examine whether the reverse gun experimental configuration is comparable to the traditional Taylor-anvil setup. Second, we assess the accuracy of several commonly employed flow strength models in terms of their ability to predict the reverse gun experimental results which involve dynamic loading conditions and complex thermo-mechanical coupling. The reverse gun simulations are performed for tantalum targets at initial temperatures in the range 295 K to 1295 K and velocities from 135 m/s to 242 m/s. We show that with suitable care in the modeling of the preheated reverse gun experiments one can make valuable assessments of flow strength models. Given the conditions explored, these observations probe the thermal softening, strain hardening, and strain rate sensitivity of the material.

42 ENGINEERING↗

Treatment of Nasopharyngeal Carcinoma Using Intensity-Modulated Radiotherapy-The National Cancer Centre Singapore Experience

Purpose: The aim of this study was to determine the efficacy and acute toxicity of our early experience with treating nasopharyngeal carcinoma (NPC) patients with intensity-modulated radiotherapy (IMRT). Methods and materials: A review was conducted on case records of 195 patients with histologically proven, nonmetastatic NPC treated with IMRT between 2002 and 2005. MRI of the head and neck was fused with CT simulation images. All plans had target volumes at three dose levels, with a prescribed dose of 70 Gy to the gross disease, in 2.0-2.12 Gy/fraction over 33-35 fractions. Cisplatin-based chemotherapy was offered to Stage III/IV patients. Results: Median patient age was 52 years, and 69% were male. Median follow-up was 36.5 months. One hundred and twenty-three patients had Stage III/IV disease (63%); 50 (26%) had T4 disease. One hundred and eighty-eight (96%) had complete response; 7 (4%) had partial response. Of the complete responders, 10 (5.3%) had local recurrence, giving a 3-year local recurrence-free survival estimate of 93.1% and a 3-year disease-free survival of 82.1%. Fifty-one patients (26%) had at least one Grade 3 toxicity. Conclusions: Results from our series are comparable to those reported by other centers. Acute toxicity is common. Local failure or persistent disease, especially in patients with bulky T4 disease, are issues that must be addressed in future trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility of an Adaptive Strategy in Preoperative Radiochemotherapy for Rectal Cancer With Image-Guided Tomotherapy: Boosting the Dose to the Shrinking Tumor

Purpose: To investigate the feasibility of preoperative adaptive radiochemotherapy by delivering a concomitant boost to the residual tumor during the last 6 fractions of treatment. Methods and Materials: Twenty-five patients with T3/T4N0 or N+ rectal cancer were enrolled. Concomitant chemotherapy consisted of oxaliplatin 100 mg/m{sup 2} on days −14, 0, and +14, and 5-fluorouracil 200 mg/m{sup 2}/d from day −14 to the end of radiation therapy (day 0 is the start of radiation therapy). Radiation therapy consisted of 41.4 Gy in 18 fractions (2.3 Gy per fraction) with Tomotherapy to the tumor and regional lymph nodes (planning target volume, PTV) defined on simulation CT and MRI. After 9 fractions simulation CT and MRI were repeated for the planning of the adaptive phase: PTV{sub adapt} was generated by adding a 5-mm margin to the residual tumor. In the last 6 fractions a boost of 3.0 Gy per fraction (in total 45.6 Gy in 18 fractions) was delivered to PTV{sub adapt} while concomitantly delivering 2.3 Gy per fraction to PTV outside PTV{sub adapt}. Results: Three patients experienced grade 3 gastrointestinal toxicity; 2 of 3 showed toxicity before the adaptive phase. Full dose of radiation therapy, oxaliplatin, and 5-fluorouracil was delivered in 96%, 96%, and 88% of patients, respectively. Two patients with clinical complete response (cCR) refused surgery and were still cCR at 17 and 29 months. For the remaining 23 resected patients, 15 of 23 (65%) showed tumor regression grade 3 response, and 7 of 23 (30%) had pathologic complete response; 8 (35%) and 12 (52%) tumor regression grade 3 patients had ≤5% and 10% residual viable cells, respectively. Conclusions: An adaptive boost strategy is feasible, with an acceptable grade 3 gastrointestinal toxicity rate and a very encouraging tumor response rate. The results suggest that there should still be room for further dose escalation of the residual tumor with the aim of increasing pathologic complete response and/or cCR rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase-field modeling of diffusion bonding in 316H stainless steel: Impact of processing conditions on grain morphology and bonding quality

A novel multi-phase, multi-component phase‐field model is presented to study the diffusion bonding of 316H stainless steel. Combined with targeted experimental investigations, this model simulates the bond-growth process and predicts the bonding quality. Unlike previous models, our approach captures the simultaneous evolution of voids and grain structures, while quantifying bonding quality using defined bonding ratio. A comprehensive analysis of bond process control is performed by changing temperature, pressure and surface roughness observing the resulting bond structure, which is consistent with experimental observations and analytical predictions. Temperature is determined to be the dominant factor, with the transition from a flat to a robust bond occurring between 1000 °C and 1050 °C. At the ideal bonding temperature of 1050 °C, a surface roughness exceeding 0.6 μm or an applied stress below 4 MPa results in poor bonding quality. Beyond this, higher pressures and smoother surfaces reduce void size, accelerate void shrinkage, and lead to improved bond integrity. This diffuse-interface model can be extended to other material systems if supplied with appropriate thermodynamic and kinetic data. In conclusion, this makes it an effective modeling platform for optimizing high-temperature diffusion bonding and developing reliable bonded components such as compact heat exchangers.

Diffusion bonding↗