Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thick Target”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54

CdS Film Thickness Characterization By R. F. Magnetron Sputtering

In this work, cadmium sulphide (CdS) target with 99.999% purity was used as a target in RF magnetron sputtering. The sputtering experiment was conducted onto silicon oxide substrates at different temperatures ranging from 200 deg. C to 400 deg. C in 50 deg. C steps, using a capacitive coupled magnetron cathode with 13.65 MHz that at higher magnetron power. After all investigations, it was concluded that 300 deg. C substrate temperature is suitable for producing CdS films on silicon wafer with RF magnetron sputtering and the examined properties (good crystallinity and low resistivity) of this film show its feasibility for technological purposes, especially for light sensor cells.

36 MATERIALS SCIENCE↗

Study of hypervelocity projectile impact on thick metal plates

Hypervelocity impacts generate extreme pressure and shock waves in impacted targets that undergo severe localized deformation within a few microseconds. These impact experiments pose unique challenges in terms of obtaining accurate measurements. Similarly, simulating these experiments is not straightforward. This paper proposed an approach to experimentally measure the velocity of the back surface of an A36 steel plate impacted by a projectile. All experiments used a combination of a two-stage light-gas gun and the photonic Doppler velocimetry (PDV) technique. The experimental data were used to benchmark and verify computational studies. Two different finite-element methods were used to simulate the experiments: Lagrangian-based smooth particle hydrodynamics (SPH) and Eulerian-based hydrocode. Both codes used the Johnson-Cook material model and the Mie-Grüneisen equation of state. Experiments and simulations were compared based on the physical damage area and the back surface velocity. Finally, the results of this study showed that the proposed simulation approaches could be used to reduce the need for expensive experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-19: A New End-To-End Test Method for ExacTrac for Radiation and Plan Isocenter Congruence

Purpose: To combine and integrate quality assurance (QA) of target localization and radiation isocenter End to End (E2E) test of BrainLAB ExacTrac system, a new QA approach was devised using anthropomorphic head and neck phantom. This test insures the target localization as well as radiation isocenter congruence which is one step ahead the current ExacTrac QA procedures. Methods: The head and neck phantom typically used for CyberKnife E2E test was irradiated to the sphere target that was visible in CT-sim images. The CT-sim was performed using 1 mm thickness slice with helical scanning technique. The size of the sphere was 3-cm diameter and contoured as a target volume using iPlan V.4.5.2. A conformal arc plan was generated using MLC-based with 7 fields, and five of them were include couch rotations. The prescription dose was 5 Gy and 95% coverage to the target volume. For the irradiation, two Gafchromic films were perpendicularly inserted into the cube that hold sphere inside. The linac used for the irradiation was TrueBeam STx equipped with HD120 MLC. In order to use ExacTrac, infra-red head–array was used to correlate orthogonal X-ray images. Results: Using orthogonal X-rays of ExacTrac the phantom was positioned. For each field, phantom was check again with X-rays and re-positioned if necessary. After each setup using ExacTrac, the target was irradiated. The films were analyzed to determine the deviation of the radiation isocenter in all three dimensions: superior-inferior, left-right and anterior-posterior. The total combining error was found to be 0.76 mm ± 0.05 mm which was within sub-millimeter accuracy. Conclusion: Until now, E2E test for ExacTrac was separately implemented to test image localization and radiation isocenter. This new method can be used for periodic QA procedures.

60 APPLIED LIFE SCIENCES↗

Component with inspection-facilitating features

A turbine airfoil can be formed with features to facilitate measurement of its wall thickness. An outer wall of the airfoil can include an outer surface and an inner surface. The outer surface of the airfoil can have an outer inspection target surface, and the inner surface of the airfoil can have an inner inspection target surface. The inner and outer target surfaces can define substantially flat regions in surfaces that are otherwise highly contoured. The inner and outer inspection target surfaces can be substantially aligned with each other. The inner and outer target surfaces can be substantially parallel to each other. As a result of these arrangements, a highly accurate measurement of wall thickness can be obtained. In one embodiment, the outer inspection target surface can be defined by an innermost surface of a groove formed in the outer surface of the outer wall of the airfoil.

42 ENGINEERING↗

Thermohydraulic Design Analysis of the Target Assembly in the Material Plasma Exposure Experiment Facility

The Material Plasma Exposure eXperiment (MPEX) project seeks to design a steady-state linear plasma facility at Oak Ridge National Laboratory that will be used to study plasma-material interactions (PMIs) at fusion prototypic levels, supporting the evaluation and development of materials for the next generation of fusion devices. This study is focused on PMI exposure of small-size neutron-irradiated specimens, which are clamped onto an actively cooled component. A thermohydraulic evaluation of a new MPEX target assembly design to assess the appropriate operation during MPEX operation is presented. To further guide the design and assess the structural integrity of the components under expected loads, preliminary thermomechanical stress analyses were also conducted. To ensure good thermal contact between the components, thermal interface materials, such as silver flexible graphite, were used in the assembly. It was found that the maximum target temperatures of 1572, 1463, and 1315 K were obtained for Grafoil thicknesses of 0.61, 0.38, and 0.25 mm, respectively. The distribution of the axial deformation at high heat fluxes showed that there are no gaps between components, indicating good contact at material interfaces. Moreover, the contact pressure between the target and other components indicated that very good contact was established at these interfaces. Furthermore, the stress-strain conditions for the target will be further used to assess the appropriate operation during MPEX experiments and gain insight into materials science phenomena during PMI experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Major Element Analysis of the Target Rocks at Meteor Crater, Arizona

We collected approximately 400 rock chips in continuous vertical profile at Meteor Crater, Arizona, representing, from bottom to top, the Coconino, Toroweap, Kaibab, and Moenkopi Formations to support ongoing compositional analyses of the impact melts and their stratigraphic source depth(s) and other studies at Meteor Crater that depend on the composition of the target rocks. These rock chips were subsequently pooled into 23 samples for compositional analysis by XRF (x ray fluorescence) methods, each sample reflecting a specific stratigraphic "subsection" approximately 5-10 in thick. We determined the modal abundance of quartz, dolomite, and calcite for the entire Kaibab Formation at vertical resolutions of 1-2 meters. The Coconino Formation composes the lower half of the crater cavity. It is an exceptionally pure sandstone. The Toroweap is only two inches thick and compositionally similar to Coconino, therefore, it is not a good compositional marker horizon. The Kaibab Formation is approximately 80 in thick. XRD (x ray diffraction) studies show that the Kaibab Formation is dominated by dolomite and quartz, albeit in highly variable proportions; calcite is a minor phase at best. The Kaibab at Meteor Crater is therefore a sandy dolomite rather than a limestone, consistent with pronounced facies changes in the Permian of SE Arizona over short vertical and horizontal distances. The Moenkopi forms the 12 in thick cap rock and has the highest Al2O3 and FeO concentrations of all target rocks. With several examples, we illustrate how this systematic compositional and modal characterization of the target ideologies may contribute to an understanding of Meteor Crater, such as the depth of its melt zone, and to impact cratering in general, such as the liberation of CO2 from shocked carbonates.

See, Thomas H.↗

A high yield neutron target

Target, in cylinder form, rotates rapidly in front of beam. Titanium tritide film is much thicker than range of accelerated deutron. Sputtering electrode permits full use of thick film. Stream of high-velocity coolant provides efficient transfer of heat from target.

Alger, D. L.↗

High gas-pressure apparatus for nonlinear X-ray propagation and reshaping via stimulated X-ray Raman scattering

Abstract We describe an experimental setup for non-linear interaction and propagation of ultrashort and intense x-ray free-electron laser (XFEL) pulses in a dense gas. It allows one to provide high, but adjustable, target-gas pressures of up to 6 bar within a vacuum environment of 3∙10 − 3 mbar or better. The setup enables investigation of intense x-ray propagation in an optically thick medium with minimal absorption loss of the unfocused beam outside of the target. As an application, we demonstrate the amplification of spectrally-resolved stimulated x-ray Raman scattering (SXRS) in dense neon gas, where the most intense inner part of the beam is almost completely absorbed. As a result, in the inner part of the beam, the SXRS signal exceeds the residual XFEL pulse by a factor of around two. In principle, this reshaping effect allows for a spatial separation of the two spectral components, i.e., the driving pulse and the SXRS signal.

Magunia, Alexander↗

Binary pseudo-random array standard for extreme ultraviolet lithography tool characterization

Extreme ultraviolet (EUV) imaging tools play a crucial role in EUV lithography. Achieving high accuracy in EUV metrology is essential for advanced semiconductor manufacturing. A thorough characterization of the instrumentation in use is required. Binary pseudo-random arrays (BPRAs) are an established standard for calibrating and characterizing optical instruments in the frequency domain. Here, we expand the BPRA standard to applications in EUV imaging. To extend the technology to the EUV spectral range, a high-resolution BPRA target with the smallest feature size of 40 nm is developed. The EUV BPRA target establishes an in situ and portable calibration and alignment standard for EUV imaging. The target is patterned by means of electron-beam lithography, using a nickel absorber with a thickness of 39 nm. The substrate is a 4″ silicon wafer with a molybdenum/silicon multilayer coating. To demonstrate the efficacy of the target and develop the instrument calibration protocol, the target is imaged on the Sharp Hyper-NA Actinic Reticle Review Project EUV mask microscope. Power spectral density (PSD) data are presented. The characteristics of the imaging system are imprinted on the PSD. The modulation transfer function is extracted from the PSD data. A partially coherent imaging model is used as a reference to the experimental results.

BPRA↗

Laser-driven flyer plates for shock compression science: Launch and target impact probed by photon Doppler velocimetry

We investigated the launch and target impact of laser-driven Al flyer plates using photon Doppler velocimetry (PDV). We studied different flyer designs launched by laser pulses of different energies, pulse durations and beam diameters, that produced km s{sup −1} impacts with transparent target materials. Laser-launching Al flyers 25–100 μm thick cemented to glass substrates is usually thought to involve laser vaporization of a portion of the flyer, which creates many difficulties associated with loss of integrity and heating of the flyer material. However, in the system used here, the launch mechanism was surprising and unexpected: it involved optical damage at the glass/cement/flyer interface, with very little laser light reaching the flyer itself. In fact the flyers launched in this manner behaved almost identically to multilayer flyers that were optically shielded from the laser pulses and insulated from heat generated by the pulses. Launching flyers with nanosecond laser pulses creates undesirable reverberating shocks in the flyer. In some cases, with 10 ns launch pulses, the thickest flyers were observed to lose integrity. But with stretched 20 ns pulses, we showed that the reverberations damped out prior to impact with targets, and that the flyers maintained their integrity during flight. Flyer impacts with salt, glass, fused silica, and acrylic polymer were studied by PDV, and the durations of fully supported shocks in those media were determined, and could be varied from 5 to 23 ns.

36 MATERIALS SCIENCE↗

Use of High-Frequency Jet Ventilation for Percutaneous Tumor Ablation

Purpose: To report feasibility and potential benefits of high-frequency jet ventilation (HFJV) in tumor ablations techniques in liver, kidney, and lung lesions. Methods: This prospective study included 51 patients (14 women, mean age 66 years) bearing 66 tumors (56 hepatic, 5 pulmonary, 5 renal tumors) with a median size of 16 ± 8.7 mm, referred for tumor ablation in an intention-to-treat fashion before preoperative anesthesiology visit. Cancellation and complications of HFJV were prospectively recorded. Anesthesia and procedure duration, as well as mean CO{sub 2} capnea, were recorded. When computed tomography guidance was used, 3D spacial coordinates of an anatomical target <2 mm in diameter on 8 slabs of 4 slices of 3.75-mm slice thickness were registered. Results: HFJV was used in 41 of 51 patients. Of the ten patients who were not candidate for HFJV, two patients had contraindication to HFJV (severe COPD), three had lesions invisible under HFJV requiring deep inspiration apnea for tumor targeting, and five patients could not have HFJV because of unavailability of a trained anesthetic team. No specific complication or hypercapnia related to HFJV were observed despite a mean anesthetic duration of 2 h and ventilation performed in procubitus (n = 4) or lateral decubitus (n = 6). Measured internal target movement was 0.3 mm in x- and y-axis and below the slice thickness of 3.75 mm in the z-axis in 11 patients. Conclusions: HFJV is feasible in 80 % of patients allowing for near immobility of internal organs during liver, kidney, and lung tumor ablation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Direct measurement of {sup 4}He({sup 12}C, {sup 16}O){gamma} reaction near stellar energy

A cross section measurement with a direct {sup 16}O detection method for the reaction energy from E{sub cm} = 2.4 down to 0.7 MeV is planned at Kyushu University Tandem Laboratory (KUTL). To perform the experiment successfully and to get the quantitative information of the cross section within the 10% error, we have newly developed several instruments in 2009, such as a blow-in type windowless gas target and movable slit system placed in the recoil mass separator. By using the windowless blow-in gas target, a pressure of 24 Torr was achieved. The effective thickness along the beam axis was measured by p+{sup 4}He scattering. Thanks to the movable slits installed in a recoil mass separator and the trajectory analysis, we found effective reduction of background conditions from the {sup 12}C beam.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effects of target fragmentation on evaluation of LET spectra from space radiation in low-earth orbit (LEO) environment: impact on SEU predictions

Recent improvements in the radiation transport code HZETRN/BRYNTRN and galactic cosmic ray environmental model have provided an opportunity to investigate the effects of target fragmentation on estimates of single event upset (SEU) rates for spacecraft memory devices. Since target fragments are mostly of very low energy, an SEU prediction model has been derived in terms of particle energy rather than linear energy transfer (LET) to account for nonlinear relationship between range and energy. Predictions are made for SEU rates observed on two Shuttle flights, each at low and high inclination orbit. Corrections due to track structure effects are made for both high energy ions with track structure larger than device sensitive volume and for low energy ions with dense track where charge recombination is important. Results indicate contributions from target fragments are relatively important at large shield depths (or any thick structure material) and at low inclination orbit. Consequently, a more consistent set of predictions for upset rates observed in these two flights is reached when compared to an earlier analysis with CREME model. It is also observed that the errors produced by assuming linear relationship in range and energy in the earlier analysis have fortuitously canceled out the errors for not considering target fragmentation and track structure effects.

STS-51 Shuttle Project↗

Effects of Target Fragmentation on Evaluation of LET Spectra From Space Radiation in Low-Earth Orbit (LEO) Environment: Impact on SEU Predictions

Recent improvements in the radiation transport code HZETRN/BRYNTRN and galactic cosmic ray environmental model have provided an opportunity to investigate the effects of target fragmentation on estimates of single event upset (SEU) rates for spacecraft memory devices. Since target fragments are mostly of very low energy, an SEU prediction model has been derived in terms of particle energy rather than linear energy transfer (LET) to account for nonlinear relationship between range and energy. Predictions are made for SEU rates observed on two Shuttle flights, each at low and high inclination orbit. Corrections due to track structure effects are made for both high energy ions with track structure larger than device sensitive volume and for low energy ions with dense track where charge recombination is important. Results indicate contributions from target fragments are relatively important at large shield depths (or any thick structure material) and at low inclination orbit. Consequently, a more consistent set of predictions for upset rates observed in these two flights is reached when compared to an earlier analysis with CREME model. It is also observed that the errors produced by assuming linear relationship in range and energy in the earlier analysis have fortuitously canceled out the errors for not considering target fragmentation and track structure effects.

Shinn, J. L.↗

A Multi-institutional Clinical Trial of Rectal Dose Reduction via Injected Polyethylene-Glycol Hydrogel During Intensity Modulated Radiation Therapy for Prostate Cancer: Analysis of Dosimetric Outcomes

Purpose: To characterize the effect of a prostate-rectum spacer on dose to rectum during external beam radiation therapy for prostate cancer and to assess for factors correlated with rectal dose reduction. Methods and Materials: Fifty-two patients at 4 institutions were enrolled into a prospective pilot clinical trial. Patients underwent baseline scans and then were injected with perirectal spacing hydrogel and rescanned. Intensity modulated radiation therapy plans were created on both scans for comparison. The objectives were to establish rates of creation of ≥7.5 mm of prostate-rectal separation, and decrease in rectal V70 of ≥25%. Multiple regression analysis was performed to evaluate the associations between preinjection and postinjection changes in rectal V70 and changes in plan conformity, rectal volume, bladder volume, bladder V70, planning target volume (PTV), and postinjection midgland separation, gel volume, gel thickness, length of PTV/gel contact, and gel left-to-right symmetry. Results: Hydrogel resulted in ≥7.5-mm prostate-rectal separation in 95.8% of patients; 95.7% had decreased rectal V70 of ≥25%, with a mean reduction of 8.0 Gy. There were no significant differences in preinjection and postinjection prostate, PTV, rectal, and bladder volumes. Plan conformities were significantly different before versus after injection (P=.02); plans with worse conformity indexes after injection compared with before injection (n=13) still had improvements in rectal V70. In multiple regression analysis, greater postinjection reduction in V70 was associated with decreased relative postinjection plan conformity (P=.01). Reductions in V70 did not significantly vary by institution, despite significant interinstitutional variations in plan conformity. There were no significant relationships between reduction in V70 and the other characteristics analyzed. Conclusions: Injection of hydrogel into the prostate-rectal interface resulted in dose reductions to rectum for >90% of patients treated. Rectal sparing was statistically significant across a range of 10 to 75 Gy and was demonstrated within the presence of significant interinstitutional variability in plan conformity, target definitions, and injection results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

3 MW Solid Rotating Target Design

A rotating solid target design concept is being developed for potential use at the second SNS target station (STS). A long pulse beam (~ 1 msec) at 1.3 GeV and 20 Hz is planned with power levels at or above 1 MW. Since the long pulse may give future opportunities for higher power, this study is looking at 3 MW to compare the performance of a solid rotating target to a mercury target. Unlike the case for stationary solid targets at such powers this study indicates that a rotating solid target, when used with large coupled hydrogen moderators, has neutronic performance equal to or better than that with a mercury target, and the solid target has a greatly increased lifetime. Design studies have investigated water cooled tungsten targets with tantalum cladding approximately 1.2 m in diameter, and 70mm thick. Operating temperatures are low ( < 150 C) with mid-plane, top and bottom surface cooling. In case of cooling system failure, the diameter gives enough surface area to remove the decay heat by radiation to the surrounding reflector assemblies while keeping the peak temperatures below approximately 700 C. This temperature should mitigate potential loss of coolant accidents and subsequent steam, tungsten interaction which has a threshold of approximately 800 C. Design layouts for the sealing systems and potential target station concepts have been developed.

rotating target↗

Intrinsic even-odd thickness-driven anomalous Hall effect in epitaxial MnBi2⁢Te4 thin films

We demonstrate precise control of magnetism in MnBi2⁢Te4 thin films through careful synthesis by molecular beam epitaxy, achieving minimal defects and accurate layer thickness control. By optimizing Mn-Bi-Te ratios and growth temperatures, we minimize detrimental self-doping effects and accurately target integer-layer films. X-ray diffraction and reflectivity provide quantitative measures of film quality and thickness. When these macroscale probes of structure and thickness are integrated with magnetotransport measurements, a striking even-odd layer dependence of the anomalous Hall effect is revealed. Odd-layer films exhibit a large hysteresis up to the Néel temperature (∼25K), consistent with noncompensated antiferromagnetism, while even-layer films show minimal response, as expected for an antiferromagnet. The sign of the anomalous Hall effect exhibits a sign reversal for intrinsic magnetism versus magnetism associated with defects. This work identifies critical factors for inducing pure, noncompensated ferromagnetism and reveals the characteristics of the intrinsic anomalous Hall effect in MnBi2⁢Te4, which together is a step toward realizing the zero-field quantum anomalous Hall effect in topological materials.

Mallick, Deb [ORNL] (ORCID:000900005806411X)↗